Operating/Safety Instructions Consignes De Fonctionnement/Sécurité Instrucciones De Funcionamiento Y Seguridad IMPORTANT: IMPORTANT : IMPORTANTE: Read Before Using Lire avant usage Leer antes de usar Operating/Safety Instructions Consignes de fonctionnement/sécurité Instrucciones de funcionamiento y seguridad GLR500 GLR825 Call Toll Free for Pour obtenir des informations Llame gratis para Consumer Information et les adresses de nos centres obtener información & Service Locations de service après-vente, para el consumidor y appelez ce numéro gratuit ubicaciones de servicio 1-877-BOSCH99 (1-877-267-2499) www.boschtools.com For English Version Version française Versión en español See page 6 Voir page 18 Ver la página 29 h i g f a e d b c 9 8 7 6 5 4 3 2 1 10 11 12 13 14 15 22 18 17 16 23 IEC 60825-1:2007-03 ≤ 1mW @ 635 nm 2 Laser Radiation. Do not stare into the beam. Class 2 Laser product. 19 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice 50,6/24/2007 Radiación láser. No mire al rayo. 21 Producto láser de Clase 2. Cumple con las normas 21 CFR 1040.10y 1040.11, excepto por las desviaciones conforme al Aviso para láseres 50 del juio de 2007 20 Rayonnement laser. Ne regardez pas directement dans le faisceau. Produit laser de Classe 2. Conforme à 21 CFR 1040.10 et 1040.11, sauf pour les écarts suivant l’ Avis laser 50, 24/6/2007 24 29 28 27 10 26 24 25 -2- A B 1.6 ft 1.6 ft C D t 1.6 f t 1.6 f E F min 1.6 ft -3- max 2 G H 1 2 E 1 90˚ 3 1 2 I 2 3 J 1 E 3 3 E 2 1 90˚ 1 90˚ 2 2 3 K 1 L E B1 A 3 B3 2 90˚ 90˚ 1 B2 -4- M 2.0 ft 2.0 ft N O 30 31 DLA001 DLA002 -5- General Safety Rules ! IEC 60825-1:2007-03 WARNING LASER RADIATION. AVOID DIRECT EYE EXPOSURE. DO ≤ 1mW @ 635 nm NOT stare into the laser light source. Never aim light at another person or 2 Laser Radiation. Do not stare into the object other than the workpiece. Laser light can damage your eyes. beam. Class 2 Laser product. Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant Read all instructions. Failure to follow all instructions listed to Laser Notice 50,6/24/2007 ! WARNING Radiación láser. No mire al rayo. below may result in electric shock, fire and/or serious injury. Producto láser de Clase 2. Cumple con las normas 21 CFR 1040.10y 1040.11, Do not direct the laser beam at persons or animals and do not stare excepto por las desviaciones conforme al Aviso para láseres 50 del juio de 2007 into the laser beam yourself. This tool produces laser class 2 laser Rayonnement laser. Ne regardez pas directement dans le faisceau. Produit radiation and complies with 21 CFR 1040.10 and 1040.11 except laser de Classe 2. Conforme à 21 CFR 1040.10 et 1040.11, sauf pour les écarts for deviations pursuant to Laser Notice No. 50, dated June 24, suivant l’ Avis laser 50, 24/6/2007 2007. This can lead to persons being blinded. Safety Rules for Rangefinder Working safely with the rangefinder is Have the rangefinder repaired only through possible only when the operating and safety qualified specialist using original spare parts. information are read completely and the This ensures that the safety of the rangefinder instructions contained therin are strictly is maintained. followed. Never make warning labels on the Do not allow children to use the rangefinder Rangefinder unrecognizable. without supervision. They could unintentionally Never aim the beam at a workpiece with a blind other persons. reflective surface. Bright shiny reflective sheet Do not point the laser beam at persons or steel or similar reflective surfaces are not animals and do not look into the laser beam recommended for laser use. Reflective surfaces yourself, not even from a large distance. could direct the beam back toward the operator. Do not use the laser viewing glasses as safety Take care to recognize the accuracy and goggles. The laser viewing glasses are used for range of the device. Measurement may not improved visualization of the laser beam, but they be accurate if used beyond the rated range of do not protect against laser radiation. the device. Do not use the laser viewing glasses as sun Use of controls or adjustments or glasses or in traffic. The laser viewing glasses performance of procedures other than those do not afford complete UV protection and reduce specified herein may result in hazardous color perception. radiation exposure. The use of optical instruments with this product will increase eye hazards. Safe Operating Procedures WARNING: Be sure to read and understand all DO NOT remove or deface any warning or instructions in this manual before using this caution labels. product. Failure to follow all instructions may Removing labels increases the risk of exposure to result in hazardous radiation exposure, electric laser radiation. shock, fire, and/or bodily injury. DO NOT stare directly at the laser beam or project CAUTION: Use of controls or adjustments or the laser beam directly into the eyes of others. performance of procedures other than those Serious eye injury could result. specified