Scroll Compressor COMPRESSOR TECHNOLOGY SCROLL FOR HVAC & LIGHT COMMERCIAL APPLICATIONS COMPRESSOR GLOBAL NETWORK Changwon, Korea · A d d r e s s 76 Seongsan-dong, Changwon City Gyeongnam, 641-713, South Korea · Phone +82-55-269-3868 · Fax +82-55-268-4896 · Website www.lge.com/global/business Tianjin, China · A d d r e s s No. 9 Jin Wei road, Bei Chen Dist, Tianjin, China · Phone +86-22-2690-3251 Atlanta, USA · A d d r e s s 4300 North Point Pkwy Suite #100 Alparetta, GA 300 22 · Phone +1-678-328-6433 Dallas, USA · A d d r e s s 2422 Farmers Branch, Texas 75234, · Phone 1-214-256-7835 For continual product development, LG reserves the right to change specifications without notice. © LG Electronics Inc. Printed in Korea. Oct, 2019 WHY LG COMPRESSOR? TECHNOLOGY LG compressors are a group of high-precision LG Component Solutions Business Unit offers meaningful and unique solutions to meet modern machinery and assembly technologies continuously sustainability standards with environmentally sound and energy-efficient technologies. designed to perform even under the most challenging To continue to deliver the highest level of satisfaction to all our partners, environments. Built with today's leading core we will continue with our technological advancements to supply only the best sustainable components technology, inverter motor and drive for optimized and inverter total solutions optimized for residential and commercial environments. products developed to work around the world's evolving needs. MODEL VARIETY LG offers an extensive product selection of scroll compressors for fixed speed, two stage modulting and variable speed with optimized inverter driver, to fully support your various business needs and applications CUSTOMER SUPPORT Enabling customers for optimal business performance, LG offers technical support to ensure our products are delivered with the differentiated level of quality verifiable through our highly qualified R&D process. QUALITY With worldwide recognition for high product quality and sustainability, LG ensures all products are delivered at full value with production quality and safety checks to ensure full customer satisfaction. 01 GLOBAL SITE GLOBAL & MILESTONES 1990 2000 2016 Rotary Compressor World First Linear Compressor Achieved Accumulated Production for Refrigerator Launch Production over 1 Billion Units 1962 1997 2008 Motor 1st Variable Speed Rotary Achieved Accumulated Production Compressor Production Sales over 100 Million Units 1973 1995 2006 2018 Refrigerator Compressor Scroll Compressor Unitary Scroll Compressor 2 stage Modulating Scroll Production Production Launch to North America Unitary Rotary Launch 1998 2009 Direct Drive Motor High Side for Washing Machine Launch Shell Inverter Scroll Lunch Frankfurt Tianjin Qinhuangdao Dallas Germany USA Atlanta Seoul, Changwon Changwon China Korea Noida Delhi Nanjing Taizhou SALES OFFICE 12 SITE Shunde FACTORY 7 SITE India Linear Korea, China (Taizhou) Rayong Joinville Reciprocating Korea, China (Taizhou), Thailand India (Noida) Rotary Korea, China (Tianjin), Thainland (Rayong) Scroll Korea, China (Tianjin) Casting China (Qinhuangdao) Brazil 02 LG Scroll Compressor 03 CONTENTS Why LG Compressor? 