High Accuracy Modbus Energy Meter Features
Total Page:16
File Type:pdf, Size:1020Kb
pMon® PM-3133P DIN Rail Modbus Power Meter High Accuracy Modbus Energy Meter Features High accuracy power meter pMon® PM-3133P is an advanced smart meter designed to measure and calibrated to achieve 0.5% accuracy report True RMS measurement data for power quality, energy consumption or better. and demand analysis.The PM-3000 series meters can be applied to both True RMS measurements, including the low voltage primary side and/or medium/high voltage secondary side, kW, kVAr, kVA, Power Factor and THD. operating over a wide range of input voltages from 10 to 500 VAC at 50 or 60Hz. In addition to monitoring, there are two relay output channels Modbus RTU/TCP support and options controlled via Modbus protocol for load control, demand management or for RS-485 Serial communication or exception notification. Ethernet to suit individual needs. Utilising its low profile form factor, PM-3000 series energy meter can be Safe extra-low voltage, split core installed neatly into existing distribution board or wiring panel. Multiple current transformer for safe and easy PM-3000 series meters can be connected and managed by pMon® PMC-5151 installation. Intelligent Gateway using daisy chain scheme for device management, data Dual relay switch for equipment logging, web-based reporting and high level application integration with control and demand management. pMon® Dashboard, DCIM or SCADA/BMS. pMon Dashboard Application Electrical Room CRAC Units PM-3133 PM-3133 PM-3133 DCIM Server Room/ Data Hall PMC-5151 Operation/Control Room SCADA/BMS PM-3133 PM-3133 Cooling Tower PM-3133 Air Handling Units Chiller Plant pMon® PM-3133P DIN Rail Modbus Power Meter Dimensions Specifications Model PM-3133P PM-3133P-MTCP AC Power Measurement Wiring 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT Top 100 Input Voltage 10 ~ 500V 90 33 Input Current pMon® approved Current Transformer with 37.2 333mV Secondary Output 35.6 127 110 Input Frequency 50/60 Hz 37.2 Accuracy Calibrated to 0.5% accuracy or better Power Parameter True RMS Voltage (Vrms), True RMS Current (Irms), Active Power 6.5 Left Side Front Right Side View Rear View Measurement (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy Units: mm (kVARh), Power Factor (PF) Data Update Rate 1 Second Communication Bottom RS-485 Protocol Modbus-RTU — Baud rate 9600, 19200 (default), 38400, — RoHS 115200 DIP Switch Selectable Ordering Information Data format 8-N-1 — Isolation 2500 VDC — PM-3133P-EZ Ethernet Protocol — Modbus TCP pMon 3-Phase 3 CTs RS-485 Modbus RTU CAN Bus Protocol — — Power Meter with 2 x Relay Output Baud rate — — Isolation — — PM-3133P-MTCP-EZ Alarm Output pMon 3-Phase 3 CTs Ethernet Modbus TCP Power Meter with 2 x Relay Output Power Relay Form A (Normal Open) x 2; Relay Contact Voltage Range: 5A @ 250 VAC (47 ~ 63Hz), 5A @ 30 VDC Power Related Products Input Range +12 ~ 48 VDC PMC-5151-EZ CR Power Consumption 4W pMon Power Meter Concentrator (RoHS) Mechanical MDR-100-24-EZ Casing Plastic 24 VDC 100W DIN Rail Power Supply Dimensions (W x L x H) 127mm x 105mm x 33mm PMON-24P-WKIT Module Installation DIN-Rail Mounting 24-pole Wiring Kit (incl. terminal blocks CT Installation Split Core, Clip-On and pre-cut hook-up wires) Environment Operating Temperature -10 ~ +70ºC Storage Temperature -25 ~ +80ºC Ambient Relative Humidity 10% ~ 90% RH, Non-condensing T +61 (02) 9690 2852 F +61 (02) 9698 6952 [email protected] www.idcsolutions.com.au Data Centre, Power Monitoring & Air Flow Management Specialists. ©IDC Solutions Pty Ltd. March 2015 / 7167.