in this manual, may result in hazardous DO NOT place the rangefinder in a position that radiation exposure. may cause anyone to stare into the laser beam CAUTION: The use of optical instruments with intentionally or unintentionally. Serous eye injury this product will increase eye hazard. could result. IMPORTANT: The following labels are on your DO NOT use any optical tools such as, but not rangefinder for your convenience and safety. They limited to, telescopes or transits to view the laser indicate where the laser light is emitted by the beam. Serious eye injury could result. level. ALWAYS BE AWARE of their location when ALWAYS remove the batteries when cleaning the using the level. laser light aperture to laser lens. ALWAYS: Make sure that any bystanders in the DO NOT operate the rangefinder around children vicinity of use are made aware of the dangers of or allow children to operate the rangefinder. looking directly into the rangefinder. -6- Serious eye injury could result. DO NOT leave rangefinder “on” unattended in any ALWAYS turn the rangefinder “OFF” when not in operation mode. use. Leaving the rangefinder “ON” increases the ALWAYS repair and servicing must be performed risk of someone inadvertently staring into the by a qualified repair facility. Repairs performed by laser beam. unqualified personnel could result in serious DO NOT operate the rangefinder in combustible injury. areas such as in the presence of flammable DO NOT use this rangefinder for any purpose liquids, gases or dust. other than those outlined in this manual. This ALWAYS position the rangefinder securely. Damage could result in serious injury. to the rangefinder and/or serious injury to the user DO NOT disassemble the rangefinder. There are could result if the rangefinder falls. no user serviceable parts inside. Disassembling ALWAYS use only the accessories that are the laser will void all warranties on the product. recommended by the manufacturer of your Do not modify the product in any way. Modifying rangefinder. Use of accessories that have been the rangefinder may result in hazardous laser designed for use with other rangefinders could result radiation exposure. in serious injury. Electrical Safety Procedures WARNING: Batteries can explode or leak, and DO NOT mix battery chemistries. can cause injury or fire. To reduce this risk: DISPOSE of batteries per local code. ALWAYS follow all instructions and warnings on DO NOT dispose of batteries in fire. the battery label and package. KEEP batteries out of reach of children. DO NOT short any battery terminals. REMOVE batteries if the device will not be used for DO NOT charge alkaline batteries. several months. DO NOT mix old and new batteries. Replace all of them at the same time with new batteries of the same brand and type. Environment Protection Recycle raw materials & batteries instead of disposing of waste. The unit, accessories, packaging & used batteries should be sorted for environmentally friendly recycling in accordance with the latest regulations. Functional Description INTENDED USE 12 Minus button The rangefinder is intended for measuring 13 Min. Max measurement button distances, lengths, heights, clearances and for 14 Vial level calculating areas and volumes. The rangefinder is 15 Measured-value list button suitable for interior and exterior construction 16 On/Off/Clear button site measuring. 17 Hand strap mounting post 18 Extension pin PRODUCT FEATURES 19 Laser warning label The numbering of the product features shown 20 Serial number refers to the illustration of the rangefinder on the 21 1/4" thread hole for mounting optional tripod 22 Battery compartment graphic page. 23 Locking knob of the battery compartment 1 Latch of the extension pin 24 Alignment aid 2 Continuous laser beam 25 Optical sight window (GLR825 only) 3 Function-mode button 26 Reception lens 4 Length, area and volume measurement 27 Laser beam outlet 5 Result button 28 Protective case 6 Plus button 29 Hand strap 7 Measuring and continuous measuring button 30 Laser viewing glasses* 8 Reference point button 31 Laser target plate* 9 Display 10 View finder of the optical sight (GLR825 only) 11 Display-illumination button -7- DISPLAY ELEMENTS 3 2 1 a Measured-value lines Combined indirect length measurement 2 3 b “ ERROR ” indication 1 Trapezoid measurement c Result line Timer function min Minimum measurement d Measured-value list indicator max e Measuring modes Maximum measurement Length measurement Mark-out mode Area measurement f Battery indication Volume measurement g Measurement reference point Continuous measurement h Laser switched on Multi-surface area measurement i Problem temperature indicator 2 1 Simple indirect length measurement * Optional Accessories 1 2 3 Double indirect length measurement Technical Data GLR500/825 Laser Rangefinder Article number GLR500 3601K72010 Article number GLR825 3601K72110 Dimensions 2 19/32” x 4 23/32 x 1 15/32” (66 x 120 x 37 mm) Measuring range (GLR500) A) 0.16 in ..
