Alcatel-Lucent 7705 SERVICE AGGREGATION ROUTER OS | RELEASE 7.0.R4 OAM and DIAGNOSTICS GUIDE

Total Page:16

File Type:pdf, Size:1020Kb

Alcatel-Lucent 7705 SERVICE AGGREGATION ROUTER OS | RELEASE 7.0.R4 OAM and DIAGNOSTICS GUIDE OAM AND DIAGNOSTICS GUIDE Alcatel-Lucent 7705 SERVICE AGGREGATION ROUTER OS | RELEASE 7.0.R4 OAM AND DIAGNOSTICS GUIDE Alcatel-Lucent – Proprietary & Confidential Contains proprietary/trade secret information which is the property of Alcatel-Lucent. Not to be made available to, or copied or used by anyone who is not an employee of Alcatel-Lucent except when there is a valid non- disclosure agreement in place which covers such information and contains appropriate non-disclosure and limited use obligations. Copyright © 2015 Alcatel-Lucent. All rights reserved. All specifications, procedures, and information in this document are subject to change and revision at any time without notice. The information contained herein is believed to be accurate as of the date of publication. Alcatel- Lucent provides no warranty, express or implied, regarding its contents. Users are fully responsible for application or use of the documentation. Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners. Copyright 2015 Alcatel-Lucent. All rights reserved. Disclaimers Alcatel-Lucent products are intended for commercial uses. Without the appropriate network design engineering, they must not be sold, licensed or otherwise distributed for use in any hazardous environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation or communication systems, air traffic control, direct life-support machines, or weapons systems, in which the failure of products could lead directly to death, personal injury, or severe physical or environmental damage. The customer hereby agrees that the use, sale, license or other distribution of the products for any such application without the prior written consent of Alcatel-Lucent, shall be at the customer's sole risk. The customer hereby agrees to defend and hold Alcatel-Lucent harmless from any claims for loss, cost, damage, expense or liability that may arise out of or in connection with the use, sale, license or other distribution of the products in such applications. This document may contain information regarding the use and installation of non-Alcatel-Lucent products. Please note that this information is provided as a courtesy to assist you. While Alcatel-Lucent tries to ensure that this information accurately reflects information provided by the supplier, please refer to the materials provided with any non-Alcatel-Lucent product and contact the supplier for confirmation. Alcatel-Lucent assumes no responsibility or liability for incorrect or incomplete information provided about non-Alcatel-Lucent products. However, this does not constitute a representation or warranty. The warranties provided for Alcatel-Lucent products, if any, are set forth in contractual documentation entered into by Alcatel-Lucent and its customers. This document was originally written in English. If there is any conflict or inconsistency between the English version and any other version of a document, the English version shall prevail. Table of Contents Preface................................................................................................................................................... 11 About This Guide................................................................................................................................................11 Audience .......................................................................................................................................................12 List of Technical Publications ........................................................................................................................12 Technical Support .........................................................................................................................................13 Getting Started...................................................................................................................................... 15 In This Chapter ...................................................................................................................................................15 Alcatel-Lucent 7705 SAR OAM Configuration Process......................................................................................15 OAM and SAA ....................................................................................................................................... 17 In This Chapter ...................................................................................................................................................17 OAM Overview ...................................................................................................................................................18 ICMP and ICMPv6 Diagnostics .....................................................................................................................19 Ping ..........................................................................................................................................................19 Traceroute................................................................................................................................................19 Two-Way Active Measurement Protocol ......................................................................................................19 7705 SAR Support for TWAMP Server ....................................................................................................21 Two-Way Active Measurement Protocol Light (TWAMP Light)................................................................24 LSP Diagnostics ............................................................................................................................................26 LSP Ping ..................................................................................................................................................27 LSP Traceroute ........................................................................................................................................27 LSP Ping and LSP Traceroute for BGP Route Tunnels...........................................................................27 Downstream Detailed Mapping (DDMAP) TLV ........................................................................................29 SDP Diagnostics ...........................................................................................................................................35 SDP Ping..................................................................................................................................................35 SDP MTU Path Discovery........................................................................................................................36 Service Diagnostics.......................................................................................................................................36 Service Ping .............................................................................................................................................37 VLL Diagnostics ............................................................................................................................................37 VCCV Ping ...............................................................................................................................................37 VCCV Trace .............................................................................................................................................44 ITU-T Y.1564 Diagnostics .............................................................................................................................45 ITU-T Y.1564 Functionality ......................................................................................................................47 ITU-T Y.1564 Protocol Interaction............................................................................................................48 VPLS MAC Diagnostics.................................................................................................................................49 MAC Ping .................................................................................................................................................49 MAC Trace ...............................................................................................................................................50 CPE Ping..................................................................................................................................................51 MAC Populate ..........................................................................................................................................51 MAC Purge...............................................................................................................................................52 Ethernet OAM Capabilities ............................................................................................................................53 Ethernet OAM Overview ..........................................................................................................................53 802.1ag and Y.1731 Functional Comparison...........................................................................................56 ETH-CFM Ethernet OAM Tests (802.1ag and Y.1731)............................................................................57
Recommended publications
  • 599.061801Er – Movable Bridge Control System
    ITEM 599.061801ER – MOVABLE BRIDGE CONTROL SYSTEM DESCRIPTION 1.01 GENERAL REQUIREMENT A. This section includes general requirements for supply, delivery, storage, installation, testing and commissioning of the Control System required under the scope of the contract. B. Provide supervision, labor, and assistance to manufacturer’s field representative and/or technical directors for equipment to be installed as a part of this Contract. C. The Contractor shall provide service of qualified system integration company to develop and produce substantially completed electrical installation shop drawings as integrated system for Engineer’s review and approval. The substantially completed installation shop drawings shall be developed based on the final shop drawings of the actual equipment procured. The substantially completed installation shop drawings shall include layout/assembly/installation drawings of equipment, components terminal boxes and terminations drawings, schematic diagrams, point-to-point interconnection wirings with cable tags and termination identification for field installation. The Contractor shall coordinate all activities required to produce the substantially completed installation shop drawings. D. The design drawings of the control system are intended to convey functional and performance requirements of the movable bridge control system. The design drawings of the control system does not show all of the required components and circuit wiring interconnections required to provide a complete and fully function bridge control system. The contractor shall provide a fully integrated, complete automation control system, fully programmed (in terms of automation, control logic, operator interface, alarm and events logging) and ready for proper operation of the movable bridge. The supply shall be complete and shall include all equipment and components, system interconnections, configuration and software programming necessary to guarantee the proper control of the movable bridge from operator control panel and/or HMI.
