City of Glendale Fire Department

Total Page:16

File Type:pdf, Size:1020Kb

City of Glendale Fire Department CITY OF GLENDALE FIRE DEPARTMENT FIRE STATION NO. 28 RENOVATION GLENDALE, CALIFORNIA PROJECT MANUAL CONSTRUCTION DOCUMENTS PROJECT #: 17052.01 MAY 10, 2019 BLANK PAGE City of Glendale Fire Department Project #17052.01 Fire Station No. 28 Renovation Construction Documents TABLE OF CONTENTS DIVISION 1 - GENERAL REQUIREMENTS 01 10 00 Summary 01 23 00 Alternates 01 26 00 Contract Modification Procedures 01 29 00 Payment Procedures 01 31 00 Project Management and Coordination 01 32 00 Construction Progress Documentation 01 33 00 Submittal Procedures 01 40 00 Quality Requirements 01 42 00 References 01 45 23 Testing & Inspection 01 50 00 Temporary Facilities and Controls 01 60 00 Product Requirements 01 73 00 Execution Requirements 01 73 29 Cutting and Patching 01 74 19 Construction Waste management 01 77 00 Closeout Procedures 01 78 23 Operation and Maintenance Data 01 78 39 Project Record Documents 01 79 00 Demonstration and Training 01 81 19 Construction Indoor Air Quality 01 81 23 Noise and Vibration Control DIVISION 2 – EXISTING CONDITIONS 02 41 00 Demolition PMSM DIVISION 3 - CONCRETE 03 10 00 Concrete Formwork SWA 03 20 00 Reinforcing Steel SWA 03 30 00 Cast-In-Place Concrete SWA DIVISION 4 – MASONRY DIVISION 5 - METALS 05 12 00 Structural Steel SWA 05 40 00 Cold-Formed Metal Framing SWA TABLE OF CONTENTS 1 City of Glendale Fire Department Project #17052.01 Fire Station No. 28 Renovation Construction Documents DIVISION 6 – WOOD, PLASTICS, AND COMPOSITES 06 10 00 Rough Carpentry SWA 06 16 43 Gypsum Sheathing PMSM 06 20 00 Finish Carpentry PMSM 06 41 00 Architectural Wood Casework PMSM DIVISION 7 - THERMAL AND MOISTURE PROTECTION 07 21 00 Thermal Insulation PMSM 07 27 00 Air Barrier PMSM 07 42 13 Metal Screen Wall PMSM 07 51 13 Cold Process Built-Up Asphalt Roofing System PMSM 07 62 00 Sheet Metal Flashing and Trim PMSM 07 84 00 Fire Stopping PMSM 07 92 05 Joint Sealers PMSM DIVISION 8 - OPENINGS 08 11 13 Hollow Metal Doors and Frames PMSM 08 14 29 Prefinished Wood Doors PMSM 08 14 76 Bifolding Wood Doors PMSM 08 51 13 Aluminum Windows PMSM 08 71 00 Door Hardware ALLEGION 08 80 00 Glazing PMSM DIVISION 9 – FINISHES 09 05 61 Common Work Results for Flooring Preparation PMSM 09 21 16 Gypsum Board Assemblies PMSM 09 22 00 Supports for Plaster and Gypsum Board PMSM 09 24 00 Portland Cement Plaster PMSM 09 30 00 Tiling PMSM 09 65 13 Resilient Flooring Base PMSM 09 68 13 Carpet Tile PMSM 09 91 00 Painting and Coating PMSM DIVISION 10 – SPECIALTIES 10 14 24 Signage PMSM 10 28 00 Toilet Accessories PMSM DIVISION 11 – EQUIPMENT DIVISION 12 – FURNISHINGS 12 36 60 Countertops PMSM TABLE OF CONTENTS 2 City of Glendale Fire Department Project #17052.01 Fire Station No. 28 Renovation Construction Documents DIVISION 21 – FIRE SUPPRESSION 21 05 00 Common Work Results for Fire Protection GM 21 13 13 Wet Pipe Sprinkler Systems GM DIVISION 22 – PLUMBING 22 05 00 Common Work Results for Plumbing GM 22 05 19 Meters and Gages for Plumbing Piping GM 22 05 23 General Duty Valves for Plumbing Piping GM 22 05 29 Hangers and Supports for Plumbing Piping and Equipment GM 22 05 48 Vibration Controls for Plumbing Piping and Equipment GM 22 05 53 Identification for Plumbing Piping and Equipment GM 22 07 00 Plumbing Insulation GM 22 11 16 Domestic Water Piping GM 22 11 19 Domestic Water Piping Specialties GM 22 13 16 Sanitary Waste and Vent Piping GM 22 13 19 Sanitary Waste Piping Specialties GM 22 34 00 Fuel-Fired Domestic Water Heaters GM 22 40 00 Plumbing Fixtures GM 22 47 00 Drinking Fountains and Water Coolers GM DIVISION 23 – HEATING VENTILATING AND AIR CONDITIONING 23 05 00 Common Work Results for HVAC GM 23 05 13 Common Motor Requirements for HVAC Equipment GM 23 05 29 