GENERAL NOTES:

Moisture Vapour barrier or relevant 1. Do not scale Drawings. If drawings are in question or Noggins at 600mm centres max. impermeable wall underlay as per Noggins to comply with AS1684.2 (6.2.1.5) Moisture Vapour barrier or relevant discrepancy, the builder shall be responsible for obtaining impermeable wall underlay as per NCC and AS1684 Vertical installation is recommended to have fixings at 450mm maximum clarification from the building designer and or building NCC and AS1684 Timber at 600mm centres max. Timber or plastic shim spacer as appropriate (Min 10mm) Minimum H2 or Class 3 surveyor before continuing with construction. Vertical installation is recommended to Noggins to comply with AS1684.2 (6.2.1.5). have fixings at 450mm maximum Vertical installation is recommended to have fixings at 600mm 2. All dimensions relating to existing conditions shall be field maximum. 110mm SQE is recommended no more than 450mm verified. Noggins to comply with AS1684.2 (6.2.1.5). fixingTimber battens at 600mm centres max. Minimum H2 or Class 3. End cuts to be mitred and flush joined. Vertical installation is recommended to have fixings at 600mm maximum. End cuts to be mitred and flush joined. Cuts to be sealed with relevant sealer 110mm SQE is recommended no more than 450mm fixingTimber battens Cuts to be sealed with relevant sealer product as appropriate 3. Where otherwise specified all products shall be installed at 600mm centres max. Minimum H2 or Class 3. product as appropriate according to Radial Timbers specifications. This applies not withstanding any relevant Building Act, Regulation, Building Code of Australia, Local Government S03:A1/B1 S03:A1/B1 Regulation/Requirement and Australian Standard. Timber as per AS1684 Vertical Shiplap boards fixed to 4. Radial Timbers recommends the following gap spacing for horizontal timber battens V/Join Shiplap: as per Vertical Shiplap boards fixed to Typical Particleboard sheeting · 45mm & 70mm - 3mm Gap spacing S03:B2 AS1684 horizontal timber battens laid over timber floor · 90mm & 110mm - 5mm Gap spacing (See AS1860.2)

S03:A2 5. All external timbers to be treated against weather exposure End cuts to be sealed with relevant oil Typical timber floor End cuts to be sealed with relevant oil based sealer product as appropriate based sealer product as appropriate to current AS 1604 specifications or no less than durability Refer AS1684 Timber Typical timber bearer Class 1 In-Ground/Class 2 Above Ground as per AS 5604 Framing Manual for Span Termite cap on top of stump as per Timber Natural Durability Ratings. 150mm Min distance as per tables/sizes of timber NCC 3.1.3 Termite Management &

Typical polyethelene film 100 (NCC: 3.1.2.3) and/or (AS2870: 5.2.2) subfloor bearers/joists AS3600 Termite Management moisture barrier 6. All external steel & fixings to be a minimum of Hot Dip Typical Timber Barge Boards (See AS2870 for further details) Min sub floor height as per Height attached to cleat on side of stump Galvanized or equivalent corrosion protection to AS 2311 &

NCC 3.4.1 Sub Floor Ventillation. Min Height taken from bottom of bearer 2312 unless within 1Km from a salt water environment then to Ground Level (GL) Typical concrete stump Marine grade Stainless steel is to be used, except where

noted otherwise by the NCC. Fill

7. All Residential timber framing, bracing & tie downs are to be

S03:A - Vertical Shiplap Stud Frame - Fixing SOG Depth in accordance to AS 1684 (Commercial construction

1.0 1:15 Footing specifications to be provided by Engineer).

Stump & Footing size refer to: Overall Depth Depth AS1684 Timber Framing Manual &/or 8. Compliance with the relevant National Construction Code AS2870 Residential Slabs & Footings (or Engineers specifications where applicable) Of Australia (NCC) Volume 1 & or Volume 2 is mandatory Width (Not limited to) & the

12 13 12 GUIDE TO STANDARDS & TOLERANCES. Moisture vapour barrier or relevant Vertical fixed shiplap to be impermeable wall underlay as per mitred over batten and lapped S03:B - Vertical Shiplap Stud Frame: Batten Fixing - Timber Sub-Floor NCC & AS1684 as pictured 2.0 Typical plastic horseshoe packing 1:15 9. Compliance with the (NCC) Volume 1: Screw/ fixing as per Radial shim 10mm thickness. Packing shim Timber batten, size as appropriate. Timber Supplies product fixing 3.5.3.2 Timber Cladding & 3.5.3.6 Flashings

