Welcome to Titon Ventilation Systems. We are experts in the design, manufacture, specification and supply of residential ventilation systems. Our extensive range and comprehensive support will provide you with a solution for any housing project.

About Titon 4 Ventilation Systems 5 Sales & Service 6 Quality & Testing 7

Controls, and Sensors Heat Recovery aura-tTM ...... 58 HRV1.35 Q Plus...... 8 auramode® ...... 59 HRV1.35 Q Plus - Enthalpy ...... 10 aurastat® V & VT...... 60 HRV1.6 Q Plus...... 12 auralite® ...... 61 HRV1.75 Q Plus...... 14 Switches...... 62 HRV2 Q Plus...... 16 Sensors...... 63 HRV2 Q Plus - Enthalpy ...... 18 HRV2.85 Q Plus...... 20 Extract Ventilation HRV3 Q Plus...... 22 Vent-Trex...... 64 HRV3 Q Plus - Enthalpy ...... 24 Mixed Flow Inline Fan...... 66 HRV3 PH ECOaura - Passivhaus...... 26 Intermittent Fans - Axial...... 68 HRV10 Q Plus...... 28 Intermittent Fans - Centrifugal...... 70 HRV10.25 Q Plus...... 30 HRV10.25 Q Plus - Enthalpy ...... 32 Trickle Vents HRV20 Q Plus...... 34 Window Ventilators...... 72 H200 Q Plus...... 36 Slot Ventilators...... 72 SR700 - Single Room Heat Recovery Unit ...... 38 Sound Attenuators - Semi Flexible...... 74

Heat Recovery Accessories Trimbox NO2 Filter® ...... 40 Trimbox Filter® ...... 42 HRV Condensate Drain Cover...... 44 HRV Duct Cover...... 45 HRV First Fix Solutions...... 46 HRV AV Mounting Kits...... 47 Duct Heater...... 48

Continous Mechanical Ventilation CME3 Q Plus...... 50 CME Access Panel - Non Fire Rated...... 52 CME Access Panel - Fire Rated...... 53 Solitude...... 54 Solace...... 56

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 3 About Titon

Titon is a long established company specialising in ventilation, it was founded in 1972 and is based in the UK. It floated on the London Stock Exchange in 1988 as Titon Holdings Plc and employs around 230 people between its UK operations and interests in Europe, USA and South Korea.

Titon manufactures and supplies a range of products including sophisticated energy conserving whole-house mechanical ventilation units, natural ventilation products and fittings for window and doors. The product ranges also include high performance and specialist solutions to deal with today’s most demanding builds where noise/air pollution and indoor air quality are our prime concerns.

Sales and Marketing Office - Colchester

Manufacturing Site - Haverhill

4 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Ventilation Systems UK Manufacturer

Titon’s Ventilation Systems Division is dedicated to the design, manufacture, supply and specification of ventilation systems primarily for domestic use.

Due to continual improvement within its Ventilation Systems Division Titon offers a competitive range of mechanical ventilation products. Our innovative yet extremely efficient compact MVHR (Mechanical Ventilation with Heat Recovery) units offer whole-house ventilation to protect the home from harmful contaminants but also help ventilate to an acceptable level. To complement our range, Titon also offers our unique CME (or MEV, continuously running central extract) that is ideal for continuous extract of stale, damp and polluted air to the outside environment.

Titon Ventilation Systems have continued to expand its product portfolio and

® recently added its award winning Trimbox NO2 Filter which removes NO2 to safe levels within the home, coupled with our first fix solution to allow easy installation and our ducting flexible sound attenuators that offer extra sound reduction. Titon has proved to be a winner with concept, design and development of its ventilation range.

Titon Ventilation Systems can design bespoke systems on CAD using Revit to complete calculations to ensure air supply complies with current Building Regulations. Titon supports the NICEIC to ensure that our units are fitted to correct standards to allow for our MVHR/CME units to operate at their very best. the design and documentation of building projects. Titon offers complete Revit models for all of its MVHR range as a simple single family model. Service zones have been included to ensure co-ordination with other elements and will provide manufacturers’ details, performance criteria and maintenance information.

For more information visit www.titon.co.uk/bim.

* HRV graphic may differ from illustration shown when actually purchased.

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 5

332 118

Double Double Airbrick Airbrick

RWP MJ

220x90mm Th 220x90mm Th 220x90mm

204x60mm

204x60mm

204x60mm 204x60mm 204x60mm 220x90mm Th 220x90mm Th 220x90mm Th 204x60mm 220x90mm Th L 220x90mm Th Clearance Zone 220x90mm Th NHBC 204x60mm

204x60mm

FW FW FW 220x90mm Th

220x90mm Th

204x60mm 204x60mm 204x60mm 204x60mm FW 220x90mm Th 204x60mm 204x60mm 204x60mm

204x60mm 220x90mm Th

FW FW FW 220x90mm Th 204x60mm 220x90mm Th 204x60mm 220x90mm

220x90mm Th (HMB) HRV1.75 FW 220x90mm Th

M 220x90mm

FW FW 204x60mm

1 2 3 4 5 6 7 8 9 10

11 . 12

20 19 18 17 16 15 14 13 3x3 . letterboxes

MJ In addition some of the more popular products can be purchased online via TitonDirect, where the latest offers and products can be found, www. titondirect.co.uk www.titon.co.uk Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Sales and Technical EMS 513709 FM26687 6

these newsletters is easy via the Titon website, these newsletters is easy via the Titon subscribers on new products, information and services. Subscription to subscribers on new products, information is reinforced by the publication of regular email newsletters to update is reinforced by the publication of regular CPD Presentations.Titon’s position as experts on domestic ventilation to disseminate this information in the structured and unbiased form of structured and unbiased form of to disseminate this information in the Titon prides itself on Regulatory and Standards knowledge, and can visit Standards knowledge, and can visit Titon prides itself on Regulatory and with a more empathetic approach to market demands. with a more empathetic approach to s team focus, benefiting the sales team design, development and manufacturing is therefore very important to the company to retain its existing research, to retain its existing research, is therefore very important to the company tise. It of service and expertise. It definition cannot provide the same standard traditional route to market is through wholesalers or distributors, who by wholesalers or distributors, who by traditional route to market is through and called off when required. This is unique in an industry where the unique in an industry where the and called off when required. This is dvance plots on a development in advance Orders can be scheduled for specific settings. with calculated ventilation capabilities based on duct run lengths and unit based on duct run lengths and unit with calculated ventilation capabilities CAD/Revit drawings of dwellings and provide detailed ventilation designs provide detailed ventilation designs CAD/Revit drawings of dwellings and ceive The Design Office can receive product knowledge to aid our customers. Systems Division offering peace of mind to callers and have extensive have extensive peace of mind to callers and Systems Division offering Dedicated Sales and Technical Departments support the Ventilation Ventilation Technical Departments support the Dedicated Sales and application problems and offer ‘hands-on’ advice. application problems t in to assist in teams have a technical background specifiers. The sales ers and customers and to give fast and efficient support to locations, in order The company employs specialists for each market sector in regional in regional specialists for each market sector The company employs throughout the UK and overseas. throughout Titon has a strong sales and specification presence presence sales and specification Titon has a strong

Service Sales & & Sales 7 All our MVHR are tested for air leakage Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Sales and Technical

All our MVHR are electronically tested To enable Titon to demonstrate its quality, it will test it will test To enable Titon to demonstrate its quality, latest British and products, wherever applicable, to the approval. European standards – including full CE Perhaps uniquely in the Ventilation Systems sector, all Titon whole-house units are tested on the production line to to sector, all Titon whole-house units are tested on the production line Perhaps uniquely in the Ventilation Systems third party levels which match those achieved when each model was officially ensure performance and air tightness for sold in the UK and those models subject to sometimes more rigorous testing tested. This is true both of units being export into mainland Europe. Titon has a large research, development and testing department in Haverhill, Suffolk. All of Titon’s products are and testing department in Haverhill, Suffolk. All of Titon’s products are Titon has a large research, development as well as testing to ensure they meet the performance criteria specified, subjected to a rigorous regime of quality delivering reliability and optimum performance. Titon’s objective of consistent high quality performance is met by mandatory adherence to procedures, and Titon and Titon is met by mandatory adherence to procedures, consistent high quality performance Titon’s objective of core quality management are met and monitored in eight This ensures standards has full ISO 9001 Certification. a systematic approach of people, a process approach, focus, leadership, the involvement areas, including customer supplier a factual approach to decision making and mutually beneficial to management, continual improvement, the ISO 14001 Environmental Management Standard Certification. relationships. In addition, Titon also holds When it comes to quality, Titon is committed to excellence and the total satisfaction of its customers the total satisfaction of its customers is committed to excellence and Titon quality, When it comes to its customers a offer supplier and to It strives to be an efficient requirements. and their specific and handle and deliver products service. The company seeks to courteous and effective prompt, Health and Safety of its staff, or to the the environment that is not detrimental to services in a manner outside its facilities. general public both inside and customers, or the Testing Quality & Quality

332 118

Double Double Airbrick Airbrick

RWP MJ

220x90mm Th 220x90mm 220x90mm Th 220x90mm

204x60mm

204x60mm

204x60mm 204x60mm 204x60mm 220x90mm Th 220x90mm Th 220x90mm Th 204x60mm 220x90mm Th L 220x90mm Th Clearance Zone 220x90mm Th NHBC 204x60mm

204x60mm

FW FW FW 220x90mm Th

220x90mm Th

204x60mm 204x60mm 204x60mm 204x60mm FW 220x90mm Th 204x60mm 204x60mm 204x60mm

204x60mm 220x90mm Th

FW FW FW 220x90mm Th 204x60mm 220x90mm Th 204x60mm 220x90mm

220x90mm Th (HMB) HRV1.75 FW 220x90mm Th

M 220x90mm

FW FW 204x60mm

1 2 3 4 5 6 7 8 9 10 11 12

20 19 18 17 16 15 14 13 3x3 letterboxes

MJ Features & Benefits ÆÆ Highly versatile compact unit ÆÆ Extremely low Specific Fan Power; down to 0.65 W/l/s ÆÆ Highly efficient heat exchanger; up to 88% ÆÆ Airflow up to 66 l/s (239m3/h) at 100 Pa ÆÆ Accepts 125mm diameter ducting, no adaptors required ÆÆ Intelligent frost protection, stepped reduction of supply air rates prevents HRV unit from freezing ÆÆ ISO Coarse 55% (G3) filters as standard with For use in small to ISO Coarse 60% (G4) as an option medium sized dwellings ÆÆ Enthaply Heat Cell option available ÆÆ Fully adjustable boost overrun timer 0-60

HRV1.35 Q Plus HRV1.35 The enhanced capacity ultra compact HRV1.35 Q Plus minutes; can be used with non-latching continuously running whole-house ventilation unit with (momentary) switches to prevent unit from heat recovery is independently tested by the BRE and being accidentally left in boost mode maintains an ultra compact size despite its improved ÆÆ Setback facility to reduce ventilation where airflow performance. local regulations allow Combining extremely low power consumption and a ÆÆ Intelligent Summer Bypass and humidity highly efficient heat exchanger, this unit enhances SAP controls performance via Appendix Q, and yet remains versatile enough in size to be equally as functional in larger ÆÆ Volt free switching control apartments as it is in small to medium sized dwellings. ÆÆ Intelligent controller, quick and easy to commission The Eco versions offer a 100% airflow diverting Summer Bypass, recognised and listed in the UK Product ÆÆ Lightweight for easy handling Characteristics Database. They also include intelligent ÆÆ Re-usable plastic filter frames humidity options and can be fitted with the auralite® status ÆÆ Quick fix mounting bracket indicator (HMB and B models) or the auramode®, aurastat® or aura-tTM controllers (B models only). ÆÆ On board aura-tTM capabilities ÆÆ Patented ÆÆ Independent fan adjustment ÆÆ SUMMERboost® facility ÆÆ Effective in reducing pollutants in the home and improving Indoor Air Quality (IAQ), therefore reducing the risk of Toxic Home

Ultra energy efficient Heat Recovery Ventilation unit Recovery efficient Heat Ultra energy Syndrome

Eco Versions: ÆÆ Compatible with auralite® status indicator ÆÆ Removable airtight filter covers for easy filter maintenance ÆÆ Compatible with Eco-aura range; aurastat® auramode® and aura-tTM controllers and auralite® (TP519) status indicator. ÆÆ Duct heater control (requires independent power supply) ÆÆ Available in left and right handed configurations Æ auralite® Æ BMS compatible via RS485 auramode® aura-tTM aurastat®

8 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Product Codes Drawing & Dimensions HRV1.35 Q Plus B Eco-aura controls ready - TP418B/LH (left hand config) or TP418B/RH (right hand config) - Energy Rating A 600 TP418BC - Energy Rating A. 600 Filters: XP40032/099 - ISO Coarse 55% (G3) filters fitted as standard (UK only). 300 XP46022/099 - ISO Coarse 60% (G4) filters fitted on request. (Europe fitted as standard).

Standards 430 Conforms to requirements of UK statutory Building Regulations and Technical Standards for Ventilation and BRE 398. 100 285 Uninstalled SAP Appendix Q tested 295 Installed (https://www.ncm-pcdb.org.uk/sap/pcdbsearch. jsp?pid=34) Exceeds requirements of Building Regulations Approved Document L (England & Wales). Performance The figures and compliance levels below relate to current SAP requirements. EU RoHS Directive compliant. Revised SAP guidance will have an effect on performance and up-to-date Conforms to requirements of EC council directives figures can be found on the relevant product page at www.titon.co.uk. relating to Electromagnetic Compatibility and Electrical Safety: Exhaust terminal Fan speed Specific fan Heat 2006/95/EC (LVD), 2004/108/EC (EMC) configuration* setting power exchange efficiency EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/ (W/l/s) (%) A1:2004. Kitchen + 1 100% 0.65 88 additional wet room variable CE Marked. Kitchen + 2 100% 0.69 87 Specification additional wet rooms variable Kitchen + 3 100% Dimensions: 600mm wide x 430mm high 0.84 85 (excluding ports) x 285mm deep (295mm with additional wet rooms variable Kitchen + 4 100% mounting bracket) 1.04 84 additional wet rooms variable Weight: 16kg Kitchen + 5 100% 1.25 84 Finish: White Paint additional wet rooms variable Kitchen + 6 100% 1.53 84 Materials: additional wet rooms variable Housing: Zintec sheet steel housing, powder coated white Figures taken from the BRE Test Results. Internals: Expanded polypropylene (EPP) *Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance Heat exchanger: Polystyrene requirements. Internal insulation: Closed cell foamed Nitrile rubber, class ‘O’ fire rating Standard filters: Grade ISO Coarse 55% (G3) synthetic filters Nominal fan performance Guarantee period: 3 years (UK only) Electrical: 230V ~ 50/60Hz, 3A fuse 1 27 14 Installation: Install in accordance with 2 49 32 regulatory requirements, such as the Domestic 3 55 41 Ventilation Compliance Guide (England & Wales) 4 64 58 and the Residential Ventilation Association 5 72 78 6 81 103 recommendations. 7 96 154 Maintenance: Service and filter clean/replacement 8 100 168 subject to local environment - see product manual. Acoustics: Full acoustic data available online www.titon.co.uk/acoustics

*@FID (0 Pa) All units offer 100% variable speed control. Performance curves for Eco version. Acoustic Data

dB(A) @ 3m Hemispherical dB(A) @ 3m Spherical Product % of Airflow Max flow Casing Induct Inlet Induct Outlet Breakout Casing Breakout 37% 22l/s @ 12Pa 28 39 19 16

HRV1.35 Q Plus Eco 65% 39l/s @ 38Pa 40 52 29 26

100% 60l/s @ 100Pa 47 61 36 33

For full frequency acoustic data at various speeds please see www.titon.co.uk. All acoustic data is third party tested at Sound Research Laboratories (SRL) Ltd.

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 9 Features & Benefits

ÆÆ Highly versatile compact unit ÆÆ Highly efficient enthalpy counter flow heat exchanger ÆÆ Accepts 100mm or 125mm diameter ducting, no adaptors required ÆÆ Intelligent frost protection ÆÆ ISO Coarse 55% (G3) filters as standard, ISO

- Enthalpy Coarse 60% (G4) as an option ÆÆ Fully adjustable boost overrun timer 0-60 minutes; can be used with non-latching (momentary) switches to prevent unit from For use in small to being accidentally left in boost mode medium sized dwellings ÆÆ Setback facility to reduce ventilation where local regulations allow The high capacity HRV1.35 Q Plus continuously running whole-house ventilation unit with heat recovery ÆÆ Intelligent Summer Bypass and humidity

Q Plus maintains an ultra compact size despite its improved controls airflow performance. ÆÆ Volt free switching control Combining extremely low power consumption and a highly Æ efficient heat exchanger, this unit remains versatile enough in Æ Intelligent controller, quick and easy to size to be equally as functional in larger apartments as it is in commission small to medium sized dwellings. ÆÆ Lightweight for easy handling Æ The counter flow enthalpy heat exchanger has a selective Æ Re-usable plastic filter frames polymer membrane film to achieve low air leakage levels ÆÆ Quick fix mounting bracket while providing moisture recovery from the exhaust air. These models are ideal for living areas with low humidity, ÆÆ On board aura-tTM capabilities avoiding frost build up at low temperatures, they also have an ÆÆ Patented antimicrobial membrane and long life cycle. Æ Independent fan adjustment

HRV1.35 HRV1.35 Æ The HRV1.35 Q Plus comes in Eco versions only with a ÆÆ SUMMERboost® facility 100% airflow diverting Summer Bypass. It also includes intelligent humidity options and can be fitted with auralite® ÆÆ Effective in reducing pollutants in the home status indicator or the auramode® and aurastat® controllers. and improving Indoor Air Quality (IAQ), therefore reducing the risk of Toxic Home Syndrome

Eco BE Models: ÆÆ Compatible with Eco-aura range; aurastat® auramode® and aura-tTM controllers and auralite® (TP519) status indicator. ÆÆ Duct heater control (requires independent power supply) ÆÆ Available in left and right handed

Ultra energy efficient Heat Recovery Ventilation unit efficient Heat RecoveryUltra energy configurations ÆÆ BMS compatible via RS485

auralite® auramode® aura-tTM aurastat®

Heat Water vapour Gases and contaminants Odours

10 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Product Codes Drawing & Dimensions HRV1.35 Q Plus B Eco Enthalpy Eco-aura controls ready - TP418BE/LH (left hand config) or 600 TP418BE/RH (right hand config) - Energy Rating A 600 Filters: XP40032/099 - ISO Coarse 55% (G3) filters fitted as standard (UK only). 300 XP46022/099 - ISO Coarse 60% (G4) filters fitted on request (Europe fitted as standard).

Standards 430 EU RoHS Directive compliant.

