Fan Filter Unit Clean Air· Our Future FFU FFU Sound Pressure Level Curve (Octave Band)
Total Page:16
File Type:pdf, Size:1020Kb
Fan Filter Unit Clean Air· Our Future www.mayairgroup.com FFU FFU Sound Pressure Level Curve (Octave Band) 90 80 70 NC70 60 NC65 SPL dB(A) NC60 50 NC55 NC50 40 NC45 NC40 30 NC35 NC30 20 NC25 NC20 10 NC15 0 63 125 250 500 1000 2000 4000 8000 High Efficiency, Low noise level Frequency (Hz) FFU Octave Band Sound Pressure Level Curve Applications Uniformity of Air Distribution Ensure the deviation of face velocity is within ±10% Semiconductor Cleanroom Pharmaceutical & Laboratories 0.8 FFU Food Processing Industry 0.7 Product Features 0.6 Casing Construction 0.5 Material: Galvalume / stainless steel / aluminium V(m/s) 0.4 Optional Accessories 0.3 Air inlet prefilter, downstream diffuser, pressure gauge, pressure guage port for filter pressure drop monitoring, cleanliness monitoring port, DOP 0.2 testing port, air inlet collar, five-speed controller, humidity monitoring port, remote control, European plug and others 0.1 0.0 Uniform Air Flow Distribution Low Energy Consumption High efficiency blower Low Noise Level High total static pressure Air Velocity Distribution 3D Diagram Speed Controller Type: None / manual speed controller / small scale centralized speed controller 52 Fan Filter Unit Clean Air· Our Future www.mayairgroup.com FFU AC Motor Technical Data Power Input: 1 220V - 240V 50Hz Series F-22AL F-23AL F-24AM SERIESWxL (mm) F-22AL600x600/575x575 F-23AL 600x900/575x875F-24AL 600x1200/575x1175F-24AM WxL(mm)H (mm) 250 250 275 Air Velocity (m/s) 0.45 0.45 0.45 Static Pressure (Pa) 250 220 310 Power Consumption (W) 80 110 155 Noise Level dB(A) 50 51 53 Vibration Level (mm/s) 0.7 0.8 1.2 Series F-34AM F-34AH F-44AM1 F-44AH WxL (mm) 900x1200/875x1175 1200x1200/1175x1175 H (mm) 275 275 275 275 Air Velocity (m/s) 0.45 0.45 0.45 0.45 Static Pressure (Pa) 250 275 205 285 Power Consumption (W) 175 225 245 305 Noise Level dB(A) 53.5 53 55 53.5 Vibration Level (mm/s) 1.2 1.2 1.3 1.4 FFU EC Motor Technical Data Power Input: 1 200V - 277V 50Hz Series F-22EL F-23EL F-24EL F-24EM WxL(mm) 600x600/575x575 600x900/575x875 600x1200/575x1175 H(mm) 250 250 250 275 Air Velocity (m/s) 0.45 0.45 0.45 0.45 Static Pressure (Pa) 270 250 210 415 Power Consumption (W) 55 70 85 90 Noise Level dB(A) 49 50.5 51.5 51 Vibration Level (mm/s) 0.7 0.8 1.2 1.2 Series F-34EM F-34EH F-44EH WxL (mm) 900x1200/875x1175 1200x1200/1175x1175 H (mm) 275 275 275 Air Velocity (m/s) 0.45 0.45 0.45 Static Pressure (Pa) 320 430 360 Power Consumption (W) 120 125 180 Noise Level dB(A) 53 52.5 53.5 Vibration Level (mm/s) 1.2 1.2 1.4 Remarks: 1. Test point of noise is 1.5m below filter downstream. 2. Test point of air velocity is 0.15m below the filter. 3. FFU sizes can be customised upon request. 4. FFU power consumption in above tables is based on FFU initial performance. 53 Fan Filte r Unit Clean Air· Our Future FFU Performance Curves www.mayairgroup.com FFU AC Motor 300 160 300 160 140 140 250 250 Total Static Pressure (Pa) 120 Total Static Pressure (Pa) 120 200 200 100 Power (W) 100 Power (W) 150 180 150 180 60 60 100 100 40 40 50 50 20 20 0 0 0 0 500 1000 1500 2000 500 1000 1500 2000 FFU Air Flow (CMH) Air Flow (CMH) FFU Performence Curve (F-22AL) FFU Performence Curve (F-23AL) 400 320 400 320 350 280 350 280 Total Static Pressure (Pa) 300 240 Total Static Pressure (Pa) 300 240 250 200 Power (W) 250 200 Power (W) 200 160 200 160 150 120 150 120 100 80 100 80 50 40 50 40 0 0 0 0 500 1000 1500 2000 2500 3000 500 1000 1500 2000 2500 3000 Air Flow (CMH) Air Flow (CMH) FFU Performence Curve (F-24AM) FFU Performence Curve (F-34AM) Total Static Pressure - Air Flow curve Power - Air Flow curve HEPA/ULPA filter initial pressure drop - Air Flow curve (Thickness: 70mm) 54 Fan Filter Unit Clean Air· Our Future FFU Performance Curves www.mayairgroup.com FFU AC Motor 500 400 400 310 450 380 350 290 400 360 Total Static Pressure (Pa) Total Static Pressure (Pa) 300 270 350 340 250 Power (W) Power (W) 250 300 320 200 250 300 230 200 280 150 210 150 260 100 190 100 240 50 50 220 170 0 0 200 150 0 500 1000 1500 2000 2500 3000 3500 0 500 1000 1500 2000 2500 3000 Air Flow (CMH) Air Flow (CMH) FFU FFU Performence Curve (F-34AH) FFU Performence Curve (F-44AM1) 500 400 450 380 400 360 Total Static Pressure (Pa) 350 340 300 320 Power (W) 250 300 200 