Application Bulletin: Smoke, Heat, and Duct Detectors

Total Page:16

File Type:pdf, Size:1020Kb

Application Bulletin: Smoke, Heat, and Duct Detectors Smoke, Heat, and Duct Detectors Application Bulletin P/N 3101212 • REV 02 • REB 26JUL13 Copyright © 2013 UTC Fire & Security Americas Corporation, Inc. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without prior written consent from UTC Fire & Security Americas Corporation, Inc., except where specifically permitted under US and international copyright law. Disclaimer The information in this document is subject to change without notice. UTC Fire & Security Americas Corporation, Inc. assumes no responsibility for inaccuracies or omissions and specifically disclaims any liabilities, losses, or risks, personal or otherwise, incurred as a consequence, directly or indirectly, of the use or application of any of the contents of this document. For the latest documentation, contact your local supplier or visit us online at www.edwardssignaling.com. This publication may contain examples of screen captures and reports used in daily operations. Examples may include fictitious names of individuals and companies. Any similarity to names and addresses of actual businesses or persons is entirely coincidental. Trademarks and patents The Edwards Signaling name and logo are registered trademarks of UTC Fire & Security Americas Corporation, Inc. Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products. Intended use Use this product only for the purpose it was designed for; refer to the data sheet and user documentation for details. For the latest product information, contact your local supplier or visit us online at www.edwardssignaling.com. FCC compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. You are cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Content Under floor installations • 24 Related documentation • ii Effects of heating, ventilating, and air conditioning (HVAC) systems • 25 Overview of smoke, heat, and duct detectors • 1 Door release service • 26 Smoke detector locations • 26 Heat detector applications • 3 Introduction • 3 Duct smoke detector E-HD Fixed-Temperature/Rate of Rise applications • 27 Heat Detector • 3 Introduction • 27 Spacing of heat detectors • 3 E-PDD Duct Smoke Detector Ceiling height and construction • 7 installation guidelines • 27 Exposed solid joists • 8 Air sampling tube • 28 Exposed beams • 10 Air velocity • 29 Sloped ceilings • 12 Avoidance of false alarms • 29 Smoke detector applications • 14 Initial installation testing • 30 Introduction • 14 Duct smoke detector initial installation E-PD Photoelectric Smoke test • 30 Detector • 14 E-PHD multi-sensor smoke Sensitivity readings • 34 detector • 14 Avoidance of false alarms • 15 Routine maintenance • 35 Spacing of smoke detectors • 17 Scheduled testing • 35 Stratification • 17 Detector cleaning procedure • 37 Partitions • 19 Recalibrate a device and record Exposed solid joists • 19 detector sensitivity and available Exposed beams • 21 compensation • 39 Sloped ceilings • 23 High air movement • 23 Smoke, Heat, and Duct Detectors Application Bulletin i Related documentation National Fire Protection Association (NFPA) 1 Batterymarch Park R P.O. Box 9101 NFPA Quincy, MA 02269-9101 NFPA 70 National Electric Code NFPA 72 National Fire Alarm Code N FPA 90A Installation of Air conditioning and Ventilating Systems Underwriters Laboratories, Inc. (ULI) U 333 Pfingsten Road R L Northbrook, IL 60062-2096 UL 38 Manually Actuated Signaling Boxes UL217 Smoke Detectors, Single & Multiple Station UL 228 Door Closers/Holders for Fire Protective Signaling Systems UL 268 Smoke Detectors for Fire Protective Signaling Systems UL 268A Smoke Detectors for Duct Applications UL 346 Waterflow Indicators for Fire Protective Signaling Systems UL 464 Audible Signaling Appliances UL 521 Heat Detectors for Fire Protective Signaling Systems UL 864 Standard for Control Units for Fire Protective Signaling Systems UL 1481 Power Supplies for Fire Protective Signaling Systems UL 1638 Visual Signaling Appliances UL 1971 Visual Signaling Appliances Underwriters Laboratories of Canada (ULC) 7 Crouse Road R Scarborough, Ontario M1R 3A9 ULC S527 Standard for Control Units for Fire Alarm Systems ULC S524 Standard for the Installation of Fire Alarm Systems ULC S529 Smoke Detectors for Fire Alarm Systems ULC S536 Standard for the Inspection and Testing of Fire Alarm Systems ULC S537 Standard for the Verification of Fire Alarm Systems NEMA Guide for Proper Use of Smoke Detectors in Duct Applications PLUS... Requirements of state and local building codes Requirements of the Authority Having Jurisdiction ii Smoke, Heat, and Duct Detectors Application Bulletin Overview of smoke, heat, and duct detectors Overview of smoke, heat, and duct detectors This group of detectors comprises of a variety of detection