VICTUSVICTUS™ FemtosecondFemtosecond LaserLaser
1 Femtosecond Lasers
CornealCorneal CataractCataract (LASIK(LASIK Flap)Flap)
2 Femtosecond Lasers
CornealCorneal CataractCataract (LASIK(LASIK Flap)Flap) CataractCataract && CornealCorneal (LASIK(LASIK Flap)Flap) ProceduresProcedures
3 The VICTUS Platform
The VICTUS platform is cleared for creation of a corneal flap in patients undergoing LASIK surgery or other treatment requiring initial lamellar resection of the cornea, and for anterior capsulotomy during cataract surgery
4 VICTUS at a Glance
• Highly versatile – Cataract and corneal procedures in a single machine • Real-time, high-contrast OCT – Enables image-guided planning and monitoring • Curved patient interface controlled by Intelligent Pressure Sensors – Designed to minimize corneal folds
5 VICTUS Real-Time OCT For Planning & Monitoring
VICTUS
Other Femto Lasers
Planning Treatment Phase Phase
6 RealReal TimeTime OCTOCT
Aids centering of the eye
7 Curved Patient Interface
3-D cutting requires a static connection between laser and eye
• Anatomically designed for patient comfort • Sterile, disposable, single‐use
8 Intelligent Pressure Sensors
• Real-time monitoring of the curved patient interface with the eye via multiple pressure sensors • Designed to reduce applanation of the cornea and minimize corneal folds • Procedure-dependent pressure control – Stabilizes the eye for LASIK flap cutting – Unobstructed path of the laser beam through the cornea for capsulotomy
9 Intelligent Pressure Sensors
Intuitive User Interface
Regular pressure indicator (corneal procedures)
Unacceptable lateral force
Borderline acceptable lateral force
Acceptable lateral force
Soft pressure indicator (capsulotomy) No lateral force = uniform radial pressure
10 Procedure-Dependent Pressure Control
Procedure-Dependent Pressure Control • Anterior cornea/flap-cutting procedures – Pressure is optimized to provide a very stable corneal reference interface for precise depth control during the procedure • Capsulotomy – Pressure is optimized to avoid posterior corneal folds to enable a precise and complete cut Adjustable vacuum (20 mbar steps) • Secure placement of suction ring on eye
11 Fast Treatments
VICTUS LASIK Flap 160 kHz
VICTUS Cataract 80 kHz
LenSx Cataract1 33 kHz
Laser Pulse Rate Faster
1. LenSx K101626 510(k) documentation available at fda.gov 12 VICTUS Features and Benefits
13 Experience & Support
• Over 20 years’ experience developing and manufacturing optical lasers
• Modern manufacturing facility with Center of Excellence product training center in Munich, Germany
• Experienced support organization with more than 180 highly trained, certified application specialists and technical service engineers around the world
• Fast response times, personalized service, and clinical support via specialized local teams
14 VICTUS Intelligence Meets the Eye™
Cataract & Corneal Real-time OCT Stay in Control Applications Designed for •Versatility •Precision •Quality •Speed •Visualization Curved interface with Intelligent Pressure Sensors
High repetition/pulse rate laser source
15 ©2012 Bausch & Lomb Incorporated. BAUSCH + LOMB, VICTUS and Intelligence Meets the Eye are trademarks of Bausch & Lomb Incorporated.TECHNOLAS and INTRACOR are trademarks of Technolas Perfect Vision GmbH SU6798 8/12
16