Non-Intrusive Current Sensing With

Total Page:16

File Type:pdf, Size:1020Kb

Non-Intrusive Current Sensing With NON-INTRUSIVE CURRENT SENSING WITH GIANT MAGNETORESISTANCE SENSORS FOR POWER DISTRIBUTION MONITORING A Thesis Presented to the Faculty of San Diego State University In Partial Fulfillment of the Requirements for the Degree Master of Science in Electrical Engineering by Jonathan Thomas Hammer Fall 2018 iii Copyright c 2018 by Jonathan Thomas Hammer All Rights Reserved iv DEDICATION Dedicated to my family. v However difficult life may seem, there is always something you can do and succeed at. – Stephen Hawking vi ABSTRACT OF THE THESIS Non-Intrusive Current Sensing with Giant Magnetoresistance Sensors for Power Distribution Monitoring by Jonathan Thomas Hammer Master of Science in Electrical Engineering San Diego State University, 2018 With accelerating Smart Grid and automated Smart Building technologies, there is an ever-increasing demand for non-invasive, networked load monitoring. Magnetometers leveraging Giant Magnetoresistance (GMR) can be used to measure electrical currents via their inherent magnetic fields. Research is conducted to characterize these sensors and investigate their usefulness in a wireless embedded system for the purposes of energy management in power distribution equipment. An example embedded system design is proposed as a non-intrusive power monitoring solution. The goal of such a system is that it can be installed without opening the electrical equipment or removing the faceplate, so that power management can be employed without requiring qualified electricians. This work investigates realistic scenarios for employing GMR sensors in power distribution load centers with multiple circuits. Research is done to assess how multiple current sources create magnetic fields in panelboards, and how an array of GMR-based magnetic field sensors may be used to capture power load events. Methods for collecting and processing multi-channel sensor data are discussed, particularly techniques for eliminating signal crosstalk between the channels. Through several experiments on two purpose-built testbeds, a calibration method is developed for the sensor array. Using the calibrated sensor array, measurements of electrical currents are made with a percent error ranging from 0.82% to 15.88% for active loads. vii TABLE OF CONTENTS PAGE ABSTRACT .................................................................................... vi LIST OF TABLES.............................................................................. ix LIST OF FIGURES ............................................................................ x GLOSSARY .................................................................................... xiii ACKNOWLEDGMENTS ..................................................................... xvi CHAPTER 1 INTRODUCTION ..................................................................... 1 1.1 Submeter Load Monitoring ..................................................... 1 1.2 Non-invasive Energy Management ............................................. 2 1.3 Magnetoresistance .............................................................. 4 1.4 Sensing Current ................................................................. 9 1.5 Measuring Power................................................................ 9 2 DISCOVERY........................................................................... 11 2.1 Ratiometric Response ........................................................... 11 2.2 Front-End Circuit Design ....................................................... 13 2.3 Omnipolar Response ............................................................ 14 2.4 Model............................................................................ 16 2.5 Circuit Breaker Form Factor .................................................... 17 3 EXPERIMENTS ....................................................................... 19 3.1 Test Bench 1 ..................................................................... 19 3.2 Test Bench 2 ..................................................................... 22 3.2.1 Load Sequence Test ....................................................... 26 3.2.2 Simultaneous Loads Test .................................................. 29 3.2.3 Simultaneous Loads Test with Differing Loads .......................... 32 4 CORRECTION TECHNIQUES ...................................................... 34 4.1 Orientation....................................................................... 34 4.2 Sensitivity Matrix Calibration .................................................. 37 4.2.1 Calibration Steps........................................................... 39 viii 4.2.2 Inverse Sensitivity Matrix Correction Results............................ 40 4.3 Independent Component Analysis.............................................. 47 5 EMBEDDED DEVELOPMENT...................................................... 52 5.1 Design ........................................................................... 52 5.2 Applications ..................................................................... 54 6 Conclusion and Future Work .......................................................... 56 BIBLIOGRAPHY .............................................................................. 57 APPENDIX SENSOR ARRAY CALIBRATION ARTIFACTS ....................................... 60 ix LIST OF TABLES PAGE 2.1 Ratiometric Response of GMR Sensor................................................ 12 2.2 Ratiometric Saturation of GMR Sensor ............................................... 12 4.1 Summary of GMR Sensor Orientation Analysis ..................................... 37 4.2 Current Measurement at n = 5300 (Quiescent) from Simultaneous Loads Test with Differing Loads ...................................................... 