Hangers and Supports for HVAC Piping and Equipment GM 23 05 48 Vibration Controls for HVAC Piping and Equipment GM 23 05 53 Identification for HVAC Piping and Equipment GM 23 05 93 Testing, Adjusting and Balancing for HVAC GM 23 07 00 HVAC Insulation GM 23 11 23 Natural Gas Piping GM 23 23 00 Refrigerant Piping GM 23 31 13 Metal Ducts GM 23 33 00 Air Duct Accessories GM 23 34 43 Ceiling Fans GM 23 37 13 Grilles, Registers and Diffusers GM 23 81 26 Split System Air Conditioners GM DIVISION 26 – ELECTRICAL 26 05 00 Common Work Results for Electrical GM 26 05 19 Low-Voltage Electrical Power Conductors and Cables GM 26 05 26 Grounding and Bonding for Electrical Systems GM 26 05 29 Hangers and Supports for Electrical Systems GM 26 05 33 Raceway and Boxes for Electrical Systems GM 26 24 16 Panelboards GM 26 27 26 Wiring Devices GM 26 51 00 Interior Lighting GM DIVISION 27 – COMMUNICATIONS TABLE OF CONTENTS 3 City of Glendale Fire Department Project #17052.01 Fire Station No. 28 Renovation Construction Documents DIVISION 28 – ELECTRONIC SAFETY AND SECURITY DIVISION 31 – EARTHWORK DIVISION 32 – EXTERIOR IMPROVEMENTS 32 17 23 Pavement Markings PMSM DIVISION 33 – UTILITIES EXHIBIT A Test Report: Asbestos Analysis of Bulk Materials – Fire Station 28 LA Testing Test Report: Lead in Paint Chips – Fire Station 28 LA Testing END OF TABLE OF CONTENTS TABLE OF CONTENTS 4 City of Glendale Fire Department Project #17052.01 Fire Station No. 28 Renovation Construction Documents SECTION 01 10 00 SUMMARY PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 1 Specification Sections, apply to this Section. 1.2 SUMMARY A. This Section includes the following: 1. Work covered by the Contract Documents. 2. Type of the Contract. 3. Work phases. 4. Use of premises. 5. Owner's occupancy requirements. 6. Work restrictions. 7. Specification formats and conventions. 8. Deferred Approvals. 9. Pollution Control. 10. Storm Water Pollution Prevention Plan. 11. Lead-Containing materials. 12. Additional DSA requirements. 1.3 SUBMITTALS A. Contractor shall submit written statement of responsibility per CBC 1706A.1 B. R & B Schultz Early Childhood Education Building 1.4 WORK COVERED BY CONTRACT DOCUMENTS A. Project Identification: City of Glendale Fire Department Fire Station 28 Renovation 1. Project Location: 4410 New York Ave, Glendale, CA 91214 B. Owner: City of Glendale C. Architect: PMSM. D. The Work consists of the following: 1. The Work includes exterior and interior renovations to building residential and work areas. The work is inclusive of architectural, structural and mechanical renovations. SUMMARY 01 10 00 - 1 City of Glendale Fire Department Project #17052.01 Fire Station No. 28 Renovation Construction Documents 2. The intent of these drawings and specifications is that the alteration, rehabilitation or reconstruction is to be in accordance with Title 24, California Code of Regulations. Should any existing conditions such as deterioration or non-complying construction be discovered which is not covered by the contract documents wherein the finished work will not comply with Title 24, California Code of Regulations, a Construction Change Document, or a separate set of plans and specifications, detailing and specifying the required repair work shall be submitted to and approved by the City of Glendale before proceeding with the repair work. 1.5 TYPE OF CONTRACT A. Project will be constructed under a single prime contract. 1.6 WORK PHASES A. The Work shall be conducted in single phase. 1.7 USE OF PREMISES A. General: Contractor shall have limited use of premises for construction operations as indicated on Drawings by the Contract limits. B. Use of Site: Limit use of premises to work in areas indicated. Do not disturb portions of Project site beyond areas in which the Work is indicated. 