technologies available in various combinations to meet the needs of the fire protection community. The smoke and heat detectors are constructed of a white, high-impact polymer and plug into one of a variety of mounting bases that feature base locking tabs. The duct smoke detectors are constructed of a black, high-impact polymer with a clear plastic cover and attach directly to the HVAC system duct. The table below lists the available detector models. Smoke, heat, and duct detectors Model Description E-PD Photoelectric smoke detector E-PHD Combination photoelectric smoke and 135°F (57°C) fixed-temperature heat detector E-HD Combination 135°F (57°C) fixed- temperature and 15°F (8°C) per minute rate-of-rise heat detector E-PDD Duct smoke detector The smoke and heat detectors are analog addressable devices that contain their own microprocessors, which allow them to make alarm decisions based on the information collected by their sensors. Depending on the detector, decisions may be based on the information gathered by up to two independent sensing elements. The address of each detector is assigned using the two rotary switches located on the detector. These detectors provide LEDs that indicate the detector’s condition. In normal condition, the network control panel performs background supervision indicated by the flashing green LED. An alarm condition is indicated by the flashing red LED. Multiple sensing technologies are incorporated into E-PHD and E-HD detectors, which makes them suitable for a wide range of applications. The tables in the Heat detector applications section of this document list the applications suitable for the E-PHD and E-HD. Tables in the Smoke detector applications section list the applications suitable for the E-PD and E-PHD. The Smoke, Heat, and Duct Detectors Application Bulletin 1 Overview of smoke, heat, and duct detectors Duct smoke detector applications section of this document lists the applications suitable for the E-PDD. E-PD, E-PHD, and E-PDD detectors offer a variety of sensitivity settings. The alarm sensitivity is the minimum obscuration level at which the detector will initiate an alarm condition. The alarm sensitivity level may be changed to any of five sensitivity settings using front panel programming or the configuration utility. All smoke detectors offer alarm verification, which is used to validate an alarm condition before it is processed by the control panel. When enabled, the alarm verification function tries to reset a detector that has initiated an alarm condition. If the detector cannot be reset or if it returns to its alarm condition within the required time window, the alarm is considered valid and is processed by the control panel. 2 Smoke, Heat, and Duct Detectors Application Bulletin Heat detector applications Heat detector applications Introduction WARNING: This detector is intended for use with ionization and/or photoelectric smoke detectors. The heat detector by itself does not provide life safety protection. Heat detectors sense a change in air temperature and initiate alarms based on a fixed-temperature point, rate of temperature rise, or amount of temperature rise above ambient condition. Spot type heat detectors should be selected so that the rating is at least 20°F (11°C) above maximum expected ceiling temperature. Ceiling height, construction, and ventilation play significant roles in detector performance and must be considered when determining detector placement. E-HD Fixed-Temperature/Rate of Rise Heat Detector The table below lists six standard types of fire and the suitability of the E-HD for each. The E-HD contains a 135°F (57°C) fixed-temperature heat sensor and a 15°F (8°C) per minute rate-of-rise heat sensor, which are best suited to detect fast, flaming fires such as open wood and liquid fires without smoke. E-HD applications Type of fire Suitability of E-HD Open wood Optimal Wood pyrolysis Unsuitable Smoldering cotton Unsuitable PU foam Suitable n-Heptane Very suitable Liquid fire without smoke Optimal Spacing of heat detectors Spot type heat detector spacing ratings are based on detector installation on a flat, smooth ceiling that is 10 feet (3 m) high. The listed spacing equates detector operation with the opening of a standard sprinkler head within 2 minutes (+/- 10 seconds) located 10 feet (3 m) from the same fire. Spot type detector spacing is Smoke, Heat, and Duct Detectors Application Bulletin 3 Heat detector applications shown in the figure below. Detector coverage is typically represented as a square because most structures have flat sidewalls. Actual detector coverage is a circle whose radius is 0.7 times the listed spacing. Since all of the area within the detector’s circle of coverage is suitable for detecting a fire, the shape and dimensions of the detector coverage “square” in the figure below may be modified.