Conforms to requirements of EC council directives 100 relating to Electromagnetic Compatibility and 285 Uninstalled Electrical Safety: 295 Installed 2006/95/EC (LVD), 2004/108/EC (EMC) EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/ A1:2004. CE Marked. Specification Heat Cell 600mm wide x 430mm high Technical Data Features & Benefits Dimensions: 3 (excluding ports) x 285mm deep (295mm with (Typical conditions at 140m /h) ÆÆ No transfer of gases or pollutants mounting bracket) ÆÆ Heat change rate 80 % - only heat and steam are transferred by the membrane Weight: 18kg ÆÆ Degree of moisture change 70 % ÆÆ Long life cycle - permanent ÆÆ Leakage at 100 Pa < 1 % Finish: White Paint transmission parameters ÆÆ Temperature stability - 25°C Materials: ÆÆ Minimum leakage up to 65°C Housing: Zintec sheet steel housing, powder coated ÆÆ Optimum flow behaviour, low white pressure loss Internals: Expanded polypropylene (EPP) ÆÆ Frost- and heat-proof Heat exchanger: Selective polymer membrane film Internal insulation: Closed cell foamed ÆÆ High, sensitive and latent Nitrile rubber, class ‘O’ fire rating transmission rate Standard filters: Grade ISO Coarse 55% (G3) ÆÆ Antimicrobial (Microban® - synthetic filters integrated hygiene protection) Guarantee period: 3 years (UK only) ÆÆ Can be cleaned using water Electrical: 230V ~ 50/60Hz, 3A fuse ÆÆ European manufactured heat cell Installation: Install in accordance with regulatory requirements, such as the Domestic Ventilation Compliance Guide (England & Wales) Nominal fan performance and the Residential Ventilation Association 700 recommendations. 16% 10W 30% 15W Maintenance: Service and filter clean/replacement 600 subject to local environment - see product manual. 46% 27W 500 61% 47W Acoustics: Full acoustic data available online www.titon.co.uk/acoustics 76% 77W 400 a) 88% 115W ( P 100% 170W sure 300 e s r P

200

100

0 0 20 40 60 80 l/s 0 50 100 150 200 250 300 m3/h Volume Flow

Acoustic Data

dB(A) @ 3m Hemispherical dB(A) @ 3m Spherical Product Airflow Induct Inlet Induct Outlet Casing Breakout Casing Breakout

22l/s @ 12Pa 28 39 19 16

HRV1.35 Q Plus Eco 39l/s @ 38Pa 40 52 29 26

60l/s @ 100Pa 47 61 36 33

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 11 Features & Benefits

ÆÆ Highly versatile compact unit ÆÆ Extremely low Specific Fan Power; down to 0.49 W/l/s ÆÆ Highly efficient heat exchanger; up to 89% ÆÆ Airflow up to 100 l/s (359m3/h) at 100 Pa ÆÆ Accepts 125mm ducting no adaptors required ÆÆ Intelligent frost protection, stepped reduction of supply air rates prevents HRV unit from freezing ÆÆ ISO Coarse 55% (G3) filters as standard with For use in small to ISO Coarse 60% (G4) as an option

HRV1.6 Q Plus HRV1.6 medium sized dwellings ÆÆ Fully adjustable boost overrun timer 0-60 minutes; can be used with nonlatching The enhanced capacity HRV1.6 Q Plus continuously (momentary) switches to prevent unit from running whole-house ventilation unit with heat recovery being accidentally left in boost mode is independently tested by the BRE maintains an ultra compact size despite its improved results. ÆÆ Volt free switching control Combining extremely low power consumption and a ÆÆ Intelligent controller, quick and easy to highly efficient heat exchanger, this unit enhances SAP commission performance via Appendix Q, and yet remains versatile ÆÆ Lightweight for easy handling enough in size to be equally as functional in larger Æ apartments as it is in small to medium sized dwellings. Æ Quick fix mounting bracket ÆÆ On board aura-tTM capabilities The Eco versions offer a 100% airflow diverting Summer Bypass, recognised and listed in the UK Product ÆÆ Patented Characteristics Database. They also include intelligent ÆÆ Independent fan adjustment humidity options and can be fitted with the auralite® status indicator (HMB and B models) or the auramode®, aurastat® ÆÆ Effective in reducing pollutants in the home or aura-tTM controllers (B models only). and improving Indoor Air Quality (IAQ), therefore reducing the risk of Toxic Home Syndrome

Eco Versions: ÆÆ Intelligent Summer Bypass & humidity controls ÆÆ SUMMERboost® facility Ultra energy efficient Heat Recovery Ventilation unit Recovery efficient Heat Ultra energy ÆÆ Compatible with Eco-aura range; aurastat® auramode® and aura-tTM controllers and auralite® (TP519) status indicator. ÆÆ Duct heater control (requires independent power supply) ÆÆ Available in left and right handed configurations ÆÆ BMS compatible via RS485

auralite® auramode® aura-tTM aurastat®

12 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Product Codes Drawing & Dimensions HRV1.6 Q Plus B Eco-aura controls ready - TP419B/LH (left hand config) or TP419B/RH (right hand config) - Energy Rating A+ 710 *TP419BC - Energy Rating A+ (*Special orders only)

Filters: 600 XP40133/99 - ISO Coarse 55% (G3) filters fitted as standard (UK only). 300 XP46133/099 - ISO Coarse 60% (G4) filters fitted on request (Europe fitted as standard). XP46222/099 - ISO Coarse 55% (G3)/ISO ePM1 55% (F7) filters available on request. 505 XP46232/099 - ISO Coarse 60% (G4) filters/ISO ePM1 55% (F7) filters available on request. 100

Standards 353 Uninstalled Conforms to requirements of UK statutory Building 363 Installed Regulations and Technical Standards for Ventilation and BRE 398. SAP Appendix Q tested Performance (https://www.ncm-pcdb.org.uk/sap/pcdbsearch. The figures and compliance levels below relate to current SAP requirements. jsp?pid=34) Revised SAP guidance will have an effect on performance and up-to-date figures can be found on the relevant product page at www.titon.co.uk. Exceeds requirements of Building Regulations Approved Document L (England & Wales). Exhaust terminal Fan speed Specific fan Heat EU RoHS Directive compliant. power exchange efficiency configuration* setting (W/l/s) (%)

Conforms to requirements of EC council directives Kitchen + 1 100% 0.49 89 relating to Electromagnetic Compatibility and additional wet room variable Electrical Safety: Kitchen + 2 100% 0.49 89 2006/95/EC (LVD), 2004/108/EC (EMC) additional wet rooms variable EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/ Kitchen + 3 100% 0.53 87 A1:2004. additional wet rooms variable Kitchen + 4 100% CE Marked. 0.63 86 additional wet rooms variable Specification Kitchen + 5 100% 0.75 85 Dimensions: 600mm wide x 505mm high additional wet rooms variable (excluding ports) x 353mm deep (363mm with Kitchen + 6 100% 0.87 84 mounting bracket) additional wet rooms variable Kitchen + 7 100% Weight: 22kg 1.03 83 additional wet rooms variable Finish: White Paint Materials: Figures taken from the BRE Test Results Housing: Zintec sheet steel housing, powder *Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance coated white requirements. Internals: Expanded polypropylene (EPP) Heat exchanger: Polystyrene Nominal fan performance Internal insulation: Closed cell foamed Nitrile rubber, class ‘O’ fire rating 1000 Standard filters: Grade ISO Coarse 55% (G3) 900 synthetic filters. 18 6 800 30 11 Guarantee period: 3 years (UK only) 41 21 700 53 37 230V ~ 50/60Hz, 3A fuse Electrical: 600 65 62 77 97 Installation: Install in accordance with 500 88 141 regulatory requirements, such as the Domestic 400 100 185 Ventilation Compliance Guide (England & Wales) and the Residential Ventilation Association 300 recommendations. 200 Maintenance: Service and filter clean/replacement 100 subject to local environment - see product manual. 0 0 20 40 60 80 100 120 100 200 300 400

*@FID (0 Pa) All units offer 100% variable speed control. Performance curves for Eco version. Acoustic Data

dB(A) @ 3m Hemispherical dB(A) @ 3m Spherical Product % of Airflow Max flow Casing Induct Inlet Induct Outlet Breakout Casing Breakout 41% 44l/s @ 17Pa 33 42 18 15

HRV1.6 Q Plus Eco 65% 71l/s @ 54Pa 44 50 30 27

100% 98l/s @ 100Pa 54 63 43 40

For full frequency acoustic data at various speeds please see www.titon.co.uk. All acoustic data is third party tested at Sound Research Laboratories (SRL) Ltd.

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 13 Features & Benefits

ÆÆ Highly versatile compact unit ÆÆ Extremely low Specific Fan Power; down to 0.41 W/l/s ÆÆ Highly efficient heat exchanger; up to 91% ÆÆ Airflow up to 80 l/s (288m3/h) at 100 Pa ÆÆ Accepts 125mm or 150mm diameter ducting, no adaptors required ÆÆ Intelligent frost protection, stepped reduction of supply air rates prevents HRV unit from freezing ÆÆ ISO Coarse 55% (G3) filters as standard with For use in small to ISO Coarse 60% (G4) as an option medium sized dwellings ÆÆ Fully adjustable boost overrun timer 0-60 minutes; can be used with nonlatching HRV1.75 Q Plus HRV1.75 The enhanced capacity HRV1.75 Q Plus continuously (momentary) switches to prevent unit from running whole-house ventilation unit with heat recovery being accidentally left in boost mode is independently tested by the BRE maintains an ultra compact size despite its improved results. ÆÆ Setback facility to reduce ventilation where local regulations allow Combining extremely low power consumption and a highly efficient heat exchanger, this unit enhances SAP ÆÆ Volt free switching control performance via Appendix Q, and yet remains versatile ÆÆ Intelligent controller, quick and easy to enough in size to be equally as functional in larger commission apartments as it is in small to medium sized dwellings. ÆÆ Lightweight for easy handling The Eco versions offer a 100% airflow diverting Summer ÆÆ Re-usable plastic filter frames Bypass, recognised and listed in the UK Product Characteristics Database. They also include intelligent ÆÆ Quick fix mounting bracket auralite® humidity options and can be fitted with the status ÆÆ On board aura-tTM capabilities indicator (HMB and B models) or the auramode®, aurastat® or aura-tTM controllers (B models only). ÆÆ Patented ÆÆ Independent fan adjustment ÆÆ Effective in reducing pollutants in the home and improving Indoor Air Quality (IAQ), therefore reducing the risk of Toxic Home Syndrome

Ultra energy efficient Heat Recovery Ventilation unit Recovery efficient Heat Ultra energy Eco Versions: ÆÆ Intelligent Summer Bypass & humidity controls ÆÆ SUMMERboost® facility ÆÆ Compatible with Eco-aura range; aurastat® auramode® and aura-tTM controllers and auralite® (TP519) status indicator. ÆÆ Duct heater control (requires independent power supply) ÆÆ Available in left and right handed configurations ÆÆ BMS compatible via RS485

auralite® auramode® aura-tTM aurastat®

14 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Product Codes Drawing & Dimensions HRV1.75 Q Plus B Eco-aura controls ready - TP414B/LH (left hand config) or (right hand config) - Energy Rating A+ TP414B/RH 860

Filters: 715 XP40133/099 - ISO Coarse 55% (G3) filters fitted as standard (UK only). XP46133/099 - ISO Coarse 60% (G4) filters fitted on request (Europe fitted as standard). 300 XP46222/099 - ISO Coarse 55% (G3)/ISO ePM1 55% (F7) filters available on request. XP46232/099 - ISO Coarse 60% (G4) filters/ISO 490 ePM1 55% (F7) filters available on request. Standards Conforms to requirements of UK statutory Building 100 415 Uninstalled Regulations and Technical Standards for Ventilation 426 Installed and BRE 398. SAP Appendix Q tested (https://www.ncm-pcdb.org.uk/sap/pcdbsearch. jsp?pid=34) Performance Exceeds requirements of Building Regulations Approved Document L (England & Wales). The figures and compliance levels below relate to current SAP requirements. Revised SAP guidance will have an effect on performance and up-to-date EU RoHS Directive compliant. figures can be found on the relevant product page at www.titon.co.uk. Conforms to requirements of EC council directives relating to Electromagnetic Compatibility and Exhaust terminal Fan speed Specific fan Heat Electrical Safety: configuration* setting power exchange efficiency 2006/95/EC (LVD), 2004/108/EC (EMC) (W/l/s) (%) EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/ Kitchen + 1 100% 0.41 91 A1:2004. additional wet room variable Kitchen + 2 100% CE Marked. 0.42 90 additional wet rooms variable Specification Kitchen + 3 100% 0.49 90 Dimensions: 715mm wide x 490mm high additional wet rooms variable (excluding ports) x 415mm deep (426mm with Kitchen + 4 100% mounting bracket) 0.59 89 additional wet rooms variable : 24kg Weight Kitchen + 5 100% 0.73 88 Finish: White Paint additional wet rooms variable Kitchen + 6 100% 0.90 88 Materials: additional wet rooms variable Housing: Zintec sheet steel housing, powder coated white Figures taken from the BRE Test Results Internals: Expanded polypropylene (EPP) *Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance Heat exchanger: Polystyrene requirements. Internal insulation: Closed cell foamed Nitrile rubber, class ‘O’ fire rating Standard filters: Grade G3 synthetic filters. Guarantee period: 3 years (UK only) Nominal fan performance Electrical: 230V ~ 50/60Hz, 3A fuse Installation: Install in accordance with regulatory requirements, such as the Domestic 1 21 10 Ventilation Compliance Guide (England & Wales) 2 35 16 and the Residential Ventilation Association 3 50 28 recommendations. 4 65 49 5 79 79 Maintenance: Service and filter clean/replacement 6 93 122 subject to local environment - see product manual. 7 100 128

*@FID (0 Pa) All units offer 100% variable speed control. Performance curves for Eco version. Acoustic Data

dB(A) @ 3m Hemispherical dB(A) @ 3m Spherical Product % of Airflow Max flow Casing Induct Inlet Induct Outlet Breakout Casing Breakout 39% 30l/s @ 18Pa 26 36 22 19

HRV1.75 Q Plus Eco 60% 47l/s @ 47Pa 31 46 22 19

100% 78l/s @ 100Pa 40 54 30 27

For full frequency acoustic data at various speeds please see www.titon.co.uk. All acoustic data is third party tested at Sound Research Laboratories (SRL) Ltd.

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 15 Features & Benefits ÆÆ Compact unit ÆÆ Extremely low Specific Fan Power; down to 0.56 W/l/s (Eco version) ÆÆ Highly efficient heat exchanger; up to 90% ÆÆ Airflow up to 88 l/s (318m3/h) at 100 Pa ÆÆ Lightweight for easy handling ÆÆ Intelligent controller, quick and easy to commission ÆÆ Constant volume fans ÆÆ Accepts 150mm diameter ducting, no

HRV2 Q Plus HRV2 adaptors required For use in medium to ÆÆ Independent fan adjustment large sized dwellings ÆÆ Intelligent frost protection, stepped reduction of supply air rates prevents HRV unit from The enhanced capacity HRV2 Q Plus continuously freezing running whole-house ventilation unit with heat recovery Æ is independently tested by the BRE. The HRV2 Q Plus Æ Enthaply Heat Cell option available MVHR unit gives cutting edge performance usually only ÆÆ Setback facility to reduce ventilation where associated with much larger and more costly products. local regulations allow The combination of very low power consumption and a highly ÆÆ Fully adjustable boost overrun timer 0-60 efficient heat exchanger is specifically designed to enhance minutes; can be used with nonlatching SAP performance via Appendix Q, yet small enough to be (momentary) switches to prevent unit from easily incorporated into medium sized dwellings. being accidentally left in boost mode Æ Volt free switching control The Eco versions offer a 100% airflow diverting Summer Æ Bypass, recognised and listed in the UK Product ÆÆ Re-usable plastic filter frames Characteristics Database. They also include intelligent ÆÆ Quick fix mounting bracket humidity options and can be fitted with the auralite® status Æ aura-t indicator (HMB and B models) or the auramode®, aurastat® or Æ On board TM capabilities aura-tTM controllers (B models only). ÆÆ Patented ÆÆ ISO Coarse 55% (G3) filters as standard, ISO Coarse 60% (G4) as an option. ÆÆ Effective in reducing pollutants in the home and improving Indoor Air Quality (IAQ), therefore reducing the risk of Toxic Home Syndrome Ultra energy efficient Heat Recovery Ventilation unit Recovery efficient Heat Ultra energy Basic version: ÆÆ Summer mode

Eco Versions: ÆÆ Intelligent Summer Bypass & humidity controls ÆÆ SUMMERboost® facility ÆÆ Compatible with Eco-aura range; aurastat® auramode® and aura-tTM controllers and auralite® (TP519) status indicator. ÆÆ Duct heater control (requires independent power supply) ÆÆ Available in left and right handed configurations auralite® Æ BMS compatible via RS485 auramode® Æ aura-tTM aurastat®

16 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Product Codes Drawing & Dimensions HRV2 Q Plus B Eco-aura controls ready - TP411B/LH (left hand config) or (right hand config) - Energy Rating A+ TP411B/RH 860 TP411BC - Energy Rating A+ 715 Filters: XP40133/099 - ISO Coarse 55% (G3) filters fitted as standard (UK only). XP46133/099 - ISO Coarse 60% (G4) filters fitted 300 on request (Europe fitted as standard). XP46222/099 - ISO Coarse 55% (G3)/ISO ePM1 55% (F7) filters available on request. 490 XP46232/099 - ISO Coarse 60% (G4) filters/ISO ePM1 55% (F7) filters available on request.

Standards 100 Conforms to requirements of UK statutory Building 415 Uninstalled Regulations and Technical Standards for Ventilation 426 Installed and BRE 398. SAP Appendix Q tested (https://www.ncm-pcdb.org.uk/sap/pcdbsearch. jsp?pid=34) Performance Exceeds requirements of Building Regulations The figures and compliance levels below relate to current SAP requirements. Approved Document L (England & Wales). Revised SAP guidance will have an effect on performance and up-to-date EU RoHS Directive compliant. figures can be found on the relevant product page at www.titon.co.uk. Conforms to requirements of EC council directives Exhaust terminal Fan speed Specific fan Heat relating to Electromagnetic Compatibility and configuration* setting power exchange efficiency Electrical Safety: (W/l/s) (%) 2006/95/EC (LVD), 2004/108/EC (EMC) Kitchen + 2 100% 0.56 90 EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/ additional wet rooms variable A1:2004. Kitchen + 3 100% 0.62 90 CE Marked. additional wet rooms variable Kitchen + 4 100% Specification 0.70 89 Dimensions: 715mm wide x 490mm high additional wet rooms variable (excluding ports) x 415mm deep (426mm with Kitchen + 5 100% 0.79 89 mounting bracket) additional wet rooms variable Kitchen + 6 100% Weight: 24kg 0.91 88 additional wet rooms variable Finish: White Paint Kitchen + 7 100% 1.07 87 Materials: additional wet rooms variable Housing: Zintec sheet steel housing, powder coated Figures taken from the BRE Test Results white Internals: Expanded polypropylene (EPP) *Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance Heat exchanger: Polystyrene requirements. Internal insulation: Closed cell foamed Nitrile rubber, class ‘O’ fire rating Standard filters: Grade ISO Coarse 55% (G3) Nominal fan performance synthetic filters. Guarantee period: 3 years (UK only) Electrical: 230V ~ 50/60Hz, 3A fuse 24 11 Installation: Install in accordance with 31 13 regulatory requirements, such as the Domestic Ventilation Compliance Guide (England & Wales) 39 17 and the Residential Ventilation Association 49 24 recommendations. 61 34 72 47 Maintenance: Service and filter clean/replacement 86 71 subject to local environment - see product manual. 100 108

*@FID (0 Pa) All units offer 100% variable speed control. Performance curves for Eco version. Acoustic Data

dB(A) @ 3m Hemispherical dB(A) @ 3m Spherical Product % of Airflow Max flow Casing Induct Inlet Induct Outlet Breakout Casing Breakout 33% 27l/s @ 8Pa 20 33 16 13

HRV2 Q Plus Eco 70% 57l/s @ 56Pa 35 51 32 29

100% 81l/s @ 100Pa 41 56 37 34

For full frequency acoustic data at various speeds please see www.titon.co.uk. All acoustic data is third party tested at Sound Research Laboratories (SRL) Ltd.

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 17 Features & Benefits

ÆÆ Constant volume fans ÆÆ Highly efficient enthalpy counter flow heat exchanger ÆÆ Intelligent controller, quick and easy to commission ÆÆ Accepts 125mm or 150mm diameter ducting, no adaptors required

- Enthalpy ÆÆ Independent fan adjustment ÆÆ Intelligent automated control of summer bypass, frost protection and humidity For use in medium to functions ÆÆ Setback facility to reduce ventilation where large sized dwellings local regulations allow The HRV2 Q Plus MVHR unit gives cutting edge ÆÆ Fully adjustable boost overrun timer 0-60 performance usually only associated with much larger minutes; can be used with non-latching

Q Plus and more costly products. (momentary) switches to prevent unit from The combination of very low power consumption and a being accidentally left in boost mode highly efficient heat exchanger is small enough to be easily ÆÆ Volt free switching control incorporated into medium sized dwellings. ÆÆ Re-usable plastic filter frames The counter flow enthalpy heat exchanger has a selective ÆÆ Quick fix mounting bracket polymer membrane film to achieve low air leakage levels while providing moisture recovery from the exhaust air. ÆÆ On board aura-tTM capabilities These models are ideal for living areas with low humidity, ÆÆ Patented

HRV2 HRV2 avoiding frost build up at low temperatures, they also have an antimicrobial membrane and long life cycle. ÆÆ ISO Coarse 55% (G3) filters as standard, ISO Coarse 60% (G4) as an option. The Eco versions offer a 100% airflow diverting Summer Bypass. They also include intelligent humidity options and ÆÆ Effective in reducing pollutants in the home can be fitted with auralite® status indicator or the auramode® and improving Indoor Air Quality (IAQ), and aurastat® controllers. therefore reducing the risk of Toxic Home Syndrome

Eco BE Models: ÆÆ Compatible with Eco-aura range; aurastat® auramode® and aura-tTM controllers and auralite® (TP519) status indicator. ÆÆ Duct heater control (requires independent power supply) ÆÆ Available in left and right handed configurations ÆÆ BMS compatible via RS485 Ultra energy efficient Heat Recovery Ventilation unit efficient Heat RecoveryUltra energy

auralite® auramode® aura-tTM aurastat®

Heat Water vapour Gases and contaminants Odours

18 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Product Codes Drawing & Dimensions HRV2 Q Plus B Eco Enthalpy Eco-aura controls ready - TP411BE/LH (left hand config) or 860 TP411BE/RH (right hand config) - Energy Rating A+ 715 Filters: XP40133/099 - ISO Coarse 55% (G3) filters fitted as standard (UK only). 300 XP46133/099 - ISO Coarse 60% (G4) filters fitted on request (Europe fitted as standard).

