Msd600m++ & Pt0600m

Total Page:16

File Type:pdf, Size:1020Kb

Msd600m++ & Pt0600m DK MSD600M_4pp_Sep09:Layout 1 24/8/09 11:30 Page 1 PRODUCT CODE: MSD600M++ & PT0600M Features... • The Peak Programme Meter measures level of up to 32 audio channels simultaneously. • 7 scales directly selectable to conform to standard used. • PPM colours and headings are user programmable for easy identification. • Vectorscope for stereo and surround sound with unique JellyFish™ & StarFish™ display supports aural impression at a glance. • Multiple phase correlation meter indicates proper phasing to allow for downmix . • Rotary knob controls output volume for The MSD600M++ and PT0600M, Stereo SURROUND SOUND direct connection to active monitor and Surround Sound Meters, from DK- loudspeakers (PT0660) Technologies offer phasemeter, audio As surround sound becomes more and more the standard vector oscilloscope and PPM / VU level • 10 presets are directly accessible for fast in studios nowadays, accurate audio monitoring is recall of settings (PT0660) meter as the primary tools. becoming increasingly important. DK-Technologies‘ exclusive Jelly-Fish™ and StarFishTM surround • Modular, choice of input modules The Level Meter has direct selection of 7 PPM/VU scales. indicators have become the adopted standard, accepting analogue audio, AES3 and All the standard scales are available including Nordic, presenting the surround sound image in a logical and SDI, with de-embedder for SDI video. EBU, BBC, ABC, NBC, DIN, VU, Digital and others. Each intuitive way. The level and energy content of all channels scale can be configured individually concerning overload • Flexible, up to 8 analogue audio is easily recognizable on the screen. Signal correlation level and reference level. Furthermore the colour and outputs and 4 AES3 outputs connect via and phase errors in individual vectors are immediately width of each PPM bar can be set by the user. the internal matrix to any input, highlighted by different colours. internal audio generator, and sum and difference amplifiers. The DK-Scale™ software program for Windows contains a large library of scales which easily can be downloaded COMPACT & MODULAR • Choice of 1024-point FFT spectrum to the meter. Modification of existing scales or designing analyser and 1/3-octave analyser for new scales according to your own specifications are also The instruments are very compact units. Everything has display of frequency distribution of possible with the software. For easy identification each been fitted into a box not much bigger than the size of a each channel over full audible range. channel can individually be named with up to 4 pocketbook. The MSD600M++ will fit nicely into your • AES3 bitstream status display indicates characters. console or work desk, and the PT0600M sits conveniently characteristics of the digital audio next to a video waveform monitor. The unit can be user- signal. The oscilloscope shows the stereo image in the Lissajous- configured by deciding the number of input and output format, where a perfect stereo signal would be modules that easily fits into the rear of the unit. In total • Bright, VGA colour display with represented by a circular figure, or a ‘ball’, and mono it will hold 4 input modules and 4 output modules. adjustable backlight allows adaptation would be a vertical line. to environmental light conditions A parallel I/O module is available for remote control of • VGA output connects directly to an The phasemeter is of the “center-zero” type and softkeys and direct selection of presets or other interface external monitor for remote or larger immediately advises out-of-phase errors by pointing purposes and takes up one output slot, thus reducing the display. towards the [-1] area and changing to red colour. maximum output modules to 3. The I/O module controls up to 23 functions. The special utility module holds the power connection, the RS232 communication port, a sync input and the output for