What's on Tap? -- Philadelphia

Total Page:16

File Type:pdf, Size:1020Kb

What's on Tap? -- Philadelphia WHAT’S ON TAP? Grading Drinking Water in U.S. Cities June 2003 Medical journal studies have reported illnesses in PHILADELPHIA, PA children and the elderly associated with Philadelphia Philadelphia Earned a Water Quality and Compliance tap water, which may be the result of Cryptosporidium Grade of Fair in Both 2000 and 2001 (Crypto), which has been found in the city’s source Philadelphia had no reported violations but had levels waters. Crypto is a waterborne microbial disease- of chlorination by-products that averaged near the new carrying pathogen that presents health concerns, EPA standard and occasionally spiked above it. In especially to individuals with weakened immune addition, the city had significant lead levels, possible systems. The city has improved its treatment somewhat medical evidence of waterborne disease, and occasional to try to address these problems. contamination with pesticides and industrial chemicals. Chemical spills, runoff, discharges of cancer-causing and other toxic pollutants, and microbial contaminants The Philadelphia Water Department had no recent reported violations of current, pending, or proposed periodically contaminate the Schuylkill and Delaware national standards in 1999–2001.1 Rivers and sometimes city tap water. Occasionally pol- lutant levels exceed national health goals but are found Levels of chlorination by-products, specifically total trihalomethanes (TTHMs) and haloacetic acids (HAAs), at levels below national standards. An effort to inven- averaged as high as 80 percent of the new national tory and address these pollution problems has begun. standards and occasionally spiked above those Philadelphia’s Right-to-Know Reports Earned standards. HAAs and TTHMs are by-products of a Grade of Good for 2000 and 2001 chlorine disinfection and may cause cancer and, potentially, reproductive and other health problems. The reports included much important information At levels measured in Philadelphia tap water, TTHMs and were generally well presented. and HAAs came in well above health goals and are The reports could have been more complete in their of potential health concern. discussions of sources of pollutants and health threats to consumers. Lead levels, although not in violation of EPA standards, were found in excess of the health goal and were cause Philadelphia Earned a Source Water Protection for concern—particularly in Philadelphia schools and Rating of Poor homes with young children. Lead—which enters drinking water supplies from the corrosion of pipes or The city’s water sources are threatened by contami- faucets—can adversely affect blood pressure, red blood nation from treated and untreated sewage, industrial cells, and kidney and nervous system function and, point sources, transportation accidents and spills, especially in infants and children, cause permanent urban, suburban, and agricultural runoff, acid mine brain damage, decreased intelligence, and problems drainage, and drought. Philadelphia has put a major with growth, development, and behavior. effort into assessing this pollution and is trying to encourage protection of its source water, but the city PHILADELPHIA does not control its watersheds, and the state does not adequately regulate pollution of these waters. System Population Served 1,600,0002 Water Quality and Compliance Noteworthy 2000 Fair 2001 Fair As of June 2001, the Philadelphia Water Department’s Right-to-Know Report—Citizenship projected capital budget is $150 million per year for 2000 Good 2001 Good drinking water, wastewater, and stormwater expendi- 3 Source Water Protection tures combined. Press accounts reported Philadelphia’s Poor drinking water capital improvement budget alone REPORT CARD to be $46 million per year.4 Reported planned capital 171 Natural Resources Defense Council improvements include rehabilitation of the sampling CRYPTOSPORIDIUM AND GIARDIA LEVELS lines at the Queen Lane Treatment Plant, improve- ments to operations, including aeration tanks at water 100 90 Philadelphia pollution control plants, storm flood relief, and replace- Crypto ment of 27 miles of water mains in Philadelphia 80 Giardia each year.5 In correspondence with NRDC, the city’s 70 water department forecast future capital budgets of 60 $50 million a year for treatment plant improvements, 50 including drinking water, wastewater, and biosolids 40 recycling, and $25 million per year for drinking water 30 6 % OF SAMPLES POSITIVE conveyance improvements. 