1. Owner Occupancy: Allow for Owner occupancy of Project site and use by the public. 2. Driveways and Entrances: Keep driveways and entrances serving premises clear and available to Owner, Owner's employees, and emergency vehicles at all times. Do not use these areas for parking or storage of materials. a. Schedule deliveries to minimize use of driveways and entrances. b. Schedule deliveries to minimize space and time requirements for storage of materials and equipment on-site. 1.8 OWNER'S OCCUPANCY REQUIREMENTS A. Full Owner Occupancy: Owner will occupy site and existing building during entire construction period. Cooperate with Owner during construction operations to minimize conflicts and facilitate Owner usage. Perform the Work so as not to interfere with Owner's day-to-day operations. Maintain existing exits, unless otherwise indicated. 1. Maintain access to existing walkways, corridors, and other adjacent occupied or used facilities. Do not close or obstruct walkways, corridors, or other occupied or used facilities without written permission from Owner and authorities having jurisdiction. 2. Provide not less than 72 hours' notice to Owner of activities that will affect Owner's operations. B. Owner Occupancy of Completed Areas of Construction: Owner reserves the right to occupy and to place and install equipment in completed areas of building, before Substantial Completion, SUMMARY 01 10 00 - 2 City of Glendale Fire Department Project #17052.01 Fire Station No. 28 Renovation Construction Documents provided such occupancy does not interfere with completion of the Work. Such placement of equipment and partial occupancy shall not constitute acceptance of the total Work. 1. Architect will prepare a Certificate of Substantial Completion for each specific portion of the Work to be occupied before Owner occupancy. 2. Obtain a Certificate of Occupancy from authorities having jurisdiction before Owner occupancy. 3. Before partial Owner occupancy, mechanical and electrical systems shall be fully operational, and required tests and inspections shall be successfully completed.
Recommended publications
  • STANDING SEAM System Technology for Roofing
    STANDING SEAM System Technology for Roofing DESIGN AND APPLICATION STANDING SEAM, DESIGN AND APPLICATION Residence in Capetown, South Africa Mormon Temple, Tucson, AZ Geschäftshaus Wensler, New Church, Germany Standing Seam Roof System 1. This system may be fabricated from the 5. For cost effectiveness, ease of fab- 9. To determine whether a ventilation mat following PRODUCT LINES: rication and installation, limit panel and/or factory applied ProRoofi ng lengths to 40’, although the maximum backside coating is required for allowable length of 52’ is possible. RHEINZINK standing seam roofi ng CLASSIC Consult the RHEINZINK technical panels, please refer to the RHEINZINK department for applications requiring Steep Slope, Mid Slope and Low Slope longer lengths. Roofi ng recommendations. PRISMO 6. It is recommended to single lock the 10. All roof installations require Air-Z or panels every 3’-4’ prior to seaming to Enkamat (7008 or 7010). 2. Easy to fabricate and install. assure proper seam closure. 11. Roof penetrations such as skylights, 3. Panel widths from 12” to 24”. 7. Refer to the RHEINZINK baseline chimneys or vents that interrupt the details for detail options for eaves, seams constitute the most vulnerable 4. For optimum fl atness: rakes, hips, ridges, valleys and pen- part of any standing seam roof. These Use 0.8 mm thick RHEINZINK for etrations. Consult the RHEINZINK areas must be carefully detailed fully panel widths 17” to 24”. technical department for customized with apron fl ashings with suffi cient Use 0.7 mm thick RHEINZINK for applications. overlap lengths, capillary breaks, and panel heights 12” to 17”.