    [Show full text]
  • Application of Ethernet Networking Devices Used for Protection and Control Applications in Electric Power Substations
    Application of Ethernet Networking Devices Used for Protection and Control Applications in Electric Power Substations Report of Working Group P6 of the Power System Communications and Cybersecurity Committee of the Power and Energy Society of IEEE September 12, 2017 1 IEEE PES Power System Communications and Cybersecurity Committee (PSCCC) Working Group P6, Configuring Ethernet Communications Equipment for Substation Protection and Control Applications, has existed during the course of report development as Working Group H12 of the IEEE PES Power System Relaying Committee (PSRC). The WG designation changed as a result of a recent IEEE PES Technical Committee reorganization. The membership of H12 and P6 at time of approval voting is as follows: Eric A. Udren, Chair Benton Vandiver, Vice Chair Jay Anderson Galina Antonova Alex Apostolov Philip Beaumont Robert Beresh Christoph Brunner Fernando Calero Christopher Chelmecki Thomas Dahlin Bill Dickerson Michael Dood Herbert Falk Didier Giarratano Roman Graf Christopher Huntley Anthony Johnson Marc LaCroix Deepak Maragal Aaron Martin Roger E. Ray Veselin Skendzic Charles Sufana John T. Tengdin 2 IEEE PES PSCCC P6 Report, September 2017 Application of Ethernet Networking Devices Used for Protection and Control Applications in Electric Power Substations Table of Contents 1. Introduction ...................................................................................... 10 2. Ethernet for protection and control .................................................. 10 3. Overview of Ethernet message
    [Show full text]
  • PT-G7509 Series IEC 61850-3 9G-Port Layer 2 Full Gigabit Managed Rackmount Ethernet Switches
    Datasheet Industry-specific Ethernet Switches PT-G7509 Series IEC 61850-3 9G-port Layer 2 full Gigabit managed rackmount Ethernet switches › IEC 61850-3, IEEE 1613 (power substations) compliant › VLAN Unaware: Supports priority-tagged frames to be received by specific IEDs › Turbo Ring, Turbo Chain, RSTP/STP, and MSTP for network redundancy › Isolated redundant power supplies with universal 24 VDC, 48 VDC, or 110/220 VDC/VAC power supply range › -40 to 85°C operating temperature range Introduction The PowerTrans PT-G7509 is equipped with 9 combo Gigabit Ethernet performance and transfer large amounts of video, voice, and data across ports, making it ideal for upgrading an existing network to Gigabit speeds a network quickly. The redundant Ethernet Turbo Ring, Turbo Chain, and and building a new full Gigabit backbone. The PT-G7509 is designed to RSTP/STP/MSTP (IEEE 802.1w/D/s) functions increase system reliability meet the demands of power substation automation systems (IEC 61850-3, and the availability of your network backbone. The choice of either front or IEEE 1613). Gigabit transmission increases bandwidth to provide higher rear wiring makes the PT-G7509 suitable for different types of application. General Features and Benefits • Command line interface (CLI) for quickly configuring major • IGMP snooping and GMRP for filtering multicast traffic from managed functions industrial Ethernet protocols • IPv6 Ready logo awarded (IPv6 Logo Committee certified) • IEEE 802.3ad, LACP for optimum bandwidth utilization • Software-based IEEE 1588v2
    [Show full text]
  • TSL-1 Appendix B Non-Government
    U.S DEPARTMENT OF ENERGY TECHNICAL STANDARDS PROGRAM TSL-1 APPENDIX B: Non-Government Standards (NGS) Adopted by DOE 10 AMD 1 Standard for Portable Fire Extinguishers 2012 NESC Handbook National Electrical Safety Code(NESC) Handbook 310.2R-2013 International Concrete Repair Institute (ICRI) Selecting and Specifying Concrete Surface Preparation for Sealers, Coatings Polymer Overlays, and Concrete Repair A 112.18.1M Plumbing Fixture Fittings A 112.19.6 Hydraulic Requirements for Water Closets and Urinals AA SAA-46-516124 Anodized Architectural Aluminum AA Specifications for Aluminum Structures AA STFA-601711 The Surface Treatment and Finishing of Aluminum and Its Alloys AABC National Standard for Total System Balance Air Distribution-Hydronic Systems-Sound-Vibration- Field Surveys for Energy Audits AAHC Standards of the Accreditation Association for Ambulatory Health Care (AAAHC), Core and Adjunct Standards AAMA 1002.10 Aluminum Insulating Storm Products for Windows and Sliding Glass Doors AAMA 1002.9 Voluntary Specifications for Aluminum Combination Storm Windows for External Applications AAMA 101 Voluntary Specifications for Aluminum Prime Windows and Sliding Glass Doors AAMA 101/I.S.2 Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors AAMA 1102.7 Voluntary Specifications for Aluminum Storm Doors AAMA 611 Anodized Architectural Aluminum AAMA 800 Sealant Specifications for Use with Architectural Aluminum AASHTO AAB Above and Beyond – The Environmental and Social Contributions of America’s Highway Programs