01 Milestones & Global Site 02 LG Scroll Compressor - Product Range 06 - Nomenclature 07 - Specification | Fixed Speed R410A 08 - Specification | Fixed Speed R22 18 - Specification | 2 Stage Modulating R410A 20 - Specification | Variable Speed R410A / R32 22 - Specification | Special Application 24 - Specification | Drive 30 - Wiring Diagram 31 - Mounting 31 - Accessory Parts 31 - Packing & Container Stuffing Quantity 31 04 LG Scroll Compressor 05 Product Range Nomenclature Fixed Speed Capacity [RT, Tonnage] 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 6.0 7.0 8.0 (1RT = 12kBtu/hr=3.5kw) A P A 026 D A A P (Φ139) B (Φ160) R (Φ179) R410A Low Q (Φ147) B (Φ160) R (Φ179) R22 side shell P (Φ139) B (Φ160) R (Φ179) R404A Refrigerant Exterior specification (A-Z) Code Refrigeran Type A R410A LSS 2 Stage Modulating H R407C LSS Capacity [RT, Tonnage] J R410A HSS 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 6.0 7.0 8.0 (1RT = 12kBtu/hr=3.5kw) M R404 LSS Low P (Φ139) B (Φ160) R410A S R22 LSS side shell Compressor size (mm) Motor specification Variable Speed P : Φ139 R : Φ179 (A-Z) Capacity [RT, Tonnage] Q : Φ147 G : Φ224 0 2.0 3.0 4.0 5.0 7.0 8.0 10.0 13.3 16.7 20 (1RT = 12kBtu/hr=3.5kw) B : Φ160 P (Φ139) 20/25 SEER (5 ~ 46kBtu) B (Φ160) Low 20/25 SEER (14 ~ 91kBtu) R410A side shell P (Φ139) Generation code Motor code 27.5 SEER (4 ~ 71kBtu) Q (Φ147) (A-Z) Power source (V) Series Motor 27.5 SEER (11 ~ 140kBtu) Phase(Ф) V HZ Q (Φ147) C 1 115 60 Fixed Speed (12 ~ 128kBtu) G 1 220 60 Fixed Speed High B (Φ147) (17 ~ 181kBtu) H 1 220 50 Fixed Speed R410A side shell Capacity J 1 200 / 220 50 Fixed Speed R (Φ160) K 1 208-230 60 Fixed Speed (24 ~ 256kBtu) (Btu/Hr x 1,000) @ 60Hz P 1 265 50 Fixed Speed Q 1 265 60 Fixed Speed Y 3 330 / 420 50 Fixed Speed U 3 380 60 Fixed Speed D BLDC Inverter BLDC / Distributed M BLDC Inverter BLDC / Distributed 06 LG Scroll Compressor 07 Specification Fixed Speed R410A [1 of 5] Test condition Test condition Cooling capacity Input EER COP Cooling capacity Input EER COP Dimension (mm) Refrigerant Type Frequency Voltage Series Model (Cond / Eva Temp) (Cond / Eva Temp) Btu/hr Watts Watts Btu/W·hr W/W °F Btu/hr Watts Watts Btu/W·hr W/W °F A B C 1Φ, 220 / 240V ABT ABT034PT 28,000 8,201 2,888 9.7 2.84 130 / 45 444 421 315 ABT042YT 34,900 10,228 3,421 10.2 2.99 130 / 45 415 377 273 ABT048YT 40,200 11,781 3,688 10.9 3.19 130 / 45 444 421 315 ABT051YT 42,500 12,447 3,900 10.9 3.19 130 / 45 444 421 315 ABT ABT054YT 44,800 13,121 4,150 10.8 3.16 130 / 45 444 421 315 R410A LSS 50Hz 3Ф, ABT057YT 48,500 14,204 4,450 10.9 3.19 130 / 45 444 421 315 380 / 420V ABT061YT 51,500 15,083 4,725 10.9 3.19 130 / 45 444 421 315 ARA061YA 51,500 15,093 5,049 10.2 2.99 130 / 45 474 430 322 ARA073YA 62,000 18,170 6,020 10.3 3.02 130 / 45 470 426 322 ARA ARA073YB 63,000 18,463 5,833 10.8 3.17 130 / 45 461 412 308 ARA081YA 68,500 20,075 6,716 10.2 2.99 130 / 45 379 426 322 Note : COND 130℉(54.4℃), EVA 45℉(7.2℃) · ABT · ARA 31° 59° 31° 59° 119.8 114.9 234.5 234.5 117.2 Φ19 117.2 Φ19 95.2 95.2 190.5 190.5 DIS ID Φ12.7~12.9 DIS ID Φ12.7~12.9 SUC ID Φ22.3~22.5 SUC ID Φ22.3~22.5 A A B 303.3 B C Φ164.6 C Φ185.4 08 LG Scroll Compressor 09 Specification Fixed Speed R410A [2 of 5] Test condition Test condition Cooling capacity Input EER COP Cooling capacity Input EER COP Dimension (mm) Refrigerant Type Frequency Voltage Series Model (Cond / Eva Temp) (Cond / Eva Temp) Btu/hr Watts Watts Btu/W·hr W/W °F Btu/hr Watts Watts Btu/W·hr W/W °F A B C APA016KA 15,200 4,455 1,634 9.3 2.73 130 / 45 24,000 7,034 1,333 18.0 5.28 100 / 45 407 379 259 APA020KA 19,500 5,715 2,010 9.7 2.84 130 / 45 27,700 8,118 1,547 17.9 5.25 100 / 45 407 379 259 APA024KA 22,500 6,594 2,344 9.6 2.81 130 / 45 30,100 8,821 1,645 18.3 5.36 100 / 45 407 379 259 APA APA026KA 24,500 7,180 2,450 10.0 2.93 130 / 45 35,300 10,345 1,898 18.6 5.45 100 / 45 407 379 259 APA029KA 28,000 8,206 2,828 9.9 2.90 130 / 45 36,500 10,697 1,931 18.9 5.54 100 / 45 407 379 259 APA030KA 29,000 8,499 2,929 9.9 2.90 130 / 45 38,300 11,225 1,995 19.2 5.63 100 / 45 407 379 259 APA032KA 30,500 8,939 3,020 10.1 2.96 130 / 45 42,800 12,543 2,195 19.5 5.71 100 / 45 444 418 300 1Φ, ABA036KA 36,500 10,697 3,510 10.4 3.05 130 / 45 52,000 15,240 2,680 19.4 5.69 100 / 45 449 416 294 R410A LSS 60Hz 208-230V ABA042KA 42,500 12,456 4,048 10.5 