Rebel® Rooftop for Retail

Total Page:16

File Type:pdf, Size:1020Kb

Rebel® Rooftop for Retail Rebel® commercial packaged rooftop systems for retailers Advanced technologies propel energy savings and customer comfort to uncommon levels. 3 – 28 tons Capitalize on superior energy savings Designed for efficiency A Rebel packaged rooftop system is the ideal solution for any retail The graph below shows a 12-ton Rebel single-zone VAV gas heat unit application. Rebel comes equipped with an array of energy-saving features versus a CAV gas heat unit set in a 7-day retail application in climates like ECM fans, inverter scroll compressors, and the energy recovery wheel. where annual energy costs often exceed $5,000 (results vary depending Producing an astounding 43 percent part-load energy savings above on location). ASHRAE’s 90.1-2016 energy standard code minimums, Rebel generates It’s easy to see Rebel saves...and saves significantly. Rebel gives retailers efficiencies previously unachievable in a commercial rooftop system. one of the lowest total costs of ownership for any commercial rooftop Exceptional cost savings and performance makes Rebel ideal for any retail system. Call your Daikin representative to model your potential savings application such as 100 percent outdoor air, variable air volume (VAV) with using our enhanced Rebel Payback Calculator. duct pressure control, single-zone VAV, or constant air volume (CAV). Rebel annual energy cost savings 60% 50% 40% 30% 20% 10% 0% Fairbanks Minneapolis Denver Albuquerque Chicago Las Vegas Atlanta Houston Miami Baltimore Inverter scroll compressor boosts efficiency At the core of Rebel’s remarkable performance is its inverter scroll Rebel’s inverter compressor, on the other hand, is tightly modulated to compressor, which produces superior energy efficiencies, an extended provide optimal efficiency and consistently maintain user-established lifecycle, ultra-quiet operation, and better shopper comfort. setpoints at both full and part-load conditions. Consequently, the system’s operation consumes only the energy required to meet the Non-inverter compressors must operate at full capacity, even in mild cooling needs of the space. conditions. Like a light switch, these units must be either turned on or turned off. At part-load conditions, they cycle frequently between on For retailers, these extraordinary part-load capabilities mean exceptional and off, leading to spikes in power demand as well as compressor wear, energy savings, precise comfort control, and accelerated payback. temperature fluctuations, and overcooling. Effective dehumidification for comfortable shopping Packaged rooftop systems can deliver effective dehumidification only when their compressors are actively working. As a result, the on/off cycling of non-inverter compressors reduces dehumidification capacity. In contrast, Rebel’s inverter compressor modulates, providing steady moisture regulation for the in-store environment. Rebel is well-equipped to provide you with the dehumidification your store needs. It offers two-point temperature control, which utilizes cooling coils and modulating hot gas reheat coils to perform effective dehumidification without overcooling the air. 11 6 5 4 43% 6 3 Energy 2 1 Savings 10 1] Variable speed inverter scroll compressor 5] Electronic expansion valves - Optimum comfort via modulating capacity control - Delivers optimum control of and discharge air temperature control superheat 5 - Exceptional part-load efficiencies - Prevents liquid refrigerant - Enclosed for quiet operation compressor slugging 2 - Increases efficiencies by lowering 1 head pressure 2] Variable speed heat pump - More economical than gas heat during cold weather 6] Seamless top panel and hinged - Greater comfort control from access door variable speed capacity - Leak-free construction - Easy service and maintenance access using 1/4-turn latch doors 3] Direct-drive variable speed ECM or VFD fan motors - Increases system reliability and 7] Energy recovery wheel efficiency by eliminating belts 3 - Reduces summer/winter and bearing setscrews ventilation loads by transferring - Increases energy savings at part- energy to and from exhaust air. load conditions - Increases efficiency by up to 7 - Offers superior fan efficiencies 20 percent and quiet performance - Simplifies operation with integrated unit control 4] MicroTech® III unit controller - Wheel is an integral part of the cabinet, eliminating