Electrical Test Instruments New Products

Total Page:16

File Type:pdf, Size:1020Kb

Electrical Test Instruments New Products Electrical test instruments New products DCM305E DET2/3 Advanced MFT1800 series AVO800 series Earth Leakage Earth (Ground) multifunction multimeters Clampmeter Tester installation testers ■ High end multimeters ■ Designed to check ■ Robust intrument ■ Offering increased designed with the earth leakage to measure earth functionality and electrical contractor in currents. See page 21 Electrode Resistance better value. See mind. See page 18 and Soil Resistivity. page 14 See page 25 Power on for over 120 years Since 1889 Megger, and its predecessor companies, has been In 1923 Megger was brought the idea of the multimeter helping electrical engineers keep the power on by developing by Donald Macadie. Measuring amps volts and ohms in a and manufacturing portable test and measurement tools. single instrument was revolutionary and the AVOmeter Insulation testers were first to be developed; this lead to the model 1 was born. 85 years later the last model 8 mark 7 registration of the Megger brand as long ago as 1903. -- came off the production line and in this catalogue Megger is launching the AVO830 range of multimeters. The original insulation testers came in two boxes, separating the voltage generation from the measurement circuit, to George Tagg, working at Megger in the 1960’s published avoid electromagnetic interference problems. It was some a seminal paper on earth testing His work was concerned time later that they were combined in a bakelite box with particularly with earth electrode systems that covered the iconic handle for driving the dynamo. a large area. Today with the help of digital electronics, and revolutionary electronic components, Megger is Five years later the low resistance ohmmeter (LRO) was continuing its mission of making your life easier by invented, these became known the world over as Ducter developing more powerful and safer testers that are light testing. Housed in wooden cases, these testers had a long to carry, comfortable to hold and easier for you to use, and admirable history, in fact Megger has been given an helping you to Power on. early LRO that was still in calibration in 2006. Trying to decide which Megger They’ll talk through your needs tester is best for you? and the way you work and help you make the right decision for Call your local Megger your business. Reach us at distributor. [email protected] Electrical test equipment Insulation and continuity testers For electricians ................................................ 4 to 6 For maintenance engineers ...................................7 For power engineers ...................................... 7 to 9 For communications engineers ...........................28 Low resistance testers ................................ 10 to 13 Multifunction installation testers .............. 14 to 15 Residual current device tester Single function......................................................16 Multifunction Installation testers...............14 to 16 Power quality Power quality analyser..........................................36 Multifunction Installation testers................14 to 15 Earth testing Earth leakage current clamp ...............................21 Earth loop impedance testing ................... 22 to 23 Multifunction Installation testers...............14 to 15 Earth electrode resistance testing .......................24 Advanced earth testing and kits .........................25 Other tester Multimeters.................................................18 to 21 Clamp meters..............................................20 to 21 Fault locators or TDRs for electrical and communications engineers.........................26 to 27 Oil test set .............................................................32 Relay testing .........................................................33 Battery impedance tester .......................... 34 to 35 Power quality tester .............................................36 Handheld online PD substation surveying ..........37 Cable fault location systems................................38 Underground cable fault pin-pointing..............39 Cable route tracing and identification............40 Cable height meters........................................41 Transformer turns ratio testers.....................45 Solar PV testing............................................42 Phase Sequence Indicator..........................43 Voltage detection...........................43 to 44 www.megger.com 3 Insulation and continuity testers MIT200 series MIT200 Series is one of the smallest insulation testers available Both products have a combination of digital readout and Continuity testing analogue display, using Megger’s patented DART display ■ Automatic continuity testing is performed at 200 technology. The display includes a clear, accurate digital read- mA to ensure compliance with international re- out, and