Tender Document
Total Page:16
File Type:pdf, Size:1020Kb
TERMS AND CONDITIONS The firm must be GST & NTN registered in case of exemption, proof should accompany the 1 quotation. 2 Minimum validation period of bids will be 90 days. Warranty condition should be distinctively and elaborately mentioned in the quotation for each 3 item. Quotations are to be submitted up to October 28, 2013 at 1:00 PM and tender will be opened at 4 02:00 PM on the same day. Payments will be made through cross cheque after deduction of all type of taxes as per prevailing 5 rates. After receipt satisfactory report of the Inspection Committee and acceptance of the items as per given specification. Rates must be inclusive of all taxes to be payable by supplier which will be deducted at the time 6 of final payment. The chairman purchase committee reserved the rights to accept or reject any part of the entire 7 tendered without assigning any reason. Earnest Money (refundable) at least @ 2% of the full value of items must be attached with the 8 bid in shape of CDR/Demand Draft/Pay Order/Banker’s Cheque in the name of DISTRICT MANAGER TEVTA RAWALPINDI. Copy of Sales Tax / Income Tax registration must be attached with request, on company 9 letterhead, for issuance of Tender. 10 Tender would be rejected if the amount of CDR is less than 2% of the quoted price. 10% security would be deducted from the bill at the time of payment and the same will be 11 released after warranty period. Tenders must be submitted separately for each technology along with earnest money/call deposit 12 Receipt or otherwise tender will be rejected. 13 Brochure of the item to be quoted must be attached. 14 Black listed firms will not be entertained. 15 In case of any query or information contact on telephone No: 051-9290347-48 Page 1 COMPARATIVE STATEMENT GCT TAXILA ELECTRICAL TECHNOLOGY BASIC LAB.NO.1 WIRING LAB Sr Unit Total Cost Total Cost ITEMS Specification Qty GST Remarks # Rate without with GST 3. Wire Guage Standard UK/ USA/ Japan/ 10 (imported) 0-45 SWG 01 Taiwan/ or No Equivalent 4. Micrometer Digital 0-25 UK/ USA/ Japan/ 10 mm (Inter/.Ext.) Taiwan/ or Equivalent 5. Knife Electrician Folding UK/ USA/ Japan/ 10 Type 4” Blade Taiwan/ or Equivalent Total Lab No.1 BASIC LAB.NO.2 8. Kelvin’s Double Bridge UK/ USA/ Japan/ 2 Portable: Taiwan/ or - Range 0.1 to 110 Ohm Equivalent - Built-in Galvanometer with protection 11. Phase Angle Meter UK/ USA/ Japan/ 1 Portable. Taiwan/ or - Display 3 digits with Equivalent polarity + (Lead) and – (Lag) - Voltage Range 10-400 V - Current Range 0.5 – 20 A 14. Potential Transformer: UK/ USA/ Japan/ 5 Primary Rating Taiwan/ or 220/440/2200/3300 V Equivalent Secondary Rlating 110 V 17. Lux Meter Digital: UK/ USA/ Japan/ 5 Range: 0-20000 lux Taiwan/ or Max/Data hold function Equivalent Backlit LCD display 22 Power Supply AC/DC UK/ USA/ Japan/ 1 Digital: Taiwan/ or Output AC Range: 0 to Equivalent 220V, 500mA Output DC Range: 0 to 220V, 10mA Input Voltage: 220/380V AC With protection. 