North Dakota Firefighter's Association

Certification System

Fire Fighter

Certification Standard For the following specialties: ➢ Fire Fighter I

➢ Fire Fighter II

Based on: National Fire Protection Association (NFPA) 1001, Standard for fire Fighter Professional Qualifications, 2019 Standard

16 Fire fighter Life Safety Initiatives

1. Define and advocate the need for a cultural change within the fire service relating to safety; incorporating leadership, management, supervision, accountability, and personal responsibility. 2. Enhance the personal and organizational accountability for health and safety throughout the fire service. 3. Focus greater attention on the integration of with incident management at all levels including strategic, tactical, and planning responsibilities. 4. All fire fighters must be empowered to stop unsafe practices. 5. Develop and implement national standards for training, qualifications, and certification (including regular recertification) that are equally applicable to all fire fighters based on the duties they are expected to perform. 6. Develop and implement national medical and physical fitness standards that are equally applicable to all fire fighters, based on the duties they are expected to perform. 7. Create a national research agenda and data collection system that relates to the initiatives. 8. Utilize available technology wherever it can produce higher levels of health and safety. 9. Thoroughly investigate all fire fighter fatalities, injuries, and near misses. 10. Grant programs should support the implementation of safe practices and/or mandate safe practices as an eligibility requirement. 11. National standards for emergency response policies and procedures should be developed and championed. 12. National protocols for response to violent incidents should be developed and championed. 13. Fire fighters and their families must have access to counseling and psychological support. 14. Public education must receive more resources and be championed as a critical fire and life safety program. 15. Advocacy must be strengthened for the enforcement of codes and the installation of home fire sprinklers. 16. Safety must be a primary consideration in the design of apparatus and equipment.

The 16 initiatives address the 6 root causes of fire fighter injuries, close calls, and Line of Duty Deaths.

1. Ineffective policies and procedures 2. Ineffective decision making 3. Lack of preparedness 4. Ineffective leadership 5. Lack of personal responsibility 6. Extraordinary and unpredictable circumstances

- 2 -

NDFA Firefighter’s Certification Committee

The NDFA Certification Committee is a 10-member committee which consists of nine members from the North Dakota fire Service. The Committee members function as liaison between the fire service and the North Dakota Firefighter’s Association Executive Board. Members of the committee are:

➢ NDFA 1st Vice President ➢ State Fire Marshal ➢ (1) A member from the North Dakota Fire Chief’s Association o Will serve a two-year term ➢ (1) A member from the North Dakota Fire Prevention Association o Will serve a two-year term ➢ (1) A member from the North Dakota Instructor Society o Will serve a two-year term, ➢ (4) Four NDFA members at large o one member elected from each of the four training regions: NW, SW, NE, and SE (their terms will mirror the Trustee from their region) ➢ The NDFA Training Director o Represents as a non-voting member of the committee o Will serve as a compliance officer

- 3 -

Table of Contents

16 Firefighter Life Safety Initiatives……………………………………………………………. 2

NDFA Fighters Certification Committee.……………………………………………………… 3

Introduction…………………………….…………………………………………………. …….. 6

Certification Requirements………………….…………………………………………………. 7 Entrance Requirements Physical Fitness Requirements Emergency Medical Care Requirements (Fire Fighter I only)

Department Training……………….…………………………………………………………… 8 Written Objectives Manipulative Objectives Department Training Officers Department Training Records Department In-House Comprehensive Examination

Certification Examinations……………….……………………………………………………... 10 Written Examinations Manipulative Skills “Spot” Examination Prerequisites for Certification

Fire Fighter I Manipulative Skill Sheets.……………………………………………………….. 13 Personal Protective Clothing: Don, Use, and Doff – NFPA 4.1.2, 4.2.4, 4.3.1 Hoist Tools and Equipment – NFPA 4.3.20 Initiate Response to an Emergency – NFPA 4.2.1, 4.2.2 Transmit and Receive Radio Messages – NFPA 4.2.3 Respond on Apparatus – NFPA 4.3.2 Establish and Operate in Work Areas at Emergency Scenes – NFPA 4.3.3 Entry into Structure – NFPA 4.3.4 Exit a Hazardous Area – NFPA 4.3.5 Set Up, Mount, Ascend, Dismount, and Descend Ground Ladders – NFPA 4.3.6 Search and Rescue – NFPA 4.3.9 Overhaul a Fire Scene – NFPA 4.3.13 Operate an Air Monitoring Instrument – NFPA 4.3.21 Conserve Property – NFPA 4.3.14 Connect a Fire Department Pumper – NFPA 4.3.15 Extinguish Incipient Class A; Class B; Class C Fire with Portable Fire Extinguishers – NFPA 4.3.16 Establish Scene Lighting – NFPA 4.3.17 Turn Off Building Utilities – NFPA 4.3.18 Clean and Check Equipment – NFPA 4.5.1 Clean, Inspect, and Return Fire Hose to Service – NFPA 4.5.2

- 4 -

Table of Contents (continued)

Fire Fighter I Fireground Evolutions.………………………………………………………...... 49 Attack a Passenger Vehicle Fire – NFPA 4.3.7 Extinguish Fires in Exterior Class “A” Materials – NFPA 4.3.8 Attack an Interior Structure Fire – NFPA 4.3.10 Perform Ventilation – NFPA 4.3.12 Combat a Ground Cover Fire – NFPA 4.3.19

Fire Fighter II Manipulative Skill Sheets.……………………………………………………… 56 Utilize an Incident Management System – NFPA 5.1.2 Complete a Basic Incident Report – NFPA 5.2.1 Communicate the Need for Assistance – NFPA 5.2.2 Extinguish an Ignitable Liquid Fire – NFPA 5.3.1 Coordinate an Interior Attack – NFPA 5.3.2 Control a Flammable Fire – NFPA 5.3.3 Protect Evidence of Fire Cause and Origin – NFPA 5.3.4 Vehicle Extrication – NFPA 5.4.1 Assist Rescue Operation Teams – NFPA 5.4.2 Perform a Fire Safety Survey in a Private Dwelling – NFPA 5.5.1 Present Fire Safety Information to Station Visitors or Small Groups – NFPA 5.5.2 Prepare Pre-Incident Survey – NFPA 5.5.3 Maintain Power Plants, Power Tools, and Lighting Equipment – NFPA 5.5.4 Perform Annual Service Test on Fire Hose – NFPA 5.5.5

Appendix A – Training Records.………………………………………………………………... 71 Fire Fighter I – In-House Training Records Fire Fighter II – In-House Training Records

Appendix B – Examination Request Form .…………………………………………………….. 79

Appendix C – Candidate Acknowledgement Forms.…………………………………………... 81

- 5 -

Introduction

The world we live in is changing so fast, and the many phases of the fire service are becoming so technical and complex that fire service training must be utilized to its maximum potential. Any overlap, fragmentation, and lack of basic structure must be eliminated. Standardization is the natural complement and necessity.

The fire service in North Dakota, through a state certification program, can meet the needs of future growth and establish uniformity through certification. We will then have more effective and efficient utilization of resources to provide the best possible fire protection service for all the citizens throughout the state of North Dakota.

The following certification requirements are based on the objectives listed in the National Fire Protection Association (NFPA) 1001 Standard for Fire Fighter Professional Qualifications, as verified and adopted by the NDFA Firefighters Certification Committee.

Through these national standards and certification, fire fighters and fire departments have a tool to measure specific levels of skills, abilities, and knowledge. The NDFA Firefighters Certification Committee believe by participating in this certification program, fire fighters and fire departments will be better prepared to provide quality life safety and fire protection for their communities.

- 6 -

Certification Requirements

Entrance Requirements:

To certify within the NDFA Fire Fighter I and/or II program, departments and/or fire fighters must fulfill the following requirements:

1. Complete the department entrance requirements 2. Set up and maintain department records 3. Train on the required written and practical objectives 4. Pass a department “In-House” comprehensive examination 5. Meet any other training requirements/prerequisites as defined by the NDFA 6. Pass both the written and practical skills examination administered by the NDFA 7. Request certification of level desired

The NDFA acknowledges the importance of and need for entrance requirements as listed in the NFPA 1001, Standard on Fire Fighter Professional Qualifications. Many agencies and departments have existing policies, regulations, etc. already in place regarding these requirements. The handling of entrance requirements is a local matter outside the authority and jurisdiction of the NDFA. The NDFA will not check, test, evaluate, or determine how individual agencies meet these requirements. Some departments have found it necessary to waive any type of entrance requirements due to their own special needs. As a local decision, this is permitted. However, due to the amount of physical, mental, and emotional stress inherent in this profession, the NDFA strongly recommends careful evaluation before altering or doing away with any existing entrance requirements.

Physical Fitness Requirements:

The requirements listed in NFPA 1001, chapter 1.3.11 are:

1. Meet the minimum educational requirements established by the authority having jurisdiction 2. Meet the medical requirements of NFPA 1582, Standard on Comprehensive Occupational Medical Program for Fire Departments. 3. Physical fitness requirements for entry-level personnel shall be developed and validated by the authority having jurisdiction. Physical fitness requirements shall follow applicable Equal Employment Opportunity regulations and other legal requirements.

Emergency Medical Care Requirements:

The following additional training requirements must be met before certification at the Fire Fighter I level will be awarded by the NDFA.

1. Emergency Medical Care – Candidates for state certification at the Fire Fighter I level must hold a CPR certification and have received training in . First aid training should include infection control, bleeding control, and shock management. a. This training may be obtained through any organization that trains medical responders for CPR and first aid. A qualified instructor should teach these courses. Copies of the CPR cards (both sides) must be documented in the participant’s training record.

- 7 -

Department Training

The position of a fire fighter requires a high level of skill and knowledge. The training given to and received by fire fighter candidates should be of the highest quality and degree. All training received must meet the requirements of NFPA 1001, 2019 Edition, Chapter 4 and 5 along with the skills as approved by the NDFA contained within the North Dakota Standard. All training received must be documented and recorded on a training record (refer to Appendix A). All testing of this standard will be conducted following the policies and procedures of the NDFA.

Training for Fire Fighter I and Fire Fighter II is conducted at the department level. Training could also be received through a joint training agreement between departments on a regional level. Regardless of where the training is received, it must prepare the candidate to be a competent and effective fire fighter.

NFPA 1001, 2019 Edition, 1.2.6: Fire Fighter I and Fire Fighter II level individuals shall remain current with the general knowledge, skills, and JPRs addressed for each level or position of qualification.

The course material should be referenced to the following textbook to prepare the candidate to successfully pass the state certification examination.

Written Objective:

The written objectives for Fire Fighter I and Fire Fighter II are covered in the following text:

• Jones and Bartlett – Fundamentals of Fire Fighter Skills – 4th Edition

This textbook is available from various fire service bookstores. A current list of textbook sources is available by calling the NDFA at (701) 222-2799.

There are numerous methods departments have used to help prepare their personnel for the written examination. Considering the high level of skill and knowledge required, the NDFA recommends the candidate participates in a comprehensive class and receive instruction on both manipulative and written requirements.

Manipulative Objectives:

Each candidate must be trained and evaluated in the performance of all manipulative skills and fire ground evolutions for the level they will be testing. Each of the manipulative skills and evolution objectives shall be completed swiftly, safely and with competence as defined below:

• Swiftly – Each manipulative skill objective must be completed within the allotted time. • Safely – Each manipulative skill objective must be completed safely. Actions that could injure individual or damage equipment are unacceptable. Equipment should be checked prior to skill testing or training to see that it is safe and functional. • Competence – Each manipulative skill objective is performed in accordance with the North Dakota Standard. This includes performing the proper steps in sequence. Competence will be measured in accordance with the NDFA manipulative skill objectives.

- 8 -

Department Training (continued)

Department Training Officers:

For departments to enroll in the certification process, it is necessary for the department to assign training officers. It is recommended the department assign at least two personnel as training officers to coordinate and provide certification training.

Department training officers should be state certified at the level they are teaching. In addition, the NDFA strongly recommends training officers be state certified at the Instructor I level.

Department training officers will be responsible for certification training. Their primary responsibility will be to teach and evaluate department personnel on the manipulative skill and evolution requirements for each level of certification training with an “In-House” test.

Departments who do not have certified personnel to act as training officers for certification training should contact the NDFA Training Director at (701) 222-2799 for assistance in setting up and monitoring certification training.

Department Training Records:

Each candidate shall have a training record on file with the department that indicates whether he/she has trained on all manipulative skill objectives. This record shall be signed off or initialed by a department training officer. Training records must indicate the date, instructor, and total number of hours trained for each manipulative skill objective. Departments must use the one provided in Appendix A.

Department Comprehensive Examination:

At the completion of the department’s manipulative skills training, the department is required to hold an “In-House” comprehensive examination for the level being trained. This is a comprehensive test conducted by the department training officers or course instructors. This test is to ensure that skill mastery has been obtained from the beginning to the end of the training process, and to prepare participants for the state examination. Training officers may utilize other personnel to assist in administering the exam. However, all personnel assisting with the testing should be certified at the level they are testing.

In-House testers shall follow the Manipulative Skill sheets to provide for uniformity and fairness during the practical exam. It is recommended that candidates be given two attempts at any skill. No training, teaching, or coaching is allowed during this state test. If candidates fail on the second try, they have failed the evaluation and are required to go through additional training by the department trainer. After the evaluation, using the test to teach and train is recommended.

If manipulative skill weaknesses are evident, the department shall conduct additional training and hold a new department “In-House” comprehensive examination. Candidates that successfully pass the department’s skill and fire ground evolution tests will be allowed to participate in the state certification exam. Department training records must show all candidates have successfully passed the “In-House” examination.

- 9 -

Certification Examinations

After completion of the training process, the fire chief (or head of department) may request a written examination and manipulative test for certification using the “Examination Request” form in Appendix B. A testing fee may be charged at the time of certification. A separate application must be sent to the NDFA for each attempt. Examination Request forms must reach the NDFA no later than 30 days prior to the examination date. The entire examination process must be completed within one year of the first written exam attempt.

