Ultimate™ U39 Freestanding Gas Stove Installation Manual
Total Page:16
File Type:pdf, Size:1020Kb
Owners & Ultimate™ U39 Freestanding Gas Stove Installation Manual www.regency-fire.com MODELS: U39-NG12 Natural Gas U39-LP12 Propane Warning Fire or Explosion Hazard Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch: do not use any phone in your building. Leave the building immediately. • Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. 04.05.18 -- updated log instructions Tested by: Certified to/Certifié pour: CSA 2.17-2017 Installer: Please complete the details on the back cover ANSI Z21.88-2017 and leave this manual with the homeowner. CSA 2.33-2017 Homeowner: Please keep these instructions for future reference. 920-135c FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 08.17.21 REGENCY® ULTIMATE Direct Vent Freestanding Gas Stove To the New Owner: Congratulations! You are the owner of a state-of-the-art ULTIMATE Direct Vent Gas Stove by FPI Fireplace Products International Ltd. The Regency® Gas Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a woodstove, at the flick of a switch. The models U39-NG12, and U39-LP12 of this series has been approved by Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your ULTIMATE Direct Vent Freestanding Gas Stove. This appliance may only be installed in an after- market permanently located, manufactured (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless U38-39 Video a certified kit is used. 2 | Regency® U39-12 ULTIMATE™ Freestanding Gas Stove table of contents Dimensions ..................................................................4 Aeration Adjustment ....................................................30 On Demand Pilot Light ................................................30 Copy of Safety Label for U39 Gas Stove ...................5 Log Set Installation ......................................................31 Log Set Installation ......................................................33 Installation Wiring Diagrams .........................................................37 Gas Installation Checklist ..............................................7 Optional Wall Thermostat ...........................................38 Before You Start .............................................................9 DC Spark Igniter Battery Install ...................................38 Important Message ......................................................10 Final Check ..................................................................38 Specifications ..............................................................10 First Fire ......................................................................39 Information For Mobile/Manufactured Homes After First Sale .............................................................10 Operating Instructions General Safety Information ..........................................11 Installation Checklist ....................................................11 First Fire ......................................................................39 Clearances To Combustibles .......................................11 Operating Instructions .................................................39 Manufactured Mobile Home Additional Requirements 12 Lighting Procedure ......................................................39 Locating Your Ultimate Gas Stove .............................12 Shutdown Procedure ...................................................39 Louver Installation .......................................................12 Copy of Lighting Plate Instructions ..............................40 Combustion And Ventilation Air ...................................12 Automatic Convection Fan Operation ..........................41 Safety Screen Installation ............................................12 Adjusting Flame Height ...............................................41 Venting Introduction .....................................................12 Normal Operating Sounds of Gas Appliances .............41 Exterior Vent Terminal Locations .................................13 Proflame GTMF System Operating Instructions ..........42 4” x 6-5/8” Rigid Pipe Cross Reference Chart .............14 Rigid Pipe Venting Systems .........................................16 Maintenance Installation Precautions ...............................................17 Maintenance Instructions ............................................45 Safety Precautions of the Installer ...............................17 General Vent Maintenance ..........................................45 Rigid Pipe Venting Arrangements ................................18 Log Replacement ........................................................46 DV Stove Horizontal Vent Kit Installation .....................20 Door Gasket ...............................................................46 Dura-Vent Termination Kit ............................................22 Latch Adjustment .........................................................46 Dura-Vent Venting Components ..................................22 Glass Replacement .....................................................46 Dura-Vent Horizontal Terminations ..............................23 Panel Glass Replacement ...........................................46 Dura-Vent Vertical Terminations...................................24 Fan Maintenance .........................................................47 Cathedral Ceilings .......................................................25 DC Sparker Battery Replacement ...............................47 Converting a Class-A Metal Chimney to a Valve Replacement ......................................................48 Direct Vent System ......................................................26 Gas Maintenance ........................................................49 System Data ................................................................27 Gas Connection ...........................................................27 Parts High Elevation ..............................................................27 Main Assembly ............................................................50 Conversion from NG to LP...........................................28 Burner & Log Assembly ...............................................51 Conversion to Lower BTU Rating ................................29 Door Assembly ............................................................52 Gas Pipe Pressure Testing ..........................................29 SIT 829 Valve Description ...........................................30 Warranty Warranty ......................................................................54 Regency® U39-12 ULTIMATE™ Freestanding Gas Stove | 3 dimensions " 1 4 4 (108mm) 13 916" (250mm) ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY. ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS. 4 | Regency® U39-12 ULTIMATE™ Freestanding Gas Stove safety decal This is a copy of the label that accompanies each NOTE: Regency® units are constantly being ULTIMATE Direct Vent Freestanding Gas Stove. We improved. Check the label on the unit and if there is have printed a copy of the contents here for your a difference, the label on the unit is the correct one. review. The safety label is located on the inside of the drop down pedestal door. Copy of Safety Label for U39 Gas Stove Duplicate serial # 532 Listed: VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION DO NOT REMOVE THIS LABEL / Certifi ed to/Certifi é : ANSI Z21.88-2017 • CSA 2.33-2017 / CSA 2.17-2017 NE PAS ENLEVER CETTE ÉTIQUETTE 532 MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE Refer to Intertek's Directory of Building Products for detailed information. Serial No./No de série Pour plus de détails, se reporter au Répertoire des produits de construction de Intertek. C# 4001172 FACTORY EQUIPPED FOR NATURAL GAS: Model U39-NG12 APPAREIL FONCTIONNANT AU GAZ NATUREL : Modèle U39-NG12 Minimum Clearances to Combustibles Pression d’alimentation minimale Dégagements minimaux aux matériaux combustibles U M Minimum supply pressure 5" WC/C.E. (1.25kPa) 3 o Manifold pressure High 3.5" WC/C.E. (0.87kPa) Pression manifold élevée 9 A 7-1/2" /190mm d - Pression manifold basse e N Manifold pressure Low 1.6" WC/C.E. (0.40kPa) B 6" /150mm l G / Fonctionnant à une altitude entre 0 et 2000 pi : M Model U39-NG12: Factory Equipped for Altitude 0-2000 ft. E 2" /50mm 1 o 2 d Orifi ce size #32 DMS Dimensions de l’orifi ce Min. Ceiling Height from top of unit / Min. Plafond è Hauteur depuis le haut de l'appareil: l Altitude 0-2000 ft/pi (0-610) e Altitude 36" / 914 mm : Maximum Input 38,000 Btu/h (11.1Kwh) Débit calorifi que maximal