2006 Wastewater
Total Page:16
File Type:pdf, Size:1020Kb
CAPITAL PROJECTS Figures Effective as at 1 July 2006 WASTEWATER CAPEX DESCRIPTION CAPEX Value 2006 CAPEX Value Expenditure ID Contributing Area Asset Type/Location Problem Description/Location Problem Resolution ($) Adjusted ($) Date Reticulation, Treatment and Storage 1 1. Queenstown 2 3 4 Sunshine Bay 5 Queenstown Sunshine Bay PS Upgrade pumps (2x18.5kW) 83,702 87,217 2007 6 Queenstown Sunshine Bay PS Generator Generator (54 kVA) 60,078 62,601 2007 7 8 Lake Esplanade to Marine Parade PS 9 Queenstown Preliminary Design To incorporate the Sunshine Bay PS upgrade and associated reticulation upgrades through to the Loaded Hog (start of CBD Ringmain). 100,000 100,000 2006 10 Queenstown Whitbourn Pl to Aspen Grove Trunkmain 120511 to 122460 Upgrade from 150mm to 200mm 165,160 172,097 2007 11 Queenstown Sainsbury Rd to Lake Esplanade Trunkmain 122471 to 127607 Upgrade from 225mm to 375mm 220,790 230,063 2007 12 Queenstown Lake Esplanade to YHA Trunkmain 127608 to 127613 Upgrade from 300mm to 375mm 286,730 298,773 2007 13 Queenstown YHA to Rydges Trunkmain 127615 to 122713 Upgrade from 300mm to 450mm 90,180 93,968 2007 14 Queenstown Rydges to Brunswick Street Trunkmain 122711 to 120204 Upgrade from 300mm to 500mm 317,990 331,346 2007 15 Queenstown Brunswick Street to Loaded Hog Trunkmain 120205 to 300674 Upgrade from 375mm to 500mm 238,380 248,392 2007 16 17 Thompson Street to Lake Esplanade 18 Queenstown Thompson St to Lake Esplanade Trunkmain 300668 to 300669 Upgrade from 150mm to 200mm 33,350 34,751 2007 19 20 Post Office Relocation 21 Queenstown Relocation of line under the Post Office Council contribution to relocation cost Relocation 21,810 21,810 2006 22 23 Gorge Road 24 Queenstown Investigation Odour and capacity issues along Gorge Road Possible solutions include removing balance tank, pumping to Hal 8,052 8,390 2007 25 Queenstown Forward Design Gorge Rd upgrade 167,001 187,672 2009 26 Queenstown Sawmill Road to Hallenstein Street Trunkmain 122920 to 120610 Upgrade from 150mm to 225mm 99,585 115,716 2010 27 Queenstown Robins Rd to Boundary St Trunkmain 120638 to 120654 Upgrade from 225mm to 300mm 154,179 179,154 2010 28 Queenstown Industrial Place to Sawmill Road Trunkmain 126152 to 120603 Upgrade from 150mm to 200mm 324,333 376,870 2010 29 Queenstown Gorge Road to Hylton Place 122920 to 120634 Upgrade from 150mm to 250mm 216,333 251,376 2010 30 Queenstown Robins Rd to Camp St Trunkmain 120641 to 120059 Upgrade from 225/300mm to 375mm 577,548 671,102 2010 31 32 Frankton Track 33 Queenstown Cecil Road PS & RM New pumpstation and risingmain 2,600,000 2,600,000 2006 34 Queenstown Cecil Road PS & RM New pumpstation and risingmain 3,100,000 3,230,200 2007 35 36 Willow Place PS to Boyes Crescent 37 Queenstown Boyes Cr to Lake Ave Trunkmain 120915 Upgrade from 300mm to 450mm 102,970 102,970 2006 38 Queenstown Willow Place PS Upgrade station (electrics & variable speed drive) 30,605 30,605 2006 39 Queenstown Willow Place PS WW 21.3m3 total (increase of 7.8m3) 14,445 14,445 2006 40 Queenstown Willow Place PS RM 1100m, 300mm dia 468,013 468,013 2006 41 Queenstown Willow Place Standby Generator 38,741 38,741 2006 42 Queenstown Willow Place PS Emergency Storage 267m3 322,711 322,711 2006 43 Queenstown Willow Place PS Additional Land 400m2 120,000 120,000 2006 44 Queenstown Willow Place PS Upgrade station (electrics & variable speed