Notes For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 MOTOR PRODUCT INDEX

PRODUCT SECTION MOTORS No. THREE PHASE TEFC Rolled Steel TEFC 1 Optim® TEFC 3 Advantage Plus IEEE Ready 7 Advantage Plus IEEE 841 10 Optim® TEXP 14 Optim® Oilwell 17 MAX-HT 19 THREE PHASE ODP Rolled Steel ODP 23 A Optim® ODP 26 MEDIUM VOLTAGE Global XPE 29 MOTORS Global TEFC 32 Global ODP 35 SINGLE PHASE Farm Duty 38 PUMP MOTORS Optim® JP 40 Optim® JM 42 Optim® VH 44

Rolled Steel TEFC Optim® TEFC Advantage Plus Advantage Plus Optim® TEXP Optim® Oilwell IEEE Ready IEEE 841

A-1 A-3 A-7 A-10 A-14 A-17

MAX-HT Rolled Steel ODP Optim® ODP Global XPE Global TEFC Global ODP

A-19 A-23 A-26 A-29 A-32 A-35

Farm Duty Optim® JP Optim® JM Optim® VH

A-38 A-40 A-42 A-44

Motor Product Index 1 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 PARTS & ACCESSORIES INDEX

PRODUCT SECTION PARTS & ACCESSORIES No. C-Flange Kits - TEFC - Cast-Iron Optim® TEFC / Global XPE 1 Advantage Plus IEEE Ready 1 Advantage Plus IEEE 841 1 C-Flange Kits - ODP - Cast-Iron Optim® ODP 2 C-Flange Kits - TEFC - Rolled Steel Farm Duty 2 Rolled Steel TEFC 2 C-Flange Kits - ODP - Rolled Steel Rolled Steel ODP 3 C-Flange Kits - TEXP Optim® TEXP 3 Blower Kits B Frames 140T thru 400T 4 Slide Bases Frames 56 thru 5000 5 Labyrinth Seals - Advantage Plus IEEE 841 / Optim® TEFC / Global Inpro/Seal (VBXX) 6 Shaft Grounding Rings AEGIS (SGR) 7 PARTS & ACCESSORIES PARTS Couplings (For Optim® VH Vertical Hollowshaft Motors) Frames 210TP thru 445TP20 / 447/9TP 8 Steady Bushing (For Optim® VH Vertical Hollowshaft Motors) Frames 210TP thru 445TP20 / 447/9TP 9 Alternate P-Flange Kits (For Optim® VH Vertical Hollowshaft Motors) Frames 444/5TP thru 447/9TP 10 NRP Ball Ratchets (For Optim® VH Vertical Hollowshaft Motors) Frames 210TP thru 445TP20 / 447/9TP 10

Parts & Accessories Index 2 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 MODIFICATION & DESCRIPTION INDEX

PRODUCT SECTION MODIFICATIONS No. DESCRIPTION MODIFICATIONS No. DESCRIPTION C-Flange - ODP 12 15 Additional Nameplate - Information Plate 13 16 C-Flange - TEFC 12 15 Grounding Provision 13 16 C-Flange with Inpro/Seal (ADV+) 12 15 Breather Drain Plugs 13 16 D-Flange - ODP 12 15 Drain Holes DE (No Threads/Breather Drains) 13 16 D-Flange - TEFC 12 15 Drain Holes NDE (No Threads/Breather Drains) 13 16 D-Flange with Inpro/Seal (ADV+) 12 15 Tropicalization - Fungus/Corrosion Protection 13 16 Inpro/Seal DE 12 15 Change Rotation 13 16 Inpro/Seal NDE 12 15 Change Cooling Fan (Fan Not Included) 13 16 Special Inpro/Seal DE (ADV+ 841) 12 15 Jacking Bolts 13 16 Special Inpro/Seal NDE (ADV+ 841) 12 15 Drip Cover 13 16 Protech Seal DE (ADV+ 841) 12 15 Drip Cover C/W Vertical Lifting Lugs 13 16 Protech NDE (ADV+ 841) 12 15 Sun-Shield 13 16 F2 Conversion 12 15 Routine Commercial Test as Per IEEE 112 13 17 Space Heaters (CSA Certified) 12 15 Vibration Test & Report as Per IEEE 841 13 17 Thermister 1/PH 12 15 Balance to IEEE 841 Standards 13 17 Klixons 1/PH 12 15 Shaft Grounding (Carbon Type) 13 17 Auxiliary Box 12 15 Shaft Ground Ring 13 17 Auxiliary Box F2 Side 12 15 Shaft Ground Seal (ADV+) 13 17 B Insulated NDE Bearing 12 15 Shaft Ground Seal (Optim VH) 13 17 Insulated DE & NDE Bearing 12 15 Special Paint - Colour (Standard Paint) 13 17 Stainless Steel Hardware 12 15 Special Paint - Epoxy 13 17 Winding RTD 2/PH 12 15 Convert to 3 Lead Motor 13 17 Winding RTD 1/PH 12 15 Extend Main Leads 13 17 Bearing RTD 1/BRG 12 15 Change Bearings to ZZ Type 13 17 MOTOR MODIFICATIONS MOTOR RTD Auxiliary Box 12 16 De-Rate HP 14 17 RTD Auxiliary Box F2 Side 12 16 Re-Rate to 50Hz 14 17 Remove Feet 12 16 Low Temp -50°C 14 17 Oversized Terminal Box - STD 12 16 Convert IEEE Ready to IEEE 841 14 17 Oversized Terminal Box - TYPE II 12 16 Convert Standard TEFC to IEEE 841 14 17 Terminal Block Main Terminal Box 12 16 Locked DE BRG 14 17 Convert Bearings: Ball to Roller 12 16 Rewind Motor 14 17 Convert Bearings: Roller to Ball 12 16 Connect Motor For WYE-Delta Starting 14 17 Custom Shaft - Modify Existing Shaft 13 16 Vertical Lifting Lugs 14 17 Custom Shaft - Replace Existing Shaft 13 16 Modify To IP66 (ADV+ 841 Motors) 14 17 Stub Shaft for Shaft Mounted Encoders 13 16 Oil Mist Lubrication 14 17 Special Grease 13 16 Vibration Provisions 14 17 Nameplate Change 13 16 Aux Blower 14 17

PRODUCT SECTION MODIFICATIONS No. Bearing Cross Reference Table BEARINGS B Bearing Cross Reference Table for Stock Motors 19

PRODUCT SECTION MODIFICATIONS No. DESCRIPTION

CSA Certified Division 1 Space Heaters 14 18

F2 Conversion XP 14 18 B Install C-Flange XP 14 18 Nameplate Change Hazloc 14 18 LOCATION LOCATION HAZARDOUS

MODIFICATION Explosion Proof Adder (When Approved) 14 18

Modification & Description Index 3 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 CONTROL PRODUCT INDEX

PRODUCT SECTION CONTROLS No. TECO DRIVE PRODUCTS FLUXMASTER 50 Micro AC Drive 1 FLUXMASTER 50 NEMA 4 Micro AC Drive 3 FLUXMASTER 50 NEMA 4 Micro AC Drive with Operators 3 L510 Medium Duty Micro AC Drive 6 E510 Medium Duty Compact AC Drive 8 N3 Compact AC Drive 12 N3 Compact AC Drive - Peripherals 14 F510 Fan and Pump AC Drive 15 F510 Fan and Pump AC Drive - Peripherals 17 A510 Heavy Duty AC Drive 18 A510 Heavy Duty AC Drive - Peripherals 23 SP2000 DRIVE PRODUCTS SP2000 All Purpose Drive 24 SP2000 - Overload Selection Chart 25 SP2000 All Purpose Drive - Peripherals 29 SP2000 All Purpose Drive - Communication Peripherals 30 C LOW AND MEDIUM VOLTAGE SOFT STARTS VMX SERIES - Chassis Style Soft- 31 VMX SERIES - Enclosures 33 CONTROLS VMX SERIES - Configured Soft-Starter Systems - Heavy Duty 34 VMX SERIES - Configured Soft-Starter Systems - Standard Duty 34 MVC PLUS SERIES - Medium Voltage Soft-Starter 37 MV Soft Starter Dimensions 39 MV Soft Starter - Across The Line Starters 39 HARMONIC MITIGATION PRODUCTS MTE - Line/Load Reactors 40 MTE - dV/dT Filters 49 MTE - Sine Wave Filters 52 MTE - Matrix Harmonic Filters 56 PROGRAMMABLE LOGIC RELAYS / HMI SG2 - Programmable Logic Relay / HMI 59 CUSTOMER SERVICE Field Service and Start-Up Assistance 61

Control Product Index 4 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 REFERENCE GUIDE INDEX

PRODUCT SECTION INDUCTION MOTOR REFERENCE GUIDE No. ENCLOSURE Drip-Proof Enclosures 1 Totally Enclosed 1 Totally Enclosed Fan Cooled 1 Breather / Drains 1 Space Heaters 1 Rotating Shaft Seal 1 Sealed Leads 1 Explosion-Proof Design 2 Enclosures Summarized 2 Frame Size 3 Frame Suffix Letters 3 MECHANICAL CONSIDERATIONS Motor Mounting 3 Foot Mountings 4 Angle Mountings 4 Flange Mountings 4 Vertical Mountings 4 Coupling Methods 4 Direct Drives 4 Belted Drives 4 Non-Standard Belt Applications 5 Belt Tension 5 Bearings 5 Ball Bearings 5 Using Speed-torque Curves 5 Environment 7 High Ambient Temperature 7 Low Ambient Temperature 7 High Elevation 8 MOTOR DESIGNS Horsepower Formula 8 Torque Terminology 9 NEMA Designs A, B, C 10 NEMA Design D 11 NEMA Design F 12 POWER SUPPLY Full Load Current 13 D Voltage 13 Locked Rotor kVA Code Letter 13 Rated Frequency and Number of Phases 14 50 Cycle Motors 14 Service Factor 14 MOTOR EFFICIENCY Motor Efficiency 15 TWMI Energy Saving Example 15 STARTING METHODS Starting Methods for Squirrel Cage Motors 15 Auto-Transformer 16 Resistor 16 Reactor 16 Effect of Reduced Voltage Starting 16 VFD DRIVEN MOTOR APPLICATIONS Variable Speed Applications 18 Effects of Harmonics on Induction Motors 18 Motor Insulation System & Supply Voltage 18 Cable Length & Type 18 Motor Shaft Voltages & Bearing Currents 19 INDUCTION MOTOR REFERENCE GUIDE INDUCTION MOTOR VFD Carrier Frequency Settings 19 VFD Application in Hazardous Locations 19 INSULATION Insulation Types and Temperature Rise 20 Service Factor 21 FIELD SERVICE Excessive Vibration 22 Excessive Noise 23 High Current 24 Running Hot 25 Bearing Failures 25 Motor Burned Out 28 USEFUL INFORMATION Useful Information 28 Re-Lubrication Guidelines 29 Formulas 31

Induction Motor Reference Guide Index 5 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 TAILORED DISCOUNT STRUCTURE

PRODUCT MOTORS MULTIPLIER

THREE PHASE TEFC

Rolled Steel TEFC

Optim® TEFC

Advantage Plus IEEE Ready

Advantage Plus IEEE 841

Optim® TEXP

Optim® Oilwell

MAX-HT

THREE PHASE ODP

Rolled Steel ODP

Optim® ODP

MEDIUM VOLTAGE MOTORS Global XPE

Global TEFC

Global ODP

SINGLE PHASE

Farm Duty

PUMP MOTORS

Optim® JP

Optim® JM

Optim® VH

Tailored Discount Structure 6 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 TAILORED DISCOUNT STRUCTURE

PRODUCT CONTROLS MULTIPLIER

TECO VFD Peripherals

TECO VFD's

SP2000 PRODUCTS

VMX Low Voltage Soft Starters

MVC MV Soft Starters

MTE Reactors

MTE DVDT Filters: CONTROLS

MTE Sine Wave Filters

MTE Matrix Harmonic Filters

Programmable Logic Products

Tailored Discount Structure 7 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 SELLING POLICY Selling Policy TWMI 2500 (E) 02/18 Supersedes Selling Policy TWMI 2500 (E) 05/13

Definition Credit Approval This warranty is conditioned upon the installation, Acceptance of a purchase order is subject to approval of operation, and maintenance of the motors in accordance The term “Company” shall be deemed to include TECO- the Purchaser’s credit by the Company. Notwithstanding with TECO- Westinghouse Motors (Canada) Inc. Westinghouse Motors (Canada) Inc. and its affiliates as such acceptance and/or approval, if in the Company’s recommendations or standard industry practice and the case may be. judgment the purchaser’s financial condition does not the motors have at all times been operating or used at any time warrant the continuation of production of under normal operating conditions for which they were Price Policy shipment of the original terms, the Company reserves designed. the right to request payment in advance or other surety. List Prices and Discounts TECO–Westinghouse Motors (Canada) Inc. shall, at Prices and discounts are subject to change without Minimum Billing its sole option and expense, either repair or replace, notice prior to entry of order. The minimum billing for any one order shall be $150 net. F.O.B.TWMI warehouse, any such motor or part which is defective within the warranty period. Price Adjustment Quotations The contract price, excluding sales taxes and erection Unless specified in a proposal, written quotations In the event of a warranty claim, TECO–Westinghouse and service is subject to the following condition: automatically expire thirty calendar days from like date Motors (Canada) Inc. must be notified promptly issued. Verbal quotations expire the same day they are following any motor failure. The motor shall be sent to The contract price is firm for shipments made within 12 made unless confirmed in writing, whereupon they a TECO–Westinghouse Motors (Canada) Inc. authorized months from the date of quotation by the Company. expire thirty days from the date issued. service center for diagnosis on the cause of failure. If the failure is due to defective material and/or workmanship, Taxes Shipping Policy TECO–Westinghouse Motors (Canada) Inc. will replace or Where prices include Government taxes, they are in repair the defective motor or part. accordance with the law and regulations in effect at Factory Shipments the date of the proposal or quotation. Such prices are Unless otherwise stated, CIF Ocean Port of entry in The repair or replacement of defective material and subject to increase or decrease to reflect changes in Canada. All other freight extra. workmanship shall constitute complete fulfillment of taxes levied by Governments made prior to delivery of TECO–Westinghouse Motors (Canada) Inc. warranty the product. Warehouse Shipments / Normally Stocked Items liability whether the warranty claims are based on Shipping terms are F.O.B. point of shipment with freight contract, tort (including negligence and strict liability), Prices do not include Federal Sales Tax. Provincial and prepaid and allowed to first Canadian destination or otherwise. municipal taxes, where applicable will be added to the serviced by a common carrier provided shipment is prices quoted. greater than $5000. There will be one single Canadian Controls Warranty destination per shipment prepaid. If shipment value is TWMI warrants Control Products for the period of one Terms of Payment less than $5000 freight charges will be collect. year from the date of invoice to be of merchantable All payments shall be in Canadian dollars. Unless quality, free from defects in material, workmanship and authorized differently on a specific negotiation, the Delivery design. Warranty is limited to the exchange or repair of Company’s standard terms of payment will apply. Unless otherwise expressly agreed in writing, delivery products. Warranty does not apply to the application of the product will be made F.O.B. the Company’s or installation of products, service, shipping or 1. On orders under $200,000 in value – 100% net 30 factory or warehouse. Delivery dates specified are transportation costs associated with return or exchange days. No cash discount. subject to prior sale of manufacturing and engineering of goods. space and to the receipt of all information necessary to 2. On orders $200,000 and over and/or with shipping allow maintenance of the Company’s engineering and Packaged Solutions Warranty schedule exceeding 6 months, progress payments will manufacturing schedules. TWMI warrants Control Products that are commissioned be required. The standard Company progress payments by an authorized TWMI Service Representative for the are: Loss or Damage in Transit period of two years from the Commissioning Date to be The Company does not hold itself responsible for any of merchantable quality, free from defects in material, a) 10% of the contract price on receipt of order. loss, damage or pilferage sustained in transit, having workmanship and design and that the products supplied obtained “in good order” receipts from the carrier. are suitable for the intended application. Warranty is b) 10% of the contract price on submission of drawings. Claims of such character should be made promptly limited to the exchange or repair of products. Warranty against the carrier. If the Company is notified in does not apply to installation of products, shipping or c) 40% on completion of major components ( writing of such claims, it will lend assistance to secure transportation costs associated with return or exchange core, rotor core, motor frame) adjustment. of goods or to any subsequent service costs. d) 30% due on readiness to ship from the factory. Shipment F.O.B. Destination Warranty is conditioned upon the installation, The Company agrees to deliver the product F.O.B. operation and maintenance of the Control Products e) 10% of contract price 30 days from Bill of Lading. Destination, the Purchaser shall examine the product as in accordance with TECO-Westinghouse (Canada) Inc. soon as it is received and shall within ten days thereafter recommendations or standard industry practices and In case partial shipments are made at different times, give notice to the Company and shall notify the carrier of the Controls at all times being operated or used under pro-rated payments shall be made therefore. any loss or damage sustained during transit, and further normal operating conditions for which they were in the case of any damage, the Purchaser shall request designed. If shipments of the product specified, or any material an inspection of the Loss or Damage by a representative part thereof, are delayed from any cause for which the of the delivering carrier and a copy of the carrier’s TECO-Westinghouse Motors (Canada) Inc. shall, at its sole Purchaser is directly or indirectly responsible, the date Inspection Report shall be sent to the Company. If such option and expense, either repair or replace, F.O.B.TWMI of completion of the product by the Company shall notice to the Company or to the delivering carrier is warehouse, any such Control Product or part there of be regarded as the date of shipment in determining not given, the product shall be deemed to have been which is defective within the warranty period. when payments for said products are to be made, and delivered in satisfactory condition and the price shall the Company shall be entitled to receive reasonable become due and payable in full as agreed between the In the event of a warranty claim, TECO-Westinghouse compensation for storing the completed product which Company and the Purchaser. Motors (Canada) Inc. must be notified promptly shall be held at the purchaser’s risk. Normally, the following the Control Product failure. The Control Company will inform the Purchaser in writing of the date Warranty Product shall be sent prepaid to TECO-Westinghouse of completion. The Purchaser agrees that should any of Motors (Canada) Inc. authorized service center for the payments not be made to the Company when due in Stock Motor Warranty diagnosis on the cause of failure. If the cause of failure is accordance with these terms, the Purchaser shall pay the All TECO–Westinghouse brand stock motors sold by due to defective material, workmanship or design, TECO- Company interest on such overdue payments at the rate TECO–Westinghouse Motors (Canada) Inc. are warranted Westinghouse Motors (Canada) Inc. will replace or repair of 18% per year. to be free of defects in material and workmanship for the defective Control or Part. a period of thirty-six (36) months from the date of sale or in the case of Advantage Plus IEEE 841, five (5) years from date of sale. (Continued ...)

Selling Policy 8 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 SELLING POLICY Selling Policy TWMI 2500 (E) 02/18 Supersedes Selling Policy TWMI 2500 (E) 05/12

The repair or replacement of defective material and These corrections will be made at the customer’s insofar as the same are based on any claim that the said workmanship shall constitute complete fulfillment of expense if corrections required are due to storage product or any part thereof constitutes an infringement TECO-Westinghouse Motors (Canada) Inc. warranty conditions. of any claim of a Canadian patent, other than a claim liability whether the warranty claims are based on occurring a process or a product thereof, provided the contract, tort (including negligence and strict liability), 3. That an affidavit certifying that the apparatus has Purchaser gives the Company immediate notice in or otherwise. successfully passed the inspection and is in “as writing of the institution of the actions or proceedings shipped” condition be supplied to TWMI by the and permits the Company through its council to defend Engineered Motor Warranty customer. Failure to provide TWMI with the affidavit the same and give the Company all needed information, Where the product sold by the Company is also certifying that the apparatus has passed inspection assistance and authority to enable the Company so manufactured by the Company, the Company warrants and is in “as shipped” condition will result in voiding to do. In case such product is in such action held to the product supplied hereunder to be of the kind the warranty. constitute infringement, and its use is enjoyed, the designated or specified. Unless otherwise expressly Company, within a reasonable time, will either secure agreed in writing, the company shall repair or replace B. Extending Operational Warranty: for the Purchaser the right to continue using said any defective part or parts, F.O.B. the Company’s plant, Extended Operational Warranties are available per the product by suspension of the injunction, by procuring warehouse, or its designated service facility, which prove following: for the Purchaser a license or otherwise or will at its to be defective under normal and proper use within own expense, replace such product with non-infringing (one) 1 year from the date of installation or eighteen Total Warranty Period (Months) % Addition product or modify it so that it becomes non-infringing or (18) months from date of shipment, whichever occurs remove the said enjoined product and refund the sums earlier, provided that the Purchaser gives the Company 18 (12 operational) 0 (standard) paid therefore. immediate written notice of any such defect or defects. 30 (24 operational) 3% On expiration of the Warranty period, any liability of the 42 (24 operational) 5% Limitation of Liability Company shall terminate. 48 (36 operational) 7% Notwithstanding any other provision in this Agreement or any applicable statutory provisions, the Company Where the product sold by the Company is not also Longer operational warranties are available, but must be shall not be liable to the Purchaser for any special manufactured by the Company, it is the product of a negotiated with TWMI. or consequential or incidental or punitive damages reputable manufacturer sold under that manufacturer’s including but not limited to loss of profits or revenues, brand or trade name and the Company warrants that it The applicable Warranty expressed in this paragraph loss off use of the equipment, loss of opportunities, will fulfill the same warranty obligations as it receives constitutes the only Warranty of the Company and no loss of goodwill, interruption of business, or down time from the manufacturer. other warrant or condition, statutory or otherwise, shall costs and in no event shall the aggregate liability of the be implied. Company exceed the unit price of the defective product, Optional Warranties: part or service on which the such liability is based. The THERE ARE NO OTHER WARRANTIES, EXPRESS OR provisions of this article, and of all other sections of the A. Deferred Warranty: IMPLIED, INCLUDING ANY IMPLIED WARRANTY Agreement providing for limitation of or protection The standard warranty shall apply subject to the OF MERCHANTABILITY AND FITNESS FOR against liability of the Company, shall also protect its following modification: PARTICULAR PURPOSE, AND ALL WARRANTIES direct and indirect suppliers and its subcontractors and ARISING FROM COURSE OF DEALING AND USAGE shall apply to the full extent permitted by law and shall The total warranty period will be a period of one year OF TRADE. UNDER NO CIRCUMSTANCES, SHALL survive the termination, cancellation or expiration of this from date of initial operation but not in excess of the TECO-WESTINGHOUSE MOTORS (CANADA) Agreement. total warranty period selected. INC. BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL In the event any product, part or service sold by the For the total warranty period desired, make the addition DAMAGES, INCLUDING FREIGHT. Company hereunder is the subject of a resale by the from the table to the net price of each unit. Purchaser, Purchaser agrees to bind his customer to Title provisions limiting the liability of Purchaser and its Total Warranty Period (Months) % Addition The title to the product or any part thereof shall pass suppliers and subcontractors which are the same from the Company as soon as all payments due have as the corresponding provisions of this Agreement 18 (12 operational) 0 (standard) been fully made in cash, except as otherwise expressly and Purchaser shall indemnify and save harmless the 30 (12 operational) 1% stipulated herein. The said product shall be and Company from any claims, loss or damage arising 36 (12 operational) 2% remain personal property, notwithstanding its mode directly or indirectly from the Purchaser’s failure to do so. 42 (12 operational) 3% of attachment to realty or other property. If default is 48 (12 operational) 4% made in any of the payments herein, the Company may Returned Material 54 (12 operational) 5% retain any partial payments which have been made, as The Company’s permission must be obtained before 60 (12 operational) 6% liquidated damages and the Company shall be entitled returning any material whereupon it will furnish to the immediate possession of the product and shall shipping instructions and tags. Any material returned The deferred warranty is valid only if the following be free to enter the premises where the product may without permission will be held at Purchaser’s risk and is conditions are complied with: be located and remove it as the Company’s property, liable to non-acceptance or delay in approval of credit. without prejudice to the Company’s right to recover Only standard stocked product may be returned for 1. That within thirty days prior to initial operation, a any further expenses or damages the Company suffer credit. When permission is granted for the return of TWMI Service Engineer be hired by the customer by reason of such non-payment. Notwithstanding the material, credit will be allowed for the invoiced price to thoroughly inspect the apparatus to ascertain terms hereof, risk will pass to the purchaser at point of less a restocking charge and less transportation charges. that the apparatus is in “as shipped” condition. This delivery. Any cost incurred in putting the material in salable inspection will include but not be limited to: condition shall be deducted from the allowed credit. Force Majeure a) Meggar test of winding insulation. The Company shall not be responsible or liable for Cancellation or Changes any loss, damage, detention or delay caused by war, Any order may be canceled or altered by the Purchaser b) Internal inspection to determine that the winding invasion, insurrection, riot, the order of any civil or only upon payment of reasonable charges based upon has not been damaged and that the apparatus is military authority, or by fire, flood weather or to other expenses already incurred and commitments made by clean and dry. acts of the elements, breakdown, lockouts, strikes or the company with respect to the order. labor disputes, the failure of the Company’s suppliers c) Inspection of the bearings to determine they have to meet their contractual obligations, or, without Installation not been damaged and that there is no water in limitations of the foregoing, any other cause beyond the The product shall be installed by and at the expense of the oil reservoirs. reasonable control of the Company and the receiving of the Purchaser, unless otherwise expressly stipulated. the product by the Purchaser shall constitute a waiver of d) External inspection to determine that no damage all claims for loss or damage due to delay. Special Packing has been done. Catalogue prices include domestic packing only. Where Patents special packing is required, refer to the Company. 2. Make any corrections which this inspection shows The Company’s agrees that it will at its own expense to be needed because the apparatus has been in defend all actions or proceedings instituted against Special Testing storage or standing idle. the Purchaser and pay any award of damages assessed If witness or other tests are required, refer to the against the Purchaser in such actions or proceedings, Company.

Selling Policy 9 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 STANDARD WARRANTY FOR STOCK MOTORS

All TECO–Westinghouse brand stock motors sold by TECO–Westinghouse Motors (Canada) Inc. are warranted to be free of defects in material and workmanship for a period of 36 months from the date of sale (Advantage Plus 5 Year Warranty - IEEE 841 only).

This warranty is conditioned upon the installation, operation, and maintenance of the motors in accordance with TECO–Westinghouse Motors (Canada) Inc. recommendations or standard industry practice and the motors have at all times been operating or used under normal operating conditions for which they were designed.

TECO–Westinghouse Motors (Canada) Inc. shall, at its sole option and expense, either repair or replace, F.O.B. TWMI warehouse, any such motor or part which is defective within the warranty period.

In the event of a warranty claim, TECO–Westinghouse Motors (Canada) Inc. must be notified promptly following any motor failure. The motor shall be sent to a TECO–Westinghouse Motors (Canada) Inc. authorized service center for diagnosis on the cause of failure. If the failure is due to defective material and/or workmanship, TECO–Westinghouse Motors (Canada) Inc. will replace or repair the defective motor or part.

The repair or replacement of defective material and workmanship shall constitute complete fulfillment of TECO–Westinghouse Motors (Canada) Inc. warranty liability whether the warranty claims are based on contract, tort (including negligence and strict liability), or otherwise.

THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE, AND ALL WARRANTIES ARISING FROM COURSE OF DEALING AND USAGE OF TRADE. UNDER NO CIRCUMSTANCES, SHALL TECO-WESTINGHOUSE MOTORS (CANADA) INC. BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING FREIGHT.

ONLINE WARRANTY INSTRUCTIONS ARE AVAILABLE AT: www.tecowestinghouse.ca/support/warranty

Standard Warranty for Stock Motors 10 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 STANDARD WARRANTY FOR CONTROLS

WARRANTY CONTROL PRODUCTS

TWMI warrants Control Products for the period of one year from the date of invoice to be of merchantable quality, free from defects in material, workmanship and design. Warranty is limited to the exchange or repair of products. Warranty does not apply to the application or installation of products, service, shipping or transportation costs associated with return or exchange of goods.

WARRANTY PACKAGED SOLUTIONS

TWMI warrants Control Products that are commissioned by an authorized TWMI Service Representative for the period of two years from the Commissioning Date to be of merchantable quality, free from defects in material, workmanship and design and that the products supplied are suitable for the intended application. Warranty is limited to the exchange or repair of products. Warranty does not apply to installation of products, shipping or transportation costs associated with return or exchange of goods or to any subsequent service costs.

Warranty is conditioned upon the installation, operation and maintenance of the Control Products in accordance with TECO-Westinghouse (Canada) Inc. recommendations or standard industry practices and the Controls at all times being operated or used under normal operating conditions for which they were designed.

TECO-Westinghouse Motors (Canada) Inc. shall, at its sole option and expense, either repair or replace, F.O.B. TWMI warehouse, any such Control Product or part there of which is defective within the warranty period.

In the event of a warranty claim, TECO-Westinghouse Motors (Canada) Inc. must be notified promptly following the Control Product failure. The Control Product shall be sent prepaid to TECO-Westinghouse Motors (Canada) Inc. authorized service center for diagnosis on the cause of failure. If the cause of failure is due to defective material, workmanship or design, TECO- Westinghouse Motors (Canada) Inc. will replace or repair the defective Control or Part.

The repair or replacement of defective material and workmanship shall constitute complete fulfillment of TECO-Westinghouse Motors (Canada) Inc. warranty liability whether the warranty claims are based on contract, tort (including negligence and strict liability), or otherwise.

THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE, AND ALL WARRANTIES ARISING FROM COURSE OF DEALING AND USAGE OF TRADE. UNDER NO CIRCUMSTANCES, SHALL TECO-WESTINGHOUSE MOTORS (CANADA) INC. BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING FREIGHT.

Standard Warranty for Controls 11 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 TECO WESTINGHOUSE MOTORS (CANADA) INC.

Blank 12 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FEATURES

MODEL: ROLLED STEEL TEFC TYPE: AEGH/AEGHPE Effective 05-01-18 Supercedes All Previous

APPLICATIONS • Fans & Blowers • Pumps • Compressors • HVAC Equipment

PRODUCT OVERVIEW • 1/4-10HP • Totally Enclosed Fan Cooled IP44 Design • 56/56C Frame Available 1/4-3HP • Horizontal F1 Mount • 60Hz, 230/460V, or 575V • NEMA Premium Efficiency (T Frame) • 3600, 1800 & 1200 RPM • MEPS Efficiency (56 Frame)

DESIGN FEATURES • 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power • NEMA Design B • Continuous Duty • 40˚C Ambient • Class F Insulation • Max Elevation 3300ft

MECHANICAL FEATURES • Shielded Bearings • Multemp SRL Grease • Aluminum Rotor • Rolled Steel Frame with Cast-Iron End Brackets • Rolled Steel Conduit Box • Number of Leads 230/460V: 9 Leads 1/4-5HP; 12 Leads 7.5 and Larger; 575V: 3 Leads • Solderless Lug Terminals on All Leads • Grounding Terminal Inside Main Terminal Box • Plastic Fan • Paint System: Phenolic Rust Proof Base with Lacquer Top Coat • Stainless Steel Nameplate • Rubber Flinger on DE • *HPE™ High Pulse Endurance Spike Resistant Wire • Phenolic Alkyd Resin Varnish • Bi-Directional Rotation • 230/460V Motors Usable on 208V (Sinusoidal Power Only)

OTHER FEATURES • CSA Certified, UL recognized and CE marked • CSA Energy Efficiency Verification (EEV) • *Meets NEMA MG1 Part 31.4.4.2 • *Speed Range 10:1 CT, and 20:1 VT

* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.

Motor Products - ROLLED STEEL TEFC A - 1 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES PREMIUM EFFICIENCY TEFC

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 230V/460V 575V 460V 575V EFF. WT. LBS PRICE RF0/22 RF0/225 0.25 3600 56 0.40 0.32 72.0 20 159 RF0/24 RF0/245 0.25 1800 56 0.45 0.36 72.0 21 162 RF0/26 RF0/265 0.25 1200 56 0.55 0.44 70.0 25 188 RF0/32 RF0/325 0.33 3600 56 0.54 0.43 71.5 20 167 RF0/34 RF0/345 0.33 1800 56 0.56 0.44 75.5 22 172 RF0/36 RF0/365 0.33 1200 56 0.71 0.57 72.0 26 204 RF0/52 RF0/525 0.50 3600 56 0.79 0.63 73.4 21 179 RF0/54 RF0/545 0.50 1800 56 0.74 0.59 78.2 25 185 RF0/56 RF0/565 0.50 1200 56 0.99 0.79 75.5 32 239 RF0/72 RF0/725 0.75 3600 56 1.15 0.92 76.8 23 188 RF0/74 RF0/745 0.75 1800 56 1.12 0.89 81.1 25 191 RF0/76 RF0/765 0.75 1200 56 1.28 1.02 81.7 33 279 RF0012-56 RF00125-56 1 3600 56 1.53 1.22 77.0 30 202 RF0012 RF00125 1 3600 143T 1.37 1.10 80.0 29 281 RF0014-56 RF00145-56 1 1800 56 1.56 1.24 83.5 32 242 RF0014 RF00145 1 1800 143T 1.45 1.16 85.5 36 268 RF0016-56 RF00165-56 1 1200 56 1.72 1.38 82.5 38 321 RF0016 RF00165 1 1200 145T 1.72 1.38 82.5 37 321 RF1/52-56 RF1/525-56 1.5 3600 56 1.98 1.58 85.5 30 251 RF1/52 RF1/525 1.5 3600 143T 1.98 1.58 85.5 29 301 RF1/54-56 RF1/545-56 1.5 1800 56 2.02 1.61 86.5 39 306 RF1/54 RF1/545 1.5 1800 145T 2.02 1.61 86.5 40 294 RF1/56-56 RF1/565-56 1.5 1200 56 2.47 1.97 83.8 57 351 RF1/56 RF1/565 1.5 1200 182T 2.92 2.33 87.5 65 359 RF0022-56 RF00225-56 2 3600 56 2.55 2.04 86.5 37 277 RF0022 RF00225 2 3600 145T 2.55 2.04 86.5 36 334 RF0024-56 RF00245-56 2 1800 56 2.74 2.19 86.5 41 332 RF0024 RF00245 2 1800 145T 2.74 2.19 86.5 40 326 RF0026 RF00265 2 1200 184T 3.28 2.62 88.5 84 413 RF0032-56 RF00325-56 3 3600 56 3.65 2.92 86.5 39 317 RF0032 RF00325 3 3600 182T 3.67 2.94 87.5 73 367 RF0034-56 RF00345-56 3 1800 56 4.04 3.23 86.9 59 357 RF0034 RF00345 3 1800 182T 4.24 3.39 89.5 60 367 RF0036 RF00365 3 1200 213T 4.62 3.69 89.5 126 614 RF0052 RF00525 5 3600 184T 5.81 4.65 89.5 84 446 RF0054 RF00545 5 1800 184T 6.54 5.23 89.5 82 425 RF0056 RF00565 5 1200 215T 7.06 5.65 90.2 164 737 RF7/52 RF7/525 7.5 3600 213T 9.21 7.37 90.2 123 609 RF7/54 RF7/545 7.5 1800 213T 9.23 7.38 91.7 117 610 RF0102 RF01025 10 3600 215T 11.96 9.57 91.0 162 721 RF0104 RF01045 10 1800 215T 12.01 9.61 91.7 159 734

NOTE: (1) Prices subject to change without notice. (2) For VFD applcations please refer to page D-18.

Motor Products - ROLLED STEEL TEFC A - 2 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FEATURES

MODEL: OPTIM® TEFC TYPE: AEHH8N, AEHE Effective 05-01-18 Supercedes All Previous

APPLICATIONS • Fans & Blowers • Crushers • Mixers • Pumps • Compressor • Conveyors

PRODUCT OVERVIEW • 1-800HP • Totally Enclosed Fan Cooled IP54 Design, IP55 for 5000 Frames and Larger • 60Hz, 230/460V, 460V or 575V • Horizontal F1 Mount • 3600, 1800, 1200 & 900 RPM • NEMA Premium Efficiency

DESIGN FEATURES • 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power • Class F Insulation • Max Elevation 3300ft • Continuous Duty • NEMA Design B or C • 40˚C Ambient

MECHANICAL FEATURES • Shielded Bearings Frames 140T-280T and Open Bearings with Regreaseable Provisions Frames 280TS, 320T and Larger • Polyrex EM Grease in all Regreaseable Bearings, Multemp SRL Grease in Shielded Bearings • Aluminum Rotor up to 5000 Frames; Copper/Copper Alloy 5800 and Larger • Cast-Iron Frame and End Brackets • Cast-Iron Conduit Box up to 449T Frames; Fabricated Steel Conduit Box 5000 Frames and Larger • Non-Sparking Plastic Fan up to 449T 4,6 & 8 Pole Motors; Bronze Fan 440TS 2 Pole Motors; Aluminum Fan 5000 Frames and Larger • Number of Leads 230/460V: 9 Leads 1-5HP; 12 Leads 7.5-125HP; 6 Leads 150 and Above • Number of Leads 575V: 3 Leads up to 449T; 6 Leads 5000 Frames and Larger • Solderless Lug Terminals on All Leads • Grounding Terminal Inside Main Terminal Box, Additional Grounding Terminal on Frame for 5000 Frames and Larger • Interchangeable F1 and F2 mounting up to 449T • Dual Drilled Feet for Longer Frames (i.e. 145T also Drilled for 143T) 449T and Below • Paint System: Phenolic Rust Proof Base with Lacquer Top Coat • Insulated NDE Bearing Standard for 600HP and Larger (2 Pole Motors Only) • Rubber Flinger on DE up to 280T; Steel Flinger on Both Ends 280TS and Larger • *HPE™ High Pulse Endurance Spike Resistant Wire • 2 Dips Phenolic Alkyd Resin Varnish 140T-440T, 2 Dips Epoxy Resin 5000 Frames and Larger; Spray Enamel Top Coat on all Frames • Bi-Directional Rotation Except 3600RPM Motors 5000 Frames and Larger Which are CW From NDE • Winding RTD's, Space Heaters and Provisions for Bearing RTD's Standard 5000 Frames and Larger

OTHER FEATURES • CSA Certified for Class I, Division 2, Groups B, C & D (Class I, Zone 2, Groups IIB+H2, IIB and IIA) • CSA Certified Class II, Division 2 (Class II, Zone 22) available for 440 Frames and larger upon request • *Speed Ranges up to 10:1 CT, and 20:1 VT. Refer to data sheet for rating specific turn down ratios • *Meets NEMA MG1 Part 31.4.4.2

* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.

Motor Products - OPTIM® TEFC A - 3 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES PREMIUM EFFICIENCY TEFC SEVERE DUTY

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 230V/460V 575V 460V 575V EFF. WT. LBS PRICE PDH0012 PDH00125 1 3600 143T 1.34 1.07 82.5 46 341 PDH0014 PDH00145 1 1800 143T 1.50 1.20 85.5 46 297 PDH0016 PDH00165 1 1200 145T 1.73 1.38 82.5 62 361 PDH0018 PDH00185 1 900 182T 2.08 1.66 77.0 95 573 PDH1/52 PDH1/525 1.5 3600 143T 2.00 1.60 84.0 46 355 PDH1/54 PDH1/545 1.5 1800 145T 2.08 1.66 86.5 62 329 PDH1/56 PDH1/565 1.5 1200 182T 2.53 2.02 87.5 84 401 PDH1/58 PDH1/585 1.5 900 184T 3.01 2.41 77.0 114 619 PDH0022 PDH00225 2 3600 145T 2.52 2.02 86.5 62 375 PDH0024 PDH00245 2 1800 145T 2.78 2.22 86.5 62 362 PDH0026 PDH00265 2 1200 184T 3.00 2.40 88.5 101 453 PDH0028 PDH00285 2 900 213T 3.42 2.74 85.5 167 702 PDH0032 PDH00325 3 3600 182T 3.53 2.82 88.5 84 433 PDH0034 PDH00345 3 1800 182T 3.74 2.99 89.5 84 407 PDH0036 PDH00365 3 1200 213T 4.02 3.22 89.5 167 612 PDH0038 PDH00385 3 900 215T 4.98 3.98 85.5 189 807 PDH0052 PDH00525 5 3600 184T 5.72 4.58 88.5 101 504 PDH0054 PDH00545 5 1800 184T 6.12 4.90 89.5 101 477 PDH0056 PDH00565 5 1200 215T 6.24 4.99 91.0 194 807 PDH0058 PDH00585 5 900 254T 7.52 6.02 86.5 288 1,098 PDH7/52 PDH7/525 7.5 3600 213T 8.67 6.94 91.0 167 667 PDH7/54 PDH7/545 7.5 1800 213T 8.85 7.08 91.7 167 671 PDH7/56 PDH7/565 7.5 1200 254T 9.59 7.67 91.0 297 1,084 PDH7/58 PDH7/585 7.5 900 256T 11.5 9.20 85.5 332 1,451 PDH0102 PDH01025 10 3600 215T 11.5 9.20 91.0 194 795 PDH0104 PDH01045 10 1800 215T 11.6 9.28 91.7 194 811 PDH0106 PDH01065 10 1200 256T 12.8 10.2 91.0 337 1,344 PDH0108 PDH01085 10 900 284T 14.2 11.4 89.5 429 1,962 PDH0152 PDH01525 15 3600 254T 16.6 13.3 92.4 297 1,053 PDH0154 PDH01545 15 1800 254T 17.3 13.8 92.4 297 1,096 PDH0156 PDH01565 15 1200 284T 18.2 14.6 92.4 418 1,778 PDH0158 PDH01585 15 900 286T 20.1 16.1 89.5 475 2,422 PDH0202 PDH02025 20 3600 256T 21.9 17.5 92.4 337 1,426 PDH0204 PDH02045 20 1800 256T 23.0 18.4 93.0 337 1,342 PDH0206 PDH02065 20 1200 286T 24.3 19.4 91.7 475 2,207 PDH0208 PDH02085 20 900 324T 25.6 20.5 90.2 664 3,027 PDH0252 PDH02525 25 3600 284TS 27.8 22.2 92.4 394 1,786 PDH0254 PDH02545 25 1800 284T 29.1 23.3 93.6 418 1,703 PDH0256 PDH02565 25 1200 324T 30.3 24.2 93.0 638 2,734 PDH0258 PDH02585 25 900 326T 32.6 26.1 90.2 724 3,496 PDH0302 PDH03025 30 3600 286TS 33.2 26.6 93.0 444 2,079 PDH0304 PDH03045 30 1800 286T 34.3 27.4 93.6 475 1,978 PDH0306 PDH03065 30 1200 326T 37.5 30.0 93.0 675 3,347 PDH0308 PDH03085 30 900 364T 39.0 31.2 93.0 898 4,480

NOTE: (1) Prices subject to change without notice. (2) Ratings over 125HP are single voltage rated (460V). (3) For 50Hz, please contact a TWMI representative. (4) For belt drive application, please contact a TWMI representative. (5) For VFD applcations please refer to page D-18.

Motor Products - OPTIM® TEFC A - 4 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES PREMIUM EFFICIENCY TEFC SEVERE DUTY

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 230V/460V 575V 460V 575V EFF. WT. LBS PRICE PDH0402 PDH04025 40 3600 324TS 44.2 35.4 94.1 616 2,761 PDH0404 PDH04045 40 1800 324T 46.3 37.0 94.1 638 2,713 PDH0406 PDH04065 40 1200 364T 46.0 36.8 94.1 834 4,432 PDH0408 PDH04085 40 900 365T 53.4 42.7 91.7 928 5,629 PDH0502 PDH05025 50 3600 326TS 54.7 43.8 94.1 638 3,607 PDH0504 PDH05045 50 1800 326T 56.9 45.5 94.5 675 3,255 PDH0506 PDH05065 50 1200 365T 57.8 46.2 94.1 913 5,174 PDH0508 PDH05085 50 900 404T 62.5 50.0 93.0 1166 6,571 PDH0602 PDH06025 60 3600 364TS 64.2 51.4 94.1 759 4,781 PDH0604 PDH06045 60 1800 364T 68.4 54.7 95.0 834 4,321 PDH0606 PDH06065 60 1200 404T 68.3 54.6 94.5 1166 5,968 PDH0608 PDH06085 60 900 405T 74.6 59.7 93.0 1298 7,596 PDH0752 PDH07525 75 3600 365TS 79.9 63.9 94.5 818 6,002 PDH0754 PDH07545 75 1800 365T 85.1 68.1 95.4 913 5,795 PDH0756 PDH07565 75 1200 405T 85.9 68.7 94.5 1298 7,137 PDH0758 PDH07585 75 900 444T 95.6 76.5 93.0 1600 9,861 PDH1002 PDH10025 100 3600 405TS 107 85.6 95.4 1144 8,061 PDH1004 PDH10045 100 1800 405T 112 89.6 95.4 1298 7,481 PDH1006 PDH10065 100 1200 444T 119 95.2 95.0 1600 9,974 PDH1008 PDH10085 100 900 445T 127 102 93.0 1800 13,589 PDH1252 PDH12525 125 3600 444TS 143 114 95.0 1600 10,685 PDH1254 PDH12545 125 1800 444T 146 117 95.4 1600 9,591 PDH1256 PDH12565 125 1200 445T 148 118 95.0 1700 12,208 PDH1258 PDH12585 125 900 447T 156 125 93.6 2450 16,247 PDH1502 PDH15025 150 3600 445TS 170 136 95.0 1700 12,439 PDH1504 PDH15045 150 1800 445T 175 140 95.8 1780 10,814 PDH1506 PDH15065 150 1200 447T 176 141 95.8 2170 13,959 PDH1508 PDH15085 150 900 449T 188 150 93.6 2800 19,371 PDH2002 PDH20025 200 3600 447TS 226 181 95.4 1900 16,044 PDH2004 PDH20045 200 1800 447T 230 184 96.2 2220 13,550 PDH2006 PDH20065 200 1200 449T 233 186 95.8 2450 16,950 PDH2008 PDH20085 200 900 449T 249 199 94.0 3200 21,993 PDH2008L PDH20085L 200 900 5007B 249 199 94.0 3200 27,172 PDH2502 PDH25025 250 3600 449TS 278 222 95.8 2320 19,731 PDH2504 PDH25045 250 1800 449T 285 228 96.2 2450 16,984 PDH2506 PDH25065 250 1200 449T 289 231 95.8 2560 20,333 PDH2508 PDH25085 250 900 5009B 306 245 93.5 4100 30,625 PDH3002 PDH30025 300 3600 449TS 333 266 95.8 2550 24,033 PDH3004 PDH30045 300 1800 449T 342 274 96.2 2560 21,353 PDH3006 PDH30065 300 1200 449T 347 278 95.8 2600 24,258 PDH3006L PDH30065L 300 1200 5009B 339 271 95.8 3950 28,786 PDH3008 PDH30085 300 900 5009B 366 293 94.6 4200 32,832

NOTE: (1) Prices subject to change without notice. (2) Ratings over 125HP are single voltage rated (460V). (3) For 50Hz, please contact a TWMI representative. (4) For belt drive application, please contact a TWMI representative. (5) For VFD applcations please refer to page D-18.

Motor Products - OPTIM® TEFC A - 5 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES PREMIUM EFFICIENCY TEFC SEVERE DUTY

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 230V/460V 575V 460V 575V EFF. WT. LBS PRICE PDH3502 PDH35025 350 3600 449TS 373 298 95.8 3300 27,891 PDH3502L PDH35025L 350 3600 5009A - - - - 31,887 PDH3504 PDH35045 350 1800 449T 399 319 96.2 2700 24,250 PDH3504L PDH35045L 350 1800 5009B 379 303 96.2 3500 27,449 PDH3506 PDH35065 350 1200 5011B 393 314 95.8 4650 33,553 PDH3508 PDH35085 350 900 5011B 426 341 94.8 4800 37,567 PDH4002 PDH40025 400 3600 5009A 427 342 95.8 3450 33,009 PDH4004 PDH40045 400 1800 5009B 433 346 96.2 3700 29,229 PDH4006 PDH40065 400 1200 5011B 449 359 95.8 4900 38,001 PDH4008 PDH40085 400 900 5808B 478 382 94.8 5100 47,640 PDH4502 PDH45025 450 3600 5011A 480 384 95.8 4200 37,229 PDH4504 PDH45045 450 1800 5011B 487 390 96.2 4800 34,401 PDH4506 PDH45065 450 1200 5808B 500 400 95.8 5250 43,788 PDH4508 PDH45085 450 900 5808B 537 430 95.0 5450 50,382 PDH5002 PDH50025 500 3600 5011A 533 426 95.8 4600 39,866 PDH5004 PDH50045 500 1800 5011B 541 433 96.2 5000 38,224 PDH5006 PDH50065 500 1200 5808B 555 444 95.8 5600 47,462 PDH5008 PDH50085 500 900 5810B 596 477 95.2 6000 55,709 PDH6002 PDH60025 600 3600 5810A 650 520 95.4 6000 46,793 PDH6004 PDH60045 600 1800 5808B 654 523 95.5 5800 45,192 PDH6006 PDH60065 600 1200 5810B 677 542 95.6 6400 53,621 PDH6008 PDH60085 600 900 6808B 700 560 95.5 8050 65,715 PDH7002 PDH70025 700 3600 5810A 758 606 95.5 6600 53,083 PDH7004 PDH70045 700 1800 5810B 762 610 95.6 6800 52,074 PDH7006 PDH70065 700 1200 5810B 788 630 95.8 6900 62,016 PDH7008 PDH70085 700 900 6808B 816 653 95.6 8500 73,339 PDH8002 PDH80025 800 3600 6808A 865 692 95.6 8480 73,551 PDH8004 PDH80045 800 1800 5810B 866 693 95.6 7250 59,002 PDH8006 PDH80065 800 1200 6808B 897 718 96.0 8000 71,341 PDH8008 PDH80085 800 900 6808B 933 746 95.6 8850 76,830

NOTE: (1) Prices subject to change without notice. (2) Ratings over 125HP are single voltage rated (460V). (3) For 50Hz, please contact a TWMI representative. (4) For belt drive application, please contact a TWMI representative. (5) For VFD applcations please refer to page D-18. (5) RU logo for 449 Frames and Below.

Motor Products - OPTIM® TEFC A - 6 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 IEEE READY FEATURES

MODEL: ADVANTAGE PLUS IEEE READY TYPE: AEHH8R Effective 05-01-18 Supercedes All Previous

APPLICATIONS • Fans & Blowers • Compressors • Any Severe Duty / Petro-Chemical / Pulp & Paper Applications • Pumps • Mixers • Class II Applications Such as Sawmills • Crushers • Conveyors

PRODUCT OVERVIEW • 1-100HP • 3600, 1800, 1200 & 900RPM • Horizontal F1 Mount • 60Hz, 460V or 575V • Totally Enclosed IP55 Design • NEMA Premium Efficiency

DESIGN FEATURES • 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power • 40˚C Ambient • Continuous Duty • Max Elevation 3300ft • Class F Insulation • NEMA Design B or C

MECHANICAL FEATURES • C3 Clearance Open Bearings with Regreaseable Provisions • Polyrex EM Grease • Aluminum Rotor • Cast-Iron Frame and End Brackets • Cast-Iron Conduit Box • Non-Sparking Plastic Fan • Number of Leads 460V/575V: 3 Leads; Solderless Lug Terminals on All Leads • Grounding Terminal Inside Main Terminal Box and Provisions for Grounding Terminal on Motor Frame • Interchangeable F1 and F2 mounting • Dual Drilled Feet for Longer Frames (i.e. 145T also Drilled for 143T) • Paint System: Zinc Chromate Epoxy Primer, Phenolic Rust Proof Base with Lacquer Top Coat • Stainless Steel Hardware, Breather Drains and Nameplate • Rubber Flinger on DE up to 280T; Copper Flinger on Both Ends 280TS and Larger • *HPE™ High Pulse Endurance Spike Resistant Wire • 2 Dips Phenolic Alkyd Resin Varnish with Moisture Resistant Varnish • Bi-Directional Rotation

OTHER FEATURES • CSA Certified for Class I, Division 2, Groups B, C & D (Class I, Zone 2, Groups IIB+H2, IIB and IIA) • CSA Certified for Class II, Division 2, Groups F & G (Zone 22, Groups IIIA & IIIB) • *Speed Ranges up to 10:1 CT, and 20:1 VT. Refer to data sheet for rating specific turn down ratios • *Meets NEMA MG1 Part 31.4.4.2

* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.