20 10 0% 0% 0% 0 Finished Raw Finished Raw KEY CONTAMINANTS IN PHILADELPHIA’S Water Water Water Water WATER 2000 2001 The following contaminants have been found in Phila- delphia’s drinking water supply. For more information National Requirements on health threats posed by specific contaminants, see All large- and medium-size water utilities that use surface water must monitor for Crypto and Giardia, report results in their right- Chapter 5. to-know reports, and use advanced treatment if significant levels are found. MICROBIOLOGICAL CONTAMINANTS LEVELS PRESENT HIGH CONCERN Cryptosporidium and Giardia Cryptosporidium (Crypto) and Giardia are waterborne National Standard microbial disease-carrying pathogens that presents Treatment Technique (TT) health concerns, especially to individuals with weak- Draft Proposed New National Standard7 ened immune systems, including HIV/AIDS patients, <7.5 organisms/100 liters (average); no additional treatment 7.5–100 organisms/100 liters (average); some additional the elderly, children, and people who have undergone treatment (>90% Crypto kill) organ transplants. Under a negotiated EPA rule that is 100–300 organisms/100 liters (average); significant additional out in draft proposed form and is soon scheduled to be treatment (>99% Crypto kill) proposed formally in The Federal Register, water utilities >300 organisms/100 liters (average); advanced treatment (>99.7% Crypto kill) that find significant levels of Crypto will have to use National Health Goal (MCLG) more effective treatment to kill the pathogen. Existing 0—no known fully safe level rules require Giardia control as well. Philadelphia has National Requirements for Crypto now joined the EPA-industry “Partnership for Safe Most large- and medium-size water utilities that use surface water are required to monitor for Crypto and report results in Water” and reports that it has been keeping its their right-to-know reports; they eventually may be required to turbidity levels lower than required by EPA rules in use advanced treatment if significant levels are found. recent years, in an effort to increase the likelihood that 2000 Levels8 Crypto, Giardia, and other microbes are filtered out. Crypto in finished water: 0% of samples positive (0 of 36) Crypto in raw water: 20% of samples positive Total Coliform Bacteria Giardia in finished water: 0% of samples positive (0 in 36) Giardia in raw water: 73% of samples positive National Standard (MCL) 5% maximum in any month10 2001 Levels9 Crypto in finished water: 0% of samples positive (0 of 58) National Health Goal (MCLG) Crypto in raw water: 27% of samples positive 0—no known fully safe level Giardia in finished water: 2% of samples positive (1 in 58) 1999 Levels Giardia in raw water: 69% of samples positive 0.4% in highest month, total coliform positive11 172 What’s On Tap? 2000 Levels gastrointestinal illness, which often can be caused by 0.4% in highest month, total coliform positive12 water contamination.14,15 2001 Levels The first study, published in 1997, found that 0.9% in highest month, total coliform positive13 although the Philadelphia system was filtered and Total coliform bacteria are microbial contaminants in compliance with existing federal standards, emer- whose presence is a potential indicator that disease- gency room visits and admissions of children into causing organisms may be present in tap water. Coli- Children’s Hospital of Philadelphia for gastrointestinal form bacteria are occasionally found in Philadelphia’s illness spiked after a short lag time following spikes water but at levels well below the national standard. in turbidity levels in city tap water.16 The Harvard That said, the presence of any coliform in Philadelphia’s investigators found