The Potential and Challenges of Solar Boosted Heat Pumps for Domestic Hot Water Heating

Total Page:16

File Type:pdf, Size:1020Kb

The Potential and Challenges of Solar Boosted Heat Pumps for Domestic Hot Water Heating Solar Calorimetry Laboratory The Potential and Challenges of Solar Boosted Heat Pumps for Domestic Hot Water Heating Stephen Harrison Ph.D., P. Eng., Solar Calorimetry Laboratory, Dept. of Mechanical and Materials Engineering, Queen’s University, Kingston, ON, Canada Solar Calorimetry Laboratory Background • As many groups try to improve energy efficiency in residences, hot water heating loads remain a significant energy demand. • Even in heating-dominated climates, energy use for hot water production represents ~ 20% of a building’s annual energy consumption. • Many jurisdictions are imposing, or considering regulations, specifying higher hot water heating efficiencies. – New EU requirements will effectively require the use of either heat pumps or solar heating systems for domestic hot water production – In the USA, for storage systems above (i.e., 208 L) capacity, similar regulations currently apply Canadian residential sector energy consumption (Source: CBEEDAC) Solar Calorimetry Laboratory Solar and HP water heaters • Both solar-thermal and air-source heat pumps can achieve efficiencies above 100% based on their primary energy consumption. • Both technologies are well developed, but have limitations in many climatic regions. • In particular, colder ambient temperatures lower the performance of these units making them less attractive than alternative, more conventional, water heating approaches. Solar Collector • Another drawback relates to the requirement to have an auxiliary heat source to supplement the solar or heat pump unit, particularly, during cold or overcast periods. Roof Line Hot Water Hot Water to Load to Load Building Wall Glycol/water Auxiliary Anti-freeze Auxiliary Heater Outdoor Fan-coil Circulation Loop Heater Evaporator Water Water Compressor Storage Storage Heat Tank Tank Outdoor Exchanger Ambient Air Condenser Cold Mains Expansion Valve Water Inlet Cold Mains Water Inlet Electric Pump Electric Pump Electric Pump Split Heat Pump (optional) (optional) Solar Calorimetry Laboratory Compact Air-source HPWH Indoor Fan-coil Evaporator • The use of compact air-source heat pump water heaters (HPWHs) is well Ambient Air established. Hot Water to Load • Most draw heat from the surrounding environment and are best suited for mild climates where they may be placed outdoors or in an unheated garage. Auxiliary Heater • In cold regions, they must be located in a heated space to avoid high standby-losses or freezing, thereby shifting the water heating load to the space heating. • To alleviate this, “split systems” with outdoor fan-coil evaporators can be Wrap-around Condenser Cold Mains used or outdoor-air can be ducted into the indoor unit, however, cold Water Inlet outdoor temperatures can lower overall capacity and COP. Compact Heat Pump Water Heater Solar Calorimetry Laboratory WHY SB-HPWH HPWH Outdoor HPWH Indoor “Split” HPWH SB-HPWH Ambient Air Compressor Outdoor Ambient Air Expansion Valve Warm Climate Cold Climate Solar Calorimetry Laboratory Solar Boosted HPs Evaporator • Solar boosting HP output has been extensively studied and the benefits Solar Collector Roof Line in improved performance are well established but depend on climate Hot Water and the type of solar collector used. to Load