280 150 260 100 240 50 220 0 200 0 500 1000 1500 2000 2500 3000 3500 Air Flow (CMH) FFU Performence Curve (F-44AH) Total Static Pressure - Air Flow curve Power - Air Flow curve HEPA/ULPA filter initial pressure drop - Air Flow curve (Thickness: 70mm) 55 Fan Filter Unit Clean Air· Our Future FFU Performance Curves www.mayairgroup.com FFU EC Motor 300 160 300 160 140 140 250 250 Total Static Pressure (Pa) Total Static Pressure (Pa) 120 120 200 200 100 Power (W) 100 Power (W) 150 180 150 180 60 60 100 100 40 40 50 50 20 20 0 0 0 0 0 500 1000 1500 2000 0 500 1000 1500 2000 FFU Air Flow (CMH) Air Flow (CMH) FFU Performence Curve (F-22EL) FFU Performence Curve (F-23EL) 300 160 500 300 450 140 270 250 Total Static Pressure (Pa) 400 240 Total Static Pressure (Pa) 120 350 210 200 Power (W) 100 Power (W) 300 190 150 180 250 150 200 120 60 100 150 90 40 100 60 50 20 50 30 0 0 0 0 0 500 1000 1500 2000 0 500 1000 1500 2000 2500 3000 Air Flow (CMH) Air Flow (CMH) FFU Performence Curve (F-24EL) FFU Performence Curve (F-24EM) Total Static Pressure - Air Flow curve Power - Air Flow curve HEPA/ULPA filter initial pressure drop - Air Flow curve (Thickness: 70mm) 56 Fan Filter Unit Clean Air· Our Future FFU Performance Curves www.mayairgroup.com FFU EC Motor 500 300 500 400 450 270 450 360 Total Static Pressure (Pa) 400 320 Total Static Pressure (Pa) 400 240 350 210 350 280 Power (W) 300 190 Power (W) 300 240 250 150 250 200 200 120 200 160 150 90 150 120 100 60 100 80 50 3 0 50 40 0 0 0 0 0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000 3500 Air Flow (CMH) Air Flow (CMH) FFU FFU Performence Curve (F-34EM) FFU Performence Curve (F-34EH) 500 400 450 360 Total Static Pressure (Pa) 400 320 350 280 300 240 Power (W) 250 200 200 160 150 120 100 80 50 40 0 0 0 500 1000 1500 2000 2500 3000 3500 Air Flow (CMH) FFU Performence Curve (F-44EH) Total Static Pressure - Air Flow curve Power - Air Flow curve HEPA/ULPA filter initial pressure drop - Air Flow curve (Thickness: 70mm) 57 Fan Filter Unit Clean Air· Our Future AC FFU Group Control System www.mayairgroup.com Group Controller FFU Group Controller Power Supply Malfunction Indicator Indicator Multiple FFU Group Controller FFU FFU Group Controller Box Multiple FFU Touch Screen Control Product Features • Reliable FFU alternating current control system. • Group or single unit alarm indicator. • 3-stage or 5-stsage fan speed controller. Zone Controller • Over-current protection. • RS-485 communication mode can perform. remote control on the systems. Zone Controller 58 Fan Filter Unit Clean Air· Our Future AC FFU Group Control System www.mayairgroup.com MayAir FCS AC FFU Group Control System Product Features • Overcomes large-scale FFU alternating current control problem with comprehensive functions. • Multiple working areas/zones group control allows FFU HUB that are distributed at different floors or different locations HUB to be controlled according to working area/zone. It also allows FFU in same working area/zone but located in different RS-232 / 485 Converter room to be controlled according to group. • RS-485 communication module, integrated hardware installation, system low investment and easy installation. • Centralised control of FFU’s initiation, stop, fan speed and timing. Operation of the system is simple and energy saving. • Auto display of fan speed and FFU malfunction HUB indicator allow accrate positioning of FFU and diagnose the fault message. • Auto initialisation of FFU by group sequence prevents power supply disruption due to large-scale system FFU being initiated synchrnously at the same time. • 4-stage password control system allows a comprehensive and easy management of user. • User-friendly system incorporated with multiple languages such as English, simplified Chinese and traditional Chinese, suitable for users from different countries and regions. • FFU initiation utilizes low current, thus prevents power supply disruption. 59 Fan Filter Unit Clean Air· Our Future EC FFU Group Control System www.mayairgroup.com MayAir EFCS EC FFU Group Control System Product Features Repeater • Multiple working areas/zones group control allows FFU that are distributed at different floors or different locations to be controlled according to working area/zone. It also allows FFU in same working area/zone but located in different room to be controlled according to group.