an external VGA-monitor. The Next Generation SOLUTIONS IN AUDIO & VIDEO DK MSD600M_4pp_Sep09:Layout 1 24/8/09 11:30 Page 2 The MSD600M++ SIGNAL GENERATOR & SPECTRUM ANALYSER CONFIGURATION meters feature... • 5.1/6.1/7.1 Surround A key feature of the A choice of different input modules is Sound Metering MSD600 is the built-in available for the Stereo and Surround signal generator. It has a Sound Meter. To accommodate these • DK-Technologies tone generator variable in modules the base unit has 4 input slots JellyFish™ frequency from 31 Hz to and 4 output slots each providing space • DK-Technologies 20000 Hz, and the level in for one module. StarFish™ Steps of 0,1 dB. The four input module slots are • ITU Loudness It can generate BLITS (Black & numbered In1 to In4 and modules must Lane’s Identification Tones be inserted sequentially in these slots. • 32 Analogue or digital for Surround) which provides MSD600M Display - BLITS tones. The first input module must be inserted audio Inputs channel identification tones for in slot In1, the next in slot In2 etc. The • 16 Analogue or digital all channels within a 5.1 Surround Sound signal. This also helps to provide information module priority, as listed in the table, audio Outputs in a stereo downmix - channel presence/absence. The BLITS tones can be used at the must be taken into account by assigning start of a programme to help identify channels, in OB trucks for channel identification modules sequentially to the input slot • 32x16 Audio Matrix back to the studio and MCR as well as line-up for storage devices. numbers with the highest priority module to the lowest slot number. • SDI Audio De-embedding It can also generate the EBU test signal, pulse signals, and white and pink noise signals • BLITS 5.1 Surround for use with the spectrum analysers. Use the generator to turn the instruments into The four output module slots are Sound Channel a powerful measurement tools for analysis of linearity and distortion. numbered O1 to O4 and modules must Identification be inserted sequentially in these slots. The spectrum analyser section has both an FFT-analyser and a 1/3 octave analyser. The The first output module must be inserted • Built-in Signal Generator FFT is primarily used for accurate measurements and exact identification of problem in slot O1, the next in slot O2 etc. for line up tones frequencies. To this end a cursor is available and level and frequency will be shown for each cursor position across the frequency range on the display. • Multiple meter scale INPUT SLOTS The 1/3-octave analyser has 30 bars, grouped in full octaves from 20 Hz to 16000 Hz. PRIORITY Input-1 This standard tool is primarily used during recording to check the energy distribution INPUT MODULES Input-2 Input-3 Input-4 Input-4 D/O A ++++ of the signal. 4 x AESS Input Module Input-8 A/O A ++++ BLITS Identification Tones 8 Analogue Input Module ++++ L 880Hz 1 KHz 1 KHz 2 KHz Input-SDI/4 B 4 ch. SD-SDI De-embedder max 2 x input modules R 880Hz 1 KHz 2 KHz Input-2D/O B ++++ The FFT spectrum of the input signal is calculated C 1,320Hz 2 KHz 2 x AESS Input Module at 1024 discrete frequencies. LFE 82.5Hz 2 KHz Input/1 C ++++ 1 x AESS + 2 x Analogue Input Ls 660Hz 2 KHz Input/2 C ++++ 1 x AESS + 2 x Analogue Input Rs 660Hz 2 KHz Modules with higher priority must be placed in an input slot with a lower number starting with the In-1 slot. 4.8 Sec 5.3 Sec 3.3 Sec BLITS Tone Sequence. OUTPUT SLOTS MODULAR CONSTRUCTION OUTPUT MODULES PRIORITY Output-1 The 1/3-Octave spectrum shows the energy Output-2 Output-3 Output-4 distribution of the input signal. Output/1 A ++++ 1 x AESS + 2 x Analogue Output The Utility Module containing the power Output/2 A ++++ inlet, AES3 sync input, RS-232 1 x AESS + 2 x Analogue Output I/O-23 B + communication port, and the VGA Remote Control Module monitor output is standard built into the base unit. With a large variety of input and output modules optionally OTHER FUNCTIONS available, the audio