field - Simplified BAS integration using assembly and water leakage Open Choices™ feature with BACnet® or LONMARK® communications 8] 2” and 4” slide-out filter racks - Improved serviceability with intuitive unit diagnostics - Quick serviceability with easy filter change-outs - Option of DIII gateway or iTM with BACnet Client - MERV 8 prefilters, MERV 11 – 14 after-filters for iTouch VRV controls - 4” factory-installed filters (16 – 28 tons) 9] Supplemental heat 15] Outdoor air monitor - Gas furnace with up to 12:1 9 - Building pressure override automatically opens dampers turn-down - Monitor ensures precision airflow - Electric heat with SCR - Efficient integrated operation with mechanical cooling - Hot water heat 10] Double-wall foam cabinet 15 - Provides for fiber-free air stream - Energy-efficient R7 and R13 foam-injected panels 11 11] Condenser fans with variable Rooftop efficiencies speed ECM motor Many stores often require only a portion of their rooftop unit’s - Energy savings cooling power. One analysis of the cooling load of a retail building - Quiet operation in St. Louis, Missouri showed the majority of the cooling demand - Fully modulating head happening at 40 percent of full-load capacity or lower. pressure control St. Louis store yearly runtime at part-load conditions 700 12] Modulating hot gas reheat coil 12 600 - Reuses waste heat for increased energy efficiency 500 - Maintains desired indoor dew 400 point temperatures 300 - Two-point temperature control provides effective 200 Cooling Runtime (hours) Runtime Cooling dehumidification without 100 overcooling the space 0 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 Cooling Load (percentage) 13] Stainless steel, double-slope drain pan Rebel excels under partial-load conditions, offering up to 70 - Prevents corrosion and percent improvements to IEER compared to ASHRAE 90.1-2016 standing water to promote code minimums, which equates to 43 percent energy savings. higher indoor air quality With EERs that surpass 90.1-2016 minimums by up to 14 percent, 13 Rebel is also equipped to provide efficient full-load operation. 14] Economizer Between its part and full-load efficiencies, Rebel is one of the - Free cooling when outdoor industry’s most energy-efficient rooftop systems, providing energy conditions are favorable savings and often earning utility rebates. - Meets many local statutes for fresh air provision Efficiency ratios (10-ton unit) - Integrates operation 22 with mechanical cooling 20 - Increases efficiency with 14 IEER demand control ventilation 18 EER 16 14 8 12 Up to 70% Better 14% 10 Better ASHRAE RTU RTU Daikin 90.1-2016 digital scroll multiple steps Rebel RTU Advanced technology drives customer comfort Elevate the shopping experience As a retailer, you may feel conflicted between the need to ensure shopper Get connected ® comfort and the desire to keep energy costs low. With Rebel packaged Smart businesses run on Intelligent Equipment rooftop unit, you get both. Gain the freedom and control to monitor and manage your HVAC Rebel delivers powerful temperature control and quiet operation to equipment effectively create a pleasant environment for your customers. The inverter scroll Intelligent Equipment is a control solution that connects directly with compressor enables precision temperature control by moderating speed at your Rebel commercial packaged rooftop unit to monitor energy part-load conditions. This feature also decreases radiated noise, as do the consumption at the equipment level for deeper, more accurate ECM condenser fans, so Rebel stays quiet while keeping your customers performance measurement. comfortable. For less than it costs to run your smart phone, Intelligent Equipment In addition, Rebel’s economizer can be set to monitor and adjust outdoor provides real-time, direct access to 150 data points on a Rebel unit. air intake to meet air quality requirements. Do more than ever before with: Providing high-quality indoor air, quiet performance, and precise - Remote access temperature control, Rebel ensures that your building is a relaxing space - Performance data for customers to explore and shop. - Energy monitoring and management - Unit diagnostics High-tech features lead to lifecycle savings No other solution gives you the freedom and control to monitor and Rebel achieves one of the lowest costs of ownership among comparable manage your equipment as deeply, freely, accurately, and efficiently. units