Certification Prerequisites:

When all requirements for certification have been met, candidates are eligible to be certified. The fire chief/head of department may apply to the NDFA for certification for those candidates who have successfully completed the certification training/testing process. Request for state certification will be submitted to the NDFA using the “Request for Certification” form provided in Appendix B. The names are then checked against the official state records to ensure each individual listed has met all requirements.

Those candidates who have met the requirements are issued a certificate and patch. These are sent to the fire chief/head of department for disbursement.

Prerequisites for Fire Fighter I Pro Board (NPQS) Certification:

o General Knowledge Requirements of NFPA 1001, section 4.1.1 ▪ Organization of the fire department ▪ Role of the Fire Fighter I in the organization ▪ Mission of the Fire Service ▪ Fire department’s standard operating procedures (SOPs) and rules and regulations as they apply to the Fire Fighter I ▪ Value of fire and life safety initiatives in support of the fire department mission and to reduce fire fighter line-of-duty injuries and fatalities ▪ Role of other agencies as they relate to the fire department ▪ Aspects of the fire department’s member assistance program ▪ Importance of physical fitness and a healthy lifestyle to the performance of the duties of a fire fighter ▪ Critical aspects of NFPA 1500, Standard on Fire Department Occupational Safety and Health Programs *These requirements can be fulfilled by attending the, Courage to Be Safe class offered by the NDFA. o ICS 100 o ICS 200 o NIMS 700 o Emergency Medical Care ▪ CPR certified ▪ Documented basic first aid training o Hazardous Materials Operations Pro Board (NPQS) Certification ▪ Candidates must successfully pass a written and manipulative “Spot Check” exam conducted by a Certification Tester. ▪ A written exam for Hazardous Materials Awareness (HMA) is a prerequisite for HMO. ▪ Refer to the NDFA Hazardous Materials Standard for further information.

- 10 -

Certification Examinations (continued)

o Structural-Based Live Fire Training ▪ Extinguishment of live fire assessed in an environment in compliance with 1403. This includes all physical tasks of associated JPRs such as stretching hose, advancing to the seat of the fire, operating the nozzle properly, and wearing the appropriate PPE.

Prerequisites for Fire Fighter II Pro Board (NPQS) Certification:

o Fire Fighter I Pro Board (NPQS) certification ▪ Legacy Fire Fighter I will be accepted as meeting the required prerequisite ▪ Any other Fire Fighter I certification must be preapproved by the NDFA o Auto Extrication ▪ Current auto extrication certification

Written Examination:

The written examination is a randomly generated 100-question test covering the written objectives for each level (Fire Fighter I and Fire Fighter II) of the standard; each having their own, respective tests. Both tests are multiple- choice. A minimum score of 70% is required to pass. Candidates failing the first attempt of the written exam are permitted to retest up to three times. After the third failed attempt, the candidate cannot test any earlier than three months/90 days from the date of the third attempt. Each subsequent exam attempts past four will be spaced out for a span of three months/90 days. A testing fee of $20.00 per retest attempt will be charged.

SAMPLE WRITTEN EXAMINATION QUESTIONS: The transfer of heat by the movement of air or liquid would be considered? a. Conduction c. Convection b. Radiation d. Direct-flame contact

What is a good, two-fire fighter method for breaking a tight coupling without a spanner wrench? a. Stiff-arm c. Knee-press b. Foot-tilt d. Coupling tilt

Manipulative Skills Examination:

The manipulative skills examination is split into two steps. The first step is a department records check conducted by the candidate’s department. The second step is a manipulative skill “Spot Check” examination conducted by certification testers appointed by the NDFA. Training records are required to be completed and turned in order to test the manipulative skills. Training records can be sent in to the NDFA Office prior to testing or brought to the test site. If training records are inadequate or absent, corrective action must be taken before proceeding to the next step. The training records must meet minimum requirements and are checked for the following:

1. Candidate has been trained in each manipulative skill for the level being evaluated 2. A department training officer has signed off each manipulative skill. 3. The total number of hours trained on each manipulative skill listed. 4. Each participant has passed a department “In-House” comprehensive examination

- 11 -

Certification Examinations (continued)

The manipulative skills and fire ground evolutions “Spot Check” examination is graded on a 100% pass/fail basis. The test is graded in the following three areas:

• Swiftly – Each manipulative skill objective must be completed within the allotted time. • Safely – Each manipulative skill objective must be completed safely. Actions that could injure individual or damage equipment are unacceptable. Equipment should be checked prior to skill testing or training to see that it is safe and functional. • Competence – Each manipulative skill objective is performed in accordance with the North Dakota Standard. This includes performing the proper steps in sequence. Competence will be measured in accordance with the NDFA manipulative skill objectives.

Candidates are “Spot Checked” on the manipulative skills/fire ground evolution of the level they are certifying in. No prior notification of the skills being tested will be given. No training, teaching, or coaching is allowed during this state test. The number of skills tested per level are as listed: • Fire Fighter I certification - Five (5) individual manipulative skills and one (1) Fire Ground Evolution • Fire Fighter II certification – Six (6) individual manipulative skill

Each individual skill has a skill sheet assigned that list the required competencies. These skills sheets identify how many competencies must be successfully completed to pass the skill station. It is highly recommended that candidates train using these skill sheets as the certification testers will evaluate test performance based off these competencies.

Individual Skills: Candidates will be given two attempts, if necessary, to perform each skill assigned at a specific test site. If a candidate fails a skill on the second attempt, they have failed the skills portion of the examination for that specific skill. The candidate will need to coordinate with the NDFA Office to schedule a later date to retest the failed skill and any other skills failed if any.

Candidates will be permitted to retest a failed skill attempt up to three times with a testing fee of $20.00 per retest. When retesting a failed skill, candidates will test the failed skill plus one additional skill from the section of the standard they failed. Candidates who have failed the third attempt of the manipulative skills examination have failed the certification process and must wait 30 days from the date of the failed third attempt.

- 12 -

FIRE FIGHTER I

MANIPULATIVE SKILL SHEETS

- 13 -

Fire Fighter I Skills Assessment Skill Sheet #1

PERSONAL PROTECTIVE CLOTHING: DON, USE, AND DOFF

JPR: NFPA 1001 – 2019 Edition, Sections 4.1.2, 4.2.4, and 4.3.1 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 5-1 thru 5-4, 5-8, 10-1, 10-7 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 3-1 thru 3-12, 18-1

Candidate Equipment Required: Full personal protective clothing and SCBA Evaluator Equipment Required: Stopwatch

Read to Candidate: There are three parts to this skill event. Each part will be evaluated.

In Part I you will be required to don personal protective clothing and Self-Contained Apparatus (SCBA) within two (2) minutes and 30 seconds. The method and exact sequence of donning the personal protective clothing and SCBA is not graded. When you have completed all donning procedures, raise your hands and I will stop your time. When completed, your SCBA and protective clothing must be appropriate for entry into a hazardous environment. Once you have raised your hands indicating you are done, do not touch your protective ensemble or SCBA until I have checked it. You will start this event wearing your event uniform and shoes.

In Part II you will be required to demonstrate use of self-contained breathing apparatus (SCBA) and recognize a SCBA emergency. You will be directed to enter a restricted passage where you will maneuver through while using the SCBA. Prior to entering the area, you must ensure all protective equipment and SCBA are properly donned and operational, including adequate air supply. You will enter the area as part of a team. While in the restricted passage, you must control your breathing and complete emergency procedures in the event of SCBA failure or air depletion. I will inform you if there is an emergency and what that emergency consists of.

In Part III you will be required to demonstrate doffing PPE, SCBA, replacing the SCBA air cylinder, and preparing the SCBA for reuse. Doffing PPE may be accomplished at the end of the manipulative test.

Part I of this skill station is a timed event. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD). You must complete the donning portion within the allotted time. Parts II & III are not timed.

P-Pass / F-Fail: PART I – Donning PPE/SCBA 1st Attempt 2nd Attempt

1. Dons boots, turnout pants, and suspenders. (Ensure: All fasteners are secured) 2. Dons protective hood. (Ensure: Hood is around neck and under coat) 3. Dons turnout coat. (Ensure: All fasteners [including collar] are secured) 4. Fully opens cylinder valve and checks gauges. 5. Places SCBA on back; fastens and tightens all straps. (Ensure: All fasteners are fastened and straps are tight. Airline must not be caught under chinstrap or a back-pack harness assembly strap) 6. Dons and checks facepiece for seal. 7. Pulls hood over facepiece straps. (Ensure: No skin is exposed around facepiece) 8. Dons helmet. (Ensure: Chin strap is secured) 9. Dons gloves. 10. Mounts regulator correctly to facepiece. 11. Dons PPE and SCBA within two (2) minutes thirty (30) seconds.

1st Attempt 2nd Attempt

End Time: ______- 14 -

P-Pass / F-Fail: PART II – Use of SCBA/Recognition of SCBA Emergency 1st Attempt 2nd Attempt

1. Prepares to enter area requiring SCBA use; checks air supply and regulator properly connected. (Ensure: Adequate air supply and regulator properly connected) 2. Controls breathing by taking normal breaths while using SCBA in restricted passage. 3. Recognizes SCBA emergency due to SCBA regulator failure or air depletion. 4. Notifies team members of emergency. 5. Checks regulator gauge reading. 6. Checks to ensure that cylinder valve is fully open. 7. Opens purge (bypass) valve slowly, takes a breath, and closes valve. 8. Always keeps facepiece on. 9. Calls Mayday. 10. Activates PASS device. 11. Exits hazardous area immediately with team members. 12. Notifies Command upon exiting the hazardous area. 13. Doffs SCBA and removed from service.

P-Pass / F-Fail: PART III – Doffing PPE, SCBA, Cylinder Replacement, and Returning SCBA to Service 1st Attempt 2nd Attempt

1. Removes and maintains control of SCBA. 2. Closes cylinder valve. 3. Bleeds air from system. 4. Replaces SCBA air cylinder. 5. Checks for damage and the need for cleaning (NOTE: this demonstration does not require actual cleaning, only check for need) 6. Returns SCBA to ready state. 7. Doffs gloves, boots, turnout coat and pants, suspenders, protective hood and prepare for reuse.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 15 -

Fire Fighter I Skills Assessment Skill Sheet #2

HOIST TOOLS AND EQUIPMENT

JPR: NFPA 1001 – 2019 Edition, Section 4.3.20 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 7-2 thru 7-13 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 9-5 thru 9-21

Candidate Equipment Required: Full personal protective clothing Evaluator Equipment Required: Utility rope (½ inch diameter), 100 feet of 1½” hose with nozzle, pick-head or flat-head axe, pike pole, roof ladder, and chain or vent saw

Read to Candidate: For this skill event you will be required to prepare tools and equipment to be hoisted to the roof of a building. I will select two tools or other fire service items for you to hoist. You may use any fire service knot you want to hoist the items as long as your choice is appropriate for the tool or equipment to be hoisted. If two ropes are used for hoisting (one to hoist and one for a tag line), you must use a safety knot on both ropes. You do not need a safety knot if you tie the knot in the middle of the rope (for simultaneous hoisting and a tag line). After you have prepared and hoisted the two selected items, I will ask you to tie one additional knot not used for hoisting. You must tie all knots while wearing structural firefighting gloves.

This is not a timed event; however, you should complete this event within a reasonable fireground time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD).

P-Pass / F-Fail: 1st Attempt 2nd Attempt Hoist TWO of the following: ______1. Hoists an axe. (Ensure: Head is down) ______2. Hoists a pike pole. (Ensure: Pike is up) ______3. Hoists a roof ladder. (Ensure: Roof hooks are up) ______4. Hoists an uncharged hose line. (Ensure: Line is folded over 2’-5’) ______5. Hoists a charged hose line. (Ensure: Rope is through nozzle bail so that is cannot open accidentally hoisting) ______6. Hoists a vent saw. (Ensure: Saw is securely held)

Tie ONE of the following knots not previously demonstrated: ______7. Connects two ropes of unequal diameter to make a single, longer line. (Ensure: Becket/Sheet Bend is used with a safety knot on each rope) ______8. Bowline. (Ensure: There is a safety knot) ______9. Clove hitch. (Ensure: There is a safety knot) ______10. Figure-8-on-a-bight. (Ensure: There is a safety knot)

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 16 -

Fire Fighter I Skills Assessment Skill Sheet #3

INITIATE RESPONSE TO AN EMERGECY

JPR: NFPA 1001 – 2019 Edition, Sections 4.2.1 and 4.2.2 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 2-1 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 4-1

Candidate Equipment Required: Station uniform clothing Evaluator Equipment Required: Telephone, notepad, and pen/pencil

Read to Candidate: For this skill event you will receive a call from a citizen to report an emergency. You MUST relay the information to the communications center so an emergency response can be initiated. You will be required to record the information appropriately, operate the communications equipment, and relay the information in an appropriate manner. I will serve as the citizen and the telecommunicator for the assessment.

To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD).

P-Pass / F-Fail: 1st Attempt 2nd Attempt Telephone Report: ______1. Answers fire department telephone. (Identifies: Fire department name and their name) ______2. Records type of incident being reported. ______3. Records address of incident. ______4. Requests caller’s name. and telephone number. ______5. Requests caller’s number. ______6. Relays information to communications center (dispatch agency). ______7. Provides communications center (dispatch agency) with accurate data.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 17 -

Fire Fighter I Skills Assessment Skill Sheet #4

TRANSMIT AND RECEIVE RADIO MESSAGES

JPR: NFPA 1001 – 2019 Edition, 4.2.3 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 2-2 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 4-3

Candidate Equipment Required: Station uniform clothing Evaluator Equipment Required: Fire department radio

Read to Candidate: For this skill event, you will be required to receive and transmit OR transmit and receive a message via fire department radio. You will be required to discriminate between routine and emergency traffic and act appropriately. I will serve as the receiver/transmitter for the skill.

