Laboratory Supplies

Total Page:16

File Type:pdf, Size:1020Kb

Laboratory Supplies ® Laboratory Supplies Beakers: 9 - 12 • Beakers with Handles • Square Ratio Beakers • Griffin Style Molded Beakers • Printed Square Ratio Beakers • Tapered Molded Beakers • Tapered Printed Beakers • Tapered PTFE Beakers • Heatable PTFE Beakers Tapered Low Form Beakers Page 10 Bottles: 20 - 37 • Plastic Laboratory Bottles • Polycarbonate Square Bottles • Rectangular Plastic Bottles • Tamper Evident Plastic Bottles • Concertina Collapsible Bottle Jars with • Plastic Dispensing Bottles Seal Inserts Page 38 • Plastic Wash Bottles • PTFE Bottle Pourers Containers: 38 - 42 • Screw Cap Plastic Jars & Containers • Snap Cap Plastic Jars & Containers • Hinged Lid Plastic Containers • Dispensing Plastic Containers • Graduated Plastic Containers • Disposable Plastic Containers • Sterile Plastic Containers NEW Multi-lingual Wide Mouth Wash Bottles Page 30 • Non-Pyrogenic Sterile Plastic Containers Cylinders: 45 - 48 • Clear Plastic Cylinder, PMP • Translucent Plastic Cylinder, PP • Short Form Plastic Cylinder, PP • Four Liter Plastic Cylinder, PP • Certified Plastic Cylinder, PMP • Hydrometer Jar, PP • Conical Shape Plastic Cylinder, PP Printed Cylinders Page 47 Drying Racks: 55 - 56 • Kartell Plastic Drying Rack, High Impact PS • Dynalon Mega-Peg Plastic Drying Rack • Azlon Epoxy Coated Drying Rack • Plastic Draining Baskets • Custom Size Drying Racks Available Drying Rack Holder Page 55 Dynalon® Labware ® Table of Contents and Introduction Dynalon Labware, a leading wholesaler of plastic lab supplies throughout North America, is the wholesale division of Dynalab Corp. Founded in 1957, Dynalon Labware is proud to be your supplier of choice for over 50 years. 2 Catalog Introduction 55 - 56 Drying Racks 79 - 80 Scoops 2 - 7 Technical Plastic Properties 56 Evaporating Dishes 80 - 81 Shields 8 Bags & Bag Ties 56 Eye Wash Station 81 - 83 Slide accessories 9 - 12 Beakers 57 - 59 Flasks 84 Spatulas - Spigot - Sponge 13 - 17 Beta Radiation Protection 60 Forceps 85 Spot Plates 17 - 32 Bottles and accessories 60 - 63 Funnels 85 - 90 Stirring Bars and Accessories 32 Bucket, Ice 63 Gamma Protection Products 90 Stirrers - Stopcocks 33 Burettes 64 Glass Sleeves - Hydrometers 91 Swabs - Tape 34 - 37 Carboys 64 Imhoff, Innoculating 91 - 92 Tote Boxes 38 Clamps 65 - 66 Labels 93 - 94 Trays 38 - 42 Containers 67 Matting 94 - 95 Tubes 42 Crucibles 68 Melting Point Apparatus 96 - 99 Tube Racks 43 Cutting Boards 68 - 69 Paddles 99 - 102 Tubing and accessories 43 - 45 Cuvettes and accessories 69 - 70 Pails 102 Tweezers 45 - 48 Cylinders and accessories 70 Parafilm Dispenser - Petri 103 Vials 48 Delivery Tubes 71 Pipettes 103 - 104 Vial Racks 49 - 50 Desiccators 72 - 73 Pipette Accessories 104 Watch Glass - Water Still 50 Detergent 73 Pipette Tips 105 Weighing Bottles 50 Dippas® 74 - 75 Pipettors & Accessories 105 - 106 Wipe & Wipe Dispensers 51 Dippers 76 Plates - Pump 107 - 110 Index 52 - 53 Dipping Baskets 77 Racks 111 - 112 Custom Plastic Fabrication 54 Disposal Boxes 78 - 79 Sample Cups - Samplers Labware Starter Kit This versatile pack contains over 45 safe and popular plastic labwar e products for young scientists especially in Elementary, Middle and High schools. Teach