drive) 30,605 31,891 2007 45 Queenstown Willow Place PS WW 21.3m3 total (increase of 7.8m3) 14,445 15,052 2007 46 Queenstown Willow Place PS RM 1100m, 300mm dia 468,013 487,670 2007 47 Queenstown Willow Place Standby Generator 38,741 40,368 2007 48 Queenstown Willow Place PS Emergency Storage 267m3 322,711 336,265 2007 49 Queenstown Willow Place PS Additional Land 400m2 120,000 125,040 2007 50 Queenstown Boyes Cr Trunkmain (ex Willow Place PS) 123280 Upgrade from 300mm to 375mm 164,090 164,090 2006 51 52 Kawarau Falls PS RM to Boyes Crescent 53 Queenstown Forward Design Kawarau Falls PS upgrade 10% of capital works estimate 118,496 118,496 2006 54 Queenstown Kawarau Falls PS RM 450m, 300mm 344,833 359,316 2007 55 Queenstown Kawarau Falls PS Currently has temporary pumping solution in place. Replace pumps (2x75kW) 130,061 135,523 2007 56 Queenstown Boyes Cr Trunkmain (ex Kawarau Falls PS) 120926 to 120913 Upgrade from 150mm to 450mm 116,253 121,136 2007 57 58 Bayview Rd to Willow Place PS 59 Queenstown Reticulation - Willow Place Campground to WP Upgrade from 150 mm to 200 mm 84,600 91,679 2008 60 Queenstown Forward Design Bayview Road PS upgrade 153,532 178,402 2010 61 Queenstown Bayview Road PS RM Replacement 1010m, 200mm 559,062 669,760 2011 62 Queenstown Willow Place West to Willow Place PS Trunkmain 120566 to 300331 Upgrade from 225mm to 375mm 68,652 82,246 2011 File: 2006 - 2011 Programme v4 (3 Wastewater Activity Management Plan Printed: 17/07/2006 Prepared By Queenstown Lakes District Council Status: Final CAPITAL PROJECTS Figures Effective as at 1 July 2006 WASTEWATER 63 Queenstown Intake to Willow Place West 121019 to 120988 Upgrade from 225mm to 300mm 669,474 802,034 2011 64 65 Riverside Road to Remarkables Park PS1 66 Queenstown Forward Design Riverside Road reticulation upgrade 130,736 156,623 2011 67 68 Remarkables Park PS1 69 Queenstown Forward Design Remarkables Park PS1 upgrade 60,664 63,212 2007 70 Queenstown Remarkables Park PS1 Upgrade pumps (2x37kW) 150,980 163,613 2008 71 Queenstown Remarkables Park PS1 RM 510m, 225mm dia 394,997 428,050 2008 72 73 Frankton Beach to Shotover Ponds 74 Queenstown Frankton Beach WW Conversion of existing wetwell. 44,813 44,813 2006 75 Queenstown Forward Design Frankton Beach PS upgrade 174,651 181,986 2007 76 Queenstown Frankton Beach PS 4 new pumps (4x155kW) 390,027 422,664 2008 77 Queenstown Frankton Beach Emergency Generator 1468 kVA 566,077 613,446 2008 78 Queenstown Frankton Beach to Shotover Ponds Stage 1 of Opus report. 1,800,000 1,800,000 2006 79 80 Shotover Ponds 81 Queenstown Treatment Facilities Carryover Infiltration Trials 57,420 57,420 2006 82 Queenstown Treatment Facilities Strategic Study 152,340 152,340 2006 83 Queenstown Treatment Facilities Strategic Study 198,180 206,504 2007 84 Queenstown Interim measures To increase capacity (PROJECT CURRENTLY UNDERWAY) Additional aerators 613,360 613,360 2006 85 Queenstown Security Fencing Replace and upgrade security arrangements 89,760 97,271 2008 86 Queenstown Telemetry / SCADA Upgrade telemetry and SCADA 239,800 259,866 2008 87 Queenstown Resource Consent Renewal process 51,480 51,480 2006 88 Queenstown Resource Consent Renewal process 51,480 53,642 2007 89 Queenstown Forward Design Shotover Ponds Plant Upgrade 551,720 620,010 2009 90 Queenstown Treatment - Queenstown Plant Upgrade 1,655,403 1,923,553 2010 91 Queenstown Treatment - Queenstown Plant Upgrade Activated Sludge System 3,310,076 3,965,491 2011 92 93 Queenstown - General 94 Queenstown Wastewater management policy To form part of QLDC's Subdivision and Engineering Standards 9,310 9,310 2006 95 Queenstown Investigation Telemetry / SCADA strategic study for the entire district. 