XP46222/099 - ISO Coarse 55% (G3)/ISO ePM1 490 55% (F7) filters available on request. XP46232/099 - ISO Coarse 60% (G4) filters/ISO ePM1 55% (F7) filters available on request. 100 415 Uninstalled Standards 426 Installed EU RoHS Directive compliant. Conforms to requirements of EC council directives relating to Electromagnetic Compatibility and Electrical Safety: Heat Cell 2006/95/EC (LVD), 2004/108/EC (EMC) Technical Data Features & Benefits EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/ 3 (Typical conditions at 140m /h) ÆÆ No transfer of gases or pollutants A1:2004. ÆÆ Heat change rate 80 % - only heat and steam are CE Marked. transferred by the membrane ÆÆ Degree of moisture change 70 % Specification ÆÆ Long life cycle - permanent ÆÆ Leakage at 100 Pa < 1 % Dimensions: 715mm wide x 490mm high transmission parameters (excluding ports) x 415mm deep (426mm with ÆÆ Temperature stability - 25°C ÆÆ Minimum leakage mounting bracket) up to 65°C ÆÆ Optimum flow behaviour, low Weight: 27.5kg pressure loss Finish: White Paint ÆÆ Frost- and heat-proof

Materials: ÆÆ High, sensitive and latent transmission rate Housing: Zintec sheet steel housing, powder coated Æ ® white Æ Antimicrobial (Microban - Internals: Expanded polypropylene (EPP) integrated hygiene protection) Heat exchanger: Selective polymer membrane film ÆÆ Can be cleaned using water Internal insulation: Closed cell foamed ÆÆ European manufactured heat cell Nitrile rubber, class ‘O’ fire rating Standard filters: Grade ISO Coarse 55% (G3) synthetic filters. Nominal fan performance Guarantee period: 3 years (UK only) 500 Electrical: 230V ~ 50/60Hz, 3A fuse 24% 12W 450 32% 13W Installation: Install in accordance with 41% 18W regulatory requirements, such as the Domestic 400 52% 24W Ventilation Compliance Guide (England & Wales) 350 and the Residential Ventilation Association 61% 35W recommendations. 300 76% 50W 91% 73W Maintenance: Service and filter clean/replacement 250 100% 98W subject to local environment - see product manual. 200 Pressure (Pa)

150

100

50

0 0 20 40 60 80 100 l/s 0 50 100 150 200 250 300 350 m3/h Volume Flow Acoustic Data

dB(A) @ 3m Hemispherical dB(A) @ 3m Spherical Product Airflow Induct Inlet Induct Outlet Casing Breakout Casing Breakout

27l/s @ 8Pa 20 33 16 13

HRV2 Q Plus Eco 57l/s @ 56Pa 35 51 32 29

81l/s @ 100Pa 41 56 37 34

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 19 Features & Benefits ÆÆ Highly compact, making a highly versatile unit ÆÆ Lightweight for easy handling ÆÆ Extremely low Specific Fan Power; down to 0.52 W/l/s ÆÆ Highly efficient heat exchanger; up to 91% ÆÆ Airflow up to 98 l/s (352m3/h) at 100 Pa ÆÆ Intelligent controller, quick and easy to commission ÆÆ Accepts 150mm diameter ducting, no adaptors required For use in medium to ÆÆ Independent fan adjustment large sized dwellings ÆÆ Intelligent frost protection, stepped reduction of supply air rates prevents HRV unit from

HRV2.85 Q Plus HRV2.85 The enhanced capacity HRV2.85 Q Plus continuously freezing running whole-house ventilation unit with heat recovery ÆÆ Setback facility to reduce ventilation where has been specifically designed to give improved local regulations allow performance over older models, in line with new build ÆÆ Fully adjustable boost overrun timer 0-60 design requirements. It is independently tested by the minutes; can be used with non-latching BRE. (momentary) switches to prevent unit from Combining extremely low power consumption and a highly being accidentally left in boost mode efficient heat exchanger, the HRV2.85 Q Plus is specifically ÆÆ Re-usable plastic filter frames designed to enhance SAP performance via Appendix Q, yet still small enough to be easily incorporated into medium or ÆÆ Volt free switching control large sized dwellings. ÆÆ ISO Coarse 55% (G3) filters as standard with ISO Coarse 60% (G4) as an option The Eco versions offer a 100% airflow diverting Summer Bypass, recognised and listed in the UK Product ÆÆ Quick fix mounting bracket Characteristics Database. They also include intelligent ÆÆ On board aura-tTM capabilities humidity options and can be fitted with the auralite® status Æ indicator (HMB and B models) or the auramode®, aurastat® Æ Patented features and design or aura-tTM controllers (B models only). ÆÆ Effective in reducing pollutants in the home and improving Indoor Air Quality (IAQ), therefore reducing the risk of Toxic Home Syndrome

Eco Versions:

Ultra energy efficient Heat Recovery Ventilation unit Recovery efficient Heat Ultra energy ÆÆ Intelligent Summer Bypass & humidity controls ÆÆ SUMMERboost® facility ÆÆ Compatible with Eco-aura range; aurastat® auramode® and aura-tTM controllers and auralite® (TP519) status indicator. ÆÆ Duct heater control (requires independent power supply) ÆÆ Available in left and right handed configurations ÆÆ BMS compatible via RS485

auralite® auramode® aura-tTM aurastat®

20 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Product Codes Drawing & Dimensions HRV2.85 Q Plus B Eco-aura controls ready - TP417B/LH (left hand config) or TP417B/RH (right hand config) - Energy Rating A+ TP417BC - Energy Rating A+ 860 715 Filters: XP40133/099 - ISO Coarse 55% (G3) filters fitted as standard (UK only). XP46133/099 - ISO Coarse 60% (G4) filters fitted on request (Europe fitted as standard). 300 XP46222/099 - ISO Coarse 55% (G3)/ISO ePM1 55% (F7) filters available on request. XP46232/099 - ISO Coarse 60% (G4) filters/ISO 490 ePM1 55% (F7) filters available on request. Standards 100 Conforms to requirements of UK statutory Building 415 Uninstalled Regulations and Technical Standards for Ventilation 426 Installed and BRE 398. SAP Appendix Q tested (https://www.ncm-pcdb.org.uk/sap/pcdbsearch. jsp?pid=34) Performance Exceeds requirements of Building Regulations Approved Document L (England & Wales). The figures and compliance levels below relate to current SAP requirements. Revised SAP guidance will have an effect on performance and up-to-date EU RoHS Directive compliant. figures can be found on the relevant product page at www.titon.co.uk. Conforms to requirements of EC council directives relating to Electromagnetic Compatibility and Exhaust terminal Fan speed Specific fan Heat Electrical Safety: configuration* setting power exchange efficiency 2006/95/EC (LVD), 2004/108/EC (EMC) (W/l/s) (%) EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/ Kitchen + 1 100% 0.56 91 A1:2004. additional wet room variable CE Marked. Kitchen + 2 100% 0.52 90 Specification additional wet rooms variable Kitchen + 3 100% 0.53 90 Dimensions: 715mm wide x 490mm high additional wet rooms variable (excluding ports) x 415mm deep (426mm with Kitchen + 4 100% mounting bracket) 0.62 89 additional wet rooms variable Weight: 24kg Kitchen + 5 100% 0.71 88 Finish: White Paint additional wet rooms variable Kitchen + 6 100% 0.83 88 Materials: additional wet rooms variable Kitchen + 7 100% Housing: Zintec sheet steel housing, powder coated 0.97 87 white additional wet rooms variable Internals: Expanded polypropylene (EPP) Heat exchanger: Polystyrene Figures taken from the BRE Test Results Internal insulation: Closed cell foamed Nitrile *Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance rubber, class ‘O’ fire rating requirements. Standard filters: Grade ISO Coarse 55% (G3) synthetic filters. Guarantee period: 3 years (UK only) Nominal fan performance Electrical: 230V ~ 50/60Hz, 3A fuse 450 Installation: Install in accordance with 400 regulatory requirements, such as the Domestic 12 7 Ventilation Compliance Guide (England & Wales) 23 11 and the Residential Ventilation Association 350 38 20 recommendations. 300 53 37 Maintenance: Service and filter clean/replacement 250 68 64 subject to local environment - see product manual. 80 92 200 92 145 150 100 167

100

50

0

*@FID (0 Pa) All units offer 100% variable speed control. Performance curves for Eco version. Acoustic Data

dB(A) @ 3m Hemispherical dB(A) @ 3m Spherical Product % of Airflow Max flow Casing Induct Inlet Induct Outlet Breakout Casing Breakout 31% 29l/s @ 7Pa 22 33 14 11

HRV2.85 Q Plus Eco 66% 61l/s @ 40Pa 34 47 24 21

100% 93l/s @ 100Pa 42 56 34 31

For full frequency acoustic data at various speeds please see www.titon.co.uk. All acoustic data is third party tested at Sound Research Laboratories (SRL) Ltd.

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 21 Features & Benefits

ÆÆ Extremely low Specific Fan Power; down to 0.66 W/l/s ÆÆ Constant volume fans ÆÆ Highly efficient heat exchanger; up to 90% ÆÆ Airflow up to 118 l/s (423m3/h) at 100 Pa ÆÆ Intelligent controller, quick and easy to commission ÆÆ Fully adjustable boost overrun timer 0- 60 minutes; use with nonlatching (momentary) switches to prevent unit from being accidentally left in boost mode HRV3 Q Plus HRV3 For use in large dwellings ÆÆ Accepts 150mm diameter ducting, no adaptors required Suitable for larger dwellings, the HRV3 Q Plus Æ continuously running whole-house ventilation unit with Æ Intelligent frost protection, stepped reduction heat recovery is independently tested by the BRE. The of supply air rates prevents HRV unit from freezing HRV3 Q Plus gives cutting edge performance usually only associated with much larger and more costly ÆÆ Setback facility to reduce ventilation where products. local regulations allow The combination of very low power consumption and a highly ÆÆ Lightweight for easy handling efficient heat exchanger is specifically designed to enhance ÆÆ Volt free switching control SAP performance via Appendix Q, yet small enough to be Æ ISO Coarse 55% (G3) filters as standard with easily incorporated into medium sized dwellings. Æ ISO Coarse 60% (G4) as an option The Eco versions offer a 100% airflow diverting Summer ÆÆ Re-usable plastic filter frames Bypass, recognised and listed in the UK Product Æ Characteristics Database. They also include intelligent Æ Quick fix mounting bracket humidity options and can be fitted with the auralite® status ÆÆ On board aura-tTM capabilities indicator (HMB and B models) or the auramode®, aurastat® or ÆÆ Patented aura-tTM controllers (B models only). ÆÆ Independent fan adjustment ÆÆ Effective in reducing pollutants in the home and improving Indoor Air Quality (IAQ), therefore reducing

Basic version: ÆÆ Summer Mode Ultra energy efficient Heat Recovery Ventilation unit Recovery efficient Heat Ultra energy

Eco Versions: ÆÆ Intelligent Summer Bypass & humidity controls

ÆÆ SUMMERboost® facility ÆÆ Compatible with Eco-aura range; aurastat® auramode® and aura-tTM controllers and auralite® (TP519) status indicator. ÆÆ Duct heater control (requires independent power supply) ÆÆ Available in left and right handed configurations ÆÆ Enthaply Heat Cell option available auralite® auramode® ÆÆ BMS compatible via RS485 aura-tTM aurastat®

22 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Product Codes Drawing & Dimensions HRV3 Q Plus B Eco-aura controls ready - TP412B/LH (left hand config) or TP412B/RH (right hand config) - Energy Rating A TP412BC - Energy Rating A 860 715 Filters: XP40133/099 - ISO Coarse 55% (G3) filters fitted as standard (UK only). XP46133/099 - ISO Coarse 60% (G4) filters fitted 300 on request (Europe fitted as standard). XP46222/099 - ISO Coarse 55% (G3)/ISO ePM1 55% (F7) filters available on request. 490 XP46232/099 - ISO Coarse 60% (G4) filters/ISO ePM1 55% (F7) filters available on request.

Standards 100 Conforms to requirements of UK statutory Building 415 Uninstalled Regulations and Technical Standards for Ventilation 426 Installed and BRE 398. SAP Appendix Q tested (https://www.ncm-pcdb.org.uk/sap/pcdbsearch. jsp?pid=34) Performance Exceeds requirements of Building Regulations The figures and compliance levels below relate to current SAP requirements. Approved Document L (England & Wales). Revised SAP guidance will have an effect on performance and up-to-date EU RoHS Directive compliant. figures can be found on the relevant product page at www.titon.co.uk. Conforms to requirements of EC council directives Specific fan Heat relating to Electromagnetic Compatibility and Exhaust terminal Fan speed power exchange efficiency Electrical Safety: configuration* setting (W/l/s) (%) 2006/95/EC (LVD), 2004/108/EC (EMC) Kitchen + 3 100% EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/ 0.66 90 A1:2004. additional wet rooms variable Kitchen + 4 100% CE Marked. 0.78 89 additional wet rooms variable Specification Kitchen + 5 100% 0.91 88 Dimensions: 715mm wide x 490mm high additional wet rooms variable (excluding ports) x 415mm deep (426mm with Kitchen + 6 100% mounting bracket) 1.05 88 additional wet rooms variable Weight: 24.5kg Kitchen + 7 100% 1.22 87 Finish: White Paint additional wet rooms variable Materials: Figures taken from the BRE Test Results Housing: Zintec sheet steel housing, powder coated *Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance white requirements. Internals: Expanded polypropylene (EPP) Heat exchanger: Polystyrene Internal insulation: Closed cell foamed Nitrile rubber, class ‘O’ fire rating Standard filters: Grade ISO Coarse 55% (G3) synthetic filters. Nominal fan performance Guarantee period: 3 years (UK only) Electrical: 230V ~ 50/60Hz, 5A fuse 800 Installation: Install in accordance with 700 regulatory requirements, such as the Domestic 22 14 Ventilation Compliance Guide (England & Wales) 600 33 21 and the Residential Ventilation Association 44 32 recommendations. 500 56 50 69 78 Maintenance: Service and filter clean/replacement 400 subject to local environment - see product manual. 81 112 300 94 151 100 184 200

100

0 0 20 40 60 80 100 120

*@FID (0 Pa). All units offer 100% variable speed control. Performance curves for Eco version. Acoustic Data

dB(A) @ 3m Hemispherical dB(A) @ 3m Spherical Product % of Airflow Max flow Casing Induct Inlet Induct Outlet Breakout Casing Breakout 33% 36l/s @ 10Pa 25 35 21 18

HRV3 Q Plus Eco 68% 73l/s @ 48Pa 36 49 29 26

100% 108l/s @ 100Pa 45 57 37 34

For full frequency acoustic data at various speeds please see www.titon.co.uk. All acoustic data is third party tested at Sound Research Laboratories (SRL) Ltd.

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 23 Features & Benefits

ÆÆ Constant volume fans ÆÆ Highly efficient enthalpy counter flow heat exchanger ÆÆ Intelligent controller, quick and easy to commission ÆÆ Fully adjustable boost overrun timer 0- 60 minutes; use with non-latching (momentary) switches to prevent unit from being - Enthalpy accidentally left in boost mode ÆÆ Accepts 125mm or 150mm diameter ducting, no adaptors required For use in large dwellings ÆÆ Intelligent automated control of summer bypass, frost protection and humidity Suitable for larger dwellings, the HRV3 Q Plus functions continuously running whole-house ventilation unit with Æ heat recovery gives cutting edge performance usually Æ Setback facility to reduce ventilation where only associated with much larger and more costly local regulations allow Q Plus products. ÆÆ Lightweight for easy handling The combination of very low power consumption and a ÆÆ Volt free switching control highly efficient heat exchanger is small enough to be easily ÆÆ ISO Coarse 55% (G3) filters as standard, ISO incorporated into medium sized dwellings. Coarse 60% (G4) as an option The counter flow enthalpy heat exchanger has a selective ÆÆ Re-usable plastic filter frames polymer membrane film to achieve low air leakage levels while providing moisture recovery from the exhaust air. ÆÆ Quick fix mounting bracket These models are ideal for living areas with low humidity, ÆÆ On board aura-tTM capabilities HRV3 HRV3 avoiding frost build up at low temperatures, they also have an antimicrobial membrane and long life cycle. ÆÆ Patented Æ The Eco versions offer a 100% airflow diverting Summer Æ Independent fan adjustment Bypass. They also include intelligent humidity options and ÆÆ Effective in reducing pollutants in the home can be fitted with auralite® status indicator or the auramode® and improving Indoor Air Quality (IAQ), and aurastat® controllers. therefore reducing Eco BE Models: ÆÆ Compatible with Eco-aura range; aurastat® auramode® and aura-tTM controllers and auralite® (TP519) status indicator. ÆÆ Duct heater control (requires independent power supply) ÆÆ Available in left and right handed configurations ÆÆ BMS compatible via RS485 Ultra energy efficient Heat Recovery Ventilation unit efficient Heat RecoveryUltra energy

auralite® auramode® aura-tTM aurastat®

Heat Water vapour Gases and contaminants Odours

24 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Product Codes Drawing & Dimensions HRV3 Q Plus B Eco Enthalpy Eco-aura controls ready - TP412BE/LH (left hand config) or 860

TP412BE/RH (right hand config) Energy Rating A 715 Filters: XP40133/99 - ISO Coarse 55% (G3) filters fitted as standard (UK only). 300 XP46133/099 - ISO Coarse 60% (G4) filters fitted on request (Europe fitted as standard).

XP46222/099 - ISO Coarse 55% (G3)/ISO ePM1 490 55% (F7) filters available on request. XP46232/099 - ISO Coarse 60% (G4) filters/ISO ePM1 55% (F7) filters available on request. 100 415 Uninstalled Standards 426 Installed EU RoHS Directive compliant. Conforms to requirements of EC council directives relating to Electromagnetic Compatibility and Electrical Safety: Heat Cell 2006/95/EC (LVD), 2004/108/EC (EMC) Technical Data Features & Benefits EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/ 3 (Typical conditions at 140m /h) ÆÆ No transfer of gases or pollutants A1:2004. CE Marked. ÆÆ Heat change rate 80 % - only heat and steam are transferred by the membrane Specification ÆÆ Degree of moisture change 70 % 715mm wide x 490mm high ÆÆ Long life cycle - permanent Dimensions: ÆÆ Leakage at 100 Pa < 1 % (excluding ports) x 415mm deep (426mm with transmission parameters ÆÆ Temperature stability - 25°C mounting bracket) ÆÆ Minimum leakage up to 65°C Weight: 28kg ÆÆ Optimum flow behaviour, low pressure loss Finish: White Paint ÆÆ Frost- and heat-proof Materials: ÆÆ High, sensitive and latent Housing: Zintec sheet steel housing, powder coated transmission rate white ÆÆ Antimicrobial (Microban® - Internals: Expanded polypropylene (EPP) integrated hygiene protection) Heat exchanger: Selective polymer membrane film Internal insulation: Closed cell foamed Nitrile ÆÆ Can be cleaned using water rubber, class ‘O’ fire rating ÆÆ European manufactured heat cell Standard filters: Grade ISO Coarse 55% (G3) synthetic filters. Guarantee period: 3 years (UK only) Nominal fan performance

Electrical: 230V ~ 50/60Hz, 5A fuse 900 26% 15W Installation: Install in accordance with 800 36% 21W regulatory requirements, such as the Domestic 45% 31W 700 Ventilation Compliance Guide (England & Wales) 50% 40W and the Residential Ventilation Association 600 67% 68W recommendations. 500 84% 104W Maintenance: Service and filter clean/replacement 100% 160W subject to local environment - see product manual. 400 Pressure (Pa) 300

200

100

0 0 20 40 60 80 100 120 140 l/s 0 100 200 300 400 500 m3/h Volume Flow Acoustic Data

dB(A) @ 3m Hemispherical dB(A) @ 3m Spherical Product Airflow Induct Inlet Induct Outlet Casing Breakout Casing Breakout

36l/s @ 10Pa 25 35 21 18

HRV3 Q Plus Eco 73l/s @ 48Pa 36 49 29 26

108l/s @ 100Pa 45 57 37 34

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 25 Features & Benefits

ÆÆ Tested and approved by Passive House to meet their high certification standards ÆÆ Extremely low Specific electric power; down to 0.40 Wh/m3 ÆÆ Constant volume fans ÆÆ Highly efficient heat exchanger; up to 86% ÆÆ Airflow up to 379m3/h at 100 Pa ÆÆ Intelligent controller, quick and easy to commission ÆÆ Fully adjustable boost overrun timer 0-60 minutes; use with nonlatching (momentary) For use in large dwellings switches to prevent unit from being accidentally left in boost mode Suitable for larger dwellings, the HRV3 PH ECOaura ÆÆ Accepts 150mm diameter ducting, no continuously running whole-house ventilation unit with adaptors required heat recovery is independently tested and is Passivhaus ÆÆ Intelligent frost protection certified. The HRV3 PH ECOaura gives cutting edge performance usually only associated with much larger ÆÆ Setback facility to reduce ventilation where and more costly products. local regulations allow ÆÆ Lightweight for easy handling The combination of very low power consumption and a highly efficient heat exchanger is specifically designed to enhance ÆÆ Volt free switching control performance, yet small enough to be easily incorporated into ÆÆ Re-usable plastic filter frames medium sized dwellings. ÆÆ Quick fix mounting bracket Our HRV3 PH ECOaura has 100% airflow diverting Summer ÆÆ Patented Bypass functionality that offers intelligent humidity options ÆÆ Independent fan adjustment and is fitted with either our aurastat® or aura-tTM controllers. ÆÆ Effective in reducing pollutants in the home and improving Indoor Air Quality (IAQ), therefore reducing toxic home syndrome ÆÆ Compatible with Eco-aura controllers; aurastat® and aura-tTM ÆÆ Duct heater control ÆÆ Available in left and right handed configurations

HRV3 PH ECOaura - Passivhaus HRV3 ÆÆ BMS compatible via RS485 Ultra energy efficient Heat Recovery Ventilation unit Recovery efficient Heat Ultra energy

aura-tTM aurastat®

Passive House is a recognised standard for highly efficient products and low energy buildings.