Motor Products - ADVANTAGE PLUS IEEE READY A - 7 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 IEEE READY LIST PRICES PREMIUM EFFICIENCY TEFC SEVERE DUTY

Effective 05-01-18 TYPE: AEHH8R Supercedes All Previous VOLTAGE: 460V

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 460V 575V 460V 575V EFF. WT. LBS PRICE APH0012 APH00125 1 3600 143T 1.34 1.07 82.5 46 368 APH0014 APH00145 1 1800 143T 1.50 1.20 85.5 46 341 APH0016 APH00165 1 1200 145T 1.73 1.38 82.5 62 414 APH0018 APH00185 1 900 182T 2.08 1.66 77.0 95 757 APH1/52 APH1/525 1.5 3600 143T 2.00 1.60 84.0 46 368 APH1/54 APH1/545 1.5 1800 145T 2.08 1.66 86.5 62 382 APH1/56 APH1/565 1.5 1200 182T 2.53 2.02 87.5 84 459 APH1/58 APH1/585 1.5 900 184T 3.01 2.41 77.0 114 846 APH0022 APH00225 2 3600 145T 2.52 2.02 86.5 62 395 APH0024 APH00245 2 1800 145T 2.78 2.22 86.5 62 424 APH0026 APH00265 2 1200 184T 3.00 2.40 88.5 101 527 APH0028 APH00285 2 900 213T 3.42 2.74 85.5 167 992 APH0032 APH00325 3 3600 182T 3.53 2.82 88.5 84 463 APH0034 APH00345 3 1800 182T 3.74 2.99 89.5 84 477 APH0036 APH00365 3 1200 213T 4.02 3.22 89.5 167 683 APH0038 APH00385 3 900 215T 4.98 3.98 85.5 189 1,298 APH0052 APH00525 5 3600 184T 5.72 4.58 88.5 101 586 APH0054 APH00545 5 1800 184T 6.12 4.90 89.5 101 551 APH0056 APH00565 5 1200 215T 6.24 4.99 91.0 194 939 APH0058 APH00585 5 900 254T 7.52 6.02 86.5 288 1,555 APH7/52 APH7/525 7.5 3600 213T 8.67 6.94 91.0 167 739 APH7/54 APH7/545 7.5 1800 213T 8.85 7.08 91.7 167 747 APH7/56 APH7/565 7.5 1200 254T 9.59 7.67 91.0 297 1,227 APH7/58 APH7/585 7.5 900 256T 11.5 9.20 85.5 332 2,236 APH0102 APH01025 10 3600 215T 11.5 9.20 91.0 194 878 APH0104 APH01045 10 1800 215T 11.6 9.28 91.7 194 901 APH0106 APH01065 10 1200 256T 12.8 10.2 91.0 337 1,520 APH0108 APH01085 10 900 284T 14.2 11.4 89.5 429 2,586 APH0152 APH01525 15 3600 254T 16.6 13.3 92.4 297 1,208 APH0154 APH01545 15 1800 254T 17.3 13.8 92.4 297 1,208 APH0156 APH01565 15 1200 284T 18.2 14.6 92.4 418 2,057 APH0158 APH01585 15 900 286T 20.1 16.1 89.5 475 3,518 APH0202 APH02025 20 3600 256T 21.9 17.5 92.4 337 1,537 APH0204 APH02045 20 1800 256T 23.0 18.4 93.0 337 1,520 APH0206 APH02065 20 1200 286T 24.3 19.4 91.7 475 2,448 APH0208 APH02085 20 900 324T 25.6 20.5 90.2 664 3,932 APH0252 APH02525 25 3600 284TS 27.8 22.2 92.4 394 1,908 APH0254 APH02545 25 1800 284T 29.1 23.3 93.6 418 1,863 APH0256 APH02565 25 1200 324T 30.3 24.2 93.0 638 3,108 APH0258 APH02585 25 900 326T 32.6 26.1 90.2 724 4,804 APH0302 APH03025 30 3600 286TS 33.2 26.6 93.0 444 2,248 APH0304 APH03045 30 1800 286T 34.3 27.4 93.6 475 2,203 APH0306 APH03065 30 1200 326T 37.5 30.0 93.0 675 3,685 APH0308 APH03085 30 900 364T 39.0 31.2 93.0 898 5,085

NOTE: (1) Prices subject to change without notice. (2) For ratings meeting NEMA Design C, please contact a TWMI representative. (3) For belt drive application, please contact a TWMI representative. (4) For VFD applcations please refer to page D-18.

Motor Products - ADVANTAGE PLUS IEEE READY A - 8 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 IEEE READY LIST PRICES PREMIUM EFFICIENCY TEFC SEVERE DUTY

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 460V 575V 460V 575V EFF. WT. LBS PRICE APH0402 APH04025 40 3600 324TS 44.2 35.4 94.1 616 2,956 APH0404 APH04045 40 1800 324T 46.3 37.0 94.1 638 2,942 APH0406 APH04065 40 1200 364T 46.0 36.8 94.1 834 4,938 APH0408 APH04085 40 900 365T 53.4 42.7 91.7 928 7,597 APH0502 APH05025 50 3600 326TS 54.7 43.8 94.1 638 4,008 APH0504 APH05045 50 1800 326T 56.9 45.5 94.5 675 3,600 APH0506 APH05065 50 1200 365T 57.8 46.2 94.1 913 5,748 APH0508 APH05085 50 900 404T 62.5 50.0 93.0 1166 8,912 APH0602 APH06025 60 3600 364TS 64.2 51.4 94.1 759 5,312 APH0604 APH06045 60 1800 364T 68.4 54.7 95.0 834 5,214 APH0606 APH06065 60 1200 404T 68.3 54.6 94.5 1166 6,631 APH0608 APH06085 60 900 405T 74.6 59.7 93.0 1298 9,775 APH0752 APH07525 75 3600 365TS 79.9 63.9 94.5 818 6,669 APH0754 APH07545 75 1800 365T 85.1 68.1 95.4 913 6,439 APH0756 APH07565 75 1200 405T 85.9 68.7 94.5 1298 7,930 APH1002 APH10025 100 3600 405TS 107 85.6 95.4 1144 8,957 APH1004 APH10045 100 1800 405T 112 89.6 95.4 1298 8,312

NOTE: (1) Prices subject to change without notice. (2) For ratings meeting NEMA Design C, please contact a TWMI representative. (3) For belt drive application, please contact a TWMI representative. (4) For VFD applcations please refer to page D-18.

Motor Products - ADVANTAGE PLUS IEEE READY A - 9 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 IEEE 841 FEATURES

MODEL: ADVANTAGE PLUS IEEE 841 TYPE: AEHH8B Effective 05-01-18 Supercedes All Previous

APPLICATIONS • Fans & Blowers • Compressors • Any Severe Duty / Petro-Chemical / Pulp & Paper Applications • Pumps • Mixers • Crushers • Conveyors

PRODUCT OVERVIEW • 1-500HP • Horizontal F1 Mount • 3600, 1800, 1200 & 900RPM • 60Hz, 460V or 575V • NEMA Premium Efficiency • Totally Enclosed Fan Cooled IP56 Design

DESIGN FEATURES • 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power • NEMA Design B or C • Max Elevation 3300ft • Continuous Duty • Fully Compliant with IEEE 841 Standard • Class F Insulation • 40˚C Ambient

MECHANICAL FEATURES • C3 Clearance Open Bearings with Regreaseable Provisions • Polyrex EM Grease • Aluminum Rotor up to 5000 Frames; Copper/Copper Alloy 5800 and Larger • Vibration Signature Shipped with Motor • Cast-Iron Frame and End Brackets • Cast-Iron Conduit Box up to 449T Frames; Fabricated Steel Conduit Box 5000 Frames and Larger • Non-Sparking Plastic Fan up to 449T 4,6 & 8 Pole Motors; Bronze Fan 440TS 2 Pole Motors and 5000 Frames and Larger • Number of Leads 460V/575V: 3 Leads; Solderless Lug Terminals on All Leads • Grounding Terminal Inside Main Terminal Box and Provisions for Grounding Terminal on Motor Frame • Interchangeable F1 and F2 mounting up to 449T • Dual Drilled Feet for Longer Frames (i.e. 145T also Drilled for 143T) 449T and Below • Paint System: Zinc Chromate Epoxy Primer, Phenolic Rust Proof Base with Lacquer Top Coat • Stainless Steel Hardware, Breather Drains and Nameplate • Inpro/Seal on DE and NDE • *HPE™ High Pulse Endurance Spike Resistant Wire • 2 Dips Phenolic Alkyd Resin Varnish with Moisture Resistant Varnish • Bi-Directional Rotation Except 3600RPM Motors 5000 Frames and Larger Which are CW From NDE • Winding RTD's, Space Heaters and Provisions for Bearing RTD's Standard 5000 Frames and Larger

OTHER FEATURES • CSA Certified for Class I, Division 2, Groups B, C & D (Class I, Zone 2, Groups IIB+H2, IIB and IIA) • CSA Certified Class II, Division 2 (Class II, Zone 22) Available for 440 Frames and Larger Upon Request • *Speed Ranges up to 10:1 CT, and 20:1 VT. Refer to Data Sheet for Rating Specific Turn Down Ratios • Meets or Exceeds *NEMA MG1 Part 31.4.4.2; IEEE Std 841™-2009

* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.

Motor Products - ADVANTAGE PLUS IEEE 841 A - 10 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 IEEE 841 LIST PRICES PREMIUM EFFICIENCY IEEE 841 SEVERE DUTY

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 460V 575V 460V 575V EFF. WT. LBS PRICE APH0012-841 APH00125-841 1 3600 143T 1.34 1.07 82.5 46 638 APH0014-841 APH00145-841 1 1800 143T 1.50 1.20 85.5 46 604 APH0016-841 APH00165-841 1 1200 145T 1.73 1.38 82.5 62 732 APH0018-841 APH00185-841 1 900 182T 2.08 1.66 77.0 95 937 APH1/52-841 APH1/525-841 1.5 3600 143T 2.00 1.60 84.0 46 676 APH1/54-841 APH1/545-841 1.5 1800 145T 2.08 1.66 86.5 62 668 APH1/56-841 APH1/565-841 1.5 1200 182T 2.53 2.02 87.5 84 774 APH1/58-841 APH1/585-841 1.5 900 184T 3.01 2.41 77.0 114 1,022 APH0022-841 APH00225-841 2 3600 145T 2.52 2.02 86.5 62 719 APH0024-841 APH00245-841 2 1800 145T 2.78 2.22 86.5 62 706 APH0026-841 APH00265-841 2 1200 184T 3.00 2.40 88.5 101 867 APH0028-841 APH00285-841 2 900 213T 3.42 2.74 85.5 167 1,354 APH0032-841 APH00325-841 3 3600 182T 3.53 2.82 88.5 84 790 APH0034-841 APH00345-841 3 1800 182T 3.74 2.99 89.5 84 796 APH0036-841 APH00365-841 3 1200 213T 4.02 3.22 89.5 167 1,178 APH0038-841 APH00385-841 3 900 215T 4.98 3.98 85.5 189 1,503 APH0052-841 APH00525-841 5 3600 184T 5.72 4.58 88.5 101 901 APH0054-841 APH00545-841 5 1800 184T 6.12 4.90 89.5 101 883 APH0056-841 APH00565-841 5 1200 215T 6.24 4.99 91.0 194 1,439 APH0058-841 APH00585-841 5 900 254T 7.52 6.02 86.5 288 2,024 APH7/52-841 APH7/525-841 7.5 3600 213T 8.67 6.94 91.0 167 1,143 APH7/54-841 APH7/545-841 7.5 1800 213T 8.85 7.08 91.7 167 1,156 APH7/56-841 APH7/565-841 7.5 1200 254T 9.59 7.67 91.0 297 1,934 APH7/58-841 APH7/585-841 7.5 900 256T 11.5 9.20 85.5 332 2,526 APH0102-841 APH01025-841 10 3600 215T 11.5 9.20 91.0 194 1,265 APH0104-841 APH01045-841 10 1800 215T 11.6 9.28 91.7 194 1,285 APH0106-841 APH01065-841 10 1200 256T 12.8 10.2 91.0 337 2,182 APH0108-841 APH01085-841 10 900 284T 14.2 11.4 89.5 429 3,046 APH0152-841 APH01525-841 15 3600 254T 16.6 13.3 92.4 297 1,745 APH0154-841 APH01545-841 15 1800 254T 17.3 13.8 92.4 297 1,754 APH0156-841 APH01565-841 15 1200 284T 18.2 14.6 92.4 418 2,946 APH0158-841 APH01585-841 15 900 286T 20.1 16.1 89.5 475 3,876 APH0202-841 APH02025-841 20 3600 256T 21.9 17.5 92.4 337 2,283 APH0204-841 APH02045-841 20 1800 256T 23.0 18.4 93.0 337 2,224 APH0206-841 APH02065-841 20 1200 286T 24.3 19.4 91.7 475 3,571 APH0208-841 APH02085-841 20 900 324T 25.6 20.5 90.2 664 4,389 APH0252-841 APH02525-841 25 3600 284TS 27.8 22.2 92.4 394 2,732 APH0254-841 APH02545-841 25 1800 284T 29.1 23.3 93.6 418 2,533 APH0256-841 APH02565-841 25 1200 324T 30.3 24.2 93.0 638 3,920 APH0258-841 APH02585-841 25 900 326T 32.6 26.1 90.2 724 5,221 APH0302-841 APH03025-841 30 3600 286TS 33.2 26.6 93.0 444 3,047 APH0304-841 APH03045-841 30 1800 286T 34.3 27.4 93.6 475 2,804 APH0306-841 APH03065-841 30 1200 326T 37.5 30.0 93.0 675 4,302 APH0308-841 APH03085-841 30 900 364T 39.0 31.2 93.0 898 6,713

NOTE: (1) Prices subject to change without notice. (2) For ratings meeting NEMA Design C, please contact a TWMI representative. (3) For belt drive application, please contact a TWMI representative. (4) For VFD applcations please refer to page D-18.

Motor Products - ADVANTAGE PLUS IEEE 841 A - 11 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 IEEE 841 LIST PRICES PREMIUM EFFICIENCY IEEE 841 SEVERE DUTY

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 460V 575V 460V 575V EFF. WT. LBS PRICE APH0402-841 APH04025-841 40 3600 324TS 44.2 35.4 94.1 616 3,589 APH0404-841 APH04045-841 40 1800 324T 46.3 37.0 94.1 638 3,457 APH0406-841 APH04065-841 40 1200 364T 46.0 36.8 94.1 834 5,821 APH0408-841 APH04085-841 40 900 365T 53.4 42.7 91.7 928 8,428 APH0502-841 APH05025-841 50 3600 326TS 54.7 43.8 94.1 638 4,596 APH0504-841 APH05045-841 50 1800 326T 56.9 45.5 94.5 675 4,131 APH0506-841 APH05065-841 50 1200 365T 57.8 46.2 94.1 913 6,727 APH0508-841 APH05085-841 50 900 404T 62.5 50.0 93.0 1166 9,805 APH0602-841 APH06025-841 60 3600 364TS 64.2 51.4 94.1 759 6,246 APH0604-841 APH06045-841 60 1800 364T 68.4 54.7 95.0 834 6,043 APH0606-841 APH06065-841 60 1200 404T 68.3 54.6 94.5 1166 7,746 APH0608-841 APH06085-841 60 900 405T 74.6 59.7 93.0 1298 10,727 APH0752-841 APH07525-841 75 3600 365TS 79.9 63.9 94.5 818 7,247 APH0754-841 APH07545-841 75 1800 365T 85.1 68.1 95.4 913 6,997 APH0756-841 APH07565-841 75 1200 405T 85.9 68.7 94.5 1298 9,137 APH0758-841 APH07585-841 75 900 444T 95.6 76.5 93.0 1600 12,685 APH1002-841 APH10025-841 100 3600 405TS 107 85.6 95.4 1144 9,733 APH1004-841 APH10045-841 100 1800 405T 112 89.6 95.4 1298 9,032 APH1006-841 APH10065-841 100 1200 444T 119 95.2 95.0 1600 12,044 APH1008-841 APH10085-841 100 900 445T 127 102 93.0 1800 15,604 APH1252-841 APH12525-841 125 3600 444TS 143 114 95.0 1600 12,901 APH1254-841 APH12545-841 125 1800 444T 146 117 95.4 1600 11,582 APH1256-841 APH12565-841 125 1200 445T 148 118 95.0 1700 14,740 APH1258-841 APH12585-841 125 900 447T 156 125 93.6 2450 18,905 APH1502-841 APH15025-841 150 3600 445TS 170 136 95.0 1700 15,421 APH1504-841 APH15045-841 150 1800 445T 175 140 95.8 1780 13,339 APH1506-841 APH15065-841 150 1200 447T 176 141 95.8 2170 17,419 APH1508-841 APH15085-841 150 900 449T 188 150 93.6 2800 22,776 APH2002-841 APH20025-841 200 3600 447TS 226 181 95.4 1900 18,775 APH2004-841 APH20045-841 200 1800 447T 230 184 96.2 2220 16,229 APH2006-841 APH20065-841 200 1200 449T 233 186 95.8 2450 21,328 APH2008-841 APH20085-841 200 900 449T 249 199 94.0 3200 26,927 APH2502-841 APH25025-841 250 3600 449TS 278 222 95.8 2320 22,501 APH2504-841 APH25045-841 250 1800 449T 285 228 96.2 2450 20,164 APH2506-841 APH25065-841 250 1200 449T 289 231 95.8 2560 26,385 APH2508-841 APH25085-841 250 900 5009B 306 245 93.5 4100 41,227 APH3002-841 APH30025-841 300 3600 449TS 333 266 95.8 2550 29,279 APH3004-841 APH30045-841 300 1800 449T 342 274 96.2 2560 25,904 APH3006-841 APH30065-841 300 1200 449T 347 278 95.8 2600 32,629 APH3006L-841 APH30065L-841 300 1200 5009B 339 271 95.8 3950 40,705 APH3008-841 APH30085-841 300 900 5009B 366 293 94.6 4200 42,940 APH3502-841 APH35025-841 350 3600 449TS 373 298 95.8 3300 TBA APH3502L-841 APH35025L-841 350 3600 5009A - - - - 43,442 APH3504-841 APH35045-841 350 1800 449T 399 319 96.2 2700 33,445 APH3504L-841 APH35045L-841 350 1800 5009B 379 303 96.2 3500 39,078 APH3506-841 APH35065-841 350 1200 5011B 393 314 95.8 4650 46,531 APH3508-841 APH35085-841 350 900 5011B 426 341 94.8 4800 51,032

NOTE: (1) Prices subject to change without notice. (2) For ratings meeting NEMA Design C, please contact a TWMI representative. (3) For belt drive application, please contact a TWMI representative. (4) For VFD applcations please refer to page D-18.

Motor Products - ADVANTAGE PLUS IEEE 841 A - 12 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 IEEE 841 LIST PRICES PREMIUM EFFICIENCY IEEE 841 SEVERE DUTY

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 460V 575V 460V 575V EFF. WT. LBS PRICE APH4002-841 APH40025-841 400 3600 5009A 427 342 95.8 3450 46,183 APH4004-841 APH40045-841 400 1800 5009B 433 346 96.2 3700 42,284 APH4006-841 APH40065-841 400 1200 5011B 449 359 95.8 4900 51,789 APH4008-841 APH40085-841 400 900 5808B 478 382 94.8 5100 60,275 APH4502-841 APH45025-841 450 3600 5011A 480 384 95.8 4200 51,668 APH4504-841 APH45045-841 450 1800 5011B 487 390 96.2 4800 47,419 APH4506-841 APH45065-841 450 1200 5808B 500 400 95.8 5250 59,737 APH4508-841 APH45085-841 450 900 5808B 537 430 95.0 5450 65,823 APH5002-841 APH50025-841 500 3600 5011A 533 426 95.8 4600 56,907 APH5004-841 APH50045-841 500 1800 5011B 541 433 96.2 5000 51,551 APH5006-841 APH50065-841 500 1200 5808B 555 444 95.8 5600 65,923 APH5008-841 APH50085-841 500 900 5810B 596 477 95.2 6000 71,447

NOTE: (1) Prices subject to change without notice. (2) For ratings meeting NEMA Design C, please contact a TWMI representative. (3) For belt drive application, please contact a TWMI representative. (4) For VFD applcations please refer to page D-18. (5) RU logo for 449 Frames and Below.

Motor Products - ADVANTAGE PLUS IEEE 841 A - 13 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FEATURES

MODEL: OPTIM® TEXP TYPE: AEHHXU, AEHHXF, AEHHXV Effective 05-01-18 Supercedes All Previous

APPLICATIONS • Applications Where Explosive Gases are Present • Grain Elevators • Pumps • Applications Where Explosive Dusts / Grains are Present • Blowers

PRODUCT OVERVIEW • 1-400HP • Horizontal F1 Mount • 60Hz, 230V/460V, 460V or 575V • 3600, 1800, 1200 & 900 RPM • NEMA Premium Efficiency • Totally Enclosed Fan Cooled - Explosion Proof Design

DESIGN FEATURES • 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power • Class F Insulation • 40˚C Ambient • Continuous Duty • NEMA Design B or C • Max Elevation 3300ft

MECHANICAL FEATURES • Shielded Ball Bearings Frames 140T-280T and Open Bearings with Regreaseable Provisions Frames 280TS, 320T and Larger • Polyrex EM Grease in all Regreaseable Bearings, Multemp SRL Grease in Shielded Bearings • Aluminum Rotor up to 449T Frames; Copper/Copper Alloy 5000 and Larger • Cast-Iron Frame, Fan Cover and End Brackets • Frame Provided with Two Threaded Drain Holes and Stainless Steel Breather Drains • Cast-Iron Frame, Fan Cover, Conduit Box and End Brackets • Non-Sparking Plastic or Aluminum Fan • Number of Leads 230/460V: 9 Leads 1-5HP; 12 Leads 7.5-125HP; 6 Leads 150HP and Larger • Number of Leads 575V: 3 Leads • Solderless Lug Terminals on All Leads • Grounding Terminal Inside Main Terminal Box • Interchangeable F1 and F2 Mounting up to 449T • Paint System: Phenolic Rust Proof Base with Lacquer Top Coat • Stainless Steel Nameplate • Brass Flinger on Both Ends • *HPE™ High Pulse Endurance Spike Resistant Wire • Phenolic Alkyd Resin Varnish • Klixon 9700K Thermostats – 1 per phase

OTHER FEATURES • CSA/UL Certified for Class I, Division 1, Groups **C & D (Class I, Zone 1 Groups **IIB & IIA); and Class II, Division 1, Groups E, F & G • *Speed Ranges up to 10:1 CT, and 20:1 VT. Refer to data sheet for rating specific turn down ratios • *Meets NEMA MG1 Part 31.4.4.2

* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4. ** Up to 256T

Motor Products - OPTIM® TEXP A - 14 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES PREMIUM EFFICIENCY TEXP

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 230V/460V 575V 460V 575V EFF. WT. LBS PRICE XC0014 XC00145 1 1800 143T 1.61 1.29 85.5 62 465 XC0016 XC00165 1 1200 145T 1.72 1.38 82.5 70 519 XC0018 XC00185 1 900 182T 2.08 1.66 77.0 108 749 XC1/52 XC1/525 1.5 3600 143T 1.99 1.59 84.0 62 511 XC1/54 XC1/545 1.5 1800 145T 2.15 1.72 86.5 70 511 XC1/56 XC1/565 1.5 1200 182T 2.55 2.04 87.5 108 587 XC1/58 XC1/585 1.5 900 184T 2.96 2.37 78.5 120 847 XC0022 XC00225 2 3600 145T 2.52 2.01 85.5 70 540 XC0024 XC00245 2 1800 145T 2.78 2.22 86.5 70 524 XC0026 XC00265 2 1200 184T 3.07 2.45 88.5 120 667 XC0028 XC00285 2 900 213T 3.48 2.79 84.0 187 1,034 XC0032 XC00325 3 3600 182T 3.57 2.85 87.5 108 603 XC0034 XC00345 3 1800 182T 3.87 3.10 89.5 108 612 XC0036 XC00365 3 1200 213T 3.92 3.14 89.5 187 889 XC0038 XC00385 3 900 215T 4.98 3.98 85.5 211 1,309 XC0052 XC00525 5 3600 184T 5.81 4.65 88.5 120 704 XC0054 XC00545 5 1800 184T 6.23 4.98 89.5 120 704 XC0056 XC00565 5 1200 215T 6.41 5.13 90.2 211 1,093 XC0058 XC00585 5 900 254T 7.52 6.01 86.5 330 1,892 XC7/52 XC7/525 7.5 3600 213T 9.02 7.22 89.5 187 906 XC7/54 XC7/545 7.5 1800 213T 8.85 7.08 91.7 187 1,014 XC7/56 XC7/565 7.5 1200 254T 9.41 7.53 91.0 330 1,342 XH7/58 XH7/585 7.5 900 256T 11.4 9.08 86.5 376 2,603 XC0102 XC01025 10 3600 215T 11.9 9.55 90.2 211 1,069 XC0104 XC01045 10 1800 215T 11.7 9.34 91.7 211 1,182 XC0106 XC01065 10 1200 256T 12.6 10.1 91.0 376 1,646 XH0108 XH01085 10 900 284T 14.2 11.4 89.5 488 3,215 XC0152 XC01525 15 3600 254T 16.8 13.4 91.0 330 1,323 XC0154 XC01545 15 1800 254T 17.9 14.3 92.4 330 1,509 XH0156 XH01565 15 1200 284T 18.5 14.8 91.7 488 2,247 XH0158 XH01585 15 900 286T 20.1 16.1 89.5 530 3,409 XC0202 XC02025 20 3600 256T 22.4 17.9 91.0 376 1,756 XC0204 XC02045 20 1800 256T 23.6 18.8 93.0 376 1,807 XH0206 XH02065 20 1200 286T 24.3 19.4 91.7 530 2,670 XH0208 XH02085 20 900 324T 25.6 20.5 90.2 708 3,978 XH0252 XH02525 25 3600 284TS 27.7 22.2 91.7 466 2,267 XH0254 XH02545 25 1800 284T 29.4 23.5 93.6 488 2,293 XH0256 XH02565 25 1200 324T 30.3 24.3 93.0 708 3,219 XH0258 XH02585 25 900 326T 32.6 26.1 90.2 781 4,504 XH0302 XH03025 30 3600 286TS 33.0 26.4 92.4 502 2,619 XH0304 XH03045 30 1800 286T 35.1 28.1 93.6 530 2,665 XH0306 XH03065 30 1200 326T 36.4 29.1 93.0 781 3,893 XH0308 XH03085 30 900 364T 39.5 31.6 91.7 946 5,285

NOTE: (1) Prices subject to change without notice. (2) Ratings over 125HP are single voltage rated (460V). (3) For 50Hz, please contact a TWMI representative. (4) Group C/IIB applies to frames 256T and below. (5) For belt drive application, please contact a TWMI representative. (6) For VFD applcations please refer to page D-18.

Motor Products - OPTIM® TEXP A - 15 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES PREMIUM EFFICIENCY TEXP

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 230V/460V 575V 460V 575V EFF. WT. LBS PRICE XH0402 XH04025 40 3600 324TS 44.3 35.4 93.0 691 3,524 XH0404 XH04045 40 1800 324T 46.6 37.2 94.1 708 3,546 XH0406 XH04065 40 1200 364T 46.3 37.0 94.1 946 4,963 XH0408 XH04085 40 900 365T 53.4 42.7 91.7 1019 6,317 XH0502 XH05025 50 3600 326TS 55.0 44.0 93.6 766 4,328 XH0504 XH05045 50 1800 326T 57.9 46.4 94.5 781 4,200 XH0506 XH05065 50 1200 365T 59.6 47.7 94.1 1019 5,637 XH0508 XH05085 50 900 404T 62.5 50.0 93.0 1287 8,972 XH0602 XH06025 60 3600 364TS 64.5 51.6 93.6 913 5,394 XH0604 XH06045 60 1800 364T 67.2 53.8 95.0 946 5,468 XH0606 XH06065 60 1200 404T 69.1 55.3 94.5 1287 6,927 XH0608 XH06085 60 900 405T 74.6 59.7 93.0 1408 9,712 XH0752 XH07525 75 3600 365TS 80.7 64.5 93.6 975 7,033 XH0754 XH07545 75 1800 365T 83.6 66.9 95.4 1019 6,554 XH0756 XH07565 75 1200 405T 85.9 68.7 94.5 1408 8,126 XH0758 XH07585 75 900 444T 95.0 76.0 93.6 1650 11,983 XH1002 XH10025 100 3600 405TS 108 86.2 94.5 1349 9,156 XH1004 XH10045 100 1800 405T 109 87.2 95.4 1408 8,126 XH1006R XH10065R 100 1200 444T 119 95.0 95.0 1650 10,679 XH1008R XH10085R 100 900 445T 127 101 93.6 1720 14,228 XH1252 XH12525 125 3600 444TS 137 110 95.0 1560 12,107 XH1254R XH12545R 125 1800 444T 139 111 95.4 1600 11,240 XH1256R XH12565R 125 1200 445T 147 117 95.0 1720 14,270 XH1258R XH12585R 125 900 447T 151 121 94.1 2500 23,604 XH1502 XH15025 150 3600 445TS 164 131 95.0 1600 14,048 XH1504R XH15045R 150 1800 445T 165 132 95.8 1780 13,658 XH1506R XH15065R 150 1200 447T 173 139 95.8 2552 19,872 XH1508R XH15085R 150 900 447T 181 145 94.1 2880 24,584 XH2002 XH20025 200 3600 447TS 221 176 95.4 2662 21,057 XH2004R XH20045R 200 1800 447T 224 179 96.2 2660 21,445 XH2006R XH20065R 200 1200 449T 230 184 95.8 2992 24,725 XH2008R XH20085R 200 900 5007B 246 197 94.5 3920 36,031 XH2502 XH25025 250 3600 449TS 272 218 95.8 2816 22,021 XH2504R XH25045R 250 1800 449T 280 224 96.2 3055 21,992 XH2506R XH25065R 250 1200 5007B 281 225 95.8 4010 39,637 XH2508R XH25085R 250 900 5009B 304 243 95.0 4360 39,586 XH3002(7) XH30025(7) 300 3600 449TS 325 260 95.8 2882 26,154 XH3004R(7) XH30045R(7) 300 1800 449T 336 268 96.2 3100 24,037 XH3006R XH30065R 300 1200 5009B 336 269 95.8 4310 42,059 XH3502(7) XH35025(7) 350 3600 5007A 389 311 95.8 1020 40,863 XH3504R(7) XH35045R(7) 350 1800 5007B 388 311 96.2 4330 42,623 XH3506R(7) XH35065R(7) 350 1200 5009B 391 313 95.8 4520 43,194 XH4002(7) XH40025(7) 400 3600 5009A 443 354 95.8 4200 44,212 XH4004R(7) XH40045R(7) 400 1800 5009B 444 355 96.2 4430 45,208

NOTE: (1) Prices subject to change without notice. (2) Ratings over 125HP are single voltage rated (460V). (3) For 50Hz, please contact a TWMI representative. (4) Group C/IIB applies to frames 256T and below. (5) For belt drive application, please contact a TWMI representative. (6) For VFD applcations please refer to page D-18. (7) This rating must be de-rated when used with VFD, please contact a TWMI representative.

Motor Products - OPTIM® TEXP A - 16 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FEATURES

MODEL: OPTIM® OILWELL TYPE: AEEAFP Effective 05-01-18 Supercedes All Previous

APPLICATIONS • Any Applications Requiring NEMA Design D Torques • Oil Well Pumps

PRODUCT OVERVIEW • 3.5-125HP • 1200 RPM • Horizontal F2 Mount • 60Hz, 460V • Totally Enclosed, IP54 Design

DESIGN FEATURES • 1.15 S.F. • Class F Insulation • 40˚C Ambient • Triple HP Ratings • Continuous Duty • NEMA Design D • Max Elevation 3300ft

MECHANICAL FEATURES • Shielded Bearings Frames 140T-280T and Open Bearings with Regreaseable Provisions Frames 280TS, 320T and Larger • Polyrex EM Grease in all Regreaseable Bearings, Multemp SRL Grease in Shielded Bearings • Aluminum Rotor • Cast-Iron Frame, Fan Cover, Conduit Box and End Brackets • Non-Sparking Plastic Fan • Number of Leads 460V: 12 Leads • Solderless Lug Terminals on All Leads • Grounding Terminal Inside Main Terminal Box and on Frame • Interchangeable F1 and F2 mounting • Paint System: Phenolic Rust Proof Base with Lacquer Top Coat • Stainless Steel Nameplate • Rubber Flinger on DE up to 280T; Steel Flinger on Both Ends 320T and Larger • Phenolic Alkyd Resin Varnish with Red Varnish Coating • Klixon 9700K Thermostats – 1 per phase

OTHER FEATURES • CSA Certified

Motor Products - OPTIM® OILWELL A - 17 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES OILWELL PUMP MOTOR

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 460V 460V EFF. WT. LBS PRICE 3.5 TR7.56 5 1200 254T 10.0 83.5 276 1,492 7.5 5 TR0106 7.5 1200 256T 13.3 84.0 314 1,751 10 7.5 TR0156 10 1200 284T 18.7 85.5 420 2,490 15 10 TR0206 15 1200 286T 24.5 86.5 468 2,748 20 15 TR0256 20 1200 324T 30.5 87.0 635 3,616 25 20 TR0306 25 1200 326T 35.5 87.5 705 4,012 30 25 TR0406 30 1200 365T 47.5 88.5 906 6,070 40 30 TR0506 40 1200 404T 57.0 89.5 1166 7,146 50 40 TR0606 50 1200 405T 68.2 90.0 1212 8,288 60 40 TR0606LR 50 1200 444T 73.4 89.0 1400 9,175 60 50 TR0756R 60 1200 445T 91.2 89.5 1550 10,999 75 60 TR1006R 75 1200 445T 121 90.0 1600 12,695 100

NOTE: (1) Prices subject to change without notice. (2) F.L. Amps & Efficiency values are for the larger HP per rating.

Motor Products - OPTIM® OILWELL A - 18 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FEATURES

MODEL: MAX-HT TYPE: AEEAGD, AEHHGD Effective 05-01-18 Supercedes All Previous

APPLICATIONS • Crushers • Impactors • Chippers/ Shredders • Ball Mills/ Rolling Mills • Any High Torque Application

PRODUCT OVERVIEW • 1-600HP • 1800, 1200 & 900 RPM • Horizontal F1 Mount • 60Hz, 230/460V, 460V or 575V • Totally Enclosed IP55 Design • NEMA Premium Efficiency (1-500HP)

DESIGN FEATURES • 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power • Class F Insulation • 40˚C Ambient • Continuous Duty • NEMA Design C or A • Max Elevation 3300ft

MECHANICAL FEATURES • Shielded Bearings Frames 140T-280T and Open Bearings with Regreaseable Provisions Frames 320T and Larger • Polyrex EM Grease in all Regreaseable Bearings, Multemp SRL Grease in Shielded Bearings • Aluminum Rotor • Cast-Iron Frame and End Brackets; Fabricated Steel Fan Cover • Cast-Iron Conduit Box up to 449 Frames; Fabricated Steel Conduit Box 5000 Frames and Larger • Non-Sparking Plastic Fan up to 449T; Aluminum Fan 5000 Frames and Larger but Cast Iron Fan for 4P • Number of Leads 230/460V: 9 Leads 1-5HP; 12 Leads 7.5-125HP; 460V: 6 Leads; 575V: 6 Leads • Solderless Lug Terminals on All Leads • Grounding Terminal Inside Main Terminal Box, Additional Grounding Terminal on Frame for 5000 Frames and Larger • High Strength AISI 4140 Shaft Material with Radius Step-Down Shaft Shoulder • Locknut and Washer on NDE for Vertical Shaft Down Applications 440 Frames and Larger • Interchangeable F1 and F2 mounting up to 449T • Dual Drilled Feet for Longer Frames (i.e. 145T also Drilled for 143T) 449T and Below • Gamma Seal on DE up to 400T; Steel Flinger on Both Ends 440T and Larger • *HPE™ High Pulse Endurance Spike Resistant Wire • Epoxy Rust Proof Base Plus Polyurethane Top Coat • Bi-directional Rotation • Stainless Steel Nameplate

OTHER FEATURES • **CSA Certified for Class I, Division 2, Groups B, C & D (Class I, Zone 2, Groups IIB+H2, IIB and IIA) • **CSA Certified for Class II Div.2 Group F & G ( Class II, Zone 22, Group IIIA, IIIB) 440 Frames and Larger • *Meets NEMA MG1 Part 31.4.4.2

* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4. ** AEHHGD Motors Only

Motor Products - MAX-HT A - 19 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES TEFC CRUSHER DUTY

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 230V/460V 575V 460V 575V EFF. WT. LBS PRICE HT0014 HT00145 1 1800 143T 1.5 1.2 85.5 55 649 HT0016 HT00165 1 1200 145T 1.7 1.4 82.5 61 787 HT0018 HT00185 1 900 182T 2.4 1.9 75.5 98 1,007 HT1/54 HT1/545 1.5 1800 145T 2.1 1.7 86.5 65 718 HT1/56 HT1/565 1.5 1200 182T 2.7 2.1 87.5 91 832 HT1/58 HT1/585 1.5 900 184T 3.4 2.8 78.5 102 1,099 HT0024 HT00245 2 1800 145T 2.8 2.2 86.5 63 759 HT0026 HT00265 2 1200 184T 3.5 2.8 88.5 102 932 HT0028 HT00285 2 900 213T 3.2 2.6 85.5 151 1,456 HT0034 HT00345 3 1800 182T 4.0 3.2 89.5 102 856 HT0036 HT00365 3 1200 213T 4.0 3.2 89.5 151 1,266 HT0038 HT00385 3 900 215T 5.0 4.0 85.5 204 1,616 HT0054 HT00545 5 1800 184T 6.4 5.1 89.5 118 949 HT0056 HT00565 5 1200 215T 6.6 5.3 91.0 204 1,547 HT0058 HT00585 5 900 254T 8.3 6.7 86.5 274 2,176 HT7/54 HT7/545 7.5 1800 213T 8.9 7.1 91.7 177 1,243 HT7/56 HT7/565 7.5 1200 254T 9.6 7.7 91.0 274 2,079 HT7/58 HT7/585 7.5 900 256T 10.8 8.7 87.5 310 2,715 HT0104 HT01045 10 1800 215T 11.6 9.3 91.7 208 1,381 HT0106 HT01065 10 1200 256T 12.8 10.2 91.0 310 2,346 HT0108 HT01085 10 900 284T 14.1 11.3 90.2 419 3,274 HT0154 HT01545 15 1800 254T 17.3 13.8 92.4 308 1,886 HT0156 HT01565 15 1200 284T 18.2 14.6 92.4 419 3,167 HT0158 HT01585 15 900 286T 20.0 16.0 90.2 478 4,167 HT0204 HT02045 20 1800 256T 23.4 18.7 93.0 339 2,391 HT0206 HT02065 20 1200 286T 24.3 19.4 91.7 510 3,839 HT0208 HT02085 20 900 324T 25.4 20.3 91.0 638 4,718 HT0254 HT02545 25 1800 284T 29.1 23.3 93.6 449 2,723 HT0256 HT02565 25 1200 324T 30.3 24.3 93.0 686 4,214 HT0258 HT02585 25 900 326T 32.2 25.7 91.0 695 5,613 HT0304 HT03045 30 1800 286T 34.3 27.4 93.6 550 3,014 HT0306 HT03065 30 1200 326T 37.5 30.0 93.0 695 4,625 HT0308 HT03085 30 900 364T 38.7 31.0 93.0 869 7,216 HT0404 HT04045 40 1800 324T 46.3 37.0 94.1 638 3,716 HT0406 HT04065 40 1200 364T 46.0 36.8 94.1 871 6,258 HT0408 HT04085 40 900 365T 51.6 41.3 93.0 913 9,060 HT0504 HT05045 50 1800 326T 56.9 45.6 94.5 737 4,441 HT0506 HT05065 50 1200 365T 57.8 46.2 94.1 895 7,232 HT0508 HT05085 50 900 404T 62.1 49.7 93.0 1208 10,540 HT0604 HT06045 60 1800 364T 68.4 54.7 95.0 845 5,984 HT0606 HT06065 60 1200 404T 68.3 54.7 94.5 1247 8,327 HT0608 HT06085 60 900 405T 74.6 59.7 93.0 1254 11,532 HT0754 HT07545 75 1800 365T 85.1 68.1 95.4 913 7,522 HT0756 HT07565 75 1200 405T 85.9 68.7 94.5 1344 9,822 HT0758 HT07585 75 900 444T 103 82.2 93.6 1628 13,636

NOTE: (1) Prices subject to change without notice. (2) For VFD applcations please refer to page D-18.

Motor Products - MAX-HT A - 20 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES TEFC CRUSHER DUTY

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 230V/460V 575V 460V 575V EFF. WT. LBS PRICE HT1004 HT10045 100 1800 405T 112 89.7 95.4 1296 9,709 HT1006 HT10065 100 1200 444T 119 95.6 95.0 1676 12,947 HT1008 HT10085 100 900 445T 128 103 93.6 1815 16,774 HT1254 HT12545 125 1800 444T 144 115 95.4 1727 12,451 HT1256 HT12565 125 1200 445T 148 119 95.0 1907 15,846 HT1258 HT12585 125 900 447T 155 124 94.1 2108 21,741 HT1258RZ HT12585RZ 125 900 447TZ 155 124 94.1 2108 21,741 HT1504 HT15045 150 1800 445T 172 138 95.8 1804 14,339 HT1506 HT15065 150 1200 447T 176 140 95.8 2178 20,032 HT1506RZ HT15065RZ 150 1200 447TZ 176 140 95.8 2178 20,032 HT1508 HT15085 150 900 449T 187 149 94.1 2486 24,484 HT1508RZ HT15085RZ 150 900 449TZ 187 149 94.1 2486 24,484 HT2004 HT20045 200 1800 447T 224 179 96.2 2134 18,663 HT2004RZ HT20045RZ 200 1800 447TZ 224 179 96.2 2134 18,663 HT2006 HT20065 200 1200 449T 233 186 95.8 2387 24,527 HT2006RZ HT20065RZ 200 1200 449TZ 233 186 95.8 2387 24,527 HT2008 HT20085 200 900 449T 240 192 94.5 2787 28,947 HT2008RZ HT20085RZ 200 900 449TZ 240 192 94.5 2787 28,947 HT2504 HT25045 250 1800 449T 286 229 96.2 2482 24,994 HT2504RZ HT25045RZ 250 1800 449TZ 286 229 96.2 2482 24,994 HT2504LR HT25045LR 250 1800 5007C 287 229 96.2 3320 33,476 HT2504LRZ HT25045LRZ 250 1800 505UZ 287 229 96.2 2910 34,767 HT2506 HT25065 250 1200 449T 311 249 95.8 2651 26,753 HT2506RZ HT25065RZ 250 1200 449TZ 311 249 95.8 2651 26,753 HT2506LR HT25065LR 250 1200 5007C 308 246 95.8 3460 29,204 HT2506LRZ HT25065LRZ 250 1200 586/7UZ 302 241 95.8 4520 34,265 HT2508R HT25085R 250 900 5009C 315 252 95.0 3890 32,337 HT2508RZ HT25085RZ 250 900 586/7UZ 309 247 95.8 4680 33,083 HT3004 HT30045 300 1800 449T 348 278 96.2 2673 28,775 HT3004RZ HT30045RZ 300 1800 449TZ 348 278 96.2 2673 28,775 HT3004LR HT30045LR 300 1800 5007C 345 276 96.2 3410 35,643 HT3004LRZ HT30045LRZ 300 1800 586/7UZ 344 275 96.2 4580 35,907 HT3006R HT30065R 300 1200 5009C 356 285 95.8 4050 34,745 HT3006RZ HT30065RZ 300 1200 586/7UZ 353 283 95.8 4650 35,862 HT3008R HT30085R 300 900 5806C 367 294 94.5 4850 34,999 HT3008RZ HT30085RZ 300 900 586/7UZ 367 294 94.5 5000 - HT3504R HT35045R 350 1800 5009C 410 328 96.2 3840 38,514 HT3504RZ HT35045RZ 350 1800 586/7UZ 395 316 96.2 4740 43,640 HT3506R HT35065R 350 1200 5806C 416 333 95.8 5000 39,498 HT3506RZ HT35065RZ 350 1200 586/7UZ 416 333 95.8 4980 40,237 HT3508R HT35085R 350 900 5808C 427 342 94.5 5250 41,064 HT3508RZ HT35085RZ 350 900 586/7UZ 433 347 94.5 5100 - HT4004R HT40045R 400 1800 5806C 463 371 96.2 4930 45,192 HT4004RZ HT40045RZ 400 1800 586/7UZ 463 371 96.2 4860 48,129 HT4006R HT40065R 400 1200 5808C 461 369 95.0 4800 44,520 HT4006RZ HT40065RZ 400 1200 586/7UZ 461 369 95.0 4650 - HT4008R HT40085R 400 900 5808C 487 389 95.0 6400 56,267 HT4008RZ HT40085RZ 400 900 586/7UZ 487 389 95.0 6400 -

NOTE: (1) Prices subject to change without notice. (2) For VFD applcations please refer to page D-18.

Motor Products - MAX-HT A - 21 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES TEFC CRUSHER DUTY

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 230V/460V 575V 460V 575V EFF. WT. LBS PRICE HT5004R HT50045R 500 1800 5808C 562 450 96.2 5560 56,723 HT5004RZ HT50045RZ 500 1800 586/7UZ 562 450 96.2 5140 57,643 HT5006R HT50065R 500 1200 5808C 574 459 95.4 5650 59,227 HT5006RZ HT50065RZ 500 1200 586/7UZ 574 459 95.4 5450 - HT6004R HT60045R 600 1800 5808C 655 524 95.8 5800 61,497 HT6004RZ HT60045RZ 600 1800 586/7UZ 655 524 95.8 5800 - HT6006R HT60065R 600 1200 5810C 689 551 95.4 6400 68,345

NOTE: (1) Prices subject to change without notice. (2) For VFD applcations please refer to page D-18.

Motor Products - MAX-HT A - 22 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FEATURES

MODEL: ROLLED STEEL ODP TYPE: ASGH/ASGHPE Effective 05-01-18 Supercedes All Previous

APPLICATIONS • Fans & Blowers • Pumps • HVAC Equipment • Compressors

PRODUCT OVERVIEW • 1/4-40HP • Open Drip Proof IP22 Design • 56/56C Frame Available 1/4-3HP • Horizontal F1 Mount • 60Hz, 230V/460V, or 575V • NEMA Premium Efficiency (T Frame) • 3600, 1800 & 1200 RPM • MEPS Efficiency (56 Frame)

DESIGN FEATURES • 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power • Class F Insulation • 40˚C Ambient • Continuous Duty • NEMA Design B • Max Elevation 3300ft

MECHANICAL FEATURES • Shielded Bearings • Multemp SRL Grease • Aluminum Rotor • Rolled Steel Frame with Cast-Iron End Brackets • Rolled Steel Conduit Box • Number of Leads 230/460V: 9 Leads 1/4-5HP; 12 Leads 7.5 and Larger; 575V: 3 Leads • Solderless Lug Terminals on All Leads • Grounding Terminal Inside Main Terminal Box • Paint System: Phenolic Rust Proof Base with Lacquer Top Coat • Stainless Steel Nameplate • 230/460V Motors Usable on 208V (Sinusoidal Power Only) • Rubber Flinger on DE • *HPE™ High Pulse Endurance Spike Resistant Wire • 56 Frame Available 1/4-3HP • Phenolic Alkyd Resin Varnish

OTHER FEATURES • *Meets NEMA MG1 Part 31.4.4.2 • *Speed Range 10:1 CT, and 20:1 VT • CSA Certified, UL recognized and CE marked • CSA Energy Efficiency Verification (EEV)

* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.

Motor Products - ROLLED STEEL ODP A - 23 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES PREMIUM EFFICIENCY ODP

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 230V/460V 575V 460V 575V EFF. WT. LBS PRICE RD0/22 RD0/225 0.25 3600 56 0.40 0.32 72.0 19 154 RD0/24 RD0/245 0.25 1800 56 0.45 0.36 72.0 20 157 RD0/26 RD0/265 0.25 1200 56 0.55 0.44 70.0 21 182 RD0/32 RD0/325 0.33 3600 56 0.53 0.42 72.0 19 162 RD0/34 RD0/345 0.33 1800 56 0.56 0.44 75.5 21 167 RD0/36 RD0/365 0.33 1200 56 0.71 0.57 72.0 25 198 RD0/52 RD0/525 0.5 3600 56 0.73 0.58 75.5 20 174 RD0/54 RD0/545 0.5 1800 56 0.83 0.66 77.0 23 179 RD0/56 RD0/565 0.5 1200 56 0.99 0.79 75.5 31 232 RD0/72 RD0/725 0.75 3600 56 1.11 0.89 78.5 22 182 RD0/74 RD0/745 0.75 1800 56 1.19 0.95 78.5 24 185 RD0/76 RD0/765 0.75 1200 56 1.24 0.99 78.5 32 271 RD0012-56 RD00125-56 1 3600 56 1.37 1.10 80.0 25 196 RD0012 RD00125 1 3600 143T 1.37 1.10 80.0 28 249 RD0014-56 RD00145-56 1 1800 56 1.45 1.16 85.5 35 235 RD0014 RD00145 1 1800 143T 1.45 1.16 85.5 35 241 RD0016-56 RD00165-56 1 1200 56 1.72 1.38 82.5 37 311 RD0016 RD00165 1 1200 145T 1.72 1.38 82.5 36 286 RD1/52-56 RD1/525-56 1.5 3600 56 1.98 1.58 85.5 26 243 RD1/52 RD1/525 1.5 3600 143T 1.91 1.53 85.5 28 268 RD1/54-56 RD1/545-56 1.5 1800 56 2.00 1.60 86.5 36 297 RD1/54 RD1/545 1.5 1800 145T 2.00 1.60 86.5 40 265 RD1/56-56 RD1/565-56 1.5 1200 56 3.01 2.41 86.5 39 340 RD1/56 RD1/565 1.5 1200 182T 3.01 2.41 86.5 68 331 RD0022-56 RD00225-56 2 3600 56 2.46 1.97 86.5 29 269 RD0022 RD00225 2 3600 145T 2.46 1.97 86.5 35 296 RD0024-56 RD00245-56 2 1800 56 2.61 2.09 86.5 38 322 RD0024 RD00245 2 1800 145T 2.61 2.09 86.5 44 286 RD0026 RD00265 2 1200 184T 3.75 3.00 87.5 68 402 RD0032-56 RD00325-56 3 3600 56 3.91 3.13 86.5 35 307 RD0032 RD00325 3 3600 145T 3.91 3.13 85.5 35 323 RD0034-56 RD00345-56 3 1800 56 4.30 3.44 89.5 42 346 RD0034 RD00345 3 1800 182T 4.30 3.44 89.5 60 331 RD0036 RD00365 3 1200 213T 4.60 3.68 88.5 95 569

NOTE: (1) Prices subject to change without notice. (2) For VFD applcations please refer to page D-18.

Motor Products - ROLLED STEEL ODP A - 24 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES PREMIUM EFFICIENCY ODP

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 230V/460V 575V 460V 575V EFF. WT. LBS PRICE RD0052 RD00525 5 3600 182T 6.08 4.86 87.5 67 396 RD0054 RD00545 5 1800 184T 6.79 5.43 89.5 77 402 RD0056 RD00565 5 1200 215T 7.17 5.73 89.5 123 681 RD7/52 RD7/525 7.5 3600 184T 8.82 7.05 88.5 77 484 RD7/54 RD7/545 7.5 1800 213T 9.53 7.62 91.0 115 569 RD7/56 RD7/565 7.5 1200 254T 10.11 8.09 90.2 197 901 RD0102 RD01025 10 3600 213T 12.14 9.71 90.2 123 616 RD0104 RD01045 10 1800 215T 12.16 9.72 91.7 143 681 RD0106 RD01065 10 1200 256T 12.84 10.28 91.7 234 1,099 RD0152 RD01525 15 3600 215T 17.74 14.19 91.0 152 810 RD0154 RD01545 15 1800 254T 18.20 14.56 93.0 213 901 RD0156 RD01565 15 1200 284T 19.15 15.32 91.7 305 1,421 RD0202 RD02025 20 3600 254T 22.69 18.15 91.7 202 1,048 RD0204 RD02045 20 1800 256T 24.26 19.41 93.0 234 1,099 RD0206 RD02065 20 1200 286T 24.71 19.77 92.4 364 1,699 RD0252 RD02525 25 3600 256T 28.05 22.44 91.7 202 1,261 RD0254 RD02545 25 1800 284T 29.42 23.54 93.6 295 1,449 RD0302 RD03025 30 3600 284TS 33.78 27.02 92.4 273 1,554 RD0304 RD03045 30 1800 286T 34.71 27.77 94.1 346 1,658 RD0402 RD04025 40 3600 286TS 44.79 35.83 92.4 322 1,917

NOTE: (1) Prices subject to change without notice. (2) For VFD applcations please refer to page D-18.

Motor Products - ROLLED STEEL ODP A - 25 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FEATURES

MODEL: OPTIM® ODP TYPE: ASHH Effective 05-01-18 Supercedes All Previous

APPLICATIONS • Fans & Blowers • Compressors • Pumps

PRODUCT OVERVIEW • 1-500HP • Open Drip Proof IP22 Design • 60Hz, 230V/460V, 460V or 575V • Horizontal F1 Mount • 3600, 1800 & 1200 RPM • NEMA Premium Efficiency (250-500HP)

DESIGN FEATURES • 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power • Class F Insulation • 40˚C Ambient • Continuous Duty • NEMA Design B • Max Elevation 3300ft

MECHANICAL FEATURES • Shielded Bearings Frames 140T-280T and Open Bearings with Regreaseable Provisions Frames 280TS, 320T and Larger • Polyrex EM Grease in all Regreaseable Bearings, Multemp SRL Grease in Shielded Bearings • Aluminum Rotor • Cast-Iron Frame and End Brackets • Rolled Steel Conduit Box up to 400T Frames; Fabricated Steel Conduit Box 440T Frames and Larger • Number of Leads 230/460V: 9 Leads 1-5HP; 12 Leads 7.5-125HP; 6 Leads 150 and Above • Number of Leads 575V: 3 Leads up to 449T; 6 Leads 5000 Frames and Larger • Solderless Lug Terminals on All Leads • Grounding Terminal Inside Main Terminal Box • Interchangeable F1 and F2 mounting up to 449T • Paint System: Phenolic Rust Proof Base with Lacquer Top Coat • Stainless Steel Nameplate • Usable on 208V Sinusoidal Power Only • Rubber Flinger on DE up to 280T; Steel Flinger on DE 280TS and Larger • *HPE™ High Pulse Endurance Spike Resistant Wire • Phenolic Alkyd Resin Varnish 140T to 400T Frames; 2 Dips Phenolic Alkyd Resin Varnish and 1 Coat Spray Enamel 440T Frames and Larger • Winding RTD's, Space Heaters and Provisions for Bearing RTD's Standard 5000 Frames and Larger

OTHER FEATURES • CSA Certified, UL Recognized and CE Marked • UL Listed (UL 1004-5) for Fire Pump Applications (1-400HP) • CSA Energy Efficiency Verification (EEV) • *Meets NEMA MG1 Part 31.4.4.2 • *Speed Ranges up to 10:1 CT, and 20:1 VT. Refer to data sheet for rating specific turn down ratios

* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.