Recommended publications
  • How to Live with Your Fire Alarm System
    How to Live with Your Fire Alarm System: Smoke detectors are sensitive to a number of items in addition to smoke from fire, including dusts and mists. To prevent nuisance fire alarms: 1. Do not smoke in your residence hall. 2. Do not spray aerosol products (air fresheners, hair spray, spray paint, perfume, mists, insect spray) or use candles, incense, powder, etc.) near smoke detectors or in large amounts. Consider using solid, non-aerosol air fresheners and keep spray paint and dusty projects outdoors in a well ventilated area. 3. Do not spray liquids on or near smoke detectors (cleaning products, water, steam) 4. Do not leave your microwave unattended. Burned food can smoke and does set off smoke detectors. Follow reheating directions and food preparation recommended cooking times, especially popcorn, and stay close by. 5. Do not use prohibited items such as candles, toaster ovens, George Forman Grills, or space heaters in your room. These items can cause nuisance fire alarms or worse - start a fire. Nuisance fire alarms and unnecessary fire department runs are dangerous, expensive, and disruptive for the fire department and create safety hazards for everyone. Your life and the lives of others may depend on your smoke detector. Do not disable or cover it. For more about cooking fires and fire prevention tips, visit NFPA.org @ http://www.nfpa.org/index.asp Fire Prevention Week commemorates the Great Chicago Fire of 1871, the tragic conflagration that killed more than 250 people, left 100,000 homeless, and destroyed more than 17,400 structures. Fire Prevention Week Web site www.firepreventionweek.org .
    [Show full text]
  • Smoke Alarms in US Home Fires Marty Ahrens February 2021
    Smoke Alarms in US Home Fires Marty Ahrens February 2021 Copyright © 2021 National Fire Protection Association® (NFPA®) Key Findings Smoke alarms were present in three-quarters (74 percent) of the injuries from fires in homes with smoke alarms occurred in properties reported homei fires in 2014–2018. Almost three out of five home with battery-powered alarms. When present, hardwired smoke alarms fire deathsii were caused by fires in properties with no smoke alarms operated in 94 percent of the fires considered large enough to trigger a (41 percent) or smoke alarms that failed to operate (16 percent). smoke alarm. Battery-powered alarms operated 82 percent of the time. Missing or non-functional power sources, including missing or The death rate per 1,000 home structure fires is 55 percent lower in disconnected batteries, dead batteries, and disconnected hardwired homes with working smoke alarms than in homes with no alarms or alarms or other AC power issues, were the most common factors alarms that fail to operate. when smoke alarms failed to operate. Of the fire fatalities that occurred in homes with working smoke Compared to reported home fires with no smoke alarms or automatic alarms, 22 percent of those killed were alerted by the device but extinguishing systems (AES) present, the death rate per 1,000 reported failed to respond, while 11 percent were not alerted by the operating fires was as follows: alarm. • 35 percent lower when battery-powered smoke alarms were People who were fatally injured in home fires with working smoke present, but AES was not, alarms were more likely to have been in the area of origin and • 51 percent lower when smoke alarms with any power source involved in the ignition, to have a disability, to be at least 65 years were present but AES was not, old, to have acted irrationally, or to have tried to fight the fire themselves.