about a 10 percent increase in distribution system could indicate that regrowth of emergency room visits for gastrointestinal illness bacteria may be occuring in the city’s aging pipes. by children three years old or older, and a 6 percent Turbidity increase in visits by younger children. Actual hos- National Standards (TT) (in Nephelometric Turbidity Units, pital admissions for gastrointestinal illness increased or NTU) 31 percent for older children and 13 percent for Filtered water younger children after turbidity spikes. All associa- 0.5 NTU 95% of the time (through 2001) 0.3 NTU 95% of the time (effective in 2002) tions were statistically significant. A second study 1 NTU 100% of the time (effective in 2002) by the Harvard team found similar results for elderly Unfiltered water Philadelphians, based on 1992 to 1993 water quality 5 NTU maximum, 100% of the time data and Medicare records.17 They found a 9 percent 2000 Levels 0.14 NTU maximum increase in hospital admissions for gastrointestinal 2001 Levels illness among people over 65 shortly after a spike in 0.083 NTU maximum city water turbidity. Again, the increases in illness were LEVELS PRESENT SOME CONCERN statistically significant. Turbidity is a measure of the cloudiness of water and City water department officials dispute the Harvard is used as an indicator
Recommended publications
  • Total Organic Carbon (TOC) Guidance Manual
    September 2002 RG-379 (Revised) Total Organic Carbon (TOC) Guidance Manual Water Supply Division printed on recycled paper TEXAS COMMISSION ON ENVIRONMENTAL QUALITY Total Organic Carbon (TOC) Guidance Manual Prepared by Water Supply Division RG-379 (Revised) September 2002 Robert J. Huston, Chairman R. B. “Ralph” Marquez, Commissioner Kathleen Hartnett White, Commissioner Jeffrey A. Saitas, Executive Director Authorization to use or reproduce any original material contained in this publication—that is, not obtained from other sources—is freely granted. The commission would appreciate acknowledgment. Copies of this publication are available for public use through the Texas State Library, other state depository libraries, and the TCEQ Library, in compli- ance with state depository law. For more information on TCEQ publications call 512/239-0028 or visit our Web site at: www.tceq.state.tx.us/publications Published and distributed by the Texas Commission on Environmental Quality PO Box 13087 Austin TX 78711-3087 The Texas Commission on Environmental Quality was formerly called the Texas Natural Resource Conservation Commission. The TCEQ is an equal opportunity/affirmative action employer. The agency does not allow discrimination on the basis of race, color, religion, national origin, sex, disability, age, sexual orientation or veteran status. In compliance with the Americans with Disabilities Act, this document may be requested in alternate formats by contacting the TCEQ at 512/239-0028, Fax 239-4488, or 1-800-RELAY-TX (TDD), or by writing
    [Show full text]
  • Recommended Standards for Water Works 2007 Edition
    Recommended Standards for Water Works 2007 Edition Policies for the Review and Approval of Plans and Specifications for Public Water Supplies A Report of the Water Supply Committee of the Great Lakes--Upper Mississippi River Board of State and Provincial Public Health and Environmental Managers MEMBER STATES AND PROVINCE Illinois Indiana Iowa Michigan Minnesota Missouri New York Ohio Ontario Pennsylvania Wisconsin Published by: Health Research Inc., Health Education Services Division, P.O. Box 7126, Albany, NY 12224 (518)439-7286 www.hes.org Copyright © 2007 by the Great Lakes - Upper Mississippi River Board of State and Provincial Public Health and Environmental Managers This book, or portions thereof, may be reproduced without permission from the author if proper credit is given. TABLE OF CONTENTS FOREWORD POLICY STATEMENT ON PRE-ENGINEERED WATER TREATMENT PLANTS POLICY STATEMENT ON AUTOMATED/UNATTENDED OPERATION OF SURFACE WATER TREATMENT PLANTS POLICY STATEMENT ON BAG AND CARTRIDGE FILTERS FOR PUBLIC WATER SUPPLIES POLICY STATEMENT ON ULTRA VIOLET LIGHT FOR TREATMENT OF PUBLIC WATER SUPPLIES POLICY STATEMENT ON INFRASTRUCTURE SECURITY FOR PUBLIC WATER SUPPLIES POLICY STATEMENT ON ARSENIC REMOVAL INTERIM STANDARD - NITRATE REMOVAL USING SULFATE SELECTIVE ANION EXCHANGE RESIN INTERIM STANDARD - USE OF CHLORAMINE DISINFECTANT FOR PUBLIC WATER SUPPLIES INTERIM STANDARD ON MEMBRANE TECHNOLOGIES FOR PUBLIC WATER SUPPLIES PART 1 - SUBMISSION OF PLANS 1.0 GENERAL 1.1 ENGINEER’S REPORT 1.1.1 General Information 1.1.2 Extent of water works