because its efficient technologies, intelligent controls, and hassle-free maintenance produce energy savings and reliable performance throughout its lifecycle. In addition to precision temperature control, the inverter scroll compressor minimizes cycling, saving energy and extending the unit’s service life. Slide- out features and easy access to electrical and mechanical components make Rebel’s upkeep incredibly simple. Intelligent Equipment’s proactive monitoring and timely notifications for maintenance keep Rebel performing year after year, so you get long-term uninterrupted operation. Take control over your space and give your customers an incredibly comfortable shopping experience, all while enjoying the benefits of Rebel’s
Recommended publications
  • D-PAC Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency
    Digital Precise Air Control System D-PAC Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency AAON • 2425 South Yukon Avenue • Tulsa, Oklahoma 74107 • (918) 583-2266 • Fax (918) 583-6094 • www.aaon.com Total Control Indoor Air Quality and Comfort ndoor air quality (IAQ) and occupant comfort are two of the most Scroll compressor, return important factors to consider with any HVAC system design. One air bypass, and modulating ofI the leading causes of poor IAQ and occupant discomfort is too hot gas reheat for energy much moisture in the air, commonly referred to as high humidity. efficient load matching IAQ problems associated with high humidity include mold growth, humidity control. An AAON condensation and increased sickness and allergic reactions. As for D-PAC controller is also occupant comfort, the saying goes “It’s not the heat, it’s the humidity”. factory installed to provide Improving indoor air quality and occupant comfort by controlling optimum performance of the the humidity and the temperature will help with these problems, system. Thus, the D-PAC boost productivity, and even improve the general well-being of the system provides an energy occupants. efficient, cost effective solution for temperature One way to improve IAQ and occupant comfort is with uniform and humidity control. humidity and temperature control. Ideally indoor conditions should remain consistently around 75°F dry bulb and 45% relative humidity. This will keep the occupants comfortable and decrease the likelihood The Competition of IAQ issues. ome in the HVAC industry assume that as Energy Use theS dry bulb temperature ontrolling both temperature and humidity can be very energy is being controlled the intensive.
    [Show full text]
  • Scroll Compressor Modelling for Heat Pumps Using Hydrocarbons As Refrigerants Paul Byrne, Redouane Ghoubali, Jacques Miriel
    Scroll compressor modelling for heat pumps using hydrocarbons as refrigerants Paul Byrne, Redouane Ghoubali, Jacques Miriel To cite this version: Paul Byrne, Redouane Ghoubali, Jacques Miriel. Scroll compressor modelling for heat pumps using hydrocarbons as refrigerants. International Journal of Refrigeration, Elsevier, 2013, 41, pp.1-13. 10.1016/j.ijrefrig.2013.06.003. hal-00926697 HAL Id: hal-00926697 https://hal.archives-ouvertes.fr/hal-00926697 Submitted on 10 Jan 2014 HAL is a multi-disciplinary open access L’archive ouverte pluridisciplinaire HAL, est archive for the deposit and dissemination of sci- destinée au dépôt et à la diffusion de documents entific research documents, whether they are pub- scientifiques de niveau recherche, publiés ou non, lished or not. The documents may come from émanant des établissements d’enseignement et de teaching and research institutions in France or recherche français ou étrangers, des laboratoires abroad, or from public or private research centers. publics ou privés. Scroll compressor modelling for heat pumps using hydrocarbons as refrigerants Paul BYRNE*, Redouane GHOUBALI, Jacques MIRIEL Université Européenne de Bretagne Université de Rennes1, Laboratoire LGCGM, Equipe MTRhéo IUT Génie Civil, 3 rue du Clos Courtel, BP 90422, 35704 Rennes Cedex 7, France Phone: +33 2 23 23 42 97 - Fax: +33 2 23 23 40 51 * corresponding author: [email protected] ABSTRACT Hydrocarbons are today considered as promising alternatives to hydrofluorocarbons thanks to their low environmental impact and their easy implementation. However, some precautions have to be taken to thwart their flammability. European regulations impose to take stringent measures regarding components and to install heat pumps in unoccupied spaces.