Auxiliary Compressor Heater Water • Many configs: series vs parallel; direct and indirect; dual source etc. Storage Condenser Tank Expansion Valve Cold Mains • draw-backs to some SB-HPWH in terms of installation and operation, Water Inlet Heat Pump Electric Pump e.g., direct systems may need refrigeration connections on roof tops. (optional) • Indirect systems use conventional anti-freeze loops but require and an Solar additional pump Collector Roof Line • the most common configuration uses unglazed solar collectors that can Hot Water to Load collect ambient energy during low sun periods. Glycol/water Anti-freeze Auxiliary Circulation Loop Compressor Heater Water – These are simple and efficient but performance will drop during very Storage Evaporator Expansion Condenser Tank Valve cold or overcast periods. Cold Mains Water Inlet Electric Pump Heat Pump Electric Pump (optional) Solar Calorimetry Laboratory Motivation to Solar-boost a HP • Improvements to collector performance and HP COP • Cooling the solar collector Typical Efficiency Curves of Solar Collectors significantly improves its efficiency 1 • Increasing the HP’s evaporator 0.9 ΔT = 6, G=600W/mΔT = 230, G=600W/m2 temperature increases HP COP 0.8 0.7 ) • Collector area can be halved η 0.6 relative to Solar DHW. 0.5 0.4 • high-performance solar panels ( Efficiency 0.3 (with glazed and insulated 0.2 0.1 absorbers), may be used but limit 0 “non-solar”, air-source capacity; 0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 reducing their benefit. (Tf -Ta)/GT Unglazed Collector Single Glazed, Flat Plate Evacuated Tube Solar Calorimetry Laboratory Example Performance comparison 70 60 60 SAHP-Unglazed SAHP-Unglazed 50 50 • Freeman and Bridgeman studied an SAHP-Glazed 40 Indirect Solar-Assisted HPWH 40 HP Base SAHP-Glazed 30 30 • Compared performance for various 20 SDHW Solar Fraction (%) Fraction Solar Solar Fraction (%) Fraction Solar 20 climates, e.g., Toronto, Montreal and SDHW 10 Vancouver. 10 0 0 2 4 6 8 0 1 2 3 4 5 6 7 8 9 10 11 12 • Collector area and overall cost was 2 CollectorCollector Area Area (m2) (m ) Month of the Year reduced 65 100 SAHP-Unglazed • System performance was more Vancouver uniform over year. 60 80 Toronto 60 SAHP-Glazed • Identified need for variable capacity 55 Montreal Solar fraction versus collector 40 SDHW compressor to accommodate seasonal (%) Fraction Solar 50 area for unglazed SAHP systems. operation 20 CollectorEfficiency (%) 45 0 1 2 3 4 5 6 7 8 0 2 4 6 8 Collector Area (m2) CollectorCollector Area Area (m2) (m2) Solar Calorimetry Laboratory New Approaches to SB-HPWH • new systems are being studied that include dual- or tri-mode solar collectors that act as efficient solar- or air-source evaporators and may even include Photovoltaic/thermal absorbers. • Combined with new system configurations and components (e.g., Venting channel allows new variable speed, high-efficiency compressors), fully integrated, energy collection during low- high performance, solar/HP hybrid water heaters are possible. solar periods • PV/Thermal Panels offer many opportunities to “piggyback” on existing PV infrastructure (installation and mounting, etc.) • PV/Thermal panels offer high solar efficiency by delivering heat and electricity. Solar Boosted Heat Pump (Collector Options) Unglazed Solar Thermal Collector Unglazed Collector Dual Mode Vented Collector • By using an unglazed solar absorber it is • maximizes both ambient and solar possible to collect