Hanshaw Middle School Science Lab Modernization 1725 Las Vegas Street, Modesto, Ca 95358
Total Page:16
File Type:pdf, Size:1020Kb
Modesto City Schools 426 Locust Street, Modesto, CA 95351 - 2631 HANSHAW MIDDLE SCHOOL SCIENCE LAB MODERNIZATION 1725 LAS VEGAS STREET, MODESTO, CA 95358 DSA Application No. – 02-118933 CONTRACT DOCUMENTS, CONDITIONS & TECHNICAL SPECIFICATIONS DERIVI CASTELLANOS ARCHITECTS 3031 W. MARCH LANE, SUITE 334, STOCKTON, CA 95219 (209) 462.2873 NOT FOR CONSTRUCTION Technical Specifications for: HANSHAW MIDDLE SCHOOL SCIENCE LAB MODERNIZATION 1725 LAS VEGAS STREET, MODESTO, CA Prepared for: Modesto City Schools 426 Locust Street, Modesto, CA 95351 - 2631 Prepared by: Derivi Castellanos Architects 3031 W. March Lane, Suite 334, Stockton, CA 95219 Contact: Deborah A, Stevens , Architect (209) 372-5041 [email protected] DSA Appl. No. – 02-118933 DCA Job No. 20.025 March , 2021 HANSHAW MIDDLE SCHOOL DCA No. 20.025 SCIENCE LAB MODERNIZATION March, 2021 P R O J E C T D I R E C TOR Y: OWNER MODESTO CITY SCHOOLS ATTN: ROGER ORTH 1300 WOODLAND AVE MODESTO, CA 95351-1132 209. 574 - 1618 [email protected] ARCHITECT DERIVI CASTELLANOS ARCHITECTS ATTN: DEBORAH A. STEVENS 3031 W. MARCH LANE, SUITE 334 STOCKTON, CALIFORNIA 95219 209.462 - 2873 [email protected] STRUCTURAL DONALD C. URFER & ASSOC., INC. CONSULTANT ATTN: SCOTT HAGGBLADE 2715 PORTER STREET SOQUEL, CA 95073 831. 476.3681 [email protected] PLUMBING, LP CONSULTING ENGINEERS MECHANICAL ATTN: SEAN POURVAKIL ENGINEER. 1209 PLEASANT GROVE BLVD. ROSEVILLE, CA 95678 916 .851-3500 [email protected] ELECTRICAL LP CONSULTING ENGINEERS ENGINEER ATTN: ALEX SAEV 1209 PLEASANT GROVE BLVD. ROSEVILLE, CA 95678 916 .851-3500 [email protected] End – Project Directory PROJECT DIRECTORY 00 01 11-1 HANSHAW MIDDLE SCHOOL SCIENCE LAB MODERNIZATION ARCHITECT : STRUCTURAL ENGINEER Derivi Castellanos Architects Donald C. Urfer & Assoc. Inc. MECHANICAL ENGINEER : ELECTRICAL ENGINEER LP Consulting Engineers LP Consulting Engineers _________________________________ ____________________________________ IDENTIFICATION STAMP DIVISION OF STATE ARCHITECT OFFICE OF REGULATION SERVICES Appl. No. 02 –118933 AC_____________ FLS_____________SS_____________ DATE:__________________________ HANSHAW MIDDLE SCHOOL DCA No. 20.025 SCIENCE LAB MODERNIZATION March, 2021 T A B L E O F C O N T E N T S Coversheet Inside Cover Approval and Signatures Table of Contents DIVISION 00 – GENERAL CONDITIONS NOT IN THIS DOCUMENT DIVISION 1 – GENERAL REQUIREMENTS NOT IN THIS DOCUMENT TECHNICAL SPECIFICATIONS DIVISION 2 – SITE CONSTRUCTION Section 02 41 19 – Selective Demolition DIVISION 3 - CONCRETE Section 03 30 00 – Cast-In-Place Concrete Section 03 35 43 – Polished Concrete Finishing DIVISION 4 – MASONRY – Not Used DIVISION 5 – METAL – See Project Drawings DIVISION 6 – WOOD AND PLASTIC: Section 06 10 00 – Rough Carpentry Section 06 16 00 – Sheathing Section 06 18 00 – Glued Laminated Construction Section 06 41 16 – Architectural Woodwork DIVISION 7 – THERMAL & MOISTURE CONTROL: Section 07 21 00- Insulation Section 07 41 13 – Metal Roofing Section 07 60 00 – Flashing & Sheet Metal Section 07 92 00 – Joint Sealers DIVISION 8 – DOORS AND WINDOWS: Section 08 11 10 - Metal