Insulation and Your Home: Fact

Total Page:16

File Type:pdf, Size:1020Kb

Insulation and Your Home: Fact Insulation And Your Home: Fact Sheet Health Considerations Environmental & Occupational Health Assessment Program September 2014 You may be thinking about adding new insulation to your existing home if your home is drafty, or you are looking for ways to save money on energy costs. There are many different types of insulation products in the market place, and many different ways to insulate a house. The type of insulation you choose and the way it is installed may affect your health. The goal of this fact sheet is to help you to become an informed buyer. You will learn to examine three things that can impact your health: 1. Chemical ingredients 2. How dampness and temperature extremes affect your insulation choices 3. Why using an experienced installer is so important. This fact sheet focuses on the most commonly used insulation products in existing houses in the Northeast: synthetic polymer foams like spray polyurethane foam (SPF), mineral wool or fiberglass batts, and blown in cellulose. If you are building a new house or addition, there may be additional insulation products for you to consider. Connecticut Department of Public Health 410 Capitol Avenue, Hartford, CT 06066 http://www.ct.gov/dph Insulation and Your Home: Health Considerations September 2014 Page 2 Exposure to some insulation products can cause 1. Ingredients certain health effects if the product is mis- Many building materials including thermal handled, mis-applied, or if the wrong product is insulation contain fire retardants. Certain classes used in certain environments. Common of insulation products may also contain symptoms may include irritated, itchy, watery, or chemical additives such as colorants, blowing burning sensation of the eyes, nose, or throat, or agents, catalysts, and binding agents. Finding itchy skin or skin rashes. Occasionally, some out what is in the insulation may influence your people report breathing difficulties, especially if choices. If you or any household members are they are asthmatic or have other breathing sensitive to any of these chemical ingredients, disorders. Rarely, some people have reported you may choose to look for a different symptoms like nausea, headache, and confusion/ formulation or type of insulation. difficulty concentrating. Sometimes there is an unpleasant odor that does not go away; in some To find out what chemicals are in the insulation of those cases, people have found it difficult to product under consideration, go to the stay in the house. manufacturer’s website and download a copy of How You Can Become Exposed the Material Safety Data Sheet (MSDS). Manufacturers are required to list ingredients There are two main ways that you can become and quantities, as long as they are not exposed to insulation: proprietary ingredients. You can also download a product information sheet (also called a sell Breathing chemical ingredients in the air sheet or cut sheet). Here are some of the This is usually the result of chemical off-gassing. chemical ingredients you might see. A small amount of off-gassing is normal. It should go way within a few days. If it doesn’t, Formaldehyde there may be a problem with the insulation or Can cause eye, nose and mouth irritation the way it was installed. in sensitive people Breathing or skin contact with insulation dusts Can cause respiratory problems There is usually a fair amount of dust generated including acting as an asthma trigger by cutting dried foam or by simply handling Off-gassing is increased in hot, damp loose, fluffy cellulose, or fiberglass, which can environments shed tiny pieces of glass that can be itchy. The Found in some fiberglass insulation insulation contractor should clean thoroughly products after they are finished. This includes using a Main component in Urea Formaldehyde vacuum with a HEPA filter to pick up the dust. Foam Insulation (UFFI)- improper This should be done before the household installation in 1970’s caused members come back home. formaldehyde Connecticut Department of Public Health Environmental & Occupational Health Assessment Program 860-509-7740 http://www.ct.gov/dph/ieq Insulation and Your Home: Health Considerations September 2014 Page 3 off-gassing and respiratory complaints, may be more expensive than the borate- leading to a widespread UFFI ban in the ammonium sulfate mix, but may release US and Canada. fewer odors. Fire Retardants Catalysts Protecting your home from fire is important. Catalysts are added to the mix of Codes require fire retardants in most types of ingredients in foam insulation products to thermal insulation. enable the chemical reaction to occur to Foam Insulation Products: make the foam. Some catalysts are made with a class of chemicals called amines. Certain fire retarding chemicals are These can off-gas and produce a fishy or routinely added to flexible and rigid foams. sickenly sweet odor if the foam does not Some of these chemicals