more heat from the ambient air (particularly during periods with a vented glazed solar collector with low solar input) however the solar that allow ambient air to circulate contribution will be less. next to the absorber plate • If collector temperature can be kept • The collector can reach higher very near or sub-ambient solar collector temperatures during sunny periods efficiency can be greater than 100%. (this was done for Team Ontario’s • The low temperature requirement may reduce heat pump COP and trade-off’s Solar Decathlon Entry, 2013) and need to be assessed. still draw heat from the ambient air. Solar Calorimetry Laboratory The Challenge: PV/Thermal HP Water heater • Solar conversion efficiency of PV/Thermal devices can be very high as solar energy, not directly converted to electricity, is converted to heat and this can be extracted for heating purposes. • The addition of a heat pump to this combination Direct power to allows solar panel operation at low temperatures Compressor or Grid (even sub-ambient) increasing both electric and Direct DC thermal conversion efficiency. PV-Thermal power to Modules TEM HP • The COP of the Heat pump “leverages” the Natural Anti-freeze Convection electrical input of the system while increasing the Collector Loop Loop To Load rs thermal output of the system o Auxiliary t c e ll Compressor Heating o • The successful integration of these systems, their C Element Hot water r r e o t s storage a RHPefr igerant n r controls and the utilization of the PV generated e o Loop d p SDHW n a o v E electricity are areas requiring research and C development. Electric Pump Expansion Valve Water Mains Supply PVT Solar Boosted HP vs Air Source Source PVT V-C HP DHW Sink 2 1950 퐅퐄퐑 = 2000 = 97.5% x 3 m 3 x 2 450+1500 퐄퐟퐟 1900 퐜퐨퐥 = 2400 = 81% 2 퐀퐫퐞퐚퐂퐨퐥퐥퐞퐜퐭퐨퐫 = 3 m = 2400 W 2400 = Heat = 2000 W 2000 = Heat 1900 퐂퐎퐏 퐇퐏 = 450 = 4.2 Example W/m800 = Solar Energy Flows for a heating Air-SOURCE HP DHW (Split system) load of 2 kW AC Grid 650 W 1450 퐅퐄퐑 = 2000 = 72.5% 1900 Air- 1900 퐂퐎퐏 퐇퐏 = 650 = 2.9 source 1450 W W 2000 = Heat Outdoor Ambient Air Ambient Outdoor Solar Calorimetry Laboratory Competing Water Heating Options Domestic Hot Water Heating Approaches Storage Heaters On Demand (no storage) Traditional Solar PV Solar Thermal Central Home PV HP power fans, ICS (Integral Oil/Gas Fueled Heat Pump compressor etc. Collector Storage) Point of use Oil/gas and electric PV Power Electric Air Source HP Solar Source HP resistance Electric Resistance Resistance Htr. Split System Direct/Series Direct/No Freeze (Solar Evaporator) Protection Integrated System Indirect/Series Indirect/Freeze Heat Loop Protected Parallel System PV/Thermal Solar Panels (2 & 3 Mode) Solar Calorimetry Laboratory Conclusion • As energy efficiency in buildings increases, space heating requirements may be reduced through improved building practices • In the limit domestic hot water heating will persist as a significant load and major contributor to peak load demands. • to be competitive Solar Boosted Heat Pumps must be able to Thank you! deliver: – high temps, energy efficiency, ease of installation, good cost performance, load shifting. • There is tremendous potential but still work to do! Solar Calorimetry Laboratory Questions: a) Is there a role for PV/Thermal technology for HPWH? b) Can solar boosted PVT HPWHs “piggyback” on PV infrastructure to accelerate deployment? b) Should PVT-HPWHs send power to the “grid” or self-power?.