    [Show full text]
  • Marine Catalog 0813.Indd
    COMPLETE FACILITY PROTECTION MARINE CATALOG MARINE CATALOG MARINE CATALOG CONTENTS P6 EASY MASK PRODUCTS P11 FLOORING & PROTECTIVE ROLLS P15 DROPCLOTHS P19 RAGS, TOWELS & WIPERS P24 PAINT STRAINERS P26 GLOVES P28 PROTECTIVE WEAR P32 MISCELLANEOUS SUNDRIES P34 CLEANING & PAINT PREP PRODUCTS P37 PRODUCT INDEX P38 TERMS & CONDITIONS EASY MASK® PRODUCTS Our Easy Mask line offers tools for the quick and easy way to mask off window and door trim to prep for painting. Gorgeous paint jobs begin with Easy Mask! PAINTING TAPE KleenEdge® Painting Tape Traditional Easy Mask kraft paper tape with an uncoated portion to catch spills. Quick, easy to apply and remove and is designed for use on a variety of surfaces. Can be left on for 7 days. ITEM # UPC PACK SIZE 642160 KleenEdge Painting Tape 0-47034-64216-5 12 2" x50' blister card 706060 KleenEdge Painting Tape 0-47034-70606-5 12 2" x180' 683160 KleenEdge Painting Tape 0-47034-68316-8 12 3 3/4" x75' 329400 KleenEdge Painting Tape 0-47034-32940-0 12 3" x180' 329410 KleenEdge Painting Tape 0-47034-32941-7 12 6" x180' 329040 KleenEdge Painting Tape 0-47034-32904-2 6 9" x180' 329480 KleenEdge Painting Tape 0-47034-32948-6 6 12" x180' KleenEdge® Low Tack™ Painting Tape Flat white paper tape specially designed for use on delicate surfaces. Leaves clean straight lines and can be left on for 14 days. ITEM # UPC PACK SIZE 591260 KleenEdge Low Tack Painting Tape 0-47034-59126-5 24 24mm x50m (Use as 1") 591360 KleenEdge Low Tack Painting Tape 0-47034-59036-4 12 36mm x50m (Use as 1 1/2") 591460 KleenEdge Low Tack Painting Tape 0-47034-59146-3 12 48mm x50m (Use as 2") KleenEdge® Perfect Edge™ Painting Tape Flat blue paper tape specially designed for use on a variety of surfaces.
    [Show full text]
  • 01142015 OHIO MAS Roofing
    TREMCO CY '15 OHIO MAS PRICELIST Date Submitted: 3/5/2010 Updated:1/5/2015 LINE ITEM # Description Price Per Ohio Net (1/5/2015) Price (1/5/2015) 3.1 Water resistant roofing 3.1.1.1 Pressure cleaning, vertical walls SF$ 0.19 3.1.1.2 Pressure cleaning, horizontal surfaces SF$ 0.37 3.1.2 Asphalt emulsion coating waterproofing, brush applied, per coat SF$ 0.40 3.1.3 Rubberized coating waterproofing, brush applied, per coat SF$ 0.47 3.1.4 Vinyl/acrylic resin, dampproofing, brush applied per coat. SF$ 0.77 3.1.5 Non-pigmented synthetic resin, waterproofing, one coat sprayed on SF$ 0.42 3.1.6 Caulking: remove existing, clean and prime joint LF$ 1.06 3.1.7 Caulking, epoxied urethane compound, 2 component, 1/4” x 1/4”, in place LF$ 1.16 3.1.8 Caulking, polyurethane, 1 component, 1/4” x 1/4”, in place LF$ 1.24 3.1.9 Caulking, polyurethane, 1 component, 1/2” x 1/2”, in place LF$ 2.63 3.1.10 Caulking, silicone rubber, 1 component, 1/4” x 1/4”, in place LF$ 1.02 3.1.11 Caulking, epoxied urethane compound, 2 component, 3/4” x 3/8”, in place LF$ 2.10 3.1.12 Caulking, silicone rubber, 1 component, 3/4” x 3/8”, in place LF$ 1.45 3.1.13 Backer rod, polyethylene, 3/8” diameter, installed in prepared opening LF$ 0.24 3.1.14 Backer rod, polyethylene, 1/2” diameter, installed in prepared opening LF$ 0.39 3.1.15 Backer rod, polyethylene, 3/4” diameter, installed in prepared opening LF$ 0.42 3.1.16 Backer rod, polyethylene, 1” diameter, installed in prepared opening LF$ 0.48 3.1.17 Route existing cracks in concrete or masonry LF$ 0.77 3.1.18 Prepare concrete
    [Show full text]
  • Product Catalog COMPANY HISTORY