3.08 130 / 45 58,500 17,145 3,000 19.5 5.71 100 / 45 449 416 294 ABA ABA049KA 48,000 14,067 4,528 10.6 3.11 130 / 45 63,000 18,463 3,231 19.5 5.71 100 / 45 449 416 294 ABA051KA 51,500 15,093 4,858 10.6 3.11 130 / 45 66,500 19,489 3,446 19.3 5.66 100 / 45 449 416 294 ABA054KA 54,000 15,826 5,143 10.5 3.08 130 / 45 449 416 294 ABT038KT 38,700 11,342 3,650 10.6 3.11 130 / 45 421 315 315 ABT042KT 42,200 12,359 3,980 10.6 3.11 130 / 45 421 315 315 ABT ABT048KT 48,000 14,058 4,444 10.8 3.16 130 / 45 421 315 315 ABT051KT 51,200 14,058 4,740 10.8 3.16 130 / 45 421 315 259 ABT054KA 54,000 15,815 4,820 11.2 3.28 130 / 45 421 315 300 Note : COND 130℉(54.4℃), EVA 45℉(7.2℃) / COND 100℉(37.8℃), EVA 45℉(7.2℃) · APA · ABA · ABT 31° 59° 31° 59° 31° 59° 119.8 119.8 104.4 114.9 114.9 106.7 234.5 234.5 234.5 117.2 Φ19 117.2 Φ19 117.2 Φ19 95.2 95.2 95.2 190.5 190.5 190.5 DIS ID DIS ID Φ12.70~12.9 Φ12.70~12.9 DIS ID Φ12.7~12.9 SUC ID SUC ID Φ22.3~22.5 Φ22.3~22.5 SUC ID Φ19.13~19.3 A B A A 303.3 303.3 C 258.8 B B Φ145.4 Φ164.6 Φ164.6 C C 10 LG Scroll Compressor 11 Specification Fixed Speed R410A [3 of 5] Test condition Test condition Cooling capacity Input EER COP Cooling capacity Input EER COP Dimension (mm) Refrigerant Type Frequency Voltage Series Model (Cond / Eva Temp) (Cond / Eva Temp) Btu/hr Watts Watts Btu/W·hr W/W °F Btu/hr Watts Watts Btu/W·hr W/W °F A B C APA APA032RA 30,000 8,792 3,030 9.9 2.90 130 / 45 38,100 11,166 2,016 18.9 5.54 100 / 45 379 259 300 ABA044RA 44,500 13,042 4,220 10.6 3.09 130 / 45 60,000 17,584 2,770 21.7 6.35 100 / 50 416 294 302 ABA ABA051RA 51,500 15,093 4,813 10.7 3.14 130 / 45 63,000 18,463 3,198 19.7 5.77 100 / 45 416 294 322 3Ф, ABA054RA 54,500 15,972 5,093 10.7 3.14 130 / 45 67,000 19,636 3,401 19.7 5.77 100 / 45 416 302 315 208-230V ARA ARA061RA 61,500 18,024 6,029 10.2 2.99 130 / 45 430 322 315 ABT044RM 44,000 12,895 4,151 10.6 3.11 130 / 45 421 315 315 ABT ABT054RM 54,000 15,826 4,910 11.0 3.22 130 / 45 421 315 315 ABT044UM 44,000 12,895 4,151 10.6 3.11 130 / 45 421 315 315 ABT048UM 48,300 14,146 4,555 10.6 3.11 130 / 45 421 315 315 ABT ABT048UT
Recommended publications
  • D-PAC Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency
    Digital Precise Air Control System D-PAC Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency AAON • 2425 South Yukon Avenue • Tulsa, Oklahoma 74107 • (918) 583-2266 • Fax (918) 583-6094 • www.aaon.com Total Control Indoor Air Quality and Comfort ndoor air quality (IAQ) and occupant comfort are two of the most Scroll compressor, return important factors to consider with any HVAC system design. One air bypass, and modulating ofI the leading causes of poor IAQ and occupant discomfort is too hot gas reheat for energy much moisture in the air, commonly referred to as high humidity. efficient load matching IAQ problems associated with high humidity include mold growth, humidity control. An AAON condensation and increased sickness and allergic reactions. As for D-PAC controller is also occupant comfort, the saying goes “It’s not the heat, it’s the humidity”. factory installed to provide Improving indoor air quality and occupant comfort by controlling optimum performance of the the humidity and the temperature will help with these problems, system. Thus, the D-PAC boost productivity, and even improve the general well-being of the system provides an energy occupants. efficient, cost effective solution for temperature One way to improve IAQ and occupant comfort is with uniform and humidity control. humidity and temperature control. Ideally indoor conditions should remain consistently around 75°F dry bulb and 45% relative humidity. This will keep the occupants comfortable and decrease the likelihood The Competition of IAQ issues. ome in the HVAC industry assume that as Energy Use theS dry bulb temperature ontrolling both temperature and humidity can be very energy is being controlled the intensive.