Recommended publications
  • Best Practices in Central Heat Pump Water Heating
    MAR 2018 Heat Pumps Are Not Boilers ACEEE – HOT WATER FORUM 2018 | Shawn Oram, PE, LEED AP Director of Engineering & Design ECOTOPE.COM • OVERVIEW • END GAME • WHAT’S AVAILABLE NOW • PROBLEMS WE ARE SEEING • MARKET DEVELOPMENT NEEDS • QUESTIONS AGENDA ECOTOPE.COM 2 Common Space Heat, Seattle 2014 Benchmarking Data 5 DHW Heat, 10 Median EUI (kBtu/SF/yr) Unit Space 1/3 OF THE LOAD IS Heat, 5 TEMPERATURE MAINTAINANCE Lowrise EUI = 32 Unit Non- Common Heat, 10 Non-Heat, Midrise EUI = 36 10 2009 Multifamily EUI (KBTU/Sf/Yr) Highrise EUI = 51 Breakdown By Energy End Use Type MULTIFAMILY ENERGY END USES ECOTOPE.COM 3 “Heat Pumps Move Heat” Optimize storage design to use coldest water possible HEAT PUMP WATER HEATING ECOTOPE.COM 4 R-717 0 BETTER CO2 Variable Capacity | SANDEN, R-744 1 MAYEKAWA, MITSUBISHI Eco-Cute R-1270 2 GWP OF SELECTED REFRIGERANTS R-290 3 (Carbon Dioxide Equivalents, CO2e) R-600a 3 Proposed HFO replacement refrigerant R-1234yf 4 R-1150 4 R-1234ze 6 Refrigerants have 10% of the climate R-170 6 forcing impact of CO2 Emissions R-152a 124 Fixed Capacity| MOST HPWH’s R-32 675 COLMAC, AO SMITH R-134a 1430 R-407C 1744 Variable Capacity | PHNIX, R-22 1810 ALTHERMA, VERSATI R-410A 2088 Fixed Capacity| AERMEC R-125 3500 R-404A 3922 R-502 4657 WORSE R-12 10900 REFRIGERANT TYPES ECOTOPE.COM 5 • No Refrigerant • 20-30% Less Energy • Quiet • GE/Oak Ridge Pilot • Ready for Market -2020 MAGNETO-CALORIC HEAT PUMP ECOTOPE.COM 6 140˚ 120˚ HOT WATER HEAT PUMP HOT WATER HEAT PUMP STORAGE WATER STORAGE WATER HEATER HEATER 50˚ 110˚ Heat the water up to usable Heat the water up 10-15 degrees temp in a single pass.
    [Show full text]
  • Clean Coil Program
    TM CLEAN COIL PROGRAM There are many good reasons to clean coils! And, here is what the Nu-Calgon Clean Coil & IAQ Assurance Program can do for you... Gain significant savings on energy costs. Maintain peak operating efficiency. Enhance the cooling system’s reliability and service life. Prevent costly breakdowns. Improve Indoor Air Quality (IAQ). Backed by Nu-Calgon, the leader in HVAC and Refrigeration maintenance chemicals for more than 60 years. www.nucalgon.com l www.coilcleaning.com l www.coilprotection.com NU-CALGON CLEAN COIL & IAQ ASSURANCE PROGRAM FOR AIR CONDITIONING, REFRIGERATION SYSTEMS Over the last 50 years, Nu-Calgon has developed products that have proven themselves in the successful cleaning and protection of air conditioning and refrigeration equipment. Now, these products have been further developed into a program that will keep this equipment operating efficiently and effectively, thereby cutting electric bills, increasing the equipment’s service life, and improving the comfort and Indoor Air Quality of the building or home. An air conditioning or refrigeration system has two “finned” coils, and typically they are constructed of copper tube and aluminum fins. The evaporator coil is the indoor coil, usually referred to as the “A” coil in residential systems. It could be described as “cold” as it provides indoor cooling by absorbing the heat as a fan passes the building air over it. The condenser coil or outdoor coil is the coil that is “warm” as it rejects the heat as a fan blows outdoor air across it. These coils are sized to match the Btu cooling load or requirement of the home or building, and they are engineered for maximum heat transfer .
    [Show full text]
  • Indoor Air Quality Products Offering Healthy Home Solutions
    Indoor Air Quality Products Offering Healthy Home Solutions Carrier clears the air for enhanced indoor comfort What You Can Expect From Carrier Innovation, efficiency, quality: Our Carrier® Healthy Home Solutions offers superior control over the quality of your indoor air and as a result, improved comfort. From air purification and filtration to humidity control, ventilation and more, these products represent the Carrier quality, environmental stewardship and lasting durability that have endured for more than a century. In 1902, that’s the year a humble but determined engineer solved one of mankind’s most elusive challenges – controlling indoor comfort. A leading engineer of his day, Dr. Willis Carrier would file more than 80 patents over the course of his career. His genius would enable incredible advancements in health care, manufacturing processes, food preservations, art and historical conservation, indoor comfort and much more. Carrier’s foresight changed the world forever and paved the way for over a century of once-impossible innovations. Designed with Your Comfort in Mind Carrier® Healthy Home Solutions represents years of design, development and testing with one goal in mind – maximizing your family’s comfort. Along the way, we have taken the lead with new technologies that deliver the superior performance you demand while staying ahead of industry trends and global initiatives. With innovations like Captures & Kills™ technology and superior humidity and airflow control, whatever your need, Carrier has a solution that’s perfectly tailored for you. 2 Ready to Clear the Air? The EPA has found that indoor levels of many air pollutants are often higher than outdoor levels.