storage, measurement, pipeting, dispensing etc. in both English and metric. Duplicate products allow sharing amongst students. Item Polymer Description Quantity 237755 PMP Transparent Economy Molded Cylinder, 50mL 1 237765 PMP Transparent Economy Molded Cylinder, 100mL 1 237775 PMP Transparent Economy Molded Cylinder, 250mL 1 226415-0070 HDPE Cylindrical Jar with Screw Closure & Insert, 70mL 1 226415-0500 HDPE Cylindrical Jar with Screw Closure & Insert, 500mL 1 226415-1000 HDPE Cylindrical Jar with Screw Closure & Insert, 1000mL 1 259845 HDPE Test Tube Rack, Two Tier, for up to 18mm Tubes 1 262175 LDPE Droppers, Bellow-Type Bulb, 1.5mL 5 262185 LDPE Droppers, Bellow-Type Bulb, 5.0mL 5 299334-000B PP/LDPE Test Tube/Centrifuge Tube, Blue Closure, 16mm 2 299334-000R PP/LDPE Test Tube/Centrifuge Tube, Red Closure, 16mm 2 299334-000W PP/LDPE Test Tube/Centrifuge Tube, White Closure, 16mm 2 299334-000Y PP/LDPE Test Tube/Centrifuge Tube, Yellow Closure, 16mm 2 412575 NYL Spatula/Stirrer 10" 3 426364-07 PS Transparent Container w/ Snap-on Cap, 7Dram/24mL 3 501505-0125 PP Graduated Bottle Wide Mouth w/ Marking Area, 125mL 1 501505-0250 PP Graduated Bottle Wide Mouth w/ Marking Area, 250mL 1 502754-02 PS Pipette Graduated 2mL 5 506805-0250 LDPE Wash Bottle Narrow Mouth Sloped w/ White Clsr 250mL 1 522085-0100 PP Printed “Square Ratio” Beaker, 100mL 1 522085-0250 PP Printed “Square Ratio” Beaker, 250mL 1 326495-0500 PP Beaker with Handle, 500mL 1 537835-0100 PP Graduated Cylinder w/ Graduations, Squat Form, 100mL 1 542365-04 PP Lightweight Funnels, 50mm ID 1 605085-0005 LDPE Dispensing Bottle 15mL 1 605085-06 LDPE Dispensing Bottle 180mL 1 Lab Starter Pack Labware Starter Pack $97.00 each Copyright Dynalab Corp. 2015 and earlier. quality . value . service 1 Plastics properties& LDPE (Low Density Polyethylene) HDPE (High Density Polyethylene) Introduction • Translucent naturally • Translucent rigid polymer flexible polymer • Temperature range of ® The Dynalon catalog technical • Temperature range of -100 to +120ºC section aims to provide clear, concise information about the -50 to +80ºC • Not autoclavable key polymers from which our • Not autoclavable • Good to excellent chemical ranges are manufactured. It is • Good to excellent chemical resistance intended as your guide to the resistance • High impact resistance suitability of our products for use with a variety of chemical • Robust and virtually unbreakable • Used for storage bottles, groups, and in a variety of • Used for wash bottles, storage containers and jars environments. bottles, transfer pipettes, vials Excellent resistance (no attack) Each polymer has its own entry Excellent resistance (no attack) to dilute and concentrated Acids, with detailed technical information and a summary to dilute and concentrated Acids, Alcohols and Bases. icon denoting its general Alcohols, Bases and Esters. Good resistance (minor attack) chemical suitability Good resistance (minor attack) to Aldehydes, Esters, Aliphatic and characteristics. Those Polymers capable of being repeatedly to Aldehydes, Ketones and Aromatic Hydrocarbons, Ketones Autoclaved at, at least 121°C Vegetable Oils. and Mineral and Vegetable Oils. for 30 minutes are denoted by Limited resistance (moderate Limited resistance (moderate the letter