    [Show full text]
  • Scroll Compressor Modelling for Heat Pumps Using Hydrocarbons As Refrigerants Paul Byrne, Redouane Ghoubali, Jacques Miriel
    Scroll compressor modelling for heat pumps using hydrocarbons as refrigerants Paul Byrne, Redouane Ghoubali, Jacques Miriel To cite this version: Paul Byrne, Redouane Ghoubali, Jacques Miriel. Scroll compressor modelling for heat pumps using hydrocarbons as refrigerants. International Journal of Refrigeration, Elsevier, 2013, 41, pp.1-13. 10.1016/j.ijrefrig.2013.06.003. hal-00926697 HAL Id: hal-00926697 https://hal.archives-ouvertes.fr/hal-00926697 Submitted on 10 Jan 2014 HAL is a multi-disciplinary open access L’archive ouverte pluridisciplinaire HAL, est archive for the deposit and dissemination of sci- destinée au dépôt et à la diffusion de documents entific research documents, whether they are pub- scientifiques de niveau recherche, publiés ou non, lished or not. The documents may come from émanant des établissements d’enseignement et de teaching and research institutions in France or recherche français ou étrangers, des laboratoires abroad, or from public or private research centers. publics ou privés. Scroll compressor modelling for heat pumps using hydrocarbons as refrigerants Paul BYRNE*, Redouane GHOUBALI, Jacques MIRIEL Université Européenne de Bretagne Université de Rennes1, Laboratoire LGCGM, Equipe MTRhéo IUT Génie Civil, 3 rue du Clos Courtel, BP 90422, 35704 Rennes Cedex 7, France Phone: +33 2 23 23 42 97 - Fax: +33 2 23 23 40 51 * corresponding author: [email protected] ABSTRACT Hydrocarbons are today considered as promising alternatives to hydrofluorocarbons thanks to their low environmental impact and their easy implementation. However, some precautions have to be taken to thwart their flammability. European regulations impose to take stringent measures regarding components and to install heat pumps in unoccupied spaces.
    [Show full text]
  • Fluid Mechanical Modelling of the Scroll Compressor
    View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by Mathematical Institute Eprints Archive Fluid mechanical modelling of the scroll compressor by Peter Howell University of Oxford Mathematical Institute, 24{29 St Giles', Oxford OX1 3LB, UK Preface. This case-study concerns the flow of gas in a so-called Scroll Compressor. In this device a number of chambers of gas at different temperatures and pressures are separated by narrow channels through which leakage can occur. Using compressible lubrication theory, an estimate for the leakage rate is found in terms of the material properties of the gas and the geometry of the compressor. Thus a simple functional is obtained which allows the efficiency of different compressor designs to be compared. Next we derive a set of ordinary differential equations for the temperature and pressure in each chamber; the coupling between them arises from the leakage. The numerical solution of these equations allows a realistic simulation of a working compressor, and suggests some interesting possibilities for future designs. This problem arose at the 32nd European Study Group with Industry held in September 1998 at the Technical University of Denmark | the first ever to be held outside the United Kingdom. It was presented by Stig Helmer Jørgensen from DANFOSS, which is Denmark's largest industrial group and specialises in controls for refrigeration and heating. The Danish Study Group was a great success and is expected to be repeated annually henceforth. The feedback from DANFOSS has also been encouraging and hopefully this represents the start of a long-term collaboration.