meter can be The bit status display supplies information about the content and the physical layer of the AES3 configured to meet most requirements. In the digital mode the instruments will data signal. show a Bitstream Status Display. Other Even a later hardware upgrade to features are the time code input which A compact, rugged metal casing houses changed requirements are easily will synchronize to SMPTE, and a Solutions in the all-in-one audio metering unit. Easy accomplished by simply plugging new Statistical Session Report showing Audio & Video access to the input/output modules are modules into the rear and fasten it with highest true peak, number of clippings, obtained from the rear side. 2 screws. and number of mutes over time. DK MSD600M_4pp_Sep09:Layout 1 24/8/09 11:30 Page 3 PRODUCT CODE: MSD600M++, Desktop PT0600M, Rack Mount AUDIO MATRIX MSD600M++ & PT0600M - HARDWARE SPECIFICATIONS PPM Analogue References MSD600M-Input/1 • Indication: 0 dBu Analogue & AES3 Input Module • Input voltage: 1.55 V Input module with 2 analogue audio inputs and 1 AES3 input. PPM Scales • Input connector: 15-pole D-Sub Dynamic response: • 2 x 75ΩBNC (Input/2 only) • Pflichtenheft 3/6: 3 ms / -3 dB • IEC 268-10: 5 ms / -2 dB Analogue inputs • IEC 268-17: VU: 300 ms • Maximum input level: +24 dBu Return (fallback) time: • Sample rate with internal sync: 48 kHz • Pflichtenheft 3/6: 20 dB / 1.5 s • Sample rate range with external sync: 32 • IEC 268-10: 20 dB / 20 s kHz to 50 kHz Division of scales: • Bit resolution: 24 bits • Type I: -42 dB to +12 dB • Frequency range within ±0.3 dB: 30 Hz to • Type IIA: 1 to 7 (-12 dB to +12 dB) 20 kHz • Type IIB: -12 dB to +12 dB • Passband ripple: ±0,002 dB • Type DIN: -50 to +5 dB • Group delay: less than 0.82 msec • Type VU: -20 dB to +3 dB • Dynamic range, A-weighted: more than The instruments contain a complete 32 x 16 audio matrix.
Recommended publications
  • CCIF (Geneva, 1954)
    This electronic version (PDF) was scanned by the International Telecommunication Union (ITU) Library & Archives Service from an original paper document in the ITU Library & Archives collections. La présente version électronique (PDF) a été numérisée par le Service de la bibliothèque et des archives de l'Union internationale des télécommunications (UIT) à partir d'un document papier original des collections de ce service. Esta versión electrónica (PDF) ha sido escaneada por el Servicio de Biblioteca y Archivos de la Unión Internacional de Telecomunicaciones (UIT) a partir de un documento impreso original de las colecciones del Servicio de Biblioteca y Archivos de la UIT. (ITU) ﻟﻼﺗﺼﺎﻻﺕ ﺍﻟﺪﻭﻟﻲ ﺍﻻﺗﺤﺎﺩ ﻓﻲ ﻭﺍﻟﻤﺤﻔﻮﻇﺎﺕ ﺍﻟﻤﻜﺘﺒﺔ ﻗﺴﻢ ﺃﺟﺮﺍﻩ ﺍﻟﻀﻮﺋﻲ ﺑﺎﻟﻤﺴﺢ ﺗﺼﻮﻳﺮ ﻧﺘﺎﺝ (PDF) ﺍﻹﻟﻜﺘﺮﻭﻧﻴﺔ ﺍﻟﻨﺴﺨﺔ ﻫﺬﻩ .ﻭﺍﻟﻤﺤﻔﻮﻇﺎﺕ ﺍﻟﻤﻜﺘﺒﺔ ﻗﺴﻢ ﻓﻲ ﺍﻟﻤﺘﻮﻓﺮﺓ ﺍﻟﻮﺛﺎﺋﻖ ﺿﻤﻦ ﺃﺻﻠﻴﺔ ﻭﺭﻗﻴﺔ ﻭﺛﻴﻘﺔ ﻣﻦ ﻧﻘﻼ ً◌ 此电子版(PDF版本)由国际电信联盟(ITU)图书馆和档案室利用存于该处的纸质文件扫描提供。 Настоящий электронный вариант (PDF) был подготовлен в библиотечно-архивной службе Международного союза электросвязи путем сканирования исходного документа в бумажной форме из библиотечно-архивной службы МСЭ. © International Telecommunication Union INTERNATIONAL TELEPHONE CONSULTATIVE COMMITTEE (C. C. I. F.) XVIIth PLENARY ASSEMBLY GENEVA, 4-12 OCTOBER, 1954 VOLUME III LINE TRANSMISSION MAINTENANCE Published by the International Telecommunication Union Geneva, 1956 INTERNATIONAL TELEPHONE CONSULTATIVE COMMITTEE (C. C. I. F.) XVIIth PLENARY ASSEMBLY GENEVA, 4-12 OCTOBER, 1954 VOLUME III LINE TRANSMISSION MAINTENANCE PAGE INTENTIONALLY LEFT BLANK PAGE LAISSEE EN BLANC INTENTIONNELLEMENT TABLE OF CONTENTS OF VOLUME III OF THE GREEN BOOK OF THE C.C.I.F. Line Transmission Maintenance Page Tables summarising the characteristics of circuits: Telephony (and telegraphy)................................................................................................... 16 Programme transm issions.......................................................................................... 18 T elevision.........................................