Timber battens at 600mm centres max. information specifications. 54 used for packing horizontal fixing Minimum H2 or Class 3 Fix board 10mm min clear of to wall openings 75 battens to alleviate and ventillate any joint. Openings in external wall cladding exposed to the weather Timber or plastic shim packer over moisture build up between moisture vertical stud, width as appropriate must be flashed as follows: stud size (Min 10mm thickness) vapour barrier and timber cladding End cuts to be mitred and flush (a) All openings must be adequately flashed using materials joined. Cuts to be sealed with relevant sealer product as that comply with AS/NZS 2904. appropriate 10 37 (b) Flashings must be securely fixed at least 25 mm under the cladding S03:A1 - Vertical Shiplap Mitre Join Typical Plastic Packer Timber or plastic shim spacer as 1.1 3.0 appropriate (Min 10mm) 1:5 Moisture vapour barrier or 10. Compliance with the following Australian Standards is relevent impermeable wall Typical timber batten as appropriate underlay as per NCC mandatory (Not limited to):

Typical timber frame stud AS 1684 TIMBER FRAMED CONSTRUCTION 35 Typical timber packing shim 10mm AS 5604 NATURAL TIMBER DURABILITY End cuts to be sealed Typical Particleboard sheeting with relevant oil based thickness. Packing shim used for Fixing as appropriate AS 3959 CONSTRUCTION IN BUSHFIRE AREAS sealer product as (See NCC Vol 1: 3.5.3.2 Timber Cladding) appropriate. packing horizontal fixing battens to and Radial Timber fixing recommendations AS 2796.1 TIMBER HARDWOOD - alleviate and ventillate any moisture (www.radialtimbers.com.au) Optional: SAWN & MILLED PRODUCTS Bottom side of board to build up between moisture vapour 0 75 (PRODUCT SPECIFICATION) be undercut min 15 barrier and timber cladding. Refer AS1684 Timber Framing Manual for Span angle to form drip edge tables/sizes of timber subfloor bearers/joists AS 2047 WINDOWS IN BUILDINGS on vertical fixed boards. This can easily docked by customer AS 2870 RESIDENTIAL SLABS & FOOTINGS Cladding to be min

50 from studs, etc; AS 1250 THE USE OF STEEL IN STRUCTURES 50mm past Floor Level End cuts to be sealed with relevant oil based sealer product as appropriate. 10 35 Typical timber joist AS 4100 STEEL STRUCTURES Flashing as appropriate Optional: Bottom side of board to be undercut min 150 AS 2311 PAINTING OF BUILDINGS angle to form drip edge on vertical fixed boards. Typical timber bearer 50 Cladding to be min 50mm past Floor Level AS 3600 TERMITE MANAGEMENT S03:A2 - Vertical Shiplap Bottom Flashing Typical Timber Packer AS 1170 STRUCTURAL DESIGN ACTIONS 1.2 4.0 Steel flashing as per (NCC:3.5.3.6) as appropriate 1:5 AS 1428 DESIGN FOR ACCESS AND MOBILITY Termite cap as per NCC 3.1.3 Termite Management & AS 1675 FIXED PLATFORMS, WALKWAYS, STAIRWAYS Typical Concrete or AS3600 Termite Management timber stump AND LADDERS - DESIGN, CONSTRUCTION AND INSTALLATION Typical Timber Barge Boards attached to cleat on side of stump 11. All underground services (Sewer, Drainage, Gas, Electric, telecommunications, etc;) to be determined on site & from relevant authority records, prior to commencement of any S03:B1 - Vertical Shiplap Detail construction. IMPORTANT: 2.1 Refer to Radial Timber Product specifications for further fixing information: 1:5 www.radialtimbers.com.au NOTE: Radial Timber Product specifications noted here-in are manufacturers information for guidance NOTES: DRAWING NAME: purposes only. Adherance with applicable Building Acts, Building Regulations, THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND RADIAL TIMBER SALES National Construction Codes, Local Government Regulations/Planning, Australian Standards NOTIFY ALL ERRORS AND OMISSIONS TO THE DESIGNER. 12 PARK DRIVE, Radial Shiplap Batten Fixing Details must take precedence. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL DANDENONG SOUTH 3175 ISSUED BY THE DESIGNER FOR CONSTRUCTION. PH: (03) 9768 2100 SCALE: A2 - Not To Scale DWG NO: S03 NOTE: DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. FAX: (03) 9768 2177 DATE: 6/07/2016 REVISION: 03 Termite Treatment in accordance with AS3600 required. FIXING DETAILS: EMAIL: [email protected] Installer to comply with AS3959 - Construction In Bushfire areas. REFER TO RADIAL TIMBERS RECOMMENDED FIXINGS WEB: www.radialtimbers.com.au (www.radialtimbers.com.au) GSPublisherEngine 0.2.100.100