    [Show full text]
  • Fire Service Features of Buildings and Fire Protection Systems
    Fire Service Features of Buildings and Fire Protection Systems OSHA 3256-09R 2015 Occupational Safety and Health Act of 1970 “To assure safe and healthful working conditions for working men and women; by authorizing enforcement of the standards developed under the Act; by assisting and encouraging the States in their efforts to assure safe and healthful working conditions; by providing for research, information, education, and training in the field of occupational safety and health.” This publication provides a general overview of a particular standards- related topic. This publication does not alter or determine compliance responsibilities which are set forth in OSHA standards and the Occupational Safety and Health Act. Moreover, because interpretations and enforcement policy may change over time, for additional guidance on OSHA compliance requirements the reader should consult current administrative interpretations and decisions by the Occupational Safety and Health Review Commission and the courts. Material contained in this publication is in the public domain and may be reproduced, fully or partially, without permission. Source credit is requested but not required. This information will be made available to sensory-impaired individuals upon request. Voice phone: (202) 693-1999; teletypewriter (TTY) number: 1-877-889-5627. This guidance document is not a standard or regulation, and it creates no new legal obligations. It contains recommendations as well as descriptions of mandatory safety and health standards. The recommendations are advisory in nature, informational in content, and are intended to assist employers in providing a safe and healthful workplace. The Occupational Safety and Health Act requires employers to comply with safety and health standards and regulations promulgated by OSHA or by a state with an OSHA-approved state plan.
    [Show full text]
  • DS Series Addressable Detector Application Guide K-76-1000
    w w DS Series Addressable Detector Application Guide K-76-1000 K-73-200 Rev AB July 2015 FOREWORD July 2016 -1- K-76-1000 PURPOSE OF THIS GUIDE This guide, K-76-1000, is to be used by qualified and factory-trained personnel, knowledgeable of NFPA standards and any other applicable standards in effect. This guide is intended to provide guidance to qualified technical professionals for the installation and maintenance of the DS Series Addressable Detectors. Any questions concerning the information presented in this guide should be addressed to: Kidde-Fenwal, Inc. 400 Main Street Ashland, MA 01721, USA Phone: (508) 881-2000 Toll Free: (800) 872-6527 Technical Support: (866) 287-2531 Fax: (508) 881-8920 www.kiddefiresystems.com LIMITATION OF LIABILITY Only qualified persons experienced and trained in the installation of this type of equipment should install and configure DS Series Addressable Detectors. Installation in accordance with this guide, applicable codes, and the instructions of the Authority Having Jurisdiction is mandatory. The technical data contained herein is provided for informational purposes only, and should not be used as a substitute for professional judgment. The content of this manual is proprietary in nature and is intended solely for distribution to authorized persons, companies, distributors or others for the sole purpose of conducting business associated with Kidde-Fenwal, Inc. Although, Kidde-Fenwal, Inc. believes this information to be true and correct, it is published and presented without any guarantee or warranty whatsoever. Kidde-Fenwal, Inc. disclaims any liability for any use of the data other than as set out in this manual, foreword included.
    [Show full text]
  • Emergency Management: Smoke Detectors & Fire Extinguishers
    s SMOKE DETECTORS es dn re and pa re P 7 FIRE EXTINGUISHERS Taking it one step Ever Vigilant Sentries That May at a time. SAVE YOUR LIFE Half of the home fires and three-fifths of fire deaths occur in homes without smoke detectors. Hundreds of people die each year in homes with smoke detectors that don’t work. It’s important that you not only have a smoke detector, but that you check and maintain it frequently. You Need To Know What Kind Important Information Of Smoke Detector You Have & About Smoke Detectors How To Maintain It •Battery-Powered Make Placement a Priority Battery-powered smoke detectors operate on •At a minimum, there should be a smoke alkaline batteries. Unlike the bunny, they won’t detector in the hallways and corridors keep going forever. The battery should be checked between the sleeping areas and the rest of weekly and replaced twice a year. A good time to the house, and/or a smoke detector in the do this is when you change your clock in the fall and center of the ceiling directly above each spring. stairway. •Hard-Wired without Battery Back-up • Additional measures include installing smoke This type of smoke detector operates on household detectors on a wall or the ceiling in each current. As long as you have electricity, it will sleeping room. function; but if your house loses power, it will no • Because smoke rises, smoke detectors longer function. If you have this type, you should should be mounted high on the wall or also install battery-operated models for back-up.