To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Receive/Transmit OR Transmit/Receive message via FD radio. (Followed/Used: IMS communications model) ______2. Holds radio/microphone correctly and speaks clearly, calmly, and distinctly. ______3. Correctly operates equipment (e.g., channel selector, volume knob, squelch, etc.). ______4. Discriminates between routine and emergency traffic.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 18 -

Fire Fighter I Skills Assessment Skill Sheet #5

RESPOND ON APPARATUS

JPR: NFPA 1001 – 2019 Edition, Section 4.3.2 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 1-1 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 2-1, 2-2

Candidate Equipment Required: Full personal protective clothing Evaluator Equipment Required: Apparatus

Read to Candidate: For this skill event, you will be required to simulate an emergency response as a member of the apparatus’ crew. You are required to safely mount the apparatus, assume a seated position in the cab, and prepare to depart. When you are completely prepared to depart on the simulated emergency run, tell me so that I may check you. Once I have completed checking you, I will direct you to dismount the apparatus as part of the skill assessment. You will dismount as if you had arrived on-scene.

This is not a timed event; however, you should complete this event within a time considered reasonable for fireground operations. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Safely mounts apparatus using available handholds and steps. ______2. Assumes seated position and fastens seatbelt. ______3. Dons intercom headset or hearing protection (if provided). ______4. Checks for oncoming traffic before dismounting. ______5. Safely dismounts apparatus using available handholds and steps.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 19 -

Fire Fighter I Skills Assessment Skill Sheet #6

ESTABLISH AND OPERATE IN WORK AREAS AT EMERGENCY SCENES

JPR: NFPA 1001 – 2019 Edition, Section 4.3.3 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 1-4 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: None included; refer to pgs 51 and 52

Candidate Equipment Required: Full personal protective clothing Evaluator Equipment Required: Apparatus, traffic cones, and reflective traffic vest

Read to Candidate: For this skill event, you will be required to respond on this apparatus as a member of its crew to the simulated scene of a motor vehicle accident. Upon arrival, you will dismount the apparatus, verbally identify traffic , set out traffic control devices to establish a safe work area in which to conduct vehicle extrication operations, and then prepare to participate in those operations. I will act in the role of your company officer.

This is not a timed event, however; you should complete this event within a reasonable fireground time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a half of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Confirms order to operate in work area. ______2. Uses personal protective clothing. (Check to Ensure: All personal protective clothing is worn properly) ______3. Dons reflective traffic vest. ______4. Checks for on-coming traffic and then safely dismounts apparatus. ______5. Verbally identifies traffic hazards. ______6. Deploys traffic/scene control devices appropriately. ______7. Operates within the defined work area as ordered. ______8. Reports completion of assignment to company officer.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 20 -

Fire Fighter I Skills Assessment Skill Sheet #7A

FORCE ENTRY INTO STRUCTURE – DOOR

JPR: NFPA 1001 – 2019 Edition, Section 4.3.4 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 9-2 thru 9-5 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 10-1, 10-4, 10-8 thru 10-10

Candidate Equipment Required: Full personal protective clothing (including safety glasses or goggles) Evaluator Equipment Required: Door prop, rotary saw, chain saw, axe, pike pole, halligan bar, through-the-lock tools, and bolt cutters

Read to Candidate: For this skill event, you will be required to force entry into a building through a door. I will give you your specific assignment. The skill event assessment will begin after being given the assignment. There are two parts to this skill event.

In Part I, you must select appropriate tools for the assignment and transport them safely to the door to be forced.

In Part II, you must observe all safety precautions for forcing entry through a door and demonstrate proper use of tools when forcing entry through the door. When you indicate you have finished, the opening must be ready for entry. Do not skip steps or assume anything. Verbalize as you perform this skill assessment.

IF REQUIRED TO SIMULATE FORCIBLE ENTRY, READ THE FOLLOWING: To prevent actual property damage to the building, you will simulate the skill. Make certain to state verbally out loud each step as you simulate the actions (including applicable safety precautions), indicate proper use of tools, and when the opening is in safe condition and ready for entry.

This is not a timed event; however, you should complete this station within a reasonable fireground time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and half of the non-critical steps (steps in ITALICS) in both Part I and Part II.

P-Pass / F-Fail: PART I – Skill Demonstration 1st Attempt 2nd Attempt Select and Transport Tools 1. Confirms order to force entry through door. 2. Properly wears personal protective ensemble to include eye protection. 3. Selects appropriate tool(s) to force door. 4. Properly transports tool(s) to door to be forced.

P-Pass / F-Fail: PART II – Skill Demonstration 1st Attempt 2nd Attempt Force Entry: Door 5. Checks if door was unlocked. 6. Correctly uses tool(s) to force door. 7. Secures door in open position. 8. Observes all applicable safety precautions.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 21 -

Fire Fighter I Skills Assessment Skill Sheet #7B

FORCE ENTRY INTO STRUCTURE – WINDOW

JPR: NFPA 1001 – 2019 Edition, Section 4.3.4 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 9-5, 9-6 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 10-5 thru 10-7

Candidate Equipment Required: Full personal protective clothing (including safety glasses or goggles) Evaluator Equipment Required: Window prop, rotary saw, chain saw, axe, pike pole, and halligan bar

Read to Candidate: For this skill event, you will be required to force entry into a building through a window. I will give you your specific assignment. The skill event assessment will begin after being given the assignment. There are two parts to this skill event.

In Part I, you must select appropriate tools for the assignment and transport them safely to the window to be forced.

In Part II, you must observe all safety precautions for forcing entry through a window and demonstrate proper use of tools when forcing entry through the window. When you indicate you have finished, the opening must be ready for entry. Do not skip steps or assume anything. Verbalize as you perform this skill assessment.

IF REQUIRED TO SIMULATE FORCIBLE ENTRY, READ THE FOLLOWING: To prevent actual property damage to the building, you will simulate the skill. Make certain to state verbally out loud each step as you simulate the actions (including applicable safety precautions), indicate proper use of tools, and when the opening is in safe condition and ready for entry.

This is not a timed event; however, you should complete this station within a reasonable fireground time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and half of the non-critical steps (steps in ITALICS) in both Part I and Part II.

P-Pass / F-Fail: PART I – Skill Demonstration 1st Attempt 2nd Attempt Select and Transport Tools 1. Confirms order to force entry through window. 2. Properly wears personal protective ensemble to include eye protection. 3. Selects appropriate tool(s) to force window. 4. Properly transports tool(s) to window to be forced.

P-Pass / F-Fail: PART II – Skill Demonstration 1st Attempt 2nd Attempt Force Entry: Window 5. Checks if window was unlocked. 6. Correctly uses tool(s) to force window or remove glass. 7. If opened, secures windowpane in open position. 8. Observes all applicable safety precautions.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 22 -

Fire Fighter I Skills Assessment Skill Sheet #7C

FORCE ENTRY INTO STRUCTURE – WALL

JPR: NFPA 1001 – 2019 Edition, 4.3.4 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 9-7 thru 9-9 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 10-11 thru 10-13

Candidate Equipment Required: Full personal protective clothing (including safety glasses or goggles) Evaluator Equipment Required: Wall prop, rotary saw, chain saw, axe, pike pole, halligan bar, sledgehammer, and TNT tool

Read to Candidate: For this skill event, you will be required to force entry into a building through a wall. I will give you your specific assignment. The skill event assessment will begin after being given the assignment. There are two parts to this skill event.

In Part I, you must select appropriate tools for the assignment and transport them safely to the wall to be forced.

In Part II, you must observe all safety precautions for forcing entry through a wall and demonstrate proper use of tools when forcing entry through the wall. When you indicate you have finished, the opening must be ready for entry. Do not skip steps or assume anything. Verbalize as you perform this skill assessment.

IF REQUIRED TO SIMULATE FORCIBLE ENTRY, READ THE FOLLOWING: To prevent actual property damage to the building, you will simulate the skill. Make certain to state verbally out loud each step as you simulate the actions (including applicable safety precautions), indicate proper use of tools, and when the opening is in safe condition and ready for entry.

This is not a timed event; however, you should complete this station within a reasonable fireground time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and half of the non-critical steps (steps in ITALICS) in both Part I and Part II.

P-Pass / F-Fail: PART I – Skill Demonstration 1st Attempt 2nd Attempt Select and Transport Tools 1. Confirms order to force entry through wall. 2. Properly wears personal protective ensemble to include eye protection. 3. Selects appropriate tool(s) to force wall. 4. Properly transports tool(s) to wall to be forced.

P-Pass / F-Fail: PART II – Skill Demonstration 1st Attempt 2nd Attempt Force Entry: Wall 5. Identify call support members and successfully breaches wall. 6. Correctly uses tool(s) to breach wall without compromising structural integrity. 7. Observes all applicable safety precautions.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 23 -

Fire Fighter I Skills Assessment Skill Sheet #8

EXIT A HAZARDOUS AREA

JPR: NFPA 1001 – 2019 Edition, Section 4.3.5 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 10-8 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 18-2 thru 18-6

Candidate Equipment Required: Full personal protective clothing and SCBA Evaluator Equipment Required: Vision obscured conditions, charged hose line, and portable radio

Read to Candidate: For this skill event, you will be required to operate in a hazardous area where vision-obscured conditions exist. Prior to entering the vision- obscured conditions, you must verbalize your evaluation of the hazards and identify any potential safe havens. After you enter the vision- obscured conditions, you must locate and follow a guideline (hose line or wall) to the designated safe haven or outside the building. If a hose line is located, the team must determine the direction to the exit. You must conserve your air supply. If you deplete your air supply prior to exiting the hazardous area, you will fail this skill event. If you become separated both physically and verbally from your partner (your fault/your partners fault) in the hazardous area, you will fail this event. If the team becomes lost in the vision-obscured conditions, you will fail this skill event. I will assume you are lost if you are following the hose line in the wrong direction.

This is not a timed event; however, it must be completed on a single tank of air. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and at least half of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Confirms order to operate in hazardous area where vision-obscured conditions exist. ______2. Evaluates area for hazards and identifies a safe haven. ______3. Enters and operates as part of a team in a vision-obscured area. ______4. Maintains team integrity throughout the operation. ______5. Locates team and follows a guideline or wall to the exit. (Team DID NOT get lost) ______6. Conserves air supply. (Candidate DID NOT deplete air supply prior to exiting hazardous area) ______7. Notifies Command upon exiting the hazardous area.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 24 -

Fire Fighter I Skills Assessment Skill Sheet #9

SET UP, MOUNT, ASCEND, DISMOUNT, DESCEND GROUND LADDERS

JPR: NFPA 1001 – 2019 Edition, Section 4.3.6 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 8-2 thru 8-9 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 11-2 thru 11-20

Candidate Equipment Required: Full personal protective clothing Evaluator Equipment Required: Roof ladder, 24’ extension ladder, and/or 35’ extension ladder

Read to Candidate: For this skill event, you will operate individually OR as a member of a team demonstrating the ability to carry, place, and raise ladder(s). You must also judge correct angle for climbing, judge extension ladder height requirements, and mount/dismount the ladder based upon the assignment I give you. You will be required to assess overhead hazards, strength of structural support components, and any other existing hazards. You must verbalize conscious decisions, such as assessment of hazards, you are making so I know your actions are not coincidental. The skill event assessment will begin after I give you the assignment.

You will carry the ladder from the start point to a location appropriate to perform the operation required. You are required to observe all safety precautions when moving the ladder. You must use a fire service accepted ladder carry technique. You must use a fire service accepted method of raising the ladder to a position appropriate for the given assignment. You must use proper climbing technique and be properly secured to the ladder when required. You MUST advise me when the ladder is in position. After I assess placement, I will direct you to perform the operation for which the ladder was placed. After you perform the operation, return the ladder to its original start point. This skill event will be concluded when the ladder has been returned to its original start point.

This is not a timed event; however, you should complete this event within a reasonable fireground time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and half of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: 1st Attempt 2nd Attempt Carry, Raise, and Placement ______1. Confirms order to ladder structure. ______2. Selects appropriate length ladder for assignment. ______3. Carries the ladder correctly. ______4. Checks for hazards and overhead wires. ______5. Confirms that wall/roof will support the ladder. ______6. Raises ladder to vertical position safely. ______7. Extends ladder to proper height for assigned scenario. (Extension ladder only) ______8. Confirms all ladder fly locks were locked & tied off halyard. (Extension ladder only) ______9. Set ladder up safely to avoid obvious hazards, is stable, at correct climbing angle, tip location appropriate for assigned operation. ______10. Ascends, dismounts, mounts, and descends ladder properly based off assigned task. ______11. Uses proper climbing technique and secures self to ladder properly.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 25 -

Fire Fighter I Skills Assessment Skill Sheet #10

SEARCH AND RESCUE – FIRE FIGHTER WITH FUNCTIONING SCBA

JPR: NFPA 1001 – 2019 Edition, Section 4.3.9 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 10-3 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 12-1 thru 12-19, 18-7 thru 18-9

Candidate Equipment Required: Full personal protective clothing, SCBA, and PASS alarm Evaluator Equipment Required: Fire fighter with functioning SCBA, search line or hose, and vision-obscured area

Read to Candidate: For this skill event, you will be required to demonstrate skills for conducting a search and rescue within a structure in a vision-obscured environment. In this scenario, the victim is a fire fighter. You will need to determine if the victim’s SCBA is functioning or not functioning. You will then need to take action to rescue the victim accordingly.

You will operate as a member of a team and conduct a primary search. You will select a search pattern. You must maintain your chosen search pattern throughout the search. You must search until the victim is located or you have completed your search. If you locate a victim, you are required to remove the victim from the hazardous environment. You may use any method to remove the victim as long as it does not harm the victim and you are successful in removing the victim. You must maintain communication with your partner throughout the search.

