UC Berkeley UC Berkeley Electronic Theses and Dissertations UC Berkeley UC Berkeley Electronic Theses and Dissertations Title Advanced Organic Vapor Cycles for Improving Thermal Conversion Efficiency in Renewable Energy Systems Permalink https://escholarship.org/uc/item/9s08s4js Author Ho, Tony Publication Date 2012 Peer reviewed|Thesis/dissertation eScholarship.org Powered by the California Digital Library University of California Advanced Organic Vapor Cycles for Improving Thermal Conversion Efficiency in Renewable Energy Systems By Tony Ho A dissertation submitted in partial satisfaction of the requirements for the degree of Doctor of Philosophy in Engineering – Mechanical Engineering in the Graduate Division of the University of California, Berkeley Committee in charge: Professor Ralph Greif, Co-Chair Professor Samuel S. Mao, Co-Chair Professor Van P. Carey Professor Per F. Peterson Spring 2012 Abstract Advanced Organic Vapor Cycles for Improving Thermal Conversion Efficiency in Renewable Energy Systems by Tony Ho Doctor of Philosophy in Mechanical Engineering University of California, Berkeley Professor Ralph Greif, Co-Chair Professor Samuel S. Mao, Co-Chair The Organic Flash Cycle (OFC) is proposed as a vapor power cycle that could potentially increase power generation and improve the utilization efficiency of renewable energy and waste heat recovery systems. A brief review of current advanced vapor power cycles including the Organic Rankine Cycle (ORC), the zeotropic Rankine cycle, the Kalina cycle, the transcritical cycle, and the trilateral flash cycle is presented. The premise and motivation for the OFC concept is that essentially by improving temperature matching to the energy reservoir stream during heat addition to the power cycle, less irreversibilities are generated and more power can be produced from a given finite thermal energy reservoir. In this study, modern equations of state explicit in Helmholtz energy such as the BACKONE equations, multi-parameter Span- Wagner equations, and the equations compiled in NIST REFPROP 8.0 were used to accurately determine thermodynamic property data for the working fluids considered. Though these equations of state tend to be significantly more complex than cubic equations both in form and computational schemes, modern Helmholtz equations provide much higher accuracy in the high pressure regions, liquid regions, and two-phase regions and also can be extended to accurately describe complex polar fluids. Calculated values of saturated liquid and vapor density and vapor pressure were then compared to values listed in the NIST Chemistry WebBook to ensure accuracy for the temperature range of interest. Deviations from the NIST WebBook were typically below 1%; a comparison of first law efficiencies for an ideal basic Rankine cycle yielded less than 0.4% difference between calculations using the Helmholtz-explicit equations of state and NIST REFPROP. Also by employing the BACKONE and Span-Wagner equations, the number of potential aromatic hydrocarbon and siloxane working fluids that are appropriate for high and intermediate temperature applications is expanded considerably. A theoretical investigation on the OFC is conducted using the aforementioned Helmholtz- explicit equations of state for 10 different aromatic hydrocarbon and siloxane working fluids for intermediate temperature finite thermal energy reservoirs (~300oC). Results showed that aromatic hydrocarbons to be the better suited working fluid for the ORC and OFC due to less “drying” behavior and also smaller turbine volumetric flow ratios resulting in simpler turbine designs. The single flash OFC is shown to achieve utilization efficiencies that are comparable to 1 the optimized basic ORC (~0.63) which is used as a baseline. It is shown that the advantage of improved temperature matching during heat addition was effectively negated by irreversibilities introduced into the OFC during flash evaporation. Several improvements to the basic OFC are proposed and analyzed such as introducing a secondary flash stage or replacing the throttling valve with a two-phase expander. Utilization efficiency gains of about 10% over the optimized basic ORC can be achieved by splitting the expansion process in the OFC into two steps and recombining the liquid stream from flash evaporation prior to the secondary, low pressure, expansion stage. Results show that the proposed enhancements had a more pronounced effect for the OFC using aromatic hydrocarbon working fluids (5-20% utilization efficiency improvement) than for siloxane working fluids (2-4%). The proposed modifications were aimed towards reducing irreversibility in flash evaporation; it was observed for siloxanes that the primary source of irreversibility was due to high superheat at the turbine exhaust because of the highly “drying” nature of the fluid. Though an order of magnitude analysis, results showed that the OFC and ORC to require similar heat transfer surface areas. For low temperature thermal energy reservoirs (80-150oC) applicable to non-concentrated solar thermal, geothermal, and low grade industrial waste heat energy, alkane and refrigerant working fluids possess more appropriate vapor pressures. The optimized single flash OFC was again shown to generate comparable power per unit flow rate of the thermal energy reservoir than the optimized basic ORC. With some of the previously proposed design modifications though, the OFC can produce over 60% more power than the optimized ORC. For low temperature applications, the minimum temperature difference between streams in the heat exchanger, or pinch temperature, becomes an important design parameter. Reduction of the pinch temperature even slightly can yield significantly higher gains