45 4.3 Current Measurement at n = 7300 from Simultaneous Loads Test with Differing Loads ........................................................................ 45 4.4 Current Measurement at n = 9300 from Simultaneous Loads Test with Differing Loads ........................................................................ 45 4.5 Current Measurement at n = 11300 from Simultaneous Loads Test with Differing Loads ........................................................................ 46 A.1 Scaling Vector from Load Sequence Test ............................................. 61 A.2 Sensitivity Matrix from Load Sequence Test ......................................... 62 x LIST OF FIGURES PAGE 1.1 Current transformers for measuring current. (Left) Electricians hand- held clamp meter [11]. (Right) Split-core current transformer [12]. ............... 3 1.2 Line splitter for plug load monitoring with current clamp [14]. .................... 4 1.3 Eaton Smart Breaker [18]. Below the Eaton logo reads “REMOTELY OPERATED OVER WIFI”. ........................................................... 5 1.4 Layers of GMR composite material. The outer layers are ferromagnetic (FM) and the inner layer is nonmagnetic (NM). The Ferromagnetic (FM) layers have antiparallel magnetic moments. All electrons in the non- magnetic (NM) conduction layer are subjected to strong scattering in absence of external magnetic field. ................................................... 5 1.5 GMR material in presence of external magnetic fields. (Left) External magnetic field oriented up causes ferromagnetic (FM) layers to align up and reduces the scattering of electrons with up spin in the nonmagnetic (NM) conduction layer. (Right) External magnetic field oriented down causes FM layers to align down and reduces scattering of electrons with down spin in the NM conduction layer. .............................................. 7 1.6 Resistance of GMR material versus applied magnetic field [21]. Notice the omnipolar response. ............................................................... 8 1.7 (Left) SOIC8 packaged GMR sensor and (Right) Functional diagram of GMR sensor [21]. The axis of sensitivity to magnetic fields is parallel to the plane. ............................................................................ 8 2.1 Schematic of front end-amplifier circuit for GMR current sensor. The GMR sensor is internally configured as a Wheatstone half-bridge. ................ 13 2.2 GMR sensor output voltage versus external magnetic field in Oersteds [29]. An omnipolar response is shown. Notice the hysteresis, which places two aliases of the response about the origin. ................................. 14 2.3 Oscilloscope capture of four GMR current sensor outputs. The operat- ing point allows the center of the “V” to be crossed, leading to reduced linearity and malformed sine waves. ................................................. 15 2.4 Various DC magnetic operating points of the GMR sensor [28]. The magnetic bias is indicated by (p). (a) shows no magnetic bias. (b) shows a slight magnetic bias. (c) shows enough magnetic bias to prevent signal distortion. .............................................................................. 16 xi 2.5 Cross section of Eaton BR 15A breaker [31]. Annotated is the place- ment of a stick-on GMR sensor and the theoretical magnetic field of the current in the conductor. .............................................................. 18 3.1 Experiment 1 Test Bench. Two circuits are loaded with various settings of a “dummy load” resistor box along with multiple combinations of heat lamps to vary the load. ........................................................... 20 3.2 GMR Sensors directly on conductor, arranged perpendicular to each other.
Recommended publications
  • Current Measurement in Power Electronic and Motor Drive Applications - a Comprehensive Study
    Scholars' Mine Masters Theses Student Theses and Dissertations Fall 2007 Current measurement in power electronic and motor drive applications - a comprehensive study Asha Patel Follow this and additional works at: https://scholarsmine.mst.edu/masters_theses Part of the Electrical and Computer Engineering Commons Department: Recommended Citation Patel, Asha, "Current measurement in power electronic and motor drive applications - a comprehensive study" (2007). Masters Theses. 4581. https://scholarsmine.mst.edu/masters_theses/4581 This thesis is brought to you by Scholars' Mine, a service of the Missouri S&T Library and Learning Resources. This work is protected by U. S. Copyright Law. Unauthorized use including reproduction for redistribution requires the permission of the copyright holder. For more information, please contact [email protected]. CURRENT MEASUREMENT IN POWER ELECTRONIC AND MOTOR DRIVE APPLICATIONS – A COMPREHENSIVE STUDY by ASHABEN MEHUL PATEL A THESIS Presented to the Faculty of the Graduate School of the UNIVERSITY OF MISSOURI-ROLLA In Partial Fulfillment of the Requirements for the Degree MASTER OF SCIENCE IN ELECTRICAL ENGINEERING 2007 Approved by _______________________________ _______________________________ Dr. Mehdi Ferdowsi, Advisor Dr. Keith Corzine ____________________________ Dr. Badrul Chowdhury © 2007 ASHABEN MEHUL PATEL All Rights Reserved iii ABSTRACT Current measurement has many applications in power electronics and motor drives. Current measurement is used for control, protection, monitoring, and power management purposes. Parameters such as low cost, accuracy, high current measurement, isolation needs, broad frequency bandwidth, linearity and stability with temperature variations, high immunity to dv/dt, low realization effort, fast response time, and compatibility with integration process are required to ensure high performance of current sensors.