an analogue pointer response for evaluating circuit quirements. No need to press the test button charge and discharge characteristics. ■ All instruments will measure up to 100 Ω on The tough ABS instrument housing is designed to withstand the continuity, of which 0-10 Ω is performed at greater rigours of hard use, whilst small enough to drop into your pocket than 200 mA when not in use. A low battery warning indicator gives advanced warning of exhausted batteries. ■ Lead null is possible up to 9.99 Ω ensuring the ability to null fused test leads as well as standard Insulation testing leads ■ There is a choice of two or three test voltage ■ Voltage protection should you touch a live circuit ranges providing an ideal solution to most low voltage insulation testing applications ■ Continuity buzzer provides a means of rapid cable testing and circuit identification, with voltage ■ Insulation measurement up to 1000 MΩ on all protection should you accidentally touch a live ranges circuit ■ Auto discharge ensures all circuits are safely ■ The buzzer operates at a 5 Ω threshold discharged after testing ■ 1000 V insulation test ranges have a high voltage warning prior to test voltage being applied Accessories Special features Exceptional value for money Pocket sized tester Live circuit protected 1002-491 Red and black probes and clips MIT200 MIT210 MIT220 MIT230 Test volage 1000 V n n 500 V n n n n n 1002-015 250 V 2-wire 500 mA fused test lead set Insulation resitance to 1000 MΩ n n n n Coninuity measurement at 200 n n n n mA Fast buzzer range n n n n Voltage detection n n n n Intelligent safety system n n n n Display backlight n n n n CAT III 600 V n n n n 1002-001 Warranty upgradeable to 3 n n n n 2 wire test lead set years FREE 4 Electrical test instruments www.megger.com MIT300 series The Megger insulation testers are like no other tester you have used The Megger insulation testers will take the bashing ■ Live voltage warning alerts the user to a circuit that testers receive when they are on site voltage over 25 V when insulation testing They are rubber armoured and have an integral solid lid to protect ■ Safety lockouts – the display. The heavy-duty hinge allows the lid to be locked away – Prevents continuity testing on live circuits beneath when in use, making it easy to use and impossible to lose. – Prevents insulation testing when circuit And you don’t need to pull out the test leads to shut the lid. voltage is greater than 50 V The Megger MIT insulation testers are easy to use and Hands free operation quick to learn MIT300 series insulation testers are well balanced to hang There are no buried functions, so it is easy to use these insulation comfortably around your neck enabling hands free operation when testers. The colour coding helps test selection, speeding up testing you need it. The continuity test and buzzer start automatically when time and helping you identify faults fast. The quick start guide in the you connect to a circuit, saving you lid keeps all the basic information at hand if you need it. time. Insulation tests can be started using a switched probe or the test Your safety is Megger’s number one concern. These safety button on the front of the tester. features look after you and the tester Safety interlock to prevent unsafe connection of the test leads Safe contact detector keeping you and your tester safe during continuity testing if it’s accidentally connected to a live circuit MIT310A MIT300 MIT310 MIT320 MIT330 Analogue Accessories Insulation testing 250 V n n n n n 500 V n n n n n 1000 V n n n n Test range 1000 MΩ 1000 MΩ 1000 MΩ 1000 MΩ 1000 MΩ Insulation limit alarm 0.01 MΩ to 1000 MΩ n n Continuity testing Continuity to 100 Ω n n n n n Continuity buzzer n n n n n 1002-491 1 Red and black probes and clips Lead null to 9 Ω n n n < /2 Ω n Adjustable buzzer 1 to 100 Ω n n Audible buzzer disable n n Voltage measurement Volts AC/DC 600 V 600 V 600 V 600 V Resistance 10 Ω to 1 MΩ range n n measurement 1002-001 10 Ω to 2 KΩ range n 2 wire test lead set Features Voltage warning n Default voltmeter n n n n Backlit display n n Backlit selector ranges n n Locking test button n n n n n Auto power-down n n n n 1002-015 2-wire 500 mA fused test lead set Switched test probe n n Data storage n Download via USB port n IP54 weatherproof n n n n n Accepts rechargeable batteries n n n n n Included accessories 2 wire lead set n n n n n 1001-884 Remote switched probe with Free calibration certificate n n n n special plug Warranty upgradeable to 3 years FREE n n n n n www.megger.com 5 Insulation and continuity tester for electrical and industrial maintenance MIT400/2 series Features include: ■ Designed
Recommended publications
  • Subject: Electrical Technology First Class Lecture