    [Show full text]
  • Dissolved Organic Carbon (DOC) (For Private Water and Health Regulated Public Water Supplies)
    Dissolved Organic Carbon (DOC) (For Private Water and Health Regulated Public Water Supplies) What Is Dissolved Organic Carbon? Dissolved organic carbon (DOC) is a general description of the organic material dissolved in water. Organic carbon occurs as the result of decomposition of plant or animal material. Organic carbon present in soil or water bodies may then dissolve when contacted by water. This dissolved organic carbon moves with both surface water and ground water. Acknowledgement: How Does Dissolved Organic Carbon Get Into Water? Organic material (including carbon) results from decomposition of plants or animals. This Fact Sheet is one of a Once this decomposed organic material contacts water it may partially dissolve. series developed by an Interagency Committee with representatives from How Does Dissolved Organic Carbon Affect My Health? Saskatchewan Ministry of DOC does not pose health risk itself but may become potentially harmful when in Health, Regional Health combination with other aspects of your water. When water with high DOC is Authorities, Saskatchewan chlorinated, harmful byproducts called trihalomethanes may be produced (see Watershed Authority, SaskH2O factsheet on trihalomethanes). Trihalomethanes may have long-term Saskatchewan Ministry of effects on health and they should be considered when chlorinating drinking water Environment, Saskatchewan Ministry of Agriculture, high in DOC. According to Health Canada, the benefits of chlorinating drinking Agriculture and Agri-Food water are much greater than the health risks associated with chlorination by- Canada – PFRA and Health products such as trihalomethanes Canada. DOC can interfere with the effectiveness of disinfection processes such as Responsibility for chlorination, ultraviolet and ozone sterilization. DOC can also promote the growth of interpretation of the content of microorganisms by providing a food source.
    [Show full text]
  • Turbidity Analysis for Oregon Public Water Systems Water Quality in Coast Range Drinking Water Source Areas June 2010
    Report Turbidity Analysis for Oregon Public Water Systems Water Quality in Coast Range Drinking Water Source Areas June 2010 Last Updated: 06/29/10 By: Joshua Seeds DEQ 09-WQ-024 This report prepared by: Oregon Department of Environmental Quality 811 SW 6th Avenue Portland, OR 97204 1-800-452-4011 Contact: Joshua Seeds (503) 229-5081 [email protected] Turbidity Analysis for Oregon Public Water Systems Table of Contents Table of Contents .......................................................................................... i List of Figures .............................................................................................. iii List of Tables ............................................................................................... iiv List of Maps ................................................................................................. iiv Executive Summary ..................................................................................... 1 Introduction .................................................................................................. 2 Applicable Turbidity Standards for Water Quality ............................................... 2 Public Water System Evaluations....................................................................... 3 Methods .......................................................................................................................... 5 Definitions of terms........................................................................................................