    [Show full text]
  • Scroll Compressors
    SCROLL COMPRESSORS SF 1-6 (1.5-5.5 kW/2-7.5 hp) / SF+ 2-22 (2.2-22 kW/3-30 hp) PURE OIL-FREE AIR As there is no metal-to-metal contact between the compression scrolls, there is no need for oil lubrication in the compression chamber. Therefore, the scroll compression principle guarantees high-quality, oil-free air. As a result, the SF compressor is oil-free in every way. ENERGY EFFICIENCY COST-EFFICIENT, The SF scroll compressors, standard equipped with IE3 Premium efficiency motors, are suited for sensitive applications HIGH-QUALITY AIR which require flexibility and energy efficiency. Unloaded power consumption is eliminated thanks to the simple start/stop With its state-of-the-art oil-free compressor control. Advanced scroll technology guarantees an optimal technologies such as screw, tooth, centrifugal, free air delivery and low duty cycle applications. reciprocating and scroll, Atlas Copco provides the right solutions for your specific needs. EXTREMELY LOW NOISE LEVEL As oil-free compressed air is a prerequisite for The slow speed of the scroll compression elements ensures that many manufacturing processes, we ensure the SF scroll compressors are extremely quiet. Sound levels are consistent oil-free air by preventing oil from as low as 53 dB(a), making the SF the perfect choice for your sensitive working environment. entering your compressed air system. SIMPLICITY AND RELIABILITY + The SF and SF ranges of oil-free scroll The SF scroll compressors stand for simplicity and reliability. air compressors unite Atlas Copco’s vast The compressor has a minimal number of moving parts, experience and knowledge in a class-leading ensuring a long operating life with limited service interventions.
    [Show full text]
  • Copeland-Scroll-Compressor-Large-Zx
    Copeland Scroll™ Compressor Large ZX Condensing Unit & EMP Rack for Refrigeration Applications User Manual Copeland Scroll™ Large ZX Condensing Unit and EMP Rack Emerson is pleased to offer Copeland Scroll Large ZX Condensing Unit and EMP Rack for Refrigeration Applications. In addition to 2-9 HP condensing unit, Emerson expands Next Generation ZX platform to 12-20 HP medium temperature and low temperature condensing unit and rack, configuring with digital modulation for best in class energy efficiency and food safety. Emerson ZX series has been highly successful in global market and enjoys proven success with its energy savings and customer-friendly electronic features. Table of contents Overview 4 Nomenclature 7 Bill of material 8 Envelope 9 Technical data 11 Physical layout 13 CoreSense™ controller 17 Network wiring 26 Installation 29 Electrical connection 29 Refrigeration piping installation 29 Location and fixing 32 Start up and operation 35 Vacuuming 35 Charging procedure 35 Check before starting & during operation 37 Alarm codes 39 Troubleshooting 41 Temperature sensor resistance table 48 Wiring diagrams 49 Contact lists 52 Overview Disclaimer Thanks for purchasing Copeland Scroll™ Large ZX Condensing Unit and EMP Rack from Emerson. Large ZX Condensing Unit and EMP Rack exhibit market-leading quality in terms of cooling capacity and operating range, as part of product extension for Next Generation ZX platform in larger capacity range and installation variants. The product is designed to operate reliably and to deliver high operating efficiencies in medium and low temperature refrigeration applications. It also provides constant monitoring of the compressor operating conditions and displays the running or fault conditions of the condensing unit or rack.
