Collie Power Station Wastewater Management and Disposal System
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
GRIFFIN ELECTRICITY PTY LTD Collie B Power Station
GRIFFIN ELECTRICITY PTY LTD Collie B Power Station (Collie B) Proponent’s Response to Submissions April 2005 Table of Contents 1 SUMMARY OF SUBMISSIONS RECEIVED........................................................ 1 2 NOISE................................................................................................................... 3 3 SURFACE WATER AND GROUNDWATER ....................................................... 7 4 FLORA AND FAUNA ......................................................................................... 12 5 ATMOSPHERIC EMISSIONS ............................................................................ 13 6 GREENHOUSE ISSUES .................................................................................... 29 7 LIQUID AND SOLID WASTE DISPOSAL.......................................................... 38 8 SOCIAL AND HERITAGE ISSUES.................................................................... 51 9 OTHER ISSUES ................................................................................................. 52 10 GLOSSARY........................................................................................................ 56 11 BIBLIOGRAPHY ................................................................................................ 59 Collie B Power Station – Responses to Issues raised in Submissions Page i List of Tables Table 1 – Summary of Noise Levels ...................................................................................3 Table 2 - Collie Power Station Sound Power Level............................................................4 -
University of Southern Queensland Facility of Health, Engineering And
University of Southern Queensland Facility of Health, Engineering and Sciences Low Load Frequency Support Capability - Collie Power Station A dissertation submitted by Alan Christian Cornish In fulfillment of the requirements of ENG4111 and 4112 Research Project towards the degree of Bachelor of Power Engineering (Honours) Submitted: October 2020 Abstract Energy markets around the world are in a transitional phase, where wind and solar generation are penetrating the markets at unforeseen rates. The desire to decarbonise emissions associated with power generation in Australia, is seen as the first step in meeting our commitments to the Paris Climate Change Agreement. This has had a significant effect upon the electricity grid within Western Australia. The high volume of renewable generation is creating grid instability during times of low demand. This is a result of fluctuations in generation due to the variability of wind and solar. Network strength is no longer as robust because of the loss of synchronous inertia that was behind a grid mainly powered by thermal machines. Many coal fired stations are attempting to become more flexible and change from base load to cyclical operation to assist counteract the irregular nature of wind and solar generation. Collie Power Station is one such station, attempting to improve its operational flexibility. One aspect is the desire that the station move from a current minimum load setpoint of 130MW to 105MW (generated) to assist the station remain dispatched at low load rather than desynchronising it from the grid. The aim of this dissertation is to model the frequency support capability at 105MW to determine if the station continues to provide frequency support for the grid. -
2014-11-25 QWON Power Stations