    [Show full text]
  • Life Safety Dampers Selection and Application Manual • Ceiling Radiation Dampers • Fire Dampers • Combination Fire Smoke Dampers • Smoke Dampers
    Life Safety Dampers Selection and Application Manual • Ceiling Radiation Dampers • Fire Dampers • Combination Fire Smoke Dampers • Smoke Dampers August 2016 1 Table of Contents HOW TO USE THIS MANUAL DAMPER APPLICATION 3 • Fire Damper Application • Smoke Damper Application • Combination Fire Smoke Damper Application • Corridor Ceiling Combination Fire Smoke Damper Application DAMPER SELECTION 5 • Selection Process • Key Points to Remember ACTUATOR SELECTION 7 • Selection Process • Actuator Mounting Options • Key Points to Remember SLEEVE REQUIREMENTS 9 • Sleeve Thickness • Sleeve Length • Key Points to Remember SPACE REQUIREMENTS FOR PROPER INSTALLATION 10 • Key Points to Remember DAMPER OPTIONS 11 • Control Options • Security Bar Options • Transition Options • Key Points to Remember INSTALLATION REQUIREMENTS 15 • Combination Fire Smoke Damper Installation • Smoke Damper Installation • Actuator Installation • Damper and Actuator Maintenance • Key Points to Remember SPECIAL INSTALLATION CASES 17 • Maximum Damper Size Limitations • Horizontal Fire Smoke Damper in a Non-Concrete Barrier • AMCA Mullion System • What if a Damper Cannot be Installed per the Manufacturer’s Installation Instructions? • What if a Damper Cannot be Installed in the Wall? • Steps to Take When an Unapproved Installation Must be Provided CEILING RADIATION DAMPERS 20 • Ceiling Radiation Damper Application • Key Points to Remember CODES AND STANDARDS 21 • Compliance with the Applicable Building Codes • The National Fire Protection Association • Code and Standard Making
    [Show full text]
  • Requirements for Certificate of Smoke Detector, Carbon Monoxide and Fire Extinguisher Compliance
    REQUIREMENTS FOR CERTIFICATE OF SMOKE DETECTOR, CARBON MONOXIDE AND FIRE EXTINGUISHER COMPLIANCE Per New Jersey Statutes, the seller is responsible for this test unless otherwise provided. This certificate is required and applies to any structure used or intended for use for residential purposes by not more than two households, or the structure is rented, sold or otherwise made subject to a change of occupancy BEFORE such change takes place. REQUIREMENTS A smoke detector is required on every level of the home. On the levels where there are bedrooms, in addition to a smoke detector, you are required to have a carbon monoxide detector**. Battery powered or electric dual units- (both smoke and carbon monoxide in one housing) 10 year sealed units are required. If you have a basement or crawl space over four (4) feet high, or an attic which has a permanent staircase (not a pull down type) it is considered a level and must have a smoke detector. Portable fire extinguisher: One (1) 2A10BC portable fire extinguisher; 5 pounds to 10 pounds, rated minimum: 2-A:10-B:C is required. It is important to note the extinguisher MUST carry the ABC rating, not just B-C. MOUNTING Smoke detectors and carbon monoxide alarm(s) are required to be mounted outside the bedroom(s), within ten (10) feet of the bedroom door. Battery powered detectors are acceptable. Smoke detectors*: shall be mounted (screwed) to the ceiling or wall. If you choose to mount the smoke detector on the wall, follow the manufacturer’s instructions. In no case shall the top edge of the detector be less than four (4) nor more than twelve (12) inches from the ceiling.