Recommended publications
  • Check Points for Measuring Instruments
    Catalog No. E12024 Check Points for Measuring Instruments Introduction Measurement… the word can mean many things. In the case of length measurement there are many kinds of measuring instrument and corresponding measuring methods. For efficient and accurate measurement, the proper usage of measuring tools and instruments is vital. Additionally, to ensure the long working life of those instruments, care in use and regular maintenance is important. We have put together this booklet to help anyone get the best use from a Mitutoyo measuring instrument for many years, and sincerely hope it will help you. CONVENTIONS USED IN THIS BOOKLET The following symbols are used in this booklet to help the user obtain reliable measurement data through correct instrument operation. correct incorrect CONTENTS Products Used for Maintenance of Measuring Instruments 1 Micrometers Digimatic Outside Micrometers (Coolant Proof Micrometers) 2 Outside Micrometers 3 Holtest Digimatic Holtest (Three-point Bore Micrometers) 4 Holtest (Two-point/Three-point Bore Micrometers) 5 Bore Gages Bore Gages 6 Bore Gages (Small Holes) 7 Calipers ABSOLUTE Coolant Proof Calipers 8 ABSOLUTE Digimatic Calipers 9 Dial Calipers 10 Vernier Calipers 11 ABSOLUTE Inside Calipers 12 Offset Centerline Calipers 13 Height Gages Digimatic Height Gages 14 ABSOLUTE Digimatic Height Gages 15 Vernier Height Gages 16 Dial Height Gages 17 Indicators Digimatic Indicators 18 Dial Indicators 19 Dial Test Indicators (Lever-operated Dial Indicators) 20 Thickness Gages 21 Gauge Blocks Rectangular Gauge Blocks 22 Products Used for Maintenance of Measuring Instruments Mitutoyo products Micrometer oil Maintenance kit for gauge blocks Lubrication and rust-prevention oil Maintenance kit for gauge Order No.207000 blocks includes all the necessary maintenance tools for removing burrs and contamination, and for applying anti-corrosion treatment after use, etc.
    [Show full text]
  • AR4000 Laser Rangefinder Users Manual
    AccuRange 4000™ Laser Rangefinder AccuRange™ Line Scanner User’s Manual LLL004001 – Rev. 2.7 For use with AR4000™ and Line Scanner September 5, 2008 Acuity A product of Schmitt Industries, Inc. 2765 NW Nicolai St. Portland, OR 97210 www.acuitylaser.com Limited Use License Agreement YOU SHOULD CAREFULLY READ THE FOLLOWING TERMS AND CONDITIONS BEFORE OPENING THE PACKAGE CONTAINING THE COMPUTER SOFTWARE AND HARDWARE LICENSED HEREUNDER. CONNECTING POWER TO THE MICROPROCESSOR CONTROL UNIT INDICATES YOUR ACCEPTANCE OF THESE TERMS AND CONDITIONS. IF YOU DO NOT AGREE WITH THEM, YOU SHOULD PROMPTLY RETURN THE UNIT WITH POWER SEAL INTACT TO THE PERSON FROM WHOM IT WAS PURCHASED WITHIN FIFTEEN DAYS FROM DATE OF PURCHASE AND YOUR MONEY WILL BE REFUNDED BY THAT PERSON. IF THE PERSON FROM WHOM YOU PURCHASED THIS PRODUCT FAILS TO REFUND YOUR MONEY, CONTACT SCHMITT INDUSTRIES INCORPORATED IMMEDIATELY AT THE ADDRESS SET OUT BELOW. Schmitt Industries Incorporated provides the hardware and computer software program contained in the microprocessor control unit, and licenses the use of the product to you. You assume responsibility for the selection of the product suited to achieve your intended results, and for the installation, use and results obtained. Upon initial usage of the product your purchase price shall be considered a nonrefundable license fee unless prior written waivers are obtained from Schmitt Industries incorporated. LICENSE a. You are granted a personal, nontransferable and non-exclusive license to use the hardware and software in this Agreement. Title and ownership of the hardware and software and documentation remain in Schmitt Industries, Incorporated; b. the hardware and software may be used by you only on a single installation; c.