Motor Products - OPTIM® ODP A - 26 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES NEMA PREMIUM EFFICIENCY OPEN DRIP PROOF

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 230V/460V 575V 460V 575V EFF. WT. LBS PRICE SDP0014 SDP00145 1 1800 143T 1.40 1.12 85.5 53 266 SDP0016 SDP00165 1 1200 145T 1.74 1.39 82.5 66 329 SDP1/52 SDP1/525 1.5 3600 143T 2.06 1.64 85.5 53 266 SDP1/54 SDP1/545 1.5 1800 145T 2.02 1.61 86.5 66 278 SDP1/56 SDP1/565 1.5 1200 182T 2.55 2.04 87.5 95 358 SDP0022 SDP00225 2 3600 145T 2.59 2.07 85.5 66 301 SDP0024 SDP00245 2 1800 145T 2.72 2.18 86.5 66 288 SDP0026 SDP00265 2 1200 184T 3.01 2.41 87.5 106 435 SDP0032 SDP00325 3 3600 145T 3.69 2.95 87.5 66 322 SDP0034 SDP00345 3 1800 182T 3.88 3.10 89.5 95 334 SDP0036 SDP00365 3 1200 213T 4.12 3.30 88.5 159 545 SDP0052 SDP00525 5 3600 182T 5.90 4.72 87.5 95 395 SDP0054 SDP00545 5 1800 184T 6.19 4.95 89.5 106 418 SDP0056 SDP00565 5 1200 215T 6.62 5.30 89.5 185 692 SDP7/52 SDP7/525 7.5 3600 184T 8.65 6.92 88.5 106 489 SDP7/54 SDP7/545 7.5 1800 213T 8.97 7.18 91.0 159 572 SDP7/56 SDP7/565 7.5 1200 254T 9.85 7.88 90.2 247 953 SDP0102 SDP01025 10 3600 213T 11.8 9.44 90.2 159 608 SDP0104 SDP01045 10 1800 215T 11.7 9.39 91.7 185 712 SDP0106 SDP01065 10 1200 256T 12.6 10.1 91.7 287 1,083 SDP0152 SDP01525 15 3600 215T 17.8 14.2 90.2 185 827 SDP0154 SDP01545 15 1800 254T 17.9 14.3 93.0 247 991 SDP0156 SDP01565 15 1200 284T 18.5 14.8 91.7 357 1,405 SDP0202 SDP02025 20 3600 254T 22.8 18.2 91.0 247 1,103 SDP0204 SDP02045 20 1800 256T 23.3 18.6 93.0 287 1,171 SDP0206 SDP02065 20 1200 286T 24.3 19.4 92.4 397 1,748 SDP0252 SDP02525 25 3600 256T 27.7 22.2 91.7 287 1,302 SDP0254 SDP02545 25 1800 284T 28.7 23.0 93.6 357 1,405 SDP0256 SDP02565 25 1200 324T 30.3 24.3 93.0 520 2,205 SDP0302 SDP03025 30 3600 284TS 33.6 26.9 92.4 370 1,650 SDP0304 SDP03045 30 1800 286T 34.3 27.4 94.1 397 1,656 SDP0306 SDP03065 30 1200 326T 35.9 28.8 93.6 595 2,468 SDP0402 SDP04025 40 3600 286TS 44.3 35.4 92.4 412 2,018 SDP0404 SDP04045 40 1800 324T 46.3 37.0 94.1 520 2,097 SDP0406 SDP04065 40 1200 364T 45.7 36.6 94.1 699 3,032 SDP0502 SDP05025 50 3600 324TS 58.5 46.8 93.0 518 2,534 SDP0504 SDP05045 50 1800 326T 58.3 46.6 94.5 595 2,367 SDP0506 SDP05065 50 1200 365T 57.8 46.3 94.1 772 3,532 SDP0602 SDP06025 60 3600 326TS 69.0 55.2 93.6 578 2,822 SDP0604 SDP06045 60 1800 364T 69.6 55.7 95.0 699 3,032 SDP0606 SDP06065 60 1200 404T 69.5 55.6 94.5 948 4,318 SDP0752 SDP07525 75 3600 364TS 82.5 66.0 94.1 666 3,614 SDP0754 SDP07545 75 1800 365T 86.0 68.8 95.0 772 3,609 SDP0756 SDP07565 75 1200 405T 86.0 68.8 94.5 1058 5,184

NOTE: (1) Prices subject to change without notice. (2) Ratings over 125HP are single voltage rated only (460V).

Motor Products - OPTIM® ODP A - 27 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES NEMA PREMIUM EFFICIENCY OPEN DRIP PROOF

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 230V/460V 575V 460V 575V EFF. WT. LBS PRICE SDP1002 SDP10025 100 3600 365TS 110 88.0 94.1 730 4,767 SDP1004 SDP10045 100 1800 404T 115 91.8 95.4 948 4,566 SDP1006 SDP10065 100 1200 444T 120 96.0 95.0 1170 8,911 SDP1252 SDP12525 125 3600 404TS 137 110 94.1 902 7,058 SDP1254 SDP12545 125 1800 405T 145 116 95.4 1058 6,134 SDP1256 SDP12565 125 1200 445T 150 120 95.0 1280 10,703 SDP1502 SDP15025 150 3600 405TS 164 131 94.5 981 8,409 SDP1504 SDP15045 150 1800 444T 170 136 95.8 1320 9,102 SDP1506 SDP15065 150 1200 445T 178 142 95.4 1370 11,512 SDP2002 SDP20025 200 3600 444TS 223 178 95.0 1150 10,945 SDP2004 SDP20045 200 1800 445T 226 181 95.8 1430 10,993 SDP2006 SDP20065 200 1200 447T 236 189 95.4 1810 14,205 SDP2502 SDP25025 250 3600 445TS 278 222 95.0 1280 12,949 SDP2504 SDP25045 250 1800 447T 281 225 95.8 1760 13,675 SDP2506 SDP25065 250 1200 449T 296 237 95.4 2160 18,015 SDP3002 SDP30025 300 3600 445TS 331 265 95.4 1320 16,666 SDP3004 SDP30045 300 1800 449T 335 268 95.8 1870 17,181 SDP3006 SDP30065 300 1200 449T 338 270 95.4 2615 21,834 SDP3502 SDP35025 350 3600 447TS 382 306 95.4 1590 18,846 SDP3504 SDP35045 350 1800 449T 391 313 95.8 2310 18,267 SDP3506 SDP35065 350 1200 5009B 404 323 95.4 3715 32,887 SDP4002 SDP40025 400 3600 449TS 434 347 95.8 1760 21,277 SDP4004 SDP40045 400 1800 449T 446 357 95.8 2445 22,125 SDP4006 SDP40065 400 1200 5009B 463 370 95.8 3835 36,911 SDP4502 SDP45025 450 3600 449TS 486 389 95.8 2125 23,069 SDP4504 SDP45045 450 1800 5009B 498 398 96.2 3620 32,040 SDP4506 SDP45065 450 1200 5009B 521 417 96.2 3960 38,119 SDP5002 SDP50025 500 3600 449TS 536 429 95.8 2225 24,332 SDP5004 SDP50045 500 1800 5009B 553 442 96.2 3790 34,329 SDP5006 SDP50065 500 1200 5009B 579 463 96.2 4075 39,200

NOTE: (1) Prices subject to change without notice. (2) Ratings over 125HP are single voltage rated only (460V). (3) RU logo for 449 Frames and Below.

Motor Products - OPTIM® ODP A - 28 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FEATURES

MODEL: GLOBAL XPE TYPE: AEHG_TK, AEJH_TK Effective 05-01-18 Supercedes All Previous

APPLICATIONS • Fans & Blowers • Compressors • Pumps

PRODUCT OVERVIEW • 150-2000HP • Totally Enclosed IP55 Design • 60Hz, 2300V/4000V • Horizontal F1 Mount • 3600, 1800, 1200 & 900 RPM • NEMA Premium Efficiency (250-500HP)

DESIGN FEATURES • 1.15 S.F. Sine Wave Power • Class F Insulation • 40˚C Ambient • Continuous Duty • NEMA Design B • Max Elevation 3300ft

MECHANICAL FEATURES • Anti-friction Bearings with Regreaseable Provisions • Insulated NDE Bearing on 3600RPM Motors, 600HP and Larger • Polyrex EM Grease • Copper/Copper Alloy Rotor • Cast-Iron Frame and End Brackets • Fabricated Steel Conduit Box and Fan Cover • Aluminum Fan • Number of Leads: 6 • Solderless Lug Terminals on All Leads • Grounding Terminal Inside Main Terminal Box and on Frame • Paint System: Phenolic Rust Proof Base with Polyurethane Top Coat • Stainless Steel Nameplate • 1045 Carbon Steel Shaft Material • Labyrinth Type Steel Flinger on Both Ends • Form Wound Windings With Complete VPI Treatment • Bi-Directional Rotation Except 3600RPM Motors CW View from NDE • Winding RTD's, Space Heaters and Provisions for Bearing RTD's

OTHER FEATURES • *CSA Certified for Class I, Division 2, Groups B, C & D (Class I, Zone 2, Groups IIB+H2, IIB & IIA) • Suitable for Across the Line or Reduced Voltage Starting • *Factory Certified for use on a VFD (Please Contact TWMI for Speed Ranges)

* Please contact your TWMI representative for availability of certified motors. ** Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.

Motor Products - GLOBAL XPE A - 29 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES PREMIUM EFFICIENCY TEFC SEVERE DUTY

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 2300V/4000V 4000V EFF. WT. LBS PRICE XPE1508 150 900 5007B 20.8 93.6 3600 29,950 XPE2006 200 1200 5007B 25.4 95.0 3550 28,883 XPE2008 200 900 5009B 27.5 94.1 4150 34,593 XPE2502 250 3600 5007A 30.8 95.0 3200 29,020 XPE2504 250 1800 5007B 30.3 95.0 3500 28,790 XPE2506 250 1200 5009B 31.7 95.0 4100 33,181 XPE2508 250 900 5009B 34.1 95.0 4300 41,244 XPE3002 300 3600 5009A 36.0 95.4 3500 35,174 XPE3004 300 1800 5009B 36.2 95.4 4000 32,205 XPE3006 300 1200 5009B 37.9 95.0 4350 38,962 XPE3008 300 900 5011B 40.6 95.0 4750 48,183 XPE3502 350 3600 5009A 42.0 95.4 3800 38,144 XPE3504 350 1800 5009B 42.2 95.4 4350 38,904 XPE3506 350 1200 5011B 44.2 95.0 4750 43,996 XPE3508 350 900 5808B 47.1 95.0 5100 55,341 XPE4002 400 3600 5011A 47.7 95.4 4800 41,813 XPE4004 400 1800 5011B 48.2 95.4 4450 42,505 XPE4006 400 1200 5011B 50.5 95.0 4500 47,969 XPE4008 400 900 5808B 53.8 95.0 5300 63,231 XPE4502 450 3600 5011A 53.7 95.4 5050 50,004 XPE4504 450 1800 5011B 54.0 954.0 4800 45,691 XPE4506 450 1200 5808B 56.4 95.4 5300 53,464 XPE4508 450 900 5810B 60.2 95.0 5900 67,998 XPE5002 500 3600 5808A 59.7 95.4 4700 54,446 XPE5004 500 1800 5808B 59.7 95.8 5000 50,539 XPE5006 500 1200 5810B 62.5 95.4 5300 59,706 XPE5008 500 900 6808B 63.8 95.4 7400 77,667 XPE6002 600 3600 5810A 71.3 95.8 5950 58,392 XPE6004 600 1800 5810B 71.9 95.8 5600 63,258 XPE6006 600 1200 5810B 74.9 95.4 5800 70,705 XPE6008 600 900 6808B 76.9 95.4 7900 87,533 XPE7002 700 3600 5810A 82.9 96.2 6600 60,775 XPE7004 700 1800 5810B 83.6 95.8 5750 71,438 XPE7006 700 1200 6808B 86.8 95.8 7550 79,012 XPE7008 700 900 6808B 88.5 95.4 8650 89,991 XPE8002 800 3600 6808A 94.0 96.2 8350 84,438 XPE8004 800 1800 6808B 95.5 95.8 7700 77,058 XPE8006 800 1200 6808B 99.1 95.8 8400 83,226 XPE8008 800 900 6810B 101 95.8 11000 93,384

NOTE: (1) Prices subject to change without notice. (2) For other voltages please contact a TWMI representative. (3) Contact TWMI for special design criteria, VFD duty & Hazloc Ratings.

Motor Products - GLOBAL XPE A - 30 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES PREMIUM EFFICIENCY TEFC SEVERE DUTY

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 2300V/4000V 4000V EFF. WT. LBS PRICE XPEF9002 900 3600 450C * * * 106,317 XPE9004 900 1800 6808B 108 95.8 8500 81,399 XPE9006 900 1200 6810B 112 95.8 10560 85,983 XPEF10002 1000 3600 450C * * * 122,943 XPEF12502 1250 3600 500C * * * 149,507 XPEF15002 1500 3600 560C * * * 174,992 * Please contact your local TWMI sales representative for more information.

NOTE: (1) Prices subject to change without notice. (2) For other voltages please contact a TWMI representative. (3) Contact TWMI for special design criteria, VFD duty & Hazloc Ratings.

Motor Products - GLOBAL XPE A - 31 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FEATURES

MODEL: GLOBAL TEFC TYPE: AFHG Effective 05-01-18 Supercedes All Previous

APPLICATIONS • Fans & Blowers • Compressors • Pumps

PRODUCT OVERVIEW • 150-2000HP • Totally Enclosed IP55 Design • 60Hz, 2300V/4000V • Horizontal F1 Mount • 3600, 1800, 1200 & 900 RPM • NEMA Premium Efficiency (250-500HP)

DESIGN FEATURES • 1.15 S.F. Sine Wave Power • Class F Insulation • 40˚C Ambient • Continuous Duty • NEMA Design B • Max Elevation 3300ft

MECHANICAL FEATURES • Anti-friction Bearings with Regreaseable Provisions • Insulated NDE Bearing • Polyrex EM Grease • Dynamically Balanced Copper/Copper Alloy Rotor Construction • Cast-Iron Frame, and End Brackets • Fabricated Steel Conduit Box • Fabricated Steel Fan Cover • Aluminum Fan 4, 6 & 8 Pole; Non-Sparking Plastic Fan 2 Pole • Number of Leads: 6 • Solderless Lug Terminals on All Leads • Grounding Terminal Inside Main Terminal Box and 2 Per Side on Frame • Paint System: Phenolic Rust Proof Base with Polyurethane Top Coat • Stainless Steel Nameplate • 1045 Carbon Steel Shaft Material • Labyrinth Type Steel Flinger on Both Ends • Form Wound Windings With Complete VPI Treatment • Bi-Directional Rotation Except 3600RPM Motors CCW View from NDE • Winding RTD's, Space Heaters and Provisions for Bearing RTD's • Vibration Probe Mounting Provisions

OTHER FEATURES • CSA Certified for Class I, Division 2, Groups B, C & D and Class I, Zone 2, Groups IIB+H2, IIB & IIA • CSA Certified for Class II, Division 2, Groups F & G • Suitable for Across the Line or Reduced Voltage Starting • *CSA Certified for use on a VFD Speed Range: VT10:1; CT 3:1

* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.

Motor Products - GLOBAL TEFC A - 32 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES PREMIUM EFFICIENCY TEFC SEVERE DUTY

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. WT. LIST HP RPM FRAME 2300V/4000V 4000V EFF. LBS PRICE GX1508 150 900 5007B 10.4 93.7 3520 29,950 GX2008 200 900 5009B 13.3 93.9 3850 34,593 GX2506 250 1200 5007B 15.9 95.0 3720 33,181 GX2508 250 900 5009B 16.4 94.1 4290 41,244 GX3006 300 1200 5009B 19.4 95.0 4205 38,962 GX3008 300 900 5011B 21.6 94.2 4755 48,183 GX3502 350 3600 5009A 12.2 95.0 3850 38,144 GX3504 350 1800 5009B 14.5 95.0 3740 38,904 GX3506 350 1200 5011B 21.2 95.0 4655 43,996 GX3508 350 900 5011B 22.0 94.4 5265 55,341 GX4002 400 3600 5011A 13.0 95.0 4370 41,813 GX4004 400 1800 5011B 17.1 95.0 4540 42,505 GX4006 400 1200 5011B 25.5 95.2 4910 47,969 GX4008 400 900 5808B 25.4 94.5 6930 63,231 GX4502 450 3600 5011A 13.5 95.0 4675 50,004 GX4504 450 1800 5011B 18.6 95.0 4840 45,691 GX4506 450 1200 5011B 27.1 95.3 5135 53,464 GX4508 450 900 5810B 31.5 94.6 7040 67,998 GX5002 500 3600 5011A 14.9 95.0 5070 54,446 GX5004 500 1800 5011B 16.3 95.0 4930 50,539 GX5006 500 1200 5810B 25.0 95.3 6580 59,706 GX5008 500 900 5810B 31.5 94.6 7370 77,667 GX6002 600 3600 5810A 22.1 95.2 6140 58,392 GX6004 600 1800 5011B 23.4 95.2 5025 63,258 GX6006 600 1200 5810B 29.9 95.3 7020 70,705 GX6008 600 900 5810B 46.5 94.6 7675 87,533 GX7002 700 3600 5810A 22.8 95.4 6535 60,775 GX7004 700 1800 5810B 31.2 95.4 6865 71,438 GX7006 700 1200 5810B 32.3 95.4 7305 79,012 GX7008 700 900 6808B 53.0 94.8 9225 89,991 GX8002 800 3600 5810A 31.5 95.6 6910 84,438 GX8004 800 1800 5810B 32.1 95.6 7000 77,058 GX8006 800 1200 6808B 38.4 95.4 9770 83,226 GX8008 800 900 6808B 59.5 95.0 10250 93,384 GX8002 800 3600 5810A 104.2 96.2 6910 84,438 GX8004 800 1800 5810B 107.8 95.8 7000 77,058 GX8006 800 1200 6808B 110.5 95.8 9770 83,226 GX8008 800 900 6808B 122.2 95.8 10250 93,384

NOTE: (1) Prices subject to change without notice. (2) For other voltages please contact a TWMI representative. (3) Contact TWMI for special design criteria, VFD duty & Hazloc Ratings.

Motor Products - GLOBAL TEFC A - 33 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES PREMIUM EFFICIENCY TEFC SEVERE DUTY

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. WT. LIST HP RPM FRAME 2300V/4000V 4000V EFF. LBS PRICE GX9004 900 1800 5810B 38.2 95.6 7260 81,399 GX9006 900 1200 6810B 42.1 95.5 10580 85,983 GX9008 900 900 6810B 66.6 95.2 11820 103,437 GX10004 1000 1800 6808B 57.2 95.6 9365 85,211 GX10006 1000 1200 6810B 41.9 95.7 11570 97,429 GX10008 1000 900 6810B 68.7 95.4 12405 112,356 GX12504 1250 1800 6810B 56.5 96.0 10810 95,771 GX12506 1250 1200 6811B 52.4 95.9 13005 114,557 GX12508 1250 900 6812B 83.7 95.6 14935 128,447 GX15004 1500 1800 6810B 69.8 96.1 12180 103,634 GX15006 1500 1200 6812B 58.0 96.1 14660 127,498 GX17504 1750 1800 6811B 88.1 96.3 13270 116,631 GX20004 2000 1800 6812B 87.5 96.5 14395 126,293

NOTE: (1) Prices subject to change without notice. (2) For other voltages please contact a TWMI representative. (3) Contact TWMI for special design criteria, VFD duty & Hazloc Ratings.

Motor Products - GLOBAL TEFC A - 34 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FEATURES

MODEL: GLOBAL ODP TYPE: AMGH Effective 05-01-18 Supercedes All Previous

APPLICATIONS • Fans & Blowers • Compressors • Pumps

PRODUCT OVERVIEW • 100-2000HP • WPI IPW23 ODP Design • 60Hz, 2300/4000V • Horizontal F1 Mount • 3600, 1800, 1200 & 900 RPM

DESIGN FEATURES • 1.15 S.F. • Class F Insulation • 40˚C Ambient • Continuous Duty • NEMA Design B • Max Elevation 3300ft

MECHANICAL FEATURES • Anti-friction Bearings with Regreaseable Provisions • Polyrex EM Grease • Copper/Copper Alloy Rotor Bar Except 447/449, 2 & 4; Which are Die-Cast Aluminum • Cast-Iron Frame and End Brackets • Fabricated Steel Conduit Box • Number of Leads: 6 • Solderless Lug Terminals on All Leads • Grounding Terminal Inside Main Terminal Box and on Frame • Paint System: Phenolic Rust Proof Base with Polyurethane Top Coat • Stainless Steel Nameplate • 1045 Carbon Steel Shaft Material • Steel Flinger on Both Ends • Form Wound Windings with Complete VPI Treatment • Bi-Directional Rotation Except 3600RPM Motors • Winding RTD’s, Space Heaters and Provisions for Bearing RTD’s • Vibration Probe Mounting Provisions

OTHER FEATURES • Suitable for Across the Line or Reduced Voltage Starting • CSA Certified • Factory Certified for VFD Duty (Please Contact TWMI for Details)

Motor Products - GLOBAL ODP A - 35 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES HIGH EFFICIENCY ODP SEVERE DUTY

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 2300V/4160V 4160V EFF. WT. LBS PRICE MDP1002 100 3600 447TS 13.2 92.0 1760 22,820 MDP1004 100 1800 447T 13.8 93.7 2050 25,075 MDP1006 100 1200 447T 15.0 94.6 1920 31,803 MDP1008 100 900 447T 15.5 93.2 2310 32,121 MDP1252 125 3600 447TS 16.1 93.1 1800 23,637 MDP1254 125 1800 447T 17.3 94.2 2100 25,284 MDP1256 125 1200 449T 18.4 94.7 2120 32,663 MDP1258 125 900 449T 19.0 93.3 2530 36,534 MDP1502 150 3600 447TS 19.0 93.1 1870 25,619 MDP1504 150 1800 449T 20.1 94.8 2360 26,069 MDP1506 150 1200 449T 21.9 94.8 2180 35,778 MDP1508 150 900 449T 23.0 93.4 3260 37,336 MDP2002 200 3600 449TS 25.3 93.7 1900 26,158 MDP2004 200 1800 449T 27.0 94.9 2380 26,697 MDP2006 200 1200 449T 30.5 94.9 2270 36,750 MDP2008 200 900 5009C 31.1 93.5 3550 41,043 MDP2502 250 3600 449TS 31.6 94.5 2020 28,473 MDP2504 250 1800 449T 33.9 95.0 2490 28,373 MDP2506 250 1200 449T 36.2 95.0 2340 39,246 MDP2508 250 900 5009C 38.0 93.6 3990 45,798 MDP3002 300 3600 449TS 38.0 94.5 2100 29,741 MDP3004 300 1800 449T 41.4 95.0 2550 31,203 MDP3006 300 1200 449T 43.7 95.0 2490 40,219 MDP3008 300 900 5011C 44.3 93.7 4380 48,318 MDP3502 350 3600 5009A 45.4 94.5 3580 38,542 MDP3504 350 1800 5009C 47.7 95.0 3330 36,894 MDP3506 350 1200 5009C 52.3 95.0 3770 41,682 MDP3508 350 900 5011C 52.3 93.8 4710 49,277 MDP4002 400 3600 5009A 51.2 94.5 3700 41,744 MDP4004 400 1800 5009C 54.6 95.0 3420 40,231 MDP4006 400 1200 5009C 59.2 95.1 3850 44,071 MDP4008 400 900 5012C 61.0 93.9 4820 53,612 MDP4502 450 3600 5009A 58.1 94.5 3800 42,319 MDP4504 450 1800 5009C 61.0 95.0 3520 41,228 MDP4506 450 1200 5011C 66.7 95.2 3720 47,688 MDP4508 450 900 5810C 65.6 94.0 6160 57,953 MDP5002 500 3600 5011A 64.4 94.5 3900 45,960 MDP5004 500 1800 5009C 67.3 95.0 3720 42,761 MDP5006 500 1200 5011C 73.0 95.3 3920 51,318 MDP5008 500 900 5810C 73.6 94.1 6450 62,007

NOTE: (1) Prices subject to change without notice. (2) For other voltages please contact a TWMI representative. (3) Not stocked in Canada. Please contact your TWMI representative for delivery.

Motor Products - GLOBAL ODP A - 36 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES HIGH EFFICIENCY ODP SEVERE DUTY

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 2300V/4160V 4160V EFF. WT. LBS PRICE MDP6002 600 3600 5011A 76.5 94.6 4000 48,971 MDP6004 600 1800 5011C 80.5 95.1 3770 47,817 MDP6006 600 1200 5011C 87.4 95.4 4250 52,744 MDP6008 600 900 5810C 88.0 94.2 6600 66,012 GDP7002 700 3600 5810A 83.5 94.5 5100 42,251 GDP7004 700 1800 5808B 85.1 94.5 5100 39,972 GDP7006 700 1200 5810B 88.5 94.5 6300 47,478 GDP7008 700 900 6808B 91.2 94.5 8400 60,489 MDP7002 700 3600 5011A 89.1 94.7 4200 51,018 MDP7004 700 1800 5011C 93.7 95.2 4100 48,266 MDP7006 700 1200 5012C 103 95.5 4650 57,330 MDP7008 700 900 5811C 103 94.3 6880 73,040 MDP8002 800 3600 5011A 102 94.8 4400 53,586 MDP8004 800 1800 5012C 106 95.3 4300 52,218 MDP8006 800 1200 5810C 111 95.6 5940 62,760 MDP8008 800 900 5811C 116 94.4 7100 80,990 MDP9002 900 3600 5012A 113 94.9 4600 57,963 MDP9004 900 1800 5012C 120 95.4 4400 55,078 MDP9006 900 1200 5810C 124 95.7 6230 69,343 MDP9008 900 900 5812C 131 94.5 7700 88,649 MDP10002 1000 3600 5012A 127 95.0 4730 61,734 MDP10004 1000 1800 5810C 130 95.5 6890 65,837 MDP10006 1000 1200 5811C 136 95.8 6980 74,528 MDP12502 1250 3600 5810A 158 95.1 5740 68,610 MDP12504 1250 1800 5811C 164 95.6 7070 73,473 MDP12506 1250 1200 5812B 171 95.9 7660 87,617 MDP15004 1500 1800 5812C 196 95.7 7790 79,799 MDP17504 1750 1800 5813C 230 95.8 8390 83,953 MDP20004 2000 1800 5813C 262 95.9 8400 91,214 * Please contact your local TWMI sales representative for more information.

NOTE: (1) Prices subject to change without notice. (2) For other voltages please contact a TWMI representative. (3) Not stocked in Canada. Please contact your TWMI representative for delivery.

Motor Products - GLOBAL ODP A - 37 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FEATURES

MODEL: FARM DUTY TYPE: BEGCFD, BECCFD, BECSFD Effective 05-01-18 Supercedes All Previous

APPLICATIONS • Fans & Blowers • Pumps • Compressors • Farm Equipment • Machine Tools

PRODUCT OVERVIEW • 1/3-10 HP • Totally Enclosed IP44 Design • 60Hz, 115/230V OR 230V; Single Phase • Horizontal F1 Mount • 1800RPM

DESIGN FEATURES • 1.15 S.F. • 40˚C Ambient • Continuous Duty • Max Elevation 3300ft • High Torque • Class B Insulation up to 3HP; Class F Insulation 3-10HP • Class B Temperature Rise • Capacitor Start, Induction Run .33-1.5HP; Capacitor Start, Capacitor Run 2-10HP

MECHANICAL FEATURES • Shielded Bearings • Multemp SRL Grease • Aluminum Rotor • Cast-Iron Frame and End Brackets 1.5-10HP, Rolled Steel for Others • Rolled Steel Fan Cover and Terminal Box • Plastic Fan • Grounding Terminal Inside Main Terminal Box • Paint System: Phenolic Rust Proof Base with Polyurethane Top Coat • Rubber Flinger on DE • Phenolic Alkyd Resin Varnish • Manual Reset Overload

OTHER FEATURES • CSA approved, UL Recognized

Motor Products - FARM DUTY A - 38 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES HIGH EFFICIENCY TEFC

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 115V/230V 230V EFF. WT. LBS PRICE FD0/34 0.33 1800 56 4.25 51.0 14.5 200 FD0/54 0.50 1800 56 4.7 58.0 16 210 FD0/74 0.75 1800 56 6.1 65.0 17 219 FD0014 1 1800 56 7.0 70.0 48 234 FD1/54 1.5 1800 145T 11.0 70.0 70 321 FD0024 2 1800 182T 14.0 73.0 92 442 FD0034 3 1800 182T 21.0 74.0 92 521 FD0054 5 1800 184T 30.0 78.5 103 595 FD7/54 7.5 1800 213T 36.0 80.0 178 986 FD0104 10 1800 215T 48.0 78.5 181 1,134

NOTE: (1) Prices subject to change without notice. (2) 115/230V: 1/3-2HP; 230V: 3-10HP.

Motor Products - FARM DUTY A - 39 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FEATURES

MODEL: OPTIM® JP TYPE: AEHH8N-JP Effective 05-01-18 Supercedes All Previous

APPLICATIONS • Pumps

PRODUCT OVERVIEW • 1-75HP • Totally Enclosed IP54 Design • 60Hz, 230V/460V, or 575V • Horizontal F1 Mount • 3600, 1800 & 1200 RPM • NEMA Premium Efficiency

DESIGN FEATURES • 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power • 40˚C Ambient • Continuous Duty • Max Elevation 3300ft • Class F Insulation • NEMA Design B or C

MECHANICAL FEATURES • Shielded Bearings Frames 140JP(2,4&6Pole)-280JP(4&6Pole) and Open Bearings with Regreaseable Provisions Frames 280JP(2Pole), 320JP • Polyrex EM Grease in all Regreaseable Bearings, Multemp SRL Grease in Shielded Bearings • Aluminum Rotor • Cast-Iron Frame and End Brackets • Cast-Iron Fan Cover and Terminal Box • Non-Sparking Plastic Fan • Number of Leads 230/460V: 9 Leads 1-5HP; 12 Leads 7.5 and Larger; 575V: 3 Leads • Solderless Lug Terminals on All Leads • Grounding Terminal Inside Main Terminal Box • Interchangeable F1 and F2 mounting • Paint System: Phenolic Rust Proof Base with Lacquer Top Coat • Stainless Steel Nameplate • Rubber Flinger on DE Frames 140JP(2,4&6Pole)-280JP(4&6Pole); Steel Flinger on Both Ends 280JP(2Pole), 320JP(2,4&6Pole) and Larger • Phenolic Alkyd Resin Varnish • *HPE™ High Pulse Endurance Spike Resistant Wire • JP Pump Shaft

OTHER FEATURES • CSA Certified for Class I, Division 2, Groups B, C & D (Class I, Zone 2, Groups IIB+H2, IIB and IIA) • *Speed Ranges up to 10:1 CT, and 20:1 VT. Refer to data sheet for rating specific turn down ratios • *Meets NEMA MG1 Part 31.4.4.2

* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.

Motor Products - OPTIM® JP A - 40 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES PREMIUM EFFICIENCY TEFC PUMP MOTOR

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 230V/460V 575V 460V 575V EFF. WT. LBS PRICE CJP0012 CJP00125 1 3600 143JP 1.34 1.07 82.5 46 381 CJP0014 CJP00145 1 1800 143JP 1.50 1.20 85.5 61 381 CJP0016 CJP00165 1 1200 145JP 1.73 1.38 82.5 68 473 CJP1/52 CJP1/525 1.5 3600 143JP 2.00 1.60 84.0 61 432 CJP1/54 CJP1/545 1.5 1800 145JP 2.08 1.66 86.5 68 431 CJP1/56 CJP1/565 1.5 1200 182JP 2.53 2.02 87.5 106 517 CJP0022 CJP00225 2 3600 145JP 2.52 2.02 86.5 68 465 CJP0024 CJP00245 2 1800 145JP 2.78 2.22 86.5 68 461 CJP0026 CJP00265 2 1200 184JP 3.00 2.40 88.5 126 583 CJP0032 CJP00325 3 3600 182JP 3.53 2.82 88.5 106 524 CJP0034 CJP00345 3 1800 182JP 3.74 2.99 89.5 106 520 CJP0036 CJP00365 3 1200 213JP 4.02 3.22 89.5 186 818 CJP0052 CJP00525 5 3600 184JP 5.72 4.58 88.5 126 623 CJP0054 CJP00545 5 1800 184JP 6.12 4.90 89.5 126 586 CJP0056 CJP00565 5 1200 215JP 6.24 4.99 91.0 213 1,008 CJP7/52 CJP7/525 7.5 3600 213JP 8.67 6.94 91.0 186 832 CJP7/54 CJP7/545 7.5 1800 213JP 8.85 7.08 91.7 186 850 CJP7/56 CJP7/565 7.5 1200 254JP 9.59 7.67 91.0 325 1,415 CJP0102 CJP01025 10 3600 215JP 11.5 9.20 91.0 213 997 CJP0104 CJP01045 10 1800 215JP 11.6 9.28 91.7 213 1,034 CJP0106 CJP01065 10 1200 256JP 12.8 10.2 91.0 354 1,734 CJP0152 CJP01525 15 3600 254JP 16.6 13.3 92.4 325 1,364 CJP0154 CJP01545 15 1800 254JP 17.3 13.8 92.4 325 1,338 CJP0156 CJP01565 15 1200 284JP 18.2 14.6 92.4 464 2,258 CJP0202 CJP02025 20 3600 256JP 21.9 17.5 92.4 354 1,745 CJP0204 CJP02045 20 1800 256JP 23.0 18.4 93.0 354 1,737 CJP0206 CJP02065 20 1200 286JP 24.3 19.4 91.7 507 2,826 CJP0252 CJP02525 25 3600 284JP 27.8 22.2 92.4 464 2,199 CJP0254 CJP02545 25 1800 284JP 29.1 23.3 93.6 464 2,174 CJP0256 CJP02565 25 1200 324JP 30.3 24.2 93.0 694 3,380 CJP0302 CJP03025 30 3600 286JP 33.2 26.6 93.0 507 2,559 CJP0304 CJP03045 30 1800 286JP 34.3 27.4 93.6 507 2,559 CJP0306 CJP03065 30 1200 326JP 37.5 30.0 93.0 784 4,113 CJP0402 CJP04025 40 3600 324JP 44.2 35.4 94.1 694 3,317 CJP0404 CJP04045 40 1800 324JP 46.3 37.0 94.1 694 3,295 CJP0406 CJP04065 40 1200 364JP 46.0 36.8 94.1 926 5,282 CJP0502 CJP05025 50 3600 326JP 54.7 43.8 94.1 784 4,215 CJP0504 CJP05045 50 1800 326JP 56.9 45.5 94.5 784 4,157 CJP0506 CJP05065 50 1200 365JP 57.8 46.2 94.1 954 6,525 CJP0602 CJP06025 60 3600 364JP 64.2 51.4 94.1 926 5,432 CJP0604 CJP06045 60 1800 364JP 68.4 54.7 95.0 926 5,212 CJP0752 CJP07525 75 3600 365JP 79.9 63.9 94.5 954 6,807 CJP0754 CJP07545 75 1800 365JP 85.1 68.1 95.4 954 6,612

NOTE: (1) Prices subject to change without notice. (2) Not stocked in Canada. Please contact your TWMI representative for delivery. (3) For VFD applcations please refer to page D-18.

Motor Products - OPTIM® JP A - 41 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FEATURES

MODEL: OPTIM® JM TYPE: AEHH8N-JM Effective 05-01-18 Supercedes All Previous

APPLICATIONS • Pumps

PRODUCT OVERVIEW • 1-50HP • Totally Enclosed IP54 Design • 60Hz, 230V/460V, or 575V • Horizontal F1 Mount • 3600, 1800 & 1200 RPM • NEMA Premium Efficiency

DESIGN FEATURES • 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power • 40˚C Ambient • Continuous Duty • Max Elevation 3300ft • Class F Insulation • NEMA Design B or C

MECHANICAL FEATURES • Shielded Bearings Frames 140JM(2,4&6Pole)-280JM(4&6Pole) and Open Bearings with Regreaseable Provisions Frames 280JM(2Pole), 320JM • Polyrex EM Grease in all Regreaseable Bearings, Multemp SRL Grease in Shielded Bearings • Aluminum Rotor • Cast-Iron Frame and End Brackets • Cast-Iron Fan Cover and Terminal Box • Non-Sparking Plastic Fan • Number of Leads 230/460V: 9 Leads 1-5HP; 12 Leads 7.5 and Larger; 575V: 3 Leads • Solderless Lug Terminals on All Leads • Grounding Terminal Inside Main Terminal Box • Interchangeable F1 and F2 mounting • Paint System: Phenolic Rust Proof Base with Lacquer Top Coat • Stainless Steel Nameplate • Rubber Flinger on DE Frames 140JM(2,4&6Pole)-280JM(4&6Pole); Steel Flinger on Both Ends 280JM(2Pole), 320JM • Phenolic Alkyd Resin Varnish • *HPE™ High Pulse Endurance Spike Resistant Wire • JM Pump Shaft

OTHER FEATURES • CSA Certified for Class I, Division 2, Groups B, C & D (Class I, Zone 2, Groups IIB+H2, IIB and IIA) • *Speed Ranges up to 10:1 CT, and 20:1 VT. Refer to data sheet for rating specific turn down ratios • *Meets NEMA MG1 Part 31.4.4.2

* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.

Motor Products - OPTIM® JM A - 42 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES PREMIUM EFFICIENCY TEFC PUMP MOTOR

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS F/L APPROX. LIST HP RPM FRAME 230V/460V 575V 460V 575V EFF. WT. LBS PRICE CJM0012 CJM00125 1 3600 143JM 1.34 1.07 82.5 61 381 CJM0014 CJM00145 1 1800 143JM 1.50 1.20 85.5 61 381 CJM0016 CJM00165 1 1200 145JM 1.73 1.38 82.5 68 473 CJM1/52 CJM1/525 1.5 3600 143JM 2.00 1.60 84.0 61 432 CJM1/54 CJM1/545 1.5 1800 145JM 2.08 1.66 86.5 68 431 CJM1/56 CJM1/565 1.5 1200 182JM 2.53 2.02 87.5 106 517 CJM0022 CJM00225 2 3600 145JM 2.52 2.02 86.5 68 465 CJM0024 CJM00245 2 1800 145JM 2.78 2.22 86.5 68 461 CJM0026 CJM00265 2 1200 184JM 3.00 2.40 88.5 126 583 CJM0032 CJM00325 3 3600 182JM 3.53 2.82 88.5 106 524 CJM0034 CJM00345 3 1800 182JM 3.74 2.99 89.5 106 520 CJM0036 CJM00365 3 1200 213JM 4.02 3.22 89.5 186 818 CJM0052 CJM00525 5 3600 184JM 5.72 4.58 88.5 126 623 CJM0054 CJM00545 5 1800 184JM 6.12 4.90 89.5 126 586 CJM0056 CJM00565 5 1200 215JM 6.24 4.99 91.0 213 1,008 CJM7/52 CJM7/525 7.5 3600 213JM 8.67 6.94 91.0 186 832 CJM7/54 CJM7/545 7.5 1800 213JM 8.85 7.08 91.7 186 850 CJM7/56 CJM7/565 7.5 1200 254JM 9.59 7.67 91.0 325 1,415 CJM0102 CJM01025 10 3600 215JM 11.50 9.20 91.0 213 997 CJM0104 CJM01045 10 1800 215JM 11.60 9.28 91.7 213 1,034 CJM0106 CJM01065 10 1200 256JM 12.80 10.24 91.0 354 1,734 CJM0152 CJM01525 15 3600 254JM 16.60 13.28 92.4 325 1,364 CJM0154 CJM01545 15 1800 254JM 17.30 13.84 92.4 325 1,338 CJM0156 CJM01565 15 1200 284JM 18.20 14.56 92.4 464 2,258 CJM0202 CJM02025 20 3600 256JM 21.90 17.52 92.4 354 1,745 CJM0204 CJM02045 20 1800 256JM 23.00 18.40 93.0 354 1,737 CJM0206 CJM02065 20 1200 286JM 24.30 19.44 91.7 507 2,826 CJM0252 CJM02525 25 3600 284JM 27.80 22.24 92.4 464 2,199 CJM0254 CJM02545 25 1800 284JM 29.10 23.28 93.6 464 2,174 CJM0256 CJM02565 25 1200 324JM 30.30 24.24 93.0 694 3,380 CJM0302 CJM03025 30 3600 286JM 33.20 26.56 93.0 507 2,559 CJM0304 CJM03045 30 1800 286JM 34.30 27.44 93.6 507 2,559 CJM0306 CJM03065 30 1200 326JM 37.50 30.00 93.0 784 4,113 CJM0402 CJM04025 40 3600 324JM 44.20 35.36 94.1 694 3,317 CJM0404 CJM04045 40 1800 324JM 46.30 37.04 94.1 694 3,295 CJM0502 CJM05025 50 3600 326JM 54.70 43.76 94.1 784 4,215 CJM0504 CJM05045 50 1800 326JM 56.90 45.52 94.5 784 4,157

NOTE: (1) Prices subject to change without notice. (2) For VFD applcations please refer to page D-18.

Motor Products - OPTIM® JM A - 43 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FEATURES

MODEL: OPTIM® VH VERTICAL HOLLOW SHAFT WPI TYPE: AMRCNH Effective 05-01-18 Supercedes All Previous

APPLICATIONS • Pumps • Irrigation

PRODUCT OVERVIEW • 3-400HP • 3600*, 1800 & 1200 RPM (*Up to 150 HP) • WPI Enclosure / IP22 Design • 60Hz, 230V/460V, 460V or 575V • High Thrust Vertical Hollow Shaft with P-Base • NEMA Premium Efficiency

DESIGN FEATURES • 1.15 S.F. Sine Wave Power; 1.0 S.F. VFD Power • Class F Insulation • Class B Temperature Rise • Max Elevation 3300ft • Continuous Duty • NEMA Design B • 40˚C Ambient

MECHANICAL FEATURES • Guide Bearings: Shielded Bearings Frames 210TP-280TP and Open Bearings with Regreaseable Provisions Frames 320TP and Larger • Thrust Bearings: Re-Greasable Angular Contact 210TP-280TP and Oil Lubricated Angular Contact with Site Glass 320TP and Larger • Polyrex EM Grease in all Regreaseable Bearings, Multemp SRL Grease in Shielded Bearings • Thrust Bearing Oil Requirements: Turbine Oil With a Viscosity of 150 S.S.U. at 100°F for 2P, 300 S.S.U. at 100°F for 4P & 6P Frames 320TP-400TP; 300 S.S.U. at 100°F for 440TP and Larger • Aluminum Rotor • Cast Iron Frame, End Brackets, and Main Conduit Box • Fabricated Steel Drip Cover • 1045 Carbon Steel Hollow Shaft • Number of Leads 230/460V: 9 Leads 3-5HP; 12 Leads 7.5-125HP; 6 Leads 150HP and Larger • Number of Leads 575V: 6 Leads • Solderless Lug Terminals on All Leads • Grounding Terminal Inside Main Terminal Box • Paint System: Phenolic Rust Proof Base with Lacquer Top Coat • Stainless Steel Nameplate and Rodent Screens • Metal Flinger at Flange Bracket End 320TP and Larger • Phenolic Alkyd Resin Varnish and Spray Enamel Coat • *HPE™ High Pulse Endurance Spike Resistant Wire • Coupling and Gib Key Included (BX Dimension Required at Time of Order) • Standard Non-Reverse Ratchet with Heavy Duty Stainless Steel Balls • Space Heater Terminated in Main Terminal Box • CCW Rotation when Viewed from Top • Optional Steady Bushing

OTHER FEATURES • CSA Certified & UL listed • *Meets NEMA MG1 Part 31.4.4.2 • *Inverter Duty Speed Range: 450 RPM to Rated RPM, S.F.=1.0 • UL Listed (UL 1004-5) for Fire Pump Applications

* Precautions should be taken to eliminate or reduce voltage spikes and shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.

Motor Products - OPTIM® VH A - 44 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES PREMIUM EFFICIENCY WPI PUMP MOTOR HIGH THRUST VERTICAL HOLLOW SHAFT

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS DOWN F/L APPROX. LIST HP RPM FRAME THRUST EFF. WT. LBS PRICE 230V/460V 575V 230/460V 575V LBS VCN0036 VCN00365 3 1200 213TP 4.6 3.7 88.5 2950 197 2,496 VCN0056 VCN00565 5 1200 215TP 7.2 5.7 89.5 2950 209 2,617 VCN7/54 VCN7/545 7.5 1800 213TP 9.5 7.6 91.0 2600 197 2,462 VCN7/56 VCN7/565 7.5 1200 254TP 10.1 8.1 90.2 3850 303 3,255 VCN0102 VCN01025 10 3600 213TP 12.2 9.8 89.5 2000 197 2,487 VCN0104 VCN01045 10 1800 215TP 12.2 9.7 91.7 2600 209 2,605 VCN0106 VCN01065 10 1200 256TP 12.8 10.3 91.7 3850 324 3,434 VCN0152 VCN01525 15 3600 215TP 17.9 14.3 90.2 2000 209 2,645 VCN0154 VCN01545 15 1800 254TP 18.2 14.6 93.0 3350 303 3,106 VCN0156 VCN01565 15 1200 284TP 19.1 15.3 91.7 3850 417 3,979 VCN0202 VCN02025 20 3600 254TP 22.9 18.3 91.0 2700 303 3,025 VCN0204 VCN02045 20 1800 256TP 24.3 19.4 93.0 3350 324 3,347 VCN0206 VCN02065 20 1200 286TP 24.9 19.9 92.4 3850 456 4,349 VCN0252 VCN02525 25 3600 256TP 28.1 22.4 91.7 2700 324 3,289 VCN0254 VCN02545 25 1800 284TP 29.4 23.5 93.6 3350 417 4,167 VCN0256 VCN02565 25 1200 324TP 30.3 24.3 93.0 6000 622 6,697 VCN0302 VCN03025 30 3600 284TP 34.0 27.2 91.7 2700 417 3,955 VCN0304 VCN03045 30 1800 286TP 34.7 27.8 94.1 3350 456 4,365 VCN0306 VCN03065 30 1200 326TP 35.9 28.8 93.6 6000 675 7,116 VCN0402 VCN04025 40 3600 286TP 44.8 35.8 92.4 2700 456 4,162 VCN0404 VCN04045 40 1800 324TP 46.3 37.0 94.1 5700 622 6,335 VCN0406 VCN04065 40 1200 364TP 45.7 36.6 94.1 6600 775 8,537 VCN0502 VCN05025 50 3600 324TP 55.9 44.7 93.0 4600 622 6,576 VCN0504 VCN05045 50 1800 326TP 58.3 46.6 94.5 5700 675 6,658 VCN0506 VCN05065 50 1200 365TP 57.8 46.3 94.1 6600 860 9,087 VCN0602 VCN06025 60 3600 326TP 66.7 53.4 93.6 4600 675 6,826 VCN0604 VCN06045 60 1800 364TP 69.6 55.7 95.0 6000 775 8,069 VCN0606 VCN06065 60 1200 404TP 69.5 55.6 94.5 9000 1111 12,299 VCN0752 VCN07525 75 3600 364TP 82.9 66.3 93.6 5000 775 7,886 VCN0754 VCN07545 75 1800 365TP 86.0 68.8 95.0 6000 860 8,352 VCN0756 VCN07565 75 1200 405TP 85.9 68.7 94.5 9000 1215 12,887 VCN1002 VCN10025 100 3600 365TP 111 88.4 93.6 5000 860 8,344 VCN1004 VCN10045 100 1800 404TP 115 92.0 95.4 7900 1111 11,833 VCN1006 VCN10065 100 1200 444TP 120 96.0 95.0 12000 1800 14,577 VCN1252 VCN12525 125 3600 404TP 138 110 94.1 5000 1073 11,759 VCN1254 VCN12545 125 1800 405TP 145 116 95.4 7900 1215 12,283 VCN1256 VCN12565 125 1200 445TP 150 120 95.0 11900 1840 15,022 * Please contact your local TWMI sales representative for more information.

NOTE: (1) Prices subject to change without notice. (2) Ratings over 125HP are single voltage rated only (460V). (3) Please specify coupling diameter (BX dimension) at time of order (see page B-9). (4) For available accessories please refer to pages B-9 through B-11. (5) For VFD applcations please refer to page D-18.

Motor Products - OPTIM® VH A - 45 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES PREMIUM EFFICIENCY WPI PUMP MOTOR HIGH THRUST VERTICAL HOLLOW SHAFT

Effective 05-01-18 Supercedes All Previous

CATALOGUE NUMBER F.L. AMPS DOWN F/L APPROX. LIST HP RPM FRAME THRUST EFF. WT. LBS PRICE 230V/460V 575V 460V 575V LBS VCN1502 VCN15025 150 3600 405TP 165 132 94.1 5000 1135 12,045 VCN1504 VCN15045 150 1800 444TP 170 136 95.8 10700 1830 16,716 VCN1506 VCN15065 150 1200 445TP 178 142 95.4 11800 1970 15,909 VCN2004 VCN20045 200 1800 445TP 225 180 95.8 10700 1980 17,150 VCN2006 VCN20065 200 1200 447TP 236 189 95.4 14900 2660 23,579 VCN2504 VCN25045 250 1800 445TP20 283 226 95.8 13400 2440 21,847 VCN2506 VCN25065 250 1200 449TP 295 236 95.4 14700 2980 25,608 VCN3004 VCN30045 300 1800 447TP 335 268 95.8 13400 2670 23,140 VCN3006 VCN30065 300 1200 449TP 371 297 95.8 - 3260 27,978 VCN3504 VCN35045 350 1800 447TP 388 310 95.8 13300 2800 23,927 VCN4004 VCN40045 400 1800 449TP 442 354 95.8 13200 3070 26,784 * Please contact your local TWMI sales representative for more information.

NOTE: (1) Prices subject to change without notice. (2) Ratings over 125HP are single voltage rated only (460V). (3) Please specify coupling diameter (BX dimension) at time of order (see page B-9). (4) For available accessories please refer to pages B-9 through B-11. (5) For VFD applcations please refer to page D-18. (6) 8P design also available with longer delivery. (7) 450-800HP also available with longer delivery.

Motor Products - OPTIM® VH A - 46 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 PARTS & ACCESSORIES Effective 05-01-18 Supercedes All Previous

C-FLANGE KITS

TEFC - CAST-IRON OPTIM® TEFC / GLOBAL XPE ADVANTAGE PLUS IEEE READY ADVANTAGE PLUS IEEE 841 FRAME CATALOGUE NUMBER LIST PRICE CATALOGUE NUMBER LIST PRICE CATALOGUE NUMBER LIST PRICE 56 ------140T CFE140T 87 CFHH140T 87 CFHB140T 87 180T CFE180T 102 CFHH180T 102 CFHB180T 102 210T CFE210T 145 CFHH210T 145 CFHB210T 145 250T CFE250T 189 CFHH250T 189 CFHB250T 189 280TS CFE280TS 319 CFHH280 319 CFHB280 319 280T CFE280T 319 CFHH280 319 CFHB280 319 320TS CFE320 377 CFHH320 377 CFHB320 377 320T CFE320 377 CFHH320 377 CFHB320 377 360TS CFE360TS 406 CFHH360TS 406 CFHB360TS 406 360T CFE360T 406 CFHH360T 406 CFHB360T 406 400TS CFE400TS 479 CFHH400TS 479 CFHB400TS 479 400T CFE400T 479 CFHH400T 479 CFHB400T 479 444TS CFE440TS 1,277 CFHH440TS 1,277 CFHB440TS 1,277 444T CFE444/5T 1,277 CFHH444/5T 1,277 CFHB444/5T 1,277 445TS CFE440TS 1,277 CFHH440TS 1,277 CFHB440TS 1,277 445T CFE444/5T 1,277 CFHH444/5T 1,277 CFHB444/5T 1,277 447TS CFE440TS 1,277 CFHH440TS 1,277 CFHB440TS 1,277 447T CFE447/9T 1,277 CFHH447/9T 1,277 CFHB447/9T 1,277 449TS CFE440TS 1,277 CFHH440TS 1,277 CFHB440TS 1,277 449T CFE447/9T 1,277 CFHH447/9T 1,277 CFHB447/9T 1,277 5007A CFE1698 1,698 - - - - 5007B/C CFE1698 1,698 - - - - 5009A CFE1698 1,698 CFHH5009A 1,698 CFHB5009A 1,698 5009B/C CFE1698 1,698 CFHH5009B/C 1,698 CFHB5009B/C 1,698 5011A CFE1698 1,698 CFHH5011A 1,698 CFHB5011A 1,698 5011B/C CFE1698 1,698 CFHH5011B/C 1,698 CFHB5011B/C 1,698 5806B/C CFE2758 2,758 - - - - 5808A CFE2758 2,758 - - - - 5808B/C CFE2758 2,758 CFHH5808B/C 2,758 CFHB5808B/C 2,758 5810A CFE2758 2,758 - - - - 5810B/C CFE2758 2,758 CFHH5810B/C 2,758 CFHB5810B/C 2,758 6808A CFE3048 3,048 - - - - 6808B/C CFE3048 3,048 - - - - 6810B/C CFE3048 3,048 - - - -

NOTE: (1) Prices subject to change without notice.