do not bind to the harden or cure properly, and this off- finished insulation material. They are gassing can continue for many weeks. The continuously released into the environment resultant odor has made some people ill. throughout the life cycle of insulation. Some have been implicated in disrupting normal thyroid hormone function, nervous 2. Environmental Conditions system development, and are potentially Your choices for types of insulation should carcinogenic. be guided by which area of the house you plan on insulating. Cellulose Insulation: Attics: Ammonium sulfate and boric acid are fire retardants commonly found in cellulose If you plan on adding insulation to your insulation. Occassionally, the ammonium home, you can realize the biggest energy sulfate can off-gas and produce an odor. In savings by insulating your attic. Common damp environments, it can also form attic insulation choices include loose fill corrosive byproducts that can degrade cellulose, SPF, and mineral wool/fiberglass metal that it comes in contact with. This batts. Attics can present challenges because appears to be more of a concern in hot, of the large variations in temperature in the high humidity environments like the Northeast. That and moisture will narrow southern part of the US. It is possible to types of insulation suitable for attics. A cost purchase an all-borate cellulose product. It effective approach is to first seal floor Cellulose Spray Insulation Polyurethane foam Insulation Connecticut Department of Public Health Environmental & Occupational Health Assessment Program 860-509-7740 http://www.ct.gov/dph/ieq Insulation and Your Home: Health Considerations September 2014 Page 4 penetrations with foam, then cover the floor flow through gable and/or ridge vents and with cellulose or batt type insulation. through soffits by adding baffles in rafter Temperature Extremes: bays. Basements & Crawl Spaces Attics get both very hot and very cold in the Northeast. If you choose spray foam to Many of the same principals apply to insulate the attic, make sure that the specific basements and crawl spaces. Humidity will SPF product used is designed to withstand dictate the type of insulation that will work large temperature swings. Closed cell SPF in the space. Certain types of SPF should is a good choice for Northeast attics not be used in damp basements or crawl because of insulating and vapor retarding spaces, because they will not cure properly. properties. Manufacturers usually make a This can lead to extended periods of off- number of formulations. Check with them gassing (weeks to months) , resulting in to ensure the right one of their products is odors and possible health impacts in some being used for your environment. If not, people. Check with the manufacturer to there could be problems with curing, find out if the specific formulation you are leading to off-gassing, unpleasant odors, interested in is appropriate for your and possible health related effects. basement. Vapor Barriers-Not Always Needed Do not install anything with a vapor barrier If mineral wool/fiberglass batts (like mineral wool/fiberglass bats) without are chosen, they can be consulting with a knowledgeable person purchased with a variety of about the specifics of your space. If backing materials like kraft fiberglass batts or other vapor barriers are paper and reflective foil. These used, make sure the backing material/vapor backings act as a vapor barrier. barrier is facing towards the inside of the house to prevent moisture from Before buying, check with a Exterior wall -Fiberglass knowledgeable source to see batts between studs, accumulating. if a vapor barrier is indicated vapor barrier facing living space. It is ok to use fiberglass in dry basements, for your area, and if so, make but it should not be used in crawlspaces sure that the backing is facing towards the under the house. Fiberglass subjected to living space. Otherwise, you could end up dampness, humidity, or weather can with a mold problem in the attic. become a dirt trap and breeding ground for Ventilation bacteria and mold. Closed cell spray foam or rigid foam would be a better choice for It is important to maintain air flow through crawl spaces where humidity/exposure to the attic space to prevent moisture weather are concerns. accumulation. When installing any type of insulation in the attic, allow for natural air Connecticut Department of Public Health Environmental & Occupational Health Assessment Program 860-509-7740 http://www.ct.gov/dph/ieq Insulation and Your Home: Health Considerations September 2014 Page 5 Side Wall Insulation It is advisable to choose an installer who has been in business for a long time. If you do The most common choices for a retrofit job have any problems, you want to be able to have are injection foam or blown in cellulose. them come back and work with you to resolve The installer will drill a series of horizontal the problem. See page 6 for some common holes from either the inside or outside.
