Hoffmann Architects, Inc. G000
Total Page:16
File Type:pdf, Size:1020Kb
DRAWINGS G000 COVER SHEET G001 SITE PLAN, ABBREVIATIONS, SYMBOLS, AND NOTES A101 FLOOR PLANS A201 EAST AND SOUTH ELEVATIONS A202 WEST AND NORTH ELEVATIONS FACADE REPAIRS A501 DETAILS 61 DURANT TERRACE MIDDLETOWN, CT CITY OF MIDDLETOWN 245 deKOVEN DRIVE 06457 HOFFMANN ARCHITECTS, INC. 2711 Jefferson Davis Highway, Suite 333 2321 Whitney Avenue, 2 nd Floor 1040 Avenue of the Americas, Suite 14C Arlington, VA Hamden, Connecticut New York, NY SEAL 22202 06518 10018 PROJECT NO. 219068 17 SEPTEMBER 2020 G000 COPYRIGHT HOFFMANN ARCHITECTS, INC. 2020 DURANT TERRACE (ONE WAY) FACADE SIDEWALK SIDEWALK REPAIRS MAIN DRIVEWAY ENTRANCE CANOPY 61 DURANT TERRACE MAIN ENTRANCE MIDDLETOWN, CT NORTH PARKING LOT LAKE STREET EXISTING BUILDING ENTRANCE/ ENTRANCE/ 61 DURANT TERRACE EXIT EXIT BUILDING ADDRESS: SIDEWALK 61 DURANT TERRACE DUMPSTERS SOUTH PARKING LOT MIDDLETOWN, CT 06457 DURANT STREET ENTRANCE/ EXISTING TERRACE EXIT SIDEWALK CLIENT / OWNER: CITY OF MIDDLETOWN EXISTING 245 deKOVEN DRIVE PERGOLA MIDDLETOWN, CT 01109 SITE PLAN EXISTING SCALE: BOCCE COURT BIRDSEY AVENUE (ONE WAY) GENERAL NOTES: DRAFTING SYMBOLS: SIDEWALK 1. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND CONDITIONS OF THE SITE AND/OR BUILDING. 2. THE CONTRACTOR SHALL, UNLESS OTHERWISE PROVIDED IN THE NORTH ARROW CONTRACT DOCUMENTS, SECURE AND PAY FOR THE REQUIRED CONSTRUCTION PERMIT(S), FEES, LICENSES AND INSPECTIONS NECESSARY FOR THE PROPER EXECUTION OF THE WORK. 3. COORDINATION OF ALL WORK UNDER THIS CONTRACT SHALL BE MAINTAINED TO ENSURE THE QUALITY AND TIMELY COMPLETION OF FLOOR ELEVATION MARK THE WORK/PROJECT. ELEVATION NOTICE: 4. THE CONTRACTOR SHALL PERFORM ALL CUTTING AND PATCHING REQUIRED TO COMPLETE THE WORK OR TO MAKE ITS PARTS FIT DO NOT SCALE DRAWINGS. TOGETHER PROPERLY WITHOUT COMPROMISING THE QUALITY OF CONTRACTOR IS RESPONSIBLE FOR THE WORK. VERIFYING ALL DIMENSIONS AND DETAILS. REPORT ANY DISCREPANCIES 5. PRIOR TO BEGINNING WORK AT SITE, WHERE POSSIBLE, AND COLUMN LINE TO THE ARCHITECT FOR RESOLUTION. THROUGHOUT THE COURSE OF THE WORK, INSPECT AND VERIFY THE LOCATION AND CONDITION OF EVERY ITEM AFFECTED BY THE WORK UNDER THIS CONTRACT AND REPORT DISCREPANCIES TO ARCHITECT BEFORE DOING WORK . DRAWING TITLES: 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY CODE DATA: BUILDING DEPARTMENT NOTES: ABBREVIATIONS: BRACING AND PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, COLLAPSE, DISTORTIONS, AND OFF X DRAWING NAME ALIGNMENTS ACCORDING TO CODES AND STANDARDS OF GOOD SCALE: 2018 CONNECTICUT STATE