    [Show full text]
  • Refrigerant Selection and Cycle Development for a High Temperature Vapor Compression Heat Pump
    Refrigerant Selection and Cycle Development for a High Temperature Vapor Compression Heat Pump Heinz Moisia*, Renè Riebererb aResearch Assistant, Institute of Thermal Engineering, Graz University of Technology, Inffeldgasse 25/B, 8010 Graz, Austria bAssociate Professor, Institute of Thermal Engineering, Graz University of Technology, Inffeldgasse 25/B, 8010 Graz, Austria Abstract Different technological challenges have to be met in the course of the development of a high temperature vapor compression heat pump. In certain points of operation, high temperature refrigerants can show condensation during the compression which may lead to compressor damage. As a consequence, high suction gas superheat up to 20 K can be necessary. Furthermore high compressor outlet temperatures caused by high heat sink outlet temperatures (approx. 110 °C) and high pressure ratios can lead to problems with the compressor lubricant. In order to meet these challenges different refrigerant and cycle configurations have been investigated by means of simulation. Thermodynamic properties as well as legal and availability aspects have been considered for the refrigerant selection. The focus of the cycle configurations has been set on the realization of the required suction gas superheat. Therefore the possibility of an internal heat exchanger and a suction gas cooled compressor has been investigated. The simulation results showed a COP increase of up to +11 % due to the fact that the main part of the suction gas superheat has not been provided in the evaporator. Furthermore, the effect of increased subcooling has been investigated for a single stage cycle with internal heat exchanger. The results showed a COP of 3.4 with a subcooling of 25 K at a temperature lift of approximately 60 K for the refrigerant R600 (n-butane).
    [Show full text]
  • High Temperature Heat Pump Using HFO and HCFO Refrigerants
    Purdue University Purdue e-Pubs International Refrigeration and Air Conditioning School of Mechanical Engineering Conference 2018 High temperature heat pump using HFO and HCFO refrigerants - System design, simulation, and first experimental results Cordin Arpagaus NTB University of Applied Sciences of Technology Buchs, Switzerland, [email protected] Frédéric Bless NTB University of Applied Sciences of Technology Buchs, Institute for Energy Systems, Werdenbergstrasse 4, 9471 Buchs, Switzerland, [email protected] Michael Uhlmann NTB University of Applied Sciences in Buchs, Switzerland, [email protected] Elias Büchel NTB University of Applied Sciences of Technology Buchs, Institute for Energy Systems, Werdenbergstrasse 4, 9471 Buchs, Switzerland, [email protected] Stefan Frei NTB University of Applied Sciences of Technology Buchs, Institute for Energy Systems, Werdenbergstrasse 4, 9471 Buchs, Switzerland, [email protected] See next page for additional authors Follow this and additional works at: https://docs.lib.purdue.edu/iracc Arpagaus, Cordin; Bless, Frédéric; Uhlmann, Michael; Büchel, Elias; Frei, Stefan; Schiffmann, Jürg; and Bertsch, Stefan, "High temperature heat pump using HFO and HCFO refrigerants - System design, simulation, and first experimental results" (2018). International Refrigeration and Air Conditioning Conference. Paper 1875. https://docs.lib.purdue.edu/iracc/1875 This document has been made available through Purdue e-Pubs, a service of the Purdue University Libraries. Please contact [email protected]
    [Show full text]
  • Cooling Towers and Condenser Water Systems Design and Operation