    [Show full text]
  • Intro to Measurement Uncertainty 2011
    Measurement Uncertainty and Significant Figures There is no such thing as a perfect measurement. Even doing something as simple as measuring the length of a pencil with a ruler is subject to limitations that can affect how close your measurement is to its true value. For example, you need to consider the clarity and accuracy of the scale on the ruler. What is the smallest subdivision of the ruler scale? How thick are the black lines that indicate centimeters and millimeters? Such ideas are important in understanding the limitations of use of a ruler, just as with any measuring device. The degree to which a measured quantity compares to the true value of the measurement describes the accuracy of the measurement. Most measuring instruments you will use in physics lab are quite accurate when used properly. However, even when an instrument is used properly, it is quite normal for different people to get slightly different values when measuring the same quantity. When using a ruler, perception of when an object is best lined up against the ruler scale may vary from person to person. Sometimes a measurement must be taken under less than ideal conditions, such as at an awkward angle or against a rough surface. As a result, if the measurement is repeated by different people (or even by the same person) the measured value can vary slightly. The degree to which repeated measurements of the same quantity differ describes the precision of the measurement. Because of limitations both in the accuracy and precision of measurements, you can never expect to be able to make an exact measurement.
    [Show full text]
  • The Gage Block Handbook
    AlllQM bSflim PUBUCATIONS NIST Monograph 180 The Gage Block Handbook Ted Doiron and John S. Beers United States Department of Commerce Technology Administration NET National Institute of Standards and Technology The National Institute of Standards and Technology was established in 1988 by Congress to "assist industry in the development of technology . needed to improve product quality, to modernize manufacturing processes, to ensure product reliability . and to facilitate rapid commercialization ... of products based on new scientific discoveries." NIST, originally founded as the National Bureau of Standards in 1901, works to strengthen U.S. industry's competitiveness; advance science and engineering; and improve public health, safety, and the environment. One of the agency's basic functions is to develop, maintain, and retain custody of the national standards of measurement, and provide the means and methods for comparing standards used in science, engineering, manufacturing, commerce, industry, and education with the standards adopted or recognized by the Federal Government. As an agency of the U.S. Commerce Department's Technology Administration, NIST conducts basic and applied research in the physical sciences and engineering, and develops measurement techniques, test methods, standards, and related services. The Institute does generic and precompetitive work on new and advanced technologies. NIST's research facilities are located at Gaithersburg, MD 20899, and at Boulder, CO 80303. Major technical operating units and their principal
    [Show full text]
  • Surftest SJ-400
    Form Measurement Surftest SJ-400 Bulletin No. 2013 Aurora, Illinois (Corporate Headquarters) (630) 978-5385 Westford, Massachusetts (978) 692-8765 Portable Surface Roughness Tester Huntersville, North Carolina (704) 875-8332 Mason, Ohio (513) 754-0709 Plymouth, Michigan (734) 459-2810 City of Industry, California (626) 961-9661 Kirkland, Washington (408) 396-4428 Surftest SJ-400 Series Revolutionary New Portable Surface Roughness Testers Make Their Debut Long-awaited performance and functionality are here: compact design, skidless and high-accuracy roughness measurements, multi-functionality and ease of operation. Requirement Requirement High-accuracy1 measurements with 3 Cylinder surface roughness measurements with a hand-held tester a hand-held tester A wide range, high-resolution detector and an ultra-straight drive The skidless measurement and R-surface compensation functions unit provide class-leading accuracy. make it possible to evaluate cylinder surface roughness. Detector Measuring range: 800µm Resolution: 0.000125µm (on 8µm range) Drive unit Straightness/traverse length SJ-401: 0.3µm/.98"(25mm) SJ-402: 0.5µm/1.96"(50mm) SJ-401 SJ-402 SJ-401 Requirement Requirement Roughness parameters2 that conform to international standards The SJ-400 Series can evaluate 36 kinds of roughness parameters conforming to the latest ISO, DIN, and ANSI standards, as well as to JIS standards (1994/1982). 4 Measurement/evaluation of stepped features and straightness Ultra-fine steps, straightness and waviness are easily measured by switching to skidless measurement mode. The ruler function enables simpler surface feature evaluation on the LCD monitor. 2 3 Requirement Measurement Applications R-surface 5 measurement Advanced data processing with extended analysis The SJ-400 Series allows data processing identical to that in the high-end class.