    [Show full text]
  • Use of Hall Effect Sensors for Protection and Monitoring Applications March 2018 Use of Hall Effect Sensors for Protection and Monitoring Applications
    PSRC I24 Use of Hall Effect Sensors for Protection and Monitoring Applications March 2018 Use of Hall Effect Sensors for Protection and Monitoring Applications A report to the Relaying Practices Subcommittee I Power System Relaying and Control Committee IEEE Power & Energy Society Prepared by Working Group I-24 Working Group Assignment Report on the use of Hall Effect Sensors for Protection and Monitoring Applications. The report will discuss the technology, and compare with other sensing technologies. Working Group Members Jim Niemira – Chair Jeff Long – Vice Chair Jeff Burnworth John Buffington Amir Makki Mario Ranieri George Semati Alex Stanojevic Mark Taylor Phil Zinck Page 1 of 32 PSRC I24 Use of Hall Effect Sensors for Protection and Monitoring Applications March 2018 TABLE OF CONTENTS Working Group Assignment .......................................................................................................................... 1 Working Group Members ............................................................................................................................. 1 1 Introduction .......................................................................................................................................... 5 2 Theory – What is Hall Effect .................................................................................................................. 5 3 Current Sensing Hall Effect Sensors ...................................................................................................... 6 4 Sensor Types
    [Show full text]
  • Introduction to Magnetic Current Sensing.Pdf
    Introduction to Magnetic Current Sensing TI Precision Labs – Magnetic Sensors Presented and prepared by Ian Williams 1 Hello, and welcome to the TI precision labs series on magnetic sensors. My name is Ian Williams, and I’m the applications manager for current sensing products. In this video, we will give an introduction to magnetic current sensing, including: a comparison of direct vs. indirect sensing, review of Ampere’s law, and overview of different magnetic current sensing technologies. 2 Direct (shunt-based) current sensing • Things to know: – Based on Ohm’s law – Shunt resistor in series with load – Invasive measurement RSHUNT adds to system load Iload – Sensing circuit not isolated from system load • Recommend when: + + Vshunt R shunt + – Currents are < 100A - • Higher currents possible with appropriate shunt resistor and Vo design techniques - – System can tolerate power loss P = I2R – Low voltage 100V or less GND – Load current not very dynamic – Isolation not required (though it can be accomplished) See: TI Precision Labs – Current Sense Amplifiers 2 Direct, or shunt-based, current sensing is based on Ohm’s law. By placing a shunt resistor in series with the system load, a voltage is generated across the shunt resistor that is proportional to the system load current. The voltage across the shunt can be measured by differential amplifiers such as current sense amplifiers (CSAs), operational amplifiers (op amps), difference amplifiers (DAs), or instrumentation amplifiers (IAs). This method is an invasive measurement of the current since the shunt resistor and sensing circuitry are electrically connected to the monitored system. Therefore, direct sensing typically is used when galvanic isolation is not required, although isolated devices are available.
    [Show full text]
  • A Current Sensor Based on the Giant Magnetoresistance Effect: Design and Potential Smart Grid Applications
    Sensors 2012, 12, 15520-15541; doi:10.3390/s121115520 OPEN ACCESS sensors ISSN 1424-8220 www.mdpi.com/journal/sensors Article A Current Sensor Based on the Giant Magnetoresistance Effect: Design and Potential Smart Grid Applications Yong Ouyang 1, Jinliang He 1,*, Jun Hu 1 and Shan X. Wang 1,2 1 State Key Lab of Power Systems, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China; E-Mails: [email protected] (Y.O.Y.); [email protected] (J.H.) 2 Center for Magnetic Nanotechnology, Stanford University, 450 Serra Mall, Stanford, CA 94305, USA; E-Mail: [email protected] * Author to whom correspondence should be addressed; E-Mail: [email protected]; Tel.: +86-10-6278-8811; Fax: +86-10-6278-4709. Received: 27 September 2012; in revised form: 29 October 2012 / Accepted: 30 October 2012 / Published: 9 November 2012 Abstract: Advanced sensing and measurement techniques are key technologies to realize a smart grid. The giant magnetoresistance (GMR) effect has revolutionized the fields of data storage and magnetic measurement. In this work, a design of a GMR current sensor based on a commercial analog GMR chip for applications in a smart grid is presented and discussed. Static, dynamic and thermal properties of the sensor were characterized. The characterizations showed that in the operation range from 0 to ±5 A, the sensor had a sensitivity of 28 mV·A−1, linearity of 99.97%, maximum deviation of 2.717%, frequency response of −1.5 dB at 10 kHz current measurement, and maximum change of the amplitude response of 0.0335%·°C−1 with thermal compensation.