Parts & Accessories B - 1 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 PARTS & ACCESSORIES Effective 05-01-18 Supercedes All Previous

C-FLANGE KITS

ODP - CAST-IRON OPTIM® ODP FRAME CATALOGUE NUMBER LIST PRICE 56 - 140T - 180T - 210T - 250T CFDH250T 189 280TS CFDH280TS 319 280T CFDH280T 319 320TS CFDH320 377 320T CFDH320 377 360TS CFDH360TS 406 360T CFDH360T 406 400TS CFDH400TS 479 400T CFDH400T 479 444TS CFDH444/5TS 1,277 444T CFDH444/5T 1,277 445TS CFDH444/5TS 1,277 445T CFDH444/5T 1,277 447TS CFDH447/9TS 1,277 447T CFDH447/9T 1277 449TS CFDH447/9TS 1,277 449T CFDH447/9T 1,277 5009B/C CFDH5009B/C 1,698

NOTE: (1) Prices subject to change without notice.

TEFC - ROLLED STEEL ROLLED STEEL TEFC FARM DUTY FRAME CATALOGUE NUMBER LIST PRICE CATALOGUE NUMBER LIST PRICE *56 CFG56 75 CFS56 77 **56/140T CFG5614 77 CFS140T 87 180T CFGP180T 102 CFS180T 102 210T CFGP210T 145 CFS210T 145 * Fits motors with P Dimension of 6.40”. ** Fits motors with P Dimension of 5.69”.

NOTE: (1) Prices subject to change without notice.

Parts & Accessories B - 2 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 PARTS & ACCESSORIES Effective 05-01-18 Supercedes All Previous

C-FLANGE KITS

ODP - ROLLED STEEL ROLLED STEEL ODP FRAME CATALOGUE NUMBER LIST PRICE *56 CFDT56 75 **56/140T CFDT5614 77 180T CFDT180T 102 210T CFDT210T 145 250T CFDT250T 189 280TS CFDT280 319 280T CFDT280 319 * Fits motors with P Dimension of 6.42”. ** Fits motors with P Dimension of 7.24”.

NOTE: (1) Prices subject to change without notice.

TEXP OPTIM® TEXP FRAME CATALOGUE NUMBER LIST PRICE 140T CFXP140T 100 180T CFXP180T 133 210T CFXP210T 167 250T CFXP250T 217 280TS CFXP280TS 367 280T CFXP280T 367 320TS CFXP320 434 320T CFXP320 434 360TS CFXP360TS 467 360T CFXP360T 467 400TS CFXP400TS 917 400T CFXP400T 917 444TS CFXP440TS 1,469 444T CFXP444/5T 1,469 445TS CFXP440TS 1,469 445T CFXP444/5T 1,469

NOTE: (1) Prices subject to change without notice. (2) Must be installed by a hazardous locations CSA-Qualified Repair Facility.

Parts & Accessories B - 3 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 PARTS & ACCESSORIES Effective 05-01-18 Supercedes All Previous

BLOWER KITS

FRAME CATALOGUE NUMBER LIST PRICE 140T BLK140T 221 180T BLK180T 315 210T BLK210T 378 250T BLK250T 551 280T BLK280T 599 280TS BLK280TS 599 320T BLK320T 1,166 360T BLK360T 1,370 400T BLK400T 1,418

NOTE: (1) Prices subject to change without notice.

Parts & Accessories B - 4 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 PARTS & ACCESSORIES Effective 05-01-18 Supercedes All Previous

SLIDE BASES

FRAME CATALOGUE NUMBER LIST PRICE FRAME CATALOGUE NUMBER LIST PRICE 56 SBS56 25 326T SB326T 138 143T SB143T 48 364T SB364T 175 145T SB145T 48 365T SB365T 175 182T SB182T 52 404T SB404T 257 184T SB184T 52 405T SB405T 257 213T SB213T 66 444T SB444T 320 215T SB215T 66 445T SB445T 320 254T SB254T 94 447T SB447T 438 256T SB256T 94 449T SB449T 451 284T SB284T 103 5007 SB5007 609 286T SB286T 103 5009 SB5009 609 324T SB324T 138 - - -

NOTE: (1) Prices subject to change without notice.

Parts & Accessories B - 5 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 PARTS & ACCESSORIES Effective 05-01-18 Supercedes All Previous

LABYRINTH SEALS

SELECTION GUIDE INPRO/SEAL (VBXX) INPRO/SEAL (MGS) ADVANTAGE PLUS 841 OPTIM HE PLUS / GLOBAL BRG CATALOGUE LIST CATALOGUE LIST DE NDE DE NDE NUMBER PRICE NUMBER PRICE 6205/6305 IS05 59 IS05MGS 295 140T 140T 140T 140T 6206/6306 IS06 92 IS06MGS 348 180T 180T/210T 180T 180T/210T 6207/6307 IS07 98 IS07MGS 406 - 250T - 250T 6208/6308 IS08 107 IS08MGS 465 210T - 210T - 6209/6309 IS09 112 IS09MGS 523 250T - 250T - 6210/6310 IS10 120 IS10MGS 580 - 280T/280TS - 280T 6211/6311 IS11 126 IS11MGS 639 280T/280TS - 280T/280TS 280TS 6212/6312 IS12 140 IS12MGS 697 320T/320TS/360TS 320T/320TS/360TS 320T/320TS/360TS 320T/320TS/360TS 6213/6313 IS13 153 IS13MGS 754 360T/400TS 360T/400T/400TS 360T/400TS 360T/400T/400TS 6214/6314 IS14 471 IS14MGS 777 - - 444/5TS/447/9TS 444/5TS/447/9TS 6314 IS14B 471 IS14MGSB 777 444/5TS/447/9T 444/5TS/447/9T - - 6215/6315 IS15 507 IS15MGS 1,013 - - 5000A 5000A 6315 IS15B 507 IS15MGSB 1,013 5000A 5000A - - 6216/6316 IS16 536 IS16MGS 1,073 - 444/5T/447/9T - 444/5T/447/9T 6217/6317 IS17 598 IS17MGS 1,196 400T - 400T - 6218/6318 IS18 611 IS18MGS 1,225 - - 444/5T - 6318 IS18B 611 IS18MGSB 1,225 444/5T - - - 6220/6320 IS20 681 IS20MGS 1,364 - - 447/9T 5000BC 6320 IS20B 681 IS20MGSB 1,364 447/9T 5000BC - - 6222/6322 IS22 754 IS22MGS 1,507 - - - 5800BC 6224/6324 IS24 822 IS24MGS 1,676 - - 5000BC - 6322/6324 IS22/24B 754 IS22/24MGSB 1,507 5000BC 5800BC/6800BC - - 6226/6326 IS26 894 IS26MGS 1,788 - - 5800BC/6800BC - 6326 IS26B 894 IS26MGSB 1,788 5800BC/6800BC - - -

NOTE: (1) Prices subject to change without notice. (2) Inpro/Seals are also available in 303 Stainless Steel, Caplock & Vertical Shaft Up designs.

Parts & Accessories B - 6 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 PARTS & ACCESSORIES Effective 05-01-18 Supercedes All Previous

SHAFT GROUNDING RINGS

AEGIS (SGR) BRG CATALOGUE NUMBER LIST PRICE 56 SGR56 139 140T SGR140 148 180T SGR180 155 210T SGR210 170 250T, 280TS SGR2528 201 280T, 320TS, 360TS SGR2836 264 320T, 400TS SGR3240 295 360T, 440TS SGR3644 326 5000A, 5800A, 6800A SGR5068A 382 400T SGR400 435 440T SGR440 607 5000BC SGR5000 877 5800BC, 6800BC SGR5868 1,169

NOTE: (1) Prices subject to change without notice.

Parts & Accessories B - 7 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 PARTS & ACCESSORIES Effective 05-01-18 Supercedes All Previous

COUPLINGS (FOR OPTIM® VH VERTICAL HOLLOWSHAFT MOTORS)

CATALOGUE CATALOGUE FRAME BX DIMENSION LIST PRICE FRAME BX DIMENSION LIST PRICE NUMBER NUMBER 210TP CP210-0.751 0.751 205 444/5TP CP444/5-1.188 1.188 1,703 210TP CP210-0.876 0.876 205 444/5TP CP444/5-1.251 1.251 1,703 210TP CP210-0.938 0.938 205 444/5TP CP444/5-1.438 1.438 1,703 210TP CP210-1.001 1.001 205 444/5TP CP444/5-1.501 1.501 1,703 250/280TP CP2528-0.751 0.751 236 444/5TP CP444/5-1.688 1.688 1,703 250/280TP CP2528-0.876 0.876 236 444/5TP CP444/5-1.751 1.751 1,703 250/280TP CP2528-1.001 1.001 236 444/5TP CP444/5-1.938 1.938 1,703 250/280TP CP2528-1.188 1.188 236 445TP20 / 447/9TP CP447/9-1.438 1.438 1,782 250/280TP CP2528-1.251 1.251 236 445TP20 / 447/9TP CP447/9-1.501 1.501 1,782 320/360TP CP3236-1.001 1.001 252 445TP20 / 447/9TP CP447/9-1.688 1.688 1,782 320/360TP CP3236-1.188 1.188 252 445TP20 / 447/9TP CP447/9-1.751 1.751 1,782 320/360TP CP3236-1.251 1.251 252 445TP20 / 447/9TP CP447/9-1.938 1.938 1,782 320/360TP CP3236-1.438 1.438 252 445TP20 / 447/9TP CP447/9-2.001 2.001 1,782 320/360TP CP3236-1.501 1.501 252 445TP20 / 447/9TP CP447/9-2.063 2.063 1,782 400TP CP400-1.188 1.188 394 445TP20 / 447/9TP CP447/9-2.126 2.126 1,782 400TP CP400-1.251 1.251 394 445TP20 / 447/9TP CP447/9-2.188 2.188 1,782 400TP CP400-1.438 1.438 394 445TP20 / 447/9TP CP447/9-2.251 2.251 1,782 400TP CP400-1.501 1.501 394 445TP20 / 447/9TP CP447/9-2.376 2.376 1,782 400TP CP400-1.688 1.688 394 445TP20 / 447/9TP CP447/9-2.438 2.438 1,782 400TP CP400-1.751 1.751 394 445TP20 / 447/9TP CP447/9-2.501 2.501 1,782

NOTE: (1) Prices subject to change without notice.

Parts & Accessories B - 8 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 PARTS & ACCESSORIES Effective 05-01-18 Supercedes All Previous

STEADY BUSHING (FOR OPTIM® VH VERTICAL HOLLOWSHAFT MOTORS)

CATALOGUE CATALOGUE FRAME BX DIMENSION LIST PRICE FRAME BX DIMENSION LIST PRICE NUMBER NUMBER 210TP SB210-0.938 0.938 79 444/5TP SB444/5-1.188 1.188 158 210/250TP SB2125-0.751 0.751 79 444/5TP SB444/5-1.251 1.251 158 210/250TP SB2125-0.876 0.876 79 444/5TP SB444/5-1.438 1.438 158 210/250TP SB2125-1.001 1.001 79 444/5TP SB444/5-1.501 1.501 158 250TP SB250-1.188 1.188 79 444/5TP SB444/5-1.688 1.688 158 250TP SB250-1.251 1.251 79 444/5TP SB444/5-1.751 1.751 158 280TP SB280-0.751 0.751 95 444/5TP SB444/5-1.938 1.938 158 280TP SB280-0.876 0.876 95 445TP20 / 447/9TP SB447/9-1.438 1.438 173 280TP SB280-1.001 1.001 95 445TP20 / 447/9TP SB447/9-1.501 1.501 173 280TP SB280-1.188 1.188 95 445TP20 / 447/9TP SB447/9-1.688 1.688 173 280TP SB280-1.251 1.251 95 445TP20 / 447/9TP SB447/9-1.751 1.751 173 320TP SB320-1.001 1.001 110 445TP20 / 447/9TP SB447/9-1.938 1.938 173 320TP SB320-1.188 1.188 110 445TP20 / 447/9TP SB447/9-2.001 2.001 173 320TP SB320-1.251 1.251 110 445TP20 / 447/9TP SB447/9-2.063 2.063 173 320TP SB320-1.438 1.438 110 445TP20 / 447/9TP SB447/9-2.126 2.126 173 320TP SB320-1.501 1.501 110 445TP20 / 447/9TP SB447/9-2.188 2.188 173 360TP SB360-1.001 1.001 126 445TP20 / 447/9TP SB447/9-2.251 2.251 173 360TP SB360-1.188 1.188 126 445TP20 / 447/9TP SB447/9-2.376 2.376 173 360TP SB360-1.251 1.251 126 445TP20 / 447/9TP SB447/9-2.438 2.438 173 360TP SB360-1.438 1.438 126 445TP20 / 447/9TP SB447/9-2.501 2.501 173 360TP SB360-1.501 1.501 126 400TP SB400-1.188 1.188 142 400TP SB400-1.251 1.251 142 400TP SB400-1.438 1.438 142 400TP SB400-1.501 1.501 142 400TP SB400-1.688 1.688 142 400TP SB400-1.751 1.751 142

NOTE: (1) Prices subject to change without notice.

Parts & Accessories B - 9 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 PARTS & ACCESSORIES Effective 05-01-18 Supercedes All Previous

ALTERNATE P-FLANGE KITS (FOR OPTIM® VH VERTICAL HOLLOWSHAFT MOTORS)

FRAME CATALOGUE NUMBER LIST PRICE BASE DIM AJ AK 444/5TP PBVH444/5-16.5 1,640 16.5 14.75 13.5 444/5TP PBVH444/5-20 1,640 20 14.75 13.5 445TP20 PBVH445TP20-20 1,640 20 14.75 13.5 445TP20 PBVH445TP20-24.5 1,640 24.5 14.75 13.5 447/9TP PBVH447/9-20 1,766 20 14.75 13.5 447/9TP PBVH447/9-24.5 1,766 24.5 14.75 13.5

NOTE: (1) Prices subject to change without notice.

NRR BALL RATCHETS (FOR OPTIM® VH VERTICAL HOLLOWSHAFT MOTORS)

FRAME CATALOGUE NUMBER LIST PRICE 210TP NRR210TP 851 250TP NRR250TP 946 280TP NRR280TP 1,104 320TP NRR320TP 1,482 360TP NRR360TP 1,577 400TP NRR400TP 1,892 444/5TP NRR444/5TP 3,406 445TP20 / 447/9TP NRR440TP 3,547

NOTE: (1) Prices subject to change without notice.

Parts & Accessories B - 10 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FACTORY MODIFICATIONS Effective 05-01-18 Supercedes All Previous

MOTOR MODIFICATIONS

MOD. MODIFICATION LIST PRICE CODE SUMMARY 56 140 180 210 250 280 320 360 400 440 5000 5800 6800 C1A C-FLANGE - ODP 77 124 149 205 256 393 460 502 622 1,442 1,968 - - C1B C-FLANGE - TEFC 77 124 149 205 256 393 460 502 622 1,442 1,968 3,007 3,329 C2 C-FLANGE WITH INPRO/SEAL (ADV+) - 124 149 205 256 393 460 502 622 1,442 1,968 3,007 - C3A D-FLANGE - ODP ------C3B D-FLANGE - TEFC - 132 159 218 274 423 495 541 667 1,562 2,128 3,266 3,616 C4 D-FLANGE WITH INPRO/SEAL (ADV+) - 132 159 218 274 423 495 541 667 1,562 2,128 3,266 - C5A INPRO/SEAL DE 168 211 272 293 327 377 545 609 1,075 1,279 1,860 2,004 2,053 C5B INPRO/SEAL NDE 181 221 287 315 332 393 579 648 754 1,214 1,786 1,903 1,952 C5C SPECIAL INPRO/SEAL DE (ADV+ 841) - 175 255 261 296 339 440 491 1,115 1,322 1,612 1,807 - C5D SPECIAL INPRO/SEAL NDE (ADV+ 841) - 183 261 282 287 342 457 512 589 1,169 1,536 1,689 - C5E HYBRID INPRO/SEAL DE (ADV+ 841) - 372 438 562 630 763 900 988 1,271 1,602 1,945 2,189 - C5F HYBRID INPRO/SEAL NDE (ADV+ 841) - 381 444 465 536 720 919 1,009 1,088 1,378 1,821 2,024 - C6 F2 CONVERSION - 71 89 111 132 160 210 250 327 435 5,092 5,135 5,184 C7 SPACE HEATERS (CSA CERTIFIED) - 334 365 410 442 483 520 588 703 1,053 1,701 1,744 1,793 C8 THERMISTER 1/PH - 293 328 371 406 443 484 534 626 760 1,368 1,411 1,460 C9 KLIXONS 1/PH - 321 354 395 432 468 509 560 652 785 1,406 1,449 1,498 C10A AUXILIARY BOX - 658 668 683 694 707 490 505 556 626 - - - C10B AUXILIARY BOX F2 SIDE - 746 766 796 842 868 909 949 1,036 1,185 1,648 1,691 1,740 C11A INSULATED NDE BEARING - - - - - 2,173 2,573 2,863 1,592 2,181 3,680 3,930 3,979 C11B INSULATED DE & NDE BEARING - - - - - 3,267 3,725 4,079 3,447 4,890 7,684 8,725 8,774 C12 STAINLESS STEEL HARDWARE - 71 85 111 132 160 184 212 276 371 631 674 723 C13A WINDING RTD 2/PH - 1,761 1,781 1,811 1,872 1,898 2,013 2,182 2,259 2,367 2,936 2,979 3,028 C13B WINDING RTD 1/PH - 988 1,008 1,038 1,085 1,111 1,240 1,295 1,372 1,480 1,998 2,041 2,090 C14 BEARING RTD 1/BRG - - - - 1,987 2,041 2,095 2,162 2,267 2,403 2,883 2,926 2,975 C15A RTD AUXILIARY BOX - 577 587 602 613 626 639 787 838 908 - - - C15B RTD AUXILIARY BOX F2 SIDE - 956 976 1,006 1,094 1,120 1,146 1,248 1,325 1,433 2,274 2,317 2,366 C15C BTD BOX F2 SIDE ------2,263 2,306 2,355 C16 REMOVE FEET 216 246 322 403 511 584 710 1,103 1,321 1,570 - - - C17A OVERSIZED TERMINAL BOX - STD - 308 346 429 483 511 601 780 957 1,115 1,472 1,693 1,889 C17B OVERSIZED TERMINAL BOX - TYPE II ------2,775 2,968 3,011 3,060 C18 TERMINAL BLOCK MAIN TERMINAL BOX - 327 352 378 519 532 620 714 857 978 - - - C19 CONVERT BEARINGS: BALL TO ROLLER ------1,240 1,410 2,066 2,623 5,011 6,402 6,451 C20 CONVERT BEARINGS: ROLLER TO BALL ------855 959 1,357 2,110 4,558 5,887 5,936

NOTE: (1) Lead times vary depending on the modification requested. (2) All prices to be based on “Stock Product Modification Procedures #TWMI-M1”. (3) Auxiliary Boxes are always to be priced as separate mods. (4) Prices shown are TWMI’s list prices, standard motor multiplier applies for the motor being modified. (5) Please contact your TWMI representative for a discount when performing multiple modifications to one motor. (6) Please contact your TWMI representative for pricing on mods not listed. (7) Refer to Factory Modification Descriptions for more accurate details on each modification. (8) All modifications are to be performed by authorized TECO-Westinghouse modification centers in accordance with “Stock Product Modification Procedures #TWMI-M1”.

Factory Modifications B - 11 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FACTORY MODIFICATIONS Effective 05-01-18 Supercedes All Previous

MOTOR MODIFICATIONS

MOD. MODIFICATION LIST PRICE CODE SUMMARY 56 140 180 210 250 280 320 360 400 440 5000 5800 6800 C21A CUSTOM SHAFT - MODIFY EXISTING SHAFT 624 680 715 779 846 919 1,037 1,141 1,402 1,653 2,748 2,898 3,161 C21B CUSTOM SHAFT - REPLACE EXISTING SHAFT 1,567 1,597 1,867 2,149 2,423 3,203 4,236 5,532 6,139 7,202 19,186 20,233 22,280 STUB SHAFT FOR SHAFT MOUNTED C21C 441 471 491 563 626 708 787 910 1,043 1,204 2,321 2,471 2,733 ENCODERS C22 SPECIAL GREASE 227 280 341 371 496 522 650 739 816 924 1,419 1,462 1,511 C23 NAMEPLATE CHANGE 21 21 21 21 21 21 21 21 21 24 24 24 24 ADDITIONAL NAMEPLATE - INFORMATION C24 21 21 21 21 21 21 21 21 21 21 21 21 21 PLATE C25 GROUNDING PROVISION 96 111 121 136 184 197 210 276 327 397 566 609 658 C26A BREATHER DRAIN PLUGS 109 139 170 207 243 269 295 335 412 520 1,007 1,050 1,099 DRAIN HOLES DE (NO THREADS/BREATHER C26B 52 67 77 92 103 116 129 144 195 265 396 439 488 DRAINS) DRAIN HOLES NDE (NO THREADS/ C26C 80 110 130 160 182 208 234 274 351 459 849 892 941 BREATHER DRAINS) TROPICALIZATION- FUNGUS/CORROSION C27 99 139 211 241 314 340 417 457 586 694 1,135 1,178 1,227 PROTECTION C28 CHANGE ROTATION ------838 881 930 C29 CHANGE COOLING FAN (FAN NOT INCL.) 56 71 96 121 147 171 197 240 327 435 631 674 723 C30 JACKING BOLTS - 156 173 188 229 242 299 321 462 596 940 983 1,032 C31A DRIP COVER 226 245 268 292 384 440 498 558 592 939 - - - C31B DRIP COVER C/W VERTICAL LIFTING LUGS 684 702 773 841 955 1,034 1,115 1,220 1,278 1,738 - - -

C32 SUN-SHIELD QUOTE QUOTE QUOTE QUOTE QUOTE QUOTE QUOTE QUOTE QUOTE QUOTE QUOTE QUOTE QUOTE ROUTINE COMMERCIAL TEST AS PER C33A 349 364 374 389 560 573 667 682 812 963 - - - IEEE112 C33B VIBRATION TEST & REPORT AS PER IEEE841 173 188 198 213 301 314 389 404 600 670 1,146 1,189 1,238 C34 BALANCE ROTOR TO IEEE841 STANDARDS 377 407 450 504 570 631 691 778 889 1,076 2,998 3,041 3,090 C35A SHAFT GROUNDING BRUSH (CARBON TYPE) 199 214 247 262 404 417 492 507 - - - - - C35B SHAFT GROUND RING 282 297 335 378 479 568 695 787 1,034 1,303 1,782 2,129 2,178 C35C SHAFT GROUND SEAL (ADV+) - 345 407 523 588 709 840 921 1,361 1,603 1,930 2,175 - C35D SHAFT GROUND SEAL (OPTIM VH) - - 521 589 910 806 904 1,090 1,380 1,797 - - - C36A SPECIAL PAINT - COLOR (STANDARD PAINT) - 235 269 309 395 472 547 624 801 1,123 1,481 1,524 - C36B SPECIAL PAINT - EPOXY - 235 269 309 395 472 547 624 801 1,123 1,481 1,524 - C37 CONVERT TO 3 LEAD MOTOR 210 240 283 365 436 513 590 679 808 965 1,607 1,650 1,699 C38 EXTEND MAIN LEADS 332 377 450 521 613 708 1,090 1,241 1,372 1,533 - - - C39 CHANGE BEARINGS TO ZZ TYPE - 195 249 305 421 577 629 716 1,105 1,544 - - -

NOTE: (1) Lead times vary depending on the modification requested. (2) All prices to be based on “Stock Product Modification Procedures #TWMI-M1”. (3) Auxiliary Boxes are always to be priced as separate mods. (4) Prices shown are TWMI’s list prices, standard motor multiplier applies for the motor being modified. (5) Please contact your TWMI representative for a discount when performing multiple modifications to one motor. (6) Please contact your TWMI representative for pricing on mods not listed. (7) Refer to Factory Modification Descriptions for more accurate details on each modification. (8) All modifications are to be performed by authorized TECO-Westinghouse modification centers in accordance with “Stock Product Modification Procedures #TWMI-M1”.

Factory Modifications B - 12 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FACTORY MODIFICATIONS Effective 05-01-18 Supercedes All Previous

MOTOR MODIFICATIONS

MOD. MODIFICATION LIST PRICE CODE SUMMARY 56 140 180 210 250 280 320 360 400 440 5000 5800 6800 C40 DE-RATE HP 21 21 21 21 21 21 21 21 21 21 21 21 21 C41 RE-RATE TO 50HZ 21 21 21 21 21 21 21 21 21 21 21 21 21 C42 LOW TEMP -50°C - 550 621 666 801 842 981 1,098 1,214 1,563 2,316 2,359 2,408 C43A CONVERT IEEE READY TO IEEE 841 - 556 673 707 824 922 1,324 1,443 2,109 2,705 4,071 4,289 - C43B CONVERT STANDARD TEFC TO IEEE 841 - 1,468 1,732 1,899 2,309 2,585 3,209 3,575 4,543 5,583 9,533 9,750 - C44 LOCKED DE BRG 195 236 313 343 410 460 578 662 784 916 1,581 1,624 1,673 C45 REWIND MOTOR 1,592 1,926 2,243 2,437 2,671 3,722 6,142 7,889 11,932 16,683 - - - CONNECT MOTOR FOR WYE-DELTA C46 485 500 510 754 994 1,235 1,477 1,720 2,000 2,527 3,801 3,844 3,893 STARTING C47 VERTICAL LIFTING LUGS 485 500 557 617 652 688 723 785 857 1,042 - - - C48 MODIFY TO IP66 (ADV+ 841 Motors) - 158 226 297 365 436 562 693 857 1,042 - - - C49 OIL MIST LUBRICATION - - - - 1,788 2,229 2,883 3,325 3,803 4,515 - - - C50 VIBRATION SENSOR PROVISIONS - - - - 459 472 532 547 645 715 - - - C51 AUX BLOWER - - - - 2,451 2,938 3,426 3,915 4,440 4,985 - - -

NOTE: (1) Lead times vary depending on the modification requested. (2) All prices to be based on “Stock Product Modification Procedures #TWMI-M1”. (3) Auxiliary Boxes are always to be priced as separate mods. (4) Prices shown are TWMI’s list prices, standard motor multiplier applies for the motor being modified. (5) Please contact your TWMI representative for a discount when performing multiple modifications to one motor. (6) Please contact your TWMI representative for pricing on mods not listed. (7) Refer to Factory Modification Descriptions for more accurate details on each modification. (8) All modifications are to be performed by authorized TECO-Westinghouse modification centers in accordance with “Stock Product Modification Procedures #TWMI-M1”.

HAZARDOUS LOCATION MODIFICATIONS

MOD. MODIFICATION LIST PRICE CODE SUMMARY 56 140 180 210 250 280 320 360 400 440 5000 5800 6800 H1 CSA CERTIFIED DIVISION 1 SPACE HEATERS - 951 982 1,027 1,060 1,099 1,298 1,365 1,481 1,830 - - - H2 F2 CONVERSION XP - 259 290 335 419 458 573 639 793 939 - - - H3 INSTALL C-FLANGE XP - 267 312 371 551 639 690 823 1,342 1,412 - - - H4 NAMEPLATE CHANGE HAZLOC - 58 58 58 58 58 109 109 109 111 - - - EXPLOSION PROOF ADDER HA - 618 618 618 618 618 778 778 778 778 - - - (WHEN APPROVED)

NOTE: (1) All modifications are to be performed by authorized TECO-Westinghouse modification centers in accordance with “Stock Product Modification Procedures #TWMI-M1”.

Factory Modifications B - 13 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FACTORY MODIFICATION DESCRIPTIONS Effective 05-01-18 Supercedes All Previous

MOTOR MODIFICATION DESCRIPTIONS

MOD. MODIFICATION SUMMARY DESCRIPTION CODE C1A C-FLANGE - ODP Remove DE bracket and install C-Flange on ODP motor: modification price includes the C-Flange. C1B C-FLANGE - TEFC Remove DE bracket and install C-Flange on TEFC motor: modification price includes the C-Flange. Remove DE bracket and Inpro/Seal; install C-Flange with Inpro/Seal on TEFC motor: modification C2 C-FLANGE WITH INPRO/SEAL (ADV+) price includes the C-Flange. C3A D-FLANGE - ODP Remove DE bracket and install D-Flange on ODP motor: modification price includes the D-Flange. C3B D-FLANGE - TEFC Remove DE bracket and install D-Flange on TEFC motor: modification price includes the D-Flange. Remove DE bracket and Inpro/Seal; install D-Flange with Inpro/Seal on TEFC motor: modification C4 D-FLANGE WITH INPRO/SEAL (ADV+) price includes the D-Flange. Remove DE bracket, machine shaft opening and install Inpro/Seal: modification price includes C5A INPRO/SEAL DE Inpro/Seal. Remove NDE bracket, machine shaft opening and install Inpro/Seal: modification price includes C5B INPRO/SEAL NDE Inpro/Seal. Remove DE Inpro/Seal and install new special purpose Inpro/Seal. Use for vertical seal or special C5C SPECIAL INPRO/SEAL DE (ADV+ 841) seal: modification price includes Inpro/Seal. Remove NDE Inpro/Seal and install new special purpose Inpro/Seal. Use for vertical seal or special C5D SPECIAL INPRO/SEAL NDE (ADV+ 841) seal: modification price includes Inpro/Seal. Remove DE inpro/seal and install hybrid stainless/alumunim inpro/seal: modification price C5E HYBRID INPRO/SEAL DE (ADV+ 841) includes seal. Remove NDE inpro/seal and install hybrid stainless/alumunim inpro/seal: modification price C5F HYBRID INPRO/SEAL NDE (ADV+ 841) includes seal. Convert terminal box location from standard F1 to F2, or F2 to F1, depending on the product line. on medium voltage motors, The auxiliary terminal boxes will be on the opposite side as the main C6 F2 CONVERSION terminal box as standard. If the requirement is to have all terminal boxes on either the F1 or F2 side, please specify. Install wire wound rubber space heater(s) with leads terminated in main terminal box; if auxiliary C7 SPACE HEATERS (CSA CERTIFIED) terminal box is required see mod C10. Standard voltage is 115V; however other voltages are available. Heaters are CSA certified for Class I, Division 2 areas. Install three PTC thermistors (155°c), one per phase, on the winding end turns with leads brought C8 THERMISTER 1/PH out to main terminal box; if auxiliary terminal box is required see mod C10. Install three normally closed thermostats (140°c), one per phase connected in series, on the winding C9 KLIXONS 1/PH end turns with leads brought out to the main terminal box; if auxiliary terminal box is required see mod C10. Mount auxiliary terminal box on NDE side of the main terminal box. Includes box and terminal strip C10A AUXILIARY BOX with four terminals. Mount auxiliary terminal box on F2 side of the motor. Includes box and terminal strip with four C10B AUXILIARY BOX F2 SIDE terminals. Remove standard NDE bearing and replace with an electrically insulating bearing to eliminate stray C11A INSULATED NDE BEARING electric currents. Remove standard DE & NDE bearings and replace with electrically insulating bearings to eliminate C11B INSULATED DE & NDE BEARING stray electric currents. C12 STAINLESS STEEL HARDWARE Remove existing plated hardware and replace with stainless steel. Install six 100Ω platinum surface mount RTD’s, two per phase, on the winding end turns with leads C13A WINDING RTD 2/PH brought out to the main terminal box; if RTD auxiliary terminal box is required see mod C15. Install three 100Ω platinum surface mount RTD’s, one per phase, on the winding end turns with C13B WINDING RTD 1/PH leads brought out to the main terminal box; if RTD auxiliary terminal box is required see mod C15. Install two 100Ω platinum bearing RTD’s, one per bearing with leads brought out to the main C14 BEARING RTD 1/BRG terminal box; if RTD auxiliary terminal box is required see mod C15.

Factory Modifications Descriptions B - 14 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FACTORY MODIFICATION DESCRIPTIONS Effective 05-01-18 Supercedes All Previous

MOTOR MODIFICATION DESCRIPTIONS

MOD. MODIFICATION SUMMARY DESCRIPTION CODE Mount RTD auxiliary terminal box on DE side of the main terminal box. Includes box and two C15A RTD AUXILIARY BOX terminal strips with 12 terminals each. Mount RTD auxiliary terminal box on F2 side of the motor. Includes box and two terminal strips with C15B RTD AUXILIARY BOX F2 SIDE 12 terminals each. Mount BTD auxiliary terminal box on F2 side of the motor. Includes box and one terminal strips with C15C BTD BOX F2 SIDE 12 terminals each. Remove feet off horizontal mount T-Frame motor to create a round body type motor. Vertical lifting C16 REMOVE FEET lugs can be added at additional cost. Replace existing terminal box with an oversized main terminal box. Pricing is based on the terminal C17A OVERSIZED TERMINAL BOX - STD box that is standard for the next larger frame size. Price included box and adaptor plate. C17B OVERSIZED TERMINAL BOX - TYPE II Replace existing terminal box with an oversized nema Type II main terminal box.

C18 TERMINAL BLOCK MAIN TERMINAL BOX Install IEC style terminal block in the main terminal box and connect for requested voltage.

Convert standard bearing on DE from ball bearing to roller bearing. Lock the DE to contain C19 CONVERT BEARINGS: BALL TO ROLLER DE Roller Bearing Convert standard bearing on DE from roller bearing to ball bearing, machine work is required C20 CONVERT BEARINGS: ROLLER TO BALL allow for thermal growth. Machine NDE to relieve NDE Bearing. Modify existing shaft to meet customer requirements. A drawing must be submitted and approved CUSTOM SHAFT - C21A by both TWMI and the customer. This mod includes TS shafts, shortened shafts, smaller diameter MODIFY EXISTING SHAFT shafts etc. CUSTOM SHAFT - Replace existing shaft to meet customer requirements. A drawing must be submitted and approved C21B REPLACE EXISTING SHAFT by both TWMI and the customer. This mod includes 4140 shafts, double shafts, JM shafts etc. STUB SHAFT FOR SHAFT MOUNTED Modify NDE with stub shaft and provisions to mount encoder. (Encoder not included, contact TWMI C21C ENCODERS for pricing if required). Remove standard grease from bearings, end brackets and inlet tubes. Purge and repack with C22 SPECIAL GREASE specified grease type. Add new nameplate displaying approved data changes such as new voltage and frequency, revised C23 NAMEPLATE CHANGE HP and service factor, higher or lower ambient temperature, etc. Use this for adder for XP motors when modifications are being performed in addition to the nameplate change (H4). ADDITIONAL NAMEPLATE- C24 Add second data plate with customer part number, order number, or other data. INFORMATION PLATE Drill and tap the motor frame to accept ground lug. All motors have a grounding lug inside the C25 GROUNDING PROVISION main lead box as a standard. Lug not included in price. C26A BREATHER DRAIN PLUGS Install stainless steel breather drain plugs where required. DRAIN HOLES DE C26B Drill drain holes in DE for vertical mounting. (No threads/breather drains) (NO THREADS/BREATHER DRAINS) DRAIN HOLES NDE C26C Drill drain holes in NDE for vertical mounting. (No threads/breather drains) (NO THREADS/BREATHER DRAINS) TROPICALIZATION - C27 Spray the internal windings, rotor and end brackets with a fungus proof anti-corrosion coating. FUNGUS/CORROSION PROTECTION C28 CHANGE ROTATION Replace unidirectional cooling fan to achieve opposite direction of rotation. CHANGE COOLING FAN Replace standard fan with non sparking fan, cast iron fan or other material requested to meet C29 (FAN NOT INCLUDED) customer’s requirements. Fan not included in price. Drill and tap two holes in the motor feet diagonally from one another to provide provisions for C30 JACKING BOLTS jacking bolts. C31A DRIP COVER Install fabricated steel drip cover on NDE for vertical motors. DRIP COVER C/W VERTICAL C31B Install fabricated steel drip cover and lifting lugs on NDE for vertical motors. LIFTING LUGS

Factory Modifications Descriptions B - 15 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FACTORY MODIFICATION DESCRIPTIONS Effective 05-01-18 Supercedes All Previous

MOTOR MODIFICATION DESCRIPTIONS

MOD. MODIFICATION SUMMARY DESCRIPTION CODE Install sun-shield over motor to protect from excessive heating caused by over exposure to the C32 SUN-SHIELD sun, typically for use in desert climates. Sun-shield will be priced per motor, contact your TWMI representative for more information. ROUTINE COMMERCIAL TEST AS C33A Perform Routine Commercial (unwitnessed) testing as per IEEE112 and provide report. PER IEEE112 VIBRATION TEST & REPORT AS C33B Perform vibration test and send report with motor as outlined in IEEE841 standard. PER IEEE841 BALANCE ROTOR TO C34 Balance rotor to IEEE841 specifications. IEEE841 STANDARDS SHAFT GROUNDING BRUSH C35A Install carbon brush type shaft grounding device. (CARBON TYPE) C35B SHAFT GROUND RING Install shaft grounding ring on DE to reduce or eliminate shaft currents. C35C SHAFT GROUND SEAL (ADV+) Install shaft grounding seal on DE to reduce or eliminate shaft currents. C35D SHAFT GROUND SEAL (OPTIM VH) Install shaft grounding seal inside motor to reduce or eliminate shaft currents. SPECIAL PAINT - COLOUR C36A Paint motor with standard type paint with customer specified color. (STANDARD PAINT) C36B SPECIAL PAINT - EPOXY Standard paint finish will be changed to Epoxy paint system (e.g. Advantage Plus Epoxy Paint). C37 CONVERT TO 3 LEAD MOTOR Re-connect motor to 3 leads. Extend existing leads to customer specified length. The splice will be made behind the terminal box C38 EXTEND MAIN LEADS so it is not seen. C39 CHANGE BEARINGS TO ZZ TYPE Remove bearings and install ZZ type double sheilded bearings. C40 DE-RATE HP De-rate motor HP to lower value, second data plate will be installed showing de-rated motor data. C41 RE-RATE TO 50HZ Re-rate motor to 50Hz operation, second data plate will be installed showing re-rated motor data. Modifiy motor for low temperature operation down to -50°C. Includes spaceheaters terminated in C42 LOW TEMP -50°C main box, low temp grease and new nameplate. Convert Adv+ IEEE Ready motor to Adv+ IEEE 841 specs. Includes inpro seals, vibration test & report, C43A CONVERT IEEE READY TO IEEE 841 new nameplate & labor. Convert standard TEFC motor to Adv+ IEEE 841 specs. Includes inpro seals, paint, hardware, C43B CONVERT STANDARD TEFC TO IEEE 841 vibration test & report, new nameplate & labor. C44 LOCKED DE BRG Lock DE bearing <.000" endplay. Rewing motor with class H insulation or special requirements. (Polyrex EM is rated for 170'C - no C45 REWIND MOTOR need to change grease for class H) CONNECT MOTOR FOR WYE-DELTA C46 Re-connect motor internally to allow for wye-delta starting. *Approval required STARTING C47 VERTICAL LIFTING LUGS Install vertical lifting lugs on horizontal motor. C48 MODIFY TO IP66 (ADV+ 841 MOTORS) Add epoxy potting to leads and silicon sealant on the endbells and connection box gaskets. C49 OIL MIST LUBRICATION Convert bearing grease system to oil mist lubrication system. C50 VIBRATION SENSOR PROVISIONS Add provisions for vibration monitors C51 AUX BLOWER Install auxilliary blower for use with VFD

Factory Modifications Descriptions B - 16 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FACTORY MODIFICATION DESCRIPTIONS Effective 05-01-18 Supercedes All Previous

HAZARDOUS LOCATION MODIFICATION DESCRIPTIONS

MOD. MODIFICATION SUMMARY DESCRIPTION CODE Install wire wound rubber space heater(s) that are CSA certified for division 1, with leads terminated CSA CERTIFIED DIVISION 1 SPACE H1 in main terminal box. Standard voltage is 115V; however other voltages are available. Please specify HEATERS voltage when ordering. All heaters are single phase. H2 F2 CONVERSION XP Convert terminal box location from standard F1 to F2 on TEXP motor. Remove DE bracket and install c-flange on TEXP motor: modification price includes the c-flange & H3 INSTALL C-FLANGE XP a new nameplate. Add new nameplate displaying approved data changes such as new voltage and frequency, revised H4 NAMEPLATE CHANGE HAZLOC HP and service factor, higher or lower ambient temperature, etc. This adder is to be used when no other modifications are being done to the motor, otherwise use C23. EXPLOSION PROOF ADDER Additional cost to perform standard modifications to XP motors. Due to CSA regulations only certain HA (WHEN APPROVED) modifications can be done on XP motors, contact your TWMI representative for more information.

Factory Modifications Descriptions B - 17 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FACTORY MODIFICATION REFERENCE Effective 05-01-18 Supercedes All Previous

BEARING CROSS REFERENCE TABLE

RS TEFC OPTIM® TEFC ADVANTAGE PLUS OPTIM® TEXP MAX-HT FRAME DE NDE DE NDE DE NDE DE NDE DE NDE 56 140T 6205ZZ 6204ZZ 6205ZZ 6205ZZ 6205ZC3 6205ZC3 6205ZZ 6205ZZ 180T 6206ZZC3 6205ZZC3 6306ZZ 6306ZZ 6306ZC3 6306ZC3 6306ZZ 6306ZZ 210T 6208ZZC3 6206ZZC3 6308ZZ 6306ZZ 6308ZC3 6306ZC3 6308ZZ 6306ZZ 250T 6309ZZ 6307ZZ 6309ZC3 6307ZC3 6309ZZ 6307ZZ 280T 6311ZZ 6310ZZ 6311ZC3 6310ZC3 6311ZZ 6310ZZ 280TS 6211C3 6211C3 6311ZC3 6310ZC3 6211C3 6211C3 320T 6312 6212 6312ZC3 6212ZC3 6312 6212 320TS 6312C3 6212C3 6312ZC3 6212ZC3 6312C3 6212C3 360T 6313 6213 6313ZC3 6213ZC3 6313 6213 360TS 6312C3 6212C3 6312ZC3 6212ZC3 6312C3 6212C3 400T 6317 6313 6317C3 6313ZC3 6317 6313 400TS 6313C3 6313C3 6313C3 6313ZC3 6313C3 6313C3 444/5T 6318 6316 6318C3 6316C3 NU318 6318 444/5TS 6314C3 6314C3 6314C3 6314C3 6313C3 6313C3 447/9T 6320 6316 6320C3 6316C3 447/9TS 6314C3 6314C3 6314C3 6314C3 5000A 6315C3 6315C3 6315C3 6315C3 5000BC 6324C3 6320 6324C3 6320C3 NU324C3 6320 5800A 5800BC 6326C3 6322 6326C3 6322C3 NU326C3 6322 6800A 6800BC 6326C3 6322 450C 500C 560C

GLOBAL XPE OPTIM® ODP ROLLED STEEL ODP GLOBAL ODP FRAME DE NDE DE NDE DE NDE DE NDE 56 140T 6205ZZ 6205ZZ 6205ZZ 6204ZZ 180T 6306ZZ 6306ZZ 6206ZZC3 6205ZZC3 210T 6308ZZ 6306ZZ 6208ZZC3 6206ZZC3 250T 6310ZZ 6309ZZ 6309ZZC3 6208ZZC3 280T 6311ZZ 6310ZZ 6311ZZC3 6211ZZC3 280TS 6212C3 6211C3 6311ZZC3 6211ZZC3 320T 6213 6213 320TS 6213C3 6213C3 360T 6314 6213 360TS 6313C3 6213C3 400T 6317 6317 400TS 6313C3 6313C3 444/5T 6318 6316 6318 6318 444/5TS 6314C3 6314C3 6314C3 6314C3 447/9T 6320 6318 6320 6318 447/9TS 6315C3 6315C3 6315C3 6315C3 5000A 6315C3 6315C3 6324 6320 6315C3 6315C3 5000BC 6324 6320 6324 6320 5800A 6315C3 6315C3 6315C3 6315C3 5800BC 6326 6322 6326 6322 6800A 6315C3 6315C3 6800BC 6326 6322 6326 6322 450C 6324 6322 500C 6326 6324/C3 VL2071 560C 6330 6326/C3 VL0241

Factory Modifications Reference B - 18 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FEATURES

MODEL: FLUXMASTER 50 MICRO AC DRIVE DESCRIPTION: A compact, low cost AC Drive that is easy to program and Effective 05-01-18 ideal for OEM’s. Supercedes All Previous

APPLICATIONS • Mixing • Food Processing • Fans • AC Contactor Replacement • Small Conveyors • Pumps

FEATURES • .25 to 1HP, 115V, 50/60Hz Single Phase Input • .25 to 3HP, 230V, 50/60Hz Single Phase Input • 2 and 3HP, 230V, 50/60Hz Three Phase Input • 1 to 3HP, 460V, 50/60Hz Three Phase Input • 0 to 200Hz Output Frequency Range • 3 Digit LED Built-In Keypad • Constant Torque Rated • Pulse Width Modulation (PWM) Utilizing IGBT Technology • Selectable Reference Input • 4 Digital Inputs 2 Are Multifunction • 1 Analog Output (0-10V) • 1 Relay Class Digital Output • 3 V/Hz Control Patterns • 0 to 999 Seconds Programmable Acceleration and Deceleration Time • Built-In Brake Transistor on Most Models • 200% Instantaneous Over Current Capabilities • 150% Over Current for One Minute • Motor Overload Protection • Fault History • Torque Boost Function • UL, cUL and CE Approved

Control Products - FLUXMASTER 50 C - 1 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES FLUXMASTER 50 MICRO AC DRIVE Open Chassis (Panel Mount) Micro AC Inverter Simple Programming Space Saving Design Effective 05-01-18 VOLTAGE: 150% Overload Rating for Demanding Applications Supercedes All Previous 115V / 230V / 460V

115V 1-PHASE INPUT / 230V 3-PHASE OUTPUT

HP DRIVE AMPS DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER CONSTANT TORQUE CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE FM50-1P2-C 0.25 1.4 5.20 2.84 4.65 2 223 FM50-1P5-C 0.5 2.3 5.20 2.84 4.65 2 238 FM50-101-C 1 4.2 5.20 2.84 4.65 2 270

230V 1-PHASE INPUT / 230V 3-PHASE OUTPUT

HP DRIVE AMPS DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER CONSTANT TORQUE CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE FM50-2P2-C 0.25 1.4 5.20 2.84 4.65 2 223 FM50-2P5-OC 0.5 2.3 5.20 2.84 4.65 2 238 FM50-201-OC 1 4.2 5.20 2.84 4.65 2 270

230V 1-PHASE OR 3-PHASE INPUT / 230V 3-PHASE OUTPUT

HP DRIVE AMPS DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER CONSTANT TORQUE CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE FM50-202-C 2 7.5 5.63 4.65 6.77 5 325 FM50-203-C 3 10.5 5.63 4.65 6.77 5 415

460V 3-PHASE INPUT / 460V 3-PHASE OUTPUT

HP DRIVE AMPS DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER CONSTANT TORQUE CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE FM50-401-C 1 2.3 5.63 4.65 6.77 4 350 FM50-402-C 2 3.8 5.63 4.65 6.77 4 385 FM50-403-C 3 5.2 5.63 4.65 6.77 4 440

FLUXMASTER 50 PERIPHERALS CATALOGUE NUMBER DESCRIPTION LIST PRICE FM50-DIN-201 Din Rail Kit 15

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - FLUXMASTER 50 C - 2 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 NEMA 4 & NEMA 4 WITH OPERATOR DEVICES FEATURES MODEL: FLUXMASTER 50 MICRO AC DRIVE NEMA 4 & NEMA 4 with Operator Devices Effective 05-01-18 DESCRIPTION: A compact, low cost AC Drive that is easy to program and Supercedes All Previous NEMA 4 NEMA 4 WITH ideal for OEM’s. OPERATOR DEVICES

APPLICATIONS • Mixing • Food Processing • Fans • Beverage • Small Conveyors • Pharmaceutical

FEATURES NEMA 4 Enclosure (Indoor) NEMA 4 with Operator Devices (Indoor) • .5 to 1HP, 115V, 50/60Hz Single Phase Input • .25 to 3 HP, 230V, 50/60Hz Single Phase Input • .5 to 3HP, 230V, 50/60Hz Single Phase Input • 2 and 3 HP, 230V, 50/60Hz Three Phase Input • 2 and 3HP, 230V, 50/60Hz Three Phase Input • 1 to 3 HP, 460V, 50/60Hz Three Phase Input • 1 to 3HP, 460V, 50/60Hz Three Phase Input • Fully Rated Disconnect Switch • 0 to 200Hz Output Frequency Range • Forward - Off - Reverse Selector Switch • 3 Digit LED Built-In Keypad • Built-In Potentiometer • Constant Torque Rated • 0 to 200 Hz Output Frequency Range • Pulse Width Modulation (PWM) Utilizing IGBT Technology • 3 Digit LED Built-In Keypad • Selectable Reference Input • Constant Torque Rated • 4 Digital Inputs 2 Are Multifuction • Pulse Width Modulation (PWM) Utilizing IGBT Technology • 1 Analog Output (0-10V) • Selectable Reference Input • 1 Relay Class Digital Output • 4 Digital Inputs 2 Are Multifuction • 3 V/Hz Control Patterns • 1 Analog Output (0-10V) • 0 to 999 Seconds Programmable Acceleration and • 0 to 999 Seconds Programmable Acceleration and Deceleration Time Deceleration Time • Built-In Brake Transistor on Most Models • 3 V/Hz Control Patterns • 200% Instantaneous Over Current Capabilities • 1 Relay Class Digital Output • 150% Over Current for One Minute • Built-In Brake Transistor on Most Models • Motor Overload Protection • 200% Instantaneous Over Current Capabilities • Fault History • 150% Over Current for One Minute • Torque Boost Function • Motor Overload Protection • UL, cUL and CE Approved • Fault History • Torque Boost Function • UL, cUL and CE approved

Control Products - FLUXMASTER 50 NEMA 4 & NEMA 4 WITH OPERATOR DEVICES C - 3 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023

NEMA 4 WITH DIGITAL KEYPAD LIST PRICES FLUXMASTER 50 MICRO AC DRIVE NEMA 4 (Indoors) Micro AC Inverter Simple Programming 150% Overload Rating For Demanding Applications Effective 05-01-18 VOLTAGE: Supercedes All Previous 115V / 230V / 460V

115V 1-PHASE INPUT / 230V 3-PHASE OUTPUT

HP DRIVE AMPS DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER CONSTANT TORQUE CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE FM50-1P5-N4 0.5 2.3 8.49 5.54 6.70 8 428 FM50-101-N4 1 4.2 8.49 5.54 6.70 8 455

230V 1-PHASE INPUT / 230V 3-PHASE OUTPUT

HP DRIVE AMPS DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER CONSTANT TORQUE CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE FM50-2P5-N4 0.5 2.3 8.49 5.54 6.70 8 435 FM50-201-N4 1 4.2 8.49 5.54 6.70 8 475

230V 1-PHASE OR 3-PHASE INPUT / 230V 3-PHASE OUTPUT

HP DRIVE AMPS DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER CONSTANT TORQUE CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE FM50-202-N4 2 7.5 11.62 9.14 7.11 14 655 FM50-203-N4 3 10.5 11.62 9.14 7.11 14 730

460V 3-PHASE INPUT / 460V 3-PHASE OUTPUT

HP DRIVE AMPS DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER CONSTANT TORQUE CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE FM50-401-N4 1 2.3 11.62 9.14 7.11 13 713 FM50-402-N4 2 3.8 11.62 9.14 7.11 14 795 FM50-403-N4 3 5.2 11.62 9.14 7.11 14 880

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - FLUXMASTER 50 NEMA 4 WITH DIGITAL KEYPAD C - 4 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 NEMA 4 WITH OPERATOR DEVICES LIST PRICES FLUXMASTER 50 MICRO AC DRIVE NEMA 4 (Indoors) Micro AC Inverter Simple Programming 150% Overload Rating For Demanding Applications Effective 05-01-18 VOLTAGE: Digital Keypad Supercedes All Previous 230V / 460V Disconnect Switch, Speed Potentiometer and Forward - Off - Reverse Selector Switch

230V 1-PHASE INPUT / 230V 3-PHASE OUTPUT

HP DRIVE AMPS DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER CONSTANT TORQUE CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE FM50-2P2-N4FS 0.25 1.4 8.49 5.54 7.19 8 538 FM50-2P5-N4FS 0.5 2.3 8.49 5.54 7.19 8 550 FM50-201-N4FS 1 4.2 8.49 5.54 7.19 8 575

230V 1-PHASE OR 3-PHASE INPUT / 230V 3-PHASE OUTPUT

HP DRIVE AMPS DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER CONSTANT TORQUE CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE FM50-202-N4FS 2 7.5 11.62 9.14 8.33 14 750 FM50-203-N4FS 3 10.5 11.62 9.14 8.33 14 840

460V 3-PHASE INPUT / 460V 3-PHASE OUTPUT

HP DRIVE AMPS DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER CONSTANT TORQUE CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE FM50-401-N4FS 1 2.3 11.62 9.14 8.33 13 838 FM50-402-N4FS 2 3.8 11.62 9.14 8.33 14 903 FM50-403-N4FS 3 5.2 11.62 9.14 8.33 14 1,003

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - FLUXMASTER 50 NEMA 4 WITH OPERATOR DEVICE C - 5 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FEATURES

MODEL: L510 MEDIUM DUTY MICRO AC DRIVE DESCRIPTION: A compact, low cost and versatile AC Drive that is easy to Effective 05-01-18 program and ideal for OEM’s. Supercedes All Previous

APPLICATIONS • Mixing • AC Contactor Replacement • Fans • Pumps • Small Conveyors

FEATURES • Chassis Style Enclosure (IP 20) • Sensorless Vector or V/Hz with Auto Torque Boost Feature • 0.25 to 1HP, 115V, 50/60Hz, 1-Phase • 0.25 to 3HP, 230V, 50/60Hz, 1-Phase • 0.5 to 3HP, 230V, 50/60Hz, 3-Phase • 1 to 3 HP, 460V, 50/60Hz, 3-Phase • Extensive Diagnostic and Monitoring Capabilities • Micro Drive with Din Rail Option • PID Control • 0 to 200Hz Speed Range • 24VDC, 50mA External Sensor Supply Built-in • 8 Preset Speeds • Multi-function Analog Input/Output • Built-in RS485 Modbus • RJ45 Interface for PC and Copy Module • cUL and CE Approved

Control Products - L510 C - 6 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES L510 MEDIUM DUTY MICRO AC DRIVE Open Chassis Micro AC Inverter V/Hz and Sensorless Vector PID Control Effective 05-01-18 VOLTAGE: Supercedes All Previous 115V / 230V / 460V

115V 1-PHASE INPUT / 230V 3-PHASE OUTPUT CONSTANT CONSTANT DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER TORQUE TORQUE LBS PRICE HP AMPS HEIGHT WIDTH DEPTH L510-1P2-H1-U .25 1.8 5.55 2.83 5.48 2 309 L510-1P5-H1-U .50 2.6 5.55 2.83 5.48 2 317 L510-101-H1-U 1 4.3 5.67 4.65 5.80 3.5 342

230V 1-PHASE INPUT / 230V 3-PHASE OUTPUT CONSTANT CONSTANT DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER TORQUE TORQUE LBS PRICE HP AMPS HEIGHT WIDTH DEPTH L510-2P2-H1-U .25 1.8 5.55 2.83 5.48 2 291 L510-2P5-H1-U .50 2.6 5.55 2.83 5.48 2 306 L510-201-H1-U 1 4.3 5.55 2.83 5.48 2 313 L510-202-H1-U 2 7.5 5.67 4.65 5.80 3.5 430 L510-203-H1-U 3 10.5 5.67 4.65 5.80 3.5 515

230V 3-PHASE INPUT / 230V 3-PHASE OUTPUT CONSTANT CONSTANT DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER TORQUE TORQUE LBS PRICE HP AMPS HEIGHT WIDTH DEPTH L510-2P5-H3-U .50 2.6 5.55 2.83 5.48 2 306 L510-201-H3-U 1 4.3 5.55 2.83 5.48 2 313 L510-202-H3-U 2 7.5 5.67 4.65 5.80 3.5 423 L510-203-H3-U 3 10.5 5.67 4.65 5.80 3.5 471

460V 3-PHASE INPUT / 460V 3-PHASE OUTPUT CONSTANT CONSTANT DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER TORQUE TORQUE LBS PRICE HP AMPS HEIGHT WIDTH DEPTH L510-401-H3-U 1 2.3 5.67 4.65 5.80 3.5 434 L510-402-H3-U 2 3.8 5.67 4.65 5.80 3.5 478 L510-403-H3-U 3 5.2 5.67 4.65 5.80 3.5 577

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - L510 C - 7 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023

FEATURES

MODEL: E510 MEDIUM DUTY COMPACT AC DRIVE

DESCRIPTION: A versatile AC Drive that can control today’s demanding Effective 05-01-18 motor driven applications, this highly flexible drive has Supercedes All Previous multiple control modes and built-in PLC functionality.