    [Show full text]
  • ABBREVIATIONS EBU Technical Review
    ABBREVIATIONS EBU Technical Review AbbreviationsLast updated: January 2012 720i 720 lines, interlaced scan ACATS Advisory Committee on Advanced Television 720p/50 High-definition progressively-scanned TV format Systems (USA) of 1280 x 720 pixels at 50 frames per second ACELP (MPEG-4) A Code-Excited Linear Prediction 1080i/25 High-definition interlaced TV format of ACK ACKnowledgement 1920 x 1080 pixels at 25 frames per second, i.e. ACLR Adjacent Channel Leakage Ratio 50 fields (half frames) every second ACM Adaptive Coding and Modulation 1080p/25 High-definition progressively-scanned TV format ACS Adjacent Channel Selectivity of 1920 x 1080 pixels at 25 frames per second ACT Association of Commercial Television in 1080p/50 High-definition progressively-scanned TV format Europe of 1920 x 1080 pixels at 50 frames per second http://www.acte.be 1080p/60 High-definition progressively-scanned TV format ACTS Advanced Communications Technologies and of 1920 x 1080 pixels at 60 frames per second Services AD Analogue-to-Digital AD Anno Domini (after the birth of Jesus of Nazareth) 21CN BT’s 21st Century Network AD Approved Document 2k COFDM transmission mode with around 2000 AD Audio Description carriers ADC Analogue-to-Digital Converter 3DTV 3-Dimension Television ADIP ADress In Pre-groove 3G 3rd Generation mobile communications ADM (ATM) Add/Drop Multiplexer 4G 4th Generation mobile communications ADPCM Adaptive Differential Pulse Code Modulation 3GPP 3rd Generation Partnership Project ADR Automatic Dialogue Replacement 3GPP2 3rd Generation Partnership
    [Show full text]
  • Studio-Sound-1976-09
    www.americanradiohistory.com We know it helps the manufacturer to set rigid standardisation of their equipment formats - most do! It doesn't help you. The penalty need not be a sharp increase in cost We at Cadac do not expect you to suffer these short comings. Our fully modularised range of equipment leaves the flexibility of choice with you - and the cost? Lower than you would expect on a console for console comparison basis. The most versatile recording equipment in the world. S ti {'4 4 asaa+ndaliAarlf Z b 4\ a a a '` ' " {ti yE 4à4 47 ÿ4'4 ,t : :ttttp1Ñ.;v'Y+°rti , ?AA _.. t' S, A.Vfifii"4446*0é : 04 r . VOGUE P.I.P STUDIOS - FRANCE The leaders in music recording consoles and techniques. Cadac (London) Ltd. 141, Lower Luton Road Harpenden Herts. AL5 5EL 3 Harpenden (STD 05827) 643511 Telex 826323 www.americanradiohistory.com i' ITOR RAY CARTER TECHNICAL EDITOR FRANK OGDEN EDITORIAL PRODUCTION studio sound DRUSILLA DALRYMPLE :ONSULTANT HUGH FORD AND BROADCAST ENGINEERING ECUTIVE ADVERTISEMENT ANAGER For nearly ten years Dolby A has effectively been the industry standard for noise reduction; DOUGLAS G. SHUARD other systems, despite their merits, amounted to opposition rather than competition. However, ADVERTISEMENT MANAGER more tracks and greater use of ping -pong within the rest of the recording chain now TONY NEWMAN pressurises studios into overriding the wishes of their accountants by obtaining a double kDVERTISEMENT REPRESENTATIVE inventory of noise reduction equipment. And of course the force for change is aided, as always, PHYLLIS BIRCH by the persistent technological rhetoric of those who have something to sell to those who haven't yet bought their quota; but that's life.