    [Show full text]
  • Exergy Analysis and Thermodynamic Model for Reciprocating and Scroll Compressors Used in an Air Conditioning Packaged Unit
    Journal of Engineering and Development, Vol. 18, No.5, September 2014, ISSN 1813- 7822 Exergy Analysis and Thermodynamic Model for Reciprocating and Scroll Compressors Used in an Air Conditioning Packaged Unit Prof. Dr. Sabah Tarik Ahmad Prof. Dr. Wahid S. Mohammad Lecturer. Dr. Louay Abd-Alazez Mahdi Machine and Equipment department., University of Technology Abstract : An exergical thermodynamic model was used to analyze and optimize reciprocating and scroll compressors of an air condition packaged unit. The experimental work was carried out using 3.0 TR packaged unit manufactured by Carrier Company. The experimental and the analysis show that the exergy dissipative due to friction losses in bearings, suction and discharge valves and the transformation of power are larger than the heat losses. The exergy efficiency for the compressor was varying between (60-68) %. The scroll compressor was found to be better than the reciprocating compressor at an environmental temperature of 35℃ due to its low total losses which is 10% less than the reciprocating compressor ones . The heat losses percentages were 3% for scroll and 2% for the reciprocating of the total power input. The thermodynamic model has shown to be reliable in dealing with a change in the environmental temperatures and such system components and size. Keywords: Exergy analysis, thermodynamic model, reciprocating compressor, scroll compressor. ﺗﺣﻠﯾل ﻟﻠطﺎﻗﺔ اﻟﻣﺗﺎﺣﺔ ﻣﻊ ﻧﻣوذج ﺛرﻣودﯾﻧﺎﻣﯾﻛﻲ ﻟﻠﺿواﻏط اﻟﺗرددﯾﺔ و اﻻورﺑﯾﺗﺎﻟﯾﺔ ﻓﻲ وﺣدة ﺗﻛﯾﯾف ﻣﺟﻣﻌﮫ ا.د. ﺻﺒﺎح طﺎرق اﺣﻤﺪ ا.د. وﺣﯿﺪ ﺷﺎﺗﻲ ﻣﺤﻤﺪ م.د. ﻟﺆي ﻋﺒﺪ اﻟﻌﺰﯾﺰ ﻣﮭﺪي ﻗﺴﻢ ھﻨﺪﺳﺔ اﻟﻤﻜﺎﺋﻦ واﻟﻤﻌﺪات / اﻟﺠﺎﻣﻌﺔ اﻟﺘﻜﻨﻮﻟﻮﺟﯿﺔ اﻟﺧﻼﺻﺔ : ﺗﻢ اﺳﺘﺨﺪام ﻣﻮدﯾﻞ دﯾﻨﺎﻣﯿﻜﻲ ﺣﺮاري ﺑﺎﺳﺘﺨﺪام ﻣﺒﺪأ اﻟﻄﺎﻗﺔ اﻟﻤﺘﺎﺣﮫ (Exergy ) ﻟﺘﺤﻠﯿﻞ وﺗﺤﺪﯾﺪ أداء ﻧﻮﻋﯿﻦ ﻣﻦ اﻟﻀﻮاﻏﻂ اﻷول ﺗﺮددي واﻷﺧﺮ اورﺑﯿﺘﺎﻟﻲ ،ﻣﺜﺒﺘﯿﻦ ﻓﻲ ﺟﮭﺎز ﺗﻜﯿﯿﻒ ﺳﻌﺔ 3طﻦ ﺗﺒﺮﯾﺪ ﻣﺼﻨﻊ ﻣﻦ ﻗﺒﻞ ﺷﺮﻛﺔ Carrier .
    [Show full text]
  • High Performance Scroll Compressor with Liquid Refrigerant Injection H
    View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by Purdue E-Pubs Purdue University Purdue e-Pubs International Compressor Engineering Conference School of Mechanical Engineering 2002 High Performance Scroll Compressor With Liquid Refrigerant Injection H. Yamazaki Mitsubishi Heavy Industries Ltd T. Itoh Mitsubishi Heavy Industries Ltd K. Sato Mitsubishi Heavy Industries Ltd H. Kobayashi Mitsubishi Heavy Industries Ltd M. Kawada Mitsubishi Heavy Industries Ltd Follow this and additional works at: https://docs.lib.purdue.edu/icec Yamazaki, H.; Itoh, T.; Sato, K.; Kobayashi, H.; and Kawada, M., " High Performance Scroll Compressor With Liquid Refrigerant Injection " (2002). International Compressor Engineering Conference. Paper 1596. https://docs.lib.purdue.edu/icec/1596 This document has been made available through Purdue e-Pubs, a service of the Purdue University Libraries. Please contact [email protected] for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html C22-1 HIGH PERFORMANCE SCROLL COMPRESSOR WITH LIQUID REFRIGERANT INJECTION Hiroshi Yamazaki, Takahide Itoh, Kazuhiro Sato, Hiroyuki Kobayashi, Mitsubishi Heavy Industries Ltd., Nagoya Research & Development Center 1-Takamichi, Iwatsuka-cho, Nakmura-ku, Nagoya, Japan, 453-8515 Tel: 81-52-412-0899; Fax: 81-52-412-9162, E-mail: HiroshiYamazaki [email protected] Takahide Itoh [email protected] Kazuhiro Sato [email protected] Hiroyuki Kobayashi [email protected] Minoru Kawada, Mitsubishi Heavy Industries Ltd., Air-conditioning & Refrigerant Systems Headquarters, 3-1 Asahimachi, Nishibiwajima-cho, Nishi-Kasugai-Gun, Japan, 452-8561 Tel: 81-52-503-9217; Fax: 81-52-501-5629, E-mail: [email protected] ABSTRACT Improvement of compressor efficiency using the alternative refrigerant is demanded strongly to reduce CO2 emission, which causes the global warming.