LEGISLATIVE COUNCIL C1379 QUESTION WITHOUT NOTICE (Of which some notice has been given) Tuesday, 25 November 2014 Hon Robin Chapple to the Leader ofthe House representing the Minister for Energy. Please provide a summary of all active power stations in Western Australia, including: age; capacity profile; fuel and/or mine type; number of employees; whether it is on or off the grid; and the closure schedule. I thankthe Hon. Member for some notice of this question. I table the attached document. The Public Utilities Office has relied on the Independent Market Operator for data concerning generators on the SWIS and has reported the maximum sent out capacity offered by these facilities into the Balancing Market, as of 25 November 2014. These figures may differ slightly from the number of capacity credits awarded and from facility nameplate capacity owing to factors including parasitic load and ambient temperature. For NWIS and NIS facilities, various sources have been used as there is no single definitive list of facilities. The nature of mining operations has not been investigated. The Public Utilities Office does not have access to data on the number of employees or on the closure schedule of power stations. The expected plant life of power stations is variable, a function of maintenance regimes and commercial considerations. ATTACHMENT TO QWN C1379 . 'I . " ~ -1J&1t~-n i ~,'l;(, : 'C' 4\", lTt ~A','~:'l';"(~.i~ffil!. " l]f,:,gl '~. l) , '. lifP'\1 ~, , •. 'fg~~t:t.: :' (~~.~:~n.', . ~ j - llll' ~!l!i:jliiW~tlilit~r~QJ\l1~~t~ii~Sys:t~m;(~~),~'•. -
Answers to Questions Prior to Hearing
Hon Mike Nahan MLA Treasurer; Minister for Energy; Citizenship and Multicultural Interests Ourref: 48-13528; 48-13527 Hon Ken Travers MLC Chairman Estimates and Financial Operations Committee Parliament House PERTH WA 6000 Attn: Mr Mark Warner Committee Clerk Dear Mr Travers QUESTIONS PRIOR TO 2014-15 ANNUAL REPORT HEARINGS - SYNERGY AND HORIZON POWER In response to the Committee's letter of 20 October 2015, please find attached responses to the questions prior to hearing, in respect of Synergy and Horizon Power's 2014-15 annual report. Yours sincerely DR MIKE NAHAN MLA TREASURER Att. CC: Hon Peter Collier MLC Minister representing the Minister for Energy in the Legislative Council 1 9 NOV 2015 Level 13, Dumas House, 2 Havelock Street, West Perth, Western Australia 6005 Telephone: +61 8 6552 5700 Facsimile: +61 8 6552 5701 Email: [email protected] ESTIMATES AND FINANCIAL OPERATIONS COMMITTEE 2014/15 ANNUAL REPORT HEARINGS QUESTIONS PRIOR TO HEARING Synergy Annual Report 2014/15 Hon Robin Chappie asked: 1) Page 5 under "Our Business," I ask: a) How many people are employed at each of your nine power stations? Answer: Employees (2014-15) Cockbum Power Station 19 Kalgoorlie Gas Turbine Mungarra Gas Turbine 5 Pinjar Power Station Kwinana Power Station (includes Kwinana Gas Turbines) 11 Geraldton Gas Turbine 0 Worsley (South West Co-Generation Joint Venture) 0 (operated by Worsley Alumina) Muja Power Station 337 Collie Power Station 1 FTE + contractors as required. How many people are employed at each of your nine wind farms? Answer: Employees (2014-15) Albany Wind Farm Bremer Bay Wind-Diesel System 4 Esperance Wind Farms Hopetoun Wind-Diesel System Coral Bay Wind-Diesel System 2 Denham Wind-Diesel System 2 Kalbarri Wind Farm 1 Mumbida Wind Farm 6 How many people are employed at your one solar farm? Answer: Employees (2014-15) Greenough River Solar Farm 1.5 2) Page 21 under "Delivering energy" you describe two station transformers failing and a partial cooling tower collapse at Muja Power Station, I ask: a) Have these issues been rectified? Answer: Yes. -
Carbon Emissions Inventory Major Resource Projects – AGEIS 2012
FACILITIES CURRENTLY OPERATING Name/Location; Facility name, Operator Scope 1 (Direct) Source of data General activity GHG emissions Point source CO2e TPA emissions total, where stationary energy is accounted for elsewhere (eg Power derived from SWIS) Alkimos Wastewater Treatment Water Corporation Plant Sourced from SWIS 16,000 EPA Bulletins 1238, 1239 Argyle, diamonds Rio Tinto Argyle Diamonds sustainable development 49,000 report 2009 and 2010 Armadale Brick Austral Bricks Data provided by Company giving their (Brickworks Ltd) 42,968 state total emissions Cardup Brick Austral Bricks (Brickworks Ltd) see Armadale Brick Caversham Tile Bristile (Brickworks Ltd) see Armadale Brick Malaga Brick Austral Bricks (Brickworks Ltd) see Armadale Brick Australind; titanium Cristal Global Sourced from SWIS 34,000 Company report (June 2009) Boddington; Mt Saddleback, BHP Billiton - Worsley bauxite Alumina Pty Ltd 243,000 AAC Sustainability report 2009 Bonaparte Basin; Blacktip gas ENI Australia project not known Bonaparte Basin; Puffin, oil AED Oil Ltd (in administration) not known Brockman Syncline 4 Iron Ore Rio Tinto (form. Project Hamersley Iron Pty Limited) 111,800 EPA Bulletin 1214 WA GREENHOUSE GAS EMISSIONS Page 2 Bronzewing - Mt McClure, gold Navigator Resources Ltd not known Burrup; Ammonia Plant, Burrup Burrup Fertilisers Pty NGER Greenhouse and Energy Information Peninsula Ltd 1,484,877 2010-11 Canning Basin; Blina, Lloyd, Buru Energy Ltd Sundown & West Terrace, oil 244 Data provided by Company Cape Preston; Central Block, Sino Iron (CITIC) -
