Security Systems

From Our Reference Tel Fax Grasbrunn STDN/PRM Martin Herold Oct 2011

No. 1.2

Recipient RSOs, BU CCTV, Tech support, BRS customers Cc

Bosch Recording Station 8.9 Release Notes

Bosch Recording Station

Version 8.9

Release Notes

Overview

1 New software features in BRS 8.9...... 2 2 Fixed defects / resolved customer complaints...... 4 3 Known restrictions ...... 5

Page 1 of 6

Security Systems

From Our Reference Tel Fax Grasbrunn STDN/PRM Martin Herold Oct 2011

No. 1.2

Bosch Recording Station 8.9 Release Notes

1 New software features in BRS 8.9

1.1 Support of 64 cameras The maximum number of supported IP cameras is extended to 64. A new Expansion License for 32 cameras is introduced: BRS-XCAM-32A (F.01U.246.333) Expansion License 32 IP cameras

Existing BRS systems can be upgraded to max. 64 cameras with 1x BRS- XCAM-32A expansion license or 8x BRS-XCAM-04A expansion licenses.

Note: 64 cameras and 100 Mbps are only supported on server platforms following the recommended (or better) hardware specifications in BRS data sheet.

1.2 Supported 64 bit versions BRS 8.9 supports 64 bit Operating System versions of   Windows Server 2008 R2

1.3 Digital I/O module support BRS 8.9 supports the following ADAM I/O modules:

Inputs Relays ADAM 6017 0 2 ADAM 6018 0 8 ADAM 6022 2 2 ADAM 6024 2 2 ADAM 6050 12 6 ADAM 6050-W 12 6 ADAM 6051 12 2 ADAM 6051-W 12 2 ADAM 6052 8 8 ADAM 6055 18 0 ADAM 6060 6 6 ADAM 6060-W 6 6 ADAM 6066 6 6

Max. 8 I/O modules are supported per BRS.

All configured inputs and relays can be used in BRS application like any other input or relay (e.g. of IP cameras and encoders) Page 2 of 6

Security Systems

From Our Reference Tel Fax Grasbrunn STDN/PRM Martin Herold Oct 2011

No. 1.2

Bosch Recording Station 8.9 Release Notes

1.4 NetLimiter working on Windows 7 / Server 2008 Bandwidth limitation and UDP tunneling now also work on Windows 7 and Windows Server 2008.

1.5 New software features for bank market

1.5.1 Automatic log-off Protection against not authorized access: The active user can be automatically logged out after a configurable time interval of inactivity.

Note: If a BRS dialog (e.g. logbook search, motion search, export...) or the Configuration is open, BRS does not log off automatically.

1.5.2 Different alarm jobs per camera For bank applications there is a need for 2 different pre- and post-alarm times for 2 different events for 1 and the same camera. This feature is implemented in BRS 8.9.

Notes: Same stream settings on all jobs of this camera! Different pre-/post- alarm recording settings possible. Audio can be configured per job.

1.5.3 Alternative licensing model (USB dongle) An alternative licensing model for banking market is implemented in BRS 8.9. A USB dongle (CTN BRS-DNGL-A) will become available soon. For special cases when the customer wants to be hardware independent we offer an USB dongle that provides a unique Computer Signature (Dongle ID).

Note: A BRS dongle does not include licenses or activations. BRS still must be licensed via a software authorization and SLMS.

This USB dongle also can be used in case the Computer Signature changes on every start of BRS caused by e.g.  RAID (which covers / alters the HDD IDs or provides an own – mostly cryptically – hardware ID)  Windows 7 / Server 2008 which shows only these MACs which are actually connected  Different Windows users which have different permissions to access PC hardware

Page 3 of 6

Security Systems

From Our Reference Tel Fax Grasbrunn STDN/PRM Martin Herold Oct 2011

No. 1.2

Bosch Recording Station 8.9 Release Notes

1.6 Further software features

1.6.1 Improved configuration for Authorisation levels On new Authorisation levels the user can multi-select cameras and enable / disable permissions for complete columns for live and playback.