APPLICATIONS • Mixing • Machine Tools • Pumps (Centrifugal, Positive Displacement, Metering, etc.) • Conveyors • Fans • Extrusion and Injection Molding • Packaging Machines • Crushers/ Grinders • Compressors

FEATURES • Control Modes for V/F, and Sensorless Vector • Simple PLC Function Built-in • .5 to 20 HP (CT), 230V, 50/ 60Hz, 3-Phase • 1 to 25 HP (CT), 460V, 50/ 60Hz, 3-Phase • Conformal Coating on PC Boards • LED Keypad with 5 Digits • Flexible Input/ Output Configurations that Accept Normally Open or Normally Closed Signals • 0 to 599 Hz Speed Range • PID Control • Diagnostics Registers for Troubleshooting • Built-in Modbus Protocol via (RJ45 Interface) • UL, cUL, and CE Approved

Control Products - E510 C - 8 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 NEMA 4/4X WITH KEYPAD LIST PRICES E510 MEDIUM DUTY COMPACT AC DRIVE Conformal Coating V/Hz and Sensorless Vector PID Control Effective 05-01-18 VOLTAGE: Supercedes All Previous 230V / 460V

230V 3-PHASE INPUT / 230V 3-PHASE OUTPUT

HP DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER DRIVE AMPS CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE E510-205-H3N4-U 5 17.5 13.3 7.8 8.6 13.2 1,732 E510-208-H3N4-U 7.5 26 18.4 8.8 9.8 28 1,970 E510-210-H3N4-U 10 35 18.4 8.8 9.8 28 2,273 E510-215-H3N4-U 15 48 18.4 8.8 9.8 28 2,829 E510-220-H3N4-U 20 64 18.4 8.8 9.8 28 2,872

460V 3-PHASE INPUT / 460V 3-PHASE OUTPUT

HP DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER DRIVE AMPS CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE E510-401-H3N4-U 1 2.3 9.8 6 7.2 6.4 951 E510-402-H3N4-U 2 3.8 9.8 6 7.2 6.4 985 E510-403-H3N4-U 3 5.2 13.3 7.8 8.6 13.2 1,317 E510-405-H3N4-U 5 8.8 13.3 7.8 8.6 13.2 1,507 E510-408-H3N4-U 7.5 13 18.4 8.8 9.8 28 1,941 E510-410-H3N4-U 10 17.5 18.4 8.8 9.8 28 2,175 E510-415-H3N4-U 15 24 18.4 8.8 9.8 28 2,385 E510-420-H3N4-U 20 32 18.4 8.8 9.8 28 2,829 E510-425-H3N4-U 25 40 18.4 8.8 9.8 28 2,975

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted. (3) HP sizing based on Constant Torque applications. (4) Indoor use only. (5) Drive comes with Keypad only, no disconnect, no speed pot.

Control Products - E510 NEMA 4/4X WITH KEYPAD C - 9 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023

NEMA 4/4X WITH KEYPAD AND SPEEDPOT LIST PRICES E510 MEDIUM DUTY COMPACT AC DRIVE Conformal Coating V/Hz and Sensorless Vector PID Control Effective 05-01-18 VOLTAGE: Supercedes All Previous 230V / 460V

230V 1-PHASE OR 3-PHASE INPUT / 230V 3-PHASE OUTPUT

HP DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER DRIVE AMPS CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE E510-2P5-HN4R-U 0.5 2.6 9.8 6 7.9 6.4 829 E510-201-HN4R-U 1 4.5 9.8 6 7.9 6.4 878 E510-202-HN4R-U 2 7.5 13.3 7.8 9.3 13.2 1,073 E510-203-HN4R-U 3 10.5 13.3 7.8 9.3 13.2 1,293

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted. (3) HP sizing based on Constant Torque applications. (4) Indoor use only. (5) Drive comes with Keypad and speed pot, no disconnect.

Control Products - E510 NEMA 4/4X WITH KEYPAD AND SPEEDPOT C - 10 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 NEMA 4/4X WITH KEYPAD, SPEEDPOT AND DISCONNECT LIST PRICES E510 MEDIUM DUTY COMPACT AC DRIVE Conformal Coating V/Hz and Sensorless Vector PID Control Effective 05-01-18 VOLTAGE: Supercedes All Previous 230V / 460V

230V 1-PHASE INPUT / 230V 3-PHASE OUTPUT

HP DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER DRIVE AMPS CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE E510-2P5-H1FN4S-U 0.5 2.6 9.8 6 7.9 6.4 870 E510-201-H1FN4S-U 1 4.5 9.8 6 7.9 6.4 925 E510-202-H1FN4S-U 2 7.5 13.3 7.8 9.3 13.2 1,220 E510-203-H1FN4S-U 3 10.5 13.3 7.8 9.3 13.2 1,330

460V 3-PHASE INPUT / 460V 3-PHASE OUTPUT

HP DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER DRIVE AMPS CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE E510-401-H3FN4S-U 1 2.3 9.8 6 7.9 6.4 1,100 E510-402-H3FN4S-U 2 3.8 9.8 6 7.9 6.4 1,250 E510-403-H3FN4S-U 3 5.2 13.3 7.8 9.3 13.2 1,500 E510-405-H3FN4S-U 5 8.8 13.3 7.8 9.3 13.2 1,650 E510-408-H3FN4S-U 7.5 13 18.4 8.8 10.5 28 2,100 E510-410-H3FN4S-U 10 17.5 18.4 8.8 10.5 28 2,300 E510-415-H3FN4S-U 15 24 18.4 8.8 10.5 28 2,600

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted. (3) HP sizing based on Constant Torque applications. (4) Indoor use only. (5) Drive comes with Keypad, speed pot, disconnect.

Control Products - E510 NEMA 4/4X WITH KEYPAD, SPEEDPOT AND DISCONNECT C - 11 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 N3 FEATURES MODEL: N3 COMPACT AC DRIVE

DESCRIPTION: A compact, low cost and versatile AC Drive that can Effective 05-01-18 operate in constant torque, variable torque. V/Hz and Supercedes All Previous sensorless vector modes for maximum application flexibilty.

APPLICATIONS • Fan and Pump Systems • Centrifugal Applications • Conveyors • OEM Products • Mixers

FEATURES • 1 to 40HP, 230V, 50/60Hz Three Phase Input • 1 to 75HP, 460V, 50/60Hz Three Phase Input • 0 to 400Hz Output Frequency Range • 4 Digit LED Built-In Keypad • Constant Torque Rated • Pulse Width Modulation (PWM) Utilizing IGBT Technology • Programmable Reference Input • 6 Digital Inputs • 1 Analog Output • 3 Programmable Digital Outputs • 0 to 3600 Seconds Programmable Acceleration and Deceleration Time • Built-In Brake Transistor Up to 20 HP • 150% Over Current for One Minute • Motor Overload Protection • Fault History • Operation Time • Torque Boost Parameter • PID Control with Sleep and Wakeup Mode • Sensorless Vector or V/Hz Mode • 8 Preset Speed Setting • Communication Cards Available RS-485, RS-232 • Setup Software • Options: Copy Unit • Programming: Basic and Advanced • 8 LED Lights for Operator Indication • Autotuning Function • “S” Curves for Acceleration and Deceleration • DC Injection Braking • Skip Frequencies • 8 Step Programmable Acceleration and Deceleration • 2 Programmable/Select Acceleration and Deceleration Ramps • Built-In BACnet IP • cUL and CE Approved

Control Products - N3 C - 12 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 N3 NEMA 1 LIST PRICES N3 COMPACT AC DRIVE Compact AC Inverter V/Hz and Sensorless Vector PID Control with Sleep and Wakeup Mode “S” Curves for Accel and Decel Effective 05-01-18 VOLTAGE: Parameter Copy Unit Available Supercedes All Previous 230V N3-Link Configuration Software

230V 3-PHASE INPUT / 230V 3-PHASE OUTPUT

HP DRIVE AMPS DIMENSIONS (APPROX.) APPROX. WT. LIST CATALOGUE NUMBER CONSTANT TORQUE CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE N3-201-C 1 4.5 6.42 3.54 5.79 3 388 N3-202-C 2 7.5 6.42 3.54 5.79 3 465 N3-203-C 3 10.5 7.36 5.04 5.83 4 625 N3-205-C 5 17.5 7.36 5.04 5.83 5 703 N3-207-C 7.5 26 10.24 7.32 7.68 13 1,043 N3-210-C 10 35 10.24 7.32 7.68 13 1,180 N3-215-N1 15 48 14.20 10.43 9.74 27 1,778 N3-220-N1 20 64 14.20 10.43 9.74 27 2,020 N3-225-N1 25 80 14.20 10.43 9.74 29 2,675 N3-230-N1 30 96 25.50 10.73 12.00 67 3,610 N3-240-N1 40 130 25.50 10.73 12.00 67 4,788

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - N3 NEMA 1 C - 13 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 N3 NEMA 1 & PERIPHERALS LIST PRICES N3 COMPACT AC DRIVE & PERIPHERALS Compact AC Inverter V/Hz and Sensorless Vector PID Control with Sleep and Wakeup Mode “S” Curves for Accel and Decel Effective 05-01-18 VOLTAGE: Parameter Copy Unit Available Supercedes All Previous 460V N3-Link Configuration Software

460V 3-PHASE INPUT / 460V 3-PHASE OUTPUT

HP DRIVE AMPS DIMENSIONS (APPROX.) APPROX. WT. LIST CATALOGUE NUMBER CONSTANT TORQUE CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE N3-401-C 1 2.3 6.42 3.54 5.79 3 455 N3-402-C 2 3.8 6.42 3.54 5.79 3 518 N3-403-C 3 5.2 7.38 5.04 5.83 4 665 N3-405-C 5 8.8 7.38 5.04 5.83 4 768 N3-407-C 7.5 13 10.24 7.32 7.68 13 1,093 N3-410-C 10 17.5 10.24 7.32 7.68 13 1,180 N3-415-C 15 25 10.24 7.32 7.68 13 1,403 N3-420-N1 20 32 14.20 10.43 9.74 27 2,075 N3-425-N1 25 40 14.20 10.43 9.74 29 2,600 N3-430-N1 30 48 14.20 10.43 9.74 29 2,900 N3-440-N1 40 64 25.50 10.73 12.00 67 3,813 N3-450-N1 50 80 25.50 10.73 12.00 67 4,675 N3-460-N1 60 96 29.60 12.30 15.20 102 5,350 N3-475-N1 75 128 29.60 12.30 15.20 102 6,135

N3 PERIPHERALS CATALOGUE NUMBER DESCRIPTION LIST PRICE SIF-485 COMMUNICATIONS INTERFACE RS485 54 SIF-232 RS232 INTERFACE CARD WITH CABLE TO PC 45 SIF-MP MEMORY PAK 27 SW3001 REMOTE WIRE FOR KEYPAD (1.0M) 94 SW3002 REMOTE WIRE FOR KEYPAD (2.0M) 98 SW3003 REMOTE WIRE FOR KEYPAD (3.0M) 103 SNA201 NEMA 1 BOX FOR FRAME 1*** 27 SNA202 NEMA 1 BOX FOR FRAME 2*** 29 SNA203 NEMA 1 BOX FOR FRAME 3*** 38

*** FRAME 1 201-C, 202-C, 401-C, 402-C *** FRAME 2 203-C, 205-C, 403-C, 405-C *** FRAME 3 207-C, 210-C, 407-C, 410-C, 415-C

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - N3 NEMA 1 & PERIPHERALS C - 14 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FEATURES

MODEL: F510 FAN AND PUMP AC DRIVE DESCRIPTION: A versatile AC Drive that is easily configured and handles Effective 05-01-18 almost any fan, blower or centrifugal pump application. Supercedes All Previous

APPLICATIONS • Fans • Centrifugal Pumps • Blowers • HVAC Industries • Water and Wastewater Industries • Irrigation

FEATURES • Control Modes for V/F, Sensorless Vector • Application Macros for Quick Start-up. Macros Available for: Fans, Pumps, HVAC • Built-in PLC as Standard • LCD Keypad • PID Control with advanced diagnostics and sleep mode • 5 to 150HP (Variable Torque), 230V, 50/60Hz, 3-Phase • 5 to 250HP (Variable Torque), 460V, 50/60Hz, 3-Phase • Conformal Coating on PC Boards • Diagnostics Registers for Troubleshooting • Flexible Input/ Output Configurations that Incorporate Normally Open or Normally Closed Signals • 0 to 400Hz Speed Range • Built-in RS485 Communications (Modbus, BACNet and Metasys are Standard Protocols) • Enhanced Design for Smoother and Quieter Motor Operation • Pulse Output and Pulse Follower • PTC Input Available for Direct Thermal Protection of the Motor • Thermal Management on the Heat Sink for Overtemperature Fault Avoidance • Select Between Closed Loop Speed and Torque Control in Vector Mode • Built-in Brake Transistor on Models F510-2005-C3 thru F510-2030-C3 also F510-4005-C3 thru F510-4040-C3 • Built-in DC Link Reactor on Models F510-2060-C3 thru F510-2150-C3 also F510-4100-C3 thru F510-4250-C3 • cUL and CE Approved

Control Products - F510 C - 15 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES F510 FAN & PUMP AC DRIVE A versatile AC Drive that is easily configured and handles almost any fan, blower or centrifugal pump application. Effective 05-01-18 VOLTAGE: Supercedes All Previous 230V / 460V

230V 3-PHASE INPUT / 230V 3-PHASE OUTPUT

HP DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER DRIVE AMPS VARIABLE TORQUE HEIGHT WIDTH DEPTH LBS PRICE F510-2005-C3-U 5 14.5 12.4 5.51 6.97 8.4 934 F510-2008-C3-U 7.5 21.0 12.4 5.51 6.97 8.4 952 F510-2010-C3-U 10 30.0 11.81 8.27 8.46 13.6 1,353 F510-2015-C3-U 15 40.0 11.81 8.27 8.46 13.6 1,500 F510-2020-C3-U 20 56.0 14.17 10.43 8.86 22.0 1,882 F510-2025-C3-U 25 69.0 14.17 10.43 8.86 22.0 2,352 F510-2030-C3-U 30 79.0 14.17 10.43 8.86 22.0 2,786 F510-2040-C3-U 40 110.0 20.67 11.18 9.92 66.1 4,116 F510-2050-C3-U 50 138.0 20.67 11.18 9.92 66.1 4,822 F510-2060-C3-U* 60 169.0 22.83 13.54 11.81 89.3 6,865 F510-2075-C3-U* 75 200.0 22.83 13.54 11.81 89.3 7,542 F510-2100-C3-U* 100 250.0 31.10 18.08 12.78 162.8 9,879 F510-2125-C3-U* 125 312.0 31.10 18.08 12.78 162.8 12,348 F510-2150-C3-U* 150 400.0 39.37 27.16 16.14 405 24,696

460V 3-PHASE INPUT / 460V 3-PHASE OUTPUT

HP DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER DRIVE AMPS VARIABLE TORQUE HEIGHT WIDTH DEPTH LBS PRICE F510-4005-C3-U 5 9.2 12.4 5.51 6.97 8.8 912 F510-4008-C3-U 7.5 11.1 12.4 5.51 6.97 8.8 1,004 F510-4010-C3-U 10 17.5 12.4 5.51 6.97 8.8 1,470 F510-4015-C3-U 15 23.0 11.81 8.27 8.46 13.6 1,529 F510-4020-C3-U 20 31.0 11.81 8.27 8.46 13.6 2,018 F510-4025-C3-U 25 38.0 14.17 10.43 8.86 22 2,375 F510-4030-C3-U 30 44.0 14.17 10.43 8.86 22 2,952 F510-4040-C3-U 40 54.0 14.17 10.43 8.86 22 3,176 F510-4050-C3-U 50 72.0 20.67 11.18 9.92 66.1 4,050 F510-4060-C3-U 60 88.0 20.67 11.18 9.92 66.1 5,057 F510-4075-C3-U 75 103.0 20.67 11.18 9.92 66.1 5,557 F510-4100-C3-U* 100 145.0 22.83 13.70 11.81 89.3 6,575 F510-4125-C3-U* 125 165.0 22.83 13.70 11.81 89.3 9,996 F510-4150-C3-U* 150 208.0 31.10 18.08 12.78 163.1 12,584 F510-4215-C3-U* 200 250.0 31.10 18.08 12.78 163.1 14,348 F510-4250-C3-U* 250 328.0 31.10 18.08 12.78 163.1 20,996

* Models Are Open Chassis, NEMA 1 Kits Available. NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - F510 C - 16 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 PERIPHERALS LIST PRICES F510 FAN AND PUMP AC DRIVE PERIPHERALS A versatile AC Drive that is easily configured and handles almost any fan, blower or centrifugal pump application. Effective 05-01-18 Supercedes All Previous

F510 PERIPHERALS CATALOGUE NUMBER DESCRIPTION LIST PRICE JN5-CB-01M EXTENSION WIRE (1M) 38 JN5-CB-02M EXTENSION WIRE (2M) 50 JN5-CB-03M EXTENSION WIRE (3M) 75 JN5-CB-05M EXTENSION WIRE (5M) 100 JN5-CM-USB USB CABLE TO CONNECT TO A PC 125 JN5-CU COPY UNIT 190 JN5-NK-A06 F510 FRAME 6 NEMA 1 KIT (F510-2060-C3 AND A510-2075-C3), (A510-4100-C3 AND A510-4125-C3) 690 JN5-NK-A07 F510 FRAME 7 NEMA 1 KIT (A510-2100-C3 AND A510-2125-C3), (A510-4150-C3 TO A510-4250-C3) 940 JN5-NK-A08 F510 FRAME 8 NEMA 1 KIT (A510-2150-C3) 1,000 JN5-OP-F02 LCD OPERATOR 190 JN5-OP-F03 IP 20 LCD HOA OPERATOR 100 JN5-OP-A03 BLANK OPERATOR 100 JN5-CM-PDP PROFIBUS COMMUNICATION INTERFACE MODULE (GATEWAY EXTERNAL) 500 JN5-CM-DNET DEVICENET CARD (GATEWAY EXTERNAL) 300 JN5-CM-CAN CANOPAN CARD (GATEWAY EXTERNAL) 300 JN5-IO-8DO 1 TO 8 DIGITAL OUTPUT CARD 225 JNEP-16-F REMOTE ANALOG OPERATOR 170

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - F510 PERIPHERALS C - 17 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 FEATURES

MODEL: A510 HEAVY DUTY AC DRIVE

DESCRIPTION: A versatile AC Drive that can control todays demanding Effective 05-01-18 motor driven applications. This highly flexible drive has Supercedes All Previous multiple control modes and a built-in PLC.

APPLICATIONS • Mixing • Machine Tools • Pumps (Centrifugal, Positive Displacement, Metering, etc.) • Conveyors • Fans • Extrusion and Injection Molding • Packaging Machines • Compressors • Winders / Unwinders • Crushers / Grinders • Crane / Hoist / Elevator

FEATURES • Control Modes for V/F, V/F with PG Feedback, Sensorless Vector, and Closed Loop Vector • Simple PLC Function Built-in • Advanced Regenerative Load Handling Capability • 1 to 100HP (CT), 230V, 50/60Hz, 3-Phase • 1 to 200HP (CT), 460V, 50/60Hz, 3-Phase • 1 to 200HP (CT) 575V, 50/60Hz, 3-Phase • 15 to 250HP (CT) 690V, 50/60Hz, 3-Phase • Conformal Coating on PC Boards • LCD Keypad That Can Be Remotely Mountable • Flexible Input/Output Configurations That Accept Normally Open or Normally Closed Signals • 0 to 400Hz Speed Range • PID Control • Diagnostics Registers for Troubleshooting • Built-in RS485 Communications (Modbus) • Enhanced Design for Smother and Quieter Motor Operation • Pulse Output and Pulse Follower • Select Between Closed Loop Speed and Torque Control in Vector Mode • Built-in Brake Transistor on Models (A510-2001-C thru A510-2025-C3), (A510-4001-C3 thru A510-4040-C3) and (A510-5001-C3 thru A510-6040-C3) • Built-in DC Link Reactor on Models (A510-2050-C3 thru A510-2100-C3), (A510-4075-C3 thru A510-4215-C3) and (A510-6100-C3 thru A510-6250-C3) • cUL and CE Approved

Control Products - A510 C - 18 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES A510 HEAVY DUTY AC DRIVE A versatile AC Drive that can control todays demanding motor driven applications. This highly flexible drive has multiple control modes and a built-in PLC. Effective 05-01-18 VOLTAGE: Supercedes All Previous 230V

230V 1-PHASE OR 3-PHASE INPUT / 230V 3-PHASE OUTPUT

HP DRIVE AMPS DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER CONSTANT TORQUE CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE A510-2001-C-U 1 5.0 9.61 5.12 5.91 6 687 A510-2002-C-U 2 8.0 9.61 5.12 5.91 6 720 A510-2003-C-U 3 11.0 12.40 5.51 6.97 9 886

230V 3-PHASE INPUT / 230V 3-PHASE OUTPUT

HP DRIVE AMPS DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER CONSTANT TORQUE CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE A510-2005-C3-U 5 17.5 12.40 5.51 6.97 9 930 A510-2008-C3-U 7.5 25.0 12.40 5.51 6.97 9 1,351 A510-2010-C3-U 10 33.0 11.80 8.27 8.46 14 1,462 A510-2015-C3-U 15 47.0 14.20 10.43 8.86 22 1,937 A510-2020-C3-U 20 60.0 14.20 10.43 8.86 22 2,269 A510-2025-C3-U 25 73.0 14.20 10.43 8.86 22 2,801 A510-2030-C3-U 30 85.0 20.70 11.20 9.92 67 4,328 A510-2040-C3-U 40 115.0 20.70 11.20 9.92 67 5,424 A510-2050-C3-U* 50 145.0 22.80 13.54 11.81 102 6,863 A510-2060-C3-U* 60 180.0 22.80 13.54 11.81 102 8,025 A510-2075-C3-U* 75 215.0 31.10 18.10 12.80 194 9,741 A510-2100-C3-U* 100 283.0 31.10 18.10 12.80 194 12,176

* Models Are Open Chassis, NEMA 1 Kits Available.

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - A510 C - 19 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES A510 HEAVY DUTY AC DRIVE A versatile AC Drive that can control todays demanding motor driven applications. This highly flexible drive has multiple control modes and a built-in PLC. Effective 05-01-18 VOLTAGE: Supercedes All Previous 460V

460V 3-PHASE INPUT / 460V 3-PHASE OUTPUT

HP DRIVE AMPS DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER CONSTANT TORQUE CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE A510-4001-C3-U 1 3.4 9.61 5.12 5.91 6 709 A510-4002-C3-U 2 4.2 9.61 5.12 5.91 6 742 A510-4003-C3-U 3 5.5 9.61 5.12 5.91 6 897 A510-4005-C3-U 5 9.2 12.40 5.51 6.97 9 997 A510-4008-C3-U 7.5 14.8 12.40 5.51 6.97 9 1,450 A510-4010-C3-U 10 18.0 11.80 8.27 8.46 14 1,556 A510-4015-C3-U 15 24.0 11.80 8.27 8.46 14 1,993 A510-4020-C3-U 20 31.0 11.80 8.27 8.46 20 2,380 A510-4025-C3-U 25 39.0 14.20 10.43 8.86 22 2,967 A510-4030-C3-U 30 45.0 14.20 10.43 8.86 22 3,155 A510-4040-C3-U 40 60.0 20.70 11.20 9.92 67 4,184 A510-4050-C3-U 50 75.0 20.70 11.20 9.92 67 5,048 A510-4060-C3-U 60 91.0 20.70 11.20 9.92 67 5,756 A510-4075-C3-U 75 118.0 20.70 11.20 9.92 78 6,309 A510-4100-C3-U* 100 150.0 22.80 13.70 11.81 103 9,851 A510-4125-C3-U* 125 180.0 22.80 13.70 11.81 103 12,508 A510-4150-C3-U* 150 216.0 31.10 18.10 12.80 195 14,500 A510-4215-C3-U* 200 295.0 31.10 18.10 12.80 195 19,038

* Models Are Open Chassis, NEMA 1 Kits Available.

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - A510 C - 20 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES A510 HEAVY DUTY AC DRIVE A versatile AC Drive that can control todays demanding motor driven applications. This highly flexible drive has multiple control modes and a built-in PLC. Effective 05-01-18 VOLTAGE: Supercedes All Previous 575V

575V 3-PHASE INPUT / 575V 3-PHASE OUTPUT

HP DRIVE AMPS DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER CONSTANT TORQUE CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE A510-5001-C3-U 1 1.7 12.4 5.51 7.0 8.8 1,084 A510-5002-C3-U 2 3 12.4 5.51 7.0 8.8 1,176 A510-5003-C3-U 3 4.2 12.4 5.51 7.0 8.8 1,250 A510-5005-C3-U 5 6.6 11.9 8.30 8.5 13.6 1,323 A510-5008-C3-U 7.5 9.9 11.9 8.30 8.5 13.6 1,397 A510-5010-C3-U 10 11.4 11.9 8.30 8.5 13.6 1,470 A510-6020-C3-U 15 19 14.2 10.50 8.9 22.0 2,389 A510-6025-C3-U 20 22 14.2 10.50 8.9 22.0 3,069 A510-6030-C3-U 25 27 14.2 10.50 8.9 22.0 3,198 A510-6040-C3-U 30 34 14.2 10.50 8.9 22.0 4,043 A510-6050-C3-U 40 42 20.7 11.30 10.0 66.1 4,962 A510-6060-C3-U 50 54 20.7 11.30 10.0 66.1 6,064 A510-6075-C3-U 60 62 20.7 11.30 10.0 66.1 6,799 A510-6100-C3-U* 75 86 22.9 13.60 11.9 102.0 8,574 A510-6125-C3-U* 100 99 22.9 13.60 11.9 102.0 11,907 A510-6150-C3-U* 125 131 22.9 13.60 11.9 102.0 13,690 A510-6215-C3-U* 150 163 31.2 18.10 12.8 200.0 19,295 A510-6250-C3-U* 200 192 31.2 18.10 12.8 200.0 21,500

* Models Are Open Chassis, NEMA 1 Kits Available.

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - A510 C - 21 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 LIST PRICES A510 HEAVY DUTY AC DRIVE A versatile AC Drive that can control todays demanding motor driven applications. This highly flexible drive has multiple control modes and a built-in PLC. Effective 05-01-18 VOLTAGE: Supercedes All Previous 690V

690V 3-PHASE INPUT / 690V 3-PHASE OUTPUT

HP DRIVE AMPS DIMENSIONS APPROX. WT. LIST CATALOGUE NUMBER CONSTANT TORQUE CONSTANT TORQUE HEIGHT WIDTH DEPTH LBS PRICE A510-6015-C3-U 15 15 14.2 10.5 8.9 22 2,132 A510-6020-C3-U 20 19 14.2 10.5 8.9 22 2,389 A510-6025-C3-U 25 22 14.2 10.5 8.9 22 3,069 A510-6030-C3-U 30 27 14.2 10.5 8.9 22 3,198 A510-6040-C3-U 40 34 14.2 10.5 8.9 22 4,043 A510-6050-C3-U 50 42 20.7 11.3 10.0 66.1 4,962 A510-6060-C3-U 60 54 20.7 11.3 10.0 66.1 6,064 A510-6075-C3-U 75 62 20.7 11.3 10.0 89.1 6,799 A510-6100-C3-U* 100 86 22.9 13.6 11.9 102.0 8,574 A510-6125-C3-U* 125 99 22.9 13.6 11.9 102.0 11,907 A510-6150-C3-U* 150 131 22.9 13.6 11.9 102.0 13,690 A510-6215-C3-U* 200 163 31.2 18.1 12.8 200.0 19,295 A510-6250-C3-U* 250 192 31.2 18.1 12.8 200.0 21,500

* Models Are Open Chassis, NEMA 1 Kits Available.

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - A510 C - 22 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 PERIPHERALS LIST PRICES A510 HEAVY DUTY AC DRIVE PERIPHERALS A versatile AC Drive that can control todays demanding motor driven applications. This highly flexible drive has multiple control modes and a built-in PLC. Effective 05-01-18 Supercedes All Previous

A510 PERIPHERALS CATALOGUE NUMBER DESCRIPTION LIST PRICE JN5-CB-01M EXTENSION WIRE (1M) 38 JN5-CB-02M EXTENSION WIRE (2M) 50 JN5-CB-03M EXTENSION WIRE (3M) 75 JN5-CB-05M EXTENSION WIRE (5M) 100 JN5-CM-USB USB CABLE TO CONNECT TO A PC 125 JN5-CU COPY UNIT 190 A510 FRAME 6 NEMA 1 KIT (A510-2050-C3 and A510-2060-C3), (A510-4100-C3 and A510-4125-C3), JN5-NK-A06 690 (A510-6100-C3 to A510-6150-C3) A510 FRAME 7 NEMA 1 KIT (A510-2075-C3 and A510-2100-C3), (A510-4150-C3 and A510-4215-C3), JN5-NK-A07 940 (A510-6215-C3 to A510-6250-C3) JN5-OP-A02 LCD OPERATOR 190 JN5-OP-A03 BLANK OPERATOR 100 JN5-PG-L LINE DRIVER SPEED FEEDBACK CARD 190 JN5-PG-O OPEN COLLECTOR SPEED FEEDBACK CARD 250 JN5-PG-PM LINE DRIVER SPEED FEEDBACK CARD 190 JN5-CM-PDP PROFIBUS COMMUNICATION INTERFACE MODULE (GATEWAY EXTERNAL) 500

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - A510 PERIPHERALS C - 23 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 SP2000 FEATURES

Effective 05-01-18 Supercedes All Previous

APPLICATIONS • Mixing • Fans • Pumps (Centrifugal, Positive Displacement, Metering etc.) • Conveyors • Crushers • Mechanical Drive Upgrade / Replacement • Process Lines • Hammer Mill, Ball Mill

FEATURES • Power Range; 5HP to 4000HP • Wide Power Supply Voltage Range; 230-690Vac, 50/60Hz, 3-Phase • Enclosure, IP00, IP20 • V/Hz, Sensorless Vector, Closed Loop Vector and Regenerative • Complete Communications Offering • 200% Torque Available • 0-1000 Hz Speed Range • 5 Languages; English, Italian, Spanish, Portuguese, German • Start-Up Wizard Included • Carrier Frequency 2.0 to 16Khz • 4 Integrated Multi-Function Programmable Logic Blocks • Programming and Monitoring Software Available • 4 Separate Acceleration / Deceleration Ramps • 3 Separate Analog Inputs • 15 Multi-speed Setting • PID with Sleep and Wake modes • 3 Analog Outputs • Built-In Timer Function • Programmable Digital Outputs • 3 Separate Motor Configurations • 8 Digital Inputs • Built-In Brake Chopper on Many Models • 4 Line Display with 11 LED Indicators • Fault History Log • Keypad Copy Module • Auto Tune Function • S Curve Selection for Acceleration and Deceleration • Skip Frequencies • 3-Year Warranty • cUL, CE, Gost, C-Tick Approved

Control Products - SP2000 C - 24 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 SP2000 SP2000 - OVERLOAD SELECTION CHART

SP2000 - OVERLOAD SELECTION CHART OVERLOAD OVERLOAD APPLICATIONS APPLICATIONS LGT STD HVY STG LGT STD HVY STG Agitator X Hydraulic Power Jack (Inj. Mould Machines) X X Atomizer X Extruders X Bottle Washer X Grinder X Centrifuge X Hydraulic Power Pack X Chipper X Mill X Piston Compressor Loaded X Ball Mill X Piston Compressor Unloaded X Hammer Mill X Screw Compressor Loaded X Roller Mill X Screw Compressor Unloaded X Mixer X Conveyor Belt X Palletiser X Conveyor Roller X Planer X Conveyor Screw X Bore Pumps X Crusher (Cone) X Centrifugal Pumps X Crusher (Jaw) X Positive Displacement Pumps X Crusher (Rotary) X Slurry Pumps X X Crusher (Vertical Impact) X Pulper X Debarker X Rotary Table X Dryer X X Sander X Dust Collector X Bandsaw X Edger X Circular Saw X Damped Axial Fan X Separator X Undamped Axial Fan X Vibrating Screen X Centrifugal Damped Fan X Shredder X Undamped Centrifugal Fan X Slicer X High Pressure Fan X Tumbler X Elevators X X Spinner X Hoists & Cranes X Industrial Washers X Screw Injection Moulding Machines X X Looms X Mechanical Presses X X Axe Control X X Drills X X Shears X X Mills X Winding / Unwinding Machines X X Forming Machines X X Drawplates X X

Control Products - SP2000 - OVERLOAD SELECTION CHART C - 25 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 SP2000 SINUS PENTA LIST PRICES SP2000 - SINUS PENTA 3 Year Warranty Flexible I/O Heat Sink Segregation Conformal Coating on all boards Effective 05-01-18 VOLTAGE: Full Metal Casing Supercedes All Previous 480V Wide Range of Communication Modules

480V 3-PHASE IP20/IP00

OVERLOAD CAPACITY DIMENSIONS FRAME (APPROX.) APPROX. LIST CATALOGUE NUMBER HP HP HP HP I-NOM I-MAX SIZE LIGHT STANDARD HEAVY STRONG WT. LBS PRICE 120% 140% 175% 200% HEIGHT WIDTH DEPTH S05 SP2000-0005-4T-BIK2 7.5 6 5 4 10.5 11.5 13.5 7 7 16 2,381 S05 SP2000-0007-4T-BIK2 10 7.5 6 5 12.5 13.5 13.5 7 7 16 2,446 S05 SP2000-0014-4T-BIK2 12.5 12.5 12.5 10 16.5 25 13.5 7 7 16 2,748 S12 SP2000-0016-4T-BIK2 20 15 15 12.5 27 30 16 8.5 9 28 3,038 S12 SP2000-0020-4T-BIK2 25 20 20 15 30 36 16 8.5 9 28 3,241 S12 SP2000-0025-4T-BIK2 30 25 25 20 41 48 16 8.5 9 28 3,683 S12 SP2000-0030-4T-BIK2 30 30 30 25 41 56 16 8.5 9 28 3,819 S12 SP2000-0036-4T-BIK2 50 40 40 35 60 72 16 8.5 9 28 4,498 S15 SP2000-0040-4T-BIK2 60 50 40 35 72 80 18.5 9 13 50 5,402 S15 SP2000-0049-4T-BIK2 65 60 50 40 80 96 18.5 9 13 50 5,874 S20 SP2000-0060-4T-BIK2 75 75 60 50 88 112 24 11 13 80 6,674 S20 SP2000-0067-4T-BIK2 90 90 70 55 103 118 24 11 13 80 7,100 S20 SP2000-0074-4T-BIK2 100 95 75 60 120 144 24 11 13 80 7,786 S20 SP2000-0086-4T-BIK2 125 100 90 75 135 155 24 11 13 80 8,435 S30 SP2000-0113-4T-BIK2 150 125 100 88 180 200 29.5 12 16.5 112 11,783 S30 SP2000-0129-4T-BIK2 170 150 125 100 195 215 29.5 12 16.5 112 14,569 S30 SP2000-0150-4T-BIK2 180 180 150 125 215 270 29.5 12 16.5 112 14,569 S30 SP2000-0162-4T-BIK2 200 200 180 150 240 290 29.5 12 16.5 112 14,847 S41 SP2000-0180-4T-XIK0 270 250 220 165 300 340 35 20 16 267 20,171 S41 SP2000-0202-4T-XIK0 300 300 250 200 345 420 35 20 16 267 21,299 S41 SP2000-0217-4T-XIK0 340 340 300 220 375 460 35 20 16 267 23,230 S41 SP2000-0260-4T-XIK0 380 380 350 270 425 560 35 20 16 267 24,374 *S51 SP2000-0313-4T-XIK0 430 430 350 300 480 600 35 23 16 311 29,409 *S51 SP2000-0367-4T-XIK0 570 510 430 340 550 680 35 23 16 311 33,517 *S51 SP2000-0402-4T-XIK0 610 610 550 430 680 850 35 23 16 311 35,284 *S60 SP2000-0457-4T-XIK0 610 610 510 450 720 880 52 35 21 573 55,999 *S60 SP2000-0524-4T-XIK0 680 680 610 510 800 960 52 35 21 573 58,953 *S65 SP2000-0598-4T-XIK0 760 760 680 550 900 1100 55 39 22 970 92,644 *S65 SP2000-0748-4T-XIK0 860 860 760 680 1000 1300 55 39 22 970 101,414 *S65 SP2000-0831-4T-XIK0 1090 1090 860 760 1200 1440 55 39 22 970 110,167

* Input and Output reactor is required for these models. I-NOM: Continuous rated current of the inverter I-MAX: Maximum current produced by the inverter for 120 seconds every 20 minutes up to S30 and 60 seconds every 10 minutes for S41 and larger

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - SP2000 C - 26 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 SP2000 SINUS PENTA LIST PRICES SP2000 - SINUS PENTA 3 Year Warranty Flexible I/O Heat Sink Segregation Conformal Coating on all boards Effective 05-01-18 VOLTAGE: Full Metal Casing Supercedes All Previous 575V Wide Range of Communication Modules

575V 3-PHASE IP20/IP00

OVERLOAD CAPACITY DIMENSIONS FRAME (APPROX.) APPROX. LIST CATALOGUE NUMBER HP HP HP HP I-NOM I-MAX SIZE LIGHT STANDARD HEAVY STRONG WT. LBS PRICE 120% 140% 175% 200% HEIGHT WIDTH DEPTH S12 SP2000-0003-5T-XA2K2 5.5 5.5 4 4 7 8.5 16 8.5 9 23 2,850 S12 SP2000-0004-5T-XA2K2 7.5 7.5 5.5 5.5 9 11 16 8.5 9 23 2,978 S12 SP2000-0006-5T-XA2K2 10 10 7.5 5.5 11 13.5 16 8.5 9 23 3,220 S12 SP2000-0012-5T-XA2K2 12.5 10 10 7.5 13 16 16 8.5 9 23 3,386 S12 SP2000-0018-5T-XA2K2 15 15 12.5 10 17 21 16 8.5 9 23 3,506 S14 SP2000-0019-5T-BA2K2 20 15 15 12.5 21 25 21 11 10 41 5,265 S14 SP2000-0021-5T-BA2K2 25 20 20 15 25 30 21 11 10 41 5,544 S14 SP2000-0022-5T-BA2K2 30 30 25 20 33 40 21 11 10 41 5,855 S14 SP2000-0024-5T-BA2K2 40 35 30 25 40 48 21 11 10 41 5,991 S14 SP2000-0032-5T-BA2K2 50 50 40 35 52 63 21 11 10 41 6,901 S22 SP2000-0042-5T-BA2K2 60 60 50 40 60 72 33 11 14 119 10,815 S22 SP2000-0051-5T-BA2K2 75 75 60 50 80 96 33 11 14 119 11,510 S22 SP2000-0062-5T-BA2K2 90 90 75 60 85 110 33 11 14 119 13,198 S22 SP2000-0069-5T-BA2K2 125 100 75 60 105 135 33 11 14 119 14,113 S32 SP2000-0076-5T-BA2K2 125 125 100 75 125 165 35 14.5 16 185 17,332 S32 SP2000-0088-5T-BA2K2 150 150 150 100 150 200 35 14.5 16 185 17,791 S32 SP2000-0131-5T-BA2K2 180 180 150 125 190 250 35 14.5 16 185 21,872 S32 SP2000-0164-5T-BA2K2 220 220 180 150 230 300 35 14.5 16 185 22,786 S42 SP2000-0181-5T-XIK0 300 300 250 220 305 380 38 20 16 299 24,956 S42 SP2000-0201-5T-XIK0 340 340 270 220 330 420 38 20 16 299 29,238 S42 SP2000-0218-5T-XIK0 400 410 300 270 360 465 38 20 16 299 32,805 S42 SP2000-0259-5T-XIK0 450 450 380 300 400 560 38 20 16 299 34,353 S52 SP2000-0290-5T-XIK0 480 485 400 340 450 600 38 23 16 353 49,944 S52 SP2000-0314-5T-XIK0 550 550 450 380 500 665 38 23 16 353 54,652 S52 SP2000-0368-5T-XIK0 610 610 485 430 560 720 38 23 16. 353 57,780 S52 SP2000-0401-5T-XIK0 770 610 550 480 640 850 38 23 16 353 67,608 *S65 SP2000-0457-5T-XIK0 860 770 680 550 720 880 55 39 22 970 102,504 *S65 SP2000-0524-5T-XIK0 970 860 770 610 800 960 55 39 22 970 112,152 *S65 SP2000-0598-5T-XIK0 1090 970 860 770 900 1100 55 39 22 970 117,458 *S65 SP2000-0748-5T-XIK0 1230 1230 970 860 1000 1300 55 39 22 970 123,030 *S70 SP2000-0831-5T-XIK0 1360 1360 1090 970 1200 1440 55 48 22 1213 143,414

* Input and Output reactor is required for these models. I-NOM: Continuous rated current of the inverter I-MAX: Maximum current produced by the inverter for 60 seconds every 10 minutes

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - SP2000 C - 27 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 SP2000 SINUS PENTA LIST PRICES SP2000 - SINUS PENTA 3 Year Warranty Flexible I/O Heat Sink Segregation Conformal Coating on all boards Effective 05-01-18 VOLTAGE: Full Metal Casing Supercedes All Previous 690V Wide Range of Communication Modules

690V 3-PHASE IP20/IP00

OVERLOAD CAPACITY DIMENSIONS FRAME (APPROX.) APPROX. LIST CATALOGUE NUMBER HP HP HP HP I-NOM I-MAX SIZE LIGHT STANDARD HEAVY STRONG WT. LBS PRICE 120% 140% 175% 200% HEIGHT WIDTH DEPTH S14 SP2000-0003-6T-BA2K2 7.5 5.5 5.5 4 7 8.5 21 11 10 41 4,397 S14 SP2000-0004-6T-BA2K2 10 7.5 5.5 5.5 9 11 21 11 10 41 4,493 S14 SP2000-0006-6T-BA2K2 12.5 10 10 7.5 11 13.5 21 11 10 41 4,590 S14 SP2000-0012-6T-BA2K2 15 12.5 10 10 13 16 21 11 10 41 4,686 S14 SP2000-0018-6T-BA2K2 20 15 15 12.5 17 21 21 11 10 41 4,783 S14 SP2000-0019-6T-BA2K2 25 20 15 15 21 25 21 11 10 41 5,265 S14 SP2000-0021-6T-BA2K2 30 25 20 15 25 30 21 11 10 41 5,544 S14 SP2000-0022-6T-BA2K2 40 30 30 25 33 40 21 11 10 41 5,855 S14 SP2000-0024-6T-BA2K2 50 40 30 30 40 48 21 11 10 41 5,991 S14 SP2000-0032-6T-BA2K2 60 50 50 40 52 63 21 11 10 41 6,901 S22 SP2000-0042-6T-BA2K2 75 60 50 40 60 72 33 11 14 119 10,815 S22 SP2000-0051-6T-BA2K2 100 75 75 60 80 96 33 11 14 119 11,510 S22 SP2000-0062-6T-BA2K2 100 100 75 75 85 110 33 11 14 119 13,198 S22 SP2000-0069-6T-BA2K2 125 125 100 75 105 135 33 11 14 119 14,113 S32 SP2000-0076-6T-BA2K2 150 150 125 100 125 165 35 14.5 16 185 17,332 S32 SP2000-0088-6T-BA2K2 180 180 150 125 150 200 35 14.5 16 185 17,791 S32 SP2000-0131-6T-BA2K2 220 220 220 150 190 250 35 14.5 16 185 21,872 S32 SP2000-0164-6T-BA2K2 300 270 250 180 230 300 35 14.5 16 185 22,786 S42 SP2000-0181-6T-XIK0 340 340 300 270 305 380 38 20 16 299 24,956 S42 SP2000-0201-6T-XIK0 430 430 340 300 330 420 38 20 16 299 29,238 S42 SP2000-0218-6T-XIK0 485 430 430 340 360 465 38 20 16 299 32,805 S42 SP2000-0259-6T-XIK0 550 550 485 430 400 560 38 20 16 299 34,353 S52 SP2000-0290-6T-XIK0 610 610 550 480 450 600 38 23 16 353 49,944 S52 SP2000-0314-6T-XIK0 680 610 610 510 500 665 38 23 16 353 54,652 S52 SP2000-0368-6T-XIK0 770 680 680 550 560 720 38 23 16 353 57,780 S52 SP2000-0401-6T-XIK0 860 860 770 680 640 850 38 23 16 353 88,787 *S65 SP2000-0457-6T-XIK0 970 860 770 680 720 880 55 39 22 970 102,504 *S65 SP2000-0524-6T-XIK0 1090 970 860 770 800 960 55 39 22 970 112,152 *S65 SP2000-0598-6T-XIK0 1230 1230 970 860 900 1100 55 39 22 970 117,458 *S65 SP2000-0748-6T-XIK0 1360 1360 1230 1090 1000 1300 55 39 22 970 123,030 *S70 SP2000-0831-6T-XIK0 1690 1500 1360 1230 1200 1440 55 48 22 1213 143,414

* Input and Output reactor is required for these models. I-NOM: Continuous rated current of the inverter I-MAX: Maximum current produced by the inverter for 60 seconds every 10 minutes

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - SP2000 C - 28 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 SP2000 SINUS PENTA PERIPHERALS LIST PRICES SP2000 - SINUS PENTA PERIPHERALS

Effective 05-01-18 Supercedes All Previous

SP2000 - SINUS PENTA PERIPHERALS CATALOGUE NUMBER DESCRIPTION LIST PRICE ZZ0101660 SINUS PENTA Keypad 199 ZZ0095700 SINUS PENTA remote keypad kit (includes 5m cable and door mounting) 135 ZZ0095699 SINUS PENTA remote keypad kit (includes 3m cable and door mounting) 120 ZZ0095210 KIT heatsink segregation for S05 Frame Size 131 ZZ0121920 KIT heatsink segregation for S12 Frame Size 144 ZZ0124930 KIT heatsink segregation for S14 Frame Size 225 ZZ0124931 KIT heatsink segregation for S22 Frame Size 375 ZZ0124932 KIT heatsink segregation for S32 Frame Size 375 ZZ0123901 KIT heatsink segregation for S41 Frame Size 330 ZZ0123902 KIT heatsink segregation for S42 Frame Size 330 ZZ0123903 KIT heatsink segregation for S51 Frame Size 330 ZZ0123904 KIT heatsink segregation for S52 Frame Size 330 SPCBS05 Conduit Box NEMA 1 for SINUS PENTA S05 190 SPCBS12 Conduit Box NEMA 1 for SINUS PENTA S12 190 SPCBS14 Conduit Box NEMA 1 for SINUS PENTA S14 210 SPCBS15 Conduit Box NEMA 1 for SINUS PENTA S15 210 SPCBS20 Conduit Box NEMA 1 for SINUS PENTA S20 210 SPCBS22 Conduit Box NEMA 1 for SINUS PENTA S22 270 SPCBS30 Conduit Box NEMA 1 for SINUS PENTA S30 270 SPCBS32 Conduit Box NEMA 1 for SINUS PENTA S32 300 SPCBS42 Conduit Box NEMA 1 for SINUS PENTA S41 & S42 400 SPCBS52 Conduit Box NEMA 1 for SINUS PENTA S52 600 ZZ0095834 Encoder card Multifunction ES836 for SINUS PENTA (Slot A) 181 ZZ0101830 ES860 SINcos card for SINUS PENTA (Slot A) 383 ZZ0101860 ES861 Resolver/Encoder card with Encoder repeated, (3) digital Input/Output (slot C) 741 ES847 (8) Digital Input, (6) Transistor Output, (4) PT100 Inputs up to 260ºC, (1) Analog Voltage Input, ZZ0101814 674 (1) Analog Current Input 0-20mA, (slot C) ZZ0101840 ES870 (8) Digital Input, (6) Output relays also for Multi-Pump Application (slot C) 344 ZZ4590010 SW Multipumps control SINUS PENTA N/C ZZ0101790 ES914 +24Vdc Supply for SINUS PENTA control 593 ZZ0095620 ES848 Supplier 100W -24Vdc -IP00, Input 300-800Vdc 393

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - SP2000 PERIPHERALS C - 29 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 SP2000 SINUS PENTA PERIPHERALS LIST PRICES SP2000 - SINUS PENTA PERIPHERALS

Effective 05-01-18 Supercedes All Previous

SP2000 - SINUS PENTA COMMUNICATION PERIPHERALS CATALOGUE NUMBER DESCRIPTION LIST PRICE PC1604662 Multi End Cable, Sinus Penta, D Connector to RS485 Three Wire (used with WW1420032) 243 WW1420032 USB to RS485 Terminals, (used with PC1604662) 440 SW300007J SW REMOTE DRIVE ES Ve. 2.30 + Instruction Manual 68 ES822 Insulated card RS232 and/or RS485 for SINUS PENTA (This Card Must Be Installed on ZZ0095850 132 the Inverter and It is Suggested for ModBBus Networks) (Slot B) ZZ0101820 ES851 Data Logger - RS-232 (Slot B) 778 ZZ4600013 KIT REMOTE DRIVE for PC (Cables, SW, USB/485 converter, instruction manual 484 KIT "ANY-BUS COMMUNICATOR" Converting card Modbus/Profibus DP/Device NET/canbus for ZZ4600030 2,494 32 drives connection, complete with cables & programming SW ZZ4600045 Profibus DP Card for SINUS PENTA (Kit Hardware and Software) (Slot B) 1,252 ZZ4600042 PROFIdrive Card for SINUS PENTA (Kit Hardware and Software) (Slot B) 1,784 ZZ4600055 Devicenet Card for SINUS PENTA (Kit Hardware and Software) (Slot B) 1,713 ZZ4600060 Interbus Card for SINUS PENTA (Kit Hardware and Software) (Slot B) 1,767 ZZ4600070 CANOpen Card for SINUS PENTA (Kit Hardware and Software) (Slot B) 1,814 ZZ4600080 ControlNet Card for SINUS PENTA (Kit Hardware and Software) (Slot B) 2,505 ZZ4600085 Lonworks Card for SINUS PENTA (Kit Hardware and Software) (Slot B) 2,031 ZZ4600100 Ethernet+IT Card for SINS PENTA (Kit Hardware and Software) (Slot B) 2,065 ZZ0102402 BacNet RS485 + ES919 (Slot B) 1,037 ZZ0102404 BacNet Ethernet + ES919 (Slot B) 1,037 ZZ0102406 Metasys N2 + ES919 (Slot B) 745 ZZR0988A0 120/240V Digital Input Card 1,750

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - SP2000 PERIPHERALS C - 30 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 VMX-SERIES FEATURES

MODEL: VMX-SERIES COMPACT SOFT STARTER DESCRIPTION: VMX Series Low Voltage Soft Starters; The control and Effective 05-01-18 protection you expect in an innovative soft starter design. Supercedes All Previous

APPLICATIONS • Pumps • Compressor • Conveyors • Chillers • Blowers • Fans

FEATURES • Standard Duty (500% O/L for 20 Sec) & Heavy Duty (500% O/L for 60 sec) Ratings Available • 9 to 1250A Current Ratings • Chassis Style or Configured Style Available • Multiple Ramps to Start Any Load • Built-In Deceleration Control, Dual ramp, Kick Start and Jog Modes • Start & Run Protection • Real Time Thermal Modelling • Phase Loss Protection • Electronic Shear Pin • Built-In Motor Protection • Short Circuit Protection • Phase Current Imbalance/Loss protection • Complete with Bypass Contactor • Pump Flex Deceleration • 3 programmable Output Contacts • Built in RS485 Communications • Fault History • Narrow width for MCC Mounting • Remote Keypad Mounting Option Available • Units operate on 230, 460 or 600 volts • 1 Year Warranty • UL, cUL and CE Approved

Control Products - VMX-SERIES C - 31 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 VMX-SERIES LIST PRICES VMX-SERIES LOW VOLTAGE SOFT-STARTER Current Ramp or Voltage Ramp, with Current Limit Complete with Decel Control, Dual Ramp, Kick Start and Jog Modes Integral up to Speed Bypass Contactor PTC Thermisor Input Effective 05-01-18 VOLTAGE: RS-485 Modbus - RTU Communications Supercedes All Previous 230V / 460V / 575V 120 Volts AC Control 24V DC Dry Contact Inputs, No External DC Power Supply Required Chassis Mount

ADJUSTABLE RANGE 230V / HP 460V / HP 575V / HP LIST CATALOGUE NUMBER (AMPS) HD SD HD SD HD SD PRICE VMX-18-BP 9-18 5 5 10 10 10 15 2,365 VMX-28-BP 14-28 7.5 7.5 15 20 20 25 2,365 VMX-39-BP 19-39 10 10 25 25 30 30 2,485 VMX-48-BP 24-48 15 15 30 30 30 40 2,485 VMX-62-BP 31-62 20 20 40 40 50 50 2,512 VMX-78-BP 39-78 25 25 50 60 60 60 2,615 VMX-92-BP 46-92 30 30 60 60 75 75 3,102 VMX-112-BP 56-112 30 40 75 75 75 100 3,417 VMX-150-BP 75-150 50 50 100 100 75 125 4,500 VMX-160-BP 80-160 50 60 100 125 75 150 4,812 VMX-210-BP 105-210 60 75 150 150 150 200 6,945 VMX-275-BP 138-275 75 100 150 200 150 200 8,247 VMX-361-BP 181-361 125 125 250 300 300 350 8,900 VMX-450-BP 225-450 150 150 300 350 300 450 9,985 VMX-550-BP 275-550 200 200 400 450 500 500 12,607 VMX-600-BP 300-600 200 200 450 500 600 600 12,835 VMX-862-BP 431-862 300 300 500 600 600 700 18,252 VMX-900-BP 450-900 300 350 600 700 600 900 20,160

SD - Standard Duty 500% - 20 seconds 1.0 S.F. with shunt rated bypass HD - Heavy Duty 500% - 60 seconds 1.15 S.F. with fully rated bypass

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted. (3) Model VMX-210-BP and above utilize an external by-pass contactor (included with softstarter)

DIMENSIONS AND SHIPPING WEIGHTS CATALOGUE NUMBER HEIGHT INCHES (mm) WIDTH INCHES (mm) DEPTH INCHES (mm) APPROX. WT. LBS (kg) VMX-18-BP thru VMX-48-BP 8.85 (225) 13 (5.9) VMX-62-BP thru VMX-112-BP 14 (355.6) 8 (203) 6.65 (169) 23 (10.4) VMX-150-BP thru VMX-160-BP 19 (482.6) 33 (15) VMX-210-BP 130 (59) 28.1 (713.7) VMX-275-BP 140 (63.5) 12.5 (317.5) 9.1 (231) VMX-361-BP thru VMX-450-BP 29.3 (744.2) 145 (65.8) VMX-550-BP thru VMX-600-BP 29.5 (749.3) 165 (74.8) VMX-862-BP thru VMX-900-BP 44.25 (1124) 11.86 (301.3) 325 (147) 25.5 (647.7) VMX-1006-BP thru VMX-1250-BP 50.77 (1289.6) 13.28 (337.3) 400 (181)

Control Products - VMX-SERIES C - 32 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 VMX-STARTERS LIST PRICES VMX STARTERS COMPLETE IN NEMA 1 AND NEMA 12 Panel does not include Control Transformer (120Vac Must be fed Externally). List pricing includes the VMX and the enclosure. Items on this page are not stocked in TECO-Westinghouse warehouses, however, are available for quick shipment from the factory. Effective 05-01-18 VOLTAGE: Please contact your TWMI representative for availability. Supercedes All Previous 230V / 460V / 575V To choose the model number refer to page C-35.