    [Show full text]
  • Publication No. 17: Ozone Treatment of Private Drinking Water Systems
    PRIVATE DRINKING WATER IN CONNECTICUT Publication Date: April 2009 Publication No. 17: Ozone Treatment of Private Drinking Water Systems Effective Against: Pathogenic (disease-causing) organisms including bacteria and viruses, phenols (aromatic organic compounds), some color, taste and odor problems, iron, manganese, and turbidity. Not Effective Against: Large cysts and some other large organisms resulting from possible or probable sewage contamination, inorganic chemicals, and heavy metals. How Ozone (O3) Treatment Works Ozone is a chemical form of pure oxygen. Like chlorine, ozone is a strong oxidizing agent and is used in much the same way to kill disease-causing bacteria and viruses. It is effective against most amoebic cysts, and destroys bacteria and some aromatic organic compounds (such as phenols). Ozone may not kill large cysts and some other large organisms, so these should be eliminated by filtration or other procedures prior to ozone treatment. Ozone is effective in eliminating or controlling color, taste, and odor problems. It also oxidizes iron and manganese. Ozone treatment units are installed as point-of-use treatment systems. Raw water enters one opening and treated water emerges from another. Inside the treatment unit, ozone is produced by an electrical corona discharge or ultraviolet irradiation of dry air or oxygen. The ozone is mixed with the water whenever the water pump is running. Ozone generation units require a system to clean and remove the humidity from the air. For proper disinfection the water to be treated must have negligible color and turbidity levels. The system requires routine maintenance and an ozone treatment system can be very energy consumptive.
    [Show full text]
  • Raw Water Irrigation System Master Plan
    TOWN OF FIRESTONE RAW WATER IRRIGATION SYSTEM MASTER PLAN MARCH 2010 COLORADO CIVIL GROUP, INC. Raw Water Irrigation System Master Plan March 2010 Table of Contents 1 Introduction ............................................................................................................................................................................................. 1 1.1 Project Goals ................................................................................................................................................................................... 1 1.2 Scope of Work ................................................................................................................................................................................ 1 1.2.1 Existing Master Plan Evaluation ............................................................................................................... 1 1.2.2 Identifying Potential Areas for Raw Water Irrigation ............................................................................... 1 1.2.3 Irrigation Ditch Evaluation ........................................................................................................................ 1 1.2.4 Hydraulic Analysis and Calculations ......................................................................................................... 2 1.2.5 Raw Water System Modeling ................................................................................................................... 2 1.2.6 Raw Water Irrigation System Master
    [Show full text]
  • 21 Reverse Osmosis Treatment of PDWS 03-09
    PRIVATE DRINKING WATER IN CONNECTICUT Publication Date: March 2009 Publication No. 21: Reverse Osmosis Treatment of Private Drinking Water Systems Effective Against: inorganic contaminants such as: dissolved salts of sodium, dissolved (ferrous) iron, nitrate, lead, fluoride, sulfate, potassium, manganese, aluminum, silica, chloride, total dissolved solids, chromium, and orthophosphate. Also effective in removing some detergents, some taste, color and odor-producing chemicals, certain organic contaminants, uranium, and some pesticides. Not Effective Against: dissolved gases, most volatile and semi-volatile organic contaminants including some pesticides and solvents. Alone, reverse osmosis (RO) units are not recommended for treatment of bacteria and other microscopic organisms. How Reverse Osmosis Works A complete reverse osmosis system consists of a RO module, a storage tank, and a separate faucet. The module contains a semi-permeable membrane that allows water to selectively pass through and collect in the storage tank. The contaminants being treated by the RO unit are rejected and then washed off the membrane into a waste stream. It is not practical to treat all water entering a home with an RO system because about 75 percent of the water introduced is wasted. Thus, four gallons of raw water into the system produce about one gallon of treated water. This treated water comes out much slower than water from a regular tap, so a tank is used to store the treated water. The treated water is often used only for drinking and cooking. Each manufacturer’s RO units differ, but the time needed to produce one gallon of water ranges from 2-78 hours. The volume of wastewater produced by RO systems varies by make and model.