in power output, but will also increase required heat exchanger surface area and subsequently capital costs. A high-level design of a liquid-fluoride salt (NaF-NaBF4) cooled solar power tower plant is presented; liquid-fluoride salt is used rather than current molten nitrate salts to increase the receiver temperature and subsequently allow for higher efficiency gas power cycles to be used. Graphite or direct energy storage in the salt itself is proposed. The power block component of this heliostat-central receiver plant is a combined cycle system consisting of a topping Brayton cycle with intercooling, reheat, and regeneration and a bottoming low-temperature modified OFC. The combined cycle is designed with dry cooling in mind, such that operation in desert climates are more suitable. The combined cycle design is shown to increase power block efficiencies by 6%-8% over the Brayton cycle with intercooling, reheat, and regeneration alone. An estimated 30% annual average total solar-to-electric conversion efficiency is possible with this system design, which is comparable to some of the most efficient high temperature solar power tower designs to date. Theoretically, power block efficiencies over 60% are possible; however, emission losses from the isothermal central receiver would limit the plant’s operational temperature range. Results show that for high efficiency solar power towers to be realized, high temperature non-isothermal, or partitioned, receivers operating efficiently above 1000oC are necessary. Other potential areas of renewable energy system integration for the OFC include a co-generation solar thermal-photovoltaic system that employs highly concentrated, densely packed photovoltaic cells using single-phase or two-phase cooling. The thermal energy absorbed by that coolant could then be used as the working fluid in a separate OFC to further produce power in co-generation with the concentrated photovoltaics. 2 Dedication This dissertation is dedicated to my mother and father, Tracy and Yick Han Ho; I owe everything to their love, their hard work and sacrifices, and the character that they have instilled in me. This dissertation is also dedicated in loving memory of my grandfather. i Table of Contents Abstract ........................................................................................................................................... 1 Dedication ........................................................................................................................................ i List of Figures ................................................................................................................................. v List of Tables ................................................................................................................................. ix Nomenclature .................................................................................................................................. x Acknowledgements ...................................................................................................................... xiii 1 Introduction ............................................................................................................................. 1 1.1 Background on thermal energy conversion systems ........................................................ 1 1.2 Review of advanced vapor power cycles for finite thermal sources ................................ 3 1.2.1 Steam Rankine cycle ................................................................................................. 3 1.2.2 Organic Rankine Cycles (ORC)................................................................................ 5 1.2.3 Zeotropic vapor cycles ............................................................................................ 10 1.2.4 Transcritical
Recommended publications
  • Performance Analysis of Two-Stage Transcritical Refrigeration Cycle Operating with R744
    Proceedings of COBEM 2011 21 st Brazilian Congress of Mechanical Engineering Copyright © 2011 by ABCM October 24-28, 2011, Natal, RN, Brazil PERFORMANCE ANALYSIS OF TWO-STAGE TRANSCRITICAL REFRIGERATION CYCLE OPERATING WITH R744 Igor Marcel Gomes Almeida, [email protected] Studies Group in Refrigeration and Air-Conditioning. Federal Institute of Education, Science and Technology of Rio Grande do Norte. Santa Cruz-RN. Cleiton Rubens Formiga Barbosa, [email protected] Francisco de Assis Oliveira Fontes, [email protected] Federal University of Rio Grande do Norte. Department of Mechanical Engineering. Abstract. The present study is a theoretical analysis of a two-stage transcritical cooling cycle using R744 (carbon dioxide) as a refrigerant. The effect of the intercooling process on performance in the two-stage transcritical system is subjected to varying pressures in a gas cooler. Performance comparison between the single stage and two-stage cycle is also subject to the same operating conditions. We assessed the effects on system performance of pressure in the gas cooler, isentropic compressor efficiency, amount of intercooling between the two compression stages and discharge temperature of the refrigerant from the gas cooler. Thermodynamic analysis was carried out with CoolPack software, considering an evaporation temperature of -10 oC and refrigeration capacity of 5 kW. Results show the coefficient of performance (COP) for the two-stage cycle is superior to the single stage cycle. Two-stage compression was found to reduce energy consumption. On the whole, two-stage compression and the intercooling process are significant in increasing COP for these systems. Keywords : Natural refrigerants, Carbon dioxide, Performance, Two-stage compression, Transcritical cycle.
