Installation Instructions for Catalog Series 5530M and 5530MHV Adaptatone® Millennium Signal Electrical Specifications
Total Page:16
File Type:pdf, Size:1020Kb
Installation Instructions for Catalog Series 5530M and 5530MHV Adaptatone® Millennium Signal Electrical Specifications Dimensions Input Board Main Power 5530M 5530MHV Catalog Current (A) A 8 7/8" 11 1/2" Number Voltage Current Voltage Standby Tone On (225 mm) (292 mm) Standard Volume B 8 1/4" 9 3/4" (210 mm) (248 mm) 5530M-24AQ 24V DC 6 mA 24V DC 0.10 0.74 C 13" 14 1/4" 24V AC 50/60 Hz 0.10 1.3 (330 mm) (362 mm) 5530M-24N5 24V DC 6 mA 120V AC 50/60 Hz 0.10 0.36 6igure 1. Dimensions 5530M-120N5 120V 13 mA 120V AC 50/60 Hz 0.10 0.38 50/60 Hz Description and Operation 5530M-24Y6 24V DC 6 mA 125V DC* 0.10 0.21 250V DC* 0.02 0.10 Edwards Adaptatone is a heavy-duty, tone-selectable, stand 120V AC 50/60 Hz 0.10 0.32 alone, indoor/outdoor audible signaling device intended 240V AC 50/60 Hz 0.10 0.20 for industrial applications where high audible output and 5530M-120Y6 120V 13 mA 125V DC* 0.10 0.20 microcomputer reliability are required. Catalog Numbers 50/60 Hz 250V DC* 0.02 0.10 ending with suffixes -24AQ or -24Y6 are CE Marked and 120V AC 50/60 Hz 0.10 0.31 TÜV-RHEINLAND Certified for compliance to the European 240V AC 50/60 Hz 0.10 0.20 Union's Electromagnetic Compatibility (Industrial) and Low High Volume Voltage Safety Directives (see Declaration of Conformity, available upon request). Additionally, the Adaptatone Mil- 5530MHV-24AQ 24V DC 6 mA 24V DC 0.10 1.5 lennium series are UL and cUL Listed as Audible Signal 24V AC 50/60 Hz 0.10 2.3 Appliances for use in the following hazardous locations. 5530MHV-24Y6 24V DC 6 mA 125V DC* 0.10 0.39 250V DC* 0.02 0.19 Catalog Hazardous Temp. 120V AC 50/60 Hz 0.10 0.56 Number Locations Code 240V AC 50/60 Hz 0.10 0.34 5530M-24AQ Class I, Div. 2, Groups A, B, C, D T4 (135C) 5530MHV-120Y6 120V 13 mA 125V DC* 0.10 0.40 5530M-24N5 Class II, Div. 2, Groups 6, G T5 (100C) 50/60 Hz 250V DC* 0.02 0.20 5530M-24Y6 Class III, Div. 1 and 2 120V AC 50/60 Hz 0.10 0.62 5530M-120N5* 240V AC 50/60 Hz 0.10 0.37 5530M-120Y6* *CE mark and TÜV-Rheinland Certifications do not apply to 125V DC or 250V DC. 5530MHV-24AQ 5530MHV-24Y6 5530MHV-120Y6* Installation *Catalog Numbers ending in -120Y6 or -120N5 are NOT cUL Listed. The Adaptatone may be mounted to any flat surface or The Adaptatone operates from local power and sounds a may be used as a freestanding unit mounted to a rigid high decibel signal determined by the setting of minia- pipe. The Adaptatone must be installed in accordance ture programming switches inside the unit. The with the latest edition of the National Electrical Code or Adaptatone may be programmed for any of the 27 tones other regulations applicable to the country and locality listed in 6igure 16. of installation and by a trained and qualified electrician. Speaker direction and the output level are easily adjust- 6or catalog numbers ending in "AQ", 24V AC power must able. be transformer isolated from mains or line power. Mechanical Specifications CAUTION During installation, care must be taken so that components Weight ................................................... 9 Pounds (4.1 kg) on the printed circuit board are not damaged. Hazardous Locations, UL Standard UL1604 Ambient Temp. ................... +416 to +1046 (+5C to +40C) 1. Mount Adaptatone as shown in 6igure 2. Non-Hazardous Locations a. lat Surface Mounting. Secure unit to Variable Ambient Temp. ..... -406 to +1516 (-40C to +66C) mounting surface using the (4) mounting holes in the mounting plate on the rear of the box. Use Hazardous Locations and Variable Ambient Conditions apply only the #10 x 3" (76 mm) wood screws (furnished loose) where UL listings are accepted and do not apply to CE conformity or or other hardware (not supplied) suitable for the TÜV-Rheinland Certification. mounting surface. b. Rigid Pipe Mounting. Loosen the (4) cover screws from the signal box and lift off signal box cover. CHESHIRE, CT 203-699-3300 FAX 203-699-3365 (CUST. SERV.) 203-699-3078 (TECH SERV.) P/N 3100006 ISSUE 1 © 2001 Table 1. Programming Logic Controller (PLC) Compatibility: PLC output to meet following product input parameters. See 6igures 11 and 14. Operating voltage Max. off state Continuous on current Surge (inrush/duration) Cat. No. (Volts) leakage current (mA) (mA) (Amps/milliSeconds) 5530M-24AQ 24V DC only 2 740 8/4 5530M-24N5 120V 60 Hz 2 360 2.82/4 5530M-120N5 120V 60 Hz 5 380 2.82/4 5530MHV-24AQ 24V DC only 2 1500 8/4 Input Board Circuit 24V