    [Show full text]
  • Conventional Smoke & Heat Detectors Mir-65 Series
    CONVENTIONAL SMOKE & HEAT DETECTORS MIR-65 SERIES Features • Wide operating voltage range • Advanced electronics technology • Flashing standby/steady alarm LED • Magnetic test switch • Low profi le (1 5/8”H x 4”Dia.) MPD-65P Photoelectric Smoke Detector • Can be used on security systems • Locking feature reduces tampering • Designed to meet approvals worldwide • Large range of bases available • Separate head/base design allows interchangeability and ease of installation • High RF, noise and insect immunity • Available in 2 and 4 Wire Kits MHD-65-135 Heat Detector MID-65I Ionization Smoke Detector Description The MIR-65 Series incorporate proven sensing Fixed and Rate-of-Rise Heat Detector Head technologies, together with advances in materials and (MHD-65-135/MHD-65-200) electronics technology. Having a wide operating voltage The heat detector operates by using a matched pair of of 9-33VDC, the MIR-65 Series detectors can be thermistors to sense heat. One thermistor is exposed integrated into most Fire/Security systems. The MIR-65 to the ambient temperature, the other is sealed. In Series wide voltage range family consists of photoelectric normal conditions the two thermistors register similar smoke, ionization smoke, and heat detectors. temperatures; but, on the development of a fi re, the Ionization Smoke Detector Head (MID-65I) temperature recorded by the exposed thermistor The sensing part of the ionization detector consists of will increase rapidly, resulting in an imbalance that two chambers - an open outer chamber with a second causes the detector to change into the alarm state. semi-sealed reference chamber within. Mounted in the Rate-of-rise detectors are designed to detect a fi re as reference chamber is a low activity radioactive foil of the temperature increases, but they also have a fi xed Americium 241 which enables current to fl ow between the upper limit at which the detector will go into alarm if inner and outer chambers when the detector is powered the rate of temperature increase has been too slow to up.
    [Show full text]
  • Smoke Detectors Carry a Small Amount of a Radioactive Isotope Called Americum 241
    CITY AND COUNTY OF DENVER Department of Safety Fire Department Fire Prevention Division P.O. Box 40385 Denver, CO 80204 p: 720.913.3474 f: 720.913.3587 Residential Fire Safety Maintaining and Using Single- and Multiple-station Smoke Alarms, Carbon Monoxide Alarms, Combination Carbon Monoxide and Smoke Alarms, and Fire Extinguishers described below. It’s easy to forget that a smoke alarm’s sole In 2009, the State of Colorado and City and County of function is to sound the warning. Develop and practice an Denver passed ordinances requiring Carbon Monoxide escape plan so that if the alarm sounds, your family can get out (CO) alarms in residences—a new facet added to quickly. governmental requirements for home safety. Requirements and Positioning: This document will tell you how to make sure you’re in compliance with existing requirements for smoke • Smoke alarms are required in every residential dwelling or sleeping unit, including single-family homes. alarms and fire extinguishers, what you need to do to • Every multi-family residential facility is required to have comply with the new CO detector requirements, and smoke alarms, whether battery-operated or hard-wired with best practices for home fire safety. battery backup. • Smoke alarms are required in every bedroom, outside each Background sleeping area, and on every level of the home including the basement. In 2016 there were 1,342,000 fires reported in the United States. These fires caused 3,390 civilian deaths, 14,650 Maintenance – Smoke Alarms: civilian injuries, and $10.6 billion in property damage. (NFPA) Kitchens are the leading area of origin for these fires.