    [Show full text]
  • Performance Comparison of Different Rankine Cycle Technologies Applied to Low and Medium Temperature Industrial Surplus Heat Scenarios
    Paper ID: 175 Page 1 Performance Comparison of Different Rankine Cycle Technologies Applied to Low and Medium Temperature Industrial Surplus Heat Scenarios Goran Durakovic1*, Monika Nikolaisen2 SINTEF Energy Research, Gas technology, Trondheim, Norway [email protected] [email protected] * Corresponding Author ABSTRACT Energy intensive industries generate vast amounts of low-grade surplus heat, and potential for direct re- use can be limited due to insufficient local demand. Conversion of heat into electric power thus becomes an attractive option. However, heat-to-power conversion is limited by poor efficiencies for heat sources at low and medium temperatures. To optimally utilize the available energy, the choice of technology could be important. In this work, single-stage subcritical, dual-stage subcritical and single-stage transcritical Rankine cycle technologies were compared. The investigated heat sources are an air equivalent off-gas at 150°C and 200°C and a liquid heat source at 150°C. These were all evaluated with the same available duty. The Rankine cycles were compared with equal total heat exchanger areas to enable fair comparisons of different cycles, instead of comparing cycles based on equal pinch point temperature differences as is frequently reported in literature. Six working fluids were investigated for both heat source temperatures, and cycle optimization was performed to determine the best Rankine cycle for each working fluid. This means that the optimizer could choose between single-stage and dual-stage cycle during one optimization, and determine which gave the highest net power output. The results were benchmarked against single-stage subcritical Rankine cycles. The results showed that the cycle yielding the highest net power varied depending on the allowable total heat exchanger area.
    [Show full text]
  • Thermodynamic Optimization of an Organic Rankine Cycle for Power Generation from a Low Temperature Geothermal Heat Source
    Thermodynamic Optimization of an Organic Rankine Cycle for Power Generation from a Low Temperature Geothermal Heat Source Inés Encabo Cáceres Roberto Agromayor Lars O. Nord Department of Energy and Process Engineering Norwegian University of Science and Technology (NTNU) Kolbjørn Hejes v.1B, NO-7491 Trondheim, Norway [email protected] Abstract fueled by natural gas or other fossil fuels (Macchi and Astolfi, 2017). However, during the last years, the The increasing concern on environment problems has increasing concern of the greenhouse effect and climate led to the development of renewable energy sources, change has led to an increase of renewable energy, such being the geothermal energy one of the most promising as wind and solar power. In addition to these listed ones in terms of power generation. Due to the low heat renewable energies, there is an energy source that shows source temperatures this energy provides, the use of a promising future due to the advantages it provides Organic Rankine Cycles is necessary to guarantee a when compared to other renewable energies. This good performance of the system. In this paper, the developing energy is geothermal energy, and its optimization of an Organic Rankine Cycle has been advantages are related to its availability (Macchi and carried out to determine the most suitable working fluid. Astolfi, 2017): it does not depend on the ambient Different cycle layouts and configurations for 39 conditions, it is stable, and it offers the possibility of different working fluids were simulated by means of a renewable energy base load operation. One of the Gradient Based Optimization Algorithm implemented challenges of geothermal energy is that it does not in MATLAB and linked to REFPROP property library.