47,110 49,089 2007 96 Queenstown Asset Management System Project scoping and design 11,638 11,638 2006 97 Queenstown Asset Management System Software and implementation 23,276 24,253 2007 98 Queenstown Asset Management System Software and implementation 23,276 25,224 2008 99 100 Queenstown - Other 101 Queenstown Asset Management Planning, Modelling, Calculations etc. 34,914 34,914 2006 102 Queenstown Asset Management Planning, Modelling, Calculations etc. 34,914 36,380 2007 103 Queenstown Asset Management Planning, Modelling, Calculations etc. 59,353 64,320 2008 104 Queenstown Asset Management Planning, Modelling, Calculations etc. 34,914 39,235 2009 105 Queenstown Asset Management Planning, Modelling, Calculations etc. 39,569 45,979 2010 106 Queenstown Asset Management Planning, Modelling, Calculations etc. 59,353 71,106 2011 107 Queenstown Renewals - Pipe TO BE DESIGNED & MANAGED BY THE NETWORK MGR Replace 375,795 407,242 2008 108 Queenstown Renewals - Pipe TO BE DESIGNED & MANAGED BY THE NETWORK MGR Replace 203,607 228,808 2009 109 Queenstown Renewals - Non-Pipe TO BE DESIGNED & MANAGED BY THE NETWORK MGR Replace 80,326 80,326 2006 110 Queenstown Renewals - Non-Pipe TO BE DESIGNED & MANAGED BY THE NETWORK MGR Replace 140,440 157,823 2009 111 Queenstown Renewals - Non-Pipe TO BE DESIGNED & MANAGED BY THE NETWORK MGR Replace 105,520 122,612 2010 112 Queenstown Renewals - Non-Pipe TO BE DESIGNED & MANAGED BY THE NETWORK MGR Replace 11,285 13,520 2011 113 Queenstown Reticulation - Queenstown Inflow and Infiltration Remedial Works 100,000 104,200 2007 114 Queenstown Reticulation - Queenstown Inflow and Infiltration Remedial Works 100,000 108,368 2008 115 116 TOTAL - QUEENSTOWN 25,544,817 27,667,639 117 118 2. Arrowtown 119 120 121 Boundary Street to Norfolk Street PS 122 Arrowtown Investigation Norfolk St RM pipe condition investigation 5,280 5,722 2008 123 Arrowtown Cornwall St to Norfolk St PS 126125 to 126010 Upgrade from 300mm to 375mm 148,390 154,622 2007 124 125 McDonnell Road PS 126 Arrowtown McDonnell Rd PS Generator Generator (47kVA) 63,280 68,575 2008 127 128 Bendemeer RM and Gravity Main to Shotover Ponds 129 Arrowtown Reticulation PROJECT CURRENTLY UNDERWAY 2,725,136 2,725,136 2006 130 Arrowtown Forward Design Bendemeer PS upgrade 13,672 15,887 2010 131 Arrowtown Bendemeer PS Add a third pump (1x57kW) 51,111 61,231 2011 132 Arrowtown Bendemeer PS Generator Generator 71,937 86,181 2011 133 134 Shotover Ponds 135 Arrowtown Forward Design Shotover Ponds Plant Upgrade 70,187 78,875 2009 File: 2006 - 2011 Programme v4 (3 Wastewater Activity Management Plan Printed: 17/07/2006 Prepared By Queenstown Lakes District Council Status: Final CAPITAL PROJECTS Figures Effective as at 1 July 2006 WASTEWATER 136 Arrowtown Treatment - Queenstown Plant Upgrade Activated Sludge System 210,593 244,706 2010 137 Arrowtown Treatment - Queenstown Plant Upgrade Activated Sludge System 421,094 504,473 2011 138 139 Arrowtown - General 140 Arrowtown Wastewater management policy To form part of QLDC's Subdivision and Engineering Standards 690 690 2006 141 Arrowtown Investigation Telemetry / SCADA strategic study for the entire district.