    [Show full text]
  • Rlxe4ge24modms Hardened Layer 3 Managed 10 Gigabit Modular Ethernet Switch
    INSTALLATION AND OPERATION MANUAL RLXE4GE24MODMS HARDENED LAYER 3 MANAGED 10 GIGABIT MODULAR ETHERNET SWITCH The ComNet RLXE4GE24MODMS is a Layer-3 modular managed redundant ring configurable Ethernet switch. It has four slots that can accommodate individual modules that feature different combinations of SFP and electrical TX ports. One of the slots can accommodate a 10 gigabit module with either 2 or 4 10 Gbps or 1 Gbps SFP ports. The switch is designed for security, ITS, power substation and rolling stock applications, and is fully compliant with the requirement of IEC 61850-3 and IEEE 1613 as well as NEMA TS1/TS2. The RLXE4GE24MODMS switch supports multiple Ethernet Redundancy protocols, including C-Ring (recovery time < 30ms over 250 units of connection) and MSTP (RSTP/STP compatible). This switch can protect critical applications from network interruptions or temporary malfunctions with its fast recovery technology. This environmentally hardened switch is designed for direct deployment in difficult out-of-plant or roadside operating environments. INSTALLATION AND OPERATION MANUAL RLXE4GE24MODMS Contents About This Guide 6 Related Documentation 6 About ComNet 6 Website 6 Support 6 Safety 6 Overview 7 Introduction 7 Software Features 8 Hardware Features 9 Hardware Installation 10 Installing RJ-45 Module in RLXE4GE24MODMS 10 Installing SFP Module in RLXE4GE24MODMS 10 Installing 10 Gbps SFP+ Module in RLXE4GE24MODMS 11 Installing Power Module in RLXE4GE24MODMS 11 Hardware Overview 12 Front Panel 12 Power Panel 14 Rack mount kit assembly
    [Show full text]
  • Industrial Networking Solutions for Mission Critical Applications
    www.hirschmann.com GLOBAL LOCATIONS Industrial Networking Solutions for Mission Critical Applications For more information, please visit us at: www.belden.com/hirschmann Industrial Networking Solutions for Mission Critical Applications Critical Mission Industrial for Networking Solutions UNITED STATES CANADA LATIN AMERICA and the CARIBBEAN ISLANDS Division Headquarters Industrial Networking National Business Regional Office – Americas (Hirschmann/GarrettCom/ Center 6100 Hollywood Boulevard 2200 U.S. Highway 27 South Tofino Security) 2280 Alfred-Nobel Suite 110 Richmond, IN 47374 255 Fourier Ave. Suite 200 Hollywood, Florida 33024 Phone: 765-983-5200 Fremont, CA 94539, USA Saint-Laurent, QC Phone: 954-987-5044 Canada H4S 2A4 Inside Sales: 800-235-3361 Phone: 510-438-9071 Fax: 954-987-8022 Fax: 765-983-5294 Fax: 510-952-3456 Phone: 514-822-2345 [email protected] [email protected] www.belden.com Fax: 514-822-7979 www.belden.com [email protected] Belden 2200 U.S. Highway 27 South Richmond, IN 47374a Inside Sales: 1-800-BELDEN-1 (1-800-235-3361) Industry-specific solutions that can Phone: 765-983-5200 Fax: 765-983-5294 improve productivity and operational [email protected] efficiency today, while laying the foundations for tomorrow‘s IIoT opportunities. Belden, Belden Sending All The Right Signals, GarrettCom, Hirschmann, Lumberg Automation, Tofino Security, Tripwire and the Belden logo are trademarks or registered trademarks of Belden Inc. or its affiliated companies in the United States and other jurisdictions. Belden and other parties may also have trademark rights in other terms used herein. Edition 2017 ©Copyright 2017, Belden Inc. Edition 2017 Printed in Germany HIRSCHMANN-INDUSTRIAL-NETWORKING-SOLUTIONS_CA_INIT_HIR_0117_A_AG Prepare your infrastructure for the Industrial Internet of Things (IIoT) The IIoT is widely considered to be one of the primary trends affecting industrial businesses today and in the future.
    [Show full text]
  • The Design of an IEEE 1588 End-To-End Transparent Ethernet Switch
    The Design of an IEEE 1588 End-to-end Transparent Ethernet Switch by Caleb Gordon A thesis submitted to the Victoria University of Wellington in fulfilment of the requirements for the degree of Master of Science in Electronic and Computer Systems Engineering. Victoria University of Wellington 2008 Abstract In measurement and control systems there is often a need to synchronise distributed clocks. Traditionally, synchronisation has been achieved using a dedicated medium to convey time information, typically using the IRIG-B serial protocol. The precision time protocol (IEEE 1588) has been designed as an improvement to current methods of synchronisation within a dis- tributed network of devices. IEEE 1588 is a message based protocol that can be implemented across packet based networks including, but not lim- ited to, Ethernet. Standard Ethernet switches introduce a variable delay to packets that inhibits path delay measurements. Transparent switches have been introduced to measure and adjust for packet delay, thus removing the negative effects that these variations cause. This thesis describes the hardware and firmware design of an IEEE 1588 transparent end-to-end Ethernet switch for Tekron International Ltd based in Lower Hutt, New Zealand. This switch has the ability to monitor all Ethernet traffic, identify IEEE 1588 timing packets, measure the delay that these packets experience while passing through the switch, and account for this delay by adjusting a time-interval field of the packet as it is leaving the switch. This process takes place at the operational speed of the port, and without introducing significant delay. Time-interval measurements can be made using a high-precision timestamp unit with a resolution of 1 ns.