BUILDING CODE: THE FOLLOWING NOTES SHALL APPLY THROUGHOUT: A.F.F. ABOVE FINISHED FLOOR IN INCH PRACTICE. AXXX AHU AIR HANDLING UNIT HOFFMANN ARCHITECTS, INC. THRESHOLD BUILDING LIMITS: NOT APPLICABLE - REPAIRS TO EXISTING 1. WORK SHALL BE EXECUTED IN FULL COMPLIANCE WITH THE APPLICABLE INSUL. INSULATION 7. PRIOR TO BEGINNING WORK AT SITE, INSPECT THE EXISTING 2321 WHITNEY AVENUE PROVISIONS OF ALL LAWS, BY-LAWS, STATUTES, ORDINANCES, CODES, RULES, APPROX. APPROXIMATELY MAX. MAXIMUM HAMDEN, CONNECTICUT 06518 BUILDING AND DETERMINE THE EXTENT OF EXISTING ITEMS WHICH USE GROUP CLASSIFICATIONS: A-2, B REGULATIONS AND LAWFUL ORDERS OF PUBLIC AUTHORITIES BEARING ON THE (203) 239-6660 MUST BE REMOVED AND REINSTALLED IN ORDER TO PERFORM THE DRAWING NAME PERFORMANCE AND EXECUTION OF THE WORK. THE CONTRACTOR SHALL ARCH. ARCHITECTURAL MIN. MINIMUM WORK UNDER THIS CONTRACT. SCALE: CONSTRUCTION TYPE: EXISTING, TYPE III A PROMPTLY NOTIFY THE OWNER OF ANY PORTIONS OF THE WORK, IN THE AT EXISTING LIGHTNING MISC. MISCELLANEOUS CONTRACT DOCUMENTS THAT ARE AT VARIANCE WITH THE ABOVE. 8. ALL WORK IS TO CONFORM TO ALL APPLICABLE REQUIREMENTS OF TOTAL OCCUPANT LOAD: EXISTING, NOT AFFECTED BY WORK AIR TERMINAL MECH. MECHANICAL SEAL: LOCAL GOVERNING CODES, CT DEPT. OF LABOR, INDUSTRIAL LABOR ELEVATION REFERENCE: 2. THE CONSTRUCTION CLASSIFICATION OF THE BUILDING SHALL REMAIN CODE, HEALTH CODE, FIRE DEPARTMENT REGULATIONS, NBFU AND CAPACITY OF EXITS: EXISTING, NOT AFFECTED BY WORK UNCHANGED. BLDG. BUILDING N NORTH UTILITY CODES, OSHA CODES AND THE MASSACHUSETTS STATE BUILDING CODE. FIRE RESISTANCE RATINGS: EXISTING, NOT AFFECTED BY WORK 3. NO CHANGE TO EXISTING BUILDING OCCUPANCY, USE, OR MEANS OF EGRESS. BR BRICK REPAIR N.I.C. NOT IN CONTRACT X DRAWING NUMBER NO. NUMBER 9. DRAWINGS ARE NOT TO BE SCALED. ALL DIMENSIONS AND AXXX SHEET NUMBER FIRE PROTECTION SYSTEM: EXISTING, NOT AFFECTED BY WORK 4. ALL PRE-EXISTING BUILDINGS CLEARANCES AND SETBACKS FROM THE C.J. CONTROL JOINT CONDITIONS SHOWN AND ASSUMED ON THE DRAWINGS MUST BE N.T.S. NOT TO SCALE PROPERTY LINES SHALL BE MAINTAINED. CL CENTER LINE VERIFIED AT THE SITE BY THE CONTRACTOR BEFORE ORDERING ANY CLASSIFICATION OF OCCUPANCY: EXISTING BUSINESS MATERIAL OR DOING ANY WORK. ANY DISCREPANCIES IN THE 5. THE OWNER WILL BE RESPONSIBLE FOR FILING WITH, OBTAINING APPROVAL CMU CEMENT MASONRY UNIT O.C. ON CENTER DRAWINGS AND SPECIFICATIONS SHALL BE REPORTED TO THE DETAIL REFERENCES: NOTIFICATION ALARMS: EXISTING TO REMAIN UNCHANGED FROM, PAY ALL RELATED FEES, AND OBTAINING ALL THE NECESSARY CONT. CONTINUOUS ARCHITECT. NO CHANGE IN