    a Trane Engineers Newsletter Live Cooling Towers and Condenser Water Systems: Design and Operation • 2005 Cooling Towers and Condenser Water Systems Design and Operation an Engineers Newsletter Live telecast © 2005 American Standard Inc. Today’s Topics Fundamentals Chiller–tower interaction Cooling-tower terminology, operation Design conditions Cooling-tower control options System optimization © 2005 Standard Inc. American Answers to your questions © 2018 Trane a business of Ingersoll Rand. All rights reserved Trane, in proposing these system design and application concepts, assumes no responsibility for the performance or desirability of any 1 resulting system design. Design of the HVAC system is the prerogative and responsibility of the engineering professional. a Trane Engineers Newsletter Live Cooling Towers and Condenser Water Systems: Design and Operation • 2005 Today’s Presenters Dave Mick Lee Cline © 2005 Standard Inc. American Guckelberger Schwedler systems applications applications marketing engineer engineer engineer Cooling Towers and Condenser Water Systems Design and Operation Cooling tower fundamentals © 2005 American Standard Inc. © 2018 Trane a business of Ingersoll Rand. All rights reserved Trane, in proposing these system design and application concepts, assumes no responsibility for the performance or desirability of any 2 resulting system design. Design of the HVAC system is the prerogative and responsibility of the engineering professional. a Trane Engineers Newsletter Live Cooling Towers and Condenser Water Systems: Design and Operation • 2005 Refrigeration Cycle 2-stage compressor evaporator condenser economizer © 2005 Standard Inc. American expansion expansion device device Pressure–Enthalpy (p-h) Chart subcooled liquid liquid + vapor mix superheated pressure A B vapor 5 psia © 2005 Standard Inc. American 15.5 Btu/lb enthalpy 92.4 Btu/lb © 2018 Trane a business of Ingersoll Rand.
    [Show full text]
  • Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida
    BUILDING TECHNOLOGIES OFFICE Building America Case Study Technology Solutions for New and Existing Homes Performance of a Heat Pump Water Heater in the Hot-Humid Climate Windermere, Florida Over recent years, heat pump water heaters (HPWHs) have become more read- PROJECT INFORMATION ily available and more widely adopted in the marketplace. A key feature of an Project Name: Systems Evaluation at HPWH unit is that it is a hybrid system. When conditions are favorable, the unit the Cool Energy House will operate in heat pump mode (using a vapor compression system that extracts Location: Windermere, FL heat from the surrounding air) to efficiently provide domestic hot water (DHW). Partners: Homeowners need not adjust their behavior to conform to the heat pump’s Southern Traditions Development capabilities. If a heat pump cannot meet a higher water draw demand, the heater http://southerntraditionsdev.com/ will switch to electric resistance to provide a higher heating rate. This flexibility Consortium for Advanced provides the energy savings of heat pump mode (when possible) while perform- Residential Buildings www.carb-swa.com ing as an electric resistance water heater (ERWH) during periods of high DHW demand. Furthermore, an HPWH’s operational byproduct is cooling and dehu- Building Component: Domestic hot water midification, which can be particularly beneficial in hot-humid climates. Application: Retrofit, single family For a 6-month period, the Consortium for Advanced Residential Buildings, a Year Tested: 2012 U.S. Department of Energy Building America team, monitored the performance Applicable Climate Zone(s): Hot-humid of a GE Geospring HPWH in Windermere, Florida. The study included hourly energy simulation analysis using the National Renewable Energy Laboratory’s PERFORMANCE DATA Building Energy Optimization-Energy Plus (BEopt) v1.3 software.