    [Show full text]
  • Transcritical Pressure Organic Rankine Cycle (ORC) Analysis Based on the Integrated-Average Temperature Difference in Evaporators
    Applied Thermal Engineering 88 (2015) 2e13 Contents lists available at ScienceDirect Applied Thermal Engineering journal homepage: www.elsevier.com/locate/apthermeng Research paper Transcritical pressure Organic Rankine Cycle (ORC) analysis based on the integrated-average temperature difference in evaporators * Chao Yu, Jinliang Xu , Yasong Sun The Beijing Key Laboratory of Multiphase Flow and Heat Transfer for Low Grade Energy Utilizations, North China Electric Power University, Beijing 102206, PR China article info abstract Article history: Integrated-average temperature difference (DTave) was proposed to connect with exergy destruction (Ieva) Received 24 June 2014 in heat exchangers. Theoretical expressions were developed for DTave and Ieva. Based on transcritical Received in revised form pressure ORCs, evaporators were theoretically studied regarding DTave. An exact linear relationship be- 12 October 2014 tween DT and I was identified. The increased specific heats versus temperatures for organic fluid Accepted 11 November 2014 ave eva protruded its TeQ curve to decrease DT . Meanwhile, the decreased specific heats concaved its TeQ Available online 20 November 2014 ave curve to raise DTave. Organic fluid in the evaporator undergoes a protruded TeQ curve and a concaved T eQ curve, interfaced at the pseudo-critical temperature point. Elongating the specific heat increment Keywords: fi Organic Rankine Cycle section and shortening the speci c heat decrease section improved the cycle performance. Thus, the fi Integrated-average temperature difference system thermal and exergy ef ciencies were increased by increasing critical temperatures for 25 organic Exergy destruction fluids. Wet fluids had larger thermal and exergy efficiencies than dry fluids, due to the fact that wet fluids Thermal match shortened the superheated vapor flow section in condensers.
    [Show full text]
  • Advanced Organic Vapor Cycles for Improving Thermal Conversion Efficiency in Renewable Energy Systems by Tony Ho a Dissertation
    Advanced Organic Vapor Cycles for Improving Thermal Conversion Efficiency in Renewable Energy Systems By Tony Ho A dissertation submitted in partial satisfaction of the requirements for the degree of Doctor of Philosophy in Engineering – Mechanical Engineering in the Graduate Division of the University of California, Berkeley Committee in charge: Professor Ralph Greif, Co-Chair Professor Samuel S. Mao, Co-Chair Professor Van P. Carey Professor Per F. Peterson Spring 2012 Abstract Advanced Organic Vapor Cycles for Improving Thermal Conversion Efficiency in Renewable Energy Systems by Tony Ho Doctor of Philosophy in Mechanical Engineering University of California, Berkeley Professor Ralph Greif, Co-Chair Professor Samuel S. Mao, Co-Chair The Organic Flash Cycle (OFC) is proposed as a vapor power cycle that could potentially increase power generation and improve the utilization efficiency of renewable energy and waste heat recovery systems. A brief review of current advanced vapor power cycles including the Organic Rankine Cycle (ORC), the zeotropic Rankine cycle, the Kalina cycle, the transcritical cycle, and the trilateral flash cycle is presented. The premise and motivation for the OFC concept is that essentially by improving temperature matching to the energy reservoir stream during heat addition to the power cycle, less irreversibilities are generated and more power can be produced from a given finite thermal energy reservoir. In this study, modern equations of state explicit in Helmholtz energy such as the BACKONE equations, multi-parameter Span- Wagner equations, and the equations compiled in NIST REFPROP 8.0 were used to accurately determine thermodynamic property data for the working fluids considered. Though these equations of state tend to be significantly more complex than cubic equations both in form and computational schemes, modern Helmholtz equations provide much higher accuracy in the high pressure regions, liquid regions, and two-phase regions and also can be extended to accurately describe complex polar fluids.