    Product Catalog COMPANY HISTORY TRIMACO, LLC Trimaco, LLC was created in March, 2003 when the following three companies merged operations: D. C. May Corporation, Durham, NC A major paint sundry manufacturer. Founded in 1906, D.C. May was the largest paint contractor operation in the southeastern U.S. before it began making its own dropcloths and sundries. Charter member of the Carolinas PDCA. Tufpro - Paint Sundries Division of TufcoTechnologies, St. Louis, MO A whole line manufacturer and supplier of the Tufpro brand of dropcloths and paint sundries. Tri Paper, Phoenix, AZ A major manufacturer of red rosin paper, builder’s paper, and masking paper. The combined operation brings to the market the best of the three companies: exceptional customer service, high-quality products, fair pricing and bi-coastal distribution centers. Trimaco, LLC offers the most complete paint sundry product line to the professional paint store, hardware, home center, retail, automotive and marine industries. COMPANY GOALS OUR STRATEGY · To provide high-quality, professional and consumer products that meet and exceed all customer expectations. · To achieve exceptional levels of quality and service. · To add value to our core groups of customers - paint contractors, consumers and OEM accounts. · To never lose focus on our customers’ needs. · To constantly upgrade our office systems to make use of the latest technology. · To be our customer’s “one-stop” source for all protection and cleaning products. · To develop new and improved products to better serve our customers. OUR PURPOSE Trimaco offers protection to ensure paint is contained in areas meant to be painted. There is nothing that compares to a quality paint job, and our products help achieve this.
    [Show full text]
  • Waterlox Original Interior Tung Oil Finishing System
    Waterlox Original Interior Tung Oil Finishing System WHERE TO USE Beautiful. Natural. Durable. That’s a Waterlox Original Tung oil finished wood surface. A unique blend of Tung oil and resin, Waterlox showcases the natural beauty of wood, providing lasting, durable protection. This elegant, one-of-a-kind finish has been made by the Hawkins family since 1910, and is still made by hand according to the original family formula. The Waterlox Original Interior Tung oil finishing system is specially formulated for interior wood surfaces, including: • Hardwood floors • All interior woodwork, doors, walls, windowsills, beams, ceilings, etc. • Countertops, bars and table tops • Bathroom & kitchen vanities/cabinets • Furniture & fine woodworking • Various woodworking projects • Exterior wood ceilings (not in direct UV/sunlight) • NOT recommended for use outdoors in direct UV/sunlight1 The origin of our name, Waterlox, stands for "locks out water.” Therefore, we think our Waterlox Original Tung oil finishes are the perfect solution for any and all wood finishing project(s). When you add to that your plans to finish a floor or a known water-related area like a bathroom, kitchen, counter top or table top, we think Waterlox should be the only finishing choice since no other clear finishes, surface finishes or raw oils available on the market today have our superior protection and water resistance properties. Waterlox Original Tung oil finishes are tough enough to stand up to foot traffic and household spills, are water resistant and non-toxic2 and food-safe when dry. Waterlox Original Tung oil finishes have good heat resistance, can be used around stoves and are unaffected by boiling water and liquids.3 As with any finish, special care and attention should be used when applying the Waterlox Original Tung oil finishes.