A, more detailed temperature resistance is often attack suitable for short term use attack and suitable for short term included in the text. only) to Aliphatic and Aromatic use only) to Halogenated Hydrocarbons, Mineral Oils and Hydrocarbons and Oxidizing The information within this Oxidizing Agents. Agents. section is designed to answer most common application Poor resistance and not questions but like any guide recommended for use with quick facts will not answer all. Dynalon's Halogenated Hydrocarbons. Maximum Temperature: Technical Department will be pleased to answer any 248°F (120°C) question relating to quick facts Minimum Temperature: product usage. Maximum Temperature: -148°F (-100°C) 176°F (80°C) Autoclavable: No Minimum Temperature: UV Resistance: Poor -58°F (-50°C) Translucent and Rigid Autoclavable: No Recycling Code: 2 UV Resistance: Poor Translucent with Excellent flexibility HDPE Recycling Code: 4 LDPE 2 Dynalon® Labware chemical resistance PP (Polypropylene) PMP (Polymethylpentene) PS (Polystyrene) • Translucent rigid polymer • Transparent rigid polymer • Transparent rigid polymer • Temperature range • Temperature range • Temperature range 0 to +135ºC 0 to +145ºC -10 to +70ºC • Autoclavable (repeatedly) • Autoclavable • Not autoclavable • Good to excellent chemical • Good to excellent chemical • Moderate chemical resistance resistance resistance • Brittle yet has excellent clarity • Impact resistant • Glass like clarity • Used for petri dishes, pipettes • Used for beakers, bottles, • Used for transparent beakers and container ware cylinders and screw closures and cylinders Excellent resistance (no attack) Excellent resistance (no attack) Excellent resistance (no attack) to dilute Acids, Alcohols and to dilute and concentrated Acids, to dilute and concentrated Acids, Mineral Oils. Alcohols, Bases and Mineral Oils. Alcohols, Bases and Mineral Oils. Good resistance (minor attack) Good resistance (minor attack) Good resistance (minor attack) to Vegetable Oils. to Aldehydes, Esters, Aliphatic to Aldehydes, Esters, and Limited resistance (moderate Hydrocarbons, Ketones & Vegetable Vegetable Oils. attack and suitable for short Oils. Limited resistance (moderate term use only) Limited resistance (moderate attack and suitable for short term to concentrated Acids. attack and suitable for short term use only) to Aliphatic and Poor resistance not recom- use only) to Aromatic and Aromatic Hydrocarbons, Ketones mended for use with Aldehydes, Halogenated Hydrocarbons and and Oxidizing Agents. Esters, Aliphatic, Aromatic and Oxidizing Agents. Poor resistance not Halogenated Hydrocarbons, recommended for use with Ketones and Oxidizing Agents. quick facts Halogenated Hydrocarbons. Maximum Temperature: quick facts 275°F (135°C) quick facts Maximum Temperature: Minimum Temperature: Maximum Temperature: 158°F (70°C) 32°F (0°C) 293°F (145°C) Minimum Temperature: Autoclavable: Yes Minimum Temperature: 32°F (0°C) UV Resistance: Poor 32°F (0°C) Autoclavable: No Translucent and Rigid Autoclavable: Yes UV Resistance: Good Recycling Code: 5 UV Resistance:
Recommended publications
  • PP003: Large Scale Growth of M. Tuberculosis