    [Show full text]
  • With Air Purification
    As clean as it is Cool with Air Purification Do you know how small the size of Ultrafine dust which impact your helath? Traps all particles without fail, even Ultrafine dust (PM 1.0) Micro Dust Filter 90㎛ 50 ~ 70㎛ PM 10 PM 2.5 PM 1.0 Fine Human Hair Dust, Pollen, Combustion Smog, Smoke, Beach Sand Mold, etc particles, organic Diesel soot compounds, metals, etc. ※ PM : Particulate matter is the sum of all solid and liquid particles suspended in air many of which are hazardous. This complex mixture includes both organic and inorganic particles, such as dust, pollen, soot, smoke, and liquid droplets. Protect your family from Ultrafine dust. www. LG.COM As clean as it is Cool with Air Purification Why your A/C needs air purification? Outdoor air is bad? No need to worry. With the LG ThinQ app, you can monitor the state of the indoor air at a glance. Traps all particles without fail, even Ultrafine dust (PM 1.0) 90㎛ 50 ~ 70㎛ PM 10 PM 2.5 PM 1.0 Fine Human Hair Dust, Pollen, Combustion Smog, Smoke, Beach Sand Mold, etc particles, organic Diesel soot compounds, metals, etc. www. LG.COM DUALCOOL with Air Purification KEY FEATURES Air Conditioner and air purifier in one PM1.0 sensor is automatically activated and filtration system removes microscopic dust after 5 million lons capture them. Step 1 PM 1.0 Auto Sensing Step 2 Ion Diffuser Step 3 Filtration System Step 4 Display - Indoor Air Detecting indoor dust 5 million negative ions emitted Effective particle capture.
    [Show full text]
  • Fluid Mechanical Modelling of the Scroll Compressor
    View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by Mathematical Institute Eprints Archive Fluid mechanical modelling of the scroll compressor by Peter Howell University of Oxford Mathematical Institute, 24{29 St Giles', Oxford OX1 3LB, UK Preface. This case-study concerns the flow of gas in a so-called Scroll Compressor. In this device a number of chambers of gas at different temperatures and pressures are separated by narrow channels through which leakage can occur. Using compressible lubrication theory, an estimate for the leakage rate is found in terms of the material properties of the gas and the geometry of the compressor. Thus a simple functional is obtained which allows the efficiency of different compressor designs to be compared. Next we derive a set of ordinary differential equations for the temperature and pressure in each chamber; the coupling between them arises from the leakage. The numerical solution of these equations allows a realistic simulation of a working compressor, and suggests some interesting possibilities for future designs. This problem arose at the 32nd European Study Group with Industry held in September 1998 at the Technical University of Denmark | the first ever to be held outside the United Kingdom. It was presented by Stig Helmer Jørgensen from DANFOSS, which is Denmark's largest industrial group and specialises in controls for refrigeration and heating. The Danish Study Group was a great success and is expected to be repeated annually henceforth. The feedback from DANFOSS has also been encouraging and hopefully this represents the start of a long-term collaboration.