    [Show full text]
  • Design of a Heat Pump Assisted Solar Thermal System Kyle G
    Purdue University Purdue e-Pubs International High Performance Buildings School of Mechanical Engineering Conference 2014 Design of a Heat Pump Assisted Solar Thermal System Kyle G. Krockenberger Purdue University, United States of America / Department of Mechanical Engineering Technology, [email protected] John M. DeGrove [email protected] William J. Hutzel [email protected] J. Christopher Foreman [email protected] Follow this and additional works at: http://docs.lib.purdue.edu/ihpbc Krockenberger, Kyle G.; DeGrove, John M.; Hutzel, William J.; and Foreman, J. Christopher, "Design of a Heat Pump Assisted Solar Thermal System" (2014). International High Performance Buildings Conference. Paper 146. http://docs.lib.purdue.edu/ihpbc/146 This document has been made available through Purdue e-Pubs, a service of the Purdue University Libraries. Please contact [email protected] for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html 3572 , Page 1 Design of a Heat Pump Assisted Solar Thermal System Kyle G. KROCKENBERGER 1*, John M. DEGROVE 1*, William J. HUTZEL 1, J. Chris FOREMAN 2 1Department of Mechanical Engineering Technology, Purdue University, West Lafayette, Indiana, United States. [email protected], [email protected], [email protected] 2Department of Electrical and Computer Engineering Technology, Purdue University, West Lafayette, Indiana, United States. [email protected] * Corresponding Author ABSTRACT This paper outlines the design of an active solar thermal loop system that will be integrated with an air source heat pump hot water heater to provide highly efficient heating of a water/propylene glycol mixture.
    [Show full text]
  • Plate Heat Exchangers for Refrigeration Applications
    Plate heat exchangers for refrigeration applications Technical reference manual A Technical Reference Manual for Plate Heat Exchangers in Refrigeration & Air conditioning Applications by Dr. Claes Stenhede/Alfa Laval AB Fifth edition, February 2nd, 2004. Alfa Laval AB II No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, recording, or otherwise, without the prior written permission of Alfa Laval AB. Permission is usually granted for a limited number of illustrations for non-commer- cial purposes provided proper acknowledgement of the original source is made. The information in this manual is furnished for information only. It is subject to change without notice and is not intended as a commitment by Alfa Laval, nor can Alfa Laval assume responsibility for errors and inaccuracies that might appear. This is especially valid for the various flow sheets and systems shown. These are intended purely as demonstrations of how plate heat exchangers can be used and installed and shall not be considered as examples of actual installations. Local pressure vessel codes, refrigeration codes, practice and the intended use and in- stallation of the plant affect the choice of components, safety system, materials, control systems, etc. Alfa Laval is not in the business of selling plants and cannot take any responsibility for plant designs. Copyright: Alfa Laval Lund AB, Sweden. This manual is written in Word 2000 and the illustrations are made in Designer 3.1. Word is a trademark of Microsoft Corporation and Designer of Micrografx Inc. Printed by Prinfo Paritas Kolding A/S, Kolding, Denmark ISBN 91-630-5853-7 III Content Foreword.
    [Show full text]
  • Refined Comfort
    REFINED COMFort Dehumidification Systems FOR COMMERCIAL ROOFTOP UNITS AND SPLIT SYSTEMS Superior humidity and temperature control every day of the year With the Humiditrol® dehumidification system from Lennox, you can easily reduce humidity levels regardless of room temperature. The unique dehumidification-on-demand design removes moisture based on relative humidity levels—not the temperature—so it’s easy and efficient to create a better indoor environment. Why the Humiditrol® dehumidification system is more effective The Humiditrol dehumidification system is different from standard dehumidification HUMIDITROL® products that use cooling to remove moisture. That method can backfire by overcooling DEHUMIDIFICATION the space and leading to condensation and mold growth, even damaging building AT A GLANCE: materials. The Humiditrol system removes moisture with minimal effect on temperature, avoiding problems with overcooling. Integrated dehumidification system that controls humidity independent of room temperature Reduced humidity is better for business Available on rooftop units and small split systems High humidity levels can make Indoor air quality people feel sticky and may create productivity costs Efficiently improves indoor air a breeding ground for mold, quality (IAQ) and comfort mildew, dust mites and bacteria. Estimated number of employees 65 This environment not only affects Salary cost (per average employee) $30,000 Reduces spread of allergens such as customer comfort, but can also mold, mildew and dust mites Total staff (yearly) $1,950,000 compromise the integrity of Productivity losses due to poor computers and electronics, building thermal comfort, absenteeism, 3% Helps control mold-related repair comfort, etc. (average %) and maintenance costs materials and stocked items. Total lost productivity $58,500 Maintaining relative humidity Rooftop unit system removes up to Information from “Humidity Control, IAQ and You” Engineered Systems magazine, January 2001.