    SOP: PP003.2 Modified: 6/10/2010 Large-scale growth of Mycobacterium tuberculosis Materials and Reagents: 1. Biosafety cabinet (BSC) 2. Three 100 ml frozen stocks of M. tuberculosis (see SOP PP002) 3. Eight 2.8 L glass fernbach flasks containing 900 ml sterile GAS medium, capped with cotton and cheesecloth plugs wrapped in aluminum foil 4. Orbital platform shaker 5. Four 50 ml disposable pipets 6. Electric pipetter 7. Bunsen burner 8. Pipet boat 9. 10% Lysol I. C. solution 10. Autoclave 11. Forty 1 liter rollerbottles containing 400 ml sterile GAS medium 12. Two 25 ml disposable pipets 13. Rollerbottle apparatus 14. Rubbermaid transport cart 15. Vacuum pump 16. Five 4 liter Winchester bottles, sterile 17. Five 0.2 um Zap Cap S plus bottle filtration units 18. 225 ml Falcon centrifuge bottle 19. 225 ml centrifuge bottle rack 20. Harvard trip balance 21. Sorvall benchtop centrifuge 22. Sorvall benchtop centrifuge rotor, containing 225 ml centrifuge bottle hanging buckets 23. Sterile Milli-Q water 24. 4oC cold room (BHRB Molecular Biology room 101) 25. –80oC freezer (option, note 17) Upscale protocol: (note 1) 1. _____ Inside a biosafety cabinet in a BSL-3 facility, thaw three “100 ml” stocks of M. tuberculosis. 2. _____ Carefully pour the contents of one stock into one 2.8 L fernbach flask containing GAS medium. 3. _____ Flame opening and aseptically replace foil and cotton plug in mouth of the fernbach flask. 4. _____ Repeat for two remaining “100 ml” stocks. 5. _____ Place the inoculated fernbach flasks on an orbital platform shaker at 37oC for two weeks (notes 2 and 3).
    [Show full text]
  • Catalogue of Chemical, Philosophical and Other Glassware For
    CHEMICAL GLASSWARE. PHILADELPHIA & NEW YORK 1 8 8 1 1 8 8 1 CATALOGUE OF CHEMICAL, PHILOSOPHICAL AN D OTHER GLASSWARE FOR LABORATORIES, COLLEGES, MUSEUMS, ASSAYING WORKS, INSTITUTES OF TECHNOLOGY, ACADEMIES, &c., &c. MANUFACTURED BY WHITALL, TATUM & CO., No. 410 RACE STREET, 46 and 48 BARCLAY ST., P. O. Lock Box P, P. O. Box 3814, PHILADELPHIA. N E W Y O R K . 1 8 8 1 . For a full line of G lassw are of various kinds, send for our G eneral C atalogue. CHEMICAL REAGENTS AT NET PRICES. Discount on Chemical List, pages vi.-xiv., and Bottles, x v i i i . - x x . , .................................................................................45 p e r cent. Discount on Flint Homoeopathic Vials, pages xxi.-xxiii., 25 “ “ Graduates, pages xvi., xvii., - - 25 “ Reagents, pp. iv., v.; Sundries, p. xv.; and Scales, p. xxiv. at net prices. The references by pages are to oar GENERAL CATALOGUE. ii CHEMICAL AND PHILOSOPHICAL GLASSWARE FOR Laboratories, Colleges, Museums, Assaying Works, Institutes of Technology, Academies, &c. Attention is invited to the Line of Chemical Glass Ware of our own manufacture. By purchasing this class of goods at home, instead of depending upon foreign sources of supply, the carrying of a large and expensive stock is avoided; the opportunity of effecting changes in the form of apparatus for special purposes is afforded, and promptness in filling orders greatly facilitated. Under the advice and direction of experienced chemists, we have for a number of years been perfecting our work in these lines, and now feel confident that the character both of the glass and work­ manship will be found, for all the usual needs of the Laboratory, to compare favorably with the imported wares.