    [Show full text]
  • Standards Action Layout SAV3718.Fp5
    PUBLISHED WEEKLY BY THE AMERICAN NATIONAL STANDARDS INSTITUTE 25 West 43rd Street, NY, NY 10036 VOL. 37, #18 May 5, 2006 Contents American National Standards Call for Comment on Standards Proposals ................................................ 2 Call for Comment Contact Information ....................................................... 10 Final Actions.................................................................................................. 12 Project Initiation Notification System (PINS).............................................. 13 International Standards ISO Draft Standards ...................................................................................... 20 ISO and IEC Newly Published Standards.................................................... 21 Registration of Organization Names in the U.S............................................ 23 Proposed Foreign Government Regulations................................................ 23 Information Concerning ................................................................................. 24 American National Standards Call for comment on proposals listed This section solicits public comments on proposed draft new American National Standards, including the national adoption of Ordering Instructions for "Call-for-Comment" Listings ISO and IEC standards as American National Standards, and on 1. Order from the organization indicated for the specific proposals to revise, reaffirm or withdraw approval of existing proposal. American National Standards. A draft standard is listed
    [Show full text]
  • Electromagnetic Compatibility and Smart Grid Interoperability Issues
    SMART GRID INTEROPERABILITY PANEL Electromagnetic Compatibility and Smart Grid Interoperability Issues SGIP Electromagnetic Interoperability Issues Working Group SGIP Document Number: 2012-005 , Version 1.0 Document Source: December 5, 2012 Author/Editor: EMII WG/Galen Koepke (chair) Production Date: December 5, 2012 Electromagnetic Compatibility and Smart Grid Interoperability Issues THE SGIP The Smart Grid Interoperability Panel (SGIP) is a membership-based organization established by the National Institute of Standards and Technology (NIST) and administered by its members, as facilitated by a NIST contractor. It provides an open process for stakeholders to participate in providing input and cooperating with NIST in the ongoing coordination, acceleration and harmonization of standards development for the Smart Grid. The SGIP reviews use cases, identifies requirements and architectural reference models, coordinates and accelerates Smart Grid testing and certification, and proposes action plans for achieving these goals. The SGIP does not write standards, but serves as a forum to coordinate the development of standards and specifications by many Standards Setting Organizations (SSOs). RIGHT TO DISTRIBUTE AND CREDIT NOTICE This material was created by the Smart Grid Interoperability Panel (SGIP) and is available for public use and distribution. Please include credit in the following manner: Electromagnetic Compatibility and Smart Grid Interoperability Issues, 2012- 005, December 5, 2012. DISCLAIMER This document is a work product of the
    [Show full text]
  • EX70900 Series IEC 61850-3/IEEE 1613 Hardened Managed 8-Port Gigabit Ethernet Switch
    EX70900 Series IEC 61850-3/IEEE 1613 Hardened Managed 8-port Gigabit Ethernet Switch SFP Option Overview EtherWAN's EX70900 Series provides a Hardened Fully Managed 8-port switching platform combining high performance switching backbone with robust and secure management features required for mission critical and harsh environments where sustained connectivity is crucial. Mountable on a DIN-Rail, the EX70900 Series is a full Gigabit hardened managed switch, featured with 6 ports of 10/100/1000BASE- TX, in combination with up to two SFP port options. Users are able to access management features such as; port security, IGMP snooping, VLANs, GARP protocols, LACP to name a few, via web browser, Telnet, SNMP, RMON, TFTP, and RS-232 console interfaces. With its hardened-grade specifications and IEC 61850 certifications, the EX70900 Series is capable of operating under high EMI environments at the temperatures ranging from -40 to 75°C, making it an ideal choice for harsh applications. EtherWAN – "When Connectivity is Crucial." Spotlight • Full Gigabit Connectivity ◦ Managed Hardened 8-port Gigabit Ethernet switch with either copper, SC, ST or LC connectors available • Intelligent Data Management ◦ Optimize network performance with QoS, VLAN etc. • Compliance with IEC 61850-3/IEEE 1613 ◦ For installations with high EMS requirements • Energy Efficient Ethernet (EEE) ◦ Supports IEEE 802.3az standard EX70900 Series 1 www.EtherWAN.com rev. A6.3 Software Features Management • Interface ◦ CLI, Telnet and Web Browser ◦ SNMP v1/v2c/v3 • Firmware and configuration