    Electrical Technology Lecturer: Shahad Falih Republic of Iraq Ministry of Higher Education and Scientific Al-Mustaqbal University College Chemical Engineering and Petroleum Industries Department Subject: Electrical Technology First Class Lecture Two 1 Electrical Technology Lecturer: Shahad Falih Electric Circuits Standard symbols for electrical components Symbols are used for components in electrical circuit diagrams and some of the more common ones are shown in Figure below: 2 Electrical Technology Lecturer: Shahad Falih Basic electrical measuring instruments An ammeter is an instrument used to measure current and must be connected in series with the circuit. Figure 2.2 shows an ammeter connected in series with the lamp to measure the current flowing through it. Since all the current in the circuit passes through the ammeter it must have a very low resistance. 3 Electrical Technology Lecturer: Shahad Falih A voltmeter is an instrument used to measure p.d. and must be connected in parallel with the part of the circuit whose p.d. is required. In Figure 2.2, a voltmeter is connected in parallel with the lamp to measure the p.d. across it. To avoid a significant current flowing through it a voltmeter must have a very high resistance. An ohmmeter A is an instrument for measuring resistance. multimeter, or universal instrument, may be used to measure voltage, current and resistance. An ‘Avometer’ is a typical example. Ohm’s law Ohm’s law states that the current I flowing in a circuit is directly proportional to the applied voltage V and inversely proportional to the resistance R, provided the temperature remains constant.
    [Show full text]
  • Megger Canada
    Electrical Test Equipment Catalog WOULD YOU LIKE TO KNOW MORE? Sign up to ca.megger.com to gain exclusive access to: n Webinars Learn valuable testing tips and tricks from Megger application engineers and product managers. In this FREE, educational monthly webinar series, our experienced staff will show you how to make your testing more efficient by sharing their lessons learned in the field. You will find answers to frequently asked questions, learn how to avoid the most common mistakes and accelerate your testing. n Technical library The Megger technical library provides access to a range of additional content and resources such as technical guides, application notes and more. Use the filters to browse specific content (e.g. application notes) or refine your search to a particular electrical application area. n Where to buy Find out distributors you can buy our test instruments from. Megger Limited 550 Alden Road, Unit 106 Markham, ON L3R 6A8 Canada T: 416.298.6770 T: 1.800.297.9688 F: 416-298-0848 E: [email protected] ca.megger.com 2 Electrical Test Equipment ca.megger.com Table of Contents 5/10/15-kV INSULATION TEST EQUIPMENT ..................4 TIME DOMAIN REFLECTOMETERS .................................29 MIT515, MIT525, MIT1025 ...........................................4 CFL535G ......................................................................29 MIT1525 .......................................................................5 TDR2010 .....................................................................29 MIT30 ...........................................................................5
    [Show full text]
  • I INVESTIGATION of METHODS for DETECTING NEEDLE INSERTION INTO BLOOD VESSELS by Ehsan Qaium BS in Mechanical Engineering, Virgi
    INVESTIGATION OF METHODS FOR DETECTING NEEDLE INSERTION INTO BLOOD VESSELS by Ehsan Qaium BS in Mechanical Engineering, Virginia Tech, 2012 Submitted to the Graduate Faculty of the Swanson School of Engineering in partial fulfillment of the requirements for the degree of Master of Science in Mechanical Engineering University of Pittsburgh 2018 i UNIVERSITY OF PITTSBURGH SWANSON SCHOOL OF ENGINEERING This thesis was presented by Ehsan Bin Qaium It was defended on April 19,2018 and approved by William Clark, PhD, Professor Jeffrey Vipperman, PhD, Professor Cameron Dezfulian, MD, Associate Professor Thesis Advisor: William Clark, PhD, Professor ii Copyright © by Ehsan Qaium 2018 iii INVESTIGATION OF METHODS FOR DETECTING NEEDLE INSERTION INTO BLOOD VESSELS Ehsan Qaium, M.S. University of Pittsburgh, 2018 Peripheral intravenous IV (pIV) placement is the mainstay for providing therapies in modern medicine. Although common, approximately 107 million difficult pIV placements each year require multiple attempts to establish IV access. Delays in establishing IV access lead to increased patient pain, delayed administration of life saving medicine, and increased cost to the institution. Current solutions involve using visual vein finders, ultrasounds and a central line if peripheral IV insertion attempts fail. The objective of this study was to investigate methods by which entry into a blood vessel could be detected, and to design and test a novel medical device that increases the likelihood of successful pIV placement on the first attempt. Two types of measurement methods (static and transient) were investigated in this study. Static measurement involved measurements performed with a multimeter and a Wheatstone bridge. The multimeter measurement was unsuccessful due to the effect of polarization.