31. Reheostat Air Core UK/ USA/ Japan/ 5 Resistance: Taiwan/ or -100W 2.503A Equivalent -200W 2.5-3 A -32W 2.5-3 A 34 Potentiomete/Resistance UK/ USA/ Japan/ 10 Substitution Box: Taiwan/ or Equivalent Page 2 Sr Unit Total Cost Total Cost ITEMS Specification Qty GST Remarks # Rate without with GST Low Range: 15 to 10,000 Equivalent Ohms High Range9:17 PM 15,000 to 10,000,000ohms Two 12-Step rotary switches allow selection of 24 values 37 Test and Fault detector UK/ USA/ Japan/ 2 Taiwan/ or Equivalent 38 Bench Growler UK/ USA/ Japan/ 4 Taiwan/ or Equivalent 40 AC Voltage Transducer: UK/ USA/ Japan/ 6 Taiwan/ or Input Voltage9:23 PM Equivalent 100V, 100/√3V, 110V, 110√3V, 230V, 400V Accuracy class: 0.2% Output: 0-5, 0-20mA,0-5, 0-10V 41 AC Current Transducer UK/ USA/ Japan/ 6 Input Current: 5A or 1A Taiwan/ or Accuracy class: 0.2% Equivalent Rated Frequency: 50 or 60 Hz Burden : <0.5VA Output: 0-5, 0-20mA, 0-5, 0-10V 42 Power Transducer Single UK/ USA/ Japan/ 6 Phase Taiwan/ or Equivalent 43 Power Line Transducer 3- UK/ USA/ Japan/ 6 Phase Taiwan/ or Equivalent 44 Frequency Transducer: UK/ USA/ Japan/ 6 Input Frequency Range : Taiwan/ or 45-55 Hz, 55-65 Hz, 45- Equivalent 65 Hz, 360-440 Hz Input Voltage: 110V, 100/√3V, 110V, 110/√3V, 230V, 400V Accuracy class: 0.2% Page 3 Sr Unit Total Cost Total Cost ITEMS Specification Qty GST Remarks # Rate without with GST Multi-Range: 60-120-300- Equivalent 600mA Scale: 120mm to 135mm with mirror under lay Accuracy: 2.5% 59. Ammeter AC/DC UK/ USA/ Japan/ 10 Portable Taiwan/ or Multi-Range: 60-120-300- Equivalent 600mA&1.2-3-6A Scale: 120mm to 135mm with mirror under lay Accuracy: 2.5% 60. Ammeter AC/DC UK/ USA/ Japan/ 5 Portable Taiwan/ or Multi-Range: 60-120-300- Equivalent 600mA&1.2-3-6A Scale: 120mm to 135mm with mirror under lay Accuracy: 2.5% 66. Thermocouple Wire K UK/ USA/ Japan/ 16 type 1600oC Taiwan/ or Equivalent 67. Bearing Puller ½” – 2.5” UK/ USA/ Japan/ 8 inner dia Taiwan/ or Equivalent 69. Spring Balance 50 Kg UK/ USA/ Japan/ 4 Taiwan/ or Equivalent Total Basic Lab No.2 - POWER LAB.NO.3 Page 4 Sr Unit Total Cost Total Cost ITEMS Specification Qty GST Remarks # Rate without with GST 3 Basic Electronic UK/ USA/ Japan/ 1 Trainer: Taiwan/ or To perform the following Equivalent experiments: Ohm’s law, Series and parallel resistive circuits, Electricity units and symbols, DC current, switches and relays, Power supplies and measuring instruments, Kirchhoff’s law, Laws combination of resistances, Faraday’s Law, Self inductance of coil, Laws of combination of capacitors, Power factor measurements, Measurement of power phase sequence, Measurement of reactive power, Measurement of Power factor improvement, Thevenin’s theorem, Superimposition theorem, Rheostats and 4 BasicPotentiometers, Electronic UK/ USA/ Japan/ 1 Trainer: Taiwan/ or For performing following Equivalent experiments: PN Junction Half and Full wave rectifiers Diode Characteristics, Voltage Doubler Zener Diode, Voltage Stabilization circuits Diode Limiters, Clipping and Clamping Circuits Use of UJT, SCR, Diac and Triaces NPN, PNP Transistors Use of FET and MOSFET, J-FET, Page 5 Sr Unit Total Cost Total Cost ITEMS Specification Qty GST Remarks # Rate without with GST 10 Galvanometer Portable: UK/ USA/ Japan/ 10 Current Sensitivity: Taiwan/ or 0.9A/div Equivalent Voltage Sensitivity: 540V/div Internal/External resistance 22 Watt hour Meter Single Pakistan/ China or 3 phase Analog: Equivalent Voltage: 220-240V Current: 10/40A Frequency: 50Hz 35 Ammeter AC/DC UK/ USA/ Japan/ 5 Portable: Taiwan/ or Multi-Range: 3-7.5-15- Equivalent 30A Scale: 120mm to 135mm with mirror under lay Accuracy: 2.5%. 