26 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Product Codes Specification *HRV3 PH ECOaura - TP412B PH Dimensions: 715mm wide x 490mm high (excluding ports) x 415mm aura-t™ touch screen controller - TP536 deep (426mm with mounting bracket) Duct Heater Weight: 24.5kg EKA-NV160-1.5 – Ø160mm 1.5kW electric duct heater with temperature control, including remote duct temperature sensor Finish: White Paint EKA-NV150-1.5 – Ø150mm 1.5kW electric duct heater with temperature control, including remote duct temperature sensor Materials: Filters: Housing: Zintec sheet steel housing, powder coated white XP46232/099 - ISO Coarse 60% (G4) filters/ISO ePM1 55% (F7) Internals: Expanded polypropylene (EPP) filters available on request. Heat exchanger: Polystyrene Internal insulation: Closed cell foamed Nitrile rubber, class ‘O’ fire *Controller and Duct Heater need to be purchased with HRV3 PH rating ECOaura to make it fully Passivhaus compliant. Standard filters: ISO ePM1 55% (F7) pleated panel on supply, ISO Coarse 60% (G4) synthetic on extract Standards Guarantee period: 3 years (UK only) Certified Passive House Component (Component-ID 1182vs03) Electrical: 230V ~ 50/60Hz, 5A fuse Conforms to requirements of UK statutory Building Regulations and Technical Standards for Ventilation and BRE 398. Installation: Install in accordance with regulatory requirements, such Exceeds requirements of Building Regulations Approved Document L as the Domestic Ventilation Compliance Guide (England & Wales) (England & Wales). and the Residential Ventilation Association recommendations. EU RoHS Directive compliant. Maintenance: Service and filter clean/replacement subject to local Conforms to requirements of EC council directives relating to environment - see product manual. Electromagnetic Compatibility and Electrical Safety: 2006/95/EC (LVD), 2004/108/EC (EMC) EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/A1:2004. CE Marked.

Drawing & Dimensions

860

715

300

490

100 415 Uninstalled 426 Installed

Performance

800 Nominal Watts* Speed % 22% 14W 700 33% 21W 44% 32W 600 56% 50W 69% 78W 500 81% 112W 94% 151W 400 100% 184W *@FID (0 Pa). All units offer 100% variable speed control.

Pressure (Pa) 300

200

100

0 0 20 40 60 80 100 120 l/s 0 100 200 300 400 m3/h Volume Flow Acoustic Data

dB(A) @ 3m Hemispherical dB(A) @ 3m Spherical Product % of Airflow Max flow Casing Induct Inlet Induct Outlet Breakout Casing Breakout 33% 36l/s @ 10Pa 25 35 21 18

HRV3 PH ECOaura 68% 73l/s @ 48Pa 36 49 29 26

100% 108l/s @ 100Pa 45 57 37 34

Note: Data for HRV3 with ISO Coarse 60% (G4) Filters For full frequency acoustic data at various speeds please see www.titon.co.uk. All acoustic data is third party tested at Sound Research Laboratories (SRL) Ltd.

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 27 Features & Benefits

ÆÆ Extremely low Specific Fan Power; down to 0.48 W/l/s ÆÆ Highly efficient heat exchanger; up to 92% ÆÆ Airlow up to 115 l/s (415m3/h) at 100 Pa ÆÆ Lightweight EPP construction giving high levels of thermal insulation ÆÆ Accepts 150mm diameter ducting ÆÆ Independent fan adjustment ÆÆ Intelligent frost protection, stepped reduction of supply air rates prevents HRV unit from For use in large dwellings freezing

HRV10 Q Plus HRV10 ÆÆ Setback facility to reduce ventilation where The HRV10 Q Plus continuously running whole-house local regulations allow ventilation unit with heat recovery has been specifically ÆÆ Fully adjustable boost overrun timer 0-60 designed to give improved performance over older minutes; can be used with nonlatching models, in line with new build design requirements. (momentary) switches to prevent unit from Combining extremely low power consumption and a highly being accidentally left in boost mode efficient heat exchanger specifically designed to enhance ÆÆ Intelligent controller, quick and easy to SAP performance via Appendix Q and can be incorporated commission into larger apartments or dwellings. ÆÆ EPP moulded 150mm low resistance insulated The Eco versions offer a 100% airflow diverting Summer port adaptors included as standard Bypass, recognised and listed in the UK Product Characteristics Database. They also include intelligent ÆÆ Lightweight for easy handling humidity options and can be fitted with the auralite® status ÆÆ Volt free switching control indicator (HMB and B models) or the auramode®, aurastat® or Æ aura-tTM controllers (B models only). Æ Pleated ISO Coarse 65% (G4) filters as standard. ISO ePM1 55% (F7) on request (Standard unit only) ÆÆ Metal cased version available (HRV10M Q Plus) ÆÆ Quick fix mounting bracket ÆÆ On board aura-tTM capabilities ÆÆ Patented features ÆÆ Effective in reducing pollutants in the home and improving Indoor Air Quality (IAQ), therefore reducing the risk of Toxic Home Ultra energy efficient Heat Recovery Ventilation unit Recovery efficient Heat Ultra energy Syndrome

Eco Versions: ÆÆ Intelligent Summer Bypass & humidity HRV 10 Q Plus controls

ÆÆ SUMMERboost® facility ÆÆ Compatible with Eco-aura range; aurastat® HRV 10M Q Plus auramode® and aura-tTM controllers and auralite® (TP519) status indicator. ÆÆ Duct heater control (requires independent power supply) ÆÆ BMS compatible via RS485

auralite® auramode® aura-tTM aurastat®

28 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Product Codes Drawing & Dimensions HRV10 Q Plus B Eco-aura controls ready - TP480B - Energy Rating A+ - Energy Rating A+ TP480BC 920

HRV10M Q Plus B Eco-aura controls ready - HRV10 Q Plus 790 TP481B - Energy Rating A+ HRV10M Q Plus 800 Filters: XP44023/099 - ISO Coarse 65% (G4) bypass filter set fitted as standard. 400 XP46223/099 - ISO Coarse 65% (G4)/ISO ePM1 55% (F7) filters available on request. HRV10 Q Plus 663 Standards HRV10M Q Plus 675 Conforms to requirements of UK statutory Building Regulations and Technical Standards for Ventilation HRV10 Q Plus 484 and BRE 398. HRV10M Q Plus 460 100 SAP Appendix Q tested (https://www.ncm-pcdb.org.uk/sap/pcdbsearch. jsp?pid=34) Exceeds requirements of Building Regulations Approved Document L (England & Wales). Performance EU RoHS Directive compliant. The figures and compliance levels below relate to current SAP requirements. Conforms to requirements of EC council directives Revised SAP guidance will have an effect on performance and up-to-date relating to Electromagnetic Compatibility and figures can be found on the relevant product page at www.titon.co.uk. Electrical Safety: 2006/95/EC (LVD), 2004/108/EC (EMC) Exhaust terminal Fan speed Specific fan Heat EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/ configuration* setting power exchange efficiency A1:2004. (W/l/s) (%) Kitchen + 1 100% CE Marked. 0.52 92 additional wet room variable Specification Kitchen + 2 100% 0.48 92 Dimensions: HRV10 Q Plus - 790mm wide x additional wet rooms variable 665mm high (excluding ports) x 485mm deep Kitchen + 3 100% (495mm with mounting bracket). HRV10M Q Plus 0.51 92 800mm wide x 675mm high (excluding ports) x additional wet rooms variable 495mm deep (505mm with mounting bracket). Kitchen + 4 100% 0.55 91 additional wet rooms variable Weight: HRV10 Q Plus – 17.5kg, HRV10M Q Plus Kitchen + 5 100% – 31kg. 0.62 91 additional wet rooms variable HRV10 Q Plus – Black EPP, HRV10M Q Finish: Kitchen + 6 100% 0.74 90 Plus – White Paint. additional wet rooms variable Materials: Expanded polypropylene (EPP), Heat Kitchen + 7 100% 0.87 89 Exchanger – Polystyrene, Internal Insulation – additional wet rooms variable Closed cell foamed, Nitrile rubber, class ‘O’ fire Figures taken from the BRE Test Results rating, Standard filters: Grade ISO Coarse 60% (G4) pleated panel filters. NB: Except HRV10.25M *Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance Q Plus Housing – Zintec sheet steel, powder requirements. coated. Guarantee period: 3 years (UK only). Nominal fan performance Electrical: 230V ~ 50/60Hz, 3A fuse. Installation: Install in accordance with regulatory requirements, such as the Domestic 24 16 Ventilation Compliance Guide (England & Wales) and the Residential Ventilation Association 45 34 recommendations. 51 44 60 62 70 81 80 111 97 184 100 201

*@FID (0 Pa). All units offer 100% variable speed control. Acoustic Data Performance curves for Eco version. dB(A) @ 3m Hemispherical dB(A) @ 3m Spherical % of Product Max flow Airflow Induct Inlet Induct Outlet Casing Breakout Casing Breakout 41% 44l/s @ 22Pa 27 38 27 24 HRV10 Q Plus Eco 69% 75l/s @ 51Pa 36 48 37 34 100% 108l/s @ 100Pa 43 57 51 48 41% 44l/s @ 22Pa 27 38 23 20 HRV10M Q Plus Eco 69% 75l/s @ 51Pa 36 48 33 30 100% 108l/s @ 100Pa 43 57 46 43 For full frequency acoustic data at various speeds please see www.titon.co.uk. All acoustic data is third party tested at Sound Research Laboratories (SRL) Ltd.

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 29 Features & Benefits

ÆÆ Extremely low Specific Fan Power; down to 0.39 W/l/s ÆÆ Highly efficient heat exchanger; up to 90%

3 Q Plus ÆÆ Airflow up to 161 l/s (581m /h) at 100 Pa ÆÆ Lightweight EPP construction giving high levels of thermal insulation ÆÆ Accepts 150mm diameter ducting ÆÆ Independent fan adjustment ÆÆ Intelligent frost protection, stepped reduction of supply air rates prevents HRV unit from For use in large dwellings freezing ÆÆ Setback facility to reduce ventilation where The HRV10.25 Q Plus continuously running whole-house local regulations allow ventilation unit with heat recovery has been specifically ÆÆ Fully adjustable boost overrun timer 0-60 designed to give improved performance over older minutes; can be used with non-latching

HRV10.25 HRV10.25 models, in line with new build design requirements. (momentary) switches to prevent unit from Combining extremely low power consumption and a highly being accidentally left in boost mode efficient heat exchanger specifically designed to enhance ÆÆ Intelligent controller, quick and easy to SAP performance via Appendix Q and can be incorporated commission into larger apartments or dwellings. ÆÆ EPP moulded 150mm low resistance The Eco versions offer a 100% airflow diverting Summer insulated port adaptors included as standard Bypass, recognised and listed in the UK Product Characteristics Database. They also include intelligent ÆÆ Lightweight for easy handling humidity options and can be fitted with the auralite® status ÆÆ Volt free switching control indicator (HMB and B models) or the auramode®, aurastat® or aura-tTM controllers (B models only). ÆÆ Pleated ISO Coarse 65% (G4) filters as standard ÆÆ Metal cased version available (HRV10.25M Q Plus) ÆÆ Quick fix mounting bracket ÆÆ On board aura-tTM capabilities ÆÆ Patented features ÆÆ Effective in reducing pollutants in the home and improving Indoor Air Quality (IAQ), therefore reducing the risk of Toxic Home Ultra energy efficient Heat Recovery Ventilation unit Recovery efficient Heat Ultra energy Syndrome

Eco Versions:

HRV 10.25 Q Plus ÆÆ Intelligent Summer Bypass & humidity controls ÆÆ SUMMERboost® facility

HRV 10.25M Q Plus Eco HMB Models: ÆÆ Compatible with auralite® (TP518) status indicator and aura-tTM controller

Eco B Models: Æ Eco-aura aurastat® auralite® Æ Compatible with range; ® TM auramode® auramode and aura-t controllers and aura-tTM auralite® (TP519) status indicator. aurastat® ÆÆ Duct heater control (requires independent power supply) ÆÆ Enthaply Heat Cell option available ÆÆ BMS compatible via RS485

30 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Product Codes Drawing & Dimensions HRV10.25 Q Plus B Eco-aura controls ready - TP482B - Energy Rating A~ TP482BC - Energy Rating A 920

HRV10.25 Q Plus 790 HRV10.25M Q Plus B Eco-aura controls ready - HRV10.25M Q Plus 800 TP483B - Energy Rating A Filters: XP44023/099 - ISO Coarse 65% (G4) bypass filter 400 set fitted as standard. XP46223/099 - ISO Coarse 65% (G4)/ISO ePM1 HRV10.25 Q Plus 663 55% (F7) filters available on request. HRV10.25M Q Plus 675 Standards

Conforms to requirements of UK statutory Building HRV10.25 Q Plus 484 Regulations and Technical Standards for Ventilation HRV10.25 M Q Plus 460 100 and BRE 398. SAP Appendix Q tested (https://www.ncm-pcdb.org.uk/sap/pcdbsearch. jsp?pid=34) Performance Exceeds requirements of Building Regulations Approved Document L (England & Wales). The figures and compliance levels below relate to current SAP requirements. Revised SAP guidance will have an effect on performance and up-to-date EU RoHS Directive compliant. figures can be found on the relevant product page at www.titon.co.uk. Conforms to requirements of EC council directives relating to Electromagnetic Compatibility and Specific fan Heat Exhaust terminal Fan speed power exchange efficiency Electrical Safety: configuration* setting (W/l/s) (%) 2006/95/EC (LVD), 2004/108/EC (EMC) Kitchen + 1 100% EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/ 0.41 90 A1:2004. additional wet room variable Kitchen + 2 100% 0.39 90 CE Marked. additional wet rooms variable Kitchen + 3 100% 0.43 88 Specification additional wet rooms variable Dimensions: HRV10.25 Q Plus - 790mm wide Kitchen + 4 100% 0.48 87 x 665mm high (excluding ports) x 485mm deep additional wet rooms variable (495mm with mounting bracket). HRV10.25M Q Kitchen + 5 100% 0.55 87 Plus 800mm wide x 675mm high (excluding ports) x additional wet rooms variable 460mm deep (470mm with mounting bracket) Kitchen + 6 100% 0.64 86 Weight: HRV10.25 Q Plus – 18kg, HRV10.25M Q additional wet rooms variable Plus – 31.5kg Kitchen + 7 100% 0.75 85 additional wet rooms variable Finish: HRV10.25 Q Plus – Black EPP, Figures taken from the BRE Test Results HRV10.25M Q Plus – White Paint *Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance requirements. Materials: Expanded polypropylene (EPP), Heat Exchanger – Polystyrene, Internal Insulation – Nominal fan performance Closed cell foamed, Nitrile rubber, class ‘O’ fire rating, Standard filters: Grade G4 pleated panel filters. NB: Except HRV10.25MQ Plus Housing – Zintec sheet steel, powder coated. 1 9 5 2 19 10 Guarantee period: 3 years (UK only) 3 30 19 4 38 31 230V ~ 50/60Hz, 5A fuse Electrical: 5 50 57 Installation: Install in accordance with 6 61 90 regulatory requirements, such as the Domestic 7 71 132 8 82 191 Ventilation Compliance Guide (England & Wales) 9 97 300 and the Residential Ventilation Association 10 100 320 recommendations.

*@FID (0 Pa). All units offer 100% variable speed control. Installation note: We recommend installing suitable sound attenuation with this product. Acoustic Data Performance curves for Eco version. dB(A) @ 3m Hemispherical dB(A) @ 3m Spherical Product % of Airflow Max flow Casing Induct Inlet Induct Outlet Breakout Casing Breakout 39% 56l/s @ 12Pa 32 47 35 32 HRV10.25 Q Plus Eco 66% 95l/s @ 44Pa 43 62 45 42 100% 144l/s @ 100Pa 48 70 54 51 39% 56l/s @ 12Pa 32 47 30 27 HRV10.25M Q Plus Eco 66% 95l/s @ 44Pa 43 62 39 36 100% 144l/s @ 100Pa 48 70 49 46 For full frequency acoustic data at various speeds please see www.titon.co.uk. All acoustic data is third party tested at Sound Research Laboratories (SRL) Ltd.

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 31 Features & Benefits

ÆÆ Highly efficient enthalpy counter flow heat exchanger ÆÆ Lightweight EPP construction giving high levels of thermal insulation ÆÆ Accepts 150mm or 125mm diameter ducting ÆÆ Independent fan adjustment ÆÆ Intelligent automated control of summer bypass, frost protection and humidity - Enthalpy functions ÆÆ Setback facility to reduce ventilation where local regulations allow For use in large dwellings ÆÆ Fully adjustable boost overrun timer 0-60 The HRV10.25 Q Plus continuously running whole-house minutes; can be used with non-latching ventilation unit with heat recovery has been specifically (momentary) switches to prevent unit from designed to give improved performance over older being accidentally left in boost mode models, in line with new build design requirements. ÆÆ Intelligent controller, quick and easy to Q Plus Combining extremely low power consumption and a highly commission efficient heat exchanger it can be incorporated into larger ÆÆ EPP moulded 150-125mm low resistance apartments or dwellings. insulated port adaptors included as standard The counter flow enthalpy heat exchanger has a selective ÆÆ Lightweight for easy handling polymer membrane film to achieve low air leakage levels ÆÆ Volt free switching control while providing moisture recovery from the exhaust air. These models are ideal for living areas with low humidity, ÆÆ Pleated ISO Coarse 65% (G4) filters as avoiding frost build up at low temperatures, they also have an standard antimicrobial membrane and long life cycle. ÆÆ Metal cased version available (HRV10.25M Q The Eco versions offer a 100% airflow diverting Summer Plus) Bypass. They also include intelligent humidity options and ÆÆ Quick fix mounting bracket can be fitted with auralite® status indicator or the auramode® ÆÆ Patented features and aurastat® controllers.

HRV10.25 HRV10.25 ÆÆ Effective in reducing pollutants in the home and improving Indoor Air Quality (IAQ), therefore reducing the risk of Toxic Home Syndrome

Eco BE Models: ÆÆ Compatible with Eco-aura range; aurastat® auramode® and aura-tTM controllers and auralite® (TP519) status indicator. ÆÆ Duct heater control (requires independent power supply) ÆÆ BMS compatible via RS485 Ultra energy efficient Heat Recovery Ventilation unit efficient Heat RecoveryUltra energy

auralite® auramode® aura-tTM aurastat®

Heat Water vapour Gases and contaminants Odours

32 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Product Codes Drawing & Dimensions HRV10.25 Q Plus B Eco Enthalpy Eco-aura controls ready - 920 TP482BE - Energy Rating A HRV10.25 Q Plus 790 Filters: HRV10.25M Q Plus 800 XP44023/099 - ISO Coarse 65% (G4) bypass filter set fitted as standard. XP46223/099 - ISO Coarse 65% (G4)/ISO ePM1 400 55% (F7) filters available on request.

Standards HRV10.25 Q Plus 663 HRV10.25M Q Plus 675 EU RoHS Directive compliant.