    [Show full text]
  • Commercial and Residential Water Source Heat Pumps Boiler/Tower and Geothermal Applications SOLUTION 1
    Commercial and Residential Water Source Heat Pumps Boiler/Tower and Geothermal Applications SOLUTION 1 WATER-SOURCE HEAT PUMPS WINTER WARM-UP Water-Loop heat pump systems combine water-source heat During recovery from night setback, most zones will require pumps on a common piping loop with a heat rejector and heating and will be extracting heat from the water loop. boiler, which are used to maintain the circulating water The boiler maintains the minimum water loop temperature temperature within a controlled range, typically from according to a predetermined setpoint. The heat rejector is off. 15°C to 35°C. The most common heat rejectors are open The warm-up period is typically one hour or less per day. cooling towers with isolating heat exchangers, closed-circuit evaporative coolers, or dry coolers. Boilers are usually gas, oil, or electric. Each zone heat pump utilizes the water loop to provide heating or cooling at any time, during or after hours, regardless of the operating mode of the other heat pumps. This is accomplished without duplicate heat and cool distribution systems, without the double waste inherent in reheat modes, and without concurrent operation of the cooling source and boiler, unlike most HVAC systems that provide the same capabilities. Water-loop heat pump systems also operate very effi ciently at part-load conditions, such as when a small portion of the WINTER OCCUPIED building remains occupied after hours. Only the required Most core zones will require cooling because of the internal zone heat pumps are used, unlike systems that must keep a heat gains discussed previously.
    [Show full text]
  • CFD Simulation of an Oil Flooded Scroll Compressor Using VOF Approach Hui Ding Simerics Inc., United States of America, [email protected]
    Purdue University Purdue e-Pubs International Compressor Engineering Conference School of Mechanical Engineering 2016 CFD Simulation of An Oil Flooded Scroll Compressor Using VOF Approach Hui Ding Simerics Inc., United States of America, [email protected] Yu Jiang Simerics Inc., United States of America, [email protected] Follow this and additional works at: https://docs.lib.purdue.edu/icec Ding, Hui and Jiang, Yu, "CFD Simulation of An Oil Flooded Scroll Compressor Using VOF Approach" (2016). International Compressor Engineering Conference. Paper 2508. https://docs.lib.purdue.edu/icec/2508 This document has been made available through Purdue e-Pubs, a service of the Purdue University Libraries. Please contact [email protected] for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html 1616, Page 1 CFD Simulation of An Oil Flooded Scroll Compressor Using VOF Approach Hui Ding*, Yu Jiang Simerics Inc., 1750 112th Ave NE Ste A203, Bellevue, WA 98004, USA Phone – 425-502-9978, Fax – 425-502-9978, E mail – [email protected] * Corresponding Author ABSTRACT Liquids have been commonly used in different types of compressors to cool the compressed gas and to seal the leakage gaps in order to increase the efficiency. CFD simulation provides valuable insights to help design engineers to verify, to analyze, and to improve the performance of a compressor. However two phase flow with moving parts and small gaps is a very challenging CFD problem. For compressor simulation, thermal effects and heat transfer are also essential.
