FA-M3 Temperature Control and Monitoring Modules and PID Control Module IM 34M6H61-01E 2Nd Edition
Total Page:16
File Type:pdf, Size:1020Kb
User’s Manual Temperature Control and Monitoring Modules and PID Control Module IM 34M6H61-01E IM 34M6H61-01E 2nd Edition Yokogawa Electric Corporation i Applicable Product: - Model Code : F3CT04-0N - Name : Temperature Control and Monitoring Module - Model Code : F3CT04-1N - Name : Temperature Control and Monitoring Module - Model Code : F3CR04-0N - Name : Temperature Control and Monitoring Module - Model Code : F3CR04-1N - Name : Temperature Control and Monitoring Module - Model Code : F3CV04-1N - Name : PID Control Module The document number and document model code for this manual are given below. Refer to the document number in all communications; also refer to the document number or the document model code when purchasing additional copies of this manual. - Document No. : IM 34M6H61-01E - Document Model Code : DOCIM Media No. IM 34M6H61-01E (FD) 2nd Edition : Aug, 2001 (CR) IM 34M6H61-01E 2nd Edition : Aug, 2001-00 All Rights Reserved, Copyright © 1999, Yokogawa Electric Corporation ii Important About This Manual - This Manual should be passed on to the end user. - Before using the controller, read this manual thoroughly to have a clear understanding of the controller. - This manual explains the functions of this product, but there is no guarantee that they will suit the particular purpose of the user. - Under absolutely no circumstances may the contents of this manual be transcribed or copied, in part or in whole, without permission. - The contents of this manual are subject to change without prior notice. - Every effort has been made to ensure accuracy in the preparation of this manual. However, should any errors or omissions come to the attention of the user, please contact the nearest Yokogawa Electric representative or sales office. Safety Precautions when Using/Maintaining the Product - The following safety symbols are used on the product as well as in this manual. Danger. This symbol on the product indicates that the operator must follow the instructions laid out in this instruction manual to avoid the risk of personnel injuries, fatalities, or damage to the instrument. The manual describes what special care the operator must exercise to prevent electrical shock or other dangers that may result in injury or the loss of life. Protective Ground Terminal. Before using the instrument, be sure to ground this terminal. Function Ground Terminal. Before using the instrument, be sure to ground this terminal. Alternating current. Indicates alternating current. Direct current. Indicates direct current. IM 34M6H61-01E 2nd Edition : Aug, 2001-00 iii The following symbols are used only in the instruction manual. WARNING Indicates a “Warning”. Draws attention to information essential to prevent hardware damage, software damage or system failure. CAUTION Indicates a “Caution” Draws attention to information essential to the understanding of operation and functions. TIP Indicates a “TIP” Gives information that complements the present topic. SEE ALSO Indicates a “SEE ALSO” reference. Identifies a source to which to refer. - For the protection and safe use of the product and the system controlled by it, be sure to follow the instructions and precautions on safety stated in this manual whenever handling the product. Take special note that if you handle the product in a manner other than prescribed in these instructions, the protection feature of the product may be damaged or impaired. In such cases, Yokogawa cannot guarantee the quality, performance, function and safety of the product. - When installing protection and/or safety circuits such as lightning protection devices and equipment for the product and control system as well as designing or installing separate protection and/or safety circuits for fool-proof design and fail-safe design of processes and lines using the product and the system controlled by it, the user should implement it using devices and equipment, additional to this product. - If component parts or consumable are to be replaced, be sure to use parts specified by the company. - This product is not designed or manufactured to be used in critical applications which directly affect or threaten human lives and safety — such as nuclear power equipment, devices using radioactivity, railway facilities, aviation equipment, air navigation facilities, aviation facilities or medical equipment. If so used, it is the user’s responsibility to include in the system additional equipment and devices that ensure personnel safety. - Do not attempt to modify the product. Exemption from Responsibility - Yokogawa Electric Corporation (hereinafter simply referred to as Yokogawa Electric) makes no warranties regarding the product except those stated