    [Show full text]
  • Length Scale Measurement Procedures at the National Bureau of 1 Standards
    NEW NIST PUBLICATION June 12, 1989 NBSIR 87-3625 Length Scale Measurement Procedures at the National Bureau of 1 Standards John S. Beers, Guest Worker U.S. DEPARTMENT OF COMMERCE National Bureau of Standards National Engineering Laboratory Precision Engineering Division Gaithersburg, MD 20899 September 1987 U.S. DEPARTMENT OF COMMERCE NBSIR 87-3625 LENGTH SCALE MEASUREMENT PROCEDURES AT THE NATIONAL BUREAU OF STANDARDS John S. Beers, Guest Worker U.S. DEPARTMENT OF COMMERCE National Bureau of Standards National Engineering Laboratory Precision Engineering Division Gaithersburg, MD 20899 September 1987 U.S. DEPARTMENT OF COMMERCE, Clarence J. Brown, Acting Secretary NATIONAL BUREAU OF STANDARDS, Ernest Ambler, Director LENGTH SCALE MEASUREMENT PROCEDURES AT NBS CONTENTS Page No Introduction 1 1.1 Purpose 1 1.2 Line scales of length 1 1.3 Line scale calibration and measurement assurance at NBS 2 The NBS Line Scale Interferometer 2 2.1 Evolution of the instrument 2 2.2 Original design and operation 3 2.3 Present form and operation 8 2.3.1 Microscope system electronics 8 2.3.2 Interferometer 9 2.3.3 Computer control and automation 11 2.4 Environmental measurements 11 2.4.1 Temperature measurement and control 13 2.4.2 Atmospheric pressure measurement 15 2.4.3 Water vapor measurement and control 15 2.5 Length computations 15 2.5.1 Fringe multiplier 16 2.5.2 Analysis of redundant measurements 17 3. Measurement procedure 18 Planning and preparation 18 Evaluation of the scale 18 Calibration plan 19 Comparator preparation 20 Scale preparation,
    [Show full text]
  • Core Sampling for Plant Belowground Biomass Date: 02/17/2017
    Title: TOS Protocol and Procedure: Core Sampling for Plant Belowground Biomass Date: 02/17/2017 NEON Doc. #: NEON.DOC.014038 Author: C. Meier Revision: E TOS PROTOCOL AND PROCEDURE: CORE SAMPLING FOR PLANT BELOWGROUND BIOMASS PREPARED BY ORGANIZATION DATE Courtney Meier SCI 03/25/2013 APPROVALS ORGANIZATION APPROVAL DATE Andrea Thorpe SCI 01/27/2017 Mike Stewart SYS 02/15/2017 RELEASED BY ORGANIZATION RELEASE DATE Judy Salazar CM 02/17/2017 See configuration management system for approval history. The National Ecological Observatory Network is a project solely funded by the National Science Foundation and managed under cooperative agreement by Battelle. Any opinions, findings, and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of the National Science Foundation. Template NEON.DOC.050006 Rev F Title: TOS Protocol and Procedure: Core Sampling for Plant Belowground Biomass Date: 02/17/2017 NEON Doc. #: NEON.DOC.014038 Author: C. Meier Revision: E Change Record REVISION DATE ECO # DESCRIPTION OF CHANGE A 03/25/2011 ECO-00148 Initial release Production release, template change, method B 01/20/2015 ECO-02273 improvements C 02/26/2015 ECO-02702 Migration to new protocol template Major changes to protocol include: All SOPs now implemented together every time protocol is executed, previously SOP D implemented 1X per site Timing information updated, and preservation of cores prior to core processing eliminated. Equipment list updates for lab work SOP C.1 sieving methods updated based on megapit sampling experience Roots from 2 cores within a clipCell are now pooled after D 1/28/2016 ECO-03547 weighing takes place and prior to grinding for chemical analysis / archive.