Conforms to requirements of EC council directives HRV10.25 Q Plus 484 relating to Electromagnetic Compatibility and HRV10.25 M Q Plus 460 100 Electrical Safety: 2006/95/EC (LVD), 2004/108/EC (EMC) EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/ A1:2004. CE Marked. Specification Heat Cell Technical Data Features & Benefits Dimensions: HRV10.25 Q Plus - 790mm wide 3 (Typical conditions at 140m /h) Æ x 665mm high (excluding ports) x 485mm deep Æ No transfer of gases or pollutants ÆÆ Heat change rate 80 % - only heat and steam are (495mm with mounting bracket). transferred by the membrane ÆÆ Degree of moisture change 70 % Weight: HRV10.25 Q Plus – 21.5kg, ÆÆ Long life cycle - permanent ÆÆ Leakage at 100 Pa < 1 % transmission parameters Finish: HRV10.25 Q Plus – Black EPP. ÆÆ Temperature stability - 25°C ÆÆ Minimum leakage up to 65°C Materials: Expanded polypropylene (EPP), Heat ÆÆ Optimum flow behaviour, low Exchanger – Selective polymer membrane film. pressure loss Internal Insulation – Closed cell foamed, Nitrile Æ Frost- and heat-proof rubber, class ‘O’ fire rating, Standard filters: Grade Æ ISO Coarse 60% (G4) pleated panel filters. NB: ÆÆ High, sensitive and latent transmission rate Guarantee period: 3 years (UK only) ÆÆ Antimicrobial (Microban® - Electrical: 230V ~ 50/60Hz, 5A fuse integrated hygiene protection) ÆÆ Can be cleaned using water Installation: Install in accordance with regulatory requirements, such as the Domestic ÆÆ European manufactured heat cell Ventilation Compliance Guide (England & Wales) and the Residential Ventilation Association recommendations. Nominal fan performance

1200 9% 7W

22% 15W 1000 37% 32W

52% 66W 800 65% 114W

82% 200W 600 100% 331W Pressure (Pa) 400

200

0 0 50 100 150 200 l/s 0 100 200 300 400 500 600 700 m3/h Volume Flow Acoustic Data

dB(A) @ 3m Hemispherical dB(A) @ 3m Spherical Product Airflow Induct Inlet Induct Outlet Casing Breakout Casing Breakout 56l/s @ 12Pa 32 47 35 32 HRV10.25 Q Plus Eco 95l/s @ 44Pa 43 62 45 42 144l/s @ 100Pa 48 70 54 51 56l/s @ 12Pa 32 47 30 27 HRV10.25M Q Plus Eco 95l/s @ 44Pa 43 62 39 36 144l/s @ 100Pa 48 70 49 46

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 33 Features & Benefits

ÆÆ Highly versatile compact unit ÆÆ Extremely low Specific Fan Power of 0.43 W/l/s ÆÆ Highly efficient heat exchanger; up to 89% ÆÆ Airflow up to 194 l/s (700m3/h) at 100 Pa ÆÆ Accepts 200mm diameter ducting ÆÆ Intelligent frost protection, stepped reduction of supply are rates prevents HRV unit from freezing ÆÆ G4 filters as standard, F7 as an option For use in large dwellings ÆÆ Fully adjustable boost overrun timer 0-60

HRV20 Q Plus HRV20 minuets; can be used with non-latching The new HRV20 Q Plus continuously running (momentary) to prevent unit from whole-house ventilation unit with heat recovery has been being accidently left in boost mode specifically designed to expand Titon’s current HRV ÆÆ Volt free switching control range by offering airlfows of up to 194 l/s (700 m3/h). ÆÆ Intelligent controller, quick and easy to Combining extremely low power consumption and a highly commission efficient heat exchanger specifically designed to enhance SAP performance via Appendix Q and can be incorporated ÆÆ On board aura-tTM capabilities into larger apartments or dwellings. ÆÆ Quick fix mounting bracket Offering a 100% airflow diverting Summer Bypass, ÆÆ Patented recognised and listed in the UK Product Characteristics Database. They also include intelligent humidity options and ÆÆ Independent fan adjustment ® TM can be fitted with the auralite status indicator and aura-t ÆÆ Effective in reducing pollutants in the home controller (HMB and B models) or the auramode® or aurastat® and improving Indoor Air Quality (IAQ), controllers (B models only). therefore reducing the risk of Toxic Home Syndrome

Eco B Models: Intelligent Summer Bypass & humidity controls ÆÆ SUMMERboost® facility ÆÆ Compatible with Eco-aura range; aurastat®, auramode® and aura-tTM controllers and auralite® (TP519) status indicator Ultra energy efficient Heat Recovery Ventilation unit Recovery efficient Heat Ultra energy

auralite® auramode® aura-tTM aurastat®

34 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Product Codes Drawing & Dimensions HRV20 Q Plus B Eco-aura controls ready - TP651B/LH (left hand config) or 1149 TP651B/RH (right hand config) Energy Rating A .

. 752 Filters:

XP2010561 - ISO Coarse 65% (G4) bypass filter set . 300 fitted as standard.

ISO Coarse 65% (G4)/ISO ePM1 75% XP2010929 - (F7) available on request.

. 708 Standards

Conforms to requirements of UK statutory Building . 100 Regulations and Technical Standards for Ventilation

and BRE 398 . 533 Uninstalled SAP Appendix Q tested (https://www.ncm-pcdb.org. 549 Installed uk/sap/pcdbsearch.jsp?pid=34) Exceeds requirements of Building Regulations Approved Document L (England & Wales) Performance EU RoHS Directive compliant. The figures and compliance levels below relate to current SAP requirements. Revised SAP guidance will have an effect on performance and up-to-date Conforms to requirements of EC council directives figures can be found on the relevant product page at www.titon.co.uk. relating to Electromagnetic Compatibility and Electrical Safety: Specific fan Heat 2006/95/EC (LVD), 2004/108/EC (EMC) EN 60335- Exhaust terminal Fan speed configuration* setting power exchange efficiency 1:2002/A2:2006, EN 60335-2- 80:2003/A1:2004. (W/l/s) (%) Kitchen + 1 100% CE Marked. 0.49 89 additional wet room variable Kitchen + 2 100% Specification 0.43 88 additional wet rooms variable Dimensions: HRV20 Q Plus - 752mm wide x Kitchen + 3 100% 0.44 88 708mm high (excluding ports) x 534mm deep additional wet rooms variable (549mm with mounting bracket). Kitchen + 4 100% 0.48 87 Weight: 46kg. additional wet rooms variable Kitchen + 5 100% 0.53 86 Finish: White Paint. additional wet rooms variable Kitchen + 6 100% Materials: Zintec sheet steel, powder coated. 0.60 86 additional wet rooms variable Guarantee period: 3 years (UK only). Kitchen + 7 100% 0.70 85 additional wet rooms variable Electrical: 230V ~ 50/60Hz, 5A fuse. Installation: Install in accordance with Figures taken from the BRE Test Results regulatory requirements, such as the Domestic *Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance Ventilation Compliance Guide (England & Wales) requirements. and the Residential Ventilation Association recommendations. Nominal fan performance Maintenance: Service and filter clean/replacement subject to local environment - see product manual. 800 Nominal Speeds % Watts* 700 1 18 7 2 30 15 600 3 41 31 4 53 62 500 5 65 111 6 77 185 400 7 88 283 300 8 100 326 Boost speeds 100% variable 200

100

0 0 50 100 150 200 250 l/s 0 200 400 600 800 m3/h

*@FID (0 Pa). All units offer 100% variable speed control. Acoustic Data dB(A) @ 3m Hemispherical dB(A) @ 3m Spherical % of Product Max flow Airflow Induct Inlet Induct Outlet Casing Breakout Casing Breakout 41% 72l/s @ 18Pa 33 43 27 24

HRV20 Q Plus Eco 65% 127l/s @ 51Pa 46 58 42 39

100% 189l/s @ 100Pa 57 70 49 46

For full frequency acoustic data at various speeds please see www.titon.co.uk. All acoustic data is third party tested at Sound Research Laboratories (SRL) Ltd.

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 35 Features & Benefits

ÆÆ Low profile ÆÆ Extremely low SFP; down to 0.55 W/l/s ÆÆ Highly efficient heat exchanger; up to 83% ÆÆ Airflow up to 83 l/s (300m3/h) at 100 Pa ÆÆ Intelligent controller, quick and easy to commission ÆÆ Fully adjustable boost overrun timer 0-60 minutes; use with nonlatching (momentary) switches to prevent unit from being accidentally left in boost mode H200 Q Plus ÆÆ Accepts either 204mm x 60mm rectangular For use in a wide ducting, 150mm or 160mm diameter ducting, range of dwellings no adaptors required ÆÆ Intelligent frost protection, stepped reduction The H200 Q Plus continuously running horizontal of supply air rates prevents HRV unit from whole-house ventilation unit with heat recovery is freezing independently tested by the BRE. It is ideal for flats due to its low profile. ÆÆ Setback facility to reduce ventilation where local regulations allow Combining low power consumption and a highly efficient heat exchanger, this unit enhances SAP performance via ÆÆ Volt free switching control Appendix Q and remains versatile enough in size to be ÆÆ ISO Coarse 65% (G4) filters as standard, ISO equally functional in large through to small apartments alike. ePM1 55% (F7) as an option The H200 Q Plus comes in Eco versions only with a 100% ÆÆ Pleated cardboard frame filters airflow diverting Summer Bypass, recognised and listed in ÆÆ Independent fan adjustment the UK Product Characteristics Database. They also include intelligent humidity options and can be fitted with the auralite® ÆÆ Effective in reducing pollutants in the home status indicator (HMB and B models) or the auramode®, and improving Indoor Air Quality (IAQ), aurastat® or aura-tTM controllers (B models only). therefore reducing the risk of Toxic Home Syndrome

Eco Versions: ÆÆ Intelligent Summer Bypass & humidity controls

ÆÆ SUMMERboost® facility ÆÆ Compatible with Eco-aura range; aurastat® Ultra energy efficient Heat Recovery Ventilation unit Recovery efficient Heat Ultra energy auramode® and aura-tTM controllers and auralite® (TP519) status indicator. ÆÆ Duct heater control (requires independent power supply) ÆÆ BMS compatible via RS485

auralite® auramode® aura-tTM aurastat®

36 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Product Codes Drawing & Dimensions H200 Q Plus B Eco-aura controls ready 204x60 - TP461B - Energy Rating A

600 H200 Q Plus B Eco-aura controls ready Ø160 -

TP463B - Energy Rating A 1000

400 200 H200 Q Plus B Eco-aura controls ready Ø150 - 100

TP462B - Energy Rating A 0 250 50 100 Filters: XP2010173 – ISO Coarse 65% (G4) filter set fitted

as standard. 205 XP46223/099 - ISO ePM1 55% (F7) filters available 250 on request.

Standards 5

Conforms to requirements of UK statutory Building 45 Void Regulations and Technical Standards for Ventilation vice and BRE 398. Ser SAP Appendix Q tested (https://www.ncm-pcdb.org.uk/sap/pcdbsearch. Performance jsp?pid=34) The figures and compliance levels below relate to current SAP requirements. Exceeds requirements of Building Regulations Revised SAP guidance will have an effect on performance and up-to-date Approved Document L (England & Wales). figures can be found on the relevant product page at www.titon.co.uk. EU RoHS Directive compliant. Exhaust terminal Fan speed Specific fan Heat Conforms to requirements of EC council directives configuration* setting power exchange efficiency relating to Electromagnetic Compatibility and (W/l/s) (%) Electrical Safety: Kitchen + 1 100% 0.58 83 2006/95/EC (LVD), 2004/108/EC (EMC) additional wet room variable EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/ Kitchen + 2 100% 0.55 83 A1:2004. additional wet rooms variable CE Marked. Kitchen + 3 100% 0.61 82 Specification additional wet rooms variable Kitchen + 4 100% Dimensions: 1000mm wide (excluding ports) x 0.72 81 200mm high x 600mm deep additional wet rooms variable Kitchen + 5 100% 0.85 80 Weight: 32kg additional wet rooms variable Finish: White Paint Kitchen + 6 100% 0.99 80 additional wet rooms variable Materials: Housing: Zintec sheet steel housing, Kitchen + 7 100% powder coated white 1.20 80 Internal insulation: Closed cell foamed Nitrile additional wet rooms variable rubber, class ‘O’ fire rating Figures taken from the BRE Test Results Heat exchanger: aluminium *Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance Standard filters: Grade ISO Coarse 60% (G4) requirements. pleated panel filters Guarantee period: 3 years (UK only) Nominal fan performance Electrical: 230V ~ 50/60Hz, 3A fuse 500 Install in accordance with Installation: 450 regulatory requirements, such as the Domestic 1 15 8 400 Ventilation Compliance Guide (England & Wales) 2 27 11 and the Residential Ventilation Association 350 3 40 19 recommendations. 300 4 52 34 5 65 58 Maintenance: Service and filter clean/replacement 250 subject to local environment – see product manual. 6 79 87 200 7 90 126 150 8 100 162

100 50

0 0 10 20 30 40 50 60 70 80 90 100 l/s 40 80 120 160 200 240 280 320 360 m 3/h *@FID (0 Pa) Performance curves for Eco version.

Acoustic Data

dB(A) @ 3m Hemispherical dB(A) @ 3m Spherical Product % of Airflow Max flow Casing Induct Inlet Induct Outlet Breakout Casing Breakout 47% 39l/s @ 20Pa 25 37 25 22

H200 64% 53l/s @ 37Pa 30 21 31 28

100% 83l/s @ 100Pa 39 54 41 38

For full frequency acoustic data at various speeds please see www.titon.co.uk. All acoustic data is third party tested at Sound Research Laboratories (SRL) Ltd.

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 37 Features & Benefits

ÆÆ Easy to maintain ÆÆ Low noise and vibration levels due to expanded polypropylene housing ÆÆ Low profile wall mounted fascia ÆÆ No additional ductwork required ÆÆ ‘Sleep mode’ function. By putting the unit to sleep, fans can be configured to either stop (default) or slow to humidity protection level for a period of time (default 1 hour) after which they will return to the previous setting. For use in residential dwellings ÆÆ ‘Intensive speed’ (Manual) to quickly remove The SR700 from Titon is a decentralised ventilation unit any odours that are present. with heat recovery providing continuous airflow to your ÆÆ ‘Intensive speed’ (Automatic) to quickly home. It extracts stale, moist and contaminated air and replaces it with warmed fresh air from outside, improving remove excessive amounts of poor air, indoor air quality and keeping heating costs down. moisture and dangerous levels of Carbon Dioxide from within the home. (Sensors The system is easily installed and maintained, ideal for required). removing internal condensation and eliminating mould ÆÆ ‘Cross ventilation’ for a constant flow growth within the home. Unlike regular extractor fans that of fresh air through the house (No heat waste 100% of heat that passes through them, the SR700 recovery) system will recover up to 94%* of wasted heat and create a comfortable living environment. ÆÆ Wall thickness: Min. 305mm - Max. 700mm+ ÆÆ Achieves 20Pa back pressure as per BS EN 13141-8:2014 Easy to install, duct free ventilation solution Easy to install, duct free SR700 - Single Room Heat Recovery Unit

*In house tested

Aesthetically pleasing design, offering efficient airflow and heat recovery during the winter and fresh air during the summer.

38 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Drawing & Dimensions 711 34.5 Ø220.4 700 Ø180 Product Codes Performance and Acoustic Data SR700 - TP600 dB(A) SRC1 (Control unit) - TP590 Airflow SFP (W/l/s) Product Fan Speed max @ 3m Setting (m³h) @0 pa Replacement G2 filter -XP2010838 Hemispherical Replacement insect filter -XP2010320 Fan Setting 1 (Large Dwelling) *Sleep Mode 6.5 or off 8/0 0.62 Relative humidity (RH) sensor (surface mount) - TP610 *Off Relative humidity (RH) sensor (flush mount) -TP614 Humidity protection 6.5 8 0.62 Carbon dioxide (CO ) sensor (surface mount) - TP611 2 Reduced 20 19 0.27 Carbon dioxide (CO2) sensor (flush mount) -TP615 Combined relative humidity(RH) and Nominal 40 32 0.22 Intensive 60 39 0.24 Carbon dioxide (CO2) sensor (surface mount) - TP612 SR700 Combined relative humidity(RH) and Fan Setting 2 (Small Dwelling) *Sleep Mode 6.5 or off 8/0 0.62 Carbon dioxide (CO2) sensor (flush mount) -TP616 Volatile organic compound (VOC)/ *Off Air quality sensor (surface mount) - TP613 Humidity protection 6.5 8 0.64 Volatile organic compound (VOC)/Air quality sensor Reduced 10 11 0.44 (flush mount) -TP617 Nominal 17 18 0.3 Intensive 25 24 0.24 Standards *Configurable option SR700 System is tested to the following standards: Airborne sound insulation. Rating according to: BS EN ISO 717-1:2013 & BS EN ISO 10140-2:2010

BS EN 13141-8:2014 (Ventilation for buildings) Status Dn,e,w (c;ctr) EN 55014-1:2006 inc A1:2009 & A2:2011 Unit Open 34dB EN 55014-2:2015 category IV Unit Closed 51dB EN 61000-3-2:2014 EN 61000-3-3:2013 (Electromagnetic compatibility [EMC]) SRC1 Controller BS EN ISO 717-1:2013 A system consists of a central control unit which manages between 1 and 3 off pairs BS EN ISO 10140-2:2010 of through the wall 12V (dc) bidirectional fan units which are typically fitted in pairs BS EN ISO 3741:2010 (Acoustics) so that they can provide cross flow ventilation within the home. IEC 60335-2-80:2002 +A1:2004, +A2:2008 in conjunction with IEC 60335-1:2010 A controlled ventilation system such as the SR700 from Titon meets the criteria for low BS EN 60335-2-80:2003 +A1:2004, +A2:2009 in energy housing and is ideal for installing during refurbishment of a home. conjunction with EN 60335-1:2012/AC:2014 +A11:2014 BS EN 62233 (Electrical Safety)

Specification Dimensions: 711 long x Ø180 inside wall & Ø220mm x 35mm internal fascia

Weight: SR700 - 3Kg, SRC1 controller - 94g SRC1 (Control unit) - Materials: TP590 Tube: Expanded polypropylene (EPP) Sensors Components: White ABS plastic Heat exchanger: Ceramic Filters: Synthetic Internal insulation: Closed cell foamed nitrile Fascia plate: White perspex Guarantee period: 2 years Electrical: 230V ~ 50/60Hz, 3A fuse Installation: The Titon SRHRV Fan unit is Flush mount Surface mount designed to be mounted through a wall with a thickness between 305mm & 700mm. Flush Surface Sensor Description Maintenance: Easy to maintain. Routine service Mount mount and filter clean/ replacement are all that are Relative humidity (RH) Sensor TP614 TP610 normally required to keep the SRHRV System Carbon dioxide (CO ) Sensor TP615 TP611 working efficiently. Subject to local environment - 2 Combined relative humidity(RH) and Carbon Dioxide (CO ) Sensor TP616 TP612 see product manual. 2 Volatile organic compound (VOC)/Air quality Sensor TP617 TP613

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 39

® Features & Benefits

ÆÆ Effective in reducing pollutants in the home, improving Indoor Air Quality (IAQ) and reducing the risk of Toxic Home Syndrome

Filter ÆÆ Low pressure drop 2 ÆÆ Low cost ÆÆ Optional ISO ePM1 55% (F7) filter can be installed to further improve indoor air quality

HRV Accessories HRV ÆÆ Compact design ÆÆ Compatible with Titon’s range of MVHR units Offering extra protection against ÆÆ Fully lined box to reduce duct bound noise and condensation external NO2 pollutants Æ ® Æ The unit can be installed in both intake air The Titon Trimbox NO2 Filter reduces Nitrogen Dioxide and supply ducting (NO2) which is predominately produced by exhaust gases

from diesel engines. ÆÆ 98% NO2 reduction at pre filter Due to this pollution arising in cities and urban areas there is concentrations of ≈ 200μg m3 a need to implement mitigation measures to improve the Æ ® Æ Effective silencer

Trimbox NO Trimbox indoor air quality (IAQ). The Trimbox NO2 Filter is an effective means of reducing high NO2 to an acceptable mean ÆÆ Third party tested for both NO2 and Acoustic 3 annual concentration level of 40μg/m . reductions

In addition to outstanding NO2 reductions, the Titon Trimbox ÆÆ ISO Coarse 60% (G4) filter reduces 100% of active carbon filters also absorb sulphur dioxide, hydrogen PM /35% of PM particles sulphide, hydrogen chloride, ammonia odours, volatile 10 2.5 organic compounds and solvents. ÆÆ ISO ePM1 55% (F7) filter reduces up to 95%

of PM2.5 particles

Acoustic Data Independently tested at SRL, report reference C/23276/ TO5 to BS EN ISO 7235:2009

Octave Band (Hz) Description Static Insertion Loss, dB

63 125 250 500 1000 2000 4000 8000

Unit One 6.5 7.6 4.9 8.6 16.1 26.8 32.9 36 (3 filters) Unit Two 6.1 6.8 5.6 10 18.5 35.3 35 39.8 (4 filters)

Nitrogen dioxide filtration and unit pressure drop (Based on nitrogen dioxide pre filter concentrations of ≈ 200μg m3)

Airflow rate Filter pressure Concentration (l/S) drop (Pa) reduction (%)

Unit One (3 filters)

29 31 97.6

80.3 134 97.9

Unit Two (4 filters)

45.3 50 98.1

80.6 106 97.5

40 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Standards Resistance - Trimbox NO2 Filter ISO Coarse 60% (G4) Prefilter, Unit One Third party tested for both NO2 and acoustic reductions based around the standards currently in place for health 160 as specified by the World Health Organisation and the European Union. 140 120 Testing references: 100

COSHH - Workplace exposure limits e (Pa) COMEAP - Government guidance regarding health of air 80

pollution essu r 60 P r WHO - World Health Organisation 40 20 Specification 0 Dimensions: 350mm wide x 690mm high (excluding ports) 0 10 20 30 40 50 60 70 80 x 205mm deep Airflow (l/s) Port Dimension: 220mm x 90mm, Ø150mm, Ø160mm Weight:

Unit One (3 Filters) - 17 Kg Resistance - Trimbox NO2 Filter Unit Two (4 Filters) - 20 Kg ISO Coarse 60% (G4) Prefilter, Unit Tw o Insulation Jacket - 2.8 Kg 180 Finish: White Paint 160 Materials: 140 Housing: Zintec sheet steel housing, powder coated white 120 Internals: Zintec sheet steel e (Pa) 100 Pre-Filter: Grade ISO Coarse 60% (G4) synthetic filters as 80 standard, ISO ePM1 55% (F7) optional essu r