    [Show full text]
  • Small Air to Water Heat Pump Chiller | Resdiential Hydronic Heat Pump
    The World’s Most Efficient Chiller Heat Pump Ultra-Efficient Multiple IDUs - Up to 8 Indoor Units Per CX34 CX34 Air-To-Water Heat Pump 2 Tons Cooling / 3 Tons heating IPLV Cooling 26,615 BTU COP 6.75 EER 23.02 Heating 33,813 BTU COP 3.92 Save More w/ DC Inverter Fan Motors All of the thin-line (5.1" thin) wall, floor and ceiling fan coil units use high efficiency and nearly silent DC Inverter fan motors, designed for 115v 50/60Hz power. 220v 50/60Hz standard FCUs are available for export customers. Geothermal Performance There is no Energy Star program for air to water heat pumps. However, the Chiltrix air-cooled chiller exceeds the Energy Star EER requirements for geothermal water-to-water systems. Server Room Cooling Ultra High Efficiency Heat Pump Chiller Chiltrix offers an optional Free Cooling add-on which allows up The CX34 obtains its ultra high efficiency using existing technologies in to EER 141+ & COP 41+ cooling performance during winter at a new way. For example, we use a DC Inverter compressor and a DC low ambient temperatures. Chiltrix chillers are also available Inverter water pump (both are variable speed) controlled together with in a N+1 redundant configuration. a DC inverter fan motor to achieve the best possible balance of water flow rate, compressor speed, and energy use. Solar Ready Perfect for solar PV operation with super low power draw and A special control algorithm looks at the temperature delta between the a 2 amp soft start that’s easy on inverters and batteries.
    [Show full text]
  • Scroll Compressors
    SCROLL COMPRESSORS SF 1-6 (1.5-5.5 kW/2-7.5 hp) / SF+ 2-22 (2.2-22 kW/3-30 hp) PURE OIL-FREE AIR As there is no metal-to-metal contact between the compression scrolls, there is no need for oil lubrication in the compression chamber. Therefore, the scroll compression principle guarantees high-quality, oil-free air. As a result, the SF compressor is oil-free in every way. ENERGY EFFICIENCY COST-EFFICIENT, The SF scroll compressors, standard equipped with IE3 Premium efficiency motors, are suited for sensitive applications HIGH-QUALITY AIR which require flexibility and energy efficiency. Unloaded power consumption is eliminated thanks to the simple start/stop With its state-of-the-art oil-free compressor control. Advanced scroll technology guarantees an optimal technologies such as screw, tooth, centrifugal, free air delivery and low duty cycle applications. reciprocating and scroll, Atlas Copco provides the right solutions for your specific needs. EXTREMELY LOW NOISE LEVEL As oil-free compressed air is a prerequisite for The slow speed of the scroll compression elements ensures that many manufacturing processes, we ensure the SF scroll compressors are extremely quiet. Sound levels are consistent oil-free air by preventing oil from as low as 53 dB(a), making the SF the perfect choice for your sensitive working environment. entering your compressed air system. SIMPLICITY AND RELIABILITY + The SF and SF ranges of oil-free scroll The SF scroll compressors stand for simplicity and reliability. air compressors unite Atlas Copco’s vast The compressor has a minimal number of moving parts, experience and knowledge in a class-leading ensuring a long operating life with limited service interventions.
    [Show full text]
  • Copeland-Scroll-Compressor-Large-Zx
    Copeland Scroll™ Compressor Large ZX Condensing Unit & EMP Rack for Refrigeration Applications User Manual Copeland Scroll™ Large ZX Condensing Unit and EMP Rack Emerson is pleased to offer Copeland Scroll Large ZX Condensing Unit and EMP Rack for Refrigeration Applications. In addition to 2-9 HP condensing unit, Emerson expands Next Generation ZX platform to 12-20 HP medium temperature and low temperature condensing unit and rack, configuring with digital modulation for best in class energy efficiency and food safety. Emerson ZX series has been highly successful in global market and enjoys proven success with its energy savings and customer-friendly electronic features. Table of contents Overview 4 Nomenclature 7 Bill of material 8 Envelope 9 Technical data 11 Physical layout 13 CoreSense™ controller 17 Network wiring 26 Installation 29 Electrical connection 29 Refrigeration piping installation 29 Location and fixing 32 Start up and operation 35 Vacuuming 35 Charging procedure 35 Check before starting & during operation 37 Alarm codes 39 Troubleshooting 41 Temperature sensor resistance table 48 Wiring diagrams 49 Contact lists 52 Overview Disclaimer Thanks for purchasing Copeland Scroll™ Large ZX Condensing Unit and EMP Rack from Emerson. Large ZX Condensing Unit and EMP Rack exhibit market-leading quality in terms of cooling capacity and operating range, as part of product extension for Next Generation ZX platform in larger capacity range and installation variants. The product is designed to operate reliably and to deliver high operating efficiencies in medium and low temperature refrigeration applications. It also provides constant monitoring of the compressor operating conditions and displays the running or fault conditions of the condensing unit or rack.