    [Show full text]
  • Laboratory Glassware N Edition No
    Laboratory Glassware n Edition No. 2 n Index Introduction 3 Ground joint glassware 13 Volumetric glassware 53 General laboratory glassware 65 Alphabetical index 76 Índice alfabético 77 Index Reference index 78 [email protected] Scharlau has been in the scientific glassware business for over 15 years Until now Scharlab S.L. had limited its sales to the Spanish market. However, now, coinciding with the inauguration of the new workshop next to our warehouse in Sentmenat, we are ready to export our scientific glassware to other countries. Standard and made to order Products for which there is regular demand are produced in larger Scharlau glassware quantities and then stocked for almost immediate supply. Other products are either manufactured directly from glass tubing or are constructed from a number of semi-finished products. Quality Even today, scientific glassblowing remains a highly skilled hand craft and the quality of glassware depends on the skill of each blower. Careful selection of the raw glass ensures that our final products are free from imperfections such as air lines, scratches and stones. You will be able to judge for yourself the workmanship of our glassware products. Safety All our glassware is annealed and made stress free to avoid breakage. Fax: +34 93 715 67 25 Scharlab The Lab Sourcing Group 3 www.scharlab.com Glassware Scharlau glassware is made from borosilicate glass that meets the specifications of the following standards: BS ISO 3585, DIN 12217 Type 3.3 Borosilicate glass ASTM E-438 Type 1 Class A Borosilicate glass US Pharmacopoeia Type 1 Borosilicate glass European Pharmacopoeia Type 1 Glass The typical chemical composition of our borosilicate glass is as follows: O Si 2 81% B2O3 13% Na2O 4% Al2O3 2% Glass is an inorganic substance that on cooling becomes rigid without crystallising and therefore it has no melting point as such.
    [Show full text]
  • 7. Heating and Cooling Technology Contents
    GENERAL CATALOGUE EDITION 18 7. Heating and cooling technology Contents Cooling 730 Refrigerators and Freezers ex protected 730 Refrigerators and Freezers 733 Low and Ultra low temperature freezers 737 Ice machines 744 Cryogenic tubes 746 Cryogenic boxes 749 Cryogenic racks 756 Cryogenic accessories 757 Transport boxes 759 Dewar flasks 760 Cryogenic storage tanks 763 Liquid nitrogen-Accessories 766 Temperature regulators 767 Heating-Thermostats 767 Cooling-Thermostats 779 Circulator baths 787 Dynamic Temperature Control Systems 791 Temperature Control Accessories 794 Heating 798 Water baths 798 Shaking water baths 805 Heating baths 810 Microwaves 814 Universal, Heating and Drying incubators 815 Vacuum drying incubators 819 Incubators 821 Cooling incubators 825 CO2-Incubators 829 Shaking incubators 833 Test incubators 847 Ovens, Furnaces 854 Hotplates 858 Incubation hoods 863 Temperature controllers, thermostats 868 729 www.wenk-labtec.com 7. Heating and cooling technology GENERAL CATALOGUE EDITION 18 Cooling/Refrigerators and Freezers ex protected 1 Spark-free laboratory refrigerators The BGR 120 laboratory guidelines state that interiors of refrigerators in which AQUALYTIC dangerous, explosive atmospheres can develop, must be spark-free. Such explosive atmospheres can be created by stored flammable liquids, for example. The laboratory refrigerators by Aqualytic® meet these requirements. The interiors are free from sparking sources and are therefore explosion-proof. With glass shelves. Variable temperature control from +2°C to +10°C. Temperature is continuously controlled by thermostat. Capacity External Internal Weight Power Temp. PK Cat. No. dimensions dimensions range (W x D x H) (W x D x H) LmmmmkgW°C 150 602 x 600 x 885 515 x 443 x 700 37.00 120 +2 ..
    [Show full text]
  • Uv and Visible Spectroscopy1
    Page 1 of 4 I. INTRODUCTION TO UV AND VISIBLE SPECTROSCOPY1 When white light passes through or is reflected by a colored substance, a characteristic portion of the mixed wavelengths is absorbed. The remaining light will then assume the complementary color to the wavelength(s) absorbed. Thus, absorption of 420-430 nm light renders a substance yellow, and absorption of 500-520 nm light makes it red. Green is unique in that it can be created by absorption close to 400 nm as well as absorption near 800 nm. When sample molecules are exposed to light having an energy that matches a possible electronic transition within the molecule, some of the light energy will be absorbed as the electron is promoted to a higher energy orbital. An optical spectrometer records the wavelengths at which absorption occurs, together with the degree of absorption at each wavelength. The resulting spectrum is presented as a graph of absorbance (A) versus wavelength. Absorbance usually ranges from 0 (no absorption) to 2 (99% absorption), and is precisely defined in context with spectrometer operation. Because the absorbance of a sample will be proportional to the number of absorbing molecules in the spectrometer light beam (e.g. their molar concentration in the sample tube), it is necessary to correct the absorbance value for this and other operational factors if the spectra of different compounds are to be compared in a meaningful way. The corrected absorption value is called "molar absorptivity", and is particularly useful when comparing the spectra of different compounds and determining the relative strength of light absorbing functions (chromophores).