in the WARRANTY that is provided separately. - Yokogawa Electric assumes no liability to any party for any loss or damage, direct or indirect, caused by the user or any unpredictable defect of the product. IM 34M6H61-01E 2nd Edition : Aug, 2001-00 iv Software Supplied by the Company - Yokogawa Electric makes no other warranties expressed or implied except as provided in its warranty clause for software supplied by the company. - Use the software with one computer only. You must purchase another copy of the software for use with each additional computer. - Copying the software for any purposes other than backup is strictly prohibited. - Store the original media, such as floppy disks, that contain the software in a safe place. - Reverse engineering, such as decompiling of the software, is strictly prohibited. - No portion of the software supplied by Yokogawa Electric may be transferred, exchanged, or sublet or leased for use by any third party without prior permission by Yokogawa Electric. IM 34M6H61-01E 2nd Edition : Aug, 2001-00 v General Requirements for Using the FA-M3 G Avoid installing the FA-M3 in the following locations: - Where the instrument will be exposed to direct sunlight, or where the operating temperature exceeds the range 0qC to 55qC (0qF to 131qF). - Where the relative humidity is outside the range 10 to 90%, or where sudden temperature changes may occur and cause condensation. - Where corrosive or flammable gases are present. - Where the instrument will be exposed to direct mechanical vibration or shock. - Where the instrument may be exposed to extreme levels of radioactivity. G Use the correct types of wire for external wiring: - Use copper wire with temperature ratings greater than 75qC. G Securely tighten screws: - Securely tighten module mounting screws and terminal screws to avoid problems such as faulty operation. - Tighten terminal block screws with the correct tightening torque as given in this manual. G Securely lock connecting cables: - Securely lock the connectors of cables, and check them thoroughly before turning on the power. G Interlock with emergency-stop circuitry using external relays: - Equipment incorporating the FA-M3 must be furnished with emergency-stop circuitry that uses external relays. This circuitry should be set up to interlock correctly with controller status (stop/run). G Ground for low impedance: - For safety reasons, connect the [FG] grounding terminal to a Japanese Industrial Standards (JIS) Class 3 Ground. For compliance to CE Marking, use cables such as twisted cables which can ensure low impedance even at high frequencies for grounding. G Configure and route cables with noise control considerations: - Perform installation and wiring that segregates system parts that may likely become noise sources and system parts that are susceptible to noise. Segregation can be achieved by measures such as segregating by distance, installing a filter or segregating the grounding system. G Configure for CE Marking Conformance: - For compliance with CE Marking, perform installation and cable routing according to the description on compliance to CE Marking in the “Hardware Manual” (IM34M6C11-01E). G Keep spare parts on hand: - Stock up on maintenance parts including spare modules, in advance. IM 34M6H61-01E 2nd Edition : Aug, 2001-00 vi G Discharge static electricity before operating the system: - Because static charge can accumulate in dry conditions, first touch grounded metal to discharge any static electricity before touching the system. G Never use solvents such as paint thinner for cleaning: - Gently clean the surfaces of the FA-M3 with a cloth that has been soaked in water or a neutral detergent and wringed. - Do not use volatile solvents such as benzine or paint thinner or chemicals for cleaning, as they may cause deformity, discoloration, or malfunctioning. G Avoid storing the FA-M3 in places with high temperature or humidity: - Since the CPU module has a built-in battery, avoid storage in places with high temperature or humidity. - Since the service life of the battery is drastically reduced by exposure to high temperatures, take special care (storage temperature should be from –20qC to 75qC). - There is a built-in lithium battery in a CPU module and temperature control module which serves as backup power supply for programs, device information and configuration information. The service life of this battery is more than 10 years in standby mode at room temperature. Take note that the service life of the battery may be shortened when installed or stored at locations of extreme low or high temperatures. Therefore, we recommend that modules with built-in batteries be stored at room temperature. G Always turn off the power before installing or removing modules: - Failing to turn off the power supply when installing or removing modules,