P6252b-6253A Hon Robin Chapple; Hon Peter Collier ENERGY
Extract from Hansard [COUNCIL — Tuesday, 15 September 2015] p6252b-6253a Hon Robin Chapple; Hon Peter Collier ENERGY — POWER PURCHASE AGREEMENTS 3306. Hon Robin Chapple to the Leader of the House representing the Minister for Energy: (1) Will the Minister provide a list of all of the Power Purchase Agreements signed in the last ten years, detailing which companies were contracted, for what capacity, which fuel was to be used in the electricity generation and what proportion overall is from renewable sources? (2) Will the Minister provide a list of all the coal fired power stations, including the various stages of those plants, in the South West interconnected system and the year that they were built? (3) Will the Minister outline the life expectancy of a coal fired power station? (4) For the coal fired power stations owned by Synergy, will the Minister outline the availability of these plants over the last five years taking into account all downtime due to planned and unplanned maintenance? (5) For the coal fired power stations owned by Synergy, will the Minister outline the expected timeline for the closure of those power stations, given that many of them have exceeded their initial life expectancy? (6) How much has Synergy spent on maintenance, including all refurbishments and upgrades on its coal fired power stations over the last five years? Hon Peter Collier replied: (1) No, this information is commercial in confidence. (2) The table below details all of the coal fired power station units currently operational in the South West Interconnected -
Muja AB Power Station Refurbishment - Technical Review - RFQ FIN13047
ATTACHMENT 2 )d.011-16 Client: Public Utilities Office Title: Muja NB Power Station Refurbishment - Technical Review Subtitle: RFQ FIN13047 Document No: 2158941A-DMS-RPT-001 Date: 26 August 2013 A 16/08/2013 Draft Report 0 26/08/2013 Final Report to Public Utilities Office ■ 4Ni_oi)ro) ; i'k=\,-4(=-0 '=:11;•=.iit.;, l 'i-:°Thir°1'.0'3-i-r1L-• L Robertson - Prepared by: M Rudge Date: 26/08/2013 Signature: B Jarman Reviewed by: N McGimpsey Date: 26/08/2013 Signature: /7:Y2.____ Approved by: A Crichton Date: 26/08/2013 Signature: ,,--!/ ,-- -. D11,10141 Public Utilities Office, Parsons Brinckerhoff file, Parsons Brinckerhoff Library This document and the information are solely for the use of the authorised recipient and this document may not be used, copied or reproduced in whole or part for any purpose other than that for which it was supplied by Parsons Brinckerhoff. Parsons Brinckerhoff makes no representation, undertakes no duty and accepts no responsibility to any third party who may use or rely upon this document or the information. The intellectual property of any new material (but excluding any Existing Material of Parsons Brinckerhoff) contained in this document is owned by the State of Western Australia. Parsons Brinckerhoff Australia Pty Limited ABN 80 078 004 798 Level 5 503 Murray Street Perth WA 6000 PO Box 7181 Cloisters Square WA 6850 Australia Tel: +61 8 9489 9700 Fax: +61 8 9489 9777 Email: perth©pb.com.au www.pbworld.corn Certified to ISO 9001, ISO 14001, AS/NZS 4801 A GRI Rating: Sustainability Report 2011 Public Utilities Office Muja NB Power Station Refurbishment - Technical Review - RFQ FIN13047 onten s Page number Executive summary iv 1. -
Collie Power Station Expansion