    [Show full text]
  • EXPERIMENT 15 TF Notes
    EXPERIMENT 15 TF Notes 1. Have students log onto LoggerPro3 and start heating water as soon as they arrive 2. This reaction is easily contaminated so students must never insert the thermometer directly into the cuvette containing the reaction. Instead they should rather measure the temperature of the water and equate that to the temperature of the solution in the cuvette. 3. We will be using hot gloves in this experiment. 4. Make sure you are familiar with the calculations necessary to fill out the chart. All the necessary equations are given at the top fo the page. Note that the temperature must be converted from °C to K. EXPERIMENT 15 Thermodynamics of Complex-Ion Equilibria Introduction Thermodynamic data for a reaction system provides researchers with information that is important from both theoretical and practical points of view. There are several thermodynamic properties that chemists pay close attention to when designing or carrying out experiments such as thermodynamic stability, the change in free energy of a reaction, and temperature dependence. For example, if a chemist wants to create a new type of solar cell that combines a semiconductor material with a novel conductive oxide and wants to make sure that the two materials will not react with each other, thermodynamics provide the answer. By finding the free energy change associated with the reaction, s/he can determine how stable the layers are in contact with each other and to what temperature. In this experiment, you will learn how to determine those parameters from a controlled experiment by using spectrometry to find concentration data at various temperatures.
    [Show full text]
  • Structural and Functional Studies of Membrane Remodeling Machines
    View metadata, citation and similar papers at core.ac.uk brought to you by CORE HHS Public Access provided by CDC Stacks Author manuscript Author ManuscriptAuthor Manuscript Author Methods Manuscript Author Cell Biol. Author Manuscript Author manuscript; available in PMC 2018 August 13. Published in final edited form as: Methods Cell Biol. 2015 ; 128: 165–200. doi:10.1016/bs.mcb.2015.02.007. Structural and Functional Studies of Membrane Remodeling Machines Raghav Kalia#1,2, Nathaniel Talledge#1,2, and Adam Frost1,2 1Department of Biochemistry, University of Utah, School of Medicine, Salt Lake City, UT 84112 2Department of Biochemistry and Biophysics, University of California, San Francisco, San Francisco, CA 94158 # These authors contributed equally to this work. Abstract Building cells from their component parts will hinge upon our ability to reconstitute biochemical compartmentalization and exchange between membrane-delimited organelles. By contrast with our understanding of other cellular events, the mechanisms that govern membrane trafficking has lagged because the presence of phospholipid bilayers complicates the use of standard methods. This chapter describes in vitro methods for purifying, reconstituting and visualizing membrane remodeling activities directly by electron cryomicroscopy (cryoEM). Keywords Membrane remodeling; electron cryomicroscopy; cryoEM; endocytosis; mitochondria; dynamin; endophilin; bilayer; lipid-binding Introduction to membrane remodeling Chemical compartmentalization was as critical in the evolution of life as was the realization of self-replicating molecules. Robert Hooke’s use of the metaphorical “cell” draws our attention to the inhabitants of the “small rooms” he observed with his microscope; but also to the walls that outline a room, distinguish it from its neighbors, and that segregate inside from outside activities (1).