    [Show full text]
  • Evaporator System Basics
    Evaporator System Basics Today, more than ever, the cost of energy evaporator is always in liquid form and remains in represents a very significant part of the cost of liquid form even after the water is evaporated. operating a rendering plant. The recent rapid rise in energy costs has caused rendering plant The physical process of evaporation requires the operators to look for ways of improving the input of energy in the form of heat to convert a energy efficiency of plant operations. There are liquid into vapor. Since all evaporators use the many ways of accomplishing this goal, and one process of evaporation to remove water, every of the most effective ways is to use the energy evaporator requires a source of heat to operate. present the in waste vapor from the cooking The heat source for almost all evaporators is water operation. By using a waste heat evaporator, this vapor, either in the form of boiler steam or waste energy can be used to help evaporate the water in vapor from another process. the raw material prior to the cooker. The result is A second requirement for all evaporators is a a reduction in the amount of boiler steam required means to transfer heat energy from the heat source to cook the raw material and a corresponding into the evaporator liquid. Most evaporators increase in energy efficiency. use a tubular heater called a shell and tube heat The use of an evaporator is key in implementing exchanger for this purpose. In the heat exchanger this strategy. The following article outlines the shell, water vapor condenses on the outside of basics of evaporators and offers some guidance in the tubes thus giving up its heat energy, called choosing a suitable evaporator configuration.
    [Show full text]
  • Review of Temperature and Humidity Control Technology for Heat Pump and Air Conditioning Systems
    Purdue University Purdue e-Pubs International Refrigeration and Air Conditioning School of Mechanical Engineering Conference 2016 Review of Temperature and Humidity Control Technology for Heat Pump and Air Conditioning Systems Xiaojie Lin University Of Maryland, United States of America, [email protected] Yunho Hwang University Of Maryland, United States of America, [email protected] Reinhard Radermacher University Of Maryland, United States of America, [email protected] Saikee Oh University Of Maryland, United States of America, [email protected] Follow this and additional works at: http://docs.lib.purdue.edu/iracc Lin, Xiaojie; Hwang, Yunho; Radermacher, Reinhard; and Oh, Saikee, "Review of Temperature and Humidity Control Technology for Heat Pump and Air Conditioning Systems" (2016). International Refrigeration and Air Conditioning Conference. Paper 1727. http://docs.lib.purdue.edu/iracc/1727 This document has been made available through Purdue e-Pubs, a service of the Purdue University Libraries. Please contact [email protected] for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html 2386, Page 1 Review of Temperature and Humidity Control Technology for Heat Pump and Air Conditioning Systems Xiaojie LIN1, Yunho HWANG1*, Reinhard RADERMACHER1, Saikee OH2 1Center for Environmental Energy Engineering, University of Maryland, 4164 Glenn L. Martin Hall Bldg., College Park, MD 20742, USA 2System Air Conditioning Laboratory, LG Electronics, 327-23, Gasan-Dong, Geumcheon-gu, Seoul, 153-802, Republic of Korea *: Corresponding Author, Tel: (301) 405-5247, E-mail: [email protected] ABSTRACT Indoor temperature and humidity are the two most significant factors to occupants’ thermal comfort.
    [Show full text]