P r 60 Active Carbon Filter: Honeycomb matrix constructed filter 40 filled with granular active carbon 20 Internal insulation: Closed cell foamed nitrile rubber, class 0 0 20 40 60 80 100 120 ‘O’ fire rating Airflow (l/s) Duct Ports: Plastic Installation: Install in accordance with regulatory requirements, such as the Domestic Ventilation Compliance Resistance - Trimbox NO2 Filter Guide (England & Wales) and the Residential Ventilation ISO ePM1 55% (F7) Prefilter, Unit One Association recommendations These units can be installed either vertically or horizontally 160 140 Maintenance: Service and filter cleaning/replacement 120 subject to local environment – see product manual 100 e (Pa) Accessories: Replacement pre-filters and active carbon 80 filters

essu r 60

Product Codes P r 40 UNIT ONE: 20 TP552 Ø160, TP554 Ø150 0 UNIT TWO: 0 14 28 42 56 69 83 TP553 Ø160, TP555 Ø150 Airflow (l/s) Removable insulation jacket: 220x90mm ports - XP9910248 150 or 160mm ports - XP9910305 Resistance - Trimbox NO2 Filter ISO ePM1 55% (F7) pre filter (ISO Coarse 60% (G4) standard ISO ePM1 55% (F7) Prefilter, Unit Two in units) - XP2010121

Behind unit duct mounting kit - TP558 220 200 180 350 400 160 140 e (Pa) 120 100 essu r 80 P r 60 40 20 0 0 14 28 42 56 69 83 97 Airflow (l/s) 690

205

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 41

® Features & Benefits

ÆÆ Low pressure drop ÆÆ Low cost ÆÆ Both ISO Coarse 60% (G4) and ISO ePM1 55% (F7) pleated filter options ÆÆ Compact design ÆÆ Compatible with Titon’s range of MVHR units ÆÆ Fully lined version reduces the risk of duct HRV Accessories HRV bound noise and condensation ÆÆ The unit can be installed in both intake air Offering extra protection against and supply ducting external pollutants ÆÆ ISO Coarse 60% (G4) filter reduces 100% of Trimbox Filter Trimbox PM10/35% of PM2.5 particles Titon’s new Trimbox Filter - Lined (insulated) and Æ Unlined Units reduces outdoor air pollutants as part of Æ ISO ePM1 55% (F7) filter reduces up to 95% your building ventilation system. of PM2.5 particles With pollution an ever increasing problem, the Trimbox Filter® allows for extra protection within the home. By adding a Trimbox Filter® to the ventilation system, it allows increased Finish: White Paint/Zintec Finish. protection from external contaminants. Ideal for new build or refurbishment, the Trimbox Filter® creates a safer Materials: environment for any dwelling. Housing: Zintec sheet steel housing, powder coated white. Filters: Grade ISO Coarse 60% (G4) synthetic filters as standard/ISO ePM1 55% (F7) wet-laid glass fibre paper. Lined - Unit Internal insulation: Closed cell foamed nitrile rubber, (insulated) class ‘O’ fire rating. Installation: Install in accordance with regulatory requirements, such as the Domestic Ventilation Compliance Guide (England & Wales) and the Residential Ventilation Association recommendations. These units can be installed both vertically and horizontally.

Unlined - Unit Maintenance: Service and filter cleaning/replacement subject to local environment – see Product Manual. (uninsulated)

Accessories: Replacement filters: Standards ISO Coarse 60% (G4) Filter – XP2010021 Conforms to the European standard for air filters ISO ePM1 55% (F7) Filter – XP2010121 (EN779:2012)

Product Codes Specification Lined Version Lined Version TP560 - 204x60, TP561 - 220x90, TP562 - Ø125, Dimensions: 355mm wide x 203mm high (excluding ports) x TP563 - Ø150, TP564 - Ø160 206mm deep. Unlined Version Unlined Version TP565 - 204 x 60, TP566 - 220 x 90, TP567 - Ø125, Dimensions: 338mm wide x 208mm high (excluding ports) x TP568 - Ø150, TP569 - Ø160 200mm deep. Lined & Unlined Versions Port Dimension: 204mm x 60mm, 220mm x 90mm, Ø125mm, Ø150mm, Ø160mm. Weight: 4 Kg.

42 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Resistance – Filter Box – ISO Coarse 60% (G4) filter

100 90 80 70 60 50 40 Pressure (Pa) 30 20 10 0 0 10 20 30 40 50 60 70 80 90 Airflow (l/s)

Resistance – Filter Box – ISO ePM1 55% (F7) filter

200 180 160 140 120 100 80 Pressure (Pa) 60 40 20 0 0 10 20 30 40 50 60 70 80 90 Airflow (l/s)

Drawing and Dimensions

205 400

200

Service Void 350

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 43 Product Codes

Model Part Condensate Number Drain Cover

HRV1.25, 1.35 TP545

HRV1.6 TP544

HRV1.75, 2, 2.85, 3 TP546

HRV10M, 10.25M TP547 HRV Accessories HRV

For use with Titon HRV units HRV Condensate Drain Covers are designed to conceal the service pipe attached to the underside of Titon HRV units to improve overall appearance. The covers match the construction, quality and finish of the HRV units and can be easily installed and removed if required. The cover has a depth of 74mm and the drainage pipe must be installed within this depth for the cover to be fitted. The drainage trap cannot be installed within this cover void, therefore it must be located in a suitable alternative position. HRV Condensate Drain Cover HRV

74mm

TP544, TP545 & TP546 TP547

44 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Product Codes

Part Part Model Number Number Ducting Cover Straight Flared

HRV1.25, 1.35 TP585 TP577

HRV1.6 TP589 TP588

HRV1.75, 2, 2.85, 3 TP586 TP578

HRV10M, 10.25M TP587 TP579 HRV Accessories HRV

For use with Titon HRV units HRV Duct Covers are designed to conceal the ducting/ silencers from the ports at the top of the unit to the ceiling of the property. The ducting cover also helps HRV Duct Cover HRV reduce ducting breakout noise levels into the room. This both improves the overall appearance of the installation and the noise levels. The covers match the high quality construction and finish of the HRV units and can be easily installed. Access to the control box and ducting can be achieved easily by the removal of the front panel of the ducting covers. The covers have an adjustable height of 300mm to 400mm so that variations in height of the unit to the ceiling can be accommodated. The covers are suitable for use with rigid or flexible ducting options, and also Titon’s semi-rigid duct attenuators. There are two types of design of covers, one that is flush with the profile of the units leaving a small area at the ceiling for the ducting to pass through and the other opens up at the ceiling so that round to rectangular elbows can be used.

Straight

m

m

0

0

4

o

t

m

m

0

0 3

Flared

m

m

0

0

4

o

t

m

m

0

0 3

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 45 Product Codes Small First Fix Solution (Ø150 to Ø150) HRV1.75, 2, 2.85 and 3 Q Plus - TP575 HRV 1.6 Q Plus - TP576 Large First Fix Solution (Ø150 to 220x90) HRV1.75, 2, 2.85 and 3 Q Plus – TP591 HRV 1.6 Q Plus - TP592 The large first fix solution is the same width as the unit, but greater in depth which allows the use of Ø150 round to rectangular 220x90 elbows and therefore can be fitted in a lower ceiling void. The 90° elbows are not sold as part of the kit and should be purchased from

HRV Accessories HRV Titon separately.

For use with Titon HRV units HRV First Fix Solutions are designed to make installation of the ducting from the ceiling void to the unit easier and give a high quality finish. This will reduce the installation time and complete the overall appearance of the installation. The First Fix Solutions match the construction, quality and finish of the HRV units and can be easily installed into the property. The first fix solutions are designed to be used in conjunction with Titon’s 90° elbows with either the Ø150 round to round ports or the Ø150 round to rectangular 220x90 ports.

HRV First Fix Solutions Fix First HRV There are two first fix solutions (small & large) which can be used with Titon’s HRV 1.6 – 3 units. The small first fix solution is designed to have the same face area as the top of the unit so that the ducting from the unit travels directly to the ports in the first fix. This solution requires the use of Ø150 round to round elbows in the ceiling void due to the closeness of the ports.

670 652 = = 9

5

9

= = 5

=

=

0

8

2

3

4

3

=

=

Ø150 Ø150

TP575 - HRV 1.75-10.25 Small First Fix TP591 - HRV 1.75-10.25 Large First Fix

545 433

9

9 = = = = 5

5

=

=

9

3

9

7

3

2

=

=

Ø125 Ø125

TP576 - HRV 1.6 Small First Fix TP592 - HRV 1.6 Large First Fix

46 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Product Codes

Model Part AV Mounting Kit Number

HRV1.25, 1.35 TP570

HRV1.6, 1.75, 2, 2.85, 3 TP571

HRV10, 10.25 TP572

HRV10M, 10.25M TP573 HRV Accessories HRV

For use with Titon HRV units HRV Anti-Vibration (AV) units have been specifically designed to isolate the unit from the wall to further reduce any low levels of vibration induced noise from being transmitted to the mounting structure. The AV mounting brackets match the construction, quality and finish of the HRV units in addition to the standard fixings supplied without obstructing any subsequently attached ducting. The use of 4 rubber AV bobbins per mounting kit have been specifically selected to give the best performance whilst the

HRV AV Mounting Kits AV HRV bracket design keeps the unit close to the mounting surface. This means the AV mounting kits can be retrofitted to existing unit installations using the existing fixing points. Please note: AV brackets cannot be retro fitted on units with the double flap hinged wiring cover.

Front Back

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 47 Features & Benefits

ÆÆ Built in temperature control

ÆÆ Aluzinc casing

ÆÆ Stainless steel heating elements

ÆÆ Rolled rubber seals for duct connection

ÆÆ Two stage overheat protection

ÆÆ Built in temperature control HRV Accessories HRV ÆÆ Manual reset button when temperature

Duct Heater reaches 100°C For use with Titon HRV units ÆÆ Compatible with Titon’s cold climate HRV units Æ Titon’s Duct Heaters are designed to heat clean air in Æ IP44 Rating conjunction with Titon’s HRV cold climate ventilation units. Duct Heaters uses include tempering fresh air in ventilation All Duct Heaters have two-stage overheat protection: systems, supplying heated air to rooms and boosting supply 1. the first stage switches on when the temperature air temperature in heat recovery units - including Titon’s reaches 50°C (resets automatically). Passivhaus approved MVHR unit. 2. the second stage switches on when the temperature Casings are made from aluzinc coated steel, which is ideal reaches 100°C (is reset manually with push button for high temperature. Heating elements tubing is made from on the casing). stainless steel AISI 304. Heaters can be installed vertically or horizontally. All Duct Heaters are installed with 2 protection thermostats, Maximum output air temperature 50°C. screw terminals for easy connection and rubbers seals to fit to ducting.

Temperature Sensor

Temperature control

48 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Product Codes Specification EKA-NV125-0.9 – Ø125mm 0.9kW electric duct heater with Dimensions: 370mm length, diameter plus 32mm height. temperature control, including remote duct temperature sensor Material: Aluzinc casing EKA-NV125-1.5 – Ø125mm 1.5kW electric duct heater with temperature control, including remote duct temperature sensor Guarantee period: 2 years EKA-NV150-1.5 – Ø160mm 1.5kW electric duct heater with Electrical: 230V ~ 50/60Hz temperature control, including remote duct temperature sensor Installation: Install in accordance with regulatory requirements, EKA-NV160-1.2 – Ø160mm 1.2kW electric duct heater with such as the Domestic Ventilation Compliance Guide (England & temperature control, including remote duct temperature sensor Wales) and the Residential Ventilation Association recommendations. EKA-NV160-1.5 – Ø160mm 1.5kW electric duct heater with Please refer to our cold temperature MVHR product manual for further temperature control, including remote duct temperature sensor guidance on installation.

Drawing & Dimensions

32

Dimensions in mm

Performance Details

200

180 EKA 125 1.5kW

160

140

a) 120 EKA 125 0.9kW

100

Pressure ( P 80

60 EKA 160 1.2kW EKA 150/160 1.5kW 40

20

0 0 100 200 300 400 500 600 Volume Flow (m3/h)

Min. Min. Product Voltage Power Diameter airflow airflow Type (50 Hz) kW (m3/h) (l/s)

EKA-NV125-0.9 125 70 19 1~230 0.9

EKA-NV125-1.5 125 70 19 1~230 1.5

EKA-NV150-1.5 160 110 30 1~230 1.5

EKA-NV160-1.2 160 110 30 1~230 1.2

EKA-NV160-1.5 160 110 30 1~230 1.5

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 49 Features & Benefits

ÆÆ High energy efficiency levels, via Electronically Commutated (EC) motor ÆÆ Very low power consumption/specific fan power ÆÆ Airflow up to 120 l/s (430m3/h) at 100 Pa ÆÆ Compact – unit is small and low in profile, can be fitted in airing cupboards, cupboards or loft spaces ÆÆ Easy installation due to innovative sub- assembly and unique packaging design ÆÆ Optional two part installation CME3 Q Plus For use in dwellings with six wet ÆÆ Performs to high levels through rectangular rooms or fewer ports; does away with need for round to rectangular adaptors, saving cost, reducing The new CME3 Q Plus is ideal for continuous extract of joints and installation time stale, damp and polluted air to the outside environment. ÆÆ Optional adjustable humidity sensor The CME3 Q Plus is the latest addition to the centralised (between 55% RH & 85% RH) triggers boost mechanical extract unit range. The combination of aesthetic smooth lines, unique tilted impeller and single level ports speed

Continuous Mechanical Extract provides the ideal solution for hidden ceiling installation in ÆÆ Duct ports on one level, lessening need for flats and apartments. unnecessary bends in ducting, saving cost, reducing joints and installation time The unit has a very large duty range over 120 l/s (400m3/hr) at reasonable static pressure. ÆÆ Ideal for central mechanical ventilation in refurbishment of single floor dwellings where there is only space for rectangular ducting ÆÆ Low unit noise ÆÆ Fully adjustable boost overrun timer 0-30 minutes ÆÆ Can accept either 204mm x 60mm or 110mm x 54mm ducting ÆÆ Unit can be cleaned and serviced without disturbing ducting ÆÆ Original enclosure design with 100mm spgots on one level, ideal for low profile ceiling mounting ÆÆ For use in conjunction with Titon trickle vents ÆÆ Available in volt free and switch live inputs ÆÆ Hidden fixings ÆÆ Quick and easy commissioning ÆÆ Demand control ventilation ready ÆÆ Wide duty range For use with Titon Trickle Ventilators - see page 96. ÆÆ Patent applied ÆÆ Can be mounted on any plane

50 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Description Drawing & Dimensions Titon CME3 Q Plus whole-house central mechanical extract ventilation unit. Product Codes Volt free switch inputs TP332A CME 3 Q Plus (Full assembly). TP332HA CME 3 Q Plus, humidity sensor (Full assembly).

Switch live inputs 352 CME 3 , humidity sensor (Full TP334HA Q Plus 252 assembly). Standards Conforms to requirements of UK statutory Building 340 310 Regulations and Technical Standards for Ventilation 490 460 and BRE 398. SAP Appendix Q tested (https://www.ncm-pcdb.org.uk/sap/pcdbsearch. jsp?pid=34) Performance The figures and compliance levels below relate to current SAP requirements. Exceeds requirements of Building Regulations Revised SAP guidance will have an effect on performance and up-to-date Approved Document L (England & Wales). figures can be found on the relevant product page at www.titon.co.uk. EU RoHS Directive compliant.

Conforms to requirements of EC council directives Specific fan Exhaust terminal Fan speed Energy Saving Trust Best relating to Electromagnetic Compatibility and power configuration* setting Practice Performance Compliant Electrical Safety: (W/l/s) 2006/95/EC (LVD), 2004/108/EC (EMC) EN 60335- 1:2002/A2:2006, EN 60335-2- 80:2003, A1:2004. Kitchen + 1 100% CE Marked. 0.18 Yes additional wet room variable Other non-UK info available on request. Kitchen + 2 100% 0.16 Yes Specification additional wet rooms variable Kitchen + 3 100% Dimensions (excluding ports): 0.17 Yes 310mm wide x 340mm long x 252mm high additional wet rooms variable Kitchen + 4 100% (excluding spigots) 0.19 Yes additional wet rooms variable Weight: 5 kg Kitchen + 5 100% 0.21 Yes Finish: Light grey / dark grey additional wet rooms variable Kitchen + 6 100% 0.25 Yes Materials additional wet rooms variable Housing: Talc Filled Polypropylene Guarantee period: 3 years (UK only) Figures taken from the BRE Test Results apply for both the standard and humidity versions. Electrical: 230V ~ 50/60Hz, 3A fuse *Number of wet rooms is based on SAP Q test criteria and does not correlate directly Installation: Install in accordance with with regulatory performance requirements. regulatory requirements, such as the Domestic Ventilation Compliance Guide (England & Wales) Test results available for use with 100mm ducting. and the Residential Ventilation Association recommendations. Nominal fan performance Maintenance: See product manual.

800 Nominal Speeds % Watts* 700 1 18 4 2 30 5 600 3 41 8 4 53 12 500 5 65 19

400 6 77 28 7 88 40 300 8 100 57 Boost speeds 100% variable 200

100

0 0 50 100 150 l/s Acoustic Data 0 100 200 300 400 500 600 m3/h

dB(A) @ dB(A) @ 3m % of Airflow 3m Hemispherical Spherical Product Max l/s flow Induct Casing Casing Inlet Breakout Breakout

42 l/s 41% 19 21 18

CME3 Q Plus 69 l/s 65% 35 32 29

104 l/s 100% 44 45 42

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 51 Features & Benefits

ÆÆ Purpose made product saves time and money compared with traditional joiner made access doors ÆÆ Excellent aesthetic appearance and finish ÆÆ Flush fitting door panels ÆÆ Visible picture frame surround smartly conceals cut out edges and contributes to a faster installation ÆÆ Smooth and enduring polyester powder coated finish ÆÆ Allows for painting if required For use in a wide ÆÆ Quick and straight forward to install range of dwellings ÆÆ Universal door handing ÆÆ Supplied with additional fixing anchors Titon’s steel framed access panels offer a lightweight (+50mm) for deeper wall and ceiling solution for access to the Titon CME when required. installations ÆÆ Hinged door panel with twist lock mechanism Titon’s Access Panels provide excellent access to our CME ÆÆ Quick release door panel mechanism fully unit that can be located in a ceiling void. They allow suitable removes to the door for maximum access access for applications where plastic access panels are not suitable and a fire rating is not required. ÆÆ Acoustic performance of 24dB (contact the Titon Technical team for more information)

Material and colour choice • Electro galvanised mild steel • Polyester powder coated smooth finish 20% gloss • White – RAL 9016

Installation advice • Please contact the Titon’s Technical team

Care and maintenance

HRV Accessories - Metal non-fire rated access panels Accessories - Metal non-fire HRV • Clean using a soft cloth with a mild detergent

• Spare keys available upon request CME Access Panel - Non Fire Rated - Non Fire CME Access Panel

Product Range

Overall Panel Product Frame Clear and Frame Door and lock type Number Fitting Opening Dimension

89801 605 x 605mm 575 x 575mm 635 x 635mm Hinged with APB600x600NFR twist lock

52 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Features & Benefits

ÆÆ Purpose made product saves time and money compared with traditional joiner–made access doors ÆÆ Fire rating independently tested by Exova Warrington fire ÆÆ Mineral wool insulation and draught stripped to reduce the opportunity of air leakage in application ÆÆ 32mm low profile frame ideal for installation with 15mm plaster board ÆÆ Flush fitting door panels with excellent aesthetic appearance and finish For use in a wide ÆÆ Visible picture frame surround smartly range of dwellings conceals cut out edges and contributes to a faster installation Titon’s picture frame access panels offer multi ÆÆ Enduring polyester powder coated finish performance, with 1 hour fire rated steel access panels that feature mineral wool and draught stripping, allowing ÆÆ Allows for painting if required for greatly reduced air leakage and an excellent acoustic ÆÆ Quick and straightforward to install performance. ÆÆ Universal door handing ÆÆ Hinged door panel with T-key lock mechanism Titon’s Fire Rated Access Panels provide excellent access to - Key lock available upon request our CME units that will be located in a ceiling void. They allow suitable access for applications where a 1 hour fire rating is ÆÆ Quick release door panel mechanism fully required. removes to the door for maximum access ÆÆ Acoustic performance of 33dB Material and colour choice • Electro galvanised mild steel • Glass wool insulation (45kg/m3) • Polyester powder coated smooth finish 20% Gloss • White – RAL 9016

CME Access Panel - Fire Rated - Fire CME Access Panel Installation advice • Please contact the Titon’s Technical team

Care and maintenance HRV Accessories - Metal 1 hour fire rated access panels Accessories - Metal 1 hour fire HRV • Clean using a soft cloth with a mild detergent • Spare keys available upon request • Lock and hinge mechanism can be oiled with a standard metal lubricant if required

Product Range

Overall Panel Product Frame Clear and Frame Door and Lock Type Number Fitting Opening Dimension

89802 605 x 605mm 560 x 560mm 650 x 650mm Hinged with T-key lock

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 53 Features & Benefits

ÆÆ Most efficient dMEV available ÆÆ Discreet aesthetic ÆÆ Easy clean design ÆÆ Quiet running, only 11dB(A) at 3m, low speed

Solitude ÆÆ Specific fan power down to 0.09w/l/s ÆÆ Two speed (selectable low speed) ÆÆ Unique high performance low noise impeller design Æ For use in small to medium Æ IPX4 rated ÆÆ Double insulated (requires no earth) sized dwellings ÆÆ Designed and manufactured in accordance Constant flow dMEV fan for bathroom, kitchen and utility with EN60335-2-80 Low Voltage Directive room applications with adjustable continuous and fixed and the EMC Directive (Electromagnetic boost speed settings. Solitude is the most efficient dMEV Compatibility) available.* ÆÆ Complies with Building Regulations Part F The Solitude constant flow dMEV fan is a discreet single fan suitable for new build or refurbishment projects. (England and Wales) Æ Solitude can be wall, ceiling or panel,** whilst the unique Æ Motor mounted on high quality sealed for life impeller design ensures powerful performance with minimal ball bearings noise. ÆÆ Capacitor type PCB power supply reducing The Solitude constant flow dMEV uses a boost with overrun PCB heat loss or highly efficient constant flow intermittent extract fan or highly efficient constant flow intermittent timer that is adjustable between 0 - 30 minutes, manually ÆÆ 18 month guarantee (UK only) activated via remote switch. ÆÆ PCDB listed for inclusion within SAP ÆÆ Meets stringent 5 Pa back pressure requirement Decentralised Mechanical Extract Ventilation

* Accurate at date of test ** To maintain the IPX4 rating when ceiling mounted, a kit must be used. Please contact us for availability of ceiling mounting kits.