Doors and Frames Section 08 31 13 – Access Doors Section 08 71 00 - Door Hardware Section 08 80 00 - Glazing DIVISION 9 – FINISHES Section 09 24 00 – Cement Plastering Section 09 29 00 – Gypsum Board Section 09 51 00 – Acoustical Ceiling Section 09 65 13 – Resilient, Base & Accessories Section 09 72 00 – Presentation Dry-Erase Wall Covering Section 09 72 16 – Vinyl Tackboard Panels Section 09 91 13 – Exterior Painting – see Project Drawings Section 09 91 23 – Interior Painting MODESTO CITY SCHOOLS TABLE OF CONTENTS 00 01 10-1 HANSHAW MIDDLE SCHOOL DCA No. 20.025 SCIENCE LAB MODERNIZATION March, 2021 DIVISION 10 – SPECIALTIES Section 10 11 00 – Visual Display Units Section 10 14 00 – Signage & Graphics Section 10 21 13 – Toilet Compartments & Urinal Screens Section 10 28 00 – Toilet Accessories Section 10 44 13 – Fire Extinguishers DIVISION 11 Not Used DIVISION 12 – FURNISHINGS Section 12 36 00 – Laboratory Countertops/Cabinets - pending DIVISION 21 – FIRE SUPPRESSION Section 21 05 00 – Common Work Results for Fire Suppression Section 21 05 23 – General-Duty Valves for Water Based Fire Suppression Piping Section 21 05 53 – Identification for Fire Suppression Piping and Equipment Section 21 13 00 – Fire Suppression Sprinkler System DIVISIONS 22 – Plumbing: Section 22 05 10 – Plumbing – General Provisions Section 22 05 16 – Expansion Fittings and Loops for Plumbing Piping Section 22 05 23 – General Duty Valves for Plumbing Piping Section 22 05 29 – Hangers and Supports for Plumbing Piping and Equipment Section 22 05 53 – Identification for Plumbing Piping And Equipment Section 22 07 19 – Plumbing Piping Insulation Section 22 10 05 – Plumbing Piping Section 22 10 06 – Plumbing Piping Specialties Section 22 30 00 – Plumbing Equipment Section 22 40 00 – Plumbing Fixtures DIVISIONS 23 – HEATING, VENTILATING & AIR-CONDITIONING: Section 23 05 10 – Mechanical General Provisions Section 23 05 29 – Hangers & Supports for HVAC Piping & Equipment Section 23 05 53 – Identification for HVAC Piping & Equipment Section 23 05 93 – Testing, Adjusting and Balancing for HVAC Section 23 07 13 – Duct Insulation Section 23 23 00 – Refrigerant Piping Section 23 31 00 – HVAC Ducts and Casings Section 23 33 00 – Air Duct Accessories Section 23 34 23 – HVAC Power Ventilators Section 23 37 00 – Air Outlets & Inlets Section 23 74 13 – Packaged, Outdoor, Central-Station Air Handling Units Section 23 81 26.13 – Small Capacity Split System Air Conditioners DIVISION 26 – ELECTRICAL: Section 26 01 10 – General Requirements, Electrical Section 26 02 10 – Electrical Demolition, General Requirements Section 26 05 19 – Low Voltage Electrical Power Conductors and Cables [600 V and Less] Section 26 05 26 – Grounding and Bonding for Electrical System Section 26 05 34 - Raceways Section 26 05 37 – Boxes Section 26 05 53 – Identification for Electrical System Section 26 09 23 – Lighting Control Devices Section 26 27 17 – Equipment Wiring MODESTO CITY SCHOOLS TABLE OF CONTENTS 00 01 10-2 HANSHAW MIDDLE SCHOOL DCA No. 20.025 SCIENCE LAB MODERNIZATION March, 2021 Section 26 27 26 – Wiring Devices Section 26 28 13 – Fuses Section 26 28 16 – Disconnects Section 26 51 00 – Interior Lighting DIVISION 28 – ELECTRONIC SAFETY AND