This is not a timed event; however, you should complete this event within a reasonable fireground time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and half of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Assesses area to determine tenability for both rescuer and victim. ______2. Properly dons personal protective clothing and SCBA. ______3. Crawls low during search and rescue. ______4. Maintains selected search pattern and completely searches area. ______5. Communicates with partner and maintains contact (verbal and/or physical). ______6. Notifies Command upon locating victim. ______7. Rescues fire fighter with functioning respiratory protection. ______8. Operates as a member of a team. ______9. Team’s safety is not compromised. ______10. Notifies Command upon completing assignment.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 26 -

Fire Fighter I Skills Assessment Skill Sheet #11

SEARCH AND RESCUE – FIRE FIGHTER WITH NONFUNCTIONING SCBA

JPR: NFPA 1001 – 2019 Edition, Section 4.3.9 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 10-3 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 12-1 thru 12-19, 18-7 thru 18-11

Candidate Equipment Required: Full personal protective clothing, SCBA, and PASS alarm Evaluator Equipment Required: Fire fighter with nonfunctioning SCBA, search line or hose, vision-obscured area, and RIT pack

Read to Candidate: For this skill event, you will be required to demonstrate skills for conducting a search and rescue within a structure in a vision-obscured environment. In this scenario, the victim is a fire fighter. You will need to determine if the victim’s SCBA is functioning or not functioning. You will then need to take action to rescue the victim accordingly.

You will operate as a member of a team and conduct a primary search. You will select the search pattern. You must maintain your chosen search pattern throughout the search. You must search until the victim is located or you have completed your search. If you locate a victim, you are required to remove the victim from the hazardous environment. You may use any method to remove the victim as long as it does not harm the victim and you are successful in removing the victim. You must maintain communication with your partner throughout the search.

This is not a timed event; however, you should complete this event within a reasonable fireground time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Assesses area to determine tenability for both rescuer and victim. ______2. Properly dons personal protective clothing and SCBA. ______3. Crawls low during search and rescue. ______4. Maintains selected search pattern and completely searches area. ______5. Communicates with partner and maintains contact (verbal and/or physical). ______6. Notifies Command upon locating victim. ______7. Connects RIT air pack to victim’s SCBA or places RIT facepiece on victim. ______8. Rescues a fire fighter whose respiratory protection is not functioning. ______9. Operates as a member of a team. ______10. Team’s safety is not compromised. ______11. Notifies Command upon completing assignment.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 27 -

Fire Fighter I Skills Assessment Skill Sheet #12

SEARCH AND RESCUE – PERSON WITHOUT RESPIRATORY PROTECTION

JPR: NFPA 1001 – 2019 Edition, Section 4.3.9 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 10-3 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 12-1 thru 12-19

Candidate Equipment Required: Full personal protective clothing, SCBA, and PASS alarm Evaluator Equipment Required: Fire fighter with functioning SCBA, search line or hose, and vision-obscured area.

Read to Candidate: For this skill event, you will be required to demonstrate skills for conducting a search and rescue within a structure in a vision-obscured environment. In this scenario, the victim is an occupant. Once you locate the victim, take appropriate action to rescue the victim.

You will operate as a member of a team and conduct a primary search. You will select the search pattern. You must maintain your chosen search pattern throughout the search. You must search until the victim is located or you have completed your search. If you locate a victim, you are required to remove the victim from the hazardous environment. You may use any method to remove the victim as long as it does not harm the victim and you are successful in removing the victim. You must maintain communication with your partner throughout the search.

This is not a timed event; however, you should complete this event within a reasonable fireground time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Assesses area to determine tenability for both rescuer and victim. ______2. Properly dons personal protective clothing and SCBA. ______3. Crawls low during search and rescue. ______4. Maintains selected search pattern and completely searches area. ______5. Communicates with partner and maintains contact (verbal and/or physical). ______6. Notifies Command upon locating victim. ______7. Rescues a person who has no respiratory protection using appropriate carry/drag. ______8. Operates as a member of a team. ______9. Team’s safety is not compromised. ______10. Notifies Command upon completing assignment.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 28 -

Fire Fighter I Skills Assessment Skill Sheet #13

OVERHAUL A FIRE SCENE

JPR: NFPA 1001 – 2019 Edition, Section 4.3.13 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 15-1 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 19-14 thru 19-16

Candidate Equipment Required: Full personal protective clothing and SCBA Evaluator Equipment Required: Pumper, water source, hose and nozzle, axe, and pike pole

Read to Candidate: For this skill event, you will be required to demonstrate the overhaul of a fire scene so that all hidden fires are exposed and extinguished. Full personal protective clothing (including SCBA) must be worn during this evaluation. You are responsible for recognizing and preserving obvious signs of area of origin and/or arson. Void spaces should be exposed while maintaining structural integrity. Water must be applied for maximum effectiveness and the entire fire scene should be evaluated for complete extinguishment.

To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Confirms order to perform overhaul. ______2. Properly dons personal protective clothing and SCBA. ______3. Selects appropriate power and/or hand tools for overhaul tasks. ______4. Advances attack line to overhaul area. ______5. Removes flooring, ceiling, and wall components to expose void spaces without compromising structural integrity. ______6. Stands between overhaul work area and safe means of exit. ______7. Exposes and extinguishes hidden fires in walls, ceilings, and sub-floors spaces. ______8. Applies water for maximum effectiveness. ______9. Recognizes and preserves obvious signs of area of origin and arson. ______10. Evaluates fire scene for complete extinguishment. ______11. Notifies Command upon completing assigned overhaul.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 29 -

Fire Fighter I Skills Assessment Skill Sheet #14

OPERATE AN AIR MONITORING INSTRUMENT

JPR: NFPA 1001 – 2019 Edition, Section 4.3.21 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 10-2 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 19-14

Candidate Equipment Required: Full personal protective clothing and SCBA Evaluator Equipment Required: Air monitoring props

Read to Candidate: For this skill event, you will respond to a residence reporting their carbon monoxide alarm is sounding. As a member of a team, you will investigate the alarm. Using an air monitoring device, you will determine possible cause of the alarm and take appropriate action to mitigate the . You must wear all appropriate protective equipment while performing this task. During your investigation you must verbally inform Incident Command of your findings and follow their direction. I will act as Incident Command.

To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Confirms order with officer to perform air monitoring. ______2. Properly dons personal protective clothing and SCBA. ______3. Turns on air monitoring device and calibrates equipment according to manufacturer’s operating instructions. ______4. Systematically uses air monitoring equipment while investigating alarm. ______5. Reacts to alarms appropriately. ______6. Reports readings to Incident Command.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 30 -

Fire Fighter I Skills Assessment Skill Sheet #15

CONSERVE PROPERTY

JPR: NFPA 1001 – 2019 Edition, Section 4.3.14 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 15-2 thru 15-11 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 19-6 thru 19-13

Candidate Equipment Required: Full personal protective clothing and eye protection Evaluator Equipment Required: Furniture, salvage cover, mop, and squeegee

Read to Candidate: For this skill event, you will perform property conservation operations as assigned. During this skill station you must wear full personal protective clothing to include eye protection. SCBA is not required. I will direct you to deploy a salvage cover, either by yourself or as a member of a team, construct a water chute, or construct a catch-all. I will have you remove any “standing” water in the area while protecting the area I identify as the point of origin. After completing the property conservation actions, you are required to prepare the salvage cover(s) for reuse.

To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in ITALICS)

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Confirms order with officer to perform property conservation. ______2. Properly dons personal protective clothing and SCBA. ______3. Arranges furnishings in a clustered fashion. ______4. Conducts property conservation as directed by IC. • Deploys covering materials • Constructs water chute • Constructs catch-all ______5. Uses appropriate methods to remove water. ______6. Separates, removes, and relocates charred material to a safe location while protecting the area of origin for cause determination. ______7. Closes building openings to protect further damage. ______8. Operates as a member of a team. ______9. Notifies Command upon completing property conservation assignment. ______10. Prepares salvage covers for reuse (used roll OR fold).

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 31 -

Fire Fighter I Skills Assessment Skill Sheet #16

CONSERVE PROPERTY – STOP FLOW FROM SPRINKLER SYSTEM

JPR: NFPA 1001 – 2019 Edition, Section 4.3.14 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 14-4, 14-5 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 19-2 thru 19-5

Candidate Equipment Required: Full personal protective clothing and eye protection Evaluator Equipment Required: sprinkler valves, open sprinkler head connected to water supply, and sprinkler wedges/tongs

Read to Candidate: For this skill event, you are required to stop the flow from a sprinkler head and operate the main control valve (either the PIV or the OS&Y) to stop the flow in the sprinkler system.

To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in ITALICS)

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Confirms order with officer to stop flow from sprinkler system. ______2. Uses main control valve for sprinkler system to stop flow. ______3. Uses sprinkler wedges/stoppers to stop flow from sprinkler head. ______4. Notifies Command upon stopping flow from sprinkler system. ______5. Remains at sprinkler valve until ordered to leave.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 32 -

Fire Fighter I Skills Assessment Skill Sheet #17

CONNECT A FIRE DEPARTMENT PUMPER – TO A HYDRANT

JPR: NFPA 1001 – 2019 Edition, Section 4.3.15 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 13-1, 13-4, 13-5 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills:14-1 thru 14-4, 16-1, 16-3, 16-8

Candidate Equipment Required: Full personal protective clothing Evaluator Equipment Required: Pumper, fire hydrant, hydrant wrench, 2-1/2” (or larger) supply hose, and various adapters (double male, double female, reducers, etc.)

Read to Candidate: For this skill event, you will operate as a member of a team to connect a pumper to a residual water supply (hydrant). You are required to advance (at least 200 feet) the supply hose I identify from the pumper to the hydrant. You must “charge” the supply hose when I direct you to do so. The team is required to connect the supply hose to the pump. The assessment will be considered complete when the team advises me the assignment is complete. After completing the assignment, I will direct you to return the hydrant to a ready state. You will not be assessed on returning the supply hose to a ready state.

Prior to beginning the assessment, I will give you an opportunity to check to ensure everything is in a ready state.

This is not a timed event; however, you should complete this event within a reasonable fireground time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in ITALICS)

P-Pass / F-Fail: 1st Attempt 2nd Attempt Hand lay supply hose from hydrant: ______1. Confirms order to make hydrant connection using a reverse lay. ______2. Properly dons personal protective clothing and SCBA. ______3. Hand lays supply hose from pumper to hydrant. ______4. Connects supply hose to hydrant. ______5. Connects supply hose to pumper intake. ______6. Supply hose laid and connection to hydrant completed within a “reasonable” time frame. ______7. Fully opens and closes hydrant at appropriate times. ______8. Connectors are tight with water flow unobstructed. ______9. Operates as a member of a team. ______10. Returns hydrant to ready state.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 33 -

Fire Fighter I Skills Assessment Skill Sheet #18

CONNECT A FIRE DEPARTMENT PUMPER – TO A STATIC WATER SUPPLY

JPR: NFPA 1001 – 2019 Edition, Section 4.3.15 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 13-2, 13-3 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills:14-6, 14-7

Candidate Equipment Required: Full personal protective clothing Evaluator Equipment Required: Pumper, portable water tanks, hard suction supply hose, intake devices, and 1-1/2” or 1-3/4” hose

Read to Candidate: For this skill event, you will operate as a member of a team to establish a water supply from a static water supply (portable water tanks). The team is required to deploy portable water tanks, hose for drafting, hose for transferring water from a portable water tank to the portable water tank to be used for the drafting operation, and appropriate devices required for the transfer and drafting operation. The team is not required to fill the portable water tanks or operate the pump. The assessment will be complete when the team advises me the assignment has been completed. You will not be assessed on returning the equipment to a ready state.

Prior to beginning the assessment, I will give you an opportunity to check to ensure everything is in a ready state.

This is not a timed event; however, you should complete this event within a reasonable fireground time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: 1st Attempt 2nd Attempt Set up for Static Water Source: ______1. Confirms order to set-up for static water source using a portable tank. ______2. Properly dons personal protective clothing and SCBA. ______3. Properly deploys portable water tank. ______4. Properly deploys equipment necessary to transfer water between portable water tanks (when portable water tanks are used as the static water source). ______5. Connects strainer to hard suction. ______6. Connects hard suction hose to pumper. ______7. Properly positions hard hose in static water source for drafting operation. ______8. Completes set-up for static water source within a “reasonable” time frame. ______9. Connectors are tight with water flow unobstructed. ______10. Operates as a member of a team.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 34 -

Fire Fighter I Skills Assessment Skill Sheet #19

EXTINGUISH INCIPIENT CLASS A; CLASS B; AND CLASS C FIRES WITH PORTABLE FIRE EXTINGUISHERS

JPR: NFPA 1001 – 2019 Edition, Section 4.3.16 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 6-1 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 7-2 thru 7-9

Candidate Equipment Required: Full personal protective clothing and SCBA Evaluator Equipment Required: Class A/B/C fire extinguishers, class A combustibles and burn pan, and propane simulator (for class B and C fires)

Read to Candidate: For this skill event, you will be required to completely extinguish an incipient Class “A”, Class “B”, or Class “C” fire. You will be required to select the correct portable extinguisher for the type and size of fire. Once you have selected the correct extinguisher, you are required to carry the extinguisher safely to a position where you can safely attack the fire. Once you have carried the extinguisher to the position where you intend to attack the fire from, you must safely approach the fire, operate the extinguisher, and extinguish the fire. After the fire is extinguished, you must retreat to a safe position.