36 Ammeter AC/DC UK/ USA/ Japan/ 5 Portable: Taiwan/ or Multi-Range: 3-7.5-15- Equivalent 30A Scale: 120mm to 135mm with mirror under lay Accuracy: 2.5%. 47 Battery Charger: UK/ USA/ Japan/ 4 Output Voltage: 12VDC, Taiwan/ or 8A Equivalent Input Voltage: 220VAC, 50Hz. 54 Syncroscope 96 x 96 UK/ USA/ Japan/ 4 Taiwan/ or Equivalent 57 Potentiometer/Resistanc UK/ USA/ Japan/ 4 e Substitution Box: Taiwan/ or Low Range: 15 to 10,000 Equivalent Ohms High Range: 15,000 to 10,000,000 Ohms Two 12-Step rotary switches allow selection of 24 values. Page 6 Sr Unit Total Cost Total Cost ITEMS Specification Qty GST Remarks # Rate without with GST 68 Spring Balance Capacity UK/ USA/ Japan/ 4 50kg Taiwan/ or Equivalent 69 AC Current Transducer: UK/ USA/ Japan/ 5 Input Current: 5A or 1A Taiwan/ or Accuracy class: 0.2% Equivalent Rated Frequency: 50 or 60Hz Burden: <0.5VA Output: 0-5, 0-20mA, 0-5, 0-10V 70 AC Voltage Transducer: UK/ USA/ Japan/ 5 Input Voltage: 100V, Taiwan/ or 100/3V, 110V, Equivalent 110/3V, 230V, 400V Accuracy class: 0.2% Output: 0-5, 0-20mA, 0-5, 0-10V 71 Power Line Transducer UK/ USA/ Japan/ 5 Taiwan/ or Equivalent 72 Frequency Transducer: UK/ USA/ Japan/ 5 Input Frequency Range: Taiwan/ or 45 – 55Hz, 55 – 65Hz, 45 Equivalent – 65Hz, 360 – 440Hz Input Voltage: 100V, 100/3V, 110V, 110/3V, 230V, 400V Accuracy Class: 0.2% Burden: <0.5VA Output measuring range: 0 – 200mA, 4 – 20mA, 0 – 10V 73 3-Phase Transducer 5kVA UK/ USA/ Japan/ 2 variable Taiwan/ or Equivalent 74 Single phase Transducer UK/ USA/ Japan/ 2 3kVA Taiwan/ or Equivalent 75 Current Transformer UK/ USA/ Japan/ 5 (portable): Taiwan/ or Page 7 Sr Unit Total Cost Total Cost ITEMS Specification Qty GST Remarks # Rate without with GST 77 Protection Relays UK/ USA/ Japan/ 2 (Analog / Digital): Taiwan/ or Study the operating Equivalent characteristics of the following protection relays: Atrracted Armature type relay, Buchholz’s relay , Plunger type relay, Induction over current relay, Induction reverse power relay, Induction relay, Impedance relay, Reactance relay, Beam relay, Frequency relay, Static relays, Amplitude- comparator relay, Phase comparator relay, Over voltage, Under voltage relay, Static over-current relay, Static distance relay, Differentials protection relay (Current balance, Voltage balance), Photoelectric relay, Thermal relay. 80 Motor winding machine Pakistan/ China or 2 (local) manual Equivalent Total Power Lab No.3 - Page 1 COMPARATIVE STATEMENT GCT TAXILA MECHANICAL TECHNOLOGY 1 BASIC MACHINE SHOP Sr Unit Total Rate Total ITEMS Specification Qty GST Remarks # Rate without Rate with 1 SHAPING MACHINE Pak Made or 2 (SHAPER) Equivalent Stroke length = 400-450mm No.