1.6.2 Connection type TCP for BVIP devices A registry key is available that enables BRS to change the connection type between the BVIP devices and BRS from UDP to TCP (for both MPEG4 and H.264 devices). This feature will be project released only and it cannot be configured in the user interface.

1.6.3 SNMP traps sending for cameras is configurable With BRS version 8.9 no SNMP traps for cameras are sent by default. The setting has to be turned on in the configuration as for inputs, relays and database. 2 Fixed defects / resolved customer complaints

2.1 Exit BRS application An user could exit the BRS application, although he is not allowed. This bug is fixed.

2.2 Improvement of PTZ control The PTZ control reacts more directly to the mouse inputs of an in window PTZ action (or UI Joystick control). The PTZ commands is no longer queued so that the camera does not keep moving after the mouse button has been released again.

2.3 ASF export from HD cameras ASF export from HD cameras was jumping, not all recorded frames were exported. This bug is fixed, now all frames are exported.

2.4 Reference image check and tamper detection for H.264 cameras Reference image check and tamper detection for H.264 cameras are now supported.

2.5 Print and Save image Print and Save image is now stretched according to their real aspect ratio. Page 4 of 6

Security Systems

From Our Reference Tel Fax Grasbrunn STDN/PRM Martin Herold Oct 2011

No. 1.2

Bosch Recording Station 8.9 Release Notes

2.6 32 Remote Stations for free BRS supports a maximum of 32 simultaneously connected Remote Stations at one Receiver Station for free. The licenses BRS-XREM-01A and BRS-XREM-04 become obsolete.

2.7 JobServer crash fixed A memory leak which could lead to JobServer crash was found and fixed. 3 Known restrictions

3.1 Windows 7 For loading and saving a configuration file (.PRM-file) Bosch Recording Station has to be started with elevated privileges in Windows Administrator mode.

3.2 .NET Framework 4.0 BRS 8.9 requires .NET Framework 4.0 to be installed. If not yet installed the user needs to install .NET Framework 4.0 manually before installing BRS 8.9.

Due to legal issue, we are not allowed to distribute .NET Framework 4.0 on Bosch web page or to put it on BRS 8.9 Setup DVD.

To download .NET Framework 4.0 (full install) from the Internet please use the following link: http://www.microsoft.com/downloads/details.aspx?FamilyID=0a391abd-25c1- 4fc0-919f-b21f31ab88b7

3.3 Installation Requirements for Operating Systems Please note the Installation Requirements for the different Operating Systems (also see BRS 8.9 Quick Installation Guide):

Windows 7 (32 bit / 64 bit)  .NET Framework 4 must be installed before installing BRS 8.9

Windows Server 2008 R2 (64 bit)  .NET Framework 4 must be installed,  Server feature Desktop Experience must be activated, and  Server feature .NET Framework 3.5.1 Features must be activated

before installing BRS 8.9

Page 5 of 6

Security Systems

From Our Reference Tel Fax Grasbrunn STDN/PRM Martin Herold Oct 2011

No. 1.2

Bosch Recording Station 8.9 Release Notes

Windows Server 2008 (32 bit)  .NET Framework 4 must be installed,  Server feature Desktop Experience must be activated, and  Server feature .NET Framework 3.0 Features must be activated before installing BRS 8.9

Windows XP Professional / Windows Server 2003 (32 bit)  .NET Framework 4 must be installed before installing the BRS 8.9

3.4 No ONVIF support ONVIF cameras are not yet supported in BRS version 8.9

3.5 Windows error message during Setup On Windows Server 2008 during Setup a message box with yellow bar may appear "User Account Control: An unidentified program wants access to your computer". To fix this, download and install the latest Root Certificate Update. Systems patched through Windows Update will receive this update automatically.

3.6 BRS Web Server The BRS Web Server does not work on Windows Server 2003 SP2 and Windows Server 2003 R2.

3.7 OPC Server The DiBos 8.7 OPC Server is not supported on Windows7 / Server 2008. The needed .NET Framework 1.1 cannot be installed on these Operating Systems.

STDN/PRM

Page 6 of 6