This is not a timed event; however, you should complete this event within a reasonable fireground time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Confirms order to extinguish incipient fire with fire extinguisher. ______2. Properly dons personal protective clothing and SCBA. ______3. Selects appropriate extinguisher based on size and type of fire. ______4. Checks to ensure the extinguisher is charged and ready for use. ______5. Carries extinguisher properly. ______6. Approaches the fire properly. ______7. Properly operates portable extinguisher (PASS method). ______8. Completely extinguishes fire. ______9. Backs away from fire with extinguisher ready to operate. ______10. Notifies Command that incipient fire has been extinguished.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 35 -

Fire Fighter I Skills Assessment Skill Sheet #20

ESTABLISH SCENE LIGHTING

JPR: NFPA 1001 – 2019 Edition, Section 4.3.17 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 1-2, 1-3 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 19-1

Candidate Equipment Required: Full personal protective clothing (SCBA if conditions require) Evaluator Equipment Required: Department lighting and power equipment

Read to Candidate: For this skill event, you will be required to establish scene lighting while operating as a member of a team. You will operate department power supply and lighting equipment, deploy cords and connectors, reset ground-fault interrupter (GFI) devices, and locate lights for best effect. You are required to wear appropriate personal protective equipment. If it is necessary to enter a hazardous atmosphere to accomplish your assignment, you are required to use SCBA. If you will be performing tasks around the exterior and are not wearing the SCBA face mask, you are required to wear eye protection.

This is not a timed event; however, you should complete this event within a reasonable fireground time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and half of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Confirms order to establish scene lighting. ______2. Properly dons personal protective clothing and SCBA. ______3. Carries lighting equipment properly. ______4. Deploys cords and connectors properly as needed. ______5. Operates department power supply (generator or invertor). ______6. Properly reset Ground Fault Interrupter (GFI) as needed. ______7. Ensures scene is adequately and safely illuminated. ______8. Operates as a member of a team. ______9. Notifies Command upon completing horizontal ventilation.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 36 -

Fire Fighter I Skills Assessment Skill Sheet #21

TURN OFF BUILDING UTILITIES

JPR: NFPA 1001 – 2019 Edition, Section 4.3.18 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 14-6 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 17-12, 17-13

Candidate Equipment Required: Full personal protective clothing and SCBA Evaluator Equipment Required: Gas meter prop and electric panel prop

Read to Candidate: For this skill event, you will be required to turn off building utilities to include electric and gas utilities for the building. You must use appropriate tools and safety precautions when performing each task. You must tell me of any (simulated) hazards associated with each utility that could pose a safety hazard. NOTE: If you control a utility in an “unsafe” manner, it will constitute a failure of this skill event.

To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Confirms order to control utilities. ______2. Properly dons personal protective clothing (SCBA must be worn when controlling gas). ______3. Identifies electrical utility control device. ______4. Assesses for potential hazards prior to controlling electricity. ______5. Operates electrical utility control device (Pulling the electric meter constitutes failure). ______6. Identifies gas utility control device. ______7. Assesses for potential hazards prior to controlling gas. ______8. Operates gas utility control device. ______9. Notifies Command after utilities are controlled.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 37 -

Fire Fighter I Skills Assessment Skill Sheet #22

CLEAN AND CHECK – LADDERS

JPR: NFPA 1001 – 2019 Edition, Section 4.5.1 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 8-1 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 11-1

Candidate Equipment Required: Station uniform clothing and gloves Evaluator Equipment Required: Cleaning supplies and ladders

Read to Candidate: For this skill event, you will be required to clean, check, and maintain ladders. You will be provided with all the necessary cleaning supplies to accomplish your task. You must verbalize to me all the components you are checking.

To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Selects correct tools and equipment for cleaning, checking, and maintaining ladders. ______2. Checks all components for missing parts or damage. ______3. Checks halyard & pulleys (if applicable). ______4. Checks for loose rungs. ______5. Cleans ladders with soapy water & scrub brush. ______6. Checks need for lubrication of movable parts (if applicable). ______7. Returns ladders to a state of readiness. ______8. All cleaning and checking done according to manufacturer’s guidelines. ______9. Completes records and reporting procedures as required.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 38 -

Fire Fighter I Skills Assessment Skill Sheet #23

CLEAN AND CHECK – VENTILATION EQUIPMENT

JPR: NFPA 1001 – 2019 Edition, 4.5.1 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 9-1, 21-1 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 8-1, 13-13, 13-14

Candidate Equipment Required: Station uniform clothing, gloves, and eye protection Evaluator Equipment Required: Cleaning supplies, axe, pike pole, ventilation saw, and positive pressure fan

Read to Candidate: For this skill event, you will be required to clean, check, and maintain ventilation equipment. You will be provided with all the necessary cleaning supplies to accomplish your task. You must verbalize to me all the components you are checking.

To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Selects correct tools/equipment for cleaning, checking, and maintaining ventilation equipment. ______2. Examines ventilation equipment for damage and missing components. ______3. Checks oil and gasoline supply for power tools and equipment. ______4. Checks cord and switch on electrical power tools and equipment. ______5. Checks chain on ventilation saw. ______6. Returns ventilation equipment to a state of readiness. ______7. All cleaning and checking done according to manufacturer’s guidelines. ______8. Completes records and reporting procedures as required.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 39 -

Fire Fighter I Skills Assessment Skill Sheet #24

CLEAN AND CHECK – SCBA

JPR: NFPA 1001 – 2019 Edition, 4.5.1 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 5-5 thru 5-8 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 3-9 thru 3-14

Candidate Equipment Required: Station uniform and gloves Evaluator Equipment Required: Cleaning supplies and SCBA

Read to Candidate: For this skill event, you will be required to clean and check SCBA. There are two parts to this skill event.

In Part I, you will be required to perform an inspection on SCBA. You will be provided with all the necessary equipment and supplies necessary to accomplish your task. You must verbalize to me all the components that you are inspecting.

In Part II, you will be required to demonstrate cleaning a SCBA. You will be provided with all the necessary equipment and supplies necessary to accomplish your task. You must verbalize to me all the components that you are checking.

This is not a timed event; however, you should complete this event within a reasonable time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and half of the non-critical steps (steps in ITALICS) for both Part I (inspection) and Part II (cleaning).

P-Pass / F-Fail: PART I – Skill Demonstration 1st Attempt 2nd Attempt Inspection 1. Identifies all components of SCBA are present. 2. Inspects all SCBA components for cleanliness and damage. 3. Verifies cylinder has current date. 4. Verifies cylinder is at least 90% OR GREATER filled. 5. Opens cylinder slowly while listening for audible air leaks. If leaking, resolves leak(s) or removes from service. 6. Checks gauges and/or indicators. 7. Checks all PASS functions. 8. Dons facepiece and checks for leaks. 9. Checks regulator by taking several normal breaths. 10. Operates bypass/purge valve. 11. Turns cylinder off, bled pressure from system, and listens for low-air alarm. 12. Inspection done according to manufacturer’s guidelines. 13. Returns all components and straps to a state of readiness.

- 40 -

P-Pass / F-Fail: PART II – Skill Demonstration 1st Attempt 2nd Attempt Cleaning 14. Selects correct supplies for cleaning SCBA. 15. Cleans SCBA with soapy water & scrub brush. 16. After cleaning, inspects all components for damage. 17. Returns all components and straps to a state of readiness. 18. All cleaning done according to manufacturer’s guidelines. 19. Completes records and reporting procedures as required by department.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 41 -

Fire Fighter I Skills Assessment Skill Sheet #25

CLEAN AND CHECK – ROPES

JPR: NFPA 1001 – 2019 Edition, Section 4.5.1 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 7-1 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 9-1 thru 9-3

Candidate Equipment Required: Station uniform clothing Evaluator Equipment Required: Life safety rope and cleaning supplies

Read to Candidate: For this skill event, you will be required to clean and inspect a life safety rope. You will be provided with all the necessary cleaning supplies to accomplish your task. You must verbalize to me all the components you are checking.

This is not a timed event; however, you should complete this event within a reasonable fireground time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Selects correct tools/equipment for cleaning, checking, and maintaining ropes. ______2. Examines rope surface for cuts, stains, and fraying. ______3. Examines inner components by feeling for thinness or bunching. ______4. Cleans rope with clear water using rope washer, front loading washer, or by hand. ______5. Allows rope to air dry completely. ______6. Returns rope to storage or a state of readiness. ______7. All cleaning and checking done according to manufacturer’s guidelines. ______8. Completes records and reporting procedures as required.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 42 -

Fire Fighter I Skills Assessment Skill Sheet #26

CLEAN AND CHECK – SALVAGE EQUIPMENT

JPR: NFPA 1001 – 2019 Edition, 4.5.1 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 15-12 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: None included; refer to pg 752

Candidate Equipment Required: Station uniform clothing and gloves Evaluator Equipment Required: Cleaning supplies and tarp

Read to Candidate: For this skill event, you will be required to clean and check salvage equipment. You will be provided with all the necessary cleaning supplies to accomplish your task. You must verbalize to me all the components you are checking.

To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: 1st Attempt 2nd Attempt Salvage Tarps: ______1. Selects correct tools/equipment for cleaning, checking, and maintaining salvage equipment. ______2. Examines salvage cover for damage, dirt, and debris. ______3. Cleans salvage cover with soapy water & scrub brush. ______4. Allows salvage cover to air dry completely. ______6. Returns salvage equipment to a state of readiness. ______7. All cleaning and checking done according to manufacturer’s guidelines. ______8. Completes records and reporting procedures as required.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 43 -

Fire Fighter I Skills Assessment Skill Sheet #27

CLEAN AND CHECK – HAND TOOLS

JPR: NFPA 1001 – 2019 Edition, Section 4.5.1 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 9-1 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 8-1

Candidate Equipment Required: Station uniform clothing, gloves, and eye protection Evaluator Equipment Required: Cleaning supplies and hand tools (axe, pike pole, wrenches, sledgehammer, etc.)

Read to Candidate: For this skill event, you will be required to clean and check various hand tools. You will be provided with all the necessary cleaning supplies to accomplish your task. You must verbalize to me all the components you are checking.

This is not a timed event. However, you should complete this event within a reasonable fireground time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and half of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Selects correct tools/equipment for cleaning, checking, and maintaining hand tools. ______2. Examines handles for damage. (e.g., cracks, splits, splinters, etc.) ______3. Examines cutting or working components for damage. ______4. Examines striking surface for damage. ______5. Checks tool head for tightness. ______6. Cleans hand tools with soapy water & scrub brush. ______7. Applies coat of boiled linseed oil to handle (if appropriate). ______8. Applies coat of machine oil on metal surface (if appropriate). ______9. Returns hand tools to a state of readiness. ______10. All cleaning, checking, and maintenance done according to manufacturer’s guidelines. ______11. Completes records and reporting procedures as required.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 44 -

Fire Fighter I Skills Assessment Skill Sheet #28

CLEAN, INSPECT, AND RETURN FIRE HOSE TO SERVICE – RELOAD APPARATUS

JPR: NFPA 1001 – 2019 Edition, Section 4.5.2 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 12-2, 12-5 thru12-9 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 15-1, 15-7, 15-8, 16-5, 16-7, 16-13, 16-15, 16-17

Candidate Equipment Required: Station uniform clothing, gloves, and eye protection Evaluator Equipment Required: Cleaning supplies, attack hose, supply hose, fire apparatus with hose bed or hose bed prop

Read to Candidate: For this skill event, you will be required to inspect, clean, and return fire hose to service. There are two parts to this skill event.

In Part I, you will demonstrate how to inspect and clean fire hose. If you determine the hose is damaged/defective, you must mark it and remove it from service. You will verbalize to me as you inspect and identify any damage/defect that you find. After inspecting the fire hose, you will demonstrate cleaning and drying it.

In Part II, you will demonstrate loading fire hose. I will direct you to load a supply hose. This will be performed as part of a team. The supply hose must be loaded so it is in a ready state for service.

To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: PART I – Skill Demonstration 1st Attempt 2nd Attempt Inspection 1. Checks male coupling for damaged threads and out-of-round (threaded coupling only). 2. Checks female coupling for freedom of movement and out-of-round (threaded coupling only). 3. Checks for damaged or broken lugs (Storz coupling only). 4. Examines outer hose jacket for physical damage. 5. Checks gaskets for defects, flexibility, and presence (replace if necessary). 6. Identifies defective hose, marks, and removes from service. 7. Completes records and reporting procedures as per department policy.

Cleaning 8. Cleans hose with soapy water and scrub brush OR operated hose washing equipment. 9. Dries hose with hose drying equipment (if applicable). 10. Hose cleaning and drying done according to manufacturer’s recommendations.

- 45 -

P-Pass / F-Fail: PART II – Skill Demonstration 1st Attempt 2nd Attempt Return Hose to Service: Reload Hose 11. Returns hose to service by reloading onto apparatus hose bed or hose bed prop. 12. Reloads hose properly to a state of readiness.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 46 -

Fire Fighter I Skills Assessment Skill Sheet #29

CLEAN, INSPECT, AND RETURN FIRE HOSE TO SERVICE – ROLL HOSE

JPR: NFPA 1001 – 2019 Edition, Section 4.5.2 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 12-2 thru 12-4 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 15-1, 15-7 thru 15-12

Candidate Equipment Required: Station uniform clothing Evaluator Equipment Required: Cleaning supplies, attack hose, and supply hose

Read to Candidate: For this skill event, you will be required to inspect, clean, and return fire hose to service. There are two parts to this skill event.

In Part I, you will demonstrate how to inspect and clean fire hose. If you determine the hose is damaged/defective, you must mark it and remove it from service. You will verbalize to me as you inspect and identify any damage/defect that you find. After inspecting the fire hose, you will demonstrate cleaning and drying it.

In Part II, you will demonstrate rolling fire hose. I will direct you to roll a length (50’ or 100’) of fire hose. I will identify what type of hose roll to demonstrate. The fire hose must be rolled so it is in a ready state for service.