    [Show full text]
  • There Is a Difference Between 10 Years Experience, and Six Months of Experience Repeated 20 Times
    CUT TIPS FROM THE CANOPY There is a difference between 10 years experience, and six months of experience repeated 20 times. That is quite a powerful concept that I was fortunate enough to learn from professional arborist, trainer, author, and all-around great guy, Tony Tresselt. The concept has stuck with me, and I find its value in the industry and life as well. If we only repeat what we learned in the first six months on a job, and do not take the initiative to continue our learning, then why should we expect to become better at what we do? We should always be looking to advance our knowledge and put it into practice in the field. Identifying opportunities and searching for a solution should be part of our thought process. Nothing wrong with using what we learned when first starting our career. After all, you have to start somewhere, but we should aim to venture out and look to further our knowledge, and not rely only on our initial training. It is easy to look at rigging and climbing gear and get lost in the multitude of new products and techniques, but how often do we look at new methods or systems for cutting and felling? A lot of injuries and fatalities occur every year, which are directly caused by some act of cutting. These casualties occur from both cutting in the tree and on the ground. Looking at climbing systems or rigging systems, we are quick to explore other options and methods because we see distinct advantages.
    [Show full text]
  • Quick Guide to Precision Measuring Instruments
    E4329 Quick Guide to Precision Measuring Instruments Coordinate Measuring Machines Vision Measuring Systems Form Measurement Optical Measuring Sensor Systems Test Equipment and Seismometers Digital Scale and DRO Systems Small Tool Instruments and Data Management Quick Guide to Precision Measuring Instruments Quick Guide to Precision Measuring Instruments 2 CONTENTS Meaning of Symbols 4 Conformance to CE Marking 5 Micrometers 6 Micrometer Heads 10 Internal Micrometers 14 Calipers 16 Height Gages 18 Dial Indicators/Dial Test Indicators 20 Gauge Blocks 24 Laser Scan Micrometers and Laser Indicators 26 Linear Gages 28 Linear Scales 30 Profile Projectors 32 Microscopes 34 Vision Measuring Machines 36 Surftest (Surface Roughness Testers) 38 Contracer (Contour Measuring Instruments) 40 Roundtest (Roundness Measuring Instruments) 42 Hardness Testing Machines 44 Vibration Measuring Instruments 46 Seismic Observation Equipment 48 Coordinate Measuring Machines 50 3 Quick Guide to Precision Measuring Instruments Quick Guide to Precision Measuring Instruments Meaning of Symbols ABSOLUTE Linear Encoder Mitutoyo's technology has realized the absolute position method (absolute method). With this method, you do not have to reset the system to zero after turning it off and then turning it on. The position information recorded on the scale is read every time. The following three types of absolute encoders are available: electrostatic capacitance model, electromagnetic induction model and model combining the electrostatic capacitance and optical methods. These encoders are widely used in a variety of measuring instruments as the length measuring system that can generate highly reliable measurement data. Advantages: 1. No count error occurs even if you move the slider or spindle extremely rapidly. 2. You do not have to reset the system to zero when turning on the system after turning it off*1.