    [Show full text]
  • High Sensitivity Differential Giant Magnetoresistance (GMR) Based Sensor for Non-Contacting DC/AC Current Measurement
    Article High Sensitivity Differential Giant Magnetoresistance (GMR) Based Sensor for Non-Contacting DC/AC Current Measurement Cristian Mușuroi, Mihai Oproiu, Marius Volmer * and Ioana Firastrau 1 Department of Electrical Engineering and Applied Physics, Transilvania University of Brasov, 29 Blvd. Eroilor, 500036 Brasov, Romania; [email protected] (C.M.); [email protected] (M.O.); [email protected] (I.F.) * Correspondence: [email protected] Received: 10 December 2019; Accepted: 3 January 2020; Published: 6 January 2020 Abstract: This paper presents the design and implementation of a high sensitivity giant magnetoresistance (GMR) based current sensor with a broad range of applications. The novelty of our approach consists in using a double differential measurement system, based on commercial GMR sensors, with an adjustable biasing system used to linearize the field response of the system. The work aims to act as a fully-operational proof of concept application, with an emphasis on the mode of operation and methods to improve the sensitivity and linearity of the measurement system. The implemented system has a broad current measurement range from as low as 75 mA in DC and 150 mA in AC up to 4 A by using a single setup. The sensor system is also very low power, consuming only 6.4 mW. Due to the way the sensors are polarized and positioned above the U- shaped conductive band through which the current to be measured is flowing, the differential setup offers a sensitivity of about between 0.0272 to 0.0307 V/A (signal from sensors with no amplifications), a high immunity to external magnetic fields, low hysteresis effects of 40 mA, and a temperature drift of the offset of about −2.59×10−4 A/°C.
    [Show full text]
  • Simplifying Current Sensing (Rev. A)
    Simplifying Current Sensing How to design with current sense amplifiers Table of contents Introduction . 3 Chapter 4: Integrating the current-sensing signal chain Chapter 1: Current-sensing overview Integrating the current-sensing signal path . 40 Integrating the current-sense resistor . 42 How integrated-resistor current sensors simplify Integrated, current-sensing PCB designs . 4 analog-to-digital converter . 45 Shunt-based current-sensing solutions for BMS Enabling Precision Current Sensing Designs with applications in HEVs and EVs . 6 Non-Ratiometric Magnetic Current Sensors . 48 Common uses for multichannel current monitoring . 9 Power and energy monitoring with digital Chapter 5: Wide VIN and isolated current sensors . 11 current measurement 12-V Battery Monitoring in an Automotive Module . 14 Simplifying voltage and current measurements in Interfacing a differential-output (isolated) amplifier battery test equipment . 17 to a single-ended-input ADC . 50 Extending beyond the maximum common-mode range of discrete current-sense amplifiers . 52 Chapter 2: Out-of-range current measurements Low-Drift, Precision, In-Line Isolated Magnetic Motor Current Measurements . 55 Measuring current to detect out-of-range conditions . 20 Monitoring current for multiple out-of-range Authors: conditions . 22 Scott Hill, Dennis Hudgins, Arjun Prakash, Greg Hupp, High-side motor current monitoring for overcurrent protection . 25 Scott Vestal, Alex Smith, Leaphar Castro, Kevin Zhang, Maka Luo, Raphael Puzio, Kurt Eckles, Guang Zhou, Chapter 3: Current sensing in Stephen Loveless, Peter Iliya switching systems Low-drift, precision, in-line motor current measurements with enhanced PWM rejection . 28 High-side drive, high-side solenoid monitor with PWM rejection . 30 Current-mode control in switching power supplies .