To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: PART I – Skill Demonstration 1st Attempt 2nd Attempt Inspection 1. Checks male coupling for damaged threads and out-of-round (threaded coupling only). 2. Checks female coupling for freedom of movement and out-of-round (threaded coupling only). 3. Checks for damaged or broken lugs (Storz coupling only). 4. Examines outer hose jacket for physical damage. 5. Checks gaskets for defects, flexibility, and presence (replace if necessary). 6. Identifies defective hose, marks, and removes from service. 7. Completes records and reporting procedures as per department policy.

Cleaning 8. Cleans hose with soapy water and scrub brush OR operated hose washing equipment. 9. Dries hose with hose drying equipment (if applicable). 10. Hose cleaning and drying done according to manufacturer’s recommendations.

- 47 -

P-Pass / F-Fail: PART II – Skill Demonstration 1st Attempt 2nd Attempt Return Hose to Service: Roll Hose 11. Returns hose to service by rolling. 12. Hose rolled properly for placement on hose rack or on apparatus.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 48 -

FIRE FIGHTER I

FIREGROUND EVOLUTIONS

- 49 -

Fire Fighter I Skills Assessment FGE Sheet #1

ATTACK A PASSENGER VEHICLE FIRE

JPR: NFPA 1001 – 2019 Edition, Section 4.3.7 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 14-7 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 17-11

Candidate Equipment Required: Full personal protective clothing, SCBA, and PASS alarm Evaluator Equipment Required: Car fire prop, pumper, water source, halligan bar, flat head axe, 1½” minimum diameter hose and nozzle (primary and back-up)

Read to Candidate: For this skill event, you will be required to extinguish or control a passenger vehicle fire as a member of a team. You will use appropriate protective equipment, firefighting tools, and extinguishing agents. You will be required to assess all hazards, utilize safety precautions, identify and control all fuel leaks, expose hidden fires, provide protection for team members from flash fire while advancing an attack line, applying water with maximum effectiveness, and extinguishing the fire.

To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Confirms order to extinguish car fire. ______2. Properly dons personal protective clothing and SCBA. ______3. Identifies automobile fuel type (verbalizes). ______4. Assesses for and controls fuel leaks (verbalizes). ______5. Operates nozzle correctly (open, close, adjust flow pattern). ______6. Applies water for maximum effect while maintaining flash fire protection. ______7. Advances attack line properly. ______8. Searches for, exposes, and extinguishes hidden fires. ______9. Withdraws attack line properly. ______10. Operates effectively as a member of a team. ______11. Notifies Command upon completing assignment.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 50 -

Fire Fighter I Skills Assessment FGE Sheet #2

EXTINGUISH FIRES IN EXTERIOR CLASS “A” MATERIALS

JPR: NFPA 1001 – 2019 Edition, Section 4.3.8 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 14-8 thru 14-10 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 17-10

Candidate Equipment Required: Full personal protective clothing, SCBA, and PASS alarm Evaluator Equipment Required: Class A material, pumper, water source, hose and nozzle (primary and back-up)

Read to Candidate: For this skill event, you will extinguish a Class A fire as a member of a team. You will be required to wear personal protective clothing and SCBA, use firefighting hand tools, and operate an attack line. You must approach the fire correctly and then perform necessary overhaul and extinguishment procedures. You should indicate to me any exposures needing to be addressed and/or hazards associated with the fire.

To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Confirms order to extinguish Class A fire. ______2. Properly dons personal protective clothing and SCBA. ______3. Recognizes hazards from material’s configuration (verbalizes). ______4. Operates hose lines and other water application devices. ______5. Evaluates and modifies water application for maximum penetration. ______6. Breaks up material with hand tools and/or water streams. ______7. Searches for and exposes hidden fires. ______8. Evaluates for complete extinguishment. ______9. Assesses burn patterns for origin determination. ______10. Notifies Command upon completing assignment.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 51 -

Fire Fighter I Skills Assessment FGE Sheet #3

ATTACK AN INTERIOR STRUCTURE FIRE

JPR: NFPA 1001 – 2019 Edition, Section 4.3.10 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 13-6 thru 13-20, 14-1 thru 14-3 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 17-1 thru 17-9

Candidate Equipment Required: Full personal protective clothing, SCBA, and PASS alarm Evaluator Equipment Required: Live fire burn facility, pumper, water source, 1½” minimum diameter hose and nozzle, ladder, hose tool (strap or rope), forcible entry tools, and thermal imaging camera

Read to Candidate: For this skill event, you will attack an interior structure fire operating as a member of a team. There are two parts to this skill event.

In Part I, you will be assigned to attack either a fire above grade, at grade, or below grade. You must use appropriate protective equipment including SCBA and firefighting tools. The skill assessment will begin once I give you the assignment. You will be required to assess all hazards, utilize safety precautions, and use appropriate attack line advancement techniques for either a charged or uncharged hose line. You must determine and use an appropriate fire attack technique to control and extinguish the fire. Prior to entry, you must verbalize your hazard assessment, safety precautions you will practice, and fire attack technique you will use (direct, indirect, or combination). Once the fire is under control, you will be required to verbalize how you would locate fires in void spaces, and how you would expose and extinguish those fires.

In Part II, after you have extinguished the interior fire, I will direct you to either replace a “simulated” burst section of hose or extend your hose to a specified length.

This is not a timed event; however, you should complete this event within a reasonable fireground time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in ITALICS) in both Part I and Part II.

P-Pass / F-Fail: PART I – Skill Demonstration 1st Attempt 2nd Attempt Interior Fire Attack 1. Confirms order to perform offensive fire attack (above grade, at grade, or below grade fire [for fires above grade confirm use of stairs or ladder for attack]). 2. Properly dons personal protective clothing and SCBA. 3. Sizes up fire for hazards. 4. Advances hose line (charged or uncharged) to fire. 5. Operates nozzle in a manner appropriate for the situation. 6. Uses appropriate fire attack technique (direct, indirect, or combination). 7. Operates nozzle to prevent water hammer. 8. Locates, exposes, and extinguishes fires in void spaces (walls and subfloors). 9. Operates as a member of a team. 10. Team integrity was not compromised during operation. 11. Notifies Command upon controlling fire.

- 52 -

P-Pass / F-Fail: PART II – Skill Demonstration 1st Attempt 2nd Attempt Replace Burst Hose/Extend Hose 11. Properly uncouples/couples hose connections. 12. Carries hose to location of burst hose line. (only for burst hose) 13. Replaces burst section of hose. (only for burst hose) 14. Carries hose to location of hose line needing extension. (only for hose extension) 15. Properly connects hose extension. (only for hose extension)

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 53 -

Fire Fighter I Skills Assessment FGE Sheet #4

PERFORM VENTILATION

JPR: NFPA 1001 – 2019 Edition, Sections 4.3.11 and 4.3.12 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 11-1 thru 11-4 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 13-1 thru 13-12

Candidate Equipment Required: Full personal protective clothing, SCBA, and PASS alarm Evaluator Equipment Required: Roof/Window prop, pumper, water source, hose and nozzle, positive pressure fan, ladder, axe or pike pole, and chainsaw.

Read to Candidate: For this skill event you will be required to perform ventilation on a smoke-filled structure while operating as a member of a team. You will be required to wear appropriate personal protective equipment during this evaluation. You will ventilate the structure using the assigned ventilation technique (horizontal or vertical). Given the assigned technique, you will select the proper tools. If it is necessary to enter a hazardous atmosphere to accomplish your assignment, you are required to use SCBA. If you will be performing tasks around the exterior and are not wearing the SCBA face mask, you are required to wear eye protection.

This is not a timed event; however, you should complete this event within a reasonable fireground time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and half of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: 1st Attempt 2nd Attempt Ventilation - Horizontal 1. Confirms order to perform horizontal ventilation. 2. Properly dons personal protective clothing and SCBA. 3. Carries ventilation tools, ladders, and equipment properly. 4. Uses ventilation tools and equipment properly. 5. Performs horizontal ventilation in an effective manner. 6. If glass was broken, it was done safely and properly. 7. Operates as a member of a team. 8. Notifies Command upon completing horizontal ventilation.

Ventilation - Vertical 1. Confirms order to perform vertical ventilation. 2. Properly dons personal protective clothing and SCBA. 3. Selects, carries, deploys, and secures ground ladders for ventilation activities. 4. Carries ventilation tools and equipment properly ascending and descending ladder. 5. Sounds roof prior to leaving ladder. 6. Deploys roof ladders properly. 7. Hoists tools and equipment properly. 8. Uses ventilation tools and equipment properly. 9. Performs vertical ventilation in an effective manner. 10. Operates as a member of a team. 11. Notifies Command upon completing vertical ventilation.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 54 -

Fire Fighter I Skills Assessment FGE Sheet #5

COMBAT A GROUND COVER FIRE

JPR: NFPA 1001 – 2019 Edition, Section 4.3.19 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 14-11, 14-12 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 21-1

Candidate Equipment Required: Full personal protective clothing or complete wildland fire fighting ensemble Evaluator Equipment Required: Terrain model, hand tools, pumper (or wildland apparatus), attack (or forestry) hose and nozzle

Read to Candidate: For this skill event, you will operate as a member of a team to combat a simulated ground cover fire. You will be required to construct a fire line using hand tools. Prior to constructing the fire line, you must verbally identify potential threats to your safety and potential threats to exposures. Once the fire line is established, you must ensure fire line integrity is maintained. I will then ask you to extinguish fire using hand tools. Once fire is controlled, I will then direct you to use water to suppress any remaining fire. If I order you to retreat, you must react properly. It is important you verbalize your thoughts related to hazard assessment and safety considerations.

To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in ITALICS).

P-Pass / F-Fail: 1st Attempt 2nd Attempt Construct Fire Line 1. Confirms order to construct fire line. 2. Properly dons personal protective clothing and SCBA. 3. Determines potential threats to safety. 4. Determines potential threats to exposures. 5. Protects exposures. 6. Constructs a fire line. 7. Maintains integrity of established fire lines. 8. Properly uses hand tools. 9. Suppresses ground cover fire using water. 10. Uses progressive hose lay to advance hose line. 11. Ensures ground cover fire was suppressed. 12. If retreat was ordered, it was accomplished quickly and safely. 13. Operates as a member of a team. 14. Notifies Command when fire line is completed.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 55 -

FIRE FIGHTER II

MANIPULATIVE SKILL SHEETS

- 56 -

Fighter II Skills Assessment Skill Sheet #1

UTILIZE AN INCIDENT MANAGEMENT SYSTEM

JPR: NFPA 1001 – 2019 Edition, Section 5.1.2 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 19-1 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 22-1 THRU 22-3

Candidate Equipment Required: Full personal protective clothing Evaluator Equipment Required: Fire department radio and simulated incident

Read to Candidate: For this skill event, you will be required to function as the company officer of the first arriving company. Once I read to you the scenario you will implement an Incident Management System (IMS). You will utilize the IMS until you transfer Command. Once you transfer Command, you will operate in the role assigned by Command.

This is not a timed event; however, you should complete the assignment as expeditiously as possible. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in italics). P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Determines the need for command. ______2. Sizes up the incident. ______3. Communicates size-up results to dispatch and/or incoming units. ______4. Assumes command of the incident. ______5. Identifies incident priorities, strategies, and objectives. ______6. Requests additional resources (if required). ______7. Organizes and coordinates the IMS. ______8. Provides briefing to senior officer who is assuming Command. ______9. Transfers command. ______10. Functions in assigned IMS role after transfer of command.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 57 -

Fire Fighter II Skills Assessment Skill Sheet #2

COMPLETE A BASIC INCIDENT REPORT

JPR: NFPA 1001 – 2019 Edition, Section 5.2.1 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 19-2 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: None included; refer to pgs 846 and 847

Candidate Equipment Required: Station uniform clothing Evaluator Equipment Required: NFIRS report and scenario

Read to Candidate: For this skill event, you will be required to complete a basic incident report given a written scenario. Complete the report using only the information provided in the written scenario and by the evaluator. DO NOT fabricate information. The report should utilize appropriate codes. If available, report should be completed utilizing a computer.

This is not a timed event. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD). P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Completes basic Incident Report form using appropriate codes. ______2. Proofreads report to verify information is accurate and complete (including signature). ______3. Properly uses forms or computer to complete incident report.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 58 -

Fire Fighter II Skills Assessment Skill Sheet #3

COMMUNICATE THE NEED FOR ASSISTANCE

JPR: NFPA 1001 – 2019 Edition, Section 5.2.2 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 10-7 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 18-1

Candidate Equipment Required: Full personal protective clothing, SCBA and portable radio Evaluator Equipment Required: Fire department incident scenario

Read to Candidate: For this skill event, you will be required to communicate the need for team or individual assistance (Mayday). You will be required to use a fire department radio to communicate a Mayday (need for assistance). I will provide the nature of the assistance need and information regarding your location.

This is not a timed event. To pass this station, you must successfully complete 100% of the critical steps (steps BOLD) and a majority of the non-critical steps (steps in italics).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Recognizes the need for team/individual assistance. ______2. Operates communications equipment to request assistance. ______3. Depresses the transmit button and held it down until transmission was complete. ______4. Holds microphone 1 to 2 inches from mouth whiling transmitting message. ______5. Announces “Mayday” traffic. ______6. Transmits “Mayday” information. ______7. After message transmission is complete, activates PASS and follows IC’s orders or department guidelines.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 59 -

Fire Fighter II Skills Assessment Skill Sheet #4

EXTINGUISH AN IGNITABLE LIQUID FIRE

JPR: NFPA 1001 – 2019 Edition, Section 5.3.1 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 18-1, 18-2 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 23-3 thru 23-6

Candidate Equipment Required: Full personal protective clothing and SCBA Evaluator Equipment Required: Fire department pumper, simulated ignitable liquid fire, foam concentrate, foam proportioner, water supply, and attack line

Read to Candidate: For this skill event, you will be required to operate as a member of a team to extinguish an ignitable liquid fire given foam concentrates, a foam proportioning device, water supply, and an attack line. You must select the proper type of foam concentrate for the simulated ignitable fire, assemble foam stream components, and then apply the foam stream in an appropriate manner to create and maintain a foam blanket for extinguishing the fire. You must also prevent re-ignition of the liquid fire. Your team must then maintain a foam stream for protection and continue facing the hazard while retreating to a safe haven.