    [Show full text]
  • POWER SYSTEM RELAYING COMMITTEE of the IEEE POWER and ENERGY SOCIETY MINUTES of the MEETING January 9-12, 2012 Garden Grove, CA Final I
    POWER SYSTEM RELAYING COMMITTEE OF THE IEEE POWER and ENERGY SOCIETY MINUTES OF THE MEETING January 9-12, 2012 Garden Grove, CA Final I. Call to order / Introductions Bob Pettigrew Chairman Bob Pettigrew called the meeting to order at 8:00 am After introductions, a quorum was verified (88 members – 148 total present) and Main Committee Attendance sheet was routed. II. Approval of Minutes & Financial Report Mike McDonald The minutes of the Minneapolis September 2011 meeting were approved as posted. The PSRC had no financial responsibility for this meeting. Chairman’s Report Bob Pettigrew None III. Reports of Interest A. Technical Paper Coordinator’s Report – Roger Hedding 2012 T&D Conference, May 7 – 10, 2012 Orlando The theme is “Making Innovation work for Tomorrow”. 14 papers were submitted for the conference. 13 were accepted, 1 was rejected. All the papers will be at the poster session Wednesday evening. Thanks to all the reviewers who helped review these papers. 2012 General Meeting, July 22- 27, 2012 San Diego 49 papers were submitted for review to the PSRC for the 2012 general meeting. Reviews are to be completed by January 23 rd . To date 3 papers have been accepted, and 3 rejected. We will sponsor 4 -5 paper sessions for this meeting. I’ll need Session chairs. So if you are interested, let me know. Paper Approval Criteria More information on this as task force results are presented. Nothing to report as of this date. Future Meetings May 13-17, 2012 Astor Crowne Plaza Hotel, New Orleans Sept. 10-13, 2012 Hilton Portland; Portland, OR Jan 2013 JTCM (TBD) May 12-16, 2013 Tremont Plaza Hotel, Baltimore, MD Sept.
    [Show full text]
  • Industrial Management Ethernet Switch
    iRBX6GF User’s Manual Intelligent 6 Port HSR/PRP Ethernet Switch IEC 61850 and IEEE 1613 Compliant Version 1.3 March 2015 iRBX6GF User’s Manual COPYRIGHT NOTICE Copyright © 2013 iS5 Communications Inc. All rights reserved. No part of this publication may be reproduced in any form without the prior written consent of iS5 Communications Inc. (iS5). TRADEMARKS iS5Com is a registered trademark of iS5. All other trademarks belong to their respective owners. REGULATORY COMPLIANCE STATEMENT Product(s) associated with this publication complies/comply with all applicable regulations. Please refer to the Technical Specifications section for more details. WARRANTY iS5 warrants that all products are free from defects in material and workmanship for a specified warranty period from the invoice date (5 years for most products). iS5 will repair or replace products found to be defective within this warranty period including shipping costs. This warranty does not cover product modifications or repairs done by persons other than iS5-approved personnel, and this warranty does not apply to products that are misused, abused, improperly installed, or damaged by accident. Please refer to the Technical Specifications section for the actual warranty period(s) of the product(s) associated with this publication. DISCLAIMER Information in this publication is intended to be accurate. iS5 shall not be responsible for its use or infringements on third-parties as a result of its use. There may occasionally be unintentional errors on this publication. iS5 reserves the right to revise the contents of this publication without notice. CONTACT INFORMATION iS5 Communications Inc. #3-7490 Pacific Circle, Mississauga, Ontario, L5T 2A3 Tel: + 905-670-0004 // Fax: + 289-401-5206 Website: www.iS5Com.com Technical Support E-mail: [email protected] Sales Contact E-mail: [email protected] iS5 Communications Inc.
    [Show full text]