    [Show full text]
  • Measurement of Electric Current Using Optical Fibers: a Review
    Jan NEDOMA, Marcel FAJKUS, Radek MARTINEK VSB - Technical university of Ostrava doi:10.15199/48.2017.11.30 Measurement of electric current using optical fibers: A Review Abstract. This article deals with the measurement of electric current in the energy via optical fibers. Nowadays, the measurement of the electrical current by using optical fiber most commonly based on the principle of Faraday effects, thus the magneto-optic effect. FOCS (Fiber-Optic Current Sensor) is very accurate, modular and easy to install. Another advantage is the isolation of the measuring part from the primary technology, which is sensed. Optical fibers can also be used to measure the inside of the transformer. It also offers the possibility of measuring the temperature of winding. The main contribution of the paper is to summarize interesting published results to date, approaches and basic principles leading to the analysis and to defining the electrical values such as electrical current using fiber optic technology. Streszczenie. W artykule opisano możliwości pomiaru prądu przy wykorzystaniu światłowodów. Czujnik FOCS (fiber optic current sensor) jest dokładny I łatwy do instalacji. Inną zaletą jest oddzielenie galwaniczne od toru prądowego. W artkule przedstawiono przegląd prac na ten temat, przegląd rozwiązań konstrukcyjnych I zastosowań oraz analizę właściwości metody. Pomiar pradu elektrycznego przy wykorzystaniu światłowodów. Keywords: fiber-optic technology, electrical current, current sensor, magneto-optic effect. Słowa kluczowe: światłowody, pomiar prądu, zjawisko Faradaya. Introduction analogue and digital outputs, easy to install, adaptable The fiber-optic sensor is based on the use of Faraday's shape of sensing head, small size and weight, no magnetic magneto-optical effect (year of discovery is 1845), in which centering necessary, no magnetic overload problem, there is a magnetic rotation of plain of the polarized light, immunity to electromagnetic interference and many others.
    [Show full text]
  • Integrated Electric Vehicle Shunt Current Sensing System for Concurrent Revenue Metering and Detection of DC Injection †
    energies Article Integrated Electric Vehicle Shunt Current Sensing System for Concurrent Revenue Metering and Detection of DC Injection † Olga Mironenko 1,* , Garrett Ejzak 1 and Willett Kempton 1,2 1 Department of Electrical and Computer Engineering, University of Delaware, Newark, DE 19716, USA; [email protected] (G.E.); [email protected] (W.K.) 2 College of Earth, Ocean and Environment, University of Delaware, Newark, DE 19716, USA * Correspondence: [email protected] † The manuscript is based upon the first author’s Ph.D. thesis, chapter 3. Abstract: Certified electric vehicle power converters can inject DC current into the AC grid if they fail. Verification of DC injection by electric vehicle supply equipment can be a cost-effective extra measure to ensure power quality from a variety of plugged-in electric vehicles. As electric vehicle supply equipment typically performs high-accuracy revenue energy metering, we propose that measurement of AC current and DC injection with a single sensor is the most economically efficient design. This article presents an integrated shunt current sensing system with separation of AC and DC signals for concurrent revenue metering and DC injection detection. It also shows how the combined sensor is integrated into 19.2 kW single-phase electric vehicle supply equipment, and outlines how the design would be extended to 100 kW three-phase electric vehicle supply equipment. The prototype can detect DC injection of ≥400 mA in an AC current up to 80 A in accordance with the IEEE 1547-2018 standard. The prototype can also conduct revenue metering within the 1.0 accuracy class.
    [Show full text]
  • ACS712 Current Sensor
    ACS712 Fully Integrated, Hall Effect-Based Linear Current Sensor with 2.1 kVRMS Voltage Isolation and a Low-Resistance Current Conductor Features and Benefits Description ▪ Low-noise analog signal path The Allegro® ACS712 provides economical and precise ▪ Device bandwidth is set via the new FILTER pin solutions for AC or DC current sensing in industrial, ▪ 5 μs output rise time in response to step input current commercial, and communications systems. The device ▪ 80 kHz bandwidth package allows for easy implementation by the customer. ▪ Total output error 1.5% at T = 25°C A Typical applications include motor control, load detection and ▪ Small footprint, low-profile SOIC8 package ▪ 1.2 mΩ internal conductor resistance management, switched-mode power supplies, and overcurrent fault protection. ▪ 2.1 kVRMS minimum isolation voltage from pins 1-4 to pins 5-8 ▪ 5.0 V, single supply operation The device consists of a precise, low-offset, linear Hall ▪ 66 to 185 mV/A output sensitivity sensor circuit with a copper conduction path located near the ▪ Output voltage proportional to AC or DC currents ▪ Factory-trimmed for accuracy surface of the die. Applied current flowing through this copper ▪ Extremely stable output offset voltage conduction path generates a magnetic field which is sensed ▪ Nearly zero magnetic hysteresis by the integrated Hall IC and converted into a proportional ▪ Ratiometric output from supply voltage voltage. Device accuracy is optimized through the close TÜV America proximity of the magnetic signal to the Hall transducer. A Certificate Number: precise, proportional voltage is provided by the low-offset, U8V 06 05 54214 010 chopper-stabilized BiCMOS Hall IC, which is programmed for accuracy after packaging.