This is not a timed event. To pass this station, you must successfully complete 100% of the critical steps (steps BOLD) and a majority of the non-critical steps (steps in italics).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Confirms order to extinguish ignitable liquid fire. ______2. Properly dons personal protective clothing and SCBA. ______3. Selects proper type of foam concentrate for fuel. ______4. Prepares foam concentrate supply for use. ______5. Assembles foam stream components. ______6. Safely approaches the fire as a member of a team. ______7. Applies foam stream to surface using appropriate application technique(s). ______8. Extinguishes fire. ______9. Maintains foam blanket, preventing re-ignition. ______10. Team retreats while facing hazard until reaching a safe haven. ______11. Notifies Command upon exiting the hazardous area.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 60 -

Fire Fighter II Skills Assessment Skill Sheet #5

COORDINATE AN INTERIOR ATTACK

JPR: NFPA 1001 – 2019 Edition, Section 5.3.2 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 19-1 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 23-1

Candidate Equipment Required: Full personal protective clothing and SCBA Evaluator Equipment Required: Fire department resources (appropriate for conducting interior attack), water supply, attack line, simulated interior fire, and fire department radio

Read to Candidate: For this skill event, you must demonstrate the coordination of the initial resources assigned for an interior fire attack. You will assume command and function as the incident commander (IC). You will be required to evaluate fire growth and development, utilize correct attack techniques, communicate the incident action plan (IAP) to team members, and establish/maintain team integrity. You must also choose appropriate tools and equipment for entry. In addition, you will be responsible for coordinating search, rescue, and ventilation efforts with the efforts of the fire attack team. You must recognize developing or hazardous building conditions, report hazards to attack team members, and apprise resources of changing conditions. The evaluator will act as a higher-ranking officer to whom command will be transferred.

This is not a timed event. To pass this station, you must successfully complete 100% of the critical steps (steps BOLD) and a majority of the non-critical steps (steps in italics).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Confirms order to attack fire. ______2. Properly dons personal protective clothing and SCBA. ______3. Organizes and briefs resources. ______4. Evaluates and forecasts fire’s growth and development. ______5. Selects appropriate access location. ______6. Identifies tools required for forcible entry. ______7. Selects appropriate attack techniques for given fire. ______8. Communicates attack techniques to the attack team. ______9. Determines developing hazardous building or fire conditions. ______10. Maintains constant coordination. ______11. Continuously evaluates fire growth and development. ______12. Incorporates search and rescue as part of fire attack effort. ______13. Incorporates ventilation as part of fire attack effort. ______14. Resources apprised of changing conditions. ______15. Notifies Command upon exiting structure.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 61 -

Fire Fighter II Skills Assessment Skill Sheet #6

CONTROL A FLAMMABLE GAS CYLINDER FIRE

JPR: NFPA 1001 – 2019 Edition, Section 5.3.3 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 18-3 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 23-2

Candidate Equipment Required: Full personal protective clothing and SCBA Evaluator Equipment Required: Two fire department engines, simulated flammable gas cylinder, two hydrants for water supply, two attack lines (one from each engine), and two back-up lines (one from each engine)

Read to Candidate: At this station, you will operate as a member of a team with one team member designated as team the leader. Your team will be given a simulated flammable gas cylinder fire to control outside a structure. You must apply water using a technique appropriate for the given simulated flammable gas cylinder fire. Each team member must constantly evaluate the cylinder’s integrity, as well as changes in conditions. The team must approach/retreat while facing the cylinder and all team members must remain behind the protective fire streams. The designated team leader will be required to operate the simulated shut off valve. The fire must not be extinguished until the fuel has been shut off. Once the shut-off has been operated, the team will retreat to a safe distance under the protection of water application. Note that although a candidate will be designated as team leader, all team members will function under the supervision of assigned support personnel.

This is not a timed event, but you should complete the assignment in a reasonable fireground time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in italics).

Evaluator Note: Because of the danger of controlling even simulated flammable gas cylinder fires, this test scenario must be conducted under the direct supervision of designated support personnel. Support personnel are responsible for supervising the assigned team leader and ALL Fire Fighter II candidate team members.

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Confirms order to attack flammable gas cylinder fire. ______2. Properly dons personal protective clothing and SCBA. ______3. Identifies any possible place of shelter or safe haven. ______4. Advances safely and effectively. ______5. Applies water effectively. ______6. Cylinder integrity and changing cylinder conditions are monitored. ______7. Operates control valve to stop fuel flow. ______8. Implements effective procedures as conditions change. ______9. Flames are not intentionally extinguished by water application. ______10. Retreat is safe and effective. ______11. Notifies Command upon retreating to safety.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 62 -

Fire Fighter II Skills Assessment Skill Sheet #7

PROTECT EVIDENCE OF FIRE CAUSE AND ORIGIN

JPR: NFPA 1001 – 2019 Edition, Section 5.3.4 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 20-1 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: None included; refer to pgs 1038 thru 1054

Candidate Equipment Required: Helmet, safety glasses, safety boots Evaluator Equipment Required: Simulated burn scene, fire scenario, appropriate containers, barrier tape, flashlight

Read to Candidate: At this station, you will be required to protect evidence of fire cause and origin given a burn scenario. You will be responsible for verbalizing to the evaluator anything that you cannot physically complete. After observing the burn area, you must state the possible fire cause and area of origin. You must be able to explain how you came to your conclusion or determination. If you are unable to physically protect the evidence, you must verbalize how evidence would be protected until an investigator arrives.

This is not a timed event, but you should complete the assignment in a reasonable fireground time. To pass this station, you must successfully complete 100% of the steps below.

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Secures simulated fire scene to keep unauthorized persons away. ______2. Locates the potential area of origin. ______3. Recognizes possible causes. ______4. Takes appropriate safeguards to protect possible evidence. ______5. Does not unnecessarily move possible evidence. ______6. Notifies Command of findings and actions.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 63 -

Fire Fighter II Skills Assessment Skill Sheet #8

VEHICLE EXTRICATION

JPR: NFPA 1001 – 2019 Edition, Section 5.4.1 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 17-2 thru 17-9 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 24-1 thru 24-11

Candidate Equipment Required: Full personal protective clothing and eye protection Evaluator Equipment Required: Salvaged automobile, standard complement of powered rescue tools, hand tools, cribbing material, and rescue manikin

Read to Candidate: At this station, you will be required to operate as a member of a team to extricate a victim entrapped in a simulated motor vehicle accident. You will be required to conduct a scene size up, establish safety barriers, assess the need for extrication, determine the condition of vehicle, identify hazards to include the supplemental restraint system, stabilize the vehicle, and perform necessary extrication so the entrapped victim can be safely removed from the vehicle. You must verbalize your size up, your assessment of the need for extrication, your determination of vehicle condition, and your assessment of any hazards. When performing the extrication, the entrapped victim must be appropriately protected to prevent further injury. Actions that would cause further injury to the victim will result in failure of this skill event. I will identify the components of the vehicle required to be moved or removed such as the roof, doors, dash, etc. NOTE: The victim WILL NOT be removed from the motor vehicle.

This is not a timed event, but you should complete the assignment in a reasonable fireground time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in italics).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Confirms order to perform vehicle extrication. ______2. Properly dons personal protective clothing and SCBA. ______3. Sizes up scene, including condition of vehicle. ______4. Assesses potential hazards. ______5. Establishes safety barrier. ______6. Effectively uses cribbing and/or shoring materials to stabilize vehicle. ______7. Safely operates power and/or hand tools. ______8. Chooses and applies effective techniques for moving or removing: (as appropriate) • Vehicle roof • Doors • Windshield • Side and/or rear glass windows • Steering wheel/column • Dashboard ______9. Assesses supplemental restraint systems and deals with it appropriately. ______10. Appropriately protects victim throughout vehicle extrication operation. ______11. Operates as a member of a team. ______12. Notifies Command upon completing extrication.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 64 -

Fire Fighter II Skills Assessment Skill Sheet #9

ASSIST RESCUE OPERATION TEAMS

JPR: NFPA 1001 – 2019 Edition, Section 5.4.2 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 17-1 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 25-1, 25-2

Candidate Equipment Required: Full personal protective clothing Evaluator Equipment Required: Cache of rescue tools and equipment, barrier tape, cones, and signs

Read to Candidate: At this station, you will be required to assist a rescue operation team. I will serve as the rescue team’s leader. I will direct you to retrieve various types of rescue tools, establish hazard zone barriers to protect the public, and assist the rescue team with various tasks required to commensurate with NFPA 1001, Fire Fighter II level of training.

This is not a timed event, but you should complete the assignment in a reasonable fireground time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and at least one of the non- critical steps (steps in italics).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Confirms order to assist rescue operation team. ______2. Properly donned personal protective clothing and SCBA. ______3. Identifies and retrieves correct tools and equipment as directed by rescue team. ______4. Establishes safety barriers to protect public. ______5. Assists rescue team as an assigned member, when assigned by rescue team. ______6. Notifies Command upon completing assignment.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 65 -

Fire Fighter II Skills Assessment Skill Sheet #10

PERFORM A FIRE SAFETY SURVEY IN A PRIVATE DWELLING

JPR: NFPA 1001 – 2019 Edition, Section 5.5.1 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 22-1 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 27-5

Candidate Equipment Required: Station uniform clothing Evaluator Equipment Required: Survey forms, hand light, and fire safety information material

Read to Candidate: For this skill performance evaluation, you will perform a fire safety survey in a private dwelling given a residential survey form, fire and life safety information material, and any necessary equipment. You are required to conduct the fire safety survey and provide fire and life safety information.

This is not a timed event, but you should complete the assignment in a reasonable time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in italics).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Gathers information and material to conduct survey. ______2. Contacts resident. ______3. Explains purpose of survey to resident. ______4. Conducts survey. ______5. Recognizes hazards. ______6. Matches findings to preapproved safety list. ______7. Explains survey findings to resident. ______8. Concludes survey by providing fire and life safety information. ______9. Completes survey form and records results of survey according to policy.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 66 -

Fire Fighter II Skills Assessment Skill Sheet #11

PRESENT FIRE SAFETY INFORMATION TO STATION VISITORS OR SMALL GROUPS

JPR: NFPA 1001 – 2019 Edition, Section 5.5.2 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 22-2, 22-3 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 27-1 thru 27-4

Candidate Equipment Required: Station uniform clothing Evaluator Equipment Required: Lesson outline, media equipment, and instructional material

Read to Candidate: At this station, you will present a fire safety information program, given a lesson outline, media equipment, and instructional materials. You are required to present the assigned topic according to the lesson outline in a manner appropriate for the audience.

This is not a timed event, but you should complete the assignment in a reasonable time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in italics).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Determines audience and lesson topic to be taught. ______2. Determines location, date, and time for presentation. ______3. Properly prepares to deliver presentation. ______4. Introduces self and topic. ______5. Follows prepared lesson outline. ______6. Familiar with equipment and material used to present topic. ______7. Returns equipment, material, and lesson outline after presentation. ______8. Records information according to policy.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 67 -

Fire Fighter II Skills Assessment Skill Sheet #12

PREPARE A PRE-INCIDENT SURVEY

JPR: NFPA 1001 – 2019 Edition, Section 5.5.3 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 22-4 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 27-6

Candidate Equipment Required: Station uniform clothing Evaluator Equipment Required: Pre-incident survey forms, sketch pad, building to survey, and surveyor’s wheel

Read to Candidate: At this station, you must conduct a pre-incident survey given pre-incident survey forms, a sketch pad, building to survey, and surveyor’s wheel. After conducting the pre-incident survey, you must prepare the pre-incident survey forms provided. I will serve as the building owner/occupant.

This is not a timed event, but you should complete the assignment in a reasonable time. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD) and a majority of the non-critical steps (steps in italics).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Gains permission to conduct survey. ______2. Explains purpose of survey. ______3. Sketches outside of building. ______4. Records outside observations. ______5. Sketches inside of building. ______6. Records inside observations. ______7. Recognizes components of fire suppression and detection systems. ______8. Recognizes building construction features. ______9. Recognizes special features. ______10. Detects potential hazards. ______11. Identifies special considerations. ______12. Discusses results of survey with owner/manager. ______13. Completes all fields on given survey.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 68 -

Fire Fighter II Skills Assessment Skill Sheet #13

MAINTIAN POWER PLANTS, POWER TOOLS, AND LIGHTING EQIUPMENT

JPR: NFPA 1001 – 2019 Edition, Section 5.5.4 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 21-1, 21-2 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 25-3

Candidate Equipment Required: Station uniform clothing and safety glasses Evaluator Equipment Required: Power plant, lighting equipment, power cords, power tools (chainsaw, circular saw, reciprocating saw, and extrication power unit), maintenance hand tools, and appropriate manufacturer’s equipment instruction manuals

Read to Candidate: At this station, you will be required to perform “operator-level” maintenance and repair on power plants, power tools, and lighting equipment per the manufacturer’s guidelines. You must ensure the power plant, power tool, and lighting equipment is clean and functional. All operator-level corrective actions required must be completed. Any power plant, power tool, or lighting equipment requiring more than operator-level corrective action should be removed from service and marked/tagged. Inoperable equipment should be reported to the appropriate person.

This is not a timed event, but you should complete the assignment as expeditiously as possible. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD).