NEMA 1 ENCLOSURE NEMA 12 ENCLOSURE

CATALOGUE DIMENSIONS CATALOGUE DIMENSIONS LIST PRICE LIST PRICE NUMBER HEIGHT WIDTH DEPTH NUMBER HEIGHT WIDTH DEPTH VMX-18-BP-N 15 10 8 2,745 VMX-18-BP-E 24 16 8 3,790 VMX-28-BP-N 15 10 8 2,745 VMX-28-BP-E 24 16 8 3,790 VMX-39-BP-N 15 10 8 2,865 VMX-39-BP-E 24 16 8 3,910 VMX-48-BP-N 15 10 8 2,865 VMX-48-BP-E 24 16 8 3,910 VMX-62-BP-N 20 10 8 3,115 VMX-62-BP-E 24 16 8 3,937 VMX-78-BP-N 20 10 8 3,220 VMX-78-BP-E 24 16 8 4,040 VMX-92-BP-N 20 10 8 3,705 VMX-92-BP-E 24 16 8 4,527 VMX-112-BP-N 20 10 8 4,022 VMX-112-BP-E 24 16 8 4,845 VMX-150-BP-N 28 10 8 5,255 VMX-150-BP-E 36 24 8 6,007 VMX-160-BP-N 28 10 8 5,567 VMX-160-BP-E 36 24 8 6,317 VMX-210-BP-N 48 24 12 7,942 VMX-210-BP-E 48 24 12 8,842 VMX-275-BP-N 48 24 12 9,260 VMX-275-BP-E 48 24 12 10,145 VMX-361-BP-N 48 24 12 9,920 VMX-361-BP-E 48 24 12 10,797 VMX-450-BP-N 60 24 12 11,160 VMX-450-BP-E 60 24 12 12,180 VMX-550-BP-N 60 24 12 13,816 VMX-550-BP-E 60 24 12 14,802 VMX-600-BP-N 60 24 12 14,045 VMX-600-BP-E 60 24 12 15,030

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

CABLE ASSEMBLY FOR REMOTE MOUNTING KEYPAD CATALOGUE NUMBER DESCRIPTION CABLE LENGTH APPLICABLE MODEL LIST PRICE VMX-KP12-KIT2-1 Remote Display Kit 1m Cable VMX-18 to VMX-48 400 VMX-KP12-KIT2-2 Remote Display Kit 2m Cable VMX-18 to VMX-48 410 VMX-KP12-KIT2-3 Remote Display Kit 3m Cable VMX-18 to VMX-48 420 VMX-KP12-KIT-1 Remote Display Kit 1m Cable VMX-62 and Above 400 VMX-KP12-KIT-2 Remote Display Kit 2m Cable VMX-62 and Above 410 VMX-KP12-KIT-3 Remote Display Kit 3m Cable VMX-62 and Above 420

Control Products - VMX-SERIES ENCLOSURES C - 33 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 VMX-SERIES CONFIGURED FEATURES MODEL: VMX-SERIES COMPACT SOFT STARTER - CONFIGURED Effective 05-01-18 DESCRIPTION: VMX Series Low Voltage Soft Starters; The control and Supercedes All Previous protection you expect in an innovative soft starter design.

APPLICATIONS • Pumps • Compressor • Conveyors • Chillers • Blowers • Fans

FEATURES • Standard Duty (500% O/L for 20 Sec) & Heavy Duty (500% O/L for 60 Sec) Ratings Available • 9 to 1250A Current Ratings • Multiple Ramps to Start Any Load • Built-In Deceleration Control, Dual ramp, Kick Start and Jog Modes • Start & Run Protection • Real Time Thermal Modelling • Phase Loss Protection • Electronic Shear Pin • Motor Duty Cycle Protection • Short Circuit Protection • Phase Current Imbalance/Loss protection • Built in Circuit Breaker • Nema 4/12 Enclosure • Advanced Motor Protection • Control Transformer Included • Door Mounted Keypad and Pilot Devices:

- Digital Keypad - Power On Pilot Light - Start/Stop Button - Start Fault Pilot Light - Local / Off / Remote Switch - E-Stop Fault Pilot Light - Motor Run Pilot Light - External Interlock Pilot Light • 1 Year Warranty • UL, cUL and CE Approved

Control Products - VMX-SERIES CONFIGURED C - 34 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 HEAVY DUTY VMX-SERIES CONFIGURED LIST PRICES VMX - SERIES LOW VOLTAGE SOFT-STARTER NEMA 4/12 CONFIGURED SOFT-STARTERS - HEAVY DUTY WITH CIRCUIT BREAKER Standard VMX Series Features HD - Heavy Duty 500% - 60 Seconds 1.15 S.F. with Line Rated Bypass Effective 05-01-18 VOLTAGE: Built-In Disconnect with Door-Mounted Lockable Operator Handle Supercedes All Previous 230V / 460V / 575V NEMA 4/12 Enclosure Integral Line-Start (ATL) Rated Bypass Contactor - D.O.L. Rated Advanced Motor Protection LINE AND CONTROL VOLTAGES: Control Power Transformer 1 = 208V, 120V Ctrl, 50/60Hz Door Mounted Keypad and Pilot Devices: 2 = 230V, 120V Ctrl, 50/60Hz - Digital Keypad - Power On Pilot Light 3 = 380V, 220V Ctrl, 50/60Hz - Start/Stop Button - Start Fault Pilot Light 4 = 460V, 120V Ctrl, 50/60Hz - Local / Off / Remote Switch - E-Stop Fault Pilot Light 5 = 575V, 120V Ctrl, 50/60Hz - Motor Run Pilot Light - External Interlock Pilot Light 6 = 415V, 220V Ctrl, 50/60Hz 7 = 220V, 220V Ctrl, 50/60Hz

MAXIMUM AMP NOMINAL MOTOR HP RATING LIST CATALOGUE NUMBER RATING 208V 230V 460V 575V PRICE VMX-H-21-FS* 21 7.5 7.5 15 15 8,520 VMX-H-27-FS* 27 10 10 25 20 8,725 VMX-H-40-FS* 40 10 15 30 25 8,830 VMX-H-45-CB* 45 15 20 40 30 9,350 VMX-H-55-CB* 55 20 25 50 40 9,870 VMX-H-68-CB* 68 25 30 60 50 10,175 VMX-H-96-CB* 96 30 30 75 60 12,055 VMX-H-125-CB* 125 40 50 100 75 12,735 VMX-H-156-BP* 156 60 60 150 100 14,750 VMX-H-220-CB* 220 60 75 150 150 18,205 VMX-H-248-CB* 248 100 125 250 200 19,365 VMX-H-400-CB* 400 125 150 300 300 23,815 VMX-H-480-CB* 480 150 200 400 500 32,305 VMX-H-600-CB* 600 200 200 500 600 39,675

* Specify line and control voltage.

VMX CONFIGURED STARTER OPTIONS CATALOGUE NUMBER DESCRIPTION LIST PRICE Option AA Dual ramp option, includes 2-position switch 193 Option B Jog option, includes run/jog switch 241 Option H Enclosure heater with thermostat 802 Option SA Surge suppressor 802 Option OL Additional overload relay for backup in X-line mode 481 Option RX RX Series motor protection/metering relay (door mounted) 1,043

NOTE: (1) Items on this page are not stocked in TECO-Westinghouse warehouses, however, are available for quick shipment from the factory. Please contact your TWMI representative for availability. (2) Prices subject to change without notice. (3) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - VMX-SERIES HEAVY DUTY CONFIGURED C - 35 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 STANDARD DUTY VMX-SERIES CONFIGURED LIST PRICES VMX - SERIES LOW VOLTAGE SOFT-STARTER NEMA 4/12 CONFIGURED SOFT-STARTERS - STANDARD DUTY WITH CIRCUIT BREAKER Standard VMX Series Features SD - Standard Duty 500% - 20 Seconds 1.00 S.F. with a Shunt Rated Bypass Effective 05-01-18 VOLTAGE: Built-In Disconnect with Door-Mounted Lockable Operator Handle Supercedes All Previous 230V / 460V / 575V NEMA 4/12 Enclosure Advanced Motor Protection Control Power Transformer LINE AND CONTROL VOLTAGES: Door Mounted Keypad and Pilot Devices: 1 = 208V, 120V Ctrl, 50/60Hz - Digital Keypad - Power On Pilot Light 2 = 230V, 120V Ctrl, 50/60Hz - Start/Stop Button - Start Fault Pilot Light 3 = 380V, 220V Ctrl, 50/60Hz - Local / Off / Remote Switch - E-Stop Fault Pilot Light 4 = 460V, 120V Ctrl, 50/60Hz - Motor Run Pilot Light - External Interlock Pilot Light 5 = 575V, 120V Ctrl, 50/60Hz 6 = 415V, 220V Ctrl, 50/60Hz 7 = 220V, 220V Ctrl, 50/60Hz

MAXIMUM AMP NOMINAL MOTOR HP RATING LIST CATALOGUE NUMBER RATING 208V 230V 460V 575V PRICE VMX-S-18-FS* 18 5 5 10 15 7,420 VMX-S-28-FS* 28 7.5 7.5 20 25 7,420 VMX-S-39-FS* 39 10 10 25 30 7,550 VMX-S-48-FS* 48 10 15 30 40 7,600 VMX-S-62-CB* 62 15 20 40 60 7,630 VMX-S-78-CB* 78 20 25 50 75 8,935 VMX-S-92-CB* 92 25 30 60 75 9,970 VMX-S-112-CB* 112 30 40 75 100 11,010 VMX-S-150-CB* 150 40 50 100 125 12,260 VMX-S-160-CB* 160 50 60 125 150 13,295 VMX-S-210-CB* 210 60 75 150 200 14,960 VMX-S-275-CB* 275 75 100 200 250 17,555 VMX-S-305-CB* 305 100 125 250 300 18,905 VMX-S-361-CB* 361 125 125 300 350 20,150 VMX-S-450-CB* 450 150 150 350 400 20,735 VMX-S-550-CB* 550 150 200 450 500 33,030 VMX-S-600-CB* 600 200 200 500 600 38,120 VMX-S-862-CB* 862 250 300 600 700 42,065

* Specify line and control voltage.

VMX CONFIGURED STARTER OPTIONS CATALOGUE NUMBER DESCRIPTION LIST PRICE Option AA Dual ramp option, includes 2-position switch 193 Option B Jog option, includes run/jog switch 241 Option H Enclosure heater with thermostat 802 Option SA Surge suppressor 802 Option OL Additional overload relay for backup in X-line mode 481 Option RX RX Series motor protection/metering relay (door mounted) 1,043

NOTE: (1) Items on this page are not stocked in TECO-Westinghouse warehouses, however, are available for quick shipment from the factory. Please contact your TWMI representative for availability. (2) Prices subject to change without notice. (3) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - VMX-SERIES STANDARD DUTY CONFIGURED C - 36 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 MVC-PLUS FEATURES

MODEL: MVC-PLUS MEDIUM VOLTAGE SOFT-STARTER DESCRIPTION: Advanced Motor Control Protection and Monitoring in a Effective 05-01-18 Reliable Field Proven Soft Starter. Supercedes All Previous

APPLICATIONS • Pump Systems • Gas Compression • Conveyor Systems • No Load Motor Test Stands • Aggregate Crushers • ID Fans & Blowers

FEATURES • Available Voltage Class: 2300V, 3300V, 4160V, 6000/7200V, 11kV-15kV • Units Available Up to 10,000 HP at 7.2kV (1500 amps) • Units Available Up to 20,000 HP at 15kV (800 amps) • 2,300V-7,200V (60kV BIL) / 11,000-15,000V (110kV BIL) • Programmable Keypad/Operator with 2 Lines x 20 Character w, Backlit Display • Up to 12 RTD Inputs Available • Rugged Full Pulse Gate Firing Circuit • Custom Packaged Systems Available Including Cascading • Low Voltage Optically Isolated from Medium Voltage • 500% current limit for 60 seconds • Fully Rated Disconnect Switch • Voltage Ramps with Current Limit • Pump-Flex Feature Controls Water Hammer • Built in RS-485 Communication • Other Communication Protocols Available • Free Software for Start up and Monitoring • DV/DT Transient Voltage Protection • Fully rated Line and Bypass Contactor • Digital Control Unit on the Low Voltage Door • Volts, Amps and Power reading for Measurement and Protection • Motor and Starter Protection:

- Phase Imbalance - Phase Reversal - Short Circuit Detection - Over / Under Current - Over / Under Voltage - Shorted SCR - Starter Over-Temp - Coast Down Lockout - Starts Per Hour Lockout - Time Between Starts

• NEMA 12 Enclosure Standard (3R Enclosure Optional) • 3 Year Warranty with Factory Start-Up • UL, cUL and CE Approved

Control Products - MVC-PLUS C - 37 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 MVC-PLUS LIST PRICES MVC-PLUS MEDIUM VOLTAGE SOFT-STARTER Load-break Disconnect Switch with Door Safety Interlock Main Isolation Vacuum Contactor Fully Rated Bypass Contactor Heavy Duty SCR Stacks with Ring Transformer Isolation Effective 05-01-18 VOLTAGE: Fiber Optically Isolated Low Voltage Compartment Supercedes All Previous 2300V / 4160V / 8 Programmable Relay Outputs for Control Flexibility 2 Programmable Analog Outputs (0-10vdc or 4-20ma) 6600V / 11000V / RS-485 Communications (Modbus RTU) 13800V NEMA 12 Gasketed Enclosure

2300V CATALOGUE NUMBER MAX AMPS HP LIST PRICE MVC4-23100-E-SWG 100 350 61,347 MVC4-23200-E-SWG 200 700 61,630 MVC4-23400-E-SWG 400 1400 62,215 MVC4-23600-E-SWG 630 2700 105,500

4160V CATALOGUE NUMBER MAX AMPS HP LIST PRICE MVC4-41100-E-SWG 100 600 76,447 MVC4-41200-E-SWG 200 1250 78,260 MVC4-41400-E-SWG 400 2500 85,207 MVC4-41600-E-SWG 630 4000 167,300 MVC4-411000-E-SWG 1000 7200 406,100

6600V CATALOGUE NUMBER MAX AMPS HP LIST PRICE MVC4-66100-E-SWG 100 1000 76,070 MVC4-66200-E-SWG 200 2000 98,930 MVC4-66400-E-SWG 400 4000 106,367 MVC4-66600-E-SWG 630 7400 190,700

11000V CATALOGUE NUMBER MAX AMPS HP LIST PRICE MVC4-110200-E-SWG 200 3400 398,300 MVC4-110400-E-SWG 400 6700 430,255 MVC4-110600-E-SWG 630 10,600 561,200

13800V CATALOGUE NUMBER MAX AMPS HP LIST PRICE MVC4-138100-E-SWG 100 2100 430,255 MVC4-138200-E-SWG 200 4200 466,700 MVC4-138400-E-SWG 400 8500 527,400 MVC4-138600-E-SWG 600 12500 813,400 MVC4-1381000-E-SWG 1000 21000 1,137,900

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted. (3) Size units based on motor amps including service factor.

Control Products - MVC-PLUS C - 38 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 MV SOFT STARTER DIMENSIONS LIST PRICES MV SOFT STARTER DIMENSIONS

Effective 05-01-18 Supercedes All Previous

DIMENSIONS VOLTAGE CATALOGUE NUMBER HEIGHT WIDTH DEPTH MVC4-23100-E-SWG MVC4-23200-E-SWG 92 36 30 2300 MVC4-23400-E-SWG MVC4-23600-E-SWG 93 81 44 MVC4-41100-E-SWG MVC4-41200-E-SWG 92 36 30 4160 MVC4-41400-E-SWG MVC4-41600-E-SWG 92 72 30 MVC4-411000-E-SWG 92 81 44 MVC4-66100-E-SWG MVC4-66200-E-SWG 92 42 30 6600 MVC4-66400-E-SWG MVC4-66600-E-SWG 92 117 30 MVC4-110200-E-SWG 11000V MVC4-110400-E-SWG 95 126 44 MVC4-110600-E-SWG MVC4-138100-E-SWG MVC4-138200-E-SWG 95 126 44 13800V MVC4-138400-E-SWG MVC4-138600-E-SWG 95 120 80 MVC4-1381000-E-SWG MV - ACROSS THE LINE STARTER MEDIUM VOLTAGE ACROSS THE LINE STARTER DIMENSIONS CATALOGUE NUMBER VOLTAGE AMPS HP LIST PRICE HEIGHT WIDTH DEPTH MVC4-23200-E-DOL 200 700 39,072 92 36 30 MVC4-23400-E-DOL 2300 400 1400 42,470 MVC4-23600-E-DOL 600 2100 92 72 30 76,447

MEDIUM VOLTAGE ACROSS THE LINE STARTER DIMENSIONS CATALOGUE NUMBER VOLTAGE AMPS HP LIST PRICE HEIGHT WIDTH DEPTH MVC4-41200-E-DOL 200 1250 49,265 92 36 30 MVC4-41400-E-DOL 4160 400 2500 56,062 MVC4-41600-E-DOL 600 3800 92 72 30 98,532

NOTE: (1) Max Amperage must be lower than Motor Full load current x Motor Service Factor. (2) Motor Current and Service Factor must be supplied on order for Fuse and CT selection. (3) Estimate assumes motor power factor = 0.8 or better, Motor Efficiency is 0.95 or better and S.F. = 1.15. (4) Prices subject to change without notice. (5) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - MV - ACROSS THE LINE STARTERS C - 39 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 MTE REACTORS FEATURES

MODEL: MTE REACTORS DESCRIPTION: RL Line/Load Reactors Solve Line and Load Power Effective 05-01-18 Quality Problems Supercedes All Previous

APPLICATIONS • Harmonic Compensation • Output of Drive System • Input of Drive System

FEATURES • 1 to 1,500 Amp Current range • 208V to 690V, 50/60Hz, 3-Phase • Available for use on Single Phase Input • Epoxy Impregnated • High Saturation Current Rating • For use on VFD Systems with Switching Frequencies up to 20kHz • 150% O/L Rated • Protects Motors from Long lead Lengths • Reduce Output Voltage dV/dT • Virtually Eliminate Nuisance Tripping • Extended Semiconductor Life • Transient Protection Options Available • Reduce Motor Temperature • Reduce Motor Audible Noise • Available in Chassis Style, NEMA 1 and NEMA 3R • UL, cUL, CSA and CE Approved

Control Products - MTE REACTORS C - 40 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 208V-3% MTE REACTORS LIST PRICES LINE & LOAD REACTORS: CHASSIS 3-PHASE

Effective 05-01-18 VOLTAGE: Supercedes All Previous 208V-3%

208V 3-PHASE 3% IMPEDANCE OPTIONAL

HP DIMENSIONS (APPROX.) APPROX. WT. LIST NEMA 1 LIST CATALOGUE NUMBER AMPS RATING HEIGHT WIDTH DEPTH LBS PRICE ENCLOSURE PRICE RL-00802 1 8 4.8 6 3 8 217 CAB-8 158 RL-00801 1.5 8 4.8 6 3 7 193 CAB-8 158 RL-01201 2 12 5 6 3.3 9 228 CAB-8 158 RL-01801 3 18 5.3 6 3.2 9 298 CAB-8 158 RL-02501 5 25 5.8 7.2 3.5 11 312 CAB-13V 210 RL-03501 7.5 35 5.8 7.2 4 14 352 CAB-13V 210 RL-04501 10 45 7.4 9 4.7 23 463 CAB-13V 210 RL-05501 15 55 7.3 9 5.3 24 587 CAB-13V 210 RL-08001 20 80 7.2 9 6.3 25 598 CAB-13V 210 RL-10001 25 100 7.3 9 6.5 29 766 CAB-13V 210 RL-13001 30 130 7 9 4.66 29 848 CAB-13V 210 RL-13001 40 130 7 9 4.66 29 848 CAB-13V 210 RL-16001 50 160 7.2 9 6.8 41 1,078 CAB-13V 210 RL-20001B14 60 200 7.5 9 7.3 38 1,135 CAB-13V 210 RL-25001B14 75 250 7.5 9 9 47 1,455 CAB-13V 210 RL-32001B14 100 320 9 10.8 8.3 80 2,141 CAB-17V 569 RL-50001B14 125 500 9 10.8 10.5 93 2,364 CAB-17V 569 RL-50001B14 150 500 9 10.8 10.5 93 2,364 CAB-17V 569 RL-60001 200 600 11.5 14.4 10 120 3,776 CAB-26C 1,673 RL-75001 250 750 11.5 14.4 11 140 4,842 CAB-26C 1,673

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - 208V-3% MTE REACTORS C - 41 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 208V-5% MTE REACTORS LIST PRICES LINE & LOAD REACTORS: CHASSIS 3-PHASE

Effective 05-01-18 VOLTAGE: Supercedes All Previous 208V-5%

208V 3-PHASE 5% IMPEDANCE OPTIONAL

HP DIMENSIONS (APPROX.) APPROX. WT. LIST NEMA 1 LIST CATALOGUE NUMBER AMPS RATING HEIGHT WIDTH DEPTH LBS PRICE ENCLOSURE PRICE RL-00802 1 8 4.8 6 3 8 217 CAB-8 158 RL-00802 1.5 8 4.8 6 3 8 217 CAB-8 158 RL-01202 2 12 5 6 3.3 10 242 CAB-8 158 RL-01802 3 18 5.3 6 3.5 12 305 CAB-8 158 RL-02502 5 25 5.8 7.2 3.5 14 352 CAB-13V 210 RL-03502 7.5 35 5.8 7.2 4 16 370 CAB-13V 210 RL-05502 10 55 7 9 5.3 27 640 CAB-13V 210 RL-08002 15 80 7.2 9 6.5 33 853 CAB-13V 210 RL-10002 20 100 7.3 9 6.8 37 841 CAB-13V 210 RL-08001 25 80 7.2 9 6.3 25 598 CAB-13V 210 RL-10001 30 100 7.3 9 6.5 29 766 CAB-13V 210 RL-13001 40 130 7 9 4.66 29 848 CAB-13V 210 RL-16001 50 160 7.2 9 6.8 41 1,078 CAB-13V 210 RL-20002B14 60 200 7.5 9 8.3 54 1,668 CAB-13V 210 RL-25002B14 75 250 8.5 10.8 9 80 2,120 CAB-17V 569 RL-32001B14 100 320 9 10.8 8.3 80 2,141 CAB-17V 569 RL-50002 125 500 11.5 14.4 11.5 118 4,379 CAB-26C 569 RL-60002 150 600 11.25 14.4 12 175 4,894 CAB-26C 1,673 RL-60001 200 600 11.5 14.4 10 120 3,776 CAB-26C 1,673 RL-75002 250 750 11.5 14.4 12.5 190 6,100 CAB-26C 1,673

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - 208V-5% MTE REACTORS C - 42 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 240V-3% MTE REACTORS LIST PRICES LINE & LOAD REACTORS: CHASSIS 3-PHASE

Effective 05-01-18 VOLTAGE: Supercedes All Previous 240V-3%

240V 3-PHASE 3% IMPEDANCE OPTIONAL

HP DIMENSIONS (APPROX.) APPROX. WT. LIST NEMA 1 LIST CATALOGUE NUMBER AMPS RATING HEIGHT WIDTH DEPTH LBS PRICE ENCLOSURE PRICE RL-00401 1 4 4.1 4.4 2.8 4 184 CAB-8 158 RL-00801 1.5 8 4.8 6 3 7 193 CAB-8 158 RL-00801 2 8 4.8 6 3 7 193 CAB-8 158 RL-01201 3 12 5 6 3.3 9 228 CAB-8 158 RL-01801 5 18 5.3 6 3.2 9 298 CAB-8 158 RL-02501 7.5 25 5.8 7.2 3.5 11 312 CAB-13V 210 RL-03501 10 35 5.8 7.2 4 14 352 CAB-13V 210 RL-04501 15 45 7.4 9 4.7 23 463 CAB-13V 210 RL-08001 20 80 7.2 9 6.3 25 598 CAB-13V 210 RL-10001 25 100 7.3 9 6.5 29 766 CAB-13V 210 RL-10001 30 100 7.3 9 6.5 29 766 CAB-13V 210 RL-13001 40 130 7 9 4.66 29 848 CAB-13V 210 RL-13001 50 130 7 9 4.66 29 848 CAB-13V 210 RL-16001 60 160 7.2 9 6.8 41 1,078 CAB-13V 210 RL-20001B14 75 200 7.5 9 7.3 38 1,135 CAB-13V 210 RL-25001B14 100 250 7.5 9 9 47 1,455 CAB-13V 210 RL-32001B14 125 320 9 10.8 8.3 80 2,141 CAB-17V 569 RL-40001B14 150 400 10 10.8 10 84 2,357 CAB-17V 569 RL-50001B14 200 500 9 10.8 10.5 93 2,364 CAB-17V 569 RL-60001 250 600 11.5 14.4 10 120 3,776 CAB-26C 1,673

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - 240V-3% MTE REACTORS C - 43 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 240V-5% MTE REACTORS LIST PRICES LINE & LOAD REACTORS: CHASSIS 3-PHASE

Effective 05-01-18 VOLTAGE: Supercedes All Previous 240V-5%

240V 3-PHASE 5% IMPEDANCE OPTIONAL

HP DIMENSIONS (APPROX.) APPROX. WT. LIST NEMA 1 LIST CATALOGUE NUMBER AMPS RATING HEIGHT WIDTH DEPTH LBS PRICE ENCLOSURE PRICE RL-00803 1 8 4.8 6 3.4 11 263 CAB-8 158 RL-00802 1.5 8 4.8 6 3 8 217 CAB-8 158 RL-00802 2 8 4.8 6 3 8 217 CAB-8 158 RL-01202 3 12 5 6 3.3 10 242 CAB-8 158 RL-01802 5 18 5.3 6 3.5 12 305 CAB-8 158 RL-03502 7.5 35 5.8 7.2 4 16 370 CAB-13V 210 RL-03502 10 35 5.8 7.2 4 16 370 CAB-13V 210 RL-05502 15 55 7 9 5.3 27 640 CAB-13V 210 RL-08002 20 80 7.2 9 6.5 33 853 CAB-13V 210 RL-10002 25 100 7.3 9 6.8 37 841 CAB-13V 210 RL-10002 30 100 7.3 9 6.8 37 841 CAB-13V 210 RL-13002 40 130 7.2 9 6.8 43 1,116 CAB-13V 210 RL-13001 50 130 7 9 4.66 29 848 CAB-13V 210 RL-16002 60 160 8.3 10.8 6 50 1,602 CAB-13V 210 RL-20002B14 75 200 7.5 9 8.3 54 1,668 CAB-13V 210 RL-25002B14 100 250 8.5 10.8 9 80 2,120 CAB-17V 569 RL-32002B14 125 320 9 10.8 10 102 2,449 CAB-17V 569 RL-40002B14 150 400 11.25 15 11.5 118 3,932 CAB-17V 569 RL-50002 200 500 11.5 14.4 11.5 118 4,379 CAB-26C 1,673 RL-60002 250 600 11.25 14.4 12 175 4,894 CAB-26C 1,673

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - 240V-5% MTE REACTORS C - 44 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 480V-3% MTE REACTORS LIST PRICES LINE & LOAD REACTORS: CHASSIS 3-PHASE

Effective 05-01-18 VOLTAGE: Supercedes All Previous 480V-3%

480V 3-PHASE 3% IMPEDANCE OPTIONAL

HP DIMENSIONS (APPROX.) APPROX. WT. LIST NEMA 1 LIST CATALOGUE NUMBER AMPS RATING HEIGHT WIDTH DEPTH LBS PRICE ENCLOSURE PRICE RL-00201 1 2 4.1 4.4 2.8 4 182 CAB-8 158 RL-00402 1.5 4 4.1 4.4 2.8 4 189 CAB-8 158 RL-00402 2 4 4.1 4.4 2.8 4 189 CAB-8 158 RL-00803 3 8 4.8 6 3.4 11 263 CAB-8 158 RL-00802 5 8 4.8 6 3 8 217 CAB-8 158 RL-01202 7.5 12 5 6 3.3 10 242 CAB-8 158 RL-01802 10 18 5.3 6 3.5 12 305 CAB-8 158 RL-02502 15 25 5.8 7.2 3.5 14 352 CAB-13V 210 RL-03502 20 35 5.8 7.2 4 16 370 CAB-13V 210 RL-03502 25 35 5.8 7.2 4 16 370 CAB-13V 210 RL-04502 30 45 7.4 9 4.7 28 555 CAB-13V 210 RL-05502 40 55 7 9 5.3 27 640 CAB-13V 210 RL-08002 50 80 7.2 9 6.5 33 853 CAB-13V 210 RL-08002 60 80 7.2 9 6.5 33 853 CAB-13V 210 RL-10002 75 100 7.3 9 6.8 37 841 CAB-13V 210 RL-13002 100 130 7.2 9 6.8 43 1,116 CAB-13V 210 RL-16002 125 160 8.3 10.8 6 50 1,602 CAB-13V 210 RL-20002B14 150 200 7.5 9 8.3 54 1,668 CAB-13V 210 RL-25002B14 200 250 8.5 10.8 9 80 2,120 CAB-17V 569 RL-32002B14 250 320 9 10.8 10 102 2,449 CAB-17V 569 RL-40002B14 300 400 11.25 15 11.5 118 3,932 CAB-17V 569 RL-50002 350 500 11.5 14.4 11.5 118 4,379 CAB-26C 1,673 RL-50002 400 500 11.5 14.4 11.5 118 4,379 CAB-26C 1,673 RL-60002 500 600 11.25 14.4 12 175 4,894 CAB-26C 1,673 RL-75002 600 750 11.5 14.4 12.5 190 6,100 CAB-26C 1,673

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - 480V-3% MTE REACTORS C - 45 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 480V-5% MTE REACTORS LIST PRICES LINE & LOAD REACTORS: CHASSIS 3-PHASE

Effective 05-01-18 VOLTAGE: Supercedes All Previous 480V-5%

480V 3-PHASE 5% IMPEDANCE OPTIONAL

HP DIMENSIONS (APPROX.) APPROX. WT. LIST NEMA 1 LIST CATALOGUE NUMBER AMPS RATING HEIGHT WIDTH DEPTH LBS PRICE ENCLOSURE PRICE RL-00202 1 2 4.1 4.4 2.8 4 191 CAB-8 158 RL-00404 1.5 4 4.1 4.4 3.4 6 226 CAB-8 158 RL-00404 2 4 4.1 4.4 3.4 6 226 CAB-8 158 RL-00804 3 8 4.8 6 3.4 13 303 CAB-8 158 RL-00803 5 8 4.8 6 3.4 11 263 CAB-8 158 RL-01203 7.5 12 5 6 3.9 18 347 CAB-8 158 RL-01803 10 18 6.1 8.1 4 16 403 CAB-13V 210 RL-02503 15 25 5.8 7.2 4.3 20 459 CAB-13V 210 RL-03503 20 35 7.4 9 4.7 30 562 CAB-13V 210 RL-03503 25 35 7.4 9 4.7 30 562 CAB-13V 210 RL-04503 30 45 7.3 9 5.3 39 710 CAB-13V 210 RL-05503 40 55 7 9 6 41 845 CAB-13V 210 RL-08003 50 80 8.5 10.8 6.8 61 1,489 CAB-13V 210 RL-08003 60 80 8.5 10.8 6.8 61 1,489 CAB-13V 210 RL-10003 75 100 8.25 10.8 6.16 74 1,684 CAB-13V 210 RL-13003 100 130 8.5 11 6.16 64 1,696 CAB-13V 210 RL-16003 125 160 8.5 11.5 9 67 1,875 CAB-13V 210 RL-20003B14 150 200 8.3 10.8 10 100 2,448 CAB-13V 210 RL-25003B14 200 250 11.2 14.4 10.3 125 3,815 CAB-17V 569 RL-32003B14 250 320 11.25 14.4 10.5 160 4,121 CAB-17V 569 RL-40003B14 300 400 11.25 14.4 12.5 149 4,563 CAB-17V 569 RL-50003 350 500 11.5 14.4 13.3 210 5,190 CAB-26C 1,673 RL-50003 400 500 11.5 14.4 13.3 210 5,190 CAB-26C 1,673 RL-60003 500 600 11.25 14.4 15 270 6,608 CAB-26C 1,673 RL-75003 600 750 14.5 14.4 14 265 8,530 CAB-26C 1,673

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - 480V-5% MTE REACTORS C - 46 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 600V-3% MTE REACTORS LIST PRICES LINE & LOAD REACTORS: CHASSIS 3-PHASE

Effective 05-01-18 VOLTAGE: Supercedes All Previous 600V-3%

600V 3-PHASE 3% IMPEDANCE OPTIONAL

HP DIMENSIONS (APPROX.) APPROX. WT. LIST NEMA 1 LIST CATALOGUE NUMBER AMPS RATING HEIGHT WIDTH DEPTH LBS PRICE ENCLOSURE PRICE RL-00202 1 2 4.1 4.4 2.8 4 191 CAB-8 158 RL-00201 1.5 2 4.1 4.4 2.8 4 182 CAB-8 158 RL-00403 2 4 4.1 4.4 3.4 5 198 CAB-8 158 RL-00402 3 4 4.1 4.4 2.8 4 189 CAB-8 158 RL-00803 5 8 4.8 6 3.4 11 263 CAB-8 158 RL-01202 7.5 12 5 6 3.3 10 242 CAB-8 158 RL-01202 10 12 5 6 3.3 10 242 CAB-8 158 RL-01802 15 18 5.3 6 3.5 12 305 CAB-8 158 RL-02502 20 25 5.8 7.2 3.5 14 352 CAB-13V 210 RL-02502 25 25 5.8 7.2 3.5 14 352 CAB-13V 210 RL-03502 30 35 5.8 7.2 4 16 370 CAB-13V 210 RL-04502 40 45 7.4 9 4.7 28 555 CAB-13V 210 RL-05502 50 55 7 9 5.3 27 640 CAB-13V 210 RL-08002 60 80 7.2 9 6.5 33 853 CAB-13V 210 RL-08002 75 80 7.2 9 6.5 33 853 CAB-13V 210 RL-10002 100 100 7.3 9 6.8 37 841 CAB-13V 210 RL-13002 125 130 7.2 9 6.8 43 1,116 CAB-13V 210 RL-16002 150 160 8.3 10.8 6 50 1,602 CAB-13V 210 RL-20002B14 200 200 7.5 9 8.3 54 1,668 CAB-13V 210 RL-25002B14 250 250 8.5 10.8 9 80 2,120 CAB-17V 569 RL-32002B14 300 320 9 10.8 10 102 2,449 CAB-17V 569 RL-40002B14 350 400 11.25 15 11.5 118 3,932 CAB-17V 569 RL-40002B14 400 400 11.25 15 11.5 118 3,932 CAB-17V 569 RL-50002 500 500 11.5 14.4 11.5 118 4,379 CAB-26C 1,673 RL-60002 600 600 11.25 14.4 12 175 4,894 CAB-26C 1,673 RL-75002 700 750 11.5 14.4 12.5 190 6,100 CAB-26C 1,673

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - 600V-3% MTE REACTORS C - 47 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 600V-4% MTE REACTORS LIST PRICES LINE & LOAD REACTORS: CHASSIS 3-PHASE

Effective 05-01-18 VOLTAGE: Supercedes All Previous 600V-4%

600V 3-PHASE 4% IMPEDANCE OPTIONAL

HP DIMENSIONS (APPROX.) APPROX. WT. LIST NEMA 1 LIST CATALOGUE NUMBER AMPS RATING HEIGHT WIDTH DEPTH LBS PRICE ENCLOSURE PRICE RL-00203 1 2 4.1 4.4 2.8 4 219 CAB-8 158 RL-00202 1.5 2 4.1 4.4 2.8 4 191 CAB-8 158 RL-00404 2 4 4.1 4.4 3.4 6 226 CAB-8 158 RL-00404 3 4 4.1 4.4 3.4 6 226 CAB-8 158 RL-00804 5 8 4.8 6 3.4 13 303 CAB-8 158 RL-01203 7.5 12 5 6 3.9 18 347 CAB-8 158 RL-01203 10 12 5 6 3.9 18 347 CAB-8 158 RL-01803 15 18 6.1 8.1 4 16 403 CAB-13V 210 RL-02503 20 25 5.8 7.2 4.3 20 459 CAB-13V 210 RL-02503 25 25 5.8 7.2 4.3 20 459 CAB-13V 210 RL-03503 30 35 7.4 9 4.7 30 562 CAB-13V 210 RL-04503 40 45 7.3 9 5.3 39 710 CAB-13V 210 RL-05503 50 55 7 9 6 41 845 CAB-13V 210 RL-08003 60 80 8.5 10.8 6.8 61 1,489 CAB-13V 210 RL-08003 75 80 8.5 10.8 6.8 61 1,489 CAB-13V 210 RL-10003 100 100 8.25 10.8 6.16 74 1,684 CAB-13V 210 RL-13003 125 130 8.5 11 6.16 64 1,696 CAB-13V 210 RL-16003 150 160 8.5 11.5 9 67 1,875 CAB-13V 210 RL-20003B14 200 200 8.3 10.8 10 100 2,448 CAB-13V 210 RL-25003B14 250 250 11.2 14.4 10.3 125 3,815 CAB-17V 569 RL-32003B14 300 320 11.25 14.4 10.5 160 4,121 CAB-17V 569 RL-40003B14 350 400 11.25 14.4 12.5 149 4,563 CAB-17V 569 RL-40003B14 400 400 11.25 `14.4 12.5 149 4,563 CAB-17V 569 RL-50003 500 500 11.5 14.4 13.3 210 5,190 CAB-26C 1,673 RL-60003 600 600 11.25 14.4 15 270 6,608 CAB-26C 1,673 RL-75003 700 750 14.5 14.4 14 265 8,530 CAB-26C 1,673

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - 600V-4% MTE REACTORS C - 48 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 MTE SERIES FEATURES MODEL: MTE SERIES D dV/dT FILTERS

DESCRIPTION: Designed to protect AC Motors from the destructive effects Effective 05-01-18 of peak voltages facilitated by long cable runs between the Supercedes All Previous inverter and motor.

APPLICATIONS • Submersible Pumps • Process Automation Lines • HVAC Equipment

FEATURES • 3 to 600 Amp Range (0.5 to 600HP) • 480V to 600V, 50/60 Hz, 3-Phase • Max. Motor Peak Voltage Spec. (150% of DC Bus Voltage) at 1000 Feet • For use on VFD Systems with Switching Frequencies 2kHz to 5kHz • Protects Motors from Long lead Lengths and Standing Wave Phenomenon • Reduce Output Voltage dV/dT • Available in Chassis Style, NEMA 1 and NEMA 3R • 1 Year Warranty • cUL, CE Approved

Control Products - MTE SERIES dV/dT FILTERS C - 49 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 MTE SERIES LIST PRICES dV/dT FILTERS Protects Motors from Effects of Peak Voltages Caused by Long Cable Runs Select Filters Based on the Current Rating of the Motor

Effective 05-01-18 VOLTAGE: Supercedes All Previous 480V

SERIES A dV/dT FILTER, 480VAC, 60 Hz OPEN CHASSIS NEMA 1 NEMA 3R HP AMPS CATALOGUE NUMBER LIST PRICE CATALOGUE NUMBER LIST PRICE CATALOGUE NUMBER LIST PRICE 1 to 1.5 3 DVSP0003E 710 DVSG0003E 1,115 DVSW0003E 1,625 2 4 DVSP0004E 725 DVSG0004E 1,130 DVSW0004E 1,635 3 7 DVSP0007E 760 DVSG0007E 1,170 DVSW0007E 1,665 5 9 DVSP0009E 790 DVSG0009E 1,205 DVSW0009E 1,700 7.5 12 DVSP0012E 830 DVSG0012E 1,255 DVSW0012E 1,775 10 17 DVSP0017E 910 DVSG0017E 1,340 DVSW0017E 1,810 15 22 DVSP0022E 980 DVSG0022E 1,405 DVSW0022E 1,965 20 27 DVSP0027E 1,050 DVSG0027E 1,480 DVSW0027E 2,085 25 35 DVSP0035E 1,140 DVSG0035E 1,580 DVSW0035E 2,155 30 45 DVSP0045E 1,255 DVSG0045E 1,710 DVSW0045E 2,225 40 55 DVSP0055E 1,355 DVSG0055E 1,830 DVSW0055E 3,105 50 65 DVSP0065E 1,480 DVSG0065E 1,975 DVSW0065E 3,165 60 80 DVSP0080E 1,650 DVSG0080E 2,165 DVSW0080E 3,340 75 110 DVSP0110E 2,060 DVSG0110E 2,625 DVSW0110E 3,995 100 130 DVSP0130E 2,420 DVSG0130E 3,250 DVSW0130E 4,655 125 160 DVSP0160E 2,690 DVSG0160E 3,580 DVSW0160E 4,745 150 200 DVSP0200E 2,860 DVSG0200E 3,835 DVSW0200E 4,830 200 250 DVSP0250E 3,205 DVSG0250E 4,220 DVSW0250E 5,050 250 305 DVSP0305E 3,445 DVSG0305E 4,630 DVSW0305E 5,095 300 365 DVSP0365E 3,855 DVSG0365E 5,165 DVSW0365E 6,485 350 415 DVSP0415E 4,115 DVSG0415E 5,420 DVSW0415E 6,935 450 515 DVSP0515E 4,910 DVSG0515E 6,395 DVSW0515E 7,180 500 600 DVSP0600E 5,100 DVSG0600E 6,755 DVSW0600E 7,365

NOTE: (1) Items on this page are not stocked in TECO-Westinghouse warehouses. Please contact your TWMI representative for availability. (2) Prices subject to change without notice. (3) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - MTE SERIES dV/dT FILTERS C - 50 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 MTE SERIES LIST PRICES dV/dT FILTERS Protects Motors from Effects of Peak Voltages Caused by Long Cable Runs Select Filters Based on the Current Rating of the Motor

Effective 05-01-18 VOLTAGE: Supercedes All Previous 600V

SERIES A dV/dT FILTER, 600VAC, 60 Hz OPEN CHASSIS NEMA 1 NEMA 3R HP AMPS CATALOGUE NUMBER LIST PRICE CATALOGUE NUMBER LIST PRICE CATALOGUE NUMBER LIST PRICE 1 to 2 3 DVSP0003E 710 DVSG0003E 1,115 DVSW0003E 1,625 3 4 DVSP0004E 725 DVSG0004E 1,130 DVSW0004E 1,635 5 7 DVSP0007E 760 DVSG0007E 1,170 DVSW0007E 1,665 7.5 9 DVSP0009E 790 DVSG0009E 1,205 DVSW0009E 1,700 10 12 DVSP0012E 830 DVSG0012E 1,255 DVSW0012E 1,775 15 17 DVSP0017E 910 DVSG0017E 1,340 DVSW0017E 1,810 20 22 DVSP0022E 980 DVSG0022E 1,405 DVSW0022E 1,965 25 27 DVSP0027E 1,050 DVSG0027E 1,480 DVSW0027E 2,085 30 35 DVSP0035E 1,140 DVSG0035E 1,580 DVSW0035E 2,155 40 45 DVSP0045E 1,255 DVSG0045E 1,710 DVSW0045E 2,225 50 55 DVSP0055E 1,355 DVSG0055E 1,830 DVSW0055E 3,105 60 65 DVSP0065E 1,480 DVSG0065E 1,975 DVSW0065E 3,165 75 80 DVSP0080E 1,650 DVSG0080E 2,165 DVSW0080E 3,340 100 110 DVSP0110E 2,060 DVSG0110E 2,625 DVSW0110E 3,995 125 130 DVSP0130E 2,420 DVSG0130E 3,250 DVSW0130E 4,655 150 160 DVSP0160E 2,690 DVSG0160E 3,580 DVSW0160E 4,745 200 200 DVSP0200E 2,860 DVSG0200E 3,835 DVSW0200E 4,830 250 250 DVSP0250E 3,205 DVSG0250E 4,220 DVSW0250E 5,050 300 305 DVSP0305E 3,445 DVSG0305E 4,630 DVSW0305E 5,095 350 365 DVSP0365E 3,855 DVSG0365E 5,165 DVSW0365E 6,485 450 415 DVSP0415E 4,115 DVSG0415E 5,420 DVSW0415E 6,935 500 515 DVSP0515E 4,910 DVSG0515E 6,395 DVSW0515E 7,180 550 515 DVSP0515E 4,910 DVSG0515E 6,395 DVSW0515E 7,180 600 600 DVSP0600E 5,100 DVSG0600E 6,755 DVSW0600E 7,365

NOTE: (1) Items on this page are not stocked in TECO-Westinghouse warehouses. Please contact your TWMI representative for availability. (2) Prices subject to change without notice. (3) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - MTE SERIES dV/dT FILTERS C - 51 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 MTE SINE WAVE FILTERS FEATURES

MODEL: MTE SINE WAVE FILTERS DESCRIPTION: MTE Sine Wave Filters transform the output of a Variable Effective 05-01-18 Frequency Drive to a near perfect sinusoidal wave form. Supercedes All Previous

APPLICATIONS • Long Cable Runs • VFD Feeding a Step Up Transformer • Multi Motor Applications • Reduced Motor Noise

FEATURES • 2 to 700 Amp Current Range • 230, 480 & 600V, 50/60Hz, 3-Phase • For Use on VFD Systems with Switching Frequencies from 2kHz to 8kHz • 100% Rated RMS Current & Intermittent Current of 150% for 1 Minute • Protects Motors from Long Lead Lengths • Reduce Motor Temperature • Reduce Motor Audible Noise • Available in Chassis Style, NEMA 1 and NEMA 3R • cUL and CE Approved

Control Products - MTE SINE WAVE FILTERS C - 52 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 MTE SINE WAVE FILTERS LIST PRICES SINE WAVE FILTERS Designed to provide a pure sine wave output when driven from a VFD Select filters based on the current rating of the motor

Effective 05-01-18 VOLTAGE: Supercedes All Previous 230V

SINE WAVE FILTERS 230VAC 60Hz OPEN CHASSIS NEMA 1 NEMA 3R HP AMPS CATALOGUE LIST CATALOGUE LIST CATALOGUE LIST NUMBER PRICE NUMBER PRICE NUMBER PRICE 0.75 - 1 5 SWAP0005A 1,419 SWAGA0005A 1,637 SWAWA0005A 2,427 2 9 SWAP0009A 1,613 SWAGA0009A 1,896 SWAWA0009A 2,678 3 12 SWAP0012A 1,643 SWAGA0012A 1,926 SWAWA0012A 2,708 5 17 SWAP0017A 1,672 SWAGA0017A 1,953 SWAWA0017A 2,736 7.5 22 SWAP0022A 1,720 SWAGB0022A 2,643 SWAWB0022A 3,262 10 30 SWAP0030A 1,908 SWAGB0030A 2,829 SWAWB0030A 3,448 15 45 SWAP0045A 2,199 SWAGB0045A 3,082 SWAWB0045A 3,701 20 55 SWAP0055A 2,299 SWAGB0055A 3,182 SWAWB0055A 3,801 25 70 SWAP0070A 2,610 SWAGC0070A 4,523 SWAWC0070A 4,860 30 85 SWAP0085A 2,977 SWAGC0085A 4,948 SWAWC0085A 5,286 40 110 SWAP0110A 4,188 SWAGC0110A 5,749 SWAWC0110A 6,086 50 135 SWAP0135A 4,311 SWAGC0135A 5,847 SWAWC0135A 6,184 60 160 SWAP0160A 5,111 SWAGC0160A 6,866 SWAWC0160A 7,204 75 200 SWAP0200A 5,264 SWAGC0200A 8,392 SWAWC0200A 8,731 100 250 SWAP0250A 6,732 SWAGD0250A 10,985 SWAWD0250A 11,450 125 320 SWAP0320A 8,969 SWAGD0320A 12,946 SWAWD0320A 13,412

NOTE: (1) Items on this page are not stocked in TECO-Westinghouse warehouses. Please contact your TWMI representative for availability. (2) Prices subject to change without notice. (3) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - MTE SINE WAVE FILTERS C - 53 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 MTE SINE WAVE FILTERS LIST PRICES SINE WAVE FILTERS Designed to provide a pure sine wave output when driven from a VFD Select filters based on the current rating of the motor

Effective 05-01-18 VOLTAGE: Supercedes All Previous 460V

SINE WAVE FILTERS 460VAC 60Hz OPEN CHASSIS NEMA 1 NEMA 3R HP AMPS CATALOGUE LIST CATALOGUE LIST CATALOGUE LIST NUMBER PRICE NUMBER PRICE NUMBER PRICE 1.5 3 SWGM0003D 1,517 SWGG0003D 1,774 SWGW0003D 2,245 3 5 SWGM0005D 1,573 SWGG0005D 1,838 SWGW0005D 2,321 4 7 SWGM0007D 1,627 SWGG0007D 1,903 SWGW0007D 2,396 5.5 9 SWGM0009D 1,683 SWGG0009D 1,967 SWGW0009D 2,472 7.5 12 SWGM0012D 1,766 SWGG0012D 2,064 SWGW0012D 2,584 10 17 SWGM0017D 1,903 SWGG0017D 2,225 SWGW0017D 2,774 15 22 SWGM0022D 2,040 SWGG0022D 2,387 SWGW0022D 2,962 20 27 SWGM0027D 2,177 SWGG0027D 2,548 SWGW0027D 3,150 25 35 SWGM0035D 2,398 SWGG0035D 2,806 SWGW0035D 3,451 30 45 SWGM0045D 2,674 SWGG0045D 3,128 SWGW0045D 3,827 40 55 SWGM0055D 2,950 SWGG0055D 3,451 SWGW0055D 4,205 50 65 SWGM0065D 3,224 SWGG0065D 3,773 SWGW0065D 4,581 60 80 SWGM0080D 3,638 SWGG0080D 4,256 SWGW0080D 5,147 75 110 SWGM0110D 4,732 SWGG0110D 6,306 SWGW0110D 6,731 100 130 SWGM0130D 5,462 SWGG0130D 7,200 SWGW0130D 7,618 125 160 SWGM0160D 6,556 SWGG0160D 8,542 SWGW0160D 8,950 150 200 SWGM0200D 8,017 SWGG0200D 10,332 SWGW0200D 10,724 200 250 SWGM0250D 9,841 SWGG0250D 12,568 SWGW0250D 12,943 250 305 SWGM0305D 11,848 SWGG0305D 15,028 SWGW0305D 15,384 300 365 SWGM0365D 14,039 SWGG0365D 17,711 SWGW0365D 18,045 350 415 SWGM0415D 15,863 SWGG0415D 19,949 SWGW0415D 20,264 450 515 SWGM0515D 19,512 SWGG0515D 24,421 SWGW0515D 24,701 500 600 SWGM0600D 22,614 SWGG0600D 28,223 SWGW0600D 28,473 600 720 SWGM0720D 26,993 SWGG0720D 33,591 SWGW0720D 33,797

NOTE: (1) Items on this page are not stocked in TECO-Westinghouse warehouses. Please contact your TWMI representative for availability. (2) Prices subject to change without notice. (3) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - MTE SINE WAVE FILTERS C - 54 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 MTE SINE WAVE FILTERS LIST PRICES SINE WAVE FILTERS Designed to provide a pure sine wave output when driven from a VFD Select filters based on the current rating of the motor

Effective 05-01-18 VOLTAGE: Supercedes All Previous 600V

SINE WAVE FILTERS 600VAC 60Hz OPEN CHASSIS NEMA 1 NEMA 3R HP AMPS CATALOGUE LIST CATALOGUE LIST CATALOGUE LIST NUMBER PRICE NUMBER PRICE NUMBER PRICE 1.5 2 SWAP0002E 1,256 SWAGA0002E 1,497 SWAWA0002E 2,194 2 3 SWAP0003E 1,386 SWAGA0003E 1,627 SWAWA0003E 2,324 3 5 SWAP0005E 1,677 SWAGA0005E 1,924 SWAWA0005E 2,359 5 7 SWAP0007E 1,808 SWAGA0007E 2,068 SWAWA0007E 2,502 7.5 9 SWAP0009E 1,833 SWAGA0009E 2,094 SWAWA0009E 2,523 10 12 SWAP0012E 1,860 SWAGA0012E 2,124 SWAWA0012E 2,570 15 17 SWAP0017E 2,033 SWAGB0017E 2,404 SWAWB0017E 2,823 20 22 SWAP0022E 2,310 SWAGB0022E 2,515 SWAWB0022E 2,972 25 27 SWAP0027E 2,387 SWAGB0027E 2,603 SWAWB0027E 3,114 30 35 SWAP0035E 2,671 SWAGB0035E 2,878 SWAWB0035E 3,212 40 45 SWAP0045E 2,686 SWAGB0045E 2,886 SWAWB0045E 3,275 50 55 SWAP0055E 3,255 SWAGC0055E 4,150 SWAWB0055E 4,463 60 65 SWAP0065E 3,611 SWAGC0065E 4,366 SWAWB0065E 4,679 75 80 SWAP0080E 4,805 SWAGC0080E 5,847 SWAWC0080E 6,159 100 110 SWAP0110E 5,669 SWAGC0110E 6,825 SWAWC0110E 7,114 125 130 SWAP0130E 6,477 SWAGC0130E 10,235 SWAWC0130E 10,532 150 160 SWAP0160E 6,853 SWAGC0160E 10,897 SWAWC0160E 11,194 200 200 SWAP0200E 7,799 SWAGD0200E 11,733 SWAWD0200E 12,031 250 250 SWAP0250E 8,365 SWAGD0250E 13,342 SWAWD0250E 13,342 300 305 SWAP0305E 12,643 SWAGD0305E 17,224 SWAWD0305E 16,204 350 365 SWAP0365E 13,904 SWAGD0365E 17,483 SWAWD0365E 17,285 400 415 SWAP0415E 19,481 SWAGD0415E 23,041 SWAWD0415E 23,560 450-500 515 SWAP0515E 21,865 SWAGD0515E 27,871 SWAWD0515E 28,355 600 600 SWAP0600E 28,192 SWAGE0600E 33,666 SWAWE0600E 34,047 700 720 SWAP0720E 33,199 SWAGE0720E 39,203 SWAWE0720E 39,584

NOTE: (1) Items on this page are not stocked in TECO-Westinghouse warehouses. Please contact your TWMI representative for availability. (2) Prices subject to change without notice. (3) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - MTE SINE WAVE FILTERS C - 55 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 MTE MATRIX FEATURES MODEL: MTE MATRIX FILTERS

DESCRIPTION: MTE Matrix Filters meet the most stringent IEEE-519 Effective 05-01-18 requirements (5% THID) of removing current distortion on Supercedes All Previous virtually any kind of six pulse rectifier.