    [Show full text]
  • Pinguin Audio Meter Mac
    1 / 4 Pinguin Audio Meter Mac Subscribe now to Friedemann's Sound Kitchen: goo.gl/isy0AZDas neue ... stellt Pinguin PG-AMM .... Jul 2, 2009 — Pinguin Audio Meter PG-AM 4.5 · Stand-allone PC software with USB dongle. · Independent operation requires sound card with S/P- DIF or AES/ .... Pinguin Audio Meter Mac >>> http://bytlly.com/18ejhv. ... Free,pinguin,audiometer,downloads,.,Pinguin,Audio,Meter,has,4,build,in,high,quality,16bit,instruments .... May 15, 2008 — (Plus it runs well under Parallels on my MacBook Pro ;-); Pinguin Audio Meter Not free but comes in several flavours, the Pro version includes .... Sep 11, 2010 — The PINGUIN Audio Multi Meter, PG-AMM for short, can be seen in use ... All the meters run native on standard PCs (with Windows® or Mac OS .... Oct 24, 2019 — Since 1988 the german engineering service Pinguin cares about ways to enhance professional digital audio with easy user interfacing.. Coleman Audio MBP2 Stereo Desktop VU Meter for Balanced XLR Audio The MBP2 ... Support Communities / Desktop Computers / Mac mini Looks like no one's ... Multimedia tools downloads - Pinguin Audio Meter by Pinguin HH Germany .... Pinguin Audio – Meter Standard 2.3 Build 600 WiN KGN AiR/BEAT | 2009 | Use Compatibility ... pinguin audio meter 4.5 torrent ... guitar pro crashes on mac. Pinguin Audio Meter Free Decibel Meter Pinguin Audio Meter Torrent Azureus And Pinguin... powered by Peatix : More than a ticket.. Pinguin PG-AMM stereo multi-meter for MAC and PC with USB dongle, max. 10 instruments ... Pinguin. Audio Meter 2.3.0.600 + Crack Keygen/Serial.. Pinguin Audio Multi Meter (PG-AMM) is a very powerful and accurate digital Audio- Metering-System for stereo.
    [Show full text]
  • TI S4 Audio Frequency Test Apparatus.Pdf
    TECHNICAL INSTRUCTION S.4 Audio-frequency Test Apparatus BRITISH BROADCASTING , CORPORATION ENGINEERING DlVlSlON - ', : . iv- TECHNICAL INSTRUCTION S.4 Third Issue 1966 instruction S.4 Page reissued May. 1966 CONTENTS Page Section I . Amplifier Detector AD14 . 1.1 Section 2 . Variable Attenuator AT119 . Section 3 . Wheatstone Bridge BG/I . Section 4 . Calibration IJnit CALI1 . Section 5. Harmonic Routine Tester FHP/3 . Section 6 . 0.B. Testing Unit 0BT/2 . Section . 7 . Fixed-frequency Oscillators OS/9. OS/ 10. OS/ IOA . Section 8 . Variable-frequency Oscillators TS/5 .. TS/7 . 1' . TS/8 . TS/9 . TS/ 10. TS/ 1OP . Section 9 . Portable Oscillators PTS/9 . PTS/IO . ... PTS/12 . PTS/13 . PTS/l5 .... PTS/l6 .... Appendix . The Zero Phase-shift Oscillator with Wien-bridge Control Section 10. Transmission Measuring Set TM/I . Section 1 I . Peak Programme Meter Amplifiers PPM/2 ..... PPM/6 . TPM/3 . Section 12 Valve Test Panels VT/4. VT/5 "d . Section 13. Microphone Cable Tester MCT/I . Section 14 . Aural Sensitivity Networks ASN/3. ASN/4 Section 15 . Portable Amplifier Detector PAD19 . Section 16. Portable Intermodulation Tester PIT11 Section 17. A.C. Test Meters ATM/I. ATM/IP . Section 18 . Routine Line Testers RLT/I. RLT/IP . Section 19. Standard Level Panel SLP/3 . Section 20 . A.C. Test Bay AC/55 . Section 21 . Fixed-frequency Oscillators: OS2 Series Standard Level Meter ME1611 . INSTRUCTION S.4 Page reissued May 1966 ... CIRCUIT DIAGRAMS AT END Fig. 1. Amplifier Detector AD14 Fig. 2. Wheatstone Bridge BG/1 Fig. 3. Harmonic Routine Tester FHP/3 Fig. 4. Oscillator OS/9 Fig.