DC 2 6 -- Input Board Circuit 120V 60 Hz 5 13 -- NOTE: Cover screws are captive. Do not remove from d. Optional. Connect external 24V DC battery (not cover. supplied) in series with separate diode assembly part 2600010 (supplied) to TB1 terminals 3 and 4 Remove the center knockout in lower wall of box on the main board as shown in 6igures 3 and 4 and mount box to a 1/2" (12.7 mm) conduit pipe and marked on the diode assembly. using suitable connector. NOTE: Terminal Block TB1 can be unplugged from the 2. Install wires through a knockout hole in the bottom main board to complete wiring as shown in of the box from a raceway that is, with its connections $igure 3. to the 1/2" (12.7 mm) conduit knockout hole, approved for the same degree of protection and enclosure type 4. Refer to 6igures 15 and 16 and select desired tones. needed by the application. Use the provided plastic Set miniature programming switches on the input tie-wrap, on the barrier to the electronics, to separate board. incoming power leads from signal and tone initiating leads, per NEC (6igure 5). WARNINGS WARNING HIGH VOLTAGE is present when product is energized. High To prevent fire and shock, wire the Adaptatone only as volume may cause harm to personnel in close proximity. described in this installation instruction. 5. Adjust volume level, if desired, by turning 3. Wire as follows referring to 6igure 5. potentiometer located on the main board (6igure 11). a. Connect green and yellow-striped earth-ground WARNING wires to earth-ground. To ensure integrity of the Adaptatone assembly when b. Select the appropriate method for wiring to the adjusting the speaker direction, make sure threads in the input board from 6igures 6 - 11 for models with enclosure remain fully engaged and do not turn speaker 24V input board or 6igures 12 - 14 for models with more than 360 degrees from the original factory installed 120V input board. position. c. Connect incoming power to wire leads using a 6. To adjust speaker direction, loosen large star nut butt splice or other method listed, certified, or (6igure 2) and turn speaker to the approximate desired otherwise approved by local authorities. Leads position. Retighten nut and turn speaker slightly are both black for -AQ and -N5 models and are clockwise until locked into place. black and white for -Y6 models. WARNING To ensure integrity of the enclosure: Ensure the cover gasket, part number P-007549-0069, is adhered into groove at cover perimeter before replacing the signal box cover. Speaker Ensure that the (4) collar gaskets, part number P-041930- 0362, are in place on each cover screw before securing the signal box cover. Large star nut to When securing cover, start screws by hand, making sure adjust speaker direction they are threaded into tapped holes in housing bosses Signal Box before securing with a screwdriver. Torque signal box cover (4) Cover screws to a minimum of 20 in-lbs. This ensures the screws required tight fit. (4) Collar gaskets (4) #10 x 3" (76 mm) Raceway and connections 7. Tightly secure the signal box cover using (4) retained screws or other hardware (not supplied) to cover screws. suitable for the mounting surface 1/2" (12.7 mm) knockout 6igure 2. Adaptatone Mounting 8. Torque signal box cover screws to a minimum of 20 in-lbs. P/N 3100006 ISSUE 1 Page 2 9. Verify operability. Maintenance and Test CAUTION Ensure that power is disconnected before cleaning inside of unit. Examine the unit semi-annually for accumulation of dirt. Clean if necessary. The Adaptatone should be tested annually or as required by the authority having jurisdiction to ensure continuous service. 2 4 1 Terminal Block 3 TB-1 Main Board 6igure 3. Terminal Block TB1 2 (-) (-) 4 24 1 Wiring is factory installed to internal To optional 24V DC power supply Battery Backup 3 13 See 6igure 3 for terminal block location on the main board (+) (+) Diode Assembly 2600010 6igure 4. Wiring to Terminal Block TB1 Input Circuit Power and Signal/Tone initiating leads to be earth-ground connected to Input Board leads Plastic tie-wrap (provided)-- use to separate power leads from signal and tone initiating leads 6igure 5. Wiring the Adaptatone Page 3 P/N 3100006 ISSUE 1 IN4 N +VS GND IN4 N +VS GND (5V DC to 24V DC +/- 1%) K1 INPUT FROM CUSTOMER CIRCUIT RELAY 6igure 6. Wiring to 24V Input Board with an 6igure 7. Wiring a Dry Relay Contact to 24V Input Open Collector Transistor Board, Method 1 (Refer to Applications Engineering for compatibility with earlier versions of Adaptatone) IN4 N +VS GND IN4 N +VS GND K1 RELAY 6igure 8.