APPLICATIONS • Any VFD Loads • Induction Heating Equipment • Fans and Pumps • Water Treatment Facilities • Hospitals and Critical Applications

FEATURES • 6 to 786 Amp Current Range • 480 & 600V, 50/60Hz, 3-Phase • Capacitor Options & More • Epoxy Impregnated • High Saturation Current Rating • Performance Guarantee to Meet IEEE 519 • Generator Compatible • Available in Open Style, NEMA 1 or NEMA 3R • No System Analysis Required to Select and Apply Matrix Filters • cUL and CE Approved

Control Products - MTE MATRIX FILTERS C - 56 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 MTE MATRIX LIST PRICES MTE MATRIX FILTERS For use with 6 pulse Variable Frequency Drives to mitigate harmonics to less than 5% THID at full load current

Effective 05-01-18 VOLTAGE: Supercedes All Previous 480V

MTE SERIES D MATRIX HARMONIC FILTERS 480VAC 60Hz OPEN CHASSIS NEMA 1 NEMA 3R HP AMPS CATALOGUE LIST CATALOGUE LIST CATALOGUE LIST NUMBER PRICE NUMBER PRICE NUMBER PRICE 5 8 MAPP0008D 2,425 MAPG0008D 3,975 MAPW0008D 4,470 10 14 MAPP0014D 2,830 MAPG0014D 4,350 MAPW0014D 4,840 15 21 MAPP0021D 3,295 MAPG0021D 4,895 MAPW0021D 5,400 20 27 MAPP0027D 3,710 MAPG0027D 5,360 MAPW0027D 5,865 25 34 MAPP0034D 4,120 MAPG0034D 5,815 MAPW0034D 6,335 30 44 MAPP0044D 4,535 MAPG0044D 6,160 MAPW0044D 6,800 40 52 MAPP0052D 5,255 MAPG0052D 7,060 MAPW0052D 7,585 50 66 MAPP0066D 6,065 MAPG0066D 7,965 MAPW0066D 8,500 60 83 MAPP0083D 6,870 MAPG0083D 8,870 MAPW0083D 9,415 75 103 MAPP0103D 7,680 MAPG0103D 9,820 MAPW0103D 10,385 100 128 MAPP0128D 10,105 MAPG0128D 12,485 MAPW0128D 13,075 125 165 MAPP0165D 11,225 MAPG0165D 13,840 MAPW0165D 14,465 150 208 MAPP0208D 12,125 MAPG0208D 14,980 MAPW0208D 15,630 200 240 MAPP0240D 12,720 MAPG0240D 16,050 MAPW0240D 16,760 250 320 MAPP0320D 18,060 MAPG0320D 23,765 MAPW0320D 24,480 300 403 MAPP0403D 21,000 MAPG0403D 26,710 MAPW0403D 27,420 400 482 MAPP0482D 24,335 MAPG0482D 30,045 MAPW0482D 30,755 500 636 MAPP0636D 32,835 MAPG0636D 39,775 MAPW0636D 40,865 600 786 MAPP0786D 38,780 MAPG0786D 46,805 MAPW0786D 48,015 700 850 MAPP0850D 44,725 MAPG0850D 52,805 MAPW0850D 55,165 900 1000 MAPP1000D 56,610 MAPG1000D 66,595 MAPW1000D 68,140 1000 1200 MAPP1200D 62,555 MAPG1200D 73,490 MAPW1200D 75,155

NOTE: (1) Items on this page are not stocked in TECO-Westinghouse warehouses. Please contact your TWMI representative for availability. (2) Prices subject to change without notice. (3) F.O.B. Appropriate TWMI Warehouse unless otherwise noted. (4) Capacitor Contactor (-002) option is available, please contact your TWMI representative for a price and delivery.

Control Products - MTE MATRIX FILTERS C - 57 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 MTE MATRIX LIST PRICES MTE MATRIX FILTERS For use with 6 pulse Variable Frequency Drives to mitigate harmonics to less than 5% THID at full load current

Effective 05-01-18 VOLTAGE: Supercedes All Previous 600V

MTE SERIES D MATRIX HARMONIC FILTERS 600VAC 60Hz OPEN CHASSIS NEMA 1 NEMA 3R HP AMPS CATALOGUE LIST CATALOGUE LIST CATALOGUE LIST NUMBER PRICE NUMBER PRICE NUMBER PRICE 5 6 MAPP0006E 2,660 MAPG0006E 4,165 MAPW0006E 4,655 10 11 MAPP0011E 3,070 MAPG0011E 4,680 MAPW0011E 5,075 15 21 MAPP0021E 3,610 MAPG0021E 5,210 MAPW0021E 5,715 25 27 MAPP0027E 4,275 MAPG0027E 5,970 MAPW0027E 6,490 30 34 MAPP0034E 4,585 MAPG0034E 6,330 MAPW0034E 6,850 40 44 MAPP0044E 5,600 MAPG0044E 7,300 MAPW0044E 7,975 50 52 MAPP0052E 6,300 MAPG0052E 8,205 MAPW0052E 8,740 60 66 MAPP0066E 7,110 MAPG0066E 9,105 MAPW0066E 9,655 75 83 MAPP0083E 8,320 MAPG0083E 10,460 MAPW0083E 11,025 100 103 MAPP0103E 10,345 MAPG0103E 12,720 MAPW0103E 13,315 125 128 MAPP0128E 11,430 MAPG0128E 14,045 MAPW0128E 14,665 150 165 MAPP0165E 12,855 MAPG0165E 15,705 MAPW0165E 16,360 200 208 MAPP0208E 14,765 MAPG0208E 18,090 MAPW0208E 18,805 250 240 MAPP0240E 18,000 MAPG0240E 21,805 MAPW0240E 24,420 300 320 MAPP0320E 21,415 MAPG0320E 25,695 MAPW0320E 27,830 400 403 MAPP0403E 26,305 MAPG0403E 31,535 MAPW0403E 32,725 500 482 MAPP0482E 32,825 MAPG0482E 39,005 MAPW0482E 40,075 600 636 MAPP0636E 38,530 MAPG0636E 46,550 MAPW0636E 47,760 800 786 MAPP0786E 48,440 MAPG0786E 58,595 MAPW0786E 60,045

NOTE: (1) Items on this page are not stocked in TECO-Westinghouse warehouses. Please contact your TWMI representative for availability. (2) Prices subject to change without notice. (3) F.O.B. Appropriate TWMI Warehouse unless otherwise noted. (4) Capacitor Contactor (-002) option is available, please contact your TWMI representative for a price and delivery.

Control Products - MTE MATRIX FILTERS C - 58 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 PROGRAMMABLE SG2 LOGIC RELAYS FEATURES MODEL: SG2 PROGRAMMABLE LOGIC RELAYS

DESCRIPTION: SG2 PLR offers a solid alternative to using mechanical Effective 05-01-18 relays and timers / OP10 HMI Can be used with SG2 as well Supercedes All Previous as TECO VFD’s.

APPLICATIONS • Panel Upgrades • OEM Favorite

FEATURES • SG2 Available in Blind or with HMI Built-In • 24VDC or 85 to 240Vac • Built-In Modbus Available on Specific Models • FREE Software Available • Expansion Modules Available • Software Allows Ladder Logic Programming or Function Block Programming • Offline Simultation • Online Monitoring • HMI Can Be Used with SG2 and TECO VFD's • HMI Offers 4.3 Monochrome Graphic Panel 192 x 64 Pixels • UL, cUL, CE Approved

Control Products - SG2 PROGRAMMABLE LOGIC RELAYS C - 59 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 PROGRAMMABLE SG2 LOGIC RELAYS LIST PRICES SG2 PROGRAMMABLE LOGIC RELAYS Simple yet powerful, dependable yet affordable The SG2 PLR Includes the needed features at the industry’s lowest price

Effective 05-01-18 VOLTAGE: Supercedes All Previous 24V to 240V

SG2 PROGRAMMABLE LOGIC RELAYS

CATALOGUE CONTROL DISCRETE / DIGITAL ANALOG LIST COMMS DISPLAY KEYPAD MAX I/O NUMBER POWER INPUTS OUTPUTS INPUTS OUTPUTS PRICE SG2-10HR-A 85-240 VAC 6 4 0 0 Prog RS232 4 x 12 Char. 8 key 34 175 SG2-12HR-D 24 VDC 6 4 2 0 Prog RS232 4 x 12 Char. 8 key 36 155 SG2-12KR-D 24 VDC 6 4 2 0 Prog RS232 - - 36 132 SG2-20HR-A 85-240 VAC 12 8 0 0 Prog RS232 4 x 12 Char. 8 key 44 252 SG2-20VR-D 24 VDC 8+4 8 4 0 RS-232/RS-485 4 x 12 Char. 8 key 44 245 SG2-8ER-D 24 VDC 4 4 0 0 N/A N/A N/A N/A 100 SG2-8ER-A 85-240 VAC 4 4 0 0 N/A N/A N/A N/A 122 SG2-4AI 24 VDC 0 0 4 0 N/A N/A N/A N/A 195 SG2-2AO 24 VDC 0 0 0 2 N/A N/A N/A N/A 195 SG2-4PT 24 VDC 0 0 4-(PT100) 0 N/A N/A N/A N/A 245 SG2-EN01 24 VDC 0 0 0 0 ETHERNET/232 N/A N/A N/A 735 SG2-MODBUS 24VDC 0 0 0 0 RS-485 N/A N/A N/A 245

SG2 OPTIONAL HARDWARE CATALOGUE NUMBER DESCRIPTION LIST PRICE SG2-PL01 SG2 Programming Cable, RS-232 to SG2-Programming Connector 40 SG2-ULINK SG2 Programming Cable, USB to SG2-Programming Connector 82 SG2-SW-EDM SG2 Programming software on CD ROM. Also available as free download from Internet. 0 SG2-PM05 SG2 Memory Cartridge. 20 SG2-10PS-24 Power Supply 24 Volt Output 100 OP10 HMI Screen RS232, RS485 MODBUS 252 OP10-PL01 Programming cable for OP10 HMI 25

NOTE: (1) Prices subject to change without notice. (2) F.O.B. Appropriate TWMI Warehouse unless otherwise noted.

Control Products - SG2 PROGRAMMABLE LOGIC RELAYS C - 60 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 CUSTOMER SERVICE FIELD SERVICE AND START-UP ASSISTANCE

Effective 05-01-18 Supercedes All Previous

ACTIVITY RATE (CND $) DESCRIPTION

Basic Rate $120.00/Hr Up to 8 hours a day, Monday - Friday, 7:00am - 6:00pm

Weekday overtime and all hours prior to 7:00am or beyond Standard Overtime: $180.00/Hr 6:00pm and all Saturday time. Total time not to exceed 12 Extended weekdays and Saturdays. hours in any 24-hour period.

Special Overtime: All Sunday and Holiday work and all time in excess of 8 hours Sundays, Holidays and in excess of $240.00/Hr on Saturdays. Total time not to exceed 12 hours in any 24- 8 hours on Saturdays. hour period.

Auto mileage charges cover the use of company or personal Auto travel (round trip) $1.05/KM vehicles. Driving time is included in actual total time en-route from office to job site area.

Transportation expense at cost based on round trip fares for Transportation and Living Cost plus 15% personnel and equipment. Time involves actual total time en- Expenses route from office to the job site area.

Holdover and standby time (waiting or on call) is considered Same as service time and rendered at prevailing service rates. This Hold over and Standby time Service Time rate will be charged to retain a technician in the service job Rate site area in lieu of his/her incurring additional expense by returning to his/her headquarters.

If an authorized TECO-Westinghouse service representative performs a certified Controls start-up per the above field service rates, the 12 month standard warranty will be extended to 24 months from date of start-up, or 27 months from date of purchase, whichever is less.

NOTE: (1) Prices subject to change without notice. (2) Travel time will be rendered the same as Service Time Rates. (3) Parts and materials supplied in connection with Field Service work will be priced in accordance with the Company’s published Conditions of Sale and pricing policy. (4) Any Equipment Rental in connection with Field Service work will be billed at cost. (5) Any duties, visas or custom charges in connection with Field Service work will be billed at cost. (6) Any credit for warranty materials will be identified on the TWMI Service Report Form, which should be acknowledged by the customer’s signature each day. (7) All rates are subject to appropriate taxes.

Control Products - FIELD SERVICE AND START-UP ASSISTANCE C - 61 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 Blank C - 62 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

ENCLOSURES

There are two broad enclosure classifications: Breather / Drains OPEN and TOTALLY ENCLOSED. Each is divided into a number of specific types. The primary types are as follows: To prevent against damaging amounts of water, every standard TEFC motor is supplied with one or two drain holes in the lowest OPEN TOTALLY ENCLOSED point of the motor frame. This hole can easily be closed with a tapped pipe plug. Advantage Plus and Optim® TEXP motors are Drip-proof Non-ventilated Fan-cooled supplied with automatic Breather/Drains as standard equipment. Splashproof Explosion-proof Such breathers allow the motor to drain any condensed moisture Externally ventilated without allowing contaminants to be sucked into the motor Weather-protected Heat exchanger during operation. Breather/Drains can be installed in any TECO- Westinghouse motor on frame sizes 140T or larger. Breather Only those most frequently used will be discussed here. drains can also be installed or relocated to accommodate vertical mounting on any TECO-Westinghouse motor with the exception Drip-proof Enclosures of Optim® TEXP due to restrictions with the certifications.

The NEMA definition for this type of enclosure is “a drip-proof Space Heaters machine is an open machine in which the ventilating openings are so constructed that successful operation is not interfered with Space heaters can also be installed inside the motor enclosure to when drops of liquid or solid particles strike or enter the enclosure heat the inside air and maintain an internal temperature above at any angle from 0 to 15 degrees downward from the vertical.” In the ambient dew point. This assures that cooling air will not the drip-proof motor, the cooling air is drawn into the motor from condense and produce moisture inside the motor. Space heaters the outside and comes into direct contact with the winding, rotor, available for motors are the wrap-around type. Space heaters are and all other internal parts of the motor. Therefore, the internal rated for operation on 120V or 240V, 60 Hz, single phase power motor parts must be able to withstand any contaminants present and are installed in the stator winding end-turns. Space heater in the atmosphere in which the motor is located. leads can be terminated in the main conduit box or auxiliary box located off the main conduit box. The open drip-proof motor is designed to be an economical choice for most indoor applications where reasonably clean Rotating Shaft Seal environments exist. As the name implies, this motor is adequately Special protection is provided at the point where the motor protected so that water dripping from overhead will not be drawn shaft passes through the bearing housing in the form of an into the motor. The open drip-proof (ODP) should not, however, external flinger. This flinger keeps water, dust and other foreign be used on applications where washdown with hoses is apt to matter out of the motor that might enter the motor along the occur or when driving rain, fog or snow will occur. shaft. All motors are furnished with a rotating neoprene flinger or machined metal labyrinth seal. INPRO/SEALS™ are optional Totally Enclosed for Advantage Plus Motors. TEXP motors are furnished with shaft seals approved for hazardous locations as defined by CSA. A totally enclosed motor is designed to prevent the free exchange of air between the inside and the outside of the motor Sealed Leads housing, but not sufficiently tight to be termed airtight. When the motor is equipped with an integral fan that blows air over Additional protection against moisture is provided by a neoprene the exterior surface of the frame, the motor is classed as being seal through which each motor lead wire is brought out of the TOTALLY ENCLOSED FAN-COOLED (TEFC). Without an external- motor frame to the terminal box. This is a standard feature for all cooling fan, the motor is classed as being TOTALLY ENCLOSED TECO-Westinghouse motors. NON-VENTILATED (TENV).

Totally Enclosed Fan Cooled

Cooling of TEFC motors takes place due to a continuous flow of air over the outside surface of the motor. The motor’s surface is usually ribbed to obtain additional surface area for heat dissipation. The airflow is produced by a fan that is mounted on the shaft at the front of the motor. In order to provide power to drive this fan, the motor shaft is extended through the front of the motor and a suitable fan is mounted on this stub shaft. For protection and direction control of the airflow, a fan cover is installed over the fan. Fan covers are either fabricated with pressed steel or for severe duty applications constructed of cast-iron.

Induction Motor Reference Guide D - 1 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

ENCLOSURES

Explosion Proof Design Externally Ventilated Motors

The Standard explosion proof motor is to be used in Occasionally, an external cooling system is used. This is all hazardous atmospheres listed under the following necessary in case the motor’s own fan will not provide sufficient classifications: cooling; such as on certain duty-cycle applications, planer drives, certain slow speed motors, etc. In other cases, the motor Class I, Group D, gasoline, naptha, alcohols, acetone, lacquer may be located in an extremely dirty atmosphere where it is solvent vapors and natural gas desirable to connect the motor’s air intake to a source of clean Class II, Group E, metal dust including magnesium and air by means of a duct. In either case, the air discharge can aluminum or their commercial alloys either be into the room directly from the motor, or it can be Class II, Group F, carbon black, coal or coke dust carried away from the motor through a pipe. Class II, Group G, flour, starch or grain dust Motors with motor-mounted, separately driven blowers are Note: Under Class 1 only, there are two divisions which allow usually called “force ventilated.” some latitude on motor selection: Motors ventilated from an external source are called “pipe Generally, Class I, Division 1, locations are those in which the ventilated.” In this case, the air pressure can be supplied by an atmosphere is or may be hazardous under normal operating external blower, or an oversize fan can be used in the motor conditions. Included are the locations which can become itself to draw air through the intake duct and force it through hazardous during normal maintenance. An explosion-proof the motor. motor is mandatory for Division 1 locations. Enclosures Summarized Class I, Division 2, refers to locations where the atmosphere may become hazardous only under abnormal or unusual conditions Drip-proof, for installation: (breaking of a pipe, for example). In general, motors in standard enclosures can be installed in Division 2 locations if the motor In non-hazardous atmospheres not containing abrasive or has no normally sparking parts. Thus, open or standard totally conducting dusts, high concentrations of chemical or oil enclosed squirrel cage motors are acceptable, but motors with vapors and/or where hosing down or severe splashing is not open slip rings or commutators (wound rotor, synchronous or encountered. DC) are not allowed unless the or slip rings are in an explosion-proof enclosure. Optim® TEFC and Advantage Plus Totally Enclosed Fan Cooled, for installation: motors are approved for Class I, Division 2, Group B, C and D In non-hazardous atmospheres containing abrasive or environments. conducting dusts, high concentrations of chemical or oil vapors and/or where hosing down or severe splashing is encountered. Explosion proof motors bear a label that is certified by Underwriters’ Laboratories and CSA. This label can be applied Totally Enclosed Explosion Proof, for installation: only by a motor manufacturer, such as TECO-Westinghouse, whose facilities are under the constant supervision of In hazardous atmospheres as defined by CANADIAN Underwriters’ Laboratories and CSA. Once a motor is ELECTRICAL CODE (CEC) section 18. disassembled in the field, the label no longer applies, unless the work is performed in a plant approved by Underwriters’ Laboratories or CSA.

A Word of Caution

It is the user’s responsibility to specify the atmosphere in the plant in which motors are to be applied. The user normally receives a classification from their insurance company as to the type of motor enclosure to be used where a hazardous atmosphere exists. If the user asks for recommendations, ask him to get a classification from his insurance company.

Induction Motor Reference Guide D - 2 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

ENCLOSURES MECHANICAL CONSIDERATIONS

Frame Size Motor Mounting

Motor frame dimensions have been standardized with a Installation Requirements uniform frame size numbering system developed by NEMA. The current standardized frames for integral horsepower The factors to consider in connection with the mounting induction motors range from 143T to 449T. These standards requirements of the specific installation are: cover most motors in the range of 1 through 250 Horsepower. First, how is the motor to be mounted? The numbers used to designate frame sizes have specific meanings based on the physical size of the motor. The first two There are two main categories: digits are related to the motor shaft height and the remaining digit or digits relate to the length of the motor. 1) Some type of base that will accommodate standard motor feet. The shaft height of horizontal motors can be calculated by 2) Installation in such a way that a special mounting dividing the first two digits of frame size by 4. flange is required on the motor.

For example, a 256T frame motor would have a shaft height Second, in what position is the motor to be mounted? (“D”) dimension of 25/4 = 6.25 inches. Similarly, a 444T frame motor would have a shaft height of 44/4 = 11 inches. The possibilities include shaft: Horizontal The third digit of the frame size is related to the length of the Vertical motor. There is no general rule of thumb that can be easily At an angle applied to determine the length of the motor. Third, is other equipment to be mounted on the motor? It is important to note that when standard foot mounted motors have frame sizes that differ only in the third digit, the shaft This may include: diameters, shaft lengths and distance from the end of the shaft Pumps to the bolt holes in the feet on the shaft end of the motor will Brakes be the same. It is the motor length or distance from the drive Gears end bolt-down holes to the “front” bolt-down holes that will Zero-speed switches vary. Tachometers

Fourth, where is the conduit box to be located on the motor Frame Suffix Letters frame to best meet the needs of the installation’s wiring When a motor is provided with special mounting dimensions, arrangement? flanges or special shaft features, this is indicated by adding a suffix letter to its frame number. Two points must be checked:

FOR EXAMPLE: 1) The position of the conduit box on the motor frame. 2) The position of the conduit opening. A 254TS frame motor indicates that the motor has a shaft exten- sion length and diameter different from that of a 254T frame Conduit Box Location motor. The standard location for the conduit box is on the right-hand The standard suffix letters and their meanings are as follows: side when facing the “front” of the motor.

C ...... “C” flange mounting Definitions of “Front” D ...... “D” flange mounting E ...... Special shaft for elevator motors There is still some confusion regarding which end of a motor K...... (prefix on DC motors) – longer than standard is its “front.” Since this is a frequently used term, it is important overall length, but still has standard mounting that everyone is consistent. dimensions P & PH ...... Vertical P or PH flange mounting NEMA defines the “front” of a motor as the end opposite the T ...... Standard shaft for belted service TS ...... Standard short shaft for coupled service shaft extension. (“When a motor has a flange, the flanged end V ...... Vertical mounting is always considered to be the “rear”). X ...... Wound rotor crane and hoist motors with double shaft extension – sometimes used as a prefix to The reason for this is that most motors are mounted with the denote a very special frame such as explosion-proof shaft extension more or less hidden from view. Thus, the “front” Y...... Special mounting dimensions is the end you normally see. Z ...... Special shaft extension

Induction Motor Reference Guide D - 3 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

MECHANICAL CONSIDERATIONS

Foot Mounting P-Flange

Most of the mounting problems encountered can be solved The primary application of this flange is on such equipment as with one of the assembly combinations of a standard foot pumps and agitators where the motor is usually mounted in a mounted motor. A thorough understanding of the basic vertical position on top of the equipment. components and how they can be positioned will result in a greater use of standard motors. Vertical Mounting

The Frame includes the mounting feet and forms the When a horizontal motor is to be mounted in the vertical foundation for the complete assembly. It can be positioned position special considerations must be made to ensure proper with the feet in any plane . . . top, bottom or side. operation and motor life. The considerations are dependent on the motor shaft orientation. The Conduit Box can be located on either side of the frame. 1. Shaft Down: F-1 = Conduit box on right-hand side of frame when facing - Drain holes/breathers must be relocated to the lowest “front” of motor. part of the motor and the original holes plugged. (Except F-2 = Conduit box on left-hand side of frame when facing TEXP Motors) “front” of motor. - Drip cover should be installed for outdoor applications, or if motor is exposed to overhead/spraying moisture The conduit opening can be placed in any one of four positions - *NDE bearing must be locked with a shaft locknut 5000 by rotating the conduit box on its axis in 90º steps. frames and larger or if a Roller Bearing is installed on the DE. A standard motor can be adapted to any of these standard - C-Flange motors to be mounted on a pump must have mounting methods. TECO-Westinghouse will provide motors the DE BRG locked. The only axial movement will be the configured as ordered, either F-1 or F-2. Price adders may apply. internal clearance of the bearing.

Angle Mounting * Motor shall not be subject to additional axial loading from driven equipment. Where the application requires the shaft to be at an angle to the horizontal, special attention must be paid to the motor 2. Shaft Up: bearings. - Drain holes/breathers must be relocated to the lowest part of the motor and the original holes plugged. (Except Grease-lubricated ball bearings are suitable for operation at TEXP Motors) any angle. However, motors equipped with sleeve bearings or - If an inpro/seal is to be used it should be suitable for slipring induction motors are limited to angle mounting that vertical use with no expulsion port. does not exceed 10º from the horizontal.

Flange Mounting Coupling Methods

There are three basic types of flange mountings; each are Direct Drives designed to meet different installation requirements. Statistics show that only about one out of five machines operate C-Flange at the same speed as its driving motor. When the motor is directly connected to the load, the application considerations This type of flange is used with close-coupled pumps and are different than when some intermediate means is used to similar applications where the mounting holes in the flange increase or decrease the speed. are threaded to receive bolts from the pump. Normally the “C” flange is used where a pump or similar item is to be overhung Direct coupling of the motor to the load is practical if the load on the motor, which then must have feet. is to run at a standard motor speed. For these applications, specify “short shaft for coupled service.” D-Flange Belted Drives When the motor is to be built-in as part of the machine, such as on machine tools, the “D” flange is usually selected. Gear-chain-drives and belt-drives are most commonly used to The mounting holes in this flange are not threaded. Bolts obtain speed reduction between motor and driven machine. In protrude through the flange from motor side. Normally, “D” applying these drives to standard motors, two factors must be flange motors are supplied without feet, since the “D” flange checked: is generally used to mount the motor on the driven machine. The motor is lined up with the driven machine by tightening 1. Effect on motor bearings. the bolts to press the machined surface and ring of the flange 2. Effect on motor shaft. against corresponding surfaces.

Induction Motor Reference Guide D - 4 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

MECHANICAL CONSIDERATIONS

Each of these drives will impose some strain on the bearings Bearings and shaft of the motor. The amount of strain in each case establishes the practical maximum values of horsepower and Ball Bearings speed. The maximum values shown in Figure 7 have been established by NEMA to assure good bearing life and guard All anti-friction bearings are rated on the basis of the fatigue life against excessive shaft stress in the application of V-belt drives of the material. The “life” of a bearing is defined as the number to NEMA standardized frames. of revolutions completed (or hours at some given speed) before the first evidence of fatigue develops.

Motor Synchronous Max. Frame Speed, RPM HP This point is difficult to predict for an individual bearing. Therefore, statistical distribution is employed to predict bearing 256T 3600 25 life on the basis of the performance of a group of bearings. 445T 1800 200 445T 1200 125 The “minimum” life of a group of identical ball bearings is 445T 900 100 defined as the number of revolutions (or hours) that 90% of the group of bearings will complete or exceed before the first Figure 7. Maximum Horsepower V-Belt Drives Recommended by NEMA for NEMA Standardized Frames evidence of fatigue develops. The “average” life is 5 times the minimum life.

Non-Standard Belt Applications Both of these factors are based on bearings running at their rated load. For loads above or below this point, bearing life A user may want to use a belt drive on a motor outside of the varies inversely with the cube of the load: sizes listed in Figure 7. In such a situation, send all available information on the application to TECO-Westinghouse. This 3 Loada Lifeb must include the following information: = Loadb Lifea 1. Belt type (A, B, C, D, or E) and size 2. Number of belts 3. Sheave dimensions (pitch diameter, also face width Failure of ball bearings may be caused by: and weight) 4. Direction of belt pull (whether up, down, or some 1. Rough races caused by dirt …one reason why double- other angle) shielded sealed bearings are used is to minimize the 5. Centre Distance possibility of introducing dirt into the bearings.

There are several things that TWMI can do depending on the 2. Metal flaking or cracking from balls or races … caused by application: overloading.

1. In some cases, the standard motor may be suitable. 3. Worn or broken retainer … caused by faulty lubrication or 2. Engineers may be able to suggest some slight change in misalignment. We provide adequate lubrication and guard user’s drive details to permit the use of a standard motor. against misalignment by properly machining the parts.

Belt Tension 4. Bearing jammed by hardened grease … result of high temperature or contamination. All belt drives should include a means for adjusting belt tension. This may be a sliding base, slide rails or other device. The Using Speed-Torque Curves natural tendency of most operators is to run the belts too tight regardless of whether “V” belts or flat belts are being used. A A great deal can be learned about torque from speed-torque good rule to remember is this – a belt that never slips is usually curves. A typical speed-torque for an AC squirrel-cage motor is too tight. A properly applied belt will always slip slightly when shown on the following page. Such a curve tells what kind of starting under load. Tight belts shorten bearing life, and may jobs a specific motor can handle. cause vibration and shaft breakage. This speed-torque curve is typical for a whole family of motors, Under certain conditions of excessive shaft stress, the shaft may but for this discussion assume it is for a 10HP, 1200 RPM AC rupture before the bearing fails. squirrel-cage motor. Full-load torque is listed as 45 lb-ft (1).

This type of failure is usually encountered when a motor is In analyzing the solid-line motor curve, start at (2). This is the applied to a belted load which exceeds the NEMA standard for starting torque point which is one of the critical selection its particular rating (See figure 7). factors. The value is 150% of full-load torque, which of course, is 67-1/2 lb-ft for this specific motor.

Induction Motor Reference Guide D - 5 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

MECHANICAL CONSIDERATIONS

Now, moving up the curve, you see that the torque drops off a It is fairly obvious that as long as the torque curve of the driven bit as the motor picks up speed, until about 20% synchronous machine stays to the left of the motor speed-torque curve up speed is reached. At this point, the torque starts to increase and to the full-load point, the motor will be able to handle the job. continues doing so until about 75% speed is reached (3). The However, should any portion of the driven machine torque motor has now reached the maximum, or breakdown, torque. curve fall to the right of the motor speed-torque curve, then a The abscissa shows this point to be at 200% of full-load torque, different motor must be selected. which, when converted, equals 90 lb-ft. The speed is 900 RPM. FOR EXAMPLE: This is another critical selection factor, particularly where fluctuating loads are involved. No point in the duty cycle can The dotted line, labeled (5), is the speed-torque curve for a exceed this torque value. If it does, it will stall the motor. loaded ball mill. The complete curve falls within the operating area of the motor. From here on, as the motor approaches synchronous speed, the torque decreases. At (4) the motor has reached full-load torque The dash line, labeled (6), is the speed-torque curve for a loaded and is operating at full-load speed which is 1160 RPM. As would rolling mill. Here you see that the required starting torque falls be expected, it is at this point that the rated horsepower is beyond the capacity of this motor. Therefore, a different motor established. will have to be used.

The difference between the synchronous speed of the stator’s The motor speed-torque curve shown here is that of a NEMA rotating magnetic field and the speed of the rotor is termed design B motor. As you know, there is a number of other NEMA “slip.” With this motor, the slip is 40 RPM, or 3-1/3 percent. designs for polyphase squirrel-cage motors, ... namely: A, C, D and F. Each design develops a different set of characteristics. Each design is intended for a different use.

SPEED-TORQUE CURVE - NEMA B

Induction Motor Reference Guide D - 6 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

MECHANICAL CONSIDERATIONS

Environment Shock and Vibration mechanically abuse the complete motor causing breakage of mounting feet, frames, shafts and brackets, The Environment Check List itemizes the problem areas. If the fatigue terminal connections, damage bearings and produce motor is exposed to any of these conditions, provisions must be mechanical wear on insulation. made to protect the complete motor or its parts. Corrosive Agents eat away at insulation and exposed metal An understanding of the reasons for examining each of parts (air-gap surfaces, bearings, and shaft)… eventually cause these problems will help determine which type of insulation malfunction of these parts. is needed. Abrasive Agents erode protective coatings as well as exposed Environment Check List surfaces, causing breakdown of insulation, score critical bearing surfaces. Ambient Temperature Higher than 40ºC (104º F) Blanketing Agents deposit unwanted coatings on critical parts, Lower than -40ºC (-40º F) clog air vents and passages and reduce heat dissipation. This Altitude points up the need for frequent inspection when the motor is Above 3300 feet above sea level located in contaminated atmospheres because current overload Mechanical Abuse protection or ammeters on the control panel do not detect Shock overheating of the motor caused by obstructed ventilation. Vibration Contaminants Moisture collects on critical parts, causes shorting of electrical Corrosive Agents components and corrodes exposed metal parts. Chemicals Abrasive Agents High Ambient Temperature Dust Filings Since total temperature at the hottest spot and the insulation Sand temperature capability are the governing factors, there are two Blanketing Agents approaches that can be taken. Dust Lint 1. Use a higher class of insulation i.e. Class H in place of Class F. Snow This would allow an extra 25ºC to be utilized to offset the Moisture elevated ambient temperature. For example, a motor High humidity designed for a Class F insulation system but built with Water Class H insulation could theoretically operate satisfactorily Form in an ambient temperature of 65ºC instead of 40ºC. Consult Solid your local TWMI representative for individual evaluation. Liquid Gas PLEASE NOTE: Method of Movement At elevated ambient temperatures, the type of bearings and the Suspended in air bearing lubricant would also have to be carefully analyzed. Falling from above Force directed 2. Utilize the same insulation system but increase the motor frame size. This approach will lower the motors operating High Ambient Temperature primarily affects the insulation. It temperature rise thus making part of the temperature rise causes deterioration and accelerated aging. It also can reduce capability available to withstand the elevated ambient the viscosity of the greases in the bearings to the point where temperature. This is equivalent to oversizing the motor its lubrication value is impaired. horsepower. Low Ambient Temperature primarily affects lubrication. It can Low Ambient Temperature increase the viscosity of the grease in the bearings to the point where its lubrication value is impaired, especially during startup. 1. -41ºC to -50ºC (-41ºF to -58º F). Low temperature grease Extreme low temperatures can cause materials to become rated to minimum -50ºC must be used to ensure adequate brittle and prone to failure such as shaft breaks or cracked stator lubrication during startup and operation. Space Heaters housings. are strongly recommended, especially for interment duty applications. High Altitude where the thinner air has less cooling ability, causes excessive temperature rise in the motor.

Induction Motor Reference Guide D - 7 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

MECHANICAL CONSIDERATIONS MOTOR DESIGNS

2. Below -50ºC (-58º F). Special consideration to the frame and Each is a value unto itself, but each combines with the others to shaft material must be made. Ductile cast iron will be used produce a total result. A basic understanding of these values, to increase tensile and yield strength, 4140 steel will be individually and collectively, is necessary before any real used for the shaft material. Appropriately rated low proficiency in the application of motors can be attained. temperature grease must be used to ensure adequate Horsepower is the term used to define the rated size or power lubrication during startup and operation. Space Heaters capability of the motor and is expressed: are strongly recommended, especially for interment duty applications. Consult your local TWMI representative HP = (Torque x RPM) / 5250 for individual evaluation. From this formula it is easy to see the relationship between Other Reasons for Using Higher Insulation Classes Torque, Speed and Horsepower. Due to the fact that motors are rotating machines, the force the motor produces to do work Occasionally it is desirable to use a higher class of insulation in is expressed as Torque (discussed in detail later). Keeping this order to put more horsepower into a particular frame size or to Horsepower formula in mind, Torque can be expressed as: give the motor more capability to safely accelerate high inertia loads. Torque = (5250 x HP) /RPM It is this relationship between Horsepower, Torque and Speed High Elevation that must be understood before you can safely evaluate the proper motor for any given application. Most motor applications An additional factor that affects the motor’s ability to dissipate have very specific load requirements which require certain heat is the density of the surrounding air. With higher air Torque, Horsepower and Speed. The sales engineer can evaluate density, more heat can be transferred. Generally the density of what size motor or what Horsepower motor will produce the air at a specific location is very constant, but air density does Torque required to drive the load at specified speeds. For vary with elevation; thus, when motors are installed at locations example, using the same Horsepower formula, the motor’s where the elevation is substantially above sea level, Speed (RPM) can be expressed as: consideration must be given to this factor. RPM = (5250 x HP) / Torque Standard motors will operate successfully within their normal temperature rating at elevations up to 1000 meters If you need to know how much Torque a 200 Horsepower, 1784 (3300 ft) above sea level. When motors are to be operated RPM (4 Pole) motor can produce at full load (normal rated above this altitude, the motor design should be checked for its conditions) you would perform this calculation: suitability at the required elevation. Contact your local TWMI Representative for evaluation. When required, motor design can Torque = (5250 x 200HP) / 1784 RPM be modified to make them suitable for high elevation operation. Torque = 588 lb-ft HP ALTITUDE To illustrate the relationship of Speed and Torque further, we DERATING (FEET) will use the same 200HP rating but change the speed to 1185 FACTOR RPM (6 Pole): 3,300 – 5,000 0.97 Torque = (5250 x 200HP) / 1185 RPM 5,001 – 6,600 0.94 Torque = 886 lb-ft 6,601 – 8,300 0.90 In this example it is easy to see that a slower 6 Pole motor can 8,301 – 9,900 0.86 produce significantly more torque that a faster 4 Pole motor of 9,901 – 11,500 0.82 the same Horsepower rating.

Now lets consider a customer that requires a motor that can produce 875 Lb-ft of Torque but at a Speed of 3600 RPM (2 MOTOR DESIGNS Pole). We know from the previous example that a 200HP motor running at 1200 RPM (6 Pole) speed can produce 886 Lb-ft of Horsepower Formula Torque but, what size or Horsepower motor will produce this Torque at the faster speed of 3600 RPM? There are four conditions that define a motor’s performance characteristics: HP = (886 lb-ft x 3600 RPM) / 5250 HP = 607.5 HP Horsepower Torque This is a substantially larger and more expensive motor than the Speed 200HP motor. Temperature Rise

Induction Motor Reference Guide D - 8 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

MOTOR DESIGNS

Torque Terminology The next term, “pull-up torque” (also called “minimum torque”) is shown at (2). This is the minimum torque developed Torque and force are sort of blood brothers. The term “Force” in the “cusp” area just above starting torque. It should be noted is used when dealing in linear motion, and the term “Torque” that many motors do not develop this cusp characteristic. when dealing in rotary motion. “Breakdown torque” is the maximum torque that the motor Torque is a product of force (pounds) times radius (feet). Thus can develop without stalling. This is shown by the arrow at (3) the value is expressed in “pound-feet” which indicates “X” the as being the maximum value reached by the torque curve. This number of pounds at a one-foot radius (or any combination of characteristic is sometimes called “pull-out torque”. radius and force whose product equals “X”). “Full-load torque” is the torque that the motor develops in Torque is used two ways. In the case of a piece of machinery, producing rated horsepower at rated full-load speed, as shown torque indicates the rotational force required to drive the at (4). You might think of this as “rated torque”. machine. In the case of a motor, torque indicates the rotational force that the motor can produce. “Accelerating torque” is the “plus” torque developed by the motor that is beyond the torque required by the load at any The typical AC induction motor speed-torque curve shown given speed. It is shown by the shaded area between the below illustrates some of the various types of torque with which motor-torque curve and the load-torque curve at (5). you will be dealing.

“Starting Torque” is the torque developed at the instant the motor is started. In essence, the rotor is stationary, but only for a moment. The arrow at (1) shows starting torque. Starting torque is also called “locked-rotor torque” or “breakaway torque”.

TORQUE TERMINOLOGY

Induction Motor Reference Guide D - 9 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

MOTOR DESIGNS

NEMA Designs A, B, C Breakdown torque, on the other hand, is lower than that for either A or B. Although there is no definite point for breakdown It is important to understand the characteristics of each of these torque, its value is established at about 190% (10HP example – NEMA designs. In most cases you will use the standard NEMA B 85 1/2 lb-ft). design. However, there will be times when an A, C, D or F design will handle the job better. Full-load torque is the same as that for both A and B.

About the best way to become familiar with these The curve (1) is the same loaded rolling mill speed-torque characteristics is to analyze the speed-torque curves for each of curve shown below . Here you see that a design C motor can the NEMA designs. handle this load because of its higher starting torque. In keeping with the basic speed-torque rule, all parts of the load The graph shown below shows the speed-torque curves for curve fall to the left of the motor curve. NEMA designs A, B and C. Curve B is dotted because it was discussed on the previous page. Curve A is dotted because its NEMA C motors have a double-deck rotor in which the upper characteristics are much like those of curve B. As you will note, deck consists of a small, high-resistance winding. This upper design A has a slightly higher breakdown torque than design B. deck would be subject to severe heating during prolonged accelerations. For this reason, design C motors should not be Designs A and B are similar in basic characteristics. The used on applications requiring frequent accelerations or difference lies in the fact that starting currents for design B involving high inertia loads. The best feature of this design is motors are limited by NEMA standards. There is no limitation on its high starting and accelerating torque. starting current for design A.

As shown by the solid-line curve, a NEMA design C motor has a higher starting torque than either the A or B design. This torque is about 225% which, in the case of the 10HP example, is 101 lb-ft.

SPEED-TORQUE CURVE - NEMA C

Induction Motor Reference Guide D - 10 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

MOTOR DESIGNS

NEMA Design D In order to average out the load, a heavy flywheel is used to store energy from the motor during 343º of travel, and to give The solid-line curve in the following figure shows the up this energy during the 17º working portion of the cycle. characteristic of a NEMA design D motor. This design produces a very high starting torque (1) which is approximately 275% of Energy is removed from the flywheel by deceleration…. 10% full-load torque. However, it has no true breakdown torque, as slowdown is a typical value. In the example, the average evidenced by the fact that torque continues to decrease all the horsepower required is 40. Consider what will happen in one way up the speed ladder. case where a 40HP, NEMA B motor is used; and in the other case where a 40HP, NEMA D is used. Another somewhat unusual characteristic of this motor is its high slip at full-load torque (2). The particular curve is that of a At point (3) on the accompanying graph, the NEMA B motor design D motor having a slip of 10%. However, design D motors is running at 90% of synchronous speed (10% slowdown) and with other values of slip are made. Two different designs have 165% of full-load torque (65% overload). However, note that been standardized…one is the 5 to 8% slip motor, and the other the NEMA D motor is running at just about full load (at 10% is the 8 to 13% slip motor. Special designs can be made with slip slowdown). values up to as much as 20%. Actually, a NEMA B motor would never let the flywheel slow The characteristics of this design are useful in meeting the down to 90% synchronous speed, because of the great increase needs of two broad application categories. First, the high in torque. The NEMA B motor will try to force the flywheel to starting torque equips this motor to handle hard-to-start loads, run at a much higher speed, thus overloading the motor and particularly of the pulsating type. Second, the sloping speed- preventing the flywheel from giving up a large portion of the torque curve fits this motor for application where it is desirable usable kinetic energy it has stored. to have the motor slow down during periods of peak load so that flywheel energy of the load can be released. Typical The advantage then, of the high-slip NEMA D motor is its ability applications include press brakes and punch presses. As soon to “roll with the punches” on flywheel applications. as the peak load has passed, the motor brings the flywheel back up to speed in preparation for the next peak.

FOR EXAMPLE:

A 120-ton, 6 inch stroke straight press is being used to punch 1/2 inch thick discs. The stroke length and the thickness of the metal being cut indicate that this press is doing the work only 17º of flywheel. SPEED-TORQUE CURVE - NEMA D

Induction Motor Reference Guide D - 11 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

MOTOR DESIGNS

NEMA Design F It is understandable why the applications of design F are limited. In general, these motors are used only for easy-to-start The speed-torque curve of a NEMA design F motor shows that loads where low starting currents are required and low torque this motor has a very low starting torque and only a moderate are acceptable. Because of its limited overload capacity, this breakdown torque. However, this motor has one desirable motor must be matched to the load very carefully. Typical characteristic…a low inrush current is required for starting. applications include fans and centrifugal pumps.

SPEED-TORQUE CURVE - NEMA F

Induction Motor Reference Guide D - 12 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

POWER SUPPLY

Comparison of NEMA Design Characteristics In many large cities where 120/208 volt networks are employed, commercial and small industrial loads are usually 200 volt, 3 The foregoing discussion of speed-torque curves emphasizes phase, 60 Hz. All Optim® motors up to 125 Horsepower are the fact that the five basic NEMA designs vary from one another usable on 208 volt networks however, motor torque, current to two important points… and efficiencies will be greatly effected.

STARTING TORQUE and BREAKDOWN TORQUE. An over-all Motors for 2300V/4160V can be furnished on motor frames picture of the relationship of these values is shown below. 444T and larger. Usually, because of the cost of starting equipment for this higher voltage, 2300V/4160V motors are rarely used below 150 Horsepower. Global Series motors rated How NEMA Speed-Torque Characteristics Are Classified for 2300V/4160V are available from 100 to 1250 Horsepower (Contact your local TECO-Westinghouse Representative for more NEMA DESIGN A information). Starting Torque NORMAL - Starting Current NORMAL Breakdown Torque HIGH – Full-load slip LOW Locked Rotor kVA Code Letter

NEMA DESIGN B When AC motors are started with full voltage applied (across-the-line starting), they draw line currents substantially Starting Torque NORMAL – Starting Current LOW greater than their full load running current. The magnitude of Breakdown Torque MEDIUM – Full-load slip LOW the “Inrush Current” is a function of motor Horsepower and the design characteristics of the motor. In order to define the inrush NEMA DESIGN C characteristics and present them in a simplified form, a series of code letters have been established. These code letters group Starting Torque HIGH – Starting Current LOW motors depending on the range of inrush values and express Breakdown Torque NORMAL – Full-load Slip LOW the inrush current in terms of kVA (Kilovolt Amperes).

NEMA DESIGN D By using the kVA basis, a single letter can be used to define both the low voltage and high voltage inrush values on dual voltage Starting Torque VERY HIGH – Starting Current LOW motors. Full-Load Slip HIGH The code letter designations and their values appear in the NEMA DESIGN F following table:

Starting Torque LOW – Starting Current VERY LOW kVA/HORSEPOWER CODES Breakdown Torque VERY LOW CODE kVA/HP MID-VALUE Full Load Current A 0.00 – 3.14 1.6 B 3.15 – 3.54 3.3 As the torque on a motor increases, the line current (amperage) C 3.55 – 3.99 3.8 increases. The electrical wiring and controls providing power to the motor must be adequately sized to handle the maximum D 4.00 – 4.49 4.3 sustained current that the motor requires when it is fully loaded. E 4.50 – 4.99 4.7 F 5.00 – 5.59 5.3 Thus, the electrician installing the motor must use the nameplate “Full Load Current” data to correctly size the power G 5.60 – 6.29 5.9 supply wiring and starter for the motor. In addition, once the H 6.30 – 7.09 6.7 motor has been put into service, line amperage can be utilized J 7.10 – 7.99 7.5 to determine if the motor is being overloaded. It is important to note that the motors line current and operating temperature K 8.00 – 8.99 8.5 will increase when it is subjected to either undervoltage or L 9.00 – 9.99 9.5 overvoltage. M 10.00 – 11.19 10.6 N 11.20 – 12.49 11.8 Voltage P 12.50 – 13.99 13.2 In most industrial plants the power supply usually found for the R 14.00 – 15.99 15.0 average size polyphase motor is 460 or 575 volts, 3 phase, 60 Hz and the majority of T-Frame motors sold fall in this voltage and frequency class.