Recommended publications
  • Water Vapor Migration and Condensation Control in Buildings 2
    HPAC Info-dex 2 Engineering Basics he articles in this section were selected by HPAC’s Engineering Editor based on their generic and fundamental nature. Engineering Basics T is intended to be used by engineers, contractors, and facility managers 2 to brush up on engineering fundamentals across a wide range of subjects pertaining to mechanical systems design, building science, and product selection. This year’s selections are as follows: 72 “Water Vapor Migration and Condensation Control in Buildings”—The basics of psychrometric analysis of moisture conditions, including evaluation of vapor barriers and other construction features, and internal and external moisture sources. Examples help guide the discussion of this complex topic. William G. Acker 89 “BACnet: Answers to Frequently Asked Questions”—Answers to frequently asked questions about BACnetE provide invaluable information for building automation system designers, owners, and operators. A primer on the revolutionary development in the building automation and controls industry. By H. Michael Newman Circle 350 on Reader Service Card June 1998 HPAC Heating/Piping/AirConditioning 71 MOISTURE CONTROL Water Vapor Migration and 2 Condensation Control in Buildings The basics of water vapor analysis and control By WILLIAM G. ACKER, pressure). Thus the water vapor lustrated in Equations 4 and 5. President, diffusion is from inside to outside. The inside and outside vapor Acker & Associates, In warmer climates with short pressures can be determined from Green Bay, Wis. heating seasons, the water vapor test data or by using typical psy- drive is from outside to inside due chrometric data for that region. If ater vapor is the gaseous to the drying effect of indoor air there is concern over the amount form of water and is an in- conditioning.
    [Show full text]
  • Quick Start Guide
    The Watchdog900 Quick Start Guide Seaira Global • 14021 NC Highway 50 • Surf City, NC 28445 www.seairaglobal.com WatchDog 900 Quick Start Guide • Prepare Crawl Space for Installation • Tips for Dehumidifier Installation • Operating Instructions • Benefits of a Dehumidifier • Common Terms • Parts Diagram • Trouble Shooting • Submit Warranty • Additional Resources While you’re waiting for your new dehumidifier to arrive, here are a few topics to keep in mind. How to Prepare Your Crawl Space for Installation If you decide to install your dehumidifier in a crawl space, there are a few steps you need to take prior to installation. 1. First, you will need clean out any debris that may be cluttering up the crawl space. This will make sure that there are no hidden problems such as cracks in the foundation. It will also ensure that the vapor barrier can be installed properly. In addition, cleaning out any unnecessary items will make it much easier to move around in the crawl space. Being able to move around more easily is useful for a hassle free installation, as well as for future maintenance that may need to be done. 2. After the crawl space is clear, you will need to inspect it for any potential issues so they can be fixed prior to installation. For instance, you may notice signs of pests or rodents in the crawl space. The crawl space could also show signs of structural issues, such as damaged floor joists or girders. Most importantly, you need to ensure that all signs of excess moisture are taken care of.
    [Show full text]
  • Oregon Residential Energy Code Rev
    Oregon Residential Energy Code Rev. March 2005 • No. 15 Moisture Control Measures This pamphlet is one in a series that describes residential sheets may serve as vapor retarders for unfaced insul- energy conservation requirements of the Oregon ation. Certain paints are formulated to act as vapor Residential Specialty Code and the Structural Specialty retarders. Check with your building official to be sure Code for Group R buildings three stories and less in paints are locally accepted. height. Other pamphlets in this series may be obtained from Oregon Dept of Energy at www.oregon.gov/energy/ Figure 1 shows the diffusion process and how vapor or local building departments or from Oregon Building retarders work. Codes Division. Wall vapor retarders Moisture control measures required by the Oregon Residential Energy Code include vapor retarders in walls, Energy code requires a one-perm vapor retarder in floors, and ceilings without attics and a ground cover in walls. Faced insulation may meet both R-value and vapor crawl spaces and below slabs in heated spaces. Section retarder requirements. When unfaced batts or blown-in drawings or written specifications that accompany the batts are used, a vapor retarder must be provided. Vapor plans must show moisture control measures. retarder paints or polyethylene sheets are common wall vapor retarders. Along with damp-proofing and ventilation requirements, moisture control reduces moisture problems Floor vapor retarders in homes and multifamily buildings. A one-perm formulated vapor retarder is also required on floors. The vapor retarder requirement is often met by Vapor retarder requirements using exterior grade plywood or strand board sheathing Vapor retarders reduce moisture condensation within for the floor.
    [Show full text]
  • RREAL's Installation Manual for Solar Thermal Panels (Also Known As “Solar Powered Furnace/SPF”)
    SPF Installation Manual Rural Renewable Energy Alliance (RREAL) MADE 2330 Dancing Wind Road SW, Suite 2 IN Pine River, MN 56474, USA MN [email protected] 218-587-4753 www.rreal.org All Rights Reserved 2010 Version 1.10 Table of Contents Figures Safety Warning............................................ 2 1. Fastening Mounting Rails to Structure.... 5 Important Concerns................................... 2 2. SPF Penetration Areas.................................. 6 3. Silicone Location on Starter Collar........... 7 Parts Definitions........................................ 3 4. Installation of Starter Collar....................... 7 Bill of Materials.......................................... 4 5. Installation of Thermistor........................... 7 Additional Materials................................... 4 6. Hang SPF on Mounting Rails..................... 8 1) Select Location........................................ 5 7. Silicone Location on AI Stint..................... 8 2) Hang Mounting Rails.............................. 5 8. Insulation and Back Draft Dampers......... 9 3) Make Penetrations................................... 6 9. Wiring Diagram............................................ 10 10. Extrusion Cut Location............................ 13 4) Prepare to Hang Panel............................ 7 11. Portrait Mounting Rails............................ 14 5) Hang First Panel....................................... 8 12. Landscape Mounting Rails........................ 15 6) Hang Additional Panels.......................... 8 13.