    [Show full text]
  • Part Ii: Procedures and Equipment for Weighing, Measuring and Recording Anthropometric Data
    PART II: PROCEDURES AND EQUIPMENT FOR WEIGHING, MEASURING AND RECORDING ANTHROPOMETRIC DATA In order to accurately reflect health status, measurements must be taken carefully using standardized techniques. The results must be recorded accurately and compared with the appropriate references. Measurements do not need to be done twice, if the one measurement is done correctly, using proper equipment and technique. If there is any doubt about the accuracy of a measurement, it should be repeated. Measuring Recumbent Length of Infants and Young Children Until age 2, children must be measured in the recumbent position. Between 2 and 3 years of age the CPA (or individual measuring the child) must decide whether a recumbent or standing measurement is most appropriate. If the child is <32”, a recumbent measurement must be used, because the charts based on standing height apply only to heights > 32”. For children 2 to 3 years of age, taller than 32”, the best guideline is to think about the physical abilities of the child. Generally, if a child can stand unassisted and follow directions for proper positioning, a standing measure should be taken. If the child cannot stand straight, a recumbent length should be measured. birth to 24 months………measure recumbent length . between 2 and 3 years of age: o if < 32”……………….measure recumbent length o if ≥ 32” if child can stand unassisted in proper position, measure standing if child cannot stand properly, measure recumbent length . over 3 years of age……………..measure standing height A. Equipment: Use a recumbent measuring board with a fixed headpiece and sliding foot piece that are both perpendicular/upright (form a 90-degree angle) to the measurement surface.
    [Show full text]
  • I Introduction to Measurement and Data Analysis
    I Introduction to Measurement and Data Analysis Introduction to Measurement In physics lab the activity in which you will most frequently be engaged is measuring things. Using a wide variety of measuring instruments you will measure times, temperatures, masses, forces, speeds, frequencies, energies, and many more physical quantities. Your tools will span a range of technologies from the simple (such as a ruler) to the complex (perhaps a digital computer). Certainly it would be worthwhile to devote a little time and thought to some of the details of \measuring things" that may have not yet occurred to you. True Value - How Tall? At first thought you might suppose that the goal of measurement is a very straightforward one: find the true value of the thing being measured. Alas, things are seldom as simple as we would like. Consider the following \case study." Suppose you wished to measure how your lab partner's height. One way might be to simply look at him or her and estimate, \Oh, about five-nine," meaning five feet, nine inches tall. Of course you couldn't be sure that five-eight or five-ten, or even five-eleven might be a better estimate. In other words, your measurement (estimate) is uncertain by some amount, perhaps an inch or two either way. The \true value" lies somewhere within a range of uncertainty and one way to express this notion is to say that your partner's height is five feet, nine inches plus or minus two inches or 69 ± 2 inches. It should begin to be clear that at least one of the goals of measurement is to reduce the uncertainty to as small an amount as is feasible and useful.
    [Show full text]
  • Comparison of Internal and External Threads Pitch Diameter Measurement by Using Conventional Methods and CMM’S
    19th International Congress of Metrology, 09001 (2019) https://doi.org/10.1051/metrology/201909001 Comparison of internal and external threads pitch diameter measurement by using conventional methods and CMM’s İ. Ahmet Yüksel1*, T. Oytun Kılınç1, K. Berk Sönmez1, and Sinem Ön Aktan1 1Department of Laboratories and Calibration Management, Roketsan Missiles Industries Inc., 06780 Ankara, Turkey Abstract. Threads are very frequent and critical connection methods of components to build final products as per desired technical requirements. As it is used for very wide numbers of applications and industries, tolerances and thread structure differ as per requirements of applied areas. After theoretical decision of threaded parts, one hard task is to manufacture this thread as required. Correct flank angle, pitch diameter, pitch, height, major/minor diameters shall be obtained to receive desired mechanical connection properties. So as a result of all importance of threaded connection, it is also important to control thread properties. In this study it is aimed to show that as a result of significant development on sensor and probing technology, Coordinate Measuring Machines (CMMs) are good alternatives of conventional methods by considering accuracy, time requirement, setup requirements, and ease of application. In order to evaluate competence of regular bridge type CMMs regarding simple pitch diameter measurement, results of pitch diameter from symmetric thread with 30º flank angles will be taken by 1D length measurement device and bridge type CMM to compare. Comparison of conventional methods and CMM’s result shows that CMMs also provide accurate and precise results and can be used for calibration of gages as an alternative method with a number of advantages which are shown by this study.
    [Show full text]