    [Show full text]
  • Peak Programme Meters
    Peak Programme Meters Audio signals in nature can cover an extremely wide dynamic range extending from, at the quietest level, below the threshold of hearing to, at the loudest level, greatly in excess of the threshold of pain! Broadcasters of course do not attempt to emulate this dynamic range, and for entirely practical reasons a very much reduced dynamic level variation must be transmitted. The Listener, or Viewer, will adjust the volume setting in their own home environment so that the Programme is clearly audible above the domestic background noise which will vary from location to location. Invariably Broadcasters restrict the dynamic level range of the transmitted Programme in order to increase the "impact" of the programme audio over this domestic ambience. The dynamic range is restricted by a combination of close- microphone and electronic compression using "dynamic limiters", and in essence, these techniques make the programme's audio sound louder than it would otherwise be. This compression is usually gross on Pop Music channels where the dynamic range is severely limited and often pretty obvious on Commercials too. Measuring audio levels, in a programme production environment, is more complicated than appears at first glance. Programme Audio is subject to the following:- 1) Wide, though restricted, dynamic range. 2) Wide, though restricted, frequency response. 3) Short duration transients 4) Positive and negative signal excursions are often different by many dB. 5) The degree of audio compression will affect measurements. 6) Stereo Phase considerations. 7) The metering must be clear and unambigous. 8).....and other more subtle effects. The characteristics of the measuring device itself totally weight the achieved measurement.
    [Show full text]
  • R&D Report 1963-29
    ~ I' I RESEARCH DEPARTMENT THE RELATIVE MERITS OF THE V,U. METER AND PEAK PROGRAMME METER IN THE REGULATION OFAoFo SIGNALS IN BROADCASTING Report No, L-OS4 (1963/29 ) ;.,y9.,c lwn-.J.;\/.st:Jlt1'L ._ - . E. R, Wigan, Eo Se. (Eng), A.M. LE. E- (W. Proctor Wilson) This Report 1. the property of the British Broadcasting Corporation and may not be reproduced in any form wlthout the written permission of the Corporation. Report No. L-054 THE RELATIVE MERITS OF THE V.U. METER AND PEAK PROGRAMME METER IN THE REGULATION OF A. F. SIGNALS IN BROADCASTING Section Title Page SUMMARY 1 L INTRODUCTION 1 THE MAINTENANCE OF HIGH AVERAGE MODULATION DEPTH 2 3,. THE REGULATION OF THE MAXIMA AND MINIMA OF THE PROGRAMME SIGNAL RANGE 0 • • • • • • • • • • • • • • • • • • 2 4. OBSERVATIONS ON THE PERFORMANCE OF THE V.U. METER AS A PEAK- INDICATING INSTRUMENT . 0 • • • • • • • • • • • • 3 5. THE USE OF PROGRAMME METERS FOR TRANSMISSION MEASUREMENT 4 6. V.U. METERS AND PEAK-READING INSTRUMENTS USED AS LOUDNESS METERS ....................... 5 CONCLUSIONS 5 REFERENCES 6 Report No. L-OS4 August 1963 (1963/29) THE RELATIVE MERITS OF THE VoU. METER AND PEAK PROGRAMME METER IN THE REGULATION OFAoFo SIGNALS IN BROADCASTING An arttcle published in the KB,U, Review No, 79-A, June 1963 SUMMARY TI1e relative merits of the 'VoU, meter' and 'Peak Programme Meter' (PoP~t) as volume~indicating devices have been hotly if inconclusively contested for many years, this article introduces some points which merit fuller discussion and is based on the experience gained by the BBC in the last decade, TIle conclusion is confirmed that a quasi-peak reading instrument such as the P .