    [Show full text]
  • Analysis of the Inner Fluid-Dynamics of Scroll Compressors and Comparison Between CFD Numerical and Modelling Approaches
    energies Article Analysis of the Inner Fluid-Dynamics of Scroll Compressors and Comparison between CFD Numerical and Modelling Approaches Giovanna Cavazzini * , Francesco Giacomel, Alberto Benato , Francesco Nascimben and Guido Ardizzon Department of Industrial Engineering, University of Padova, 35131 Padova, Italy; [email protected] (F.G.); [email protected] (A.B.); [email protected] (F.N.); [email protected] (G.A.) * Correspondence: [email protected]; Tel.: +39-049-827-6800 Abstract: Scroll compressors are widely adopted machines in both refrigeration systems and heat pumps. However, their efficiency is basically poor and constitutes the main bottleneck for improving the overall system performance. In fact, due to the complex machine fluid dynamics, scroll design is mainly based on theoretical and/or semi-empirical approaches. Designs strategies that do not guarantee an in-depth analysis of the machine behavior can be supplemented with a Computation Fluid Dynamics (CFD) approach. To this purpose, in the present work, the scroll compressor inner fluid dynamics is numerically analyzed in detail using two CFD software and two different modelling strategies for the axial gap. The analysis of the fluid evolution within the scroll wraps reveals unsteady phenomena developing during the suction and discharge phases, amplified by the axial clearance with negative impact on the main fluid flow (e.g., −13% of average mass flow rate for an axial gap of 30 µ) and on the scroll performance (e.g., +26% of average absorbed power for an axial gap of 30 µ). In terms of accuracy, the k-" offers good performance on the estimation of average quantities Citation: Cavazzini, G.; Giacomel, F.; but proves to be inadequate for capturing the complexity of the unsteady phenomena caused by the Benato, A.; Nascimben, F.; Ardizzon, G.
    [Show full text]
  • Overall Scroll Compressor Modeling Y
    Purdue University Purdue e-Pubs International Compressor Engineering Conference School of Mechanical Engineering 2000 A Comprehensive Model of Scroll Compressors Part II: Overall Scroll Compressor Modeling Y. Chen Purdue University N. P. Halm Purdue University E. A. Groll Purdue University J. E. Braun Purdue University Follow this and additional works at: https://docs.lib.purdue.edu/icec Chen, Y.; Halm, N. P.; Groll, E. A.; and Braun, J. E., "A Comprehensive Model of Scroll Compressors Part II: Overall Scroll Compressor Modeling" (2000). International Compressor Engineering Conference. Paper 1456. https://docs.lib.purdue.edu/icec/1456 This document has been made available through Purdue e-Pubs, a service of the Purdue University Libraries. Please contact [email protected] for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html A Comprehensive Model of Scroll Compressors Part II: Overall Scroll Compressor Modeling Yu Chen Nils P. Halm Eckhard A. Groll James E. Braun School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907 This paper presents the development of a comprehensive scroll compressor model which combines a detailed compression process model (Chen et al, 2000) and an overall compressor model. In the overall model, compressor components are analyzed in terms of nine different elements. Steady state energy balance equations are established applying the lumped capacitance method. In combination with the detailed compression process model, these equations were implemented into computer code and solved iteratively. In this way, the temperature and pressure of the refrigerant in different compressor chambers, the temperature distributions in the scroll wraps, and the temperatures of the other compressor elements can be obtained.
    [Show full text]
  • A Co-Rotating Scroll Compressor for Positive Displacement and Centrifugal Dual-Mode Operations E
    View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by Purdue E-Pubs Purdue University Purdue e-Pubs International Compressor Engineering Conference School of Mechanical Engineering 1994 A Co-Rotating Scroll Compressor for Positive Displacement and Centrifugal Dual-Mode Operations E. Morishita The University of Tokyo M. Sekiya Mitsubishi Electric Industrial Corporation 0 Yatsuki Mitsubishi Electric Industrial Corporation Follow this and additional works at: https://docs.lib.purdue.edu/icec Morishita, E.; Sekiya, M.; and Yatsuki, 0, "A Co-Rotating Scroll Compressor for Positive Displacement and Centrifugal Dual-Mode Operations" (1994). International Compressor Engineering Conference. Paper 1054. https://docs.lib.purdue.edu/icec/1054 This document has been made available through Purdue e-Pubs, a service of the Purdue University Libraries. Please contact [email protected] for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html A CO-ROTATING SCROLL COMPRESSOR FOR POSITIVE DISPLACEMENT AND CENTRIFUGAL DUAL-MODE OPERATIONS Et;suo lfORISHIXA Department of Aeronautics & Astronautics Faculty of Engineering, the University of Tokyo 7-3-1, Hongo, Bunkyo-ku, Tokyo 113, JAPAN llut:suo SEKIYA Osa.u YATSUKI Sanda Works, Mitsubishi Electric Corporation 2-3-33, Miwa, Sanda, Hyogo 669-13, JAPAN ABSTRACT The co-rotating mechanism is utilized for scroll vacuum pump application by one of the authors. It was found that the co­ rotating scroll compressor is transformed to a centrifugal com­ pressor by reducing the eccentricity between the two scrolls to zero.