Overview of LEGION™ REVISION Knee Surgical Technique – Femur1 (with Offset option)

Ream the canal until cortical contact is Remove offset achieved using progressively larger and reamer. Attach reamers. Note stem length for depth value. femoral collet and ream 1 6 using counterbore reamer assembly. (Note: Set counterbore bushing on femur.)

7 2

Assess femoral A-P size, location of joint line and stem offset position.

Remove A-P block. Place the 120mm trial stem and trial stem connection rod in the canal. Ream using counterbore reamer assembly. (Note: Set counterbore bushing on femur.) Slide valgus guide 3 assembly over the reamer and lock in Assemble femoral trial and adjust the 8 position. Resect the offset coupler (if used) to predetermined distal femur. Make position. Insert the trial assembly into distal wedge cuts the femoral canal. if desired.

9 Select appropriate 12 size A-P femoral 11 o’clock cutting block and offset collet (2, 4 or 6mm) to get 4 optimal coverage. Note the clock position. Use pins 9 3 to hold the cutting block in position. (Note: tibial spacer blocks are available in set) 6 Select appropriate sized femoral trial cam module and insert into femoral trial box. Make AP and chamfer cuts. (Note: Use distal 10 shims to correctly position block. If used, posterior 5 chamfer cut is not required.)

Attach housing resection collet and prepare housing box using reamer and box .

1 Refer to LEGION Revision Knee System surgical technique brochure for additional information Overview of LEGION™ REVISION Knee Surgical Technique – Tibia1 (with Offset option)

Ream the canal until cortical Remove bushing and reamer. Ream contact is achieved using 5 using counterbore reamer assembly. progressively larger Reamers. (Note: Set counterbore bushing Note stem length for depth value. on tibia.) 1

6 Remove tibial counterbore bushing assembly. Place the 120mm Slide the tibial trial stem and trial 2 stem connection IM instrument 7 assembly on rod in the canal. to the reamer and lock. Resect tibia. Leave the reamer in the tibial canal.

Ream using counterbore reamer assembly. (Note: Set counterbore 3 bushing on tibia.)

Assemble trial Choose appropriate size tibial and adjust the guide and check if offset 8 offset coupler to is needed. predetermined position. Insert trial assembly into tibial canal.

Select appropriate offset (2,4 or 6mm) AND pin the drill guide. Note the location of the arrow mark. 4 9

Punch fin slots. If needed, resect for tibial wedges.

1 Refer to LEGION Revision Knee System surgical technique brochure for additional information ™Trademark of Smith & Nephew. US Pat. & TM Off. ©2005 Smith & Nephew, Inc. All rights reserved. 7128-1508 40420118 1/09