    [Show full text]
  • REVIEW of TURBIDITY: Information for Regulators and Water Suppliers
    WHO/FWC/WSH/17.01 WATER QUALITY AND HEALTH - TECHNICAL BRIEF TECHNICAL REVIEW OF TURBIDITY: Information for regulators and water suppliers 1. Summary This technical brief provides information on the uses and significance of turbidity in drinking-water and is intended for regulators and operators of drinking-water supplies. Turbidity is an extremely useful indicator that can yield valuable information quickly, relatively cheaply and on an ongoing basis. Measurement of turbidity is applicable in a variety of settings, from low-resource small systems all the way through to large and sophisticated water treatment plants. Turbidity, which is caused by suspended chemical and biological particles, can have both water safety and aesthetic implications for drinking-water supplies. Turbidity itself does not always represent a direct risk to public health; however, it can indicate the presence of pathogenic microorganisms and be an effective indicator of hazardous events throughout the water supply system, from catchment to point of use. For example, high turbidity in source waters can harbour microbial pathogens, which can be attached to particles and impair disinfection; high turbidity in filtered water can indicate poor removal of pathogens; and an increase in turbidity in distribution systems can indicate sloughing of biofilms and oxide scales or ingress of contaminants through faults such as mains breaks. Turbidity can be easily, accurately and rapidly measured, and is commonly used for operational monitoring of control measures included in water safety plans (WSPs), the recommended approach to managing drinking-water quality in the WHO Guidelines for Drinking-water Quality (WHO, 2017). It can be used as a basis for choosing between alternative source waters and for assessing the performance of a number of control measures, including coagulation and clarification, filtration, disinfection and management of distribution systems.
    [Show full text]
  • Guidelines for Drinking-Water Quality FIRST ADDENDUM to THIRD EDITION Volume 1 Recommendations WHO Library Cataloguing-In-Publication Data World Health Organization
    Guidelines for Drinking-water Quality FIRST ADDENDUM TO THIRD EDITION Volume 1 Recommendations WHO Library Cataloguing-in-Publication Data World Health Organization. Guidelines for drinking-water quality [electronic resource] : incorporating first addendum. Vol. 1, Recommendations. – 3rd ed. Electronic version for the Web. 1.Potable water – standards. 2.Water – standards. 3.Water quality – standards. 4.Guidelines. I. Title. ISBN 92 4 154696 4 (NLM classification: WA 675) © World Health Organization 2006 All rights reserved. Publications of the World Health Organization can be obtained from WHO Press, World Health Organization, 20 Avenue Appia, 1211 Geneva 27, Switzerland (tel: +41 22 791 3264; fax: +41 22 791 4857; email: [email protected]). Requests for permission to reproduce or translate WHO publications – whether for sale or for noncommercial distribution – should be addressed to WHO Press, at the above address (fax: +41 22 791 4806; email: [email protected]). The designations employed and the presentation of the material in this publication do not imply the expres- sion of any opinion whatsoever on the part of the World Health Organization concerning the legal status of any country, territory, city or area or of its authorities, or concerning the delimitation of its frontiers or boundaries. Dotted lines on maps represent approximate border lines for which there may not yet be full agreement. The mention of specific companies or of certain manufacturers’ products does not imply that they are endorsed or recommended by the World Health Organization in preference to others of a similar nature that are not mentioned. Errors and omissions excepted, the names of proprietary products are distinguished by initial capital letters.
    [Show full text]
  • 2020 Water Quality Report the City of New Philadelphia Water Department
    2020 WATER QUALITY REPORT THE CITY OF NEW PHILADELPHIA WATER DEPARTMENT Joel B. Day, Mayor Ron McAbier, Service Director Prepared by: 05/20/2021 Scott A. DeVault, Water Department Superintendent Scott A. DeVault Commitment to Quality The City of New Philadelphia is pleased to provide you, the water consumer, with our 2020 Water Quality Report. Results outlined in this report shows the City’s water does not contain any substances at levels that may be harmful to your health. We are proud to report that the drinking water we are supplying you with meets or exceeds all state and federal drinking water standards. As your water provider, we pride ourselves with providing our consumers safe drinking water of the highest quality available. The City of New Philadelphia has been providing water to the community for over 100 years. We are committed to furnishing the citizens of New Philadelphia quality potable water at a reasonable cost. For more information on your drinking water and/or this report, please contact Scott A. DeVault, Water Department Superintendent for the City of New Philadelphia at (330) 339‐2332. Report Information This report contains information on issues pertaining to the quality and supply of our drinking water including: • Water Source • Drinking Water Contents • Water Treatment Process • Water Quality Test Results • Special Health Concerns • Resources Available for Additional Information The Source of New Philadelphia’s Drinking Water The City of New Philadelphia obtains its drinking water from four wells screened in unconsolidated sand and gravel. The sources of drinking water both tap water and bottled water includes rivers, lakes, streams, ponds, reservoirs, springs, and wells.