    [Show full text]
  • Analysis of a CO2 Transcritical Refrigeration Cycle with a Vortex Tube Expansion
    sustainability Article Analysis of a CO2 Transcritical Refrigeration Cycle with a Vortex Tube Expansion Yefeng Liu *, Ying Sun and Danping Tang University of Shanghai for Science and Technology, Shanghai 200093, China; [email protected] (Y.S.); [email protected] (D.T.) * Correspondence: [email protected]; Tel.: +86-21-55272320; Fax: +86-21-55272376 Received: 25 January 2019; Accepted: 19 March 2019; Published: 4 April 2019 Abstract: A carbon dioxide (CO2) refrigeration system in a transcritical cycle requires modifications to improve the coefficient of performance (COP) for energy saving. This modification has become more important with the system’s more and more widely used applications in heat pump water heaters, automotive air conditioning, and space heating. In this paper, a single vortex tube is proposed to replace the expansion valve of a traditional CO2 transcritical refrigeration system to reduce irreversible loss and improve the COP. The principle of the proposed system is introduced and analyzed: Its mathematical model was developed to simulate and compare the system performance to the traditional system. The results showed that the proposed system could save energy, and the vortex tube inlet temperature and discharge pressure had significant impacts on COP improvement. When the vortex tube inlet temperature was 45 ◦C, and the discharge pressure was 9 MPa, the COP increased 33.7%. When the isentropic efficiency or cold mass fraction of the vortex tube increased, the COP increased about 10%. When the evaporation temperature or the cooling water inlet temperature of the desuperheater decreased, the COP also could increase about 10%. The optimal discharge pressure correlation of the proposed system was established, and its influences on COP improvement are discussed.
    [Show full text]
  • Sustainable Energy Conversion Through the Use of Organic Rankine Cycles for Waste Heat Recovery and Solar Applications
    ENERGY SYSTEMS RESEARCH UNIT AEROSPACE AND MECHANICAL ENGINEERING DEPARTMENT UNIVERSITY OF LIÈGE Sustainable Energy Conversion Through the Use of Organic Rankine Cycles for Waste Heat Recovery and Solar Applications. in Partial Fulfillment of the Requirements for the Degree of Doctor of Applied Sciences Presented to the Faculty of Applied Science of the University of Liège (Belgium) by Sylvain Quoilin Liège, October 2011 Introductory remarks Version 1.1, published in October 2011 © 2011 Sylvain Quoilin 〈►[email protected]〉 Licence. This work is licensed under the Creative Commons Attribution - No Derivative Works 2.5 License. To view a copy of this license, visit ►http://creativecommons.org/licenses/by-nd/2.5/ or send a letter to Creative Commons, 543 Howard Street, 5th Floor, San Francisco, California, 94105, USA. Contact the author to request other uses if necessary. Trademarks and service marks. All trademarks, service marks, logos and company names mentioned in this work are property of their respective owner. They are protected under trademark law and unfair competition law. The importance of the glossary. It is strongly recommended to read the glossary in full before starting with the first chapter. Hints for screen use. This work is optimized for both screen and paper use. It is recommended to use the digital version where applicable. It is a file in Portable Document Format (PDF) with hyperlinks for convenient navigation. All hyperlinks are marked with link flags (►). Hyperlinks in diagrams might be marked with colored borders instead. Navigation aid for bibliographic references. Bibliographic references to works which are publicly available as PDF files mention the logical page number and an offset (if non-zero) to calculate the physical page number.