Induction Motor Reference Guide D - 13 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

POWER SUPPLY

To determine the across the line starting inrush amperes from 60 Hz. Therefore, a motor rated 100HP at 60 Hz is normally the code letter designation, the code letter value, horsepower, rated for 83HP when operated on 50 Hz power. The and rated operating voltage are inserted in the following conservative design of many TECO-Westinghouse motors equation. allows for 50 Hz operation without HP de-rating. Contact your local TECO-Westinghouse representative for more ((code letter value) x HP x 577) details. Locked Rotor Amps = Rated Voltage • Torque, current and efficiency values will also be different The simplified equations will give approximate results. for motors when operated on 50 Hz power. Contact your local TECO-Westinghouse representative for these values 200 Volts: L R A = Code letter value x HP x 2.9 when using a motor with 50 Hz power. 230 Volts: L R A = Code letter value x HP x 2.5 460 Volts: L R A = Code letter value x HP x 1.25 Service Factor 575 Volts: L R A = Code letter value x HP x 1.00 A horsepower rating does not necessarily indicate a motor’s The Performance data table gives the kVA/HP code letter for maximum capacity. This is where “service factor” enters the each rating. Generally, standard motors of 15HP or larger, will picture. Service factor is a multiplier that indicates how much have code letters for G, or lower, 10HP and smaller will have the motor may be safely overloaded. code letters of H, or higher. The service factor is applied simply by multiplying it times the Rated Frequency and Number of Phases rated horsepower. The result is the maximum horsepower at which the motor may be operated. This indicates the frequency for which the motor is designed in Hertz (cycles per second). Hertz is normally abbreviated Hz. It is important to remember that the value obtained by applying 60 Hertz power is utilized throughout the United States and a service factor is valid only if usual service conditions, rated Canada. 60 Hertz is also in a few foreign countries where there voltage and rated frequency are maintained. Also, it should be has been a strong American influence, however, 50 Hertz is the noted that the resultant overloaded state will increase the dominant system frequency in the majority of foreign countries. temperature rise and may affect the motor’s efficiency, power When motors are supplied for export shipments, it is vitally factor and speed. The resulted increase in temperature rise can important to double check the required voltage and frequency. drastically reduce motor life, for every 10°C increase in motor temperature the expected life of the motor winding is cut in In most industrial and commercial installations, the power half. systems, and consequently the induction motors, will either be single phase or three phase. The simplicity of the 3 phase Example of how service factor is applied: induction motor makes it the natural choice for all requirements where 3 phase power is available. Single phase motors may be SQUIRREL-CAGE, TEFC, 40ºC used on fractional horsepower requirements (less than 1HP) and in applications such as agricultural installations where 3 phase 10 rated horsepower power is not available. X 1.15 service factor 11.5 overloaded capacity (HP)

50 Cycle Motors CHANGE IN TORQUE AND SPEED (1800 RPM Motor)

While it is best to have a motor specifically designed for 50 Hz 30.1 x 1745 = 10 HP power systems, it is possible to use 60 Hz rated motors with 50 5250 Hz power supply provided the following conditions are satisfied: 35 x 1728 = 111/2 HP • In order for the motor to operate safely within thermal 5250 limits and generate sufficient output, it is important that balanced frequency and voltage power is supplied to the Actually, a service factor is an indication of a motor’s safe motor. Therefore, a motor designed for 460 volt, 60 Hz, is internal operating temperature. When a horsepower rating is normally operated on the following voltage for 50 Hz established for a specific motor design and size, it is based on power: two factors: (1) the total power that the motor can produce, and (2) the amount of internal heat that the motor insulation 60 Hz / 460 V = 50 Hz / Preferred Voltage can withstand. Preferred Voltage = (50 Hz x 460 V) / 60 Hz Preferred Voltage = 383 V or 380 volts The internal heat factor usually dictates a rating below the motor’s momentary power output capacity. In addition, a • The rated performance of a motor will change when margin of safety is often applied to the internal heat factor. It operated on 50 Hz power. Horsepower output will be is this margin of safety that makes the service factor possible. approximately 50 Hz / 60 Hz = 83% of its rated value at

Induction Motor Reference Guide D - 14 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

MOTOR EFFICIENCY

Motor Efficiency Payback Analysis

A perfect motor would be a motor that could convert electrical Competitor Motor’s Yearly Energy Cost

power to mechanical power with 100% efficiency. Expressed 74.6 KW 24 Hours 340 Days $38,855 = X X X $0.06 per KW Hour mathematically, the perfect motor would convert 746 watts 0.94 Eff. Day Year of electrical power to one horsepower of mechanical output power. TWMI Motor’s Yearly Energy Cost

74.6 KW 24 Hours 340 Days $38,609 = X X X $0.06 per KW Hour Real motors are not able to achieve this ideal goal, however, the 0.946 Eff. Day Year larger a motor becomes, the closer it will come to approaching 100% efficiency. In most cases the efficiency of a motor is Savings approximately constant, when operated at 1/2 or more of its full load torque rating. COMPETITOR $38,855 Yearly Energy Cost $2,718 Motor Price

The motor’s losses or energy that is not converted into TWMI -$38,609 Yearly Energy Cost -$3,087 Motor Price mechanical power turns into heat within the motor frame. SAVINGS $246.00 Per Year $369 This heat must be transferred out of the motor via the cooling medium (see the section on Enclosures for more detail). Pay Back Period

A motor’s efficiency is expressed as: 1.5 Payback Years = $369 Price Difference $246 Energy Cost Difference Output KW Efficiency = (Output KW + Losses) In this example, a high quality, energy efficient Optim® motor that costs a full 12% more than the competition’s is in the long 1 Losses = Output x run a much less expensive motor to own and operate. ( Efficiency – 1 )

Premium Efficiency motors are specifically designed for low STARTING METHODS losses and to be highly efficient. This is important to industrial plants which operate large numbers of electrical motors which Starting Methods for Squirrel Cage Motors utilize great amounts of electrical power. Although Premium Efficiency motors are more expensive than the average motor, All of our AC motors are designed and built to withstand they pay for themselves over long periods of time with the full-voltage starting. money saved on utility bills. The following page provides an example of how TECO-Westinghouse Premium Efficiency However, there may be conditions which would dictate the use Optim® TEFC motors can save the customer money. of reduced voltage starting. They are: TECO-Westinghouse Motors (Canada) Inc. 1. kVA inrush limitations imposed by the power company 2. Mechanical shock to driven equipment Energy Saving Example 3. Excessive voltage drip and its effect on adjacent equipment This example compares two 100HP, 1800 RPM, 460 Volt, TEFC, In many countries, the star-delta system of starting is employed. 1.15 Service Factor Motors. Here, the control first connects the motor windings in star for starting and after the motor is up to speed, connects the Required Information: winding delta for running. By starting with the windings Efficiency of Competition’s Motor 94.0% connected star, the inrush is reduced by 57% of what it would be had the motor been started delta connected. The starting Efficiency of TWMI’s Motor 94.6% torque and pullout torque are reduced to 34% of the normal values so that this method of starting is limited mostly to Price of Competition’s Motor $2,718.00 machines started unloaded.

Price of TWMI’s Optim® TEFC Motor $3,087.00 When reduced voltage starting is desired for squirrel cage motors having normal windings, there are three types of Energy Cost per Kilowatt (KW) Hour $0.06 controls:

Days of Motor Operation Per Year 340 1. Auto-transformer 2. Resistor Hours of Motor Operation per Day 24 3. Reactor Kilowatt (KW) Rating of Motors (0.746 x HP) 74.6

Induction Motor Reference Guide D - 15 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

STARTING METHODS

Auto-Transformer The table at the top lists typical values of voltage, current and torque obtained with some of the most common methods of An auto-transformer starter is essentially a transformer with reduced-voltage starting. a step-down tap plus a switching device that connects the motor to the transformer for starting and directly to the line for As indicated, the values shown in this table are the percent of running. The transformer taps are normally supplied for values the corresponding value that would be obtained if full-voltage of 50%, 65% or 80% of the line voltage. Starting torque varies starting were used. Take the case of the auto-transformer. If an as the square of motor terminal voltage. The values for the three 80% voltage starting current, and the starting torque would be standard taps are as follows: 64% of the full-voltage starting torque.

For the moment, the main consideration is the last column…. Auto-transformer Tap Starting Current Starting Torque percent of full-voltage torque. This shows that with resistor, % Line Voltage % Normal % Normal reactor or auto-transformer starting, the starting torque varies as the square of the motor terminal voltage. With part-winding 50% 25% 25% starting, the starting torque varies directly as the portion of the 65% 42% 42% winding that is used for starting. With star-delta starting, the starting torque is always 33% of the full-voltage starting torque. 80% 64% 64% The resulting starting-torque values, based on the data in the table, are plotted on the speed-torque curve at the bottom Resistor of the page. The full-voltage curve is that of a NEMA design B motor. Other NEMA designs would, of course, produce other This method utilizes a resistor in series with each phase of reduced-voltage curves. It should be remembered that the the motor, to reduce line current for starting. The resistors reduced-voltage curves apply only during the starting period. are short-circuited when full speed is reached. If a high value As soon as full voltage is applied, the motor characteristics then resistor is short-circuited in increments, it is possible to increase revert to the full-voltage values. the line current gradually until a value is reached that is adequate to start the load.

Reactor

Reactor starting is not as common as resistor or auto- transformer starting, but there are occasions when it can be used to good advantage. The method is very similar to the resistor method, except that series reactors are used instead of resistors. Short-circuiting the reactor for running is similar although step short-circuiting is not generally feasible. This method of starting is more commonly used with higher voltage motors 2300 volts and above.

Reactors are also used as inductive devices to filter unwanted harmonics and voltage spikes generated by variable frequency drives.

Effect of Reduced Voltage Starting

The starting torques discussed so far are those values obtained when full voltage (across-the-line) starting is used. However, there are cases where the current required for full-voltage starting cannot be permitted, and thus reduced-voltage starting must be used to limit the starting current. In as much as torque varies as the square of the applied voltage, the values of starting torque will decrease when reduced-voltage starting is used. An indication of the result is shown on the following page.

Induction Motor Reference Guide D - 16 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

STARTING METHODS

REDUCED - VOLTAGE SPEED - TORQUE CURVES

PERCENTAGE OF FULL VOLTAGE Voltage Current Torque RESISTOR 80% 80% 64% REACTOR 80% 80% 64% PART WINDING - 65% 100% AUTO TRANSFORMER 80% 64% 64% STAR-DELTA 57% 57% 33%

Induction Motor Reference Guide D - 17 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

VFD DRIVEN MOTOR APPLICATIONS

Variable Speed Applications Motor Insulation System & Supply Voltage

A variable frequency drive allows a customer to change the The motor insulation system for VFD approved TECO- motor’s operating speed by changing the frequency (Hz) of the Westinghouse motors is based on and exceeds NEMA power supplied to the motor. While this is convenient for the Standards. As defined in NEMA MG-1 Part 31.4.4.2 the insulation customer, it causes several problems for the motor and special system must be capable of withstanding voltage spikes of 3.1 consideration must be given to the motor’s ability to operate on x rated line-to-line voltage for motors rated ≤600V and 2.04 various frequencies. x rated line-to-line voltage for motors rated >600V with a rise time of ≥ 0.1μs. TECO-Westinghouse motors rated ≤600V have • Motors operated below their approved turn down ratio do been designed to withstand voltage spikes up to 2000V with a not move enough air to adequately cool the motor. This will rise time of ≥ 0.1μs. cause the motor to run hot and decrease the motor’s life. Voltage spikes and rise time should be measured at the motor • Motors operated above 60Hz will experience decreased terminals and should not exceed the above given values. torque output. Additionally, care must be taken to ensure the motor, and all mechanical devices driven by the motor, Cable Length & Type are able to withstand these higher RPMs. Please contact your TECO-Westinghouse representative for the maximum Cable length and type connecting the motor and drive have safe operating RPM of your motor. a significant influence on the peak voltages occurring at the motor terminals. Effects of Harmonics on Induction Motors Cable Length Power supplied by (PWM) variable frequency drives contain harmonic content in the electrical waveforms they generate at The following conditions should be met when installing various frequencies. The harmonic content and non-sinusoidal TECO-Westinghouse motors on an inverter: waveforms generated by the drive can cause the following problems: LOAD REACTOR SINE-WAVE VOLTAGE NO DV/DT FILTER AT VFD FILTER CLASS FILTERS RECOMMENDED • High harmonics in the waveform increase the motor’s RECOMMENDED RECOMMENDED “hot-spot” causing the motor to run hotter than it would under normal conditions. 100 - 1001 - 2001 - ≤480V (LV) <100 ft. 1000 ft. 2000 ft. 3000 ft. • Voltage spikes at the motor terminals resulting from >480V - 301 - 2001 - harmonics & reflective wave can exceed the rated peak <35 ft. 36 - 300 ft. 690V (LV) 2000 ft. 3000 ft. voltage of the motor winding. The magnitude of the voltage spike and rise time is a function of the inverter switching speed (carrier frequency). Note: Extended cable lengths and greater motor protection can also be realized through the use of solid state surge • Harmonic frequencies generated by the VFD could excite protection devices. Some configurations may yield a greater resonance in the motor frame resulting in increased noise cable length protection then those specified. and vibration levels. Although filters may not be required at some cable lengths, • Corona effect causing partial discharge on the motor they are always recommended to better protect both the motor windings leading to insulation breakdown. and VFD.

• Capacitive discharge from the motor shaft to ground causing Please contact TECO-Westinghouse for application specific pitting of the bearings leading to bearing failure. recommendations.

Cable Type

VFD approved shielded cable is recommended to minimize the effects of reflected wave, provide a proper grounding path attributing to a balanced and low reference potential and reduce the commode mode voltage.

Induction Motor Reference Guide D - 18 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

VFD DRIVEN MOTOR APPLICATIONS

Motor Shaft Voltages & Bearing Currents VFD Carrier Frequency Settings

Shaft voltages and resulting circulating currents caused by High switching frequencies increase the rate of current magnetic dissymmetry’s in the construction of larger motors, discharge through the bearings and increase the rate of typically 5000 frames and larger, can be increased by the insulation breakdown in the motor windings. The carrier effects of high frequency components present in the voltage frequency should be set between 2 kHz and 5 kHz. supplied by PWM inverters. The path of these induced currents is through the bearings and motor frame and can be prevented VFD Application in Hazardous Locations by insulating one of the bearings, preferably the non-drive end bearing, to avoid creating a loop through the driven equipment. Motors operated on VFD power in hazardous areas require special consideration; please contact TWMI for filtration Common mode voltages imposed on the rotor by capacitive and bearing protection options suitable for use in these coupling between the rotor and stator can result in discharge applications. through one or both bearings to ground; therefore insulating both bearings is required to prevent current flow. Shaft grounding brushes may also be used to divert current around the bearings and to prevent the current from damaging the driven equipment.

Electrical discharge through the bearings causes an electric discharge machining (EDM) effect, resulting in pitting of the bearing’s rolling elements and raceways. Eventually this will lead to bearing failure and leaves a distinct pattern in the bearing race called “fluting”.

The following conditions should be met when installing TECO- Westinghouse motors on a VFD:

FRAME SHAFT GROUND INSULATED INSULATED SIZE BRUSH / RING NDE BEARING DE BEARING ≤ 400T Recommended - - 440T Recommended Recommended - ≥ 5000 Recommended Recommended Recommended

Note: It is not advisable to use shaft ground brushes on both ends as this will provide a path for circulating currents.

An alternate method of reducing damaging shaft currents is with the use of dV/dt or Sine-wave filters on the output of the VFD.

Induction Motor Reference Guide D - 19 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

INSULATION

Insulation Types and Temperature Rise 2. Phase Insulation: The various coils in a motor are connected together in the Functions of Motor Insulation three phases. The coils in one phase must be insulated from the coils in another phase. TECO-Westinghouse uses a sheet Motor insulation has two basic functions: of either Dacron Glass Cloth or DMD (Dacron Mylar Dacron) between the coils of the different phases. 1. It separates the various electrical components from one another. 3. Ground Insulation: The winding must be insulated from the stator iron in the 2. It protects itself and the electrical components from attack motor. An insulation barrier (slot liner) of DMD (Dacron Mylar of contaminants and other destructive forces. Dacron) is placed in the slot. To best perform these functions, five specialized elements are 4. Slot Wedges: used, which together constitute the INSULATION SYSTEM. The The wedges are made of DMD and hold the conductors following are typical in an AC motor: firmly in the slot. 1. TURN-TO-TURN INSULATION between separate wires in each 5. Varnish: coil. (Usually enamel on random-wound coils of smaller The complete winding is given a non hydroscopic motors – tape on “form-wound” coils or larger motors). polyester varnish immersion and oven cure to bond the above materials together as well as the individual turns in 2. PHASE-TO-PHASE GROUND INSULATION between adjacent the coil. This gives a good protective seal against moisture coils in different phase groups. (A separate sheet material on and contaminants. All motors receive two immersions and smaller motors – not required on form-wound coils because oven cure cycles. The bake-cycle is from 3 to 17 hours the tape also performs this function). depending on the size. 3. PHASE-TO-GROUND INSULATION between windings as a Insulation Types and Temperature Rise whole and the “ground” or metal parts of the motor. (A sheet material, such as the liner used in stator slots, provides both One of the most critical items relating to the life of any type of dielectric and mechanical protection.) electrical equipment ranging from television sets to giant power generators is the maximum temperature that occurs at the 4. SLOT WEDGE to hold conductors firmly in the slot. hottest point within the unit and the length of time that the high temperature is allowed to exist. 5. IMPREGNATION to bind all other components together and fill in the air spaces. (A total impregnation, applied in To draw an analogy: The aging process in human beings is to a a fluid form and hardened, provides protection against large extent determined by years and stress. Accidents, natural contaminants). disasters, diseases and other illnesses can intervene to shorten an individual’s life expectancy in the same way that lack of proper maintenance, overloads, moisture, chemical fumes, low CROSS SECTION OF STATOR COILS AND INSULATION and high voltages can shorten motor life.

Similarly, basic motor insulation life, when not complicated by these factors, is determined by time (age) and temperature (stress).

The maximum allowable safe operating temperature occurring at the hottest spot within a motor is determined by:

1. The temperature of the air surrounding the motor. This is the ambient temperature. 2. The heat created within the motor due to its operation at a fully loaded condition. This is the temperature rise. 3. The thermal capability of all the insulation materials used within the motor. For simplicity these materials have been broken into classes A, B, F and H.

1. Turn-to-Turn Insulation: A coil consists of a number of turns of round copper wire. These turns of wire are insulated from each other using a 200ºC rated polyester enamel.

Induction Motor Reference Guide D - 20 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

INSULATION

The four basic insulation classes and their IEEE ratings are as Service Factor follows: Service Factor is a percentage multiplier applied to the CLASS HOT-SPOT TEMPERATURES nameplate horsepower to obtain the continuous overload capacity of the motor. A 105ºC B 130ºC Thus, a standard TEFC 10HP, Class F insulated motor could carry F 155ºC continuously 1.15 x 10HP or 11.5HP. H 180ºC It is important to remember that the value obtained by applying a service factor is valid only if usual service conditions, rated These four classes have been standardized by NEMA. voltage, 40ºC ambient, and rated frequency are maintained. Also, it should be noted that the resulting overload state will Most AC motors now use Class F insulation, but in the past, increase the temperature rise and may affect the motor’s Class B has been the most common. IEEE (Institute of Electrical efficiency, power factor and speed. and Engineering and Electronics Engineers) definitions for these four classes are as follows: Some motors are rated at their maximum temperature and therefore their service factor is given as 1.0. CLASS A: Materials or combinations of materials such as cotton, silk and paper when suitably impregnated or CLASS 20,000 HR. LIFE TEMPERATURE coated, or when immersed in a dielectric liquid such as oil. Other materials or combinations of materials A 105ºC may be included in this class if by experience or accepted tests the total system can be shown to be B 130ºC capable of operation at 105ºC. F 155ºC H 180ºC CLASS B: Materials or combinations of materials such as mica, glass fiber, polyesters and aramid laminates, etc., with suitable bonding substances. Other materials or WHERE DOES THIS TEMPERATURE COME FROM? combinations of materials, not necessarily inorganic, may be included in this class if by experience or Basically the temperature build-up comes from two accepted tests the total system can be shown to be fundamental components and an allowance factor. capable of operation at 130ºC. The three ingredients are: CLASS F: Materials or combinations of materials such as mica, 1. The ambient or room temperature. glass fiber, polyesters and aramid laminates, etc., 2. The temperature rise that occurs due to the heat generated with suitable bonding substances. Other materials or by the mechanical and electrical losses within the motor. combinations of materials, not necessarily inorganic, 3. Finally, due to the fact that the standardized motor may be included in this class if by experience or temperature measurement method (change in winding accepted tests the total system can be shown to resistance) measures the average temperature of the be capable of operation at 155ºC. All TECO- complete windings rather than the hottest spot (the point Westinghouse motors use Class F insulationas of highest thermal stress) an allowance factor called the standard. “hot spot allowance” must be added. CLASS H: Materials or combinations of materials such as silicone elastomer, mica, glass fiber, polyester’s and aramid laminates, etc., with suitable bonding substances such as appropriate silicone resins. Other materials or combinations of materials may be included in this class if by experience or accepted tests the total system can be shown to be capable of operation at 180ºC.

Induction Motor Reference Guide D - 21 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

INSULATION FIELD SERVICE

With referece to Class B insulated, Class B temperature rise, A. EXCESSIVE VIBRATION T-frame, 1.0 Service Factor, totally enclosed motor operating at a rated horsepower and rated voltage, these ingredients work out One of the most frequent complaints of motor troubles in the as follows: field is excessive vibration. The maximum vibration amplitudes CLASS B CLASS F often occur on the motor, and the user will conclude that the 1. Ambient Temperature 40ºC (104ºF) 40°C (104°F) motor is the source of the trouble. Sometimes this is correct, but 2. Temperature Rise (maximum allowable) 80ºC (176ºF) 105°C (221°F) in the majority of such instances, the cure does not involve the 3. Hot Spot Allowance 10ºC (50ºF) 10°C (50°F) motor. Total Temperature max (Hottest spot) 130ºC (266ºF) 155ºC (311ºF) Vibration is detrimental to all rotating equipment and should For service factored motors running at the service factor full be minimized. In recognition of this requirement, NEMA has load – i.e. 115% of rated load, the ingredients are as follows: adopted standards for “maximum allowable” vibration (NEMA MG 1-1998, 7.8) and the conditions under which it should be 1. Ambient Temperature 40ºC determined. TECO-Westinghouse’s commercial test limits for 2. Maximum Temperature Rise 90ºC vibration will not exceed the maximum specified by NEMA. 3. Hot Spot Allowance 10ºC It should be understood that a rotating motor or any rotating 140ºC machinery always has some vibration. The best balancing methods can never attain perfect balance. An idle machine Since 140ºC is 10ºC above the 130ºC Class B rating, you could exhibits no vibration. When the motor is energized the expect the motor’s thermal life to be cut in half if it runs vibration appears. continuously at the 15% overload conditions. Before the motor is removed and sent to a repair shop the user However, TECO-Westinghouse motors have Class F insulation should examine the entire machine and eliminate all possible systems as illustrated above. Therefore, the hottest allowable external contributing factors. temperature is 155ºC, well above the 140ºC temperature rise generated by the motor running at 1.15 service factor. A motor’s When a motor is applied to an installation it becomes part of a service factor capability should only be used when short term system consisting of one or more drivers (motors), the driven overloads are expected or when the motor is to be used in an equipment (one or more units), the foundations(s) and the environment where the ambient temperature contribution to mechanisms by which the components are interconnected, the total temperature is know to be less than 40ºC. (coupling, belts, etc.). Any one of these components can be the cause of, or contribute to, excessive system vibration. If motors are operated at rated load rather than service factor load, the temperature rise will be less than 80ºC so minimum The most common causes of “excessive vibration” are: normal life, or more, can be expected. 1. “Resonant” foundation or structure 2. Poor alignment (cold and/or hot) FIELD SERVICE 3. Loose “hold down bolts” securing the apparatus to its mounting Motor – Field Service 4. Unbalance in the motor, coupling(s), driven equipment (etc.)

All TECO-Westinghouse Motors have been designed for long In cases where excessive vibration is occurring, the reliable service. However, any man-made product manufactured recommended steps for isolating the trouble involves the in such large quantities and installed under such a variety of study of both amplitude and frequency of vibration as follows: conditions is likely to occasionally develop real or imaginary difficulties. 1 – RESONANT FOUNDATION

The more common user complaints can be combined under the Step 1: During operation, measure the actual vibration following seven headings. amplitudes with suitable instrumentation (such as an IRD Vibration Analyzer, Davey Vibrometer, etc.) at the A. Excessive vibration motor bearing housings in the vertical, horizontal, and B. Noisy axial directions. C. High Current D. Running Hot Step 2: Measure the vibration amplitude of the foundation E. Bearing Failed structure during operation to determine background F. Motor Burned Out vibration (if the foundation is shaking due to a resonant condition, or to vibration being fed in from an external source, this vibration will affect the magnitude of vibration which appears on the motor.

Induction Motor Reference Guide D - 22 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

FIELD SERVICE

If the vibration frequency of the foundation is low (less than 2 - POOR ALIGNMENT 50%) compared to the operating speed of the motor the movement of the foundation will tend to be in phase with Step 4: Check and correct system alignment both cold and the movement of the motor. Therefore, the total vibration hot (at system operating temperatures). For machines amplitude appearing on the motor will be the sum of the with operating speeds below 2000 RPM parallelism and motor vibration plus foundation vibration. angularity of the component shafts and couplings should be within .002 inches for machines with If the vibration frequency of the foundation is high (more than operating speed of 2000 RPM or higher the parallelism 150%) of the operating speed the movement of the foundation and angularity should be within .001 inches. will tend to be opposite (approaches 180ºC out of phase) in direction to the movement of the motor, and the vibration 3 - LOOSE HOLD DOWN BOLTS amplitude which appears on the motors will be the difference Step 5: If the natural frequency is well above the operating between the motor and foundation vibrations alone. (This frequency (150% of operating speed or more) and condition is extremely rare and is almost always due to a source not a harmonic, look elsewhere – check the system external to the motor and supporting structure.) components to make certain that they are properly shimmed, leveled and firmly tied down to the If the foundation frequency lies within the range of 50% and foundation structure. 150% of operating frequency the phase relationship between motor and foundation amplitudes becomes complex and a meaningful determination requires the use of a vibration meter 4 - UNBALANCE IN MOTOR with a filter to measure the amplitude and phase of each Step 6: While the motor coupling is broken, energize the motor frequency component. Such measurements and analysis are and measure the vibration amplitude as in Step 1. usually required only to identify an elusive source of external vibration. NOTE: Assuming that resonance is not present the uncoupled motor should exhibit vibration amplitudes within the limitation Step 3: Determine the natural frequency of vibration of the of NEMA standards. It is not uncommon for a motor to show a rotating system at rest. Vibration at the natural slight increase (less than 0.001 inch increase in vibration frequency can usually be induced by “bumping” the amplitude when it is sitting on a steel bedplate over what it motor at the same location and in the same plane demonstrated when it was checked for balance per NEMA Std. where the maximum vibration was measured in Step 1. MG-1-12.07 because steel is not as “dead” as the flexible pads specified by NEMA. However, the presence of vibration 1 2 If the natural frequency is close (in the range of /2 to /3) to amplitudes appreciably in excess (.001 inch or more) of these the operating frequency of a multiple of operating frequency standards indicates an unbalance attributable to the motor (called a harmonic) it must be changed to avoid resonance. This and/or the coupling half. can best be accomplished by reinforcing and stiffening the system foundation. Step 7: If the motor balance as demonstrated in Step 6 is satisfactory, the driven equipment and/or its supporting Vibration may occur in the supporting structure if there is structure are most probably the source of system vibration. insufficient mass built into the foundation. The foundation structure is usually concrete or steel or a combination of the two. B. EXCESSIVE NOISE Complaints of excessive noise in TECO-Westinghouse motors are A concrete structure may have its mass or weight increased rare. The important distinction which must be made is whether by adding to its size or thickness by building a frame around the reported noise indicates an abnormal condition requiring and pouring in more concrete. If this is not desirable another corrective action to preclude serious damage. The types of remedy is to add to the mass and at the same time improve the unusual noises which may indicate rapidly progressive damage resonance characteristics by pouring lead into a hole in the are: base. For instance, drill a hole in the concrete about 2” in diameter and 15” to 20” deep and fill with molten lead. The hold 1. “Squeals” and associated noises which indicate a loss of can be at a convenient location in the base and at an angle or clearance between rotating parts. Noises of this origin must vertical horizontal. be investigated and removed immediately. Typical causes are shifted blowers rubbing on air shields, shafts rubbing on bearing caps, etc.

Induction Motor Reference Guide D - 23 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

FIELD SERVICE

2. “Rumbles” and associated noises which indicate a bad Applied voltage higher than the nameplate rating will increase anti-friction bearing. Continued operation may result in the current in the motor appreciable until saturation of the complete failure and drop the rotor onto the stator. magnetic materials is reached at which point the current increases very rapidly and the motor will burn out. NEMA 3. Heavy magnetic noises, which indicate misconnection, short Standards state that induction motors “shall operate circuit, single phasing, etc. Continued operation may result successfully” with a voltage variation of ±10% of nameplate incomplete failure and drop the rotor onto the stator. voltage with rated frequency but that “operating performance within these voltage variations will not necessarily be in A difficult complaint to handle is one where an apparently accordance with the standards established for operation at perfectly good motor is unsatisfactory to one or more persons rated voltage”. The saturation point must be above rated because of the noise produced. In such instances it is wise to voltage plus 10% to provide acceptable performance. However, keep the following facts in mind when deciding on a course of it is entirely possible to experience saturation with say a 440 volt action: motor being operated on a distribution system supplying say 500 volts at the motor terminals. The saturation point is a 1. NEMA Standard MG-1-1998 paragraph 14.3.5 recognized function of the amount of magnetic steel used, the electrical that “Operation where low noise levels are required” is an characteristics of the steel, and the winding design. Any and/or unusual service condition; requiring consultation with all of these can be altered to provide optimum performance for manufacturer during negotiations. any specified voltage condition, but if the applied voltage is not precisely controlled, performance will vary from the motor. At 2. TECO-Westinghouse does not guarantee noise levels unless the point where actual voltage exceeds ±10% of rated voltage, they are specifically negotiated and incorporated into the performance will suffer markedly and very possible be entirely customer’s purchase order and are accepted by the unsatisfactory. Company. To repeat, high current can be the direct result of high 3. Noise apparently coming from a motor depends completely voltage. Nameplate full load current is stated for rated voltage on the generated noise level present in the area from other conditions and will vary with applied voltage until the magnetic sources. Consider how the kitchen refrigerator can be heard circuit becomes saturated, at which point current will increase at night when the house is quiet, but is rarely noticed during tremendously. Nameplate voltage at the motor terminals the day when normal house noises mask it. provides optimum performance.

4. Noise associated with a motor may seem to emanate from Higher than expected current may occur for another reason the motor, but may really come from “sounding boards” which is often overlooked. This is true with low speed motors which become excited by the forces which the motor and such as are frequently used for direct connection to low speed driven equipment place upon their foundations. Providing pumps. firmer foundations or isolation mounting devices often reduce noise from these sources. At the time when the system designer calculates the plant circuits, the motor starting equipment and the size of the wires 5. Cavities of all kinds, such as ventilator ducts to or from the to the motor he will often refer to standard tables to determine motor, small rooms, various shaped nooks and crannies, all the full load amperes of the motor. These standard tables apply may be excited like organ pipes by normal motor vibratory to motors of commonly used speeds down to 1200 RPM or forces, and may amplify normal motor noise. possible 900 RPM. The tables overlook the fact that a motor with speeds below these values usually has a very low power factor C. HIGH CURRENT which results in a considerably higher motor current. The true higher current figure will be stamped on the motor nameplate Unusually high currents drawn by an motor but by the time the motor is received by the user it is probable normally come to the user’s attention through the action of the that the starter and its circuits will have been installed on the overload protection associated with the starter. Commonly, this basis of the lower current shown in the standard tables. protection takes the form of calibrated “heaters” in the leads to the motor which respond to line amperes and operate bi- Wherever a slow speed drive is concerned be sure to check the metalic strips (when overheated) to open the line contactor and motor manufacturer for the accurate current value and ask for a shut down the motor. reply in writing so there will be no misunderstanding.

It is assumed that ambient conditions, heater ratings and horsepower demands of the driven equipment have all been reconfirmed and found to be satisfactory. Further investigation reveals that the motor is drawing current appreciable above the nameplate data at rated load as measured by a calibrated ammeter. Before condemning the motor make an accurate check of line voltage at the motor terminals.

Induction Motor Reference Guide D - 24 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

FIELD SERVICE

D. RUNNING HOT Check 5 – Check the bearings because defective bearings can increase the load on the motor and in small motors may First determine that the machine is actually running over become a large percentage of the load and result in overloading temperature. Just placing a hand on the machine is not and increased temperature. sufficient to actually decide a machine is exceeding allowable temperature rise. CONCLUSION: If all of the above check okay, the application could be wrong – too small a motor. It should be remembered that modern standard motors for any given horsepower rating are smaller and they use Class F E. BEARING FAILURES insulation. NEMA standards for Class F insulation allow a total temperature of 155ºC. Thermometers can be placed on the One of the most frequent troubles which occurs on motors in frame for measuring the temperature. the field is bearing malfunction or failure. Most bearing failures can be attributed to one of the following cases: The following checks can be made to determine the possible reasons for a machine running hot: 1. Inadequate, excessive or unsuitable lubrication 2. Misalignment Check 1 – Is the machine getting enough cool air? The 3. Overload amount of ventilation should be enough if; 4. Incorrect of faulty fitting 5. Damage during installation a. The shaft blower is present and clean. 6. Vibration while the bearing is not rotating b. The external blower motor is operating (in the case of 7. Corrosion external forced air cooling) 8. Passage of electric current through the bearing c. The shaft or external blower is rotating in the correct 9. Defective or incorrect bearings direction. d. There are no restrictions – air is getting in and out of the 1 – LUBRICATION machine. e. The air is not recirculating from the outlet into the inlet – (See also - Lubrication Guidelines page D-29) Check inlet temperature which should not be more than 5ºC above ambient. Perhaps the most common cause of bearing failures is improper f. The measurement of inlet and outlet temperature indicates lubrication. If the supply of lubricant is inadequate the bearing the temperature rise is normal. will run dry with consequent overheating and failure. If the g. The quantity of air is sufficient – check for missing air shield bearing overheats to the point where is loses clearance it will or improperly fitted air shield. The air shield should be about fail almost immediately. The bearing is usually burned and 1 /4” from the vanes and lined up with the vanes. severely damaged by this type of failure. If it does not lose h. The speed is incorrect – check motor speed with nameplate clearance the material in the races and rollers will be damaged. rating at full load. After a short time particles of material will flake away causing the bearing to become rough and noisy. Check 2 – Is the loading on the machine correct? To determine this: Only a small amount of lubricant is required in a bearing at any a. Check the duty cycle – is it continuous or is it being started one time, but a small amount of fresh lubricant must be fed and stopped too frequently. into the bearing to replenish that which is depleted by working b. Check supply voltage – incorrect voltage causes excessive and by oxidation. This action takes place in our motors which full load current and the losses go way up. are equipped with unshielded ball bearings. A clearance area c. Check supply frequency (NEMA allows ±5% from normal if around the edge of the inner bearing cap admits sufficient new normal voltage is maintained). grease while protecting the bearing against the addition of too d. Check for unbalanced phase-to-phase voltage. much grease. e. Check load voltage and current. Too much lubricant can be as destructive as too little. As soon Check 3 – Uncouple motor and take no load readings in each as a ball or roller bearing begins to rotate, any excess lubricant phase of the voltage, current and watts to determine if they are is pushed to the side of the ball or roller path. If the bearing normal. cannot purge itself in this manner, it will churn the lubricant generating high temperature and pressure. Rapid overheating Check 4 – (In places where a number of SCR drives are being of the bearing will result, often causing it lose clearance and/or used, check harmonic content of voltage source). SCR drives to reach temperature where the material loses its temper or the put harmonics back in the line and result in negative torques to lubricant itself burns. the machine which cause heating.

Induction Motor Reference Guide D - 25 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

FIELD SERVICE

When re-lubricating ball bearings, it is recommended that the There are specific recommendations published by NEMA and by motor be stopped and the outlet plug be removed. Add most belt drive manufacturers for minimum sheave diameters, lubricant with hand lever gun. minimum number of belts of a given size and type, etc., required to transmit standard horsepower at various speeds. The use of the proper type of lubricant is also very important. Also the belt drive manufacturers publish specific instruction on In the case of oil it must be viscous enough so that the film of how to adjust their drives for proper belt tension. lubricant will not break down under load, but at the same time not viscous enough to produce high frictional loads. Grease To evaluate whether or not a particular belt drive is suitable for must be still enough not to drain out of the bearing reservoir, use with a given motor the following information is required: but soft enough to settle against the bearing and be fed into it. 1. Manufacturer of the belt drive. As a general rule it is not advisable to intermix different 2. Diameter of both drive and driven sheaves. lubricants. The constituents of different lubricants may not be 3. Center distance between sheaves. compatible and intermixing may cause them to quickly break 4. Face width of the sheaves. down and lose their lubricating qualities. 5. Number and type of belts used (for standard V-belts, type A, B, C, D, or E; for super V-belts, 3V, 5V, 8V, etc). There are many varieties of lubricants available, most of them 6. Location of the drive sheave on the motor shaft. intended for a particular use. There is no such thing as an all 7. Direction of belt pull, relative to the motor. purpose lubricant. The motor manufacturer and/or lubricant 8. Nameplate data for the motor if this information is not manufacturer should be consulted whenever there is any already known. question as to whether a lubricant is suitable for a particular application. It is usually not possible to tell whether the belts were too tight after a failure has occurred. However, if there are other motors 2 - MISALIGNMENT with similar drives at the same site it might be worthwhile to check them. If the belts on the other motors are overly tight the It is obvious that a misalignment between the motor shaft and chances are they were on the failed motor also. the load shaft will bring about an early failure of the bearing. With each revolution this misalignment will impose heavy 4 – FAULTY FITS pressure followed by a relaxing of what pressure on many of the internal parts of the bearing. At operating speeds this change There are four important areas where the fit between the from plus to minus excessive pressure will occur so quickly and bearing and the other motor parts must be within prescribed frequently as to act like a riveting hammer on the surface of the limits to prevent faulty operation. balls and races. This will either crack the balls or race or at least flake off pieces from the surface. 1. The fit of the bearing inner race on the shaft. 2. The fit of the bearing outer race on the shaft. 3 - OVERLOAD 3. The internal clearances in the bearing itself between the balls and races. As a rule of thumb the life expectancy of a ball bearing is 4. The overall fit of the rotating assembly made up of the rotor, inversely proportional to the cube of the load. Therefore, an shaft, and bearings in the stationary assembly made up of overall increase in load can cause a relatively large decrease the frame and brackets. in bearing life. The material in the bearing races is actually deformed when the ball or roller passes over it. Eventually the 1. The bearing race which rotates relative to the load has a material will suffer fatigue failure, and pitting and flaking of tendency to spin if it is not restrained. The friction between material will occur in the ball track. the race and the shaft (or housing, as the case may be) can generate enough heat to cause the bearing to fail, some Heavy radial loads on a bearing may result from misalignment, times in a matter of hours. or from a belted application where the belts are too tight. Severe thrust loads can usually be traced to the equipment In the vast majority of motors the shaft rotates and the which the motor is driving. On belted applications the smaller inner race of the bearing is assembled on the shaft with an the diameter of the sheaves the greater will be the radial loads interference fit. On smaller frame sizes this fit will vary from imposed on the motor shaft and bearings. If multiple belts (such .001 inches to .0012 inches. On larger motors the fit can vary as V-belts) are used, the fewer the number of belts, the more from .003 inches to .0015 inches. There are some special they must be tightened to transmit a given horsepower without purpose motors where the fit may be as much as .0018 inches, slipping. but they will seldom be encountered.

Induction Motor Reference Guide D - 26 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

FIELD SERVICE

2. For ease of assembly the bearing race which is stationary 7 – CORROSION relative to the load is assembled into its housing (or onto the shaft, as the case may be) with a loose fit. It should not be Corrosion resulting from moisture getting into the bearings, or too loose however or this will tend to rotate at a slow rate in from prolonged storage in an area of high humidity will cause a its housing. On smaller frame sizes the fit of the race in its premature bearing failure. The rust will cause the balls and races housing can vary from .001 inches to .0013 inches. On to become rough and pitted. Most users will exercise care to some special purpose motors the fit may be as high as .0035 prevent water from getting into bearings while a motor is in inches. use. However, few of them take adequate measures to protect the bearings during prolongs storage of the motors. The motors 3. The internal clearance in a bearing is very important because should be kept warm and dry and the rotating element turned the loss of this clearance will cause a bearing to bind and fail over periodically to maintain film of lubricant on the bearing almost immediately. Usually the shaft and inner race of the surfaces. bearing will attain a higher temperature than the outer race and therefore will expand more. The outer race, however, 8 – ELECTRIC CURRENT may be somewhat constrained by its housing, causing the clearances in the bearing to be reduced from their original Bearing failures due to passage of electric current through value, when the motor reaches operating temperatures. the bearings or to defective or faulty material in the bearings are very rare. It will suffice to point out that such failures have To reduce the possibility of a bearing losing internal clearance occurred and the service of an experienced motor or bearing during operation the bearings used in TECO-Westinghouse engineer are usually required to diagnose this type of trouble industrial motors have larger internal clearances than do and to recommend remedial action. standard “off the shelf” bearing of the same type and size. Care should be exercised to insure that a bearing with the CONCLUSION: proper fit is used whenever a replacement is made in the field. The foregoing discussion demonstrates the importance of having the correct bearing, properly fitted and installed, and 4. Improper fits caused by incorrect dimensions, or out of correctly applied, to insure long trouble free operation. Each of round or distorted shaft and housing fits can all cause the causes of bearing malfunction can leave distinctive marks premature bearing and wear patterns which are quite revealing to the eye of the failures. experienced bearing engineer. Unfortunately, when a failure does occur, the bearing is usually so badly damaged that these 5 – INSTALLATION DAMAGE signs are obliterated. For this reason, examination of a bearing with incipient failure is usually much more revealing than Damage during installation is usually the result of carelessness examination of a bearing which has sustained severe damage. or ignorance. Such practices as pressing a bearing on a shaft by pushing on the outer race or allowing the bearing to take the thrust when a coupling is pressed on to a shaft can “brinell” the bearing races. Bearing and couplings are installed at the factory by preheating them and shrinking them into place, thereby reducing the possibility of installation damage. Preheating is usually done in a hot oil bath heated to a temperature somewhat below the flash point of oil.

6 – VIBRATION BRINELLING

If a motor equipped with ball or roller bearing is subjected to vibration over a prolonged period of time while it is not operating the movement can wear indention’s in the races where the balls or rollers are touching. This type of damage has occurred where motors are transported over long distances and the rotating assembly has not been restrained to prevent movement. One of the reasons for installing a pre-loading spring in one end of a motor is to prevent this type of damage.

Induction Motor Reference Guide D - 27 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

FIELD SERVICE USEFUL INFORMATION

F. MOTOR BURNED OUT • The front end of the motor is the end opposite the shaft extension. A motor winding might burn out for many reasons each having a more or less typical appearance as follows. • The location of the conduit box should always be referred to with reference to the front end of the motor. CASE 1: In a three phase motor a winding “burn out” due to a defect in workmanship or material would appear as a • Direction of rotation, i.e., clockwise (CW) or counter very localized burned spot in the failed winding and clockwise (CCW) is always when facing the front end of could be easily recognized. It might be a short circuit the motor. between the turns of wire in the coil or between the phases or even to the iron of the stator through • Starting torque is the turning effort that the motor can exert ruptured insulation. at standstill with voltage applied. It is expressed in percent of full load strength. CASE 2: On the other hand, when there is a complete “roast out” of the whole winding, all three phases of the • Inrush is a measure of current (or kVA) drawn from the line winding would be blackened uniformly. This would not at standstill when voltage is applied. Also called starting be due to a defect but it would be due to the failure of current or kVA, it usually runs 5 to 6 times full load the control system to shut off the power to an nameplate values for the conventional NEMA Design B or C overburdened motor. This overload might result from motors when full voltage is applied. some material being caught in the machine.

CASE 3: A single phase failure would be due to the loss of one phase from the power supply. This could be the result of:

• One fuse opened. • One contactor of the starter opened (burned off or poor contact). • One line of the incoming power line opened. • One connection in the conduit box opened.

Assuming that the motor has started and is properly running under load from a three phase circuit – if one of the above situations occurs the motor will then operate on only one phase. This phase will pull more current in order to try to carry the entire three phase load and in doing so will exceed its capacity.

Normally the overload protection in the starter should disconnect the motor but if it does not then the motor will continue to run and the working phase will become hotter and hotter until eventually the winding burns out.

Examination of the incoming circuitry will usually prove that one of the four reasons listed above can be blamed for the open circuit which caused the single phase failure. Obviously the motor manufacturer is exonerated.

Induction Motor Reference Guide D - 28 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

RE-LUBRICATION GUIDELINES

1. Frame 143T-256T: Double shielded and pre-lubricated ball-bearing motors without grease fittings and don’t need re-lubrication, except on Advantage Plus products which have re-greasable features.

2. Frames 280TS, 320 and larger: Motors having grease fittings and grease discharge devices at brackets. It is necessary to re-lubricate anti-friction bearing motors periodically, depending on size and type of service. See Table 1 to provide maximum bearing life. Excessive or too frequent lubrication may damage the motor.

* Motors are shipped with grease for initial running however it is a good idea to add grease when the motor is first put into service, follow table 1 for the recommended amount.

GREASE TYPE: Mobil Polyrex EM (unless otherwise specified).

GREASE QUANTITY: The amount of grease to add per replenishment is dependent on the size of the bearing. The following table (Table 1) will provide two different quantities; “G” will provide the quantity required to re-lubricate the bearing sufficiently for the interval time found in Table 2; while the second quantity “Full Qty” is the amount required to completely fill the bearing with new grease forcing the old grease out the exit tube. Adding the “Full Qty” amount is time consuming and requires ideal conditions; old dried up grease can potentially block the exit tube leading to over greased bearings and other undesirable results. For general applications the “G” quantity is sufficient, less time consuming and has lower risk of over greased bearings. The “G” amount is based on the formula G=DxBx0.005 and is widely used in our industry.

Table 1 2 SERIES 3 SERIES d D B G Full Quantity d D B G Full Quantity BEARING NUMBER BEARING NUMBER (mm) (mm) (mm) (grams) (grams) (mm) (mm) (mm) (grams) (grams) NU205/6205 25 52 15 4 15 NU305/6305 25 62 17 5 17 NU206/6206 30 62 16 5 15 NU306/6306 30 72 19 7 25 NU207/6207 35 72 17 6 15 NU307/6307 35 80 21 8 25 NU208/6208 40 80 18 7 20 NU308/6308 40 90 23 10 30 NU209/6209 45 85 19 8 25 NU309/6309 45 100 25 13 35 NU210/6210 50 90 20 9 30 NU310/6310 50 110 27 15 40 NU211/6211 55 100 21 11 35 NU311/6311 55 120 29 17 50 NU212/6212 60 110 22 12 40 NU312/6312 60 130 31 20 60 NU213/6213 65 120 23 14 50 NU313/6313 65 140 33 23 80 NU214/6214 70 125 24 15 50 NU314/6314 70 150 35 26 80 NU215/6215 75 130 25 16 60 NU315/6315 75 160 37 30 100 NU216/6216 80 140 26 18 60 NU316/6316 80 170 39 33 100 NU217/6217 85 150 28 21 80 NU317/6317 85 180 41 37 120 NU218/6218 90 160 30 24 80 NU318/6318 90 190 43 41 120 NU219/6219 95 170 32 27 90 NU319/6319 95 200 45 45 140 NU220/6220 100 180 34 31 100 NU320/6320 100 215 47 51 160 NU221/6221 105 190 36 34 110 NU321/6321 105 225 49 55 190 NU222/6222 110 200 38 38 120 NU322/6322 110 240 50 60 220 NU224/6224 120 215 40 43 120 NU324/6324 120 260 55 72 270 NU226/6226 130 230 40 46 140 NU326/6326 130 280 58 81 300

PROCEDURE: d = Bore (mm) D = OD (mm) • Clean grease zerk and grease gun tip. B = Width (mm) • Remove exit tube plug to allow old grease to drain. G = Grease Quantity (g) • Add grease slowly with motor running, adding amount determined in Table 1. • Allow one hour for old grease to run out, then reinstall exit tube plug. G = D * B * 0.005

* make sure grease gun is calibrated (one pump of gun should be approximately one gram of grease)

Induction Motor Reference Guide D - 29 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

RE-LUBRICATION GUIDELINES

INTERVALS: Lubrication intervals are dependent on temperature, environment, rotational speed and load conditions; therefore it is difficult to be precise about replenishment intervals. However, for common applications the periods shown in Table 2 may be used as a guide. For smaller bearings not listed in Table 2 use the maximum interval shown for rated speed.

Table 2 BEARING NUMBER 600 RPM 720 RPM 750 RPM 900 RPM 1000 RPM 1200 RPM 1500 RPM 1800 RPM 3000 RPM 3600 RPM 6210 62XX 2000 Hours 63XX 12 72XX 13 1000 Hours 73XX 14 15 720 Hours 16 17 2000 Hours 18 3000 Hours 20 22 1500 Hours 24 26 1000 Hours 28 2000 Hours 30 500 Hours 32 1500 Hours 34 36 2000 Hours 1000 Hours 38

BEARING NUMBER 600 RPM 720 RPM 750 RPM 900 RPM 1000 RPM 1200 RPM 1500 RPM 1800 RPM NU2XX NU214 NU3XX 15 2000 Hours 16 17 1500 Hours 18 3000 Hours 20 22 1000 Hours 24 2000 Hours 26 28 500 Hours 30 32 2000 Hours 34 1000 Hours 36 38 2000 Hours 40 1000 Hours 44 1000 Hours 48

BEARING NUMBER 600 RPM 720 RPM 750 RPM 900 RPM 1000 RPM 1200 RPM 1500 RPM 1800 RPM 222XX 22220 300 Hours 223XX 22 500 Hours 24 1000 Hours 26 28 30 300 Hours 32 500 Hours 34 36 500 Hours 38 300 Hours 40 44 300 Hours 48

Induction Motor Reference Guide D - 30 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

USEFUL FORMULAS

kW = HP x .746

HP x 5250 Torque in lb-ft = RPM

120 x Hz Motor Synchronous Speed in RPM = Number of Poles

HP x .746 Three Phase Full-Load Amp = Efficiency Power Factor 1.732 x E x x 100 100

HP (.746) Rated Motor kVA = Efficiency x Power Factor

HP (.746) (1.0 – Efficiency) kW Loss = Efficiency

Driven Machine RPM 2 Wk2 Referred to Motor Shaft Speed = Driven Machine Wk2 + Gear Wk2 at Motor Speed [ ( Motor RPM ) ]

.462 (Wk2 of Motor and Load) RPM2 Accelerating Time = Motor rated kW x 106 x per-unit Effective Accelerating Torque

kVA Inrush = Percent Inrush x rate kVA

Motor kVA Inrush Approximate Voltage Drop (%) = x Transformer Impedance (normally 5% to 7%) Transformer kVA

Stored Kinetic Energy in kW-sec = 2.31 x (total Wk2) x RPM2 x 10-7

Stored Kinetic Energy in kW Seconds Inertia Constant (H) in Seconds = HP (.746)

HP x 746 FL Amps = for 3 Phase Motors Eff. x PF x √3 x E

HP x 746 FL Amps = for Single Phase Motors Eff. x PF x E

E x I x √3 kVA Input = for 3 Phase Motors 1000

E x I kVA Input = for Single Phase Motors 1000

kW Input = kVA Input x P.F.

kW Input x Eff. HP Output = 746

Torque x RPM HP Output = 5250

kW Input Power Factor = kVA Input

Note: E is voltage, I is current, PF is power factor, Eff. is efficiency

Induction Motor Reference Guide D - 31 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 INDUCTION MOTOR REFERENCE GUIDE

Blank D - 32 For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 CONTACT INFORMATION

TWMI CANADA WIDE CONTACT INFORMATION

Have a question or comment for us? Maybe you need some technical or sales assistance? Feel free to call the location nearest you.

LOCATION CONTACT INFO LOCATION CONTACT INFO

CALGARY TECO-Westinghouse Motors (Canada) Inc. EDMONTON TECO-Westinghouse Motors (Canada) Inc. 9128 - 52 Street S.E. 18060 - 109 Avenue Calgary, Alberta T2C 5A9 Edmonton, Alberta T5S 2K2 24 HR Emergency Ph: (403) 473-5057 Phone: (780) 444-8933 Phone: (403) 640 -2063 Fax: (780) 486-4575 Fax: (403) 640-2075 24 HR Emergency Ph: (780) 994-8964 Toll Free: 800-661-4023 Fax Toll Free: 888-873-8964

CAMBRIDGE TECO-Westinghouse Motors (Canada) Inc. 1165 Franklin Blvd., Unit A - C LACHINE TECO-Westinghouse Motors (Canada) Inc. Cambridge, Ontario N1R 8E1 1810 - 55 Avenue 24 HR Emergency Ph: (519) 498-1806 Lachine, Quebec H8T 3J5 Phone: (519) 624-1616 Phone: 1-800-268-4770 Fax: (519) 624-1557 24 HR Emergency Pager: (514) 242-3179 Toll Free: 800-268-4770 Toll Free Ph: 1-800-268-4770 Toll Free Fax: 866-309-8964

TWMI CANADA 24 HOUR EMERGENCY PAGING SERVICE

Troubles happen at the worst of times. No worries, TWMI’s highly trained staff is here to help you out. If you have an emergency, feel free to contact us and let us help you to get back up and running as quick as possible.

Our technicians are on call 24 hours a day to provide service and solutions to your technical needs.

LOCATION EMERGENCY PAGING NUMBER

EDMONTON & NORTHERN ALBERTA SERVICE (780) 994-8964

CALGARY & SOUTHERN ALBERTA SERVICE (403) 473-5057

ONTARIO SERVICE (519) 498-1806

QUEBEC SERVICE (514) 242-3179

NOTE: (1) $150 After Hour Charge Monday - Sunday (2) $225 After Hour Charge All Statutory Holidays (3) Rates are based upon 2 hour Call-out

Contact Information Contact For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 NOTES

Notes For more information visit: www.tecowestinghouse.ca or call: 1-800-661-4023 WEST EAST 1-800-661-4023 1-800-268-4770