    [Show full text]
  • Process Water Production from River Water by Ultrafiltration and Reverse Osmosis
    Process Water Production from River Water by Ultrafiltration and Reverse Osmosis M. Clever1, F.Jordt1,R.Knauf1,N.Räbiger2, M. Rüdebusch2, R. Hilker-Scheibel3 1 Axiva GmbH, Geb. G811, Industriepark Höchst, D 65926 Frankfurt Tel.: 069 / 305 16935, Fax: 069 / 30 90 14, E-Mail: [email protected] 2 Universität Bremen, 3 Stahlwerke Bremen GmbH 1. Abstract The new process for process water production from river water is divided into three stages: prefiltration, ultrafiltration and reverse osmosis. The latter technique has been state-of-the-art in the preparation of drinking water, boiler feed water and ultrapure water from conventionally pretreated raw water for many years. On the other hand, ultrafiltration is new to this sector and has only recently been used on the industrial scale. It is used as a single-stage process to purify drinking and process water as well as surface water as an alternative to conventional treatment processes (e.g. ozonization-precipitation-flocculation-coagulation-chlorination-gravel filtration). Multistage, fairly complex processes are employed in the conventional pretreatment of river water. The use of different chemicals necessitates special safety measures and careful harmonization and control of water chemistry in view of the requirements of downstream reverse osmosis. By contrast, processes based on membrane technology enable a simply designed plant to be used with several advantages. Axiva in cooperation with the water supply company for the Höchst Industrial Park have developed and successfully tested an efficient and cost-effective ultrafiltration process for river water in pilot-scale operation over several years. During this trial period low-energy systems based on different filtration concepts (cross-flow, dead-end), efficient hydrophilic membranes and a specific operating and backflushing technique specially designed for the application were employed.
    [Show full text]
  • New TU5 Series Process Turbidimeter for Raw Water Monitoring
    APPLICATION: TU5 FOR RAW WATER MONITORING New TU5 Series Process Turbidimeter For Raw Water Monitoring A long-term evaluation of applicability of a TU5300sc turbidimeter equipped with Automated Cleaning Module (ACM) for raw water monitoring was conducted at a surface water treatment plant in Colorado. The plant alternates between two water sources – reservoir and river water, with each source presenting different challenges. The reservoir water usually has a lower turbidity (~1-2 NTU), but undergoes seasonal inversion with rising manganese levels, which may cause the river water turbidity to vary wildly during summertime, when this source is used primarily. Due to high fouling capacity of source water, the use of ACM with TU5 series turbidimeters is mandatory for raw water monitoring. The goal of this study was to verify the new turbidimeter performance against a reference analyser (a Hach® 1720D) that had been working in this application for many years. Main parameters of the evaluation included direct com parison of the readings (logged every 15 minutes), maintenance requirements, and ability of the ACM equipped with a fiber wiper to keep the measurement cell clean. The ACM was set to clean the cell every 7 days routinely and when threshold of 3.5 NTU was exceeded. The test lasted for over 100 days and its results are presented in both graphical and numerical formats below. As seen in Figure 1 readings TU5 AMC Raw Water Test (fiber wiper) between two analysers trended well during the test on both reservoir and river TU5300-ACM, NTU 1720D RW, NTU water within a turbidity Auto-cleaning event span of 0.4 to 30.4 NTU.
    [Show full text]