    [Show full text]
  • Inverter High Wall Unit
    Indoor Unit HEAT PUMP Unit 42QHA012VS 42QHA018VS 42QHA024VS 42QHA030VS Unit Size TR 1.0 1.5 2.0 2.5 Inverter High Wall Unit BTU/h 12000 18,000 22,000 27000 Rated Capacity at T1 Cooling kW 3.51 5.25 6.45 7.90 42QHA/38QHA BTU/h 10600 16,400 19,200 23,200 Rated Capacity at T3 Cooling kW 3.09 4.80 5.61 6.80 Rated Capacity Heating Watts 3,500 5,450 7,600 8,300 Power Supply V-Ph-Hz 220-240V- 50/60Hz, 1Ph Total System Power Input at T1 Cooling Watts 870 1,300 1,570 2160 Total System Power Input at T3 Cooling Watts 1,080 1,630 1,970 2605 Total System Power Input Heating Watts 950 1,390 2,100 2100 EER at T1 Cooling Btu/W-h 13.75 13.85 14.00 12.50 EER at T3 Cooling Btu/W-h 9.80 10.05 9.75 8.85 COP Heating w/w 3.65 3.90 3.60 3.95 Air Filter Type Washable air filter Air Flow Rate (High/ Medium/ Low Speed) CFM 356 / 280 / 230 685 / 535 / 485 685 / 540 / 485 765 / 645 / 575 Indoor Noise Level (High/ Medium/ Low Speed) dBA 41 / 37 / 33 49 / 43 / 41 49 / 45 / 41 51 / 48 / 45 Net / Gross Weight Kg 8.7 / 11.1 13.5 / 17.1 13.8 / 17.4 20 / 25.9 Dimensions (W x D x H) mm 802 x 189 x 297 1080 x 226 x 335 1080 x 226 x 335 1259 x282 x362 Liquid inch 1/4" 3/8" Pipe Connection Size Suction inch 1/2" 5/8" Drain inch 5/8" HEAT PUMP Outdoor Unit Unit 38QHA012VS 38QHA018VS 38QHA024VS 38QHA030VS Power Supply V-Ph-Hz 220-240V- 50/60Hz, 1Ph Compressor Type DC Inverter Rotary Refrigerant R410a Vertical + mts 25 30 30 50 Horizontal Refrigerant Pipe (Max Length) Vertical mts (OU & IU) 10 20 20 25 Recommended Wire Size/No.