    [Show full text]
  • Senior Design 1
    Senior Design 1 Project Documentation The Smart Digital Voltmeter Sponsored by Commercial Lighting Enterprises Incorporated Department of Electrical Engineering and Computer Science University of Central Florida Dr. Lei Wei December 6, 2016 Group 19 William Brumby Electrical Engineering [email protected] Gaston Mulisanga Computer Engineering [email protected] Travis Ram Computer Engineering [email protected] Vladimir Tsarkov Electrical Engineering [email protected] Table of Contents Page 1. Executive Summary………………………………………………………………...1 2. Product Description………………………………………………………………....3 2.1 Motivation…………………………………………………………………...3 2.2 Goals and Objectives……………………………………………………...3 2.3 Requirements Specifications……………………………………………..4 2.4 Quality of House Analysis………………………………………………...6 Table 2.1: House of Quality Trade-Off Table…………………….…..6 3. Research……………………………………………………………………………..8 3.1 Technological Foundation………………………………………………...8 3.2 Existing Digital Voltmeter Projects and Products………………………8 Figure 3.1: T.K. Hareendran’s Project……...…………….…………10 Figure 3.2: Mayoogh Girish’s Project……………….....…………....10 3.2.1 Different Types of Voltmeters………………………………….11 3.3 Voltmeter Measurement Technologies………………………………....17 Figure 3.3: Selector switch (independent ranges).........................19 Figure 3.4: Selector switch (dependent ranges)............................19 3.4 Safety Hazards and Protective Measures……………………………...20 Figure 3.5: Good vs Bad Fuses………………....…………………..22 3.5 Strategic Components and Part Selections…………………………....26
    [Show full text]
  • Electrical Test Equipment Catalog
    Electrical Test Equipment Catalog 2016 Since 1889 Megger, and its predecessor companies, has been helping electrical engineers keep the power on by developing and manufacturing portable test and measurement tools. Insulation testers were first to be developped; this lead to the registration of the Megger brand in 1903. Five years later the low resistance ohmmetrer (LRO) was invented, these later becaome known as Ducter testing. Housed in wooden cases, these testers had a long and admirable history. In 2006, Megger was given an early LRO that was still in calibration! In 1923, Donald Macadie introduced the idea for the multimeter to Megger. Measuring amps, volts and ohms in a single instrument was revolutionary and the AVOmeter model 1 was born. 85 years later, Megger is launching the AVO830 range of multimeters. Today with the help of digital electronics and revolutionary electronic components, Megger is continuing its mission of making your life easier by developing more powerful and safer testers that are light to carry, conformatable to hold and easier for you to use, helping you to power on. 2 Electrical Test Equipment TABLE OF CONTENTS 5/10/15-KV INSULATION TEST EQUIPMENT ......... 4 TIME DOMAIN REFLECTOMETERS ........................ 29 MIT515, MIT525, MIT1025............................... 4 CFL535G Time Domain Reflectometer .............. 29 Transit case ...................................................... 4 TDR2010 Time Domain Reflectometer .............. 29 MIT1525 .........................................................