    [Show full text]
  • Using Current Sense Resistors for Accurate Current Measurement
    APPLICATION NOTE Using Current Sense Resistors for Accurate Current Measurement INTRODUCTION Global trends such as the demand for lower CO2 emissions, the smartening of the electricity supply grid and the electrification of our automobiles are all driving the need for electronic circuits to become more efficient. For circuit designers and systems operators, understanding what level of current is flowing through a circuit and being delivered to a load can be very helpful. Maximizing the operating performance of a battery, controlling motor speeds, and the ability to hot swap server CSS Series units are examples of applications that can all benefit from the use of accurate current measurement. Current Sense Resistors This application note will present why current sense resistors are optimal, low-cost solutions that help OEMs create more efficient circuit designs in a wide range of applications. HOW CURRENT SENSE RESISTORS WORK Current sense resistors are recognized as cost-effective components that help improve system efficiency and reduce losses due to their high measurement accuracy compared to other technologies. CSM Series While they are ideal for applications in virtually all market segments, current sense resistors are Current Sense Resistors particularly useful in helping developers precisely measure current in their automotive, industrial and computer electronics designs. Current sense resistors work by detecting and converting current to voltage. These devices feature very low resistance values, and therefore, cause only an insignificant voltage drop of 10 to 130 mV in the application. A shunt resistor is placed in series with the electrical load whereby all the current to be measured will flow through it.
    [Show full text]
  • Application Note Current Sensing Using Linear Hall Sensors
    February 2009 Current Sensing Using Linear Hall Sensors Application Note Rev. 1.1 Sense & Control Edition 2009-02-03 Published by Infineon Technologies AG 81726 Munich, Germany © 2009 Infineon Technologies AG All Rights Reserved. Legal Disclaimer The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics. With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, Infineon Technologies hereby disclaims any and all warranties and liabilities of any kind, including without limitation, warranties of non-infringement of intellectual property rights of any third party. Information For further information on technology, delivery terms and conditions and prices, please contact the nearest Infineon Technologies Office (www.infineon.com). Warnings Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body or to support and/or maintain and sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may be endangered. Current Sensing Current Sensing Using Linear Hall Sensors Revision History: 2009-02-03, Rev.
    [Show full text]
  • Non-Intrusive Current-Sensing Using TMR: a Comparison Between TMR Sensors, Sense Resistors, Hall-Effect Sensors and Current Transformers
    Non-Intrusive Current-Sensing Using TMR: A Comparison Between TMR Sensors, Sense Resistors, Hall-effect Sensors and Current Transformers Referenced Device Crocus Technology’s advancements in TMR technology, semiconductor integration on standard CT100 wafers and advances nodes allows it to fulfill the ever-increasing demand for small, reliable and cost- Abstract effective magnetic sensors: including, magnetic As the demand for current sensing continues to latches, angle sensors, speeds and direction increase and the applications become diverse, the sensors. need for a universal, accurate and cost-effective At its core, a TMR sensor’s resistance ‘R’ will change current sensor is clear. Circuit designers have under a changing external magnetic field ‘H’. This is different options for current measurement, these referred to as the R(H) curve. The response of the options differ in the underlying technology of the TMR sensor (meaning it’s R(H) curve) can be sensor, they also differ in the design and adjusted depending on the end application. recommended implementation of the manufacturer. Hysteresis, Saturation fields, sensitivity are It can be daunting, or at least resource consuming, examples of the parameters that can be set to decide the best current sensor that fits the design differently for different products. constraints in terms of: accuracy, isolation and The TMR sensor implemented in the CT100 device overall safety both of the circuit and the user, power has a ratiometric linear output. It is optimized to have consumption and power loss (heat dissipation), etc. zero-hysteresis, saturation fields at ±20 mT and a As a well-established technology, TMR (Tunnel linearity error of less than ±1% over the operating Magneto-Resistance) offers a set of features that range.
    [Show full text]