Differentiation and Identification of Fentanyl Analogues Using GC-IRD
Total Page:16
File Type:pdf, Size:1020Kb
Forensic Chemistry 20 (2020) 100255 Contents lists available at ScienceDirect Forensic Chemistry journal homepage: www.elsevier.com/locate/forc Diferentiation and identifcation of fentanyl analogues using GC-IRD T ⁎ ⁎ Agnes D. Winokura, , Lindsay M. Kaufmana, Jose R. Almirallb, a DEA Southeast Laboratory, Miami, FL, USA b Department of Chemistry and Biochemistry and Center for Advanced Research in Forensic Science (CARFS), Florida International University, Miami, FL, USA HIGHLIGHTS • Demonstration of the diferentiation and identifcation of fentanyls using GC-IRD. • Optimization of GC-IRD parameters including chromatographic and spectral acquisition. • Reporting of limitations in sensitivity for casework samples. • Case study description involving the use of GC-IRD for analysis of a polydrug mixture. ARTICLE INFO ABSTRACT Keywords: Fentanyl analogues and their positional isomers have similar chemical structural confgurations making them GC-IRD difcult to identify and diferentiate. Gas chromatography coupled to a gas-phase infrared detector (GC-IRD) is a Fentanyl analogues useful and powerful tool for the unambiguous identifcation of fentanyl compounds where traditional analytical PTV techniques such as gas chromatography–mass spectrometry (GC–MS) ofer limited information for this class of Light pipe compounds. In this study, we demonstrate the utility of GC-IRD and show how this complementary information Positional isomers enables the identifcation of fentanyl analogues (2- and 3- furanylfentanyl, 2-furanylbenzylfentanyl, croto- nylfentanyl, cyclopropylfentanyl, methoxyacetylfentanyl, carfentanil, meta-fuoroisobutyryl fentanyl, para- fuoroisobutyryl fentanyl and ortho-fuoroisobutyryl fentanyl) when combined with GC–MS data. A description of the operating conditions including how the optimization of GC-IRD parameters can enhance the spectral resolution and unambiguous identifcation of these fentanyl analogues is presented, for the frst time. In par- ticular, the efects of light pipe temperatures, acquisition resolution, the use of a programmed temperature vaporizing (PTV) inlet, and the analytical concentration of the sample were evaluated. A real-world case ex- ample illustrates the current challenges frequently encountered in casework and how the implementation of GC- IRD may overcome some of these challenges in fentanyl diferentiation and identifcation. 1. Introduction networks. While there have been recent advancements to address analytical capability gaps, such as novel search algorithms [4] and the The United States declared a national public health emergency in enhancement of communication and information sharing, such as the October of 2017 in response to the Opioids Crisis [1]. Since 2014 there Drug Enforcement Administration (DEA)’s Synth-Opioids Real Time has been a signifcant increase of drug related deaths attributed to the Communication Network [5], there are still opportunities for the im- abuse of opioids, with over 60,000 deaths in 2017 [2]. Fentanyl and provement of technology and methodology geared to overcoming ex- related substances are among the opioids having the most impact on isting analytical challenges in seized drug evidence samples. The che- drug overdose deaths [2]. Following the trend of fentanyl-related mical structure of fentanyl is manipulated in clandestine laboratories overdoses, there has been a dramatic increase of fentanyl and fentanyl creating new variations of the substance that have resulted in a long list isomer seizures submitted and analyzed in crime laboratories from 978 of new analogues, whose structural similarity makes it difcult to de- in 2013 to over 30,000 fentanyl identifcations alone in 2018 [3]. Rapid tect and identify using laboratory traditional analytical schemes [4]. detection, identifcation, and reporting of these novel fentanyl sub- Forensic scientists routinely utilize electron impact gas chromato- stances is vital to the assessment and understanding of the illicit drug graphy-mass spectrometry (EI-GC–MS) for the separation and identif- markets in specifc locations and to the disruption of distribution cation of substances in drug samples; however, the use of GC–MS for the ⁎ Corresponding authors. E-mail addresses: [email protected] (A.D. Winokur), [email protected] (J.R. Almirall). https://doi.org/10.1016/j.forc.2020.100255 Received 30 March 2020; Received in revised form 24 May 2020; Accepted 29 May 2020 Available online 05 June 2020 2468-1709/ © 2020 Elsevier B.V. All rights reserved. A.D. Winokur, et al. Forensic Chemistry 20 (2020) 100255 Fig. 1. Chemical structures of the fentanyl substances analyzed in this study. analysis of fentanyl samples comes with analytical challenges and a study comparing