    [Show full text]
  • Structural Properties of Wood-Frame Wall, Partition, Floor, and Roof Constructions with "Red Stripe" Lath Sponsored by the Weston Paper and Manufacturing Co
    i NATIONAL BUREAU OF STANDARDS The program of research on building materials and structures, carried on by the National Bureau of Standards, was undertaken with the assistance of the Central Hous- iug Committee, an informal organization of governmental agencies concerned with housing construction and finance, which is cooperating in the investigations through a subcommittee of principal technical assistants. CENTRAL HOUSING COMMITTEE SUBCOMMITTEE ON TECHNICAL RESEARCH Walter Junge, Chairman. A. C. Shire, Vice Chairman. Federal Housing Administration. United States Housing Authority. Sterling R. March, Secretary Albert G. Bear, George E. Knox, Veterans' Administration. Yards and Docks (Navy). Pierre Blouke, Vincent B. Phelan, Federal Home Loan Bank Board (Fed- National Bureau of Standards (Com- eral Loan Agency). Carroll W. Chamberlain, merce). Public Buildings Administration (Fed- Edward A. Poynton, eral Works Agency). Office of Indian Affairs (Interior). Joseph M. DallaValle, George W. Trayer, Public Health Service (Federal Security Forest Service (Agriculture), Agency). John Donovan, Elsmere J. Walters, Farm Security Administration (Agri- Construction Division (War). culture). CHAIRMEN OF SECTIONS Specifications Materials Maintenance Carroll W. Chamberlain Elsmere J. Walters John H. Schaefer Mechanical Equipment Methods and Practices Robert K. Thulman NATIONAL BUREAU OF STANDARDS STAFF COMMITTEE ON ADMINISTRATION AND COORDINATION Hugh L. Dryden, Chairman. Mechanics and Sound. Phaon H. Bates, Gustav E. F, Lundell, Clay and Silicate Products. Chemistry. Hobart C. Dickinson, Addams S. McAllister, Heat and Power. Codes and Specifications. Warren E. Emley, Henry S. Rawdon, Organic and Fibrous Materials. Metallurgy. The Forest Products Laboratory of the United States Department of Agriculture is cooperating with both committees on investigations of wood constructions. [For list of BMS publications and how to purchase, see cover page III.] UNITED STATES DEPARTMENT OF COMMERCE • Harry Hopkins, Secretary NATIONAL BUREAU OF STANDARDS • Lyman J.
    [Show full text]
  • Red Rosin Paper® Fernley, NV 89408 Utility Paper® Phoenixboard Builders Shim Stock® Company Contact: Technical Services Fortiboard™ Telephone Number: (800) 773-4777
    SAFETY DATA SHEET Page 1 of 4 Kraft Paper and Board Products 1. Product And Company Identification Supplier Product(s): Fortifiber Building Systems Group Scribe Rite® White 300 Industrial Drive Red Rosin Paper® Fernley, NV 89408 Utility Paper® Phoenixboard Builders Shim Stock® Company Contact: Technical Services FortiBoard™ Telephone Number: (800) 773-4777 Web Site: www.fortifiber.com Issue Date: 07/14/2017 Supersedes: 10/13/2015 Product Description Paper based building materials. 2. Hazards Identification In the solid state the material is not considered a hazardous material as defined by 21 CFR 1910.1200 (b) (6) (v). This product meets the definition of an “Article” and is not subject to the regulations of the Hazardous Products Act. However, cellulose dust is a regulated hazard when it becomes mechanically processed and airborne. Eye Hazards In the solid state it is not a probable route of exposure. Dust may mechanically irritate the eyes. Skin Hazards N/A. Ingestion Hazards N/A. Inhalation Hazards In the solid state it is not a probable route of exposure. Avoid breathing dust. Signs and Symptoms of Exposure None. Other Hazards Warning – If converted to small particles, may form combustible dust concentrations in air. 3. Composition/Information On Ingredients Ingredient CAS Percent Of Name Number Total Weight Cellulose 65996-61-4 >90 Aluminum Sulfate 10043-01-3 0-1 SAFETY DATA SHEET Page 2 of 4 Kraft Paper and Board Products 4. First Aid Measures Eye Treat dust in eye as foreign object. Flush with water to remove dust particles. Seek medical attention if irritation persists. Skin N/A.
    [Show full text]
  • Product Catalogue Catalog
    PRODUCTPRODUCT CATALOGUE CATALOG SUPPLYING JOBSITE CONFIDENCE SINCE www.trimaco.com | 800.325.7356 facebook.com/TrimacoINC twitter.com/TrimacoINC instagram.com/Trimaco_INC 1906 These are our top-selling products in the FEATURED PRODUCT paint and construction industries. Check out the new skus of these Trimaco products. NEW SKU! Don’t miss the many new and innovative NEW! items Trimaco has to offer. Trimaco offers several products that are made from recycled materials and/or are recyclable. 02 TRIMACO / SUPPLYING JOBSITE CONFIDENCE SINCE 1906 PRODUCT KEY CONTENTS 04 HEAVY DUTY SURFACE PROTECTION 08 PROTECTIVE FILMS 11 DROPCLOTHS 15 RAGS + WIPERS 19 PROTECTIVE WEAR 26 FLOORING PAPER 27 MASKING PAPER 28 MASKING PRODUCTS 31 MASKING TAPES 32 PAINT STRAINERS 34 GLOVES 35 MISCELLANEOUS SURFACE PROTECTION 37 DUST CONTAINMENT 38 MISCELLANEOUS PRODUCTS 41 ENVIROSOLUTIONS 42 PRODUCT INDEX CONTENTS TRIMACO.COM / +1 314 534 5005 / +1 800 325 7356 03 HEAVY DUTY SURFACE PROTECTION ® FLOORSHELL This heavy duty construction board features our innovative liquid repellent technology. Plus, the scored edge makes it simple to fold and protect skirting boards and walls. Strong enough for forklifts! ITEM No. UPC PACK PALLET SIZE SQ M / SQ FT 12385 FloorShell 0-47034-12385-5 1 20 rolls/pallet 0.97mx15.24m (38"x 50') 14.68 / 158 12380 FloorShell 0-47034-12380-0 1 16 rolls/pallet 0.97mx30.48m (38"x 100') 29.45 / 317 NOTE: Ask about our co-brand option; your logo custom printed on our construction board. FLOORSHELL® SEAM TAPE This 72mm tape covers FloorShell seams quickly and easily. Designed with kraft backing and contractor grade adhesive.