    [Show full text]
  • Laboratory Equipment Reference Sheet
    Laboratory Equipment Stirring Rod: Reference Sheet: Iron Ring: Description: Glass rod. Uses: To stir combinations; To use in pouring liquids. Evaporating Dish: Description: Iron ring with a screw fastener; Several Sizes Uses: To fasten to the ring stand as a support for an apparatus Description: Porcelain dish. Buret Clamp/Test Tube Clamp: Uses: As a container for small amounts of liquids being evaporated. Glass Plate: Description: Metal clamp with a screw fastener, swivel and lock nut, adjusting screw, and a curved clamp. Uses: To hold an apparatus; May be fastened to a ring stand. Mortar and Pestle: Description: Thick glass. Uses: Many uses; Should not be heated Description: Heavy porcelain dish with a grinder. Watch Glass: Uses: To grind chemicals to a powder. Spatula: Description: Curved glass. Uses: May be used as a beaker cover; May be used in evaporating very small amounts of Description: Made of metal or porcelain. liquid. Uses: To transfer solid chemicals in weighing. Funnel: Triangular File: Description: Metal file with three cutting edges. Uses: To scratch glass or file. Rubber Connector: Description: Glass or plastic. Uses: To hold filter paper; May be used in pouring Description: Short length of tubing. Medicine Dropper: Uses: To connect parts of an apparatus. Pinch Clamp: Description: Glass tip with a rubber bulb. Uses: To transfer small amounts of liquid. Forceps: Description: Metal clamp with finger grips. Uses: To clamp a rubber connector. Test Tube Rack: Description: Metal Uses: To pick up or hold small objects. Beaker: Description: Rack; May be wood, metal, or plastic. Uses: To hold test tubes in an upright position.
    [Show full text]
  • Manual: Zetasizer Nano Accessories Guide
    ! www.malvern.com Zetasizer nano series Malvern Instruments Limited Printed in England MRK1378-01 Enigma Business Park Q & Grovewood Road, Malvern Worcs, WR14 1XZ, U.K. SelAccessories Guide Tel: +44 (0) 1684 892456 Fax: +44 (0) 1684 892789 Malvern Zetasizer Nano accessories guide MAN0487 Issue 1.1 April 2013 Copyright © 2007 - 2013 Malvern Instruments Ltd. Malvern Instruments pursues a policy of continual improvement due to technical development. We therefore reserve the right to deviate from information, descriptions, and specifications in this publication without notice. Malvern Instruments shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. No reproduction or transmission of any part of this publication is allowed without the express written permission of Malvern Instruments Ltd. Head office: Malvern Instruments Ltd. Enigma Business Park, Grovewood Road, Malvern, Worcestershire WR14 1XZ United Kingdom. Tel + [44] (0)1684-892456 Fax + [44] (0)1684-892789 Zetasizer, Malvern and the 'hills' logo are registered trademarks in the UK and/or other countries, and are owned by Malvern Instruments Ltd. NIBS and M3-PALS are trademarks of Malvern Instruments. M3 is granted Euro Pat No: 1 154 266 DE FR. Windows is a registered trademark of Microsoft Corporation. Tygon is a registered trademark of Saint-Gobain Corporation. Hellmanex is a registered trademark of Hellma GmbH & Co. KG. Table of contents Introduction and accessory range Introduction . 1-1 Accessory range. 1-1 General cells and cuvettes Introduction . 2-1 Cuvette holder . 2-2 Cell and cuvettes . 2-3 Size and molecular weight cuvettes .