    [Show full text]
  • Exergy Analysis and Thermodynamic Model for Reciprocating and Scroll Compressors Used in an Air Conditioning Packaged Unit
    Journal of Engineering and Development, Vol. 18, No.5, September 2014, ISSN 1813- 7822 Exergy Analysis and Thermodynamic Model for Reciprocating and Scroll Compressors Used in an Air Conditioning Packaged Unit Prof. Dr. Sabah Tarik Ahmad Prof. Dr. Wahid S. Mohammad Lecturer. Dr. Louay Abd-Alazez Mahdi Machine and Equipment department., University of Technology Abstract : An exergical thermodynamic model was used to analyze and optimize reciprocating and scroll compressors of an air condition packaged unit. The experimental work was carried out using 3.0 TR packaged unit manufactured by Carrier Company. The experimental and the analysis show that the exergy dissipative due to friction losses in bearings, suction and discharge valves and the transformation of power are larger than the heat losses. The exergy efficiency for the compressor was varying between (60-68) %. The scroll compressor was found to be better than the reciprocating compressor at an environmental temperature of 35℃ due to its low total losses which is 10% less than the reciprocating compressor ones . The heat losses percentages were 3% for scroll and 2% for the reciprocating of the total power input. The thermodynamic model has shown to be reliable in dealing with a change in the environmental temperatures and such system components and size. Keywords: Exergy analysis, thermodynamic model, reciprocating compressor, scroll compressor. ﺗﺣﻠﯾل ﻟﻠطﺎﻗﺔ اﻟﻣﺗﺎﺣﺔ ﻣﻊ ﻧﻣوذج ﺛرﻣودﯾﻧﺎﻣﯾﻛﻲ ﻟﻠﺿواﻏط اﻟﺗرددﯾﺔ و اﻻورﺑﯾﺗﺎﻟﯾﺔ ﻓﻲ وﺣدة ﺗﻛﯾﯾف ﻣﺟﻣﻌﮫ ا.د. ﺻﺒﺎح طﺎرق اﺣﻤﺪ ا.د. وﺣﯿﺪ ﺷﺎﺗﻲ ﻣﺤﻤﺪ م.د. ﻟﺆي ﻋﺒﺪ اﻟﻌﺰﯾﺰ ﻣﮭﺪي ﻗﺴﻢ ھﻨﺪﺳﺔ اﻟﻤﻜﺎﺋﻦ واﻟﻤﻌﺪات / اﻟﺠﺎﻣﻌﺔ اﻟﺘﻜﻨﻮﻟﻮﺟﯿﺔ اﻟﺧﻼﺻﺔ : ﺗﻢ اﺳﺘﺨﺪام ﻣﻮدﯾﻞ دﯾﻨﺎﻣﯿﻜﻲ ﺣﺮاري ﺑﺎﺳﺘﺨﺪام ﻣﺒﺪأ اﻟﻄﺎﻗﺔ اﻟﻤﺘﺎﺣﮫ (Exergy ) ﻟﺘﺤﻠﯿﻞ وﺗﺤﺪﯾﺪ أداء ﻧﻮﻋﯿﻦ ﻣﻦ اﻟﻀﻮاﻏﻂ اﻷول ﺗﺮددي واﻷﺧﺮ اورﺑﯿﺘﺎﻟﻲ ،ﻣﺜﺒﺘﯿﻦ ﻓﻲ ﺟﮭﺎز ﺗﻜﯿﯿﻒ ﺳﻌﺔ 3طﻦ ﺗﺒﺮﯾﺪ ﻣﺼﻨﻊ ﻣﻦ ﻗﺒﻞ ﺷﺮﻛﺔ Carrier .
    [Show full text]
  • Inverter Scroll Compressor Advantages
    For Internal Training Inverter scroll compressor advantages Sales / Technical Guide Compressor Mechanism (Inverter and Digital comp.) Inverter Scroll Digital Scroll The Mechanism of Inverter Scroll The Mechanism of Digital Scroll Discharge gas PWM valve Radial compliant Discharge Fixed scroll mechanism Bleed hole Orbiting scroll Fixed scroll (spring loaded) Suction Crank shaft Pivot Bearing mechanism Orbiting scroll Mitsubishi Electric inverter scroll compressor adopts radial Digital scroll compressor adopts refrigerant bypass mecha- compliant mechanism which contributes high efficiency nism to control its capacity. Though it can work as inverter even at the low or high speed operation. This mechanism type in terms of operation range, the efficiency goes down has no clearance between orbiting and fixed scroll, which in light load. means excellent refrigerant seal and high COP. 1 Mechanism of Inverter Scroll Mechanism of Digital Scroll Radial compliant mechanism Wrap contact force Fixed Scroll F=Fc-Fr Wrap Fixed Scroll Wrap PWM valve on direction of Wrap Orbiting Scroll contact 100% unloaded Wrap Fc no compression Slider Parts Fg Scroll separates by 1mm Fgr Crank shaft Orbiting Scroll Wrap Fc : Centrifugal force of Scroll Wrap With digital scroll compressor, one of the scroll is lifted up Fg : Compressed gass load 1 to control the capacity with electric valve. In light load time Fgr : Compressed gass load 2 or period, the refrigerant leakage is too big to run efficient- ly. Electric valve is always being used and scroll parts vert- ically hit each other inside the shell. This means less reli- ability and shorter lifespan than inverter type. Mitsubishi Electric inverter compressor makes use of the centrifugal force with scroll rotation very well.