    [Show full text]
  • Fire Resistant, Self-Adhering Membrane Air & Vapor Barriers
    MANUFACTURER’S GUIDE SPECIFICATIONS SECTION 072713 FIRE RESISTANT, SELF-ADHERING MEMBRANE AIR & VAPOR BARRIERS 900 Hensley Lane • Wylie TX 75098 • 800-527-7092 • www.carlisleccw.com XXXXXX 03.27.15 Carlisle and Sure-Seal are trademarks of Carlisle. ©2015 Carlisle. Rev. 9/9/14 Project: SECTION 07 27 13 FIRE RESISTANT, SELF-ADHERING MEMBRANE AIR & VAPOR BARRIERS PART 1 GENERAL 1.01 SECTION INCLUDES A. A self-adhered membrane and accessory products of fire-resistant composition for use as an air and vapor barrier in exterior walls. B. Materials and installation to bridge and seal the following air leakage pathways and gaps: 1. Connections of the walls to the roof air barrier 2. Connections of the walls to the foundations 3. Seismic and expansion joints 4. Openings and penetrations of window frames, door frames, store front, curtain wall 5. Barrier pre-cast concrete and other envelope systems 6. Door frames Piping, conduit, duct and similar penetrations 7. Masonry ties, screws, bolts and similar penetrations 8. All other air leakage pathways through the walls 1.02 RELATED SECTIONS A. Section 03 30 00 - Cast-In-Place Concrete [NOTE TO SPECIFIER: Require that backup concrete be free of fins, protrusions and large holes] B. Section 04 20 00 - Unit Masonry [NOTE TO SPECIFIER: When concrete masonry unit (CMU) block walls are to receive Air & Vapor Barrier materials it is critical to address surface preparation issues in this section. Due to the method of installation of the CMU, generally from the inside out, the most critical surfaces to receive the Air & Vapor Barrier materials are neglected and not tooled properly.
    [Show full text]
  • Thermal and Moisture Protection: Keeping the Weather out Internet Course
    Rich Text Editor,editor1 http://www.licensetobuild.com/web-class/controls/?mt=coursemanagem... Thermal and Moisture Protection: Keeping the Weather Out Internet Course Learning Objectives Summarize the key elements (either natural or mechanical) of a properly ventilated structure. List and describe at least three specific installation techniques and/or materials that contribute to a properly constructed roof system. Outline at least one design strategy based on "best practices" for the construction of buildings in areas with high humidity. Identify and implement proven methods that will effectively divert moisture from the foundation of a structure. Keeping the Weather Out Protecting buildings from weather and moisture related problems is important for all building professionals. In areas of high humidity, (and ALL Florida counties are considered "warm humid counties" by the Florida Building Code: Energy Conservation 301.2), it is even more important that builders, their employees, and their subcontractors use “Best Practice” procedures to carefully install thermal and weather resistant components. Because of the potential for loss due to consumer complaints and claims, it makes sense for contractors to be trained in moisture control for the homes and buildings they are constructing or renovating. Major performance objectives. One objective of a building envelope system is to provide moisture control. Construction of a building envelope system needs to incorporate methods and materials that prevent or minimize the impact of moisture intrusion. The photo below shows typical damage caused by poorly installed or maintained building envelope components! Too often, exterior shells are simply sealed up without regard for proper installation of house- wraps, flashing and ventilation.