    [Show full text]
  • Principles Affecting Insulated Built-Up Roofs
    PRINCIPLES AFFECTING INSULATED BUILT-UP ROOFS \ C. E. LUND, M.S.(M.E.) PROFESSOR AND ASSISTANT DIRECTOR ENGINEERING EXPERIMENT STATION R. M. GRANUM, B.M.E. RESEARCH ASSOCIATE • BULLETIN NO. 34 UNIVERSITY OF MINNESOTA J. L. MORRILL, President INSTITUTE OF TECHNOLOGY A. F. SPILHAUS, Dean ENGINEERING EXPERIMENT STATION B. J. LAZAN, Director May 1952 ACKNOWLEDGMENT The authors gratefully acknowledge the cooperation of the Insulation Board Institute and the assistance of its Technical Committee in the planning, organization, and development of this research program. This committee includes D. B. Anderson, chairman (1951), B. F. Arendt, I. L. Birner, A. S. Bull, P. D. Close, J. H. Conover, R. E. Donnelly, 0. W. Frost, chairman (1946), D. L. Gleaves, A. E. Hughes, E. M. Jenkins, chairman (1947 and 1948), J. J. Perot, W. L. Scott, chairman (1949 and 1950), S. M. Van Kirk. technical secretary. We also wish to express our appreciation to Mr. Robert Paul, research fellow, for assfsting in the execution of the details of the program and publication of this bulletin. 1.490255 --------------------------------------------------------------------------------------- Table of Contents PAGE I INTRODUCTION .... 1 Roof Functions 1 Causes of Failure ............. 1 II VARIABLES AFFECTING RoOF CONSTRUCTION ....................... 4 Weather . .................................. 5 Workmanship 5 Materials .............................................. 6 III TYPES OF RooF FAILUREs ..... 6 Mechanical Failures 7 Construction Failures 7 Roof Blisters .... 7 Weather Blisters ......................... 8 Structural Blisters ...... 8 IV AIR, MOISTURE AND HEAT 11 Air and Moisture ....... 12 Moisture Capacity of Air .... 12 Pressures Exerted by Air and Moisture ... 13 Solar Heat . ....................................................................... .................... 16 V MOISTURE MIGRATION WITHIN ROOF STRUCTURES 17 Roof Surface Condensation 17 Structural Condensation ....... 19 High Inside Relative Humidity ..
    [Show full text]
  • IFB 16-056 2017 Roofing Projects
    Kansas City Kansas School District Project Manual IFB 16-056 2017 Roofing Projects December 2016 USD #500 2010 North 59th Street Kansas City, Kansas 66114 ADDENDUM No. 1 Kansas City Kansas Public Schools (USD #500) IFB 16-056 – 2017 Summer Roofing Projects December 19, 2016 You are instructed to read and note the following described changes, corrections, clarifications, omissions, deletions, additions, approvals and statements pertinent to the Construction Documents. Addendum No. 1 is a part of the Contract Bid and Construction Documents and shall govern in the performance of the Work. I. General Information A. School Fall classes start on August 14, 2017. Any roofing work not completed at this time shall only be completed during non-school hours. 1. Non-school hours: Evenings after 4:00 P.M. or weekends. B. All roofing work shall be 100% completed no later than September 3, 2016. C. All sheet metal work shall be 100% completed no later than September 15, 2016. D. Any roofing or sheet metal work not 100% complete by the above dates shall be accessed an $800 per day late fee for every day after these completion dates. E. Submit the attached Revise Bid Form with the following changes: 1. Several Attachment A forms have been adjusted per contractor request. 2. Base Bid #4 shall include Roofs 2, 2A, 14A, 14B, 15A, 26, and 27A. 3. Alternate Bid #1 shall include Roofs 14, 14C, 14D, 14E, and 27B. F. All materials listed on Attachment A forms shall ship prior to May 31, 2017 to protect against price increase on June 1, 2017.