    [Show full text]
  • Audio Metering
    Audio Metering Measurements, Standards and Practice This page intentionally left blank Audio Metering Measurements, Standards and Practice Eddy B. Brixen AMSTERDAM l BOSTON l HEIDELBERG l LONDON l NEW YORK l OXFORD PARIS l SAN DIEGO l SAN FRANCISCO l SINGAPORE l SYDNEY l TOKYO Focal Press is an Imprint of Elsevier Focal Press is an imprint of Elsevier The Boulevard, Langford Lane, Kidlington, Oxford, OX5 1GB, UK 30 Corporate Drive, Suite 400, Burlington, MA 01803, USA First published 2011 Copyright Ó 2011 Eddy B. Brixen. Published by Elsevier Inc. All Rights Reserved. The right of Eddy B. Brixen to be identified as the author of this work has been asserted in accordance with the Copyright, Designs and Patents Act 1988 No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or any information storage and retrieval system, without permission in writing from the publisher. Details on how to seek permission, further information about the Publisher’s permissions policies and our arrangement with organizations such as the Copyright Clearance Center and the Copyright Licensing Agency, can be found at our website: www.elsevier.com/permissions This book and the individual contributions contained in it are protected under copyright by the Publisher (other than as may be noted herein). Notices Knowledge and best practice in this field are constantly changing. As new research and experience broaden our understanding, changes in research methods, professional practices, or medical treatment may become necessary. Practitioners and researchers must always rely on their own experience and knowledge in evaluating and using any information, methods, compounds, or experiments described herein.
    [Show full text]
  • Electronic-Engineeri
    ec ronic ngincerin JUNE 1951 3 WAY MIXER Fi• PEAK PROGRAMME METER for recording and large sound installations, etc. One milliwatt output on 600 ohm line (.775 V) for an input of 30 microvolts on 7.5-30 ohm balanced input. Output balanced or unbalanced by internal switch. The meter reading is obtained by a valve voltmeter with 1second time constant, which reads programme level, and responds to transient peaks. Calibration in 2 db steps, to plus 12 db and minus 20 db referred to zero level. Special low field internal power packs supplies 8 valves including stabilising and selenium rectifier, consumption 23 watts. Manufactured by VORTEXION LIMITED 257-263 THE BROADWAY, WIMBLEDON, LONDON, S.W.I9 Telephones: LIBerty 2814 and 6242-3. Telegrams: "Vortexion, Wimble, London ". The VITAL LINK For the to job of connecting the T/V Camera to the trol van something extra in the way of a tra g cable system is needed. This is well provi for in BICC T/V Camera Cables with mould -on Polypole Couplers. Take the 22-core cable for instance :by the use of single wire conductors the diameter is reducej to only •850 in.—two-thirds the size of its conve onal stranded wire equivalent! And the Polypo 1 Coupler, integrally moulded to the cable end, reduces he possibility of conductor breakage to a minimu Truly aperfect combination built for the job— dit bears the BICC hallmark of dependability. Our technical staff will be pleased to discus this new development with you. TIII CAMERA CABLE COUPLE BRITISH INSULATED CALLENDER'S CABLES LIMITED NORFOLK HOUSE, NORFOLK STREET, LONDON, W C.