    [Show full text]
  • UNESCO / Higher Education - Erbil
    UNESCO / Higher Education - Erbil Tariff Code Description Qty Unit 06-06-00001 PC type computer + accessories 15 set 06-06-00002 Office (personal) laser printer with spare and accessories 5 set 06-06-00003 Color laser printer with spare and accessories 2 set 06-06-00004 Scanner size A4 color- high resolution with software 2 set 06-06-00005 Electrical pH meter; buffers, with spares and accessories 1 set 06-06-00006 Hot plate magnetic stirrer; temp., range 65- 510 deg. C, stirring 2 set range (50- 1800) rpm,with spares and accessories 06-06-00007 Dry oven; 150 L capacity, temp. range: 4- 250 deg. C temp. 2 set regulator and control system, with spares and accessories 06-06-00008 Micro-centrifuge; High speed 24 place rotor that accepts 1.5 ml 2 set tubes, 30 minute timer. 06-06-00009 Shaker water bath; (30Wx16Dx12H) inch, temp. range above 2 set ambient. to + 70 deg. C, with spares and accessories 06-06-00010 Compound microscope; wide field 10x eyepieces 4x, 10x, 4x 10 set and 100x objectives, plastic dust cover. 06-06-00011 Microscope; wide field 15x eyepieces 4x, 10x, 40x and 100x 10 set objectives, built- in variable illumination plastic dust cover. 06-06-00012 Colony counter; for student use 3 piece 06-06-00013 Electronic blood pressure meter; use for student. 10 piece 06-06-00014 Sphygmomanometer; use for student 10 piece 06-06-00015 Haemocytometer; for student use 10 piece 06-06-00016 Digital clinical thermometer; use for student 3 piece 06-06-00017 Hot plate w/ thermostat +350°C, 5 magnetic PTFE bars/ 10 set plate 06-06-00018 Water bath, constant temperature, capacity = 20 L 1 piece 06-06-00019 Capillary tube, different sizes, Pyrex 100 piece 06-06-00020 Autoclave, 30 l, 100 - 140 deg.
    [Show full text]
  • 12Th Physics Chapter 3 Test 2 Mcqs+SQ
    SMART TEST SERIES www.notespk.com : [email protected] Name: Subject: Physics-12 Roll # : Unit(s): 14, Class: Inter Part-II Test: Type 3 - MCQs + SQs Test - Marks=30 Date: Time: Q.1 Four possible answers A, B, C & D to each question are given. Circle the correct one. (10x1=10) 1 Two parallel wires carrying curent in the same direction: (A) Have no effect (B) Repel each other (C) Have no field around them (D) Attract each other 2 − 1 − 1 − 1 E S.I unit of E is NC and that of B is NA m then the unit of B is: (A) m − 1s − 1 (B) ms − 1 (C) ms − 2 (D) ms 3 The S.I. unit of flux density is: (A) NA − 1m2 (B) NA − 1m − 1 (C) NAm − 1 (D) NA − 1m 4 The magnetic fore on an electron travelling with 108ms − 1 parallel to a fiedl strength 1 web m − 2 is: (A) 105N (B) 10 − 10N (C) 1.6 × 10 − 11N (D) Zero 5 The e/m of a neutron is: (A) less than electron (B) zero (C) greater than election (D) the same as electron 6 The CRO is used for: (A) Displaying the wave form of frequency (B) Displaying the wave form of given vibration (C) Displaying wave form of given voltage (D) Converting A.C into D.C 7 In order to increase sensitivity of galvanometer the value of C may be: (A) Increase (B) decrease (C) Neither increase nor decrease (D) Remain same. 8 The relation between current I and angle of deflection θ in a moving coil galvanometer is: (A) I ∞ θ (B) 1 (C) I ∞ sinθ (D) I ∞ cosθ I ∞ θ 9 C Galvanometer is sensitive when BAN is: (A) Small (B) Zero (C) Large (D) Negative 10 A proper combination of a galvanometer and a series of resistance acts as: (A) Voltmeter (B) Ammeter (C) Ohmmeter (D) Avometer Q.2 Write short answers of the following questions.
    [Show full text]
  • Measurements of AC Voltage and Current
    AC AND NULL METHOD ANALOG MEASURING INSTRUMENTS EE 306 – SS2016 Prof. Yasser Mostafa Kadah – www.k-space.org Electrodynamic (Dynamometer) Instrument Action of