    [Show full text]
  • Installation Instructions for All Hawa Bamboo & Wood Flooring Products
    HAWA Bamboo & Wood Products Corp. INSTALLATION INSTRUCTIONS FOR ALL HAWA BAMBOO & WOOD FLOORING PRODUCTS Before beginning the installation of Please read and review the entire any hardwood flooring product, the installer must determine that the control Installation Instruction Guide before of environment at the job site is operational before, during and after the proceeding with the actual installation installation and the type of the sub-floor involved is acceptable, according to industry standards, ensuring that it OWNER / INSTALLER RESPONSIBILITY Hardwood flooring is a beautiful and unique meets or exceeds all requirements which product of nature, which is characterized by distinctive variations in grain and color. These are stipulated in the HAWA Flooring natural variations in color and grain are not flaws, but are a part of the natural beauty and Installation Instruction Guide which uniqueness of hardwood flooring (these inherent variations should be expected and serve to follows. enhance the natural beauty and enduring charm.) HAWA floors are manufactured in accordance with accepted industry standards, which permit a defect tolerance not to exceed 5%. The defects may be of a manufacturing or natural type. (Remember: No two hardwood floors are alike.) The installer assumes all responsibility for final inspection to ensure the quality of the flooring. This inspection of all flooring should be done before installation. Carefully examine the flooring for color, finish, moisture content and quality before installing it. Use reasonable selectivity and cull out or cut off pieces with glaring defects. If material is not acceptable, DO NOT INSTALL and contact your HAWA flooring dealer/distributor immediately. INSTALLATION CONSTITUTES ACCEPTANCE.
    [Show full text]
  • GF-2019-R-0030 Design Build Services to Replace Gymnasium
    GF-20 I 9-R-0030 I. Solicitation No 2. Type 3. DIlIt' PO!!" UNIVERSITY.g~ Issued DISTRICT OF GF-20 19-R-0030 [ I 5""lo:d Bid COLUMBIA [ X] SI.."3Ic.."lI Proposal 317119 10(61 1851 4. Contract Number 5. Rcquisltlon/Purclulsc Request No. 6. Open Market with sct aside for SSE ROO l3129 [X 1 subcontracting (sec St.-clion M.l.6 [ ] SBE Set· Aside (Sec 8 .2 & 51.."(: . M) Mandatory 25% CBE subcontracting wilh Section M.2 5 and M. I 6 7. Inucd By: 8. Address Offer To: Uni"'c~ilY of the District of Columbia Mary Ann Harris, ChicfConlmcting Officer Office ofStrntcgic Sourcing and Procurement c'o James Jenkins, ScniorConlmct Specialist 4200 Connt..'C licut Avenue NW Bldg. 39 Suile 200C Umversity of the District of Columbia Washington, OC 20008 Office of Scmtcgic Sourcing and Procun:mcnt 4200 Conm."Clicul Avenue NW Bldg. 39 Suite 200C Washini!,lon. DC 20008 9. FOR A.Name B Telephone C. E-Mail Address INFORMATION CONTACT Jium ..'S Jenkins 202-274-5624 iam c.... .k nkinsta udc.(.-du IMPORTANT - The "Orreror" Section of this rorlll musl he rolllPlcced h,· lhe Orrcror SOLICIT A TION NOTE: In scaled bid solicitations "offer" and Offeror" mean "bid" and bidder" 10. St.-akd offers in "original plus 6 copies to perronn thc work R..-quired shall he r(.'CeiH-d :lot the place spl'Cific.>d in item 8, or hand carried to the bid counter locall..'tI at i1ddrcss shown in itt:m 8 not k'Ss than 2:0Q p...:..m.
    [Show full text]