analysis by GC–MS and LC-Ion Trap MS for a number limitations. These analytical challenges are often due to the nature of of positive cases identifed for synthetic opioids in toxicological sam- samples being submitted to forensic science providers for analysis. ples, Shof et al. demonstrated that while only 9 cases of furanyl fen- Isomeric interferences, low purity, and insufcient amount of samples tanyl were detected by GC–MS, 37 cases were detected by LC-Ion Trap are among those challenges. Fentanyl and fentanyl-related substances MS [13]. More concerning, their study showed only 30 cases of car- are of high toxicity and present a signifcant hazard to those ingesting fentanil detected by GC–MS, compared to 134 cases detected via LC-Ion the substance. Thus, most often fentanyl and fentanyl-related sub- Trap MS [13]. Recently, Mallette et al. described the characterization stances are mixed with other substances resulting in the fentanyl-re- and diferentiation of cyclopropylfentanyl, crotonylfentanyl, and 3- lated analytes being present in illicit samples at very low concentra- butenylfentanyl in drug samples using a combination of techniques to tions. It is not uncommon to fnd a sample with numerous fentanyl include NMR, Fourier transform infrared spectroscopy (FTIR), and analogues present or composed of a mixture of substances with very GC–MS [14]. Other techniques such as thermal desorption direct ana- similar chemical structures. In the Maher et al. study on the difer- lysis in real time (DART) and ion mobility spectrometry (IMS) have also entiation of regioisomeric forms of trifuoromethylphenylpiperazines, been shown to provide useful characterization of fentanyl analogues these researchers describe the challenge of diferentiating between [15]. In a study by Lurie et al., incomplete chromatographic resolution identical mass spectra for the three regiosomeric 2-, 3-, and 4-tri- between fentanyl-related compounds were subsequently identifed fuoromethylphenylpiperazines [6]. There have been numerous pub- using retention times and dual multiple-reaction monitoring [16]. lished studies using GC-IRD for the analysis of controlled substances Other studies include the direct-infusion techniques with electrospray- with isomeric challenges, such as piperazines, phenethylamines, and mass spectrometry (ESI-MS), LC-atmospheric pressure ionization- designer drugs [6–12]. For example, the Clark et al study on the ring tandem mass spectrometry, coiled microextraction and portable and side chain regioisomers of ethoxyphenethylamines demonstrates GC–MS, ionic liquid-modifed disposable electrochemical sensor strips, the advantages of GC-IRD analysis for the identifcation of MDEA, and ion mobility spectrometry [17–23]. MDMMA, and MBDB [7]. This paper ofers an alternative and complementary technique to To overcome limitations associated with GC–MS, scientists have the widely used EI-GC–MS method in order to enhance the capability of turned to other complementary methods for the analysis of fentanyl laboratories when analyzing fentanyl-related substances that prove to analogues, such as liquid chromatography- ion trap mass spectrometry be difcult to identify using conventional analytical techniques, such as (LC-Ion Trap MS), nuclear magnetic resonance spectroscopy (NMR). In GC–MS. Following the guidelines developed by the Scientifc Working 2 A.D. Winokur, et al. Forensic Chemistry 20 (2020) 100255 Fig. 2. Mass spectra diferences for 2- and 3-furanylfentanyl. Group for the Analysis of Seized Drugs (SWGDRUG) [24], GC-IRD (a injected into a GC where analytes are separated as they fow through hyphenated category B and A technique) can be utilized to diferentiate the GC column. Once separated, analytes enter the IRD through a between fentanyl analogues with the same molecular weight and very 120 mm long capillary with a 1 mm internal diameter. This capillary, similar chemical structures. designated the light pipe, is enclosed in a heating block at the desired To the authors' knowledge, this is the frst reporting of a compre- temperatures to keep samples in the vapor state while interacting with hensive optimization study for the analysis of fentanyl analogues by the IR beam and characteristic absorption spectra are detected [28,29]. GC-IRD in peer-reviewed literature. There have been brief reports on One of the limitations of the GC-IRD is its somewhat lower sensi- the GC-IRD analysis of fentanyl-related compounds, for example the tivity, in comparison to GC–MS. Mass loadings of of less than 25 ng on- comparison of GC-IRD analysis to Q-TOF LC-MS for the detection and column (equivalent to a 1 μL injection of a 25 ppm sample) generally identifcation of 2- and 3-furanylfentanyl isomers [25]. Other studies of produce undefned spectra, making the instrument inefective for for- fentanyl-related