Collie Power Station Expansion Wesfarmers Energy Limited Report and recommendations of the Environmental Protection Authority Environmental Protection Authority Perth, Western Australia Bulletin 1178 June 2005 Environmental Impact Assessment Process Timelines Date Progress stages Time (weeks) 17/11/04 Level of assessment set (following any appeals upheld) 2 24/01/05 Proponent document released for public comment 10 21/03/05 Public comment period closed 8 10/05/05 Final proponent response to the issues raised 7 13/06/05 EPA report to the Minister for the Environment 5 ISBN. 0 7307 6818 X ISSN. 1030 - 0120 Assessment No. 1542 Summary and recommendations Wesfarmers Energy Limited proposes to construct and operate a 300MW coal-fired power station (known as Collie B) as an expansion of the existing Collie Power Station (known as Collie A). The Collie Power Station site is located approximately 10km east-north-east of Collie, Western Australia. This report provides the Environmental Protection Authority’s (EPA’s) advice and recommendations to the Minister for the Environment on the environmental factors relevant to the proposal. Section 44 of the Environmental Protection Act, 1986 requires the EPA to report to the Minister for the Environment on the environmental factors relevant to the proposal and on the conditions and procedures to which the proposal should be subject, if implemented. In addition, the EPA may make recommendations as it sees fit. Relevant environmental factors The EPA decided that the following environmental factors relevant to the proposal required detailed evaluation in this report: (a) Greenhouse gas emissions; (b) Atmospheric emissions; (c) Liquid and solid waste disposal; (d) Surface water and groundwater; and (e) Noise. -
Annual Report 2005 Western Power Annual Report 2005
embracing the future Western Power annual report 2005 Western Power Annual Report 2005 operations review YEAR IN REVIEW Chairman’s AND MANAGING DIRECTor’s YEAR IN REVIEW 2 NETWORKS BUSINESS UNIT 6 GENERATION BUSINESS UNIT 12 RETAIL BUSINESS UNIT 19 REGIONAL BUSINESS UNIT 22 REVIEW OF FINANCIAL PERFORMANCE 27 ELECTRICITY REFORM 29 OUR COMPANY OUR COMPANY IN 2005 31 AREAS SERVICED BY WESTERN POWER 32 STATEMENT OF CORPORATE PRIORITIES 33 OUR ORGANISATIONAL STRUCTURE 34 KEY RESULT AREAS CORPORATE RESULT AREAS 35 CORPORATE FACTS AND FIGURES 38 GLOSSARY 41 ELECTRICITY CORPORATION ACT 1994 42 financial review STATISTICAL SUMMARY 44 DIRECTORS’ REPORT 45 STATEMENT OF FINANCIAL PERFORMANCE 64 STATEMENT OF FINANCIAL POSITION 65 STATEMENT OF CASH FLOWS 66 NOTES TO AND FORMING PART OF THE FINANCIAL STATEMENTS FOR THE YEAR ENDED 30 JUNE 2005 67 DIRECTORS’ DECLARATION 117 INDEPENDENT AUDIT REPORT 118 Chairman’s and Managing Director’s Year In Review Neil Hamilton Chairman Tony Iannello Managing Director The WA energy industry has undergone • made a commitment to build our capabilities, both revolutionary change over the past 1 months. At people and systems. the centre of that change, Western Power has been With these changes and challenges, Western Power has challenged to deliver safe, reliable and efficient continued to perform strongly, achieving solid profits for energy services while positioning the organisation the eleventh consecutive year and delivering significant for a competitive and dynamic market. We have dividends to our shareholder, the State of Western needed to respond quickly and positively to energy Australia. We have approached the challenges set by reforms while working towards restoring confidence the events of the previous year with enthusiasm and among our customers and the Western Australian commitment and have successfully shown that we are able community. -
Electricity Generation Performance Audit Report & Asset Management
McGill Engineering Services Pty Ltd Engineering, Adjudication & Arbitration Services ABN 45 106 691 169 Electricity Generation performance audit report & Asset management system review Verve Energy EGL 7 Prepared By Kevan McGill Date 25 September 2008 McGill Engineering Services Pty Ltd Page 1 Performance Audit & Asset Management System Review EGL 7 Contents Contents ............................................................................................................................3 Executive Summary...........................................................................................................4 Overall conclusion..........................................................................................................4 Performance audit ......................................................................................................4 Asset Management Review........................................................................................4 Ratings .......................................................................................................................5 Findings......................................................................................................................5 Performance Audit and Asset Management Review .........................................................6 Performance Audit Objectives .......................................................................................6 Asset Management System Review Objectives.........................................................6 -
2020 Annual Report of the Electricity Generation and Retail Corporation, Trading As Synergy
Synergy Annual Report 2020 Annual Report ABN 58 673 830 106 ANNUAL 2020 REPORT In accordance with the Electricity Corporations Act 2005 (the Act), I have the pleasure in submitting the 2020 Annual Report of the Electricity Generation and Retail Corporation, trading as Synergy. Consistent with the provisions of the Act, Synergy will publish this document upon advice from the Minister. Yours sincerely, Robert Cole Chairman Synergy ABN 58 673 830 106 Manager public affairs and corporate communications, GPO Box F366, Perth WA 6841 email: [email protected] | website: synergy.net.au About Synergy 2 Chairman’s report 3 Chief Executive Officer’s report 4 Executive team 5 Operating and financial summary 7 Our customers and community 10 Our operations 16 Our people 22 Directors’ report 28 Financial report 41 Directors' declaration 87 Independent Auditor’s report 88 2020 Annual Report 1 Coral Bay Western Australia Denham Legend Kalbarri South West Interconnected System (SWIS) Mungarra Thermal power station West Kalgoorlie Wind farm Pinjar PERTH Gas turbine Cockburn Solar farm Collie Muja Hopetoun Esperance Bremer Bay Albany Synergy is proud to be Synergy owns and operates both Australia. These include the 180MW traditional and renewable electricity Warradarge Wind Farm, the Stage two Western Australia’s generating assets, including thermal 30MW expansion of the Greenough largest integrated power stations, spanning from River Solar Farm in the State’s Mid electricity generator Kalbarri in the north, out to Kalgoorlie West and the refurbishment of the in the east and down to Albany in the Albany Grasmere Wind Farm. and energy retailer. -
The Development of Annual and Peak Gas Demand Forecasts for the Western Australian Gas Market
F, REPORT 4 DECEMBER 2017 THE DEVELOPMENT OF ANNUAL AND PEAK GAS DEMAND FORECASTS FOR THE WESTERN AUSTRALIAN GAS MARKET Prepared for the Australian Energy Market Operator Marsden Jacob Associates Financial & Economic Consultants ABN 66 663 324 657 ACN 072 233 204 Internet: http://www.marsdenjacob.com.au E-mail: [email protected] Melbourne office: Postal address: Level 4, 683 Burke Road, Camberwell Victoria 3124 AUSTRALIA Telephone: 03 9882 1600 Facsimile: 03 9882 1300 Perth office: Level 1, 220 St Georges Terrace, Perth Western Australia, 6000 AUSTRALIA Telephone: 08 9324 1785 Facsimile: 08 9322 7936 Sydney office: 119 Willoughby Road, Crows Nest New South Wales, 2065 AUSTRALIA Rod Carr 0418 765 393 Authors: Grant Draper [email protected] Phil Jones [email protected] Peter McKenzie [email protected] Hana Ramli [email protected] This report has been prepared in accordance with the scope of services described in the contract or agreement between Marsden Jacob Associates Pty Ltd ACN 072 233 204 (MJA) and the Client. Any findings, conclusions or recommendations only apply to the aforementioned circumstances and no greater reliance should be assumed or drawn by the Client. Furthermore, the report has been prepared solely for use by the Client and Marsden Jacob Associates accepts no responsibility for its use by other parties. Copyright © Marsden Jacob Associates Pty Ltd 2017 Australian Energy Market Operator 2. Gas Demand Forecasts TABLE OF CONTENTS Introduction .................................................................................................................