54 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Description Drawing & Dimensions Solitude constant flow Decentralised Mechanical Extract Ventilation unit with run on timer. D A B C Product Codes TP210 Solitude with Overrun Timer

A 164 mm Standards E Designed and manufactured in accordance with ø E O B EN60335-2-80 (Low Voltage Directive) and the 70 mm EMC Directive (Electromagnetic Compatibility). Air C 46 mm performance measured according to ISO 5801 at 3 230V 50Hz, air density 1,2 Kg/m . CE marked. D 116 mm Solitude Ø E 99 mm Specification Dimensions: Ceiling IPX4 Kit 164mm x 164mm with 46mm projection Weight: 0.6Kg Gasket made of EPDM rubber Finish: White gloss RAL 9010, UV resistant Model TP202 to guarantee the IPX4 degree of protection against moisture Materials: Shock-proof ABS casing A 173 in case of ceiling installations. Guarantee period: 30 month (UK only) B 5 Electrical: 220-240 V ~ 50Hz Installation: Install in accordance with Performance regulatory requirements, such as the Domestic Max Sound Max Airflow Airflow Ventilation Compliance Guide (England & Wales) power pressure ambient m3/h l/s and the Residential Ventilation Association (W) dB(A) @ 3m temp °C recommendations. 83 23 32 Maintenance: Service, clean, replace subject to 47 13 23 local environment - see product manual. 36 10 2.5 19 50

29 8 13 Ducting Kits 21 6 11 Our ducting kits are recommended to maintain flow rates and are available in Ø100mm and 110x54mm Full Boost Selectable Trickle (low speed) rectangular. Kits contain; 3m duct, bends, grille and accessories. Calculated resistance rates are also included in ducting kit literature.

Ducted in room Direct exhaust through wall

Jumper switch settings Location Kitchen Wet room Kitchen Wet room

47m3/h 29m3/h 47m3/h 29m3/h Fan speed setting 13 l/s 8 l/s 13 l/s 8 l/s Jumper SFP w/l/s Rigid or 0.13 0.11 0.09 0.1 Installation Airflow flexible ducting 1 2 3

constant Curve at maximum speed 47m3/h - 13 l/s flow

constant P 36m3/h - 10 l/s flow 30 constant P 29m3/h - 8 l/s flow 25 constant P P 21m3/h - 6 l/s flow 20 P in room 47m3/h - 13 l/s

15 P P in room 29m3/h - 8 l/s

through Static Pressure Pa 10 P P 47m3/h - 13 l/s P = Jumper presentwall

through P P P 29m3/h - 8 l/s 5 wall

0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Volume Flow - l/s

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 55 Features & Benefits

ÆÆ Discreet aesthetic ÆÆ Easy clean design ÆÆ Quiet running, only 11dB(A) at low speed

Solace with 3m ducting ÆÆ Specific fan power down to 0.09w/l/s ÆÆ Two speed (selectable low speed) ÆÆ Comfort Boost on option ÆÆ Unique high performance low noise impeller design For use in small to medium sized ÆÆ IPX4 rated dwellings ÆÆ Double insulated (requires no earth) dMEV fan for bathroom, kitchen and utility room ÆÆ Designed and manufactured in accordance applications with adjustable continuous and fixed boost with EN60335-2-80 Low Voltage Directive speed settings. and the EMC Directive (Electromagnetic or highly efficient intermittent extract fan or highly efficient intermittent The Solace dMEV fan is a discreet single fan suitable for new Compatibility) build or refurbishment projects. Solace can be wall, ceiling or Æ panel mounted,** whilst the unique impeller design ensures Æ Complies with Building Regulations Part F powerful performance with minimal noise. (England and Wales) The Solace is available in three different versions: ÆÆ Motor mounted on high quality sealed for life ball bearings • Basic Fan: Boost manually activated via remote switch. ÆÆ Capacitor type PCB power supply reducing • Overrun Timer: Boost with overrun timer adjustable PCB heat loss between 0 - 30 minutes, manually activated via remote switch. ÆÆ 18 month guarantee (UK only) • Humidistat & Timer: Humidity sensor adjustable between 50 - 95%, activates Comfort Boost increasing airflow to an intermediate speed less intrusive than full

Decentralised Mechanical Extract Ventilation boost. Boost with overrun timer adjustable between 0 - 30 mins, manually activated via remote switch.

** To maintain the IPX4 rating when ceiling mounted, a kit must be used. Please contact us for availability of ceiling mounting kits.

56 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk P Jumper switchsettings kit literature. included inductingkitliterature accessories. Calculatedresistanceratesarealso rectangular. Kitscontain;3mduct,bends,grilleand rates andareavailableinØ100mm110x54mm Our ductingkitsarerecommendedtomaintainflow Ducting Kits local environment-seeproductmanual. Maintenance: Service,clean,replacesubjectto recommendations. and theResidentialVentilationAssociation Ventilation ComplianceGuide(England&Wales) regulatory requirements,suchastheDomestic Installation: Electrical: 220-240V~50Hz Guarantee period:30month(UKonly) Materials: Shock-proofABScasing Finish: Weight: 164mm xwith46mmprojection Dimensions: Specification 230V 50Hz,airdensity1,2Kg/m performance measuredaccordingtoISO5801at EMC Directive(ElectromagneticCompatibility).Air EN60335-2-80 (LowVoltageDirective)andthe Designed andmanufacturedinaccordancewith Standards TP200/HT SolacewithHumidistat&Timer TP200/RT SolacewithOverrunTimer TP200/BA BasicFan Product code available. Ventilation unitwithtimer/humidityvariants Solace DecentralisedMechanicalExtract Description P P P P 1 Jumper = Jumperpresent P P P P 2 WhiteglossRAL9010,UVresistant P P P P 3 0.6Kg Installation Install inaccordancewith through through through through in room in room in room in room wall wall wall wall Sales and Technical www.titon.co.uk Support +44(0) 1206713801 Airflow 13 l/s 13 l/s 8 l/s 6 l/s OFF OFF 8 l/s 6 l/s 3 . CEmarked.

Performance Ceiling IPX4Kit Drawing &Dimensions Curve atmaximumspeed at maximumspeed). are madeandonlyrunswhenliveisappliedtotheLSterminal(causingfanrun setting shouldberemoved.ThiswillensurethefanisoffwhenLandNconnections standard configuration.Allthree‘jumpers’thatusuallycontrolthefantricklespeed When usingtheSolaceasanintermittentextractfanwiringissame sold separately. *Tested inconjunctionwith2x2m100mmØducting,2x90°elbowsandoutsidegrille.Ductingkit

Static Pressure Pa Fan speedsetting Airflow Full Boost m 21 29 47 83 30 10 15 20 25 SFP w/l/s 3 Location 0 5 /h 0 Solace Airflow A 13 23 6 8 l/s Kitchen 47m 13 l/s 0.13 Ducted inroom Selectable Trickle(lowspeed) 8 3 /h power Max (W) 4 Wet room 29m Model 0.11 8 l/s B A 3 /h dB(A) @3m pressure Sound 11 13 32 23 13 Volume Flow-l/s Direct exhaustthrough wall TP202

173 ø E Kitchen O E 47m 5 13 l/s 0.09 3 /h ambient temp °C B in caseofceilinginstallations. of protectionagainstmoisture to guaranteetheIPX4degree Gasket madeofEPDMrubber Max 50 18 D Wet room 29m 8 l/s 0.1 3 /h C 23 Ø E D C B A 164 mm 116 mm 99 mm 70 mm 46 mm 57 28

TM Features & Benefits

ÆÆ Simple user friendly interface ÆÆ Compact sleek design ÆÆ 4 speed manual control (OFF feature TP536/ EU only) ÆÆ 7 day programmable automatic Speed 1 timer aura-t (TP536/EU only) ÆÆ Real-time fan commissioning for all speeds ÆÆ Filter change alert indicator ÆÆ Internal humidity threshold adjustment ÆÆ Kitchen & wet room boost overrun time adjustment ÆÆ Programmable boost inhibit (TP536/EU only) ÆÆ Switch configuration menu For use with Titon HRV Q Plus ÆÆ Time and day display Range ÆÆ Backlight with automatic dimming aura-tTM ÆÆ Real-time indication of HRV status and

HRV Q Plus Basic Programmer Q Plus Basic Programmer HRV is a simple yet striking touchscreen controller for programming, commissioning and occupancy control for operating mode Titon’s range of Mechanical Ventilation Heat Recovery ÆÆ Optional passcode protected commissioning (MVHR) units. and setup screens The aura-tTM touch screen controller allows straightforward ÆÆ Summer bypass configuration menu operation of ventilation speeds. Offering a display that is back lit. ÆÆ 8 hour timeout for manual operation (TP536/EU only) aura-tTM provides the following functions: ÆÆ Fan failure indication • Digital 4 speed switch ÆÆ Manual boost inhibit (TP536/GBR only) • Auto timed speed mode (TP536/EU only) ÆÆ 1 hour timeout for Speeds 1,3 and 4 • 7-day, 4 events per day programmable Speed 1 timer (TP536/GBR only) (TP536/EU only) • Filter change indicator Description

TM • Internal MVHR humidity set point adjustment Titon’s aura-t HRV is for commissioning and monitoring a Titon TP***B HRV Q Plus unit. • Boost inhibit functions linked to timed Speed 1 (avoiding night time boosting via either switch inputs or humidity) aura-tTM is an icon based rather than language specific Product Code controller. aura-tTM - TP536

Specification Dimensions: 87mm wide x 87mm high x 24mm deep supplied with 3 metre connection cable.

Weight: 185g Finish: High gloss finish Materials: ABS Guarantee period: 1 year Electrical: 12V DC

58 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk

® Features & Benefits

ÆÆ User friendly interface

ÆÆ Fan speed commissioning

ÆÆ Multiple languages available

ÆÆ Digital 3 or 4 speed switch (user selectable)

ÆÆ 7 day, 8 programmable fan speed settings

ÆÆ Boost inhibit

auramode ÆÆ Compact design

ÆÆ Filter change indication

ÆÆ Internal MVHR humidity sensor set point

ÆÆ Compatible with TP***B MVHR models For use with Titon HRV Q Plus ÆÆ Kitchen boost overrun timer adjustment Range ÆÆ Wet room boost overrun timer adjustment auramode®

HRV Q Plus Basic Programmer Q Plus Basic Programmer HRV is a simple yet powerful LCD display for programming, commissioning and occupancy control for ÆÆ Volt free and mains voltage MVHR Switch Titon’s range of Mechanical Ventilation Heat Recovery configuration setup (MVHR) units. ÆÆ High flow boost setting (speed 4) The auramode® allows straightforward operation of ventilation speeds at a click of a button. Offering a display that is back ÆÆ Summerboost boost on/off selection lit with adjustable light and contrast settings. ÆÆ Single button operation for everyday basic auramode® provides the following functions: functions Digital 4 speed switch (speeds 1, 2, 3 or 4) ÆÆ Low voltage, hard wired status programmer Auto timed speed mode 7-day, 8 settings per day programmable speeds Filter change indicator with adjustable (1-24 months independent filter check and filter change intervals) Description auramode® Internal MVHR humidity set point adjustment Titon’s HRV is for commissioning and monitoring a Titon TP***B HRV Q Plus unit. Boost inhibit functions linked to timed speeds (avoiding night time boosting via either switch inputs or humidity)

auramode® is a multi-language controller where the user can Product Code select from the following languages: auramode® - TP524

●● English ●● Dutch Specification French ●● Dimensions: 86mm wide x 86mm high x 16mm German ●● deep Supplied with 14 metre connection cable (plug ●● Italian connection to auramode®, 4 wire to MVHR) ●● Spanish ●● Polish Weight: 185g ●● Lithuanian ●● Russian Finish: High gloss finish ●● Ukrainian Materials: ABS ●● Slovenian ●● Hungarian Guarantee period: 1 year Electrical: 12V DC

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 59 Features & Benefits

ÆÆ User friendly interface showing system status, fan speeds/air temperature and more ÆÆ Boost alert triggers a warning message when the HRV has been left in boost ÆÆ Grants the occupant accessibility and V & VT control ® ÆÆ PIN protected menu structure for commissioning ÆÆ Low power consumption ÆÆ Individual supply/extract fan speed settings ÆÆ Separate kitchen and wet room boost function settings HRV Q Plus Controller HRV ÆÆ Demand control features via 2 x 0-10V DC proportional sensor inputs (power supplied

from main PCB, RH, CO2, Air quality and For use with Titon HRV temperature) aurastat Q Plus Range gives enhanced ÆÆ Fully automatic summer bypass commissioning capabilities ÆÆ Intelligent frost protection Æ aurastat® is a low voltage, intelligent controller with LCD Æ Boost delay display for commissioning and monitoring a Titon TP***B ÆÆ Boost inhibit within selected time zones HRV unit. It is wired to the unit but situated remotely. ÆÆ Running hours recorder aurastat® V also has a commissioning only option. Once ÆÆ Internal MVHR humidity sensor setpoint programmed, the HRV unit runs without the need for the controller. ÆÆ Fully adjustable SUMMERboost® speed (linked to automatic bypass) aurastat® is controlled via buttons that configure and monitor Æ the HRV using five different menu systems: Æ Programmable timer option Mains voltage or volt free boost switching

ÆÆ Monitor and control ‘Run’ menu ÆÆ User set up ‘SETUP1’ Description ® ÆÆ Service and set up ‘SETUP2’ Titon aurastat HRV controller for commissioning and monitoring a Titon HRV Q Plus unit. ÆÆ Commissioning and installation ‘SETUP3’ ÆÆ Reset ‘RESET4’ Product Codes The display is a back lit 90mm LCD screen which combines a aurastat® V - TP526 mixture of icons, text and figures aurastat® can be used to set aurastat® VT - TP534 and control a number of features including: ÆÆ Boost alert timer ÆÆ Summer Mode, Summer Bypass and SUMMERboost® Standards settings Conforms to requirements of EC council directives ÆÆ Duct heater settings relating to Electromagnetic Compatibility and Electrical Safety: 2006/95/EC (LVD), 2004/108/EC (EMC) EN ÆÆ Room sensor set points 60335-1:2002/A2:2006, EN 60335-2-80:2003/A1:2004 ÆÆ Internal humidity settings CE marked ÆÆ Continuous, boost and set back speeds Patented and Registered design

The home occupant has access to set a number of features themselves, such as: Specification ÆÆ 24-hour clock Dimensions: 106mm wide x 141mm high x 25mm deep ÆÆ Day of week display Weight: 185g ÆÆ Back light brightness : High gloss finish ÆÆ Boost overrun timer Finish ÆÆ Boost delay timer Materials: ABS ÆÆ Boost inhibit times Guarantee period: 3 years (UK only) ÆÆ Internal humidity sensor set point Electrical: 12V DC ÆÆ Filter change alert interval and reset

aurastat® VT has the additional features of programmable weekly timers that are used to setback or boost the ventilation rates at specific times.

aurastat® is used to set up and control specific versions of Titon’s HRV units. For compatibility please contact us on +44 (0)1206 814879 or [email protected].

60 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk

® Features & Benefits

ÆÆ Meets guidelines for occupant accessibility ÆÆ Increase occupant awareness of system operation ÆÆ Can be sited remotely from unit in an easy to access location ÆÆ Discreet design auralite ÆÆ Fits a standard UK pattress box ÆÆ Compatible with Titon HRV units

For use with Titon HRV Q Plus Basic Indicator Q Plus Basic Indicator HRV HRV Q Plus Range

® auralite is a low voltage, hard wired status indicator Specification sited remotely from the unit. Dimensions: 90mm wide x 90mm high x 12mm deep auralite® has six LEDs which display; Weight: 50g Normal - the system is running at continuous speed (normal mode) or the unit is running at setback speed if this Finish: High gloss finish light is flashing Materials: Polycarbonate Frost - the unit is in automatic frost protection mode. : 1 year TP519 if flashing - internal frost protection - indoor Guarantee period temperature low - both fans stop. Electrical: 12V DC Filter - the filters require changing Installation: Suitable for mounting on a standard UK Boost - the system is running in boost speed. recessed pattress box. Supplied with screws. TP518 - If flashing indicates boast alert ® TP519 - If flashing indicates SUMMERboost /speed 4 Features & Benefits Summer - the unit is in summer bypass mode ●● Meets guidelines for occupant accessibility Fault - there is a fault with the system and the installer should ●● Increases occupant awareness of system operation be contacted. ●● Can be sited remotely from unit in an easier to access location Normal/Boost - alternating indicates demand control from ●● Discreet design proportional sensors (only applicable with TP519) ●● Fits a standard UK patress box auralite® is to be used with Titon’s HRV units. For compatibility please contact us on +44 (0)1206 814879 or [email protected]. Description Titon auralite® remote status indicator for use with Titon HRV Q Plus unit. Product Code auralite® - TP518 (Compatible with TP***HMB Only) auralite® - TP519 (Compatible with TP***B Only) Standards Meets guidelines for occupant accessibility as set out in NHBC Standards 2017 - Section 8.3.6: MVHR systems should include visual indicators showing maintenance and serving requirements, and mode of operation. These should be visible from within the insulated envelope, not obscured from view, and be simple to use.

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 61 These products are for use with MVHR or CME units, depending on ventilation system design specification. Switches

EHC1 Humidistat Internal EHC2 Humidistat External Boost Switch (latching) Boost Switch (momentary) Adjustment (TP500) Adjustment (TP501) (TP502) (TP503) Activates Boost function on all HRV and Activates Boost function on all HRV and Activates Boost function on all HRV and Activates Boost (timer overrun) CME units (volt free) CME units (volt free) CME units function on Q Plus units only

Summer Mode Switch Boost Ceiling Switch Room Thermostat SUMMERboost® Switch (latching) (TP506) (momentary) (TP509) (TP522) Manual operation of Summer Mode Activate the timer overrun on Automatic operation of Summer Disables SUMMERboost® on HRV on HRV A suffix units without Summer Q Plus units only Mode on HRV A suffix units only. Can be HMB suffix units only. Can be used on Bypass. Can be used on Aurastat with used on Aurastat with summer mode. Aurastat® and Auramode®. summer mode.

Multifunction 3 Speed Switch PIR Movement Sensor Touch Button Timer (TP505) (TP508) (TP580) (TP581) Enables multiple switching configurations A 3 position to change A volt free contact sensor for Touch button Timer with volt and mains voltage switching for between setback, continuous or boost boost mode. free contact for boost mode. Q Plus units running speeds.

PIR Presence/Absence Programming Handset Detector (TP583) for TP583 (TP584) Compact ceiling mounted PIR presence/ Compact infrared handset used for the basic absence detector with programming of PIR. volt free contact for boost mode.