    [Show full text]
  • Supplement 2
    SUPPLEMENT 2 Fire Alarm Systems for Life Safety Code Users Robert P. Schifiliti, P.E. Editor’s Note: This supplement is an introduction to fire alarm systems. It explains the various types of systems addressed by the Life Safety Code and describes their components in detail. In this supplement the term fire alarm is intended to include detection systems and systems that provide control functions, such as elevator recall, and alarm information or notification to occupants and emergency forces. Robert P. Schifiliti is the founder of R.P. Schifiliti Associates, Inc., and is chair of the Technical Committee on Notification Appliances for Fire Alarms Systems. Mr. Schifiliti serves as one of several faculty for the NFPA Fire Alarm Workshop and is a licensed fire protection engineer. He received the degree of master of science in fire protection engineering from Worcester Polytechnic Institute. INTRODUCTION cept of Mass Notification Systems used for emer- gency communication and management. This supplement starts with an overview that de- Specific requirements and designs for various oc- scribes how NFPA codes and standards categorize cupancies are not discussed in this supplement. The the various types of fire detection and alarm systems. occupancy chapters of the Life Safety Code should be A section on fire signatures reviews the sensible or consulted for specific requirements. The additional detectable physical and environmental changes that commentary contained in other chapters of this hand- take place during a fire. A review of fire detection book provides a good explanation of the require- devices emphasizes proper selection in order to meet ments and the philosophy behind their intent.
    [Show full text]
  • Smoke & Carbon Monoxide Detector Requirement
    A Guide to the Massachusetts… Smoke & Carbon Monoxide Requirements …when Selling a One- or Two-Family Residence -!33 4-%. 0!2 4/ $% & RE SERVICE Department of Fire Services FI S # % - . % 3 S 4 % % 0 O ) T % 6 4 1 ) T 4 M % 4 E PO BOx 1025 • StOw, MA 01775 • 978-567-3300 ! 0 4 , 2 ! M # % " S ) $ ) ! , - 3 6 " U O H F C A - S AS www.mass.gov/dfs M.G.L. C 148 S. 26F - THE LAW Massachusetts General Law, chapter 148 section 26F mandates that upon the sale or transfer of certain homes, the seller must install approved smoke detectors. These requirements apply to residences that were built or modified prior to creation of the Massachusetts State Building Code (January 1, 1975). If a building has undergone renovation, addition or modification after Jan. 1, 1975, the date of the building permit determines the smoke detector requirements of the building code. Although the transfer law applies to residences with five or less residential units, this pamphlet will focus only on one- and two-family homes. VERIFICATION After a successful inspection for smoke detector compliance, the local fire department will issue a Certificate of Compliance indicating that the residence meets the smoke detector requirements. Although the law applies to homes built prior to the date of the building code (Jan. 1975), it is industry practice that most purchase and sales agreements, and many mortgage companies require that the seller, as a condition to sell or transfer, obtain a Certificate of Compliance issued by the local fire department, even if the home was permitted or modified after 1975.
    [Show full text]
  • Smoke Alarms and Fire Safety
    OHIO BOARD OF BUILDING STANDARDS Smoke Alarms and Fire Safety Updated January 2016 2 UNDERSTANDING THE TERMINOLOGY Detector. An initiation device suitable for connection to a circuit that has a sensor that responds to a physical stimulus such as heat or smoke. Examples of Detector Types: Air Sampling Automatic Fire Combination Electrical Conductivity Fire-Gas Heat Flame Fixed-Temperature Projected Beam Rate Compensation Rate-of-Rise Radiant Energy Sensing Spark/Ember Spot-Type Household fire alarm system. A system of devices that uses a fire alarm control unit to produce an alarm signal in the household for the purpose of notifying the occupants of the presence of a fire so that they will evacuate the premises. Multiple Station Alarm Device. Two or more single station alarm devices that can be interconnected so that actuation of one causes all integral or separate audible alarms to operate; or one single station alarm device having connections to other detectors or to a manual fire alarm box. Nuisance Alarm. An alarm caused by mechanical failure, malfunction, improper installation, or lack of proper maintenance, or an alarm activated by a cause that cannot be determined. Single Station Alarm Device. An assembly that incorporates the detector, the control equipment, and an alarm-sounding device in one unit operated from a power supply either located in the unit or obtained at the point of installation. Smoke Alarm. A single or multiple station alarm device responsive to smoke. Often, individuals use the terms “smoke alarm” and “smoke detector” interchangeably. While a common practice, these terms describe very different systems and should not be used as synonyms.
    [Show full text]