SECURITY 28 31 20 – Fire Alarm System DIVISION 31 - EARTHWORK - Not Used – DIVISION 32 - EXTERIOR IMPROVEMENTS – Section 32 13 13 – Concrete Paving Section 32 31 20 – Decorative Metal Fencing – see Project Drawings DIVISION 33 - UTILITIES See Fire Sprinkler drawings End Table of Contents MODESTO CITY SCHOOLS TABLE OF CONTENTS 00 01 10-3 HANSHAW MIDDLE SCHOOL DCA No. 20.025 SCIENCE LAB MODERNIZATION March, 2021 Section 02 41 19 SELECTIVE DEMOLITION PART 1 -GENERAL 1.01 WORK INCLUDED A. Remove materials, systems, components, fixtures and equipment as designated and as required for modernization of Buildings A and B to provide for science lecture and lab rooms and science classrooms, as indicated on the project Demolition Plans B. Coordinate selective demolition with plumbing, mechanical and electrical work; cap and identify active utilities where not otherwise identified under Division 26 work. C. NOTE: No hazardous materials removal/abatement is included in the scope of contractor’s work. A copy of the recent HazMat Report is available at the facility’s Admin office. D. Contractor shall recycle demolished materials rather than landfill materials wherever possible. A.02 RELATED WORK A. Coordinate Selective Demolition with::construction waste management program. 1.03 SUBMITTALS A. Demolition procedures and operational sequence for review and acceptance by Owner/Architect. B. Reports: Submit typewritten reports of surveys conducted with the Owner before and after performance of demolition operations. C. Salvageable Items: Submit typewritten list of items to be salvaged, for Owner's approval. 1.04 QUALITY ASSURANCE A. Standards: Perform demolition in conformance with ANSI A10.6 and NFPA 241. B. Demolition Firm Qualifications: An experienced firm that has specialized in demolition work similar in material and extent to that indicated for this Project. C. Regulatory Requirements: Comply with governing EPA notification regulations before beginning selective demolition. Comply with hauling and disposal regulations of authorities having jurisdiction. D. Pre-demolition Conference: Conduct conference at Project site. 1.05 EXISTING CONDITIONS A. Site Surveys: 1. Following performance of demolition, inspect and report defects and structural weaknesses of construction and improvements partially demolished, cut, and removed; of construction and improvements remaining; and of adjacent construction and improvements. B. Protection: Protect the structural integrity of existing construction and improvements to remain. 1.06 PROTECTION A. Do not interfere with use of adjacent building spaces; maintain free and safe passage to and from. 1. Cover and protect existing materials when demolition work is performed in areas where existing materials have not been removed. B. Cease operation and notify Architect immediately if safety of structure appears to be endangered; take precautions to properly support structure. 1. Do not resume operation until safety is restored. 1.07 EXISTING SERVICES A. Disconnect or remove utility services as required for completion of Project; disconnect, MODESTO CITY SCHOOLS SELECTIVE DEMOLITION 02 41 00-1 HANSHAW MIDDLE SCHOOL DCA No. 20.025 SCIENCE LAB MODERNIZATION March, 2021 stub