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Selects appropriate hand tools required to perform maintenance and equipment check. ______2. Follows manufacturer’s guidelines. ______3. Operator-level corrective actions are taken to repair equipment (if required). ______4. Operates power plants, power tools, and lighting equipment following maintenance and check. ______5. Completes recording and reporting requirements.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 69 -

Fire Fighter II Skills Assessment Skill Sheet #14

PERFORM ANNUAL SERVICE TEST ON FIRE HOSE

JPR: NFPA 1001 – 2019 Edition, Section 5.5.5 Reference: IFSTA, Essentials of Fire Fighting©, 7th edition, 2018 Skill Sheets: 21-3 Jones and Bartlett, Fundamentals of Fire Fighter Skills and Hazardous Materials Response©, 4th Edition, 2019 Skill Drills: 23-7

Candidate Equipment Required: Full personal protective clothing (bunker pants, helmet and gloves are appropriate during hot weather) Evaluator Equipment Required: Fire department pumper or hose testing machine, fire department hose, spanner wrenches, marking device, watch, water source, and appropriate valves and appliances for conducting hose test

Read to Candidate: At this station, you will be required to perform an annual service test on fire hose, given a fire department pumper or hose testing machine, fire hose to be tested, fire hose testing equipment, and hose record forms.

This is not a timed event, but you should complete the assignment as expeditiously as possible. To pass this station, you must successfully complete 100% of the critical steps (steps in BOLD).

Evaluator Note: Referring to critical step 6 below, service test used during this skill event are based on the recommendations found in NFPA 1962. Fire hose that is not clearly marked with the date of manufacture and/or the required service test pressure WILL BE TESTED based on service test pressures identified in NFPA 1962 for fire hose manufactured prior to July 1987.

P-Pass / F-Fail: 1st Attempt 2nd Attempt

______1. Visually inspects hose for possible damage prior to conducting test. ______2. Checks couplings for damage, function, and gaskets. ______3. Marks hose at couplings to identify potential coupling slippage. ______4. Operates hose testing equipment to charge fire hose. ______5. Bleeds off air and tightens leaking couplings once fire hose is filled with water. ______6. Operates hose testing equipment to conduct service test. ______7. Walks the entire length of charged hose line from a safe distance checking for obvious leaks. ______8. Walks the entire length of hose after pressure is eliminated, checking for signs of leaks and coupling slippage. ______9. Removes hose from service that fails the service test. ______10. Records results on hose record form and filed records according to policy.

Candidate’s Name: Station: P F P F 1st Attempt 2nd Attempt Evaluator’s Signature:

- 70 -

APPENDIX A

TRAINING RECORDS

- 71 -

FIRE FIGHTER TRAINING RECORD: FFI 2019 Standard

TRAINING IN-HOUSE CORRESPONDING SECTION RECORD COM. EXAM MANIPULATIVE SKILLS - DEMONSTRATE SKILL SHEET DATE INST HRS DATE INST P/F Documentation of prerequisite training completion N/A Prerequisite Completed structural-based live-fire training N/A Care/Inspection/Maintenance of protective clothing 1 General Don/Doff structural fire fighter protective clothing 1 Receive a report from a telephone 3 Fire Department Demonstrate receiving business call from the public 3 Communications Demonstrate the use of portable radio equipment 4 Communicate the need for assistance (MAYDAY) 1 Identify/Describe components of SCBA 26 Demonstrate donning/doffing an SCBA 1 Use SCBA in restricted passage 1 Conservation of air (skip breathing) 1 Emergency procedures: face piece failure 1 Emergency procedures: interruption of air 1 SCBA Emergency procedures: "free-flow" of air 1 Emergency procedures: exhalation valve being seared 1 shut

Doff and perform a check of an in-service SCBA 1 without cylinder change

Doff and perform a check of an in-service SCBA with 1 cylinder change Inspect/Clean/Sanitize SCBA 24 Demonstrate safety while responding on apparatus 5 ER Response Establish and operate in work areas at an emergency 6 scene

72

FIRE FIGHTER TRAINING RECORD: FFI 2019 Standard TRAINING IN-HOUSE CORRESPONDING SECTION RECORD COM. EXAM MANIPULATIVE SKILLS - DEMONSTRATE SKILL SHEET DATE INST HRS DATE INST P/F

Proper care/maintenance of forcible entry hand tools 27 and equipment Force entry on swinging door 7a Force entry on sliding door 7a Force entry on overhead door 7a Forcible Entry Force entry on sliding window 7b Force entry on double-hung window 7b Force entry on casement window 7b Force entry on masonry wall 7c Force entry on metal wall 7c Force entry on wood wall 7c Demonstrate exiting using a hose/tag line 8 Safety Demonstrate exiting using a wall 8 Demonstrate carry/position/raise/lower ladders/24' & 9 35' Demonstrate climbing, working on and descending 9 ladder Ladders Demonstrate bringing a victim down a ladder 9 Deploy roof ladder on pitched roof 9 Inspect, maintain, and clean aerial or ground ladder 22 Hydrant-to-pumper connection: forward hose lay 17 Hydrant-to-pumper connection: reverse hose lay 17 Demonstrate hand lay of 200' 2 ½" hose, pumper to 17 Water Supply water Assemble equipment for drafting operation: static 18 source Assemble equipment for drafting operation: portable 18 tank 73

FIRE FIGHTER TRAINING RECORD: FFI 2019 Standard TRAINING IN-HOUSE CORRESPONDING SECTION RECORD COM. EXAM MANIPULATIVE SKILLS - DEMONSTRATE SKILL SHEET DATE INST HRS DATE INST P/F Demonstrate set-up of a master stream device FGE 2 Demonstrate proper method for extending a charged FGE 3 line Demonstrate proper method for replacing burst section FGE 3 Couple/uncouple hose: foot-tilt method FGE 3 Couple/uncouple hose: two-fire fighter method FGE 3 Advance attack line into structure FGE 3 Advance attack line up ladder to second floor window 9/FGE 3 or roof Hose, Nozzles, Advance attack line up/down, inside/outside stairway FGE 3 Appliances Single hose section drain and carry 28 Accordion shoulder carry 28 Load supply hose using flat or accordion hose loads 28 Load attack hose lines using flat, triple layer, 28 minuteman Demonstrate a straight roll 29 Demonstrate a donut roll 29 Demonstrate cleaning, inspecting, maintaining fire hose 28/29 Demonstrate cleaning, inspecting, maintaining nozzles 28/29 Search for victim in structure and remove 12 Move victim 40' using extremity carry 12 Move an unconscious victim 40' using a blanket drag 12 Search and Rescue Remove unconscious fire fighter with functioning 10 SCBA using appropriate carry/drag

Remove unconscious fire fighter with non-functioning 11 SCBA using appropriate carry/drag

74

FIRE FIGHTER TRAINING RECORD: FFI 2019 Standard TRAINING IN-HOUSE CORRESPONDING SECTION RECORD COM. EXAM MANIPULATIVE SKILLS - DEMONSTRATE SKILL SHEET DATE INST HRS DATE INST P/F Clean and inspect ventilation equipment 23 Determine integrity of a roof by sounding FGE 4 Break glass while working from ground FGE 4 Break glass while working from ladder FGE 4 Ventilation Open ventilation on a pitched/flat roof FGE 4 Open ventilation on a floor FGE 4 Set-up smoke ejector using "negative" pressure FGE 4 Set-up blower fan for "positive" pressure FGE 4

Overhaul Expose and extinguish hidden fires in walls, ceilings, 13 and floors Air 14 Monitoring Operate Air Monitoring System Fold/roll salvage cover for one-fire fighter spread 15 Fold/roll salvage cover for two-fire fighter spread 15 Demonstrate one-fire fighter deployment 15 Demonstrate two-fire fighter deployment (balloon 15 throw) Conserve Construct water chute 15 Property Construct catchall 15 Cover/close building openings 15 Separate charred from uncharred material 15 Stop flow from discharging sprinkler head 16 Operate main control valve 16 Inspect/Clean/Maintain salvage cover 26 Use a portable fire extinguisher on Class A, B, and C Extinguishers 19 fires.

75

FIRE FIGHTER TRAINING RECORD: FFI 2019 Standard TRAINING IN-HOUSE CORRESPONDING SECTION RECORD COM. EXAM MANIPULATIVE SKILLS - DEMONSTRATE SKILL SHEET DATE INST HRS DATE INST P/F Demonstrate use of lighting equipment 20 Fire Ground Demonstrate shutting off propane or natural gas valve 21 Secure power to structure: shut off main power 21 breaker Demonstrate how to clean, inspect, and store rope 25 Demonstrate how to tie a clove hitch 2 Demonstrate how to tie a Becket Bend 2 Demonstrate how to tie a Bowline 2 Demonstrate how to tie a figure eight 2 Demonstrate how to tie a figure eight on a bight 2 Demonstrate how to tie a figure eight follow through 2 Ropes and Demonstrate how to tie a rescue knot 2 Knots Demonstrate how to tie a girth hitch 2 Demonstrate how to tie a running bowline 2 Demonstrate how to tie and hoist a pike pole 2 Demonstrate how to tie and hoist an axe 2 Demonstrate how to hoist a dry line 2 Demonstrate how to hoist a charged line 2 Demonstrate how to tie and raise a vent saw 2 Demonstrate how to tie and raise a ladder 2 Demonstrate an offensive attack on a vehicle fire FGE 1 Demonstrate an offensive attack on an exterior Class A FGE 2 fire Demonstrate an offensive attack on an interior Fire Ground FGE 3 Evolutions structure fire Demonstrate an offensive attack on a ground cover fire FGE 5 Demonstrate horizontal ventilation FGE 4 Demonstrate vertical ventilation FGE 4 76

FIRE FIGHTER TRAINING RECORD: FFII 2019 Standard TRAINING IN-HOUSE CORRESPONDING SECTION RECORD COM. EXAM MANIPULATIVE SKILLS - DEMONSTRATE SKILL SHEET DATE INST HRS DATE INST P/F Demonstrate procedures for assuming and General transferring command at an emergency scene using 1 the ICS system Complete an incident report 2 Communications Communicate the need for assistance 3

Demonstrate procedures to extinguish combustible 4 liquids fire Fire Ground Coordinate an interior attack during a structure fire 5 Operations Control fire involving gas cylinder - Master stream 6 Control fire involving gas cylinder - Fire attack 6 Protect evidence of fire cause and origin 7

Demonstrate evolution of displacing vehicle glass to 8 include windshield Demonstrate the evolution of displacing a vehicle roof 8 Demonstrate the evolution of displacing a vehicle door 8 Rescue Operations Demonstrate the evolution of displacing steering 8 wheel/steering column" Demonstrate evolution of displacing a vehicle 8 dashboard Assist rescue operations teams 9 Demonstrate inspection procedures for a private 10 dwelling Present a fire safety information program 11 Prevention, Preparedness, Prepare a pre-incident survey 12 Maintenance Demonstrate the service and maintenance of power 13 plants and lighting equipment Demonstrate annual service test for fire hose 14

77

APPENDIX B – EXAMINATION

REQUEST FORM

78

EXAMINATION REQUEST FORM

Please complete all information on BOTH sides of this form and return to the NDFA at least 30 days prior to the requested examination date. A separate request MUST be made for each level of certification exam desired and for each exam date. Send completed forms to [email protected].

Examination Request for Written / Skills – Check the appropriate level Basic Level Discipline Written Manipulative Written Manipulative Curriculum Edition Fire Fighter FFI   FF II   J&B

Number Taking Written Examination: Number Taking Manipulative Exam:

Requested Test Date(s): Requested Test Start Time(s): ______

Testing Tablets Needed for Written Examination: ______

Examination Location:

Contact Name: Department Name and Address:

Contact Phone Number:

By the signature below we acknowledge that training records exist to support that everyone who will attend the exam has received a learning experience in each subject area required for testing and has met all other requirements for the level being examined for as specified in the Certification Policy and Procedures Manual. Department requesting the above exam, will have appropriate space and safe accommodations and equipment for all written and manipulative skills

Fire Chief/Head of Department (Signature) Training Officer (Signature)

Fire Chief/Head of Department (Typed/Printed) Training Officer (Typed/Printed)

79

Type or print names of candidates taking examination

Candidates Printed Name Department Last Four of Email SSN 1 XXX-XX- 2 XXX-XX- 3 XXX-XX- 4 XXX-XX- 5 XXX-XX- 6 XXX-XX- 7 XXX-XX- 8 XXX-XX- 9 XXX-XX- 10 XXX-XX- 11 XXX-XX- 12 XXX-XX- 13 XXX-XX- 14 XXX-XX- 15 XXX-XX- 16 XXX-XX- 17 XXX-XX- 18 XXX-XX- 19 XXX-XX- 20 XXX-XX- 21 XXX-XX- 22 XXX-XX- 23 XXX-XX- 24 XXX-XX- 25 XXX-XX-

Send Request form to:

North Dakota Firefighter’s Association 1502 Grumman Lane, Suite 2, Bismarck, ND 58504 Fax: (701) 222-2899 Email: [email protected]

80

APPENDIX C – CANDIDATE

ACKNOWLEDGEMENT FORM

81

Candidate Testing Acknowledgement Form

I (print/type your name) acknowledge that I have been scheduled for my certification test. I have read and understood the applicable standard and am fully aware of the prerequisites for the certification for which I am testing. I also understand that I must present a copy of my training record and any proof of prerequisite completion prior to being tested unless it has been documented by NDFA prior to. I further acknowledge that it is my sole responsibility to ensure that this documentation has been met.

Please initial each statement below and sign where indicated:

I acknowledge the required prerequisites for the level for which I am testing on and will ensure I present any to the evaluator prior to testing.

I understand that failure to follow the above requirement will result in my exam being cancelled.

SIGNATURE: I indicate by my signature below that I have read the terms and conditions of this protocol and acknowledge that I understand it. My signature below indicates that I have read and freely signed this agreement, which takes effect as a sealed instrument.

Candidate Signature Date

82