62 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk RSQ - Room Air Quality Sensor • Measures the concentration of over 30 different contaminants • Transforms the signal to a standard analogue output of 0-10 Vdc or 0-20 mA • Concentration is measured by the use of an air quality sensor which is maintenance-free in a normal environment

Sensors • Monitors the air quality by a unique oxidising element that varies in resistance with respect to the contaminant gases • Output signal corresponds to the combined concentration of more than 30 gases typically found in indoor environments • Provides a more accurate representation of the

actual air quality than a CO2 sensor

For use with Titon HRV Q Plus The RSQ sensor is able to detect: Range • Iso-butane, Methane, Ethane, Propane Sensors designed to work in conjunction with aurastat® compatible TP***B HRV Q Plus units. Wired to the • Acetone, Methanol, N-pentane, Benzene TP***B HRV unit, the sensors are set and controlled via • Sulphur dioxide, Chlorine, Carbon dioxide aurastat®. • Vinyl chloride, Methyl chloride Compatible with TP***B HRV Units Compatible with TP***B HRV RST - Room Temperature Sensor • Precision temperature sensing • Tobacco smoke, Alcohol, Formaldehyde • Fast response to changes in thermal comfort conditions • Equipped with a platinum sensor Compatible with HRV Q Plus units (aurastat® controller) • 0-10Vdc/0-20mA analogue output signal

Description RCE - Room CO2 sensor Sensors designed to work in conjunction with aurastat® • Measures the concentration of CO2 from 450 to 1850 ppm in air compatible TP***B HRV Q Plus units. • Transforms the signal to a standard analogue output of 0-10 V or 0-20 mA Product Codes

• The CO2 concentration is measured using a NDIR RST: Room Temperature Sensor - TP543 sensor which is self-calibrating and maintenance free in a normal environment RSQ: Room Air Quality Sensor - TP540

RCE: Room CO2 Sensor - TP541 RSH: Room Humidity Sensor - TP542 The CO2 level is a parameter that determines the quality of the interior climate. Standards

The CO2 level is a good benchmark for the level of ventilation Conforms to requirements of EC council directives in a room. relating to Electromagnetic Compatibility and Electrical Safety: 2006/95/EC (LVD), 2004/108/EC (EMC) EN 60335-1:2002/A2:2006. CE marked. RSH - Room Humidity Sensor • Enhanced humidity sensing capabilities Specification • Suited to applications where precise, stable humidity Dimensions: 104.5mm wide x 74.5mm high x 24mm sensing is required deep • Maintains highly accurate control using built in self Weight: 91-160g calibration and a 0-10 Vdc/0-20 mA analogue output signal. Guarantee period: 3 years (UK only) Electrical: 12V DC

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 63 Features & Benefits

ÆÆ Unique combined extract fan/trickle ventilator ÆÆ Suitable for all window types ÆÆ Integral with window, ideal for refurbishment situations ÆÆ Avoids damage or penetration of building

Vent-Trex fabric ÆÆ Easy to install ÆÆ Saves wall space ÆÆ Low installation costs compared to For use on PVCu, timber or traditional extract ventilators aluminium windows ÆÆ Bathroom version – single speed (15 l/s) ÆÆ Kitchen version – two speed (60 l/s and 30 Vent-Trex is a unique combined overhead extract fan and l/s) trickle ventilator for kitchen and bathroom that fits within the window aperture on top of the window frame. ÆÆ 2500mm2 EA minimum Vent-Trex is ideal for refurbishment situations where wall ÆÆ Low energy usage penetration is undesirable, as it does not damage the fabric ÆÆ Easy to clean of the building or where external aesthetics need to be preserved. ÆÆ Easy to maintain Æ It provides a trickle ventilation performance Equivalent Area Æ IP24 rating (EA) of 2500mm2 minimum and extract ventilation rates to ÆÆ Pull cord switch and power light (dependant suit either kitchen or bathroom. on model) ÆÆ Humidistat option available (integral or remote)

Over-head extract fan / trickle ventilator extract Over-head ÆÆ Available with remote PSU (SELV) option for bathrooms ÆÆ Continuous power or continuous running versions ÆÆ Variable speed version ÆÆ Suitable for use in conservation areas ÆÆ 2-year guarantee

64 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Details Optional Extras Units can be supplied with or without external mash. Units can be supplied as Permanent Ventilators i.e. no slide (Not available for Cord Control Units). Meanings Remote PSU To provide extra low voltage capability for use in bathrooms SELV. Minimum length mm Minimum unit length to achieve stated airflow mm Airflow l/s Standard Bathroom Fan Options Pull Cord or Ceiling Switch must be pulled to switch unit on and to allow humidity sensing to Standard Integral PSU + Pull Cord 420 520 15 * operate. Standard Remote PSU + Pull Cord 390 505 15 * Continuous Power Standard Remote PSU + Ceiling switch 290 405 15 * Pull Cord or Ceiling Switch manually operates the fan, unit will always respond to humidity change. Standard Integral PSU + Pull Cord + Humidistat 420 520 15 * Standard Remote PSU + Pull Cord + Humidistat 390 505 15 * Continuous Running Fan will run at low speed continuously and Standard Remote PSU + Ceiling Switch (L) + Humidistat 390 505 15 * increase to the higher speed on pulling the Pull Continuous Power Integral PSU + Pull Cord + Humidistat 420 520 15 * Cord. Continuous Power Remote PSU + Pull Cord + Humidistat 390 505 15 * Cord Control Continuous Power Remote PSU + Ceiling Switch (M) + Humidistat 390 505 15 * The unit has two Pull Cords one each side. One to open the slide, one to close the slide. Also Continuous Running Integral PSU + Pull Cord 420 520 8.6/11.8* switching the unit on & off. Continuous Running Remote PSU + Pull Cord 390 505 8.6/11.8* Variable Speed Cord Control Integral PSU 420 520 15 * Variable boost speed – used to reduce fan boost speeds in conjunction with open flued appliances, Cord Control Remote PSU 390 505 15 * to avoid fumes being pulled back into property. Cord Control Integral PSU + Humidity 420 520 15 * (integral potentiometer adjustment). Cord Control Remote PSU + Humidity 390 505 15 * Humidistat Measures a change in Humidity to trigger the fan to Kitchen Fan Options run or increase in speed.

Standard Integral PSU + Pull Cord 450 1200 30/60 x Ceiling Switch Momentary switch (M) - Using Pull Cord to break x Standard Integral PSU + Ceiling Switch (L) 450 1200 30/60 contacts. Standard Integral PSU + Pull Cord + Humidistat 450 1200 30/60 x Latching Switch (L) using normally open and common contacts. Standard Integral PSU + Ceiling Switch (L) + Humidistat 450 1200 30/60 x Fitting, wiring and operation instructions are Continuous Power Integral PSU + Pull Cord + Humidistat 450 1200 30/60 x available, please contact Titon Technical Dept Continuous Power Integral PSU + Ceiling Switch (M) + Humidistat 450 1200 30/60 x Continuous Running Integral PSU + Pull Cord 520 1200 8.7/21.6 x More information Cord Control Integral PSU 450 1200 30/60 x www.titon.co.uk or 01206 713800 Cord Control Integral PSU + Humidistat 450 1200 30/60 x

Variable Speed Integral PSU 450 1200 30/60 x * Single Speed x Two Speed Please contact sales quoting unit type to receive Vent Trex Quotation/Order Sheet. Performance 80 Equivalent Area (EA) - 2500mm2 (minimum) Free Area (mm2) - Bathroom model: Integral PSU (length 520-2500mm): 5280mm2 min Remote PSU (length 405-2500mm): 5280mm2 min Kitchen model: Length 880-2500mm: 9000mm2 30 Details 230V AC Voltage / Power Consumption (standard version) 80 12V Bathroom – 3.95W @ 15 l/s (540mm length) (Integral PSU) To Suit 24V Kitchen – 21W @ 60 l/s (1200mm length) (Integral PSU) Window Head 50 Motor protection: IP24 Rating CE marked according to LVD and EMC directives Configurations

Window Finishes 10 White finish as standard to RAL 9010. Can be supplied in different colours. Packer May External Canopy and Internal fan can be coloured independently. Details Be available on request. Required Configurations Handing - Pull Cord and Cable Entry can be either on the left or right side (viewed from inside the property) Flex entry to the unit can be either from the front or the end.

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 65 Features & Benefits

ÆÆ Ideal for kitchen, bathroom, utility and general extract applications ÆÆ The powerful in-duct mounted mixed flow fan has been designed to produce higher working pressures for applications that

Extract Fans require high airflows

ÆÆ High quality ball bearing motors

ÆÆ 3 speed operation (hard wired)

ÆÆ Ingress protection to IP55 For use in residential or ÆÆ Max operating temperature 50°C non-residential applications ÆÆ Overrun timer

The new Mixed Flow inline fan from Titon is a high ÆÆ Protection Class II performance fan with 3 speeds. It is suitable for bathrooms, kitchens and general extract applications.

It is easily installed and maintained, ideal for removing internal condensation; eliminating condensation and mould growth within the home.

With high pressure and low noise levels, it allows Titon’s Mixed Flow Inline Fan Mixed Flow fan to work effectively in the home, causing less intrusion into daily life whilst helping ventilate to an sufficient level.

66 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Product Codes Performance Details

Ø100mm - TP220T 100mm - inline mixed flow fan Ø125mm - TP221T Ø150mm - TP222T 200 High Ø160mm - TP223T 180 Medium Standards 160 Low 140 Conforms to requirements of EC council directives Relating to Electromagnetic Compatibility and 120 Electrical Safety: EN60335-1, EN60335-2-80, EN55014-1, 100

EN55014-2, EN61000-3-2, EN61000-3-3 80 CE Marked. Pressure (Pa) 60

Specification 40 Materials: Black plastic 20

0 Guarantee Period: 1 year 0 20 40 60 80 100 l/s 100 200 300 400 m3/h Electrical: 230V - 50/60Hz, 3A fuse Volume Flow

Power Rating 125mm - inline mixed flow fan Product Product 220-240V~ 3A fuse Size Code 140 High 50Hz 60Hz Medium Ø100 TP220T 30W 38W 120 Low Ø125 TP221T 30W 38W 100 Ø150 TP222T 60W 84W Ø160 TP223T 60W 84W 80

Maintenance: Service subject to local environment - see product 60 manual. Pressure (Pa) 40

20

0 20 40 60 80 100 120 140 l/s 0 100 200 300 400 500 m3/h Volume Flow

150/160mm - inline mixed flow fan 250 High Medium

200 Low

150 Drawing & Dimensions 100 Pressure (Pa) Product Product G H Weight Size Code ØA ØB C D E F (CRS) (CRS) (Kg) 50 Ø100 TP220T 98 173 111 295 100 195 135 176 1.9 Ø125 TP221T 123 173 111 269 100 195 135 176 2 0 Ø150 TP222T 148 200 131 289 110 231 136 214 3 50 100 150 200 l/s 0 Ø160 TP223T 158 200 131 271 110 231 136 214 3.1 100 200 300 400 500 600 700 m3/h Volume Flow D ØB

ØA

E C

H G F

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 67 Features & Benefits

ÆÆ IPX4 protection degree

ÆÆ Aesthetic front flat cover for modern interior design easily removed for cleaning

Æ

Extract Fans Æ Rigid optimised spigot support preventing distortion with strengthened guard and design to maximise airflow

ÆÆ Integral back-draught shutter fitted as standard to prevent air flowing back into the For use in residential or room when the fan is off non-residential applications ÆÆ Low power consumption: 100mm model has less than 8 watts operating power Ideal for air-extraction in bathroom, toilet and kitchens. consumption for energy saving Suitable to extract stale air directly to the outside or through short length ducting. Units can be wall/panel, ÆÆ Totally recyclable plastic components, ceiling and window mounted. environmentally friendly

ÆÆ Double insulated: no earth connection is Versions required Run-on timer - The fan is equipped with a timer circuit adjustable from ± 1‘ to 25’. Operation: after switching off, ÆÆ Unique design winglet-type impeller, the fan continues to run for the pre-set period of time. providing enhanced aerodynamic properties, - The fan is provided with an electronic Humidistat-timer low noise and increased efficiency Intermittent Fans - Axial Intermittent Fans circuit having a humidity sensor on board (adjustable from 50% to 95% RH) and a timer, adjustable from ± 1’ to ÆÆ Electrical supply 220-240 V ~ 50-60Hz 25’. Operation: when the percentage of relative humidity is higher/lower than the pre-set threshold, the fan is automatically activated/deactivated. After switching off, the fan continues to run for the pre-set period of time.

68 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Performance Details Ceiling IPX4Kit local environment-seeproductmanual. Maintenance: Service,clean,replacesubjectto recommendations. and theResidentialVentilationAssociation Ventilation ComplianceGuide(England&Wales) regulatory requirements,suchastheDomestic Installation: Electrical: 220-240V~50Hz Guarantee period:2years(partsonly) Materials: Shock-proofABScasing Finish Specification at 230V50Hz,airdensity1.2Kg/m Air performancemeasuredaccordingtoISO5801 EMC Directive(ElectromagneticCompatibility). EN60335-2-80 (LowVoltageDirective)andthe Designed andmanufacturedinaccordancewith Standards Run-on TimerØ150mm- TIFA150T, IntermittentFanAxialØ150mm Run-on TimerØ120mm- TIFA120T, IntermittentFanAxialØ120mm Humidity andTimer- TIFA100HT, IntermittentFanAxialØ100mm Product Codes Ø150 Ø120 Ø100 Model 10 20 30 40 50 60 : WhiteglossRAL9010,UVresistant 0 0 0 Installinaccordancewith Airflow 212 130 m 75 3 /h Sales and Technical www.titon.co.uk Support +44(0) 1206713801 TP241HT 10 Airflow TP243T TP242T 50 59 36 21 l/s Model 20 3 . CEmarked. pressure B A Pa max Static 48 37 24 10 TP202 173 5 power

30 Max (W) 24 14 8 TP205/ Ø120 196 5 dB(A) @3m Drawing &Dimensions pressure Dimensions inmm Sound 40 42 34 26 Model TP205/ Ø100 Ø150 Ø120 150 Size Ø150 230 5

164 218 184 ceiling installations. degree ofprotectionagainstmoistureincase Gasket madeofEPDMrubbertoguaranteetheIPX4 50 ambient temp °C A Max 50 TIFA A 20 70 97 81 B 60 46 52 48 C 250 70 116 149 129 D m l/s 3 /h Ø E 148 119 T T T 99 IF IF IF

A A A ø E 150T 120T 10H O E Weight T 1.2 0.9 0.6 Kg

B D 69 C Features & Benefits

ÆÆ IPX4 protection degree

ÆÆ Aesthetic front flat cover for modern interior design easily removed for cleaning

Æ

Extract Fans Æ Removable filter in PP to protect the impeller and the motor. Easy to be removed for cleaning

ÆÆ Integral back-draught shutter to prevent air flowing back into the room when the fan For use in residential or is off non-residential applications ÆÆ Improved performance thanks to the unique air straightener to optimise performance and Ideal for air-extraction in bathroom and small premises. reduce power consumption A powerful extract fan, designed to overcome the resistances of long ducting systems. Units can be wall/ ÆÆ Totally recyclable plastic components, panel and ceiling mounted: designed for surface or flush (plasterboard) installation. environmentally friendly. Version ÆÆ Double insulated: no earth connection is Humidistat & timer - The fan is provided with an electronic required circuit having a humidity sensor on board (adjustable from 50% to 95% RH) and a timer, adjustable from ± 1’ to ÆÆ Forward curved centrifugal impeller, 25’. Operation: when the percentage of relative humidity providing enhanced aerodynamic properties, is higher/lower than the pre-set threshold, the fan is low noise and increased efficiency. automatically activated/deactivated. After switching off, the fan continues to run for the pre-set period of time. ÆÆ Electrical supply 220-240 V ~ 50-60Hz Intermittent Fans - Centrifugal Intermittent Fans

70 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Product Codes Drawing & Dimensions TIFC100HT, Intermittent Fan Centrifugal Ø100mm 17 96.5 Humidity and Timer - TP251HT 241.5 Standards Designed and manufactured in accordance with EN60335-2-80 (Low Voltage Directive) and the EMC Directive (Electromagnetic Compatibility). 96

Air performance measured according to ISO 5801 Ø at 230V 50Hz, air density 1.2 Kg/m3. CE marked. Specification Finish: White gloss RAL 9010, UV resistant

Materials: Shock-proof ABS casing

Weight: 1.87 Kg

Guarantee period: 2 years (parts only)

Electrical: 220-240 V ~ 50Hz

TIFC Installation: Install in accordance with regulatory requirements, such as the Domestic Dimensions in mm Ventilation Compliance Guide (England & Wales) and the Residential Ventilation Association recommendations.

Maintenance: Service, clean, replace subject to local environment - see product manual.

Ceiling IPX4 Kit

TP206/ Model Ø150

A 255 Gasket made of EPDM rubber to guarantee the IPX4 degree of protection against moisture in case of B 5 ceiling installations. Performance Details

250 TIFC100HT

200

150

100

50

0 0 5 10 15 20 25 30 l/s 0 20 40 60 80 100 m3/h

Airflow Static Max Sound Max Airflow Model m3/h pressure power pressure ambient l/s max Pa max (W) dB(A) @ 3m temp °C

Ø100 97/61 27/17 235/146 28/17 38/27 50

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 71 Need products to work with different ventilation systems? What’s more, specification is simple. The EA (Equivalent Area) is marked on each product for easy reference and vent and canopy or grille combinations have been tested in accordance with BS EN 13141:2004. The wide choice outlined in this brochure

Overview means compliance is possible when used with other products from Titon’s mechanical ventilation range: • System 1 - Extract fans • System 3 - Continuous mechanical ventilation systems • System 4 - Continuous mechanical supply and extract with heat recovery • Please phone for available colours/finishes. Trickle ventilator range • Remote Control option available on some of Titon’s range of window trickle ventilators includes improved Titon’s slot ventilator range. designs which assist in compliance with Ventilation For full product dimensions and fixing information, Regulations in England & Wales. Aluminium or PVCu models please visit www.titon.co.uk and navigate to the are available which offer increased ventilation that other relevant product’s documentation page. ventilator manufacturers cannot match. This makes both the specifier and the window fabricators’ jobs easier. The specifier can pick Titon products to ensure compliance for

Window Ventilators Window a choice of ventilation systems in different dwelling types, without constant specification change. The fabricator is safe in the knowledge that only the minimum number of ventilators required need to be used to achieve this compliance.

Typical Trimvent® Select Xtra pack

Thanks to our engineering expertise, the Trimvent® Select Xtra gives optimum airflow (and therefore Equivalent Area) utilising existing slot sizes. Specifically developed for Part F of the Building Regulations, Ventilation (England & Wales), and to improve performance for requirements throughout rest of the UK and Europe.

The Select Xtra is available in sizes suitable for both new build or replacement situations.

• No need to alter overall window designs to • Slot sizes as standard but products approximately accommodate more vents or find additional vent 60% more efficient for airflow locations. Select Xtra will do the job • Based on extremely successful Trimvent® Select • Improved opening gives optimum Equivalent Area principle

Trimvent® Select Xtra S13

XS13 Ventilator & XC13 Canopy

Slot Ventilators For use on PVCu, timber or aluminium windows. Clip fix version available. • Equivalent Area (mm2): 4400, 5000 (clip fix 4000, 5000) • Free Area (mm2): 4106 (XS) and 4804 (XC), 5080 (XS) and 6055 (XC). • Product Length: 411, 497 • Overall Slot Size: 367, 450 x 13

72 Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk Trimvent® Select Xtra S16

XS16 Ventilator & XC16 Canopy For use on PVCu or timber windows. • Equivalent Area (mm2): 4600 • Free Area (mm2): 4507 (XS) and 4990 (XC) • Product Length: 366 • Overall Slot Size: 312 x 16 Trimvent® Select Xtra R16

XR16 Ventilator & XHD16 Grille (or XC16 Canopy) For use on timber windows. • Equivalent Area (mm2): 4600 • Free Area (mm2): 4523 (XR) and 4608 (XHD) • Product Length: 351 • Overall Slot Size: 352 x 16 (with 22 recess) Trimvent® Select S13

S13 Ventilator & C13 Canopy For use on PVCu, timber or aluminium windows. Clip fix version available. • Equivalent Area (mm2): 1700, 2700 • Free Area (mm2): 2000, 4000 • Product Length: 267, 412 • Overall Slot Size: 223, 367 x 13 Trimvent® Select E18

E18 Ventilator & GS18 Grille For use on PVCu overhead window sections. • Equivalent Area (mm2): 4200 • Free Area (mm2): 4000 • Product Length: 372 (E18) and 424 (GS18) • Overall Slot Size: 366 (E18) and 408 (GS18) x 18 SF Xtra

SF Xtra Ventilator & SF Canopy For use on PVCu or aluminium windows. Also available in bar length. • Equivalent Area (mm2): 2500, 4000, 5000 • Free Area (mm2): 3000, 4000, 5000, 6000 • Product Length: 294, 374, 400, 419, 434, 529 • Overall Slot Size: (Length; see Product Fixing Instructions) x 13 or 16 SF Xtra Sound Attenuator

SF Xtra SA Vent & SF SA Canopy For use on PVCu, timber or aluminium windows. • Equivalent Area (mm2): 2500 • Free Area (mm2): 3470 • Product length: 464 • Overall Slot Size: 367 x 13

• Various combinations available to provide different levels of sound attenuation from

Dn,e,w(C;Ctr) = 32 (-1;-1) dB through to Dn,e,ww (C;Ctr) = 44 (-1;-3) dB

Sales and Technical Support +44 (0) 1206 713801 www.titon.co.uk 73 894 The Crescent, Colchester Business Park, Colchester, CO4 9YQ

Tel: +44 (0) 1206 713800 Email: [email protected] Web: www.titon.co.uk www.titondirect.co.uk BM384 Iss. 01 (Mar 19)