    [Show full text]
  • Energy Efficiency State of the Art of Available Low-Gwprefrigerants And
    ENERGY EFFICIENCY STATE OF THE ART OF AVAILABLE LOW-GWP REFRIGERANTS AND SYSTEMS Final Report September 2018 Study commissioned by the AFCE and carried out by EReIE, the Cemafroid, and the CITEPA Authors : Stéphanie Barrault (CITEPA) Olivier Calmels (Cemafroid) Denis Clodic (EReIE) Thomas Michineau (Cemafroid) ACKNOWLEDGEMENTS We sincerely thank the members of the Steering Committee for their contributions: Bénédicte BALLOT-MIGUET, EDF Emmanuelle BRIERE, UNICLIMA Tristan HUBE, Service Entreprises et Dynamiques Industrielles, ADEME Laurent GUEGAN, François HEYNDRICKX, Régis LEPORTIER, François PIGNARD, AFCE. We would also like to thank all the professionals contacted as part of the study Copyright 2018 Any representation or reproduction in whole or in part without the consent of the authors or their heirs or successors is illegal according to the Code of Intellectual Property (Art. L 122-4) and constitutes an infringement punishable under the Criminal Code. Only are allowed (art. 122-5) copies or reproductions strictly reserved for private use and not intended for collective use, as well as analyzes and short quotations justified by the critical pedagogical character, or information the work to which they are incorporated, subject, however, to compliance with the provisions of Articles L122-10 to L122-12 of the Code, relating to reprographic reproduction. 2 / 131 Content CONTENT Content 3 List of Figures _________________________________________________________________ 6 List of Tables _________________________________________________________________
    [Show full text]
  • Hermetic Gas Fired Residential Heat Pump
    HERMETIC GAS FIRED RESIDENTIAL HEAT PUMP David M. Berchowitz, Director and Yong-Rak Kwon, Senior Engineer Global Cooling BV, Ijsselburcht 3, 6825 BS Arnhem, The Netherlands Tel: 31-(0)26-3653431, Fax: 31-(0)26-3653549, E-mail: [email protected] ABSTRACT The free-piston Stirling engine driven heat pump (FPSHP) is presented as an alternative residential heat pump technology. In this type of heat pump system the mechanical output of an externally heated free-piston Stirling engine (FPSE) is directly connected to a Rankine or transcritical cycle heat pump by way of a common piston assembly. The attractiveness of this system is the economics of operation when compared to an electrically driven conventional heat pump as well as the low environmental impact of the system. It is expected that the primary energy ratio for the ground water source FPSHP will be close to 2.15 for heating mode and 3.34 for cooling mode with the inclusion of domestic hot water generation. The working fluids are dominantly helium (He) gas for the engine and carbon dioxide (CO2) for the heat pump. Technical concerns for this system include the effects of working medium mixing and the load stability under various operating conditions. The direct connection of the Stirling engine to the compressor of the heat pump allows for the working fluids to mix with each other. He separation for the heat pump is discussed and the effect of the mixing of working fluids on both the heat pump and Stirling engine is investigated through a demonstrative experiment and simulation. Experimental verification of the performance due to the mixed working fluid is presented for the heat pump cycle, while simulation techniques with proper gas mixture properties are used to determine the effect on the Stirling cycle.
    [Show full text]
  • Fluid Selection of Transcritical Rankine Cycle for Engine Waste Heat Recovery Based on Temperature Match Method
    energies Article Fluid Selection of Transcritical Rankine Cycle for Engine Waste Heat Recovery Based on Temperature Match Method Zhijian Wang 1, Hua Tian 2, Lingfeng Shi 3, Gequn Shu 2, Xianghua Kong 1 and Ligeng Li 2,* 1 State Key Laboratory of Engine Reliability, Weichai Power Co., Ltd., Weifang 261001, China; [email protected] (Z.W.); [email protected] (X.K.) 2 State Key Laboratory of Engines, Tianjin University, Tianjin 300072, China; [email protected] (H.T.); [email protected] (G.S.) 3 Department of Thermal Science and Energy Engineering, University of Science and Technology of China, Hefei 230027, China; [email protected] * Correspondence: [email protected] Received: 6 March 2020; Accepted: 8 April 2020; Published: 10 April 2020 Abstract: Engines waste a major part of their fuel energy in the jacket water and exhaust gas. Transcritical Rankine cycles are a promising technology to recover the waste heat efficiently. The working fluid selection seems to be a key factor that determines the system performances. However, most of the studies are mainly devoted to compare their thermodynamic performances of various fluids and to decide what kind of properties the best-working fluid shows. In this work, an active working fluid selection instruction is proposed to deal with the temperature match between the bottoming system and cold source. The characters of ideal working fluids are summarized firstly when the temperature match method of a pinch analysis is combined. Various selected fluids are compared in thermodynamic and economic performances to verify the fluid selection instruction. It is found that when the ratio of the average specific heat in the heat transfer zone of exhaust gas to the average specific heat in the heat transfer zone of jacket water becomes higher, the irreversibility loss between the working fluid and cold source is improved.