    [Show full text]
  • New Brunswick Shakers Eppendorf and New Brunswick
    Eppendorf is your source for New Brunswick products New Brunswick Shakers Eppendorf and New Brunswick “In Touch with Life” Gets “A Culture of Innovation” New Brunswick’s world renowned Shakers, CO2 Incubators, Energy-efficient –86 °C ULT freezers are available in upright ULT Freezers and Fermentors/Bioreactors are now sold or chest configurations and feature two model ranges and through Eppendorf North America, in the US and Canada. 12 different sizes. Innova series freezers utilize space-saving vacuum insulation panels for increased internal capacity with The New Brunswick product line perfectly complements the a small footprint and Excella series utilize traditional insulation. Eppendorf product range of liquid handling, centrifugation, PCR, A standard feature found on all New Brunswick freezers is the sample prep, detection and cell biology instrumentation and built-in heated vent port to release vacuum after the door is shut consumables. to gain easy access to samples. New Brunswick Shakers With 3 product lines to choose from, Innova, I-Series or Excella series, there’s a shaker suited to your exact needs and budget. The world famous, reliable, triple-eccentric drive mechanism with cast iron top plate, found in the Innova and I-series, provides decades worth of durability. Shakers sold in the 1950’s are still going strong today. Every New Brunswick shaker drive is individually CAM’d for precise tolerances and dependability for years of trouble free service. State-of-the-art bioreactors and fermentors handle volumes from scale-up 1L, all the way up to 3000 L. Configurations are available with single-use vessels, autoclavable vessels, up to sterilize in place (SIP) systems.
    [Show full text]
  • Kimblecatalog Dwkcover Digital.Pdf
    1 ADAPTERS 223 GAS SAMPLING 16 AMPULES 226 HYDROMETERS 16 ARSINE GENERATORS 229 ISO 17 BEADS 235 JARS 18 BEAKERS 236 JUGS 21 BOTTLES 237 KITS AND LABSETS 41 BURETS 265 NMR 47 CAPS, CLOSURES, SEPTA 271 PETROCHEMICAL 59 CELL CULTURE 289 PIPETS 62 CENTRIFUGE TUBES 294 PURGE AND TRAP 71 CHROMATOGRAPHY 295 RAY-SORB 112 CLAMPS 300 ROTARY EVAPORATORS 114 CONCENTRATORS 305 SAFETY 118 CONDENSERS 319 SERIALIZED AND CERTIFIED 124 CONES 324 SLEEVES 124 CRUCIBLES 324 STARTER PACKS 125 CYLINDERS 325 STIRRERS 131 DAIRYWARE 328 STOPCOCKS AND VALVES 135 DESICCATORS 337 STOPPERS 135 DISHES 340 TISSUE GRINDERS 136 DISPENSERS 348 TUBES 136 DISSOLUTION VESSELS 365 VACUUM AND AIRLESS 137 DISTILLATION 374 VIALS 158 DRYING 389 WASHERS 159 EXTRACTION 390 WEIGHING BOATS 165 FILTRATION 391 TECHNICAL INFORMATION 179 FLASKS 433 INDEX TABLE OF CONTENTS TABLE 210 FREEZE DRYING 210 FRITTED WARE 211 FUNNELS Kimble has the products and expertise to support our customers’ workflows. We focus on providing laboratory glassware solutions from sample storage to sample disposition for market segments such as petrochemical, pharma/biotech/life sciences, environmental and food/beverage. With our breadth of products and depth of knowledge, Kimble offers everything you need to streamline your workflow and simplify everyday life in the lab. From vials and NMR tubes to barcoding services and beakers, we’ve got you—and your sample— covered from start to finish. Discover why Every Sample Deserves Kimble Sample Collection Sample Storage Sample Preparation Detection Sample Disposition
    [Show full text]
  • 130-77 Instruction Manual Updated 10/20/2020 Ver
    OFITE HTHP Viscometer Part No. 130-77 Instruction Manual Updated 10/20/2020 Ver. 9 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. · Houston, Texas · 77065 · U.S.A. Tele: 832.320.7300 · Fax: 713.880.9886 · www.ofite.com ©Copyright OFITE 2015 Intro ..................................................................................................2 Table of Components ....................................................................................3 Contents Specifications .................................................................................5 Setup ................................................................................................6 Computer ....................................................................................6 Viscometer ..................................................................................7 Control Panel ..................................................................................8 Operation .........................................................................................9 Software Start ...............................................................................14 Calibration .....................................................................................18 Fluid Manager ...........................................................................22 Software ........................................................................................23 Options ......................................................................................23 Save Rate Settings
    [Show full text]