    [Show full text]
  • Installation Manual
    Carbon Heating Film • Easy to install. • Can be used as a sole room heating source (when cover at list 70% of the floor). • Does not circulate pollutants, dust, dirt, allergens or dry air. • May be installed on wall, ceiling, under laminate, engineered wood floors or tile. • Brings soothing warmth to specific rooms or cold areas. • Reduces energy up to 60% compared to forced air heating systems. • Maintenance free, strong and durable. • Complements your home heating system making rooms more comfortable. Read through this entire manual before starting installation. • All electrical connections must be made by a licensed electrician in accordance with national and local codes and standards. • Always join multiple heating film lines in parallel ONLY (never in series). • Always make sure to check the heating film before, during, and after installation of the floor covering. • Each thermostat requires a dedicated circuit at the breaker box. • Must not be installed in damp or wet areas as defined by the National Electrical Code. • Do not fold or wrinkle the heating film, walk on it unnecessarily, or drop heavy or sharp objects on it. • Never overlap the heating film. • Do not install electrical wires or pipes in the floor with the film. • Be sure underlayment contains no cellulose. • Install film only when room temperature is above freezing. • Leave a 6-inch space between film and fireplaces, chimneys, or hot water pipes. • Never use any type of insulation material on top of the heating film. • Do not install the healing mats directly over a foil backed insulation material. • When installing carpet a low tog underlay should be installed followed by a good quality hessian backed carpet.
    [Show full text]
  • Vapor Barrier Interior Primer Sealer 1060-1200
    Vapor Barrier Interior Primer Sealer 1060-1200 Previously ICI Paints PREP & PRIME™ VAPOR BARRIER Interior Water-Based Primer Sealer DESCRIPTION SPECIFICATION A premium quality latex primer sealer and vapor barrier for interior Color: walls and ceilings. It reduces loss of interior moisture through the White (tintable, limit 4 oz/gal) walls to help maintain insulation efficiency and guard against exterior paint adhesion failures caused by condensation. Moisture Clean-up Solvent: and Heat Loss - Every home contains moist air (water vapor) that, in Soap and water the proper proportion, provides a healthy atmosphere. But under winter conditions, when the inside/outside temperatures differ Finish: Flat drastically, the moisture indoors passes through interior walls and condenses within the stud space as it seeks the colder exterior side. Density: The moisture may fill the pockets or voids in insulation, increasing 10.5 lbs/gal (1.26 kg/L) the flow of heat, reducing its insulation value. Insulation must be dry Solids: to function efficiently. Keeping water vapor inside the home will help reduce heat loss and Volume - 34% +/- 1% Weight - 48% +/- 1% guard against moisture damage. Vapor barrier systems can help to provide this protection. Therefore, to help keep moisture inside VOC: apply 1060 Vapor Barrier Interior Primer Sealer to interior walls and 100 g/L (0.84 lbs/gal) maximum ceilings that contact the outside of any unheated areas. To be Refer to MSDS for regulatory VOC effective, a product must have a perm rating of less than 1.0, as set forth by the Federal Housing Administration Minimum Property content of complete product line Standards.
    [Show full text]
  • Floors Above Crawl Spaces: Reducing the Risk of Moisture Accumulation Within Wood Floor Assemblies 3 Building Code
    Floors above Crawl Spaces: Reducing the Risk of TechNote Moisture Accumulation within Wood Floor Assemblies For Residential Buildings in Hot-Humid Climates Floors above vented and open crawl spaces in hot-humid climates are susceptible to moisture CRAWL SPACE FOUNDATION TYPES accumulation that could lead to mold, mildew, and decay within the floor assembly, even Vented (traditional) crawl space: a crawl where crawl spaces are constructed in accordance with building codes. space with a continuous perimeter Water vapor generally migrates from areas of higher temperature and relative humidity to foundation wall (typically masonry) with ventilation openings to the outdoors areas of lower temperature and relative humidity (vapor drive). In a humid climate, during intended to control crawl space humidity. the cooling season, the vapor drive is from the crawl space to the relatively cool and dry indoors through the floor assembly. A vapor impermeable floor covering can trap moisture Open crawl space: a crawl space where in the wood subfloor Conditions within the crawl space can lead to condensation and high individual piers (typically wood, masonry, or concrete) at the building perimeter wood moisture content (see Figure 1 and Figure 2). support beams and floor joists. This TechNote provides design recommendations to reduce the risk of moisture accumulation Unvented (sealed, closed, or within wood floors above crawlspaces in hot-humid climates – IECC climate zones 1A, 2A, conditioned) crawl space: a crawl space and lower portions of 3A below the warm-humid line [1]. The factors that affect moisture with a continuous perimeter foundation accumulation include season, indoor temperature, types of floor insulation and floor covering, wall that is sealed (no wall vents) to and type of crawl space (see sidebar).