DRAWINGS OR SPECIFICATIONS IS CONSTRUCTION PERMITS FROM THE DEPARTMENT OF BUILDINGS AND COMPLY O.D. OUTSIDE DIAMETER PERMISSIBLE WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. DETECTION SYSTEM: EXISTING TO REMAIN UNCHANGED WITH THE DEPARTMENT OF BUILDINGS REQUIREMENTS FOR PUBLIC PROTECTION. OPP. OPPOSITE X DRAWING NUMBER DIA. DIAMETER 10. ALL WORK ON THESE DRAWINGS SHALL BE CONSIDERED NEW WORK AXXX SHEET NUMBER EXTINGUISHING SYSTEM: EXISTING TO REMAIN UNCHANGED PL. PLATE DRAWN BY: ELK WHETHER STATED OR NOT EXCEPT WHERE SPECIFICALLY NOTED AS DL DRAIN LEADER PP PITCH POCKET CHECKED BY: LEK/RMS "EXISTING". DN DOWN DATE: 9/17/20 PT. PRESSURE TREATED 11. DETAILS NOT SHOWN OR SPECIFIED, BUT NECESSARY FOR PROPER X DRAWING NUMBER DS DOWN SPOUT SCALE: AS NOTED AND ACCEPTABLE CONSTRUCTION, INSTALLATION OR OPERATION AXXX SHEET NUMBER R RADIUS OF ANY PART OF THE WORK AS DETERMINED BY THE ARCHITECT, DWG. DRAWING SHALL BE INCLUDED IN THE WORK THE SAME AS IF HEREIN R.D. ROOF DRAIN SPECIFIED OR INDICATED, AT NO ADDITIONAL COST TO THE OWNER. EF EXISTING EXHAUST FAN REQ'D. REQUIRED E.J. EXPANSION JOINT 12. DURING CONSTRUCTION, TEMPORARY BAFFLES TO SEAL CONST. CODE INFORMATION: SAFETY NOTES: R.L. RAIN LEADER SITE PLAN, OPENINGS TO PREVENT DUST, DIRT AND ODORS FROM FILTERING EL. ELEVATION INTO OCCUPIED AREAS ARE TO BE PROVIDED BY CONTRACTOR. RTU ROOFTOP UNIT 2018 CONNECTICUT STATE BUILDING CODE THE FOLLOWING SHALL APPLY THROUGHOUT: EQ. EQUAL ABREVIATIONS, 13. CONTRACTOR SHALL RELOCATE/MODIFY AND PATCH ANY EXISTING EXIST. EXISTING S SCUPPER ITEMS INTERFERING WITH THE INSTALLATION OF NEW WORK, INTERNATIONAL CODE COUNCIL (ICC) 1. CONSTRUCTION OPERATION WILL NOT BLOCK HALLWAYS OR MEANS OF EGRESS FOR SYMBOLS, AND DRAWING NUMBER SAN SANITARY WHETHER SHOWN OR NOT ON THESE DRAWINGS. X OCCUPANTS OF THE BUILDING. EXT. EXTERIOR AXXX SHEET NUMBER · 2015 INTERNATIONAL BUILDING CODE (IBC) SCH. SCHEDULE NOTES 14. THE BUILDING SHALL REMAIN IN OPERATION FOR THE DURATION OF 2. CONSTRUCTION OPERATIONS WILL NOT INVOLVE INTERRUPTION OF HEATING, WATER F FAN SIM. SIMILAR THE PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR · 2015 INTERNATIONAL EXISTING BUILDING CODE (IEBC) OR ELECTRICAL SERVICES TO TENANTS OF THE BUILDING. FL FLOOR LEVEL MAINTAINING ALL ENTRANCES AND EXITS. CONTRACTOR SHALL S.S. STAINLESS STEEL PROVIDE ALL NECESSARY BARRICADES, PROTECTION, SIGNAGE, · 2009 ICC A117.1 ACCESSIBLE AND USABLE BUILDING AND FACILITIES FT. FOOT/FEET LIGHTING, ETC. AS REQUIRED TO MAINTAIN SAFE ACCESS/EGRESS TYP. TYPICAL THROUGHOUT. G GAS G001 GA. GAUGE U.L. UNDERWRITERS 15. CONTRACTOR SHALL SUBMIT A PROPOSED PHASING/SITE SAFETY LABORATORY 219068G001.dwg PLAN TO THE OWNER FOR REVIEW PRIOR TO COMMENCEMENT OF GALV. GALVANIZED WORK. VERT. VERTICAL PROJECT NUMBER: VS VENT STACK 16. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING EXISTING HVAC HEATING, VENTILATION, AIR CONDITIONING, COOLING STREET AND SIDEWALK CLOSURE MEASURES, AND SECURING 219050 REQUIRED PERMITS FROM THE CITY OF MIDDLETOWN. COPYRIGHT HOFFMANN ARCHITECTS, INC. 2020 FACADE REPAIRS PARAPET REMOVE AND RESET EXISTING COPING, SEE DETAIL TYPICAL 7 A501 INSTALL NEW COPPER STEP FLASHING ALONG INSIDE FACE OF PARAPET, SEE DETAIL TYPICAL 61 DURANT TERRACE 10 ELEVATOR A501 STAIR SHAFT MIDDLETOWN, CT WALKWAY/PLATFORM CUPOLA WALKWAY/PLATFORM ABOVE BUILDING ADDRESS: 61 DURANT TERRACE MIDDLETOWN, CT 06457 CUPOLA REPLACE EXISTING SEALANT AND BACKER ROD AROUND CLIENT / OWNER: 1 PERIMETERS OF LOUVERS, SEE DETAIL TYPICAL 2 ROOF PLAN 3 ATTIC PLAN CITY OF MIDDLETOWN SCALE: 3/32 = 1'-0" A501 SCALE: 3/32 = 1'-0" A101 A101 245 deKOVEN DRIVE 6 REPAIR DETERIORATED WOOD TRIM, SEE DETAIL TYPICAL A501 MIDDLETOWN, CT 01109 REMOVE AND REPLACE DETERIORATED COPPER FLASHING, SEE DETAIL TYPICAL 11 A501 REPAIR DAMAGED PLASTER ON LIBRARY WALLS, REPAINT REPAIR DAMAGED PLASTER WALLS TO MATCH EXISTING (REFER ON LIBRARY WALLS, REPAINT TO PHOTO FOR EXTENT OF WORK) WALLS TO MATCH EXISTING (REFER TO PHOTO FOR EXTENT OF WORK) DUST ROOM CONFERENCE ROOM OFFICE OFFICE LOBBY ARTS & CRAFTS 5 SOCIALIZATION LIBRARY GAME ROOM NOTICE: 4 1 DO NOT SCALE DRAWINGS. KILN STAIR STAIR ELEVATOR ELEVATOR CONTRACTOR IS RESPONSIBLE FOR ROOM OFFICE VERIFYING ALL DIMENSIONS AND DETAILS. SERVER STORAGE CLOSET STAIR REPORT ANY DISCREPANCIES TO THE ARCHITECT FOR RESOLUTION. STAIR STORAGE CORRIDOR 3 STAIR STAIR 2 STAIR DINING KITCHEN ROOM HOFFMANN ARCHITECTS, INC. MEN WOMEN WOMEN HEALTH PANTRY 2321 WHITNEY AVENUE MENS CLASSROOM CLASSROOM CLASSROOM HAMDEN, CONNECTICUT 06518 SCREENING (203) 239-6660 MECHANICAL STORAGE SEAL: SPRINKLER ELEC. REPAIR DAMAGED PLASTER ON STAIRWELL WALL AND CEILING, REPAINT WALL AND CEILING TO MATCH EXISTING (REFER TO PHOTOS FOR EXTENT OF WORK) 3 UPPER LEVEL PLAN 4 LOWER LEVEL PLAN A101 SCALE: 3/32 = 1'-0" A101 SCALE: 3/32 = 1'-0" 3 DRAWN BY: ELK 9 9 9 REPAIR DAMAGED PLASTER ON WALLS, SEE DETAIL TYPICAL, REPAIR DAMAGED PLASTER ON CEILING, SEE DETAIL TYPICAL, REPAIR DAMAGED PLASTER ON WALLS, SEE DETAIL TYPICAL, A201 CHECKED BY: LEK/RMS A501 A501 A501 REPAINT WALLS TO MATCH EXISTING REPAINT CEILING MATCH EXISTING REPAINT WALLS TO MATCH EXISTING DATE: 9/17/20 ENTRANCE 1 4 4 CANOPY SCALE: AS NOTED A201 A201 A201 OPP.