    [Show full text]
  • Thermodynamic Comparison of Subcritical and Transcritical Heat Pump Water Heater (HPWH) Efficiency
    CO2 vs. Fluorocarbons: Thermodynamic Comparison of Subcritical and Transcritical Heat Pump Water Heater (HPWH) Efficiency Kyle R. Gluesenkamp Kashif Nawaz ACEEE Hot Water Forum Nashville, March 13, 2019 Session 4A ORNL is managed by UT-Battelle, LLC for the US Department of Energy Acknowledgments • Department of Energy (Contract DE-EE0006718.00) • Antonio Bouza, DOE Building Technology Office DISCLAIMER This material has been authored by UT-Battelle, LLC under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes. The Department of Energy will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan (http://energy.gov/downloads/doe-public-access-plan). 2 Classification of HPWHs Pumped (or external): Wrap-around: Immersed coil: HX Evaporator Evaporator Evaporator 3 Classification of Stratification Types (Stratification During Heating) Table 1. Tank Stratification Categories Heat exchanger (HX) Locations of tank High pressure used to transfer water taps, OR Stratifying Category refrigerant Water or refrigerant flow type refrigerant heat to coil vertical span potential glide water 1 Water pumped to HX Bottom and top Any Single pass (low
    [Show full text]
  • Comparison of ORC Turbine and Stirling Engine to Produce Electricity from Gasified Poultry Waste
    Sustainability 2014, 6, 5714-5729; doi:10.3390/su6095714 OPEN ACCESS sustainability ISSN 2071-1050 www.mdpi.com/journal/sustainability Article Comparison of ORC Turbine and Stirling Engine to Produce Electricity from Gasified Poultry Waste Franco Cotana 1,†, Antonio Messineo 2,†, Alessandro Petrozzi 1,†,*, Valentina Coccia 1, Gianluca Cavalaglio 1 and Andrea Aquino 1 1 CRB, Centro di Ricerca sulle Biomasse, Via Duranti sn, 06125 Perugia, Italy; E-Mails: [email protected] (F.C.); [email protected] (V.C.); [email protected] (G.C.); [email protected] (A.A.) 2 Università degli Studi di Enna “Kore” Cittadella Universitaria, 94100 Enna, Italy; E-Mail: [email protected] † These authors contributed equally to this work. * Author to whom correspondence should be addressed; E-Mail: [email protected]; Tel.: +39-075-585-3806; Fax: +39-075-515-3321. Received: 25 June 2014; in revised form: 5 August 2014 / Accepted: 12 August 2014 / Published: 28 August 2014 Abstract: The Biomass Research Centre, section of CIRIAF, has recently developed a biomass boiler (300 kW thermal powered), fed by the poultry manure collected in a nearby livestock. All the thermal requirements of the livestock will be covered by the heat produced by gas combustion in the gasifier boiler. Within the activities carried out by the research project ENERPOLL (Energy Valorization of Poultry Manure in a Thermal Power Plant), funded by the Italian Ministry of Agriculture and Forestry, this paper aims at studying an upgrade version of the existing thermal plant, investigating and analyzing the possible applications for electricity production recovering the exceeding thermal energy. A comparison of Organic Rankine Cycle turbines and Stirling engines, to produce electricity from gasified poultry waste, is proposed, evaluating technical and economic parameters, considering actual incentives on renewable produced electricity.