    [Show full text]
  • The Ebu Standard Peak-Programme Meter for the Control of International Transmissions
    THE EBU STANDARD PEAK-PROGRAMME METER FOR THE CONTROL OF INTERNATIONAL TRANSMISSIONS Tech. 3205-E 2nd edition, November 1979 Note: This Technical Document is now superseded by EBU R128, “Loudness normalisation and permitted maximum level of audio signals”. The current document is therefore kept only as a historical record. CONTENTS Introduction............................................................................................................ 3 General.................................................................................................................. 5 TEXT Characteristics of the standard instrument ............................................................ 7 1. Presentation....................................................................................................... 7 2. Static performance............................................................................................. 8 3. Dynamic response........................................................................................... 10 4. Miscellaneous characteristics.......................................................................... 12 Appendix 1: Additional information for mechanical (galvanometer) instruments . 13 Appendix 2: Comparison of indications produced by other instruments.............. 15 LEGACY 2 Peak Programme Meter EBU Tech. 3205-E INTRODUCTION From the earliest days of broadcasting there has been a need for an instrument capable of measuring the amplitude of the electrical signals corresponding to a sound programme. This
    [Show full text]
  • Reports the Peak Program Meter and the Vu Meter In
    TQRIOI- THE PEAK PROGRAM METER AND THE VU METER TECH QC 1/11 IN BROADCASTING REPORTS OCT79 Organization of Content Introduction Advantages of the PPM Alleged Disadvantages of the PPM Characteristics of VU Meter, PPM, FCC Modulation Monitor and Chart Recordings The Meters and Program Level Meter Calibration and Deflections The PPM and Some Implications Conclusion Acknowledgments Introduction In September 79, ABC put into operation its new New York studio. Throughout its control rooms some 40 PPMs are employed (Fig. 1). All new ABC installations (e.g. the new Washington News Bureau) will be equipped with PPMs. At the SMPTE Toronto Section Meeting in February 78, the Canadian Broadcasting Corp. (CBC) reported that the CBC Vancouver plant employs 30 to 40 PPMs; only 1 to 2 VU meters are kept to settle Telco disputes (Fig. 2). Clearly, the Peak Program Meter is here to stay! In this report, I wish to sum up the present "Peak Program Meter situation" and discuss some practical operational problems that exist when VU meters and Peak Program Meters (PPMs) are used together in a broadcast plant. Anyone wishing to know more details of our investigations may refer to my papers in the IEEE Transactions on Broadcasting of MAR 77, the BME magazines of JUN and SEP 77 and the SMPTE Journal of JAN 76. The oral presentation of this report has a slightly different format. This is mainly because a TV monitor (from a video cassette) displays both meters side by side showing the meter deflections of the audio signal that one hears. TQR 101/3 Characteristics of VU meter, PPM, FCC Modulation Monitor and Chart recordings The VU Meter The VU Meter (per IEEE Std.
    [Show full text]
  • LA100 Audio Analyser Manual
    LA100 Audio Analyser Manual Sixth edition, June 2007 © 2007 Lindos Electronics Part number: MN100 This manual describes LA100 software version V6.7. Please refer to any accompanying update sheets if your LA100 displays a version number later than this when it is turned on or reset. Users familiar with earlier software should refer to appendix I.3 for a list of new features. We are continuously developing and enhancing the software within the LA100 and send major new software EPROMs to all users. You should therefore ensure that you complete and return the enclosed registration card directly to Lindos Electronics and advise of any change of ownership or change of address so that you receive these updates. All comments and suggestions regarding the LA100 will be gratefully received. LINDOS ELECTRONICS Technical Support (usually 24 hours): Saddlemakers Lane Telephone: +44 (1394) 380307 Melton WOODBRIDGE Fax: +44 (1394) 385156 Suffolk IP12 1PP email: [email protected] ENGLAND Contents 1.0 Introduction 9 1.1 Viewing Angle 9 1.2 Switching-On 9 1.3 The Keyboard 10 1.4 Reset 10 1.5 Memory Clear and Non-Volatile Memory 11 1.6 The Configuration Menu 12 1.7 Connectors 12 1.8 Technical Support 14 2.0 Manual Operation 15 2.1 Volume Control 15 2.2 Generating Tones 15 2.3 Measuring Tones 16 2.4 Channel Switching 18 2.5 Programmable Presets and Initial Settings 18 2.6 Relative Levels − Test Level (TL) 18 2.7 Measurement Options 19 2.8 Frequency Measurement 21 2.9 Phase Measurement 21 2.10 Noise Measurement 22 2.11 Rumble Measurement 23 2.12 Crosstalk
    [Show full text]