    [Show full text]
  • Rebel® Commercial Packaged Rooftop Systems Heating & Cooling Models DPS 003 – 028 3 to 28 Tons R-410A Refrigerant Energy Recovery Wheel
    Catalog 256-14 Rebel® Commercial Packaged Rooftop Systems Heating & Cooling Models DPS 003 – 028 3 to 28 Tons R-410A Refrigerant Energy Recovery Wheel 3–6 tons 7–15 tons Shown with Energy Recovery 16–28 tons Shown with Energy Recovery Table of Contents Table of Contents Introduction . 3 Application Considerations . 16 Features and Options . 4 Unit Location .......................................16 Cabinet, Casing, and Frame . 6 Service Clearance ...................................16 Compressor . .6 Curb Installation .....................................16 Outdoor Coil .........................................7 Acoustical Considerations ...............................22 Indoor Coil . 7 Ductwork Considerations ................................22 Heat Pump Heating ...................................7 Return Duct ........................................22 Modulating Hot Gas Reheat .............................8 Supply Duct . 22 Supply Fan ..........................................8 Duct High Limit ......................................22 Variable Air Volume Control .............................8 Vibration Isolation....................................22 Exhaust Fan .........................................8 Smoke and Fire Protection...............................23 Filters . 8 Variable Air Volume Application ...........................23 Heating Section ........................................9 Single Zone Variable Air Volume Application .................23 Gas Furnace.........................................9 Fan Operating Range...................................23
    [Show full text]
  • Inverter Compressor Technology
    Maverick® II systems - now with inverter compressor technology Market-leading rooftop efficiency solutions Daikin Applied continues to provide Operate quietly market-leading efficiency solutions Inverter compressors provide superior reduction in by offering inverter compressors in sound levels: rooftop systems that include Rebel™ • Sound levels at part-load operation are very low (3-15 ton), RoofPak™ (16-75 ton), and • Irritating on/off compressor cycling is eliminated now - Maverick II (26-50 ton). Inverter compressors modulate, delivering only Outperform digital scrolls the required energy to satisfy space The energy efficiency of an inverter compressor is conditions, providing for exceptional far superior to that of a digital scroll compressor. temperature/humidity control and lower Digital scroll compressors have specific performance limitations that should not be overlooked when making operating costs. compressor selections: Lower operating costs • Digital scroll compressors always operate at full Inverter compressors will reduce your building’s operation speed and are less efficient at part-load applications costs by saving energy: • To try to match building load, digital scrolls require • Use only the required energy to exactly match more energy to load and unload the compressor in building load while minimizing over-cooling 5-20 second intervals • As digital scrolls load and unload, audible noise • Low speed operation reduces energy consumption; levels fluctuate noticeably soft start reduces energy needed for compressor in-rush power • Minimal compressor cycling saves energy (also eliminates DX coil condensate re-evaporation) Improve operation and comfort control The modulating capacity of an inverter compressor eliminates constant on-off cycling and continually maintains the desired leaving air temperature (LAT), resulting in: • Better dehumidification and comfort control • Extended compressor life via better expansion valve control and minimal cycling ©2014 Daikin Applied.
    [Show full text]