    [Show full text]
  • Preventing Moisture Accumulation in Ducts
    INSULATION Glass Fiber Air Transmission Systems: FACTS # Preventing Moisture 52 Accumulation in Ducts In this issue we will address It doesn’t matter what the the sources of water accumu- duct is made of — bare sheet lation in unused ducts located metal, fiber glass lined sheet in unconditioned spaces; the metal, wrapped metal, duct problems associated with board, or flexible duct — the moisture accumulation; and physical laws governing this the means of prevention. phenomenon are the same for all materials. During the heating season, unused air conditioning ducts located in unconditioned spaces How Moisture can become saturated with Accumulates in Ducts water unless certain precautions Ducts without heated air flow- are taken. Low duct tempera- ing through them will cool to tures often result in condensa- temperatures near that of the tion which can accumulate in unconditioned space. substantial amounts of water Insulation, by itself, will not during the winter months. keep unused duct temperatures elevated or stable. Insulation will slow down Sources of Moisture the rate of heat flow through in the Home the duct wall, but unless this The source of accumulated heat is replaced, the tempera- water in unused or non-operat- ture in the duct will fall. When ing ducts is the air within a the temperature falls low home. All air contains some enough, the moisture laden air water in the form of water from within the home will vapor. However, in winter, inside begin to lose its moisture and air typically has more water form condensation. vapor than outside air. When Unless heat is supplied to water vapor laden air cools to a the inside of the duct, conden- low enough temperature, it con- sation will continue to form denses, forming liquid water.
    [Show full text]
  • Vapor and Gas Barriers Critical Building Protection
    PROVIDING A FULL BUILDING ENVELOPE SYSTEM VAPOR AND GAS BARRIERS CRITICAL BUILDING PROTECTION 13895-57277 Meadows-2021.indd 1 5/4/21 2:16 PM VAPOR RETARDANT STANDARDS The importance of a proven vapor and/or gas barrier. Uncontrolled water vapor through concrete slabs has cost building Underslab Vapor Barriers owners, designers and contractors billions of dollars. This moisture The use of underslab vapor barriers is the best method and infiltration into structures contributes to the proliferation of mold, most economical solution for controlling water vapor migration mildew and fungus that can lead to flooring system failures, through concrete slabs. The issue of admixtures and topically including adhesive failures, warping, blistering and staining. In applied materials does not address the issue that concrete cracks addition, water vapor migration carrying alkali can cause structural or the potential for elevated PH levels. failure of the concrete when reinforcing steel is present. ASTM E1993 and ASTM E1745 are the two industry standards Issues Directly Related to Flooring System Failures for vapor barriers and retarders under concrete slabs in contact • Many flooring systems used today form vapor barriers on top with soil. Note that typical polyethylene film does not meet the of concrete slabs and therefore trap water and alkali between requirements of these standards. the flooring system and the slab. Why Use a Gas Barrier? • 1999 federal mandate on VOC emissions created the need and In addition to the concern for moisture protection, other below- use of water-based flooring adhesives. grade contaminants have been identified as being major issues when it comes to occupant health and safety.
    [Show full text]
  • Building Science Digest 014 Air Flow Control in Buildings
    building science.com © 2008 Building Science Press All rights of reproduction in any form reserved. Building Science Digest 014 Air Flow Control in Buildings 2007-10-15 by John Straube Abstract: The control of air flow is important for several reasons: to control moisture damage, reduce energy losses, and to ensure occupant comfort and health. Airflow across the building enclosure is driven by wind pressures, stack effect, and mechanical air handling equipment like fans and furnaces. A continuous, strong, stiff, durable and air impermeable air barrier system is required between the exterior and conditions space to control airflow driven by these forces. Air barrier systems should be clearly shown and labelled on all drawings, with continuity demonstrated at all penetrations, transitions, and intersections. In addition, enclosure assemblies and buildings should be vertically and horizontally compartmentalized, may require secondary planes of airtightness (such as those provided by housewraps and sealed rigid sheathing) and may need appropriately air impermeable insulations or insulated sheathing. Introduction It has long been recognised that the control of air flow is a crucial and intrinsic part of heat and moisture control in modern building enclosures [Wilson 1963, Garden 1965]. That this statement is true for all climates has been a more recently developed awareness [Lstiburek 1994]. A large fraction of a modern, well-insulated building's space conditioning energy load is due to uncontrolled air leakage. Wintertime condensation of water vapor in exfiltrating air (or summertime condensation of infiltrating air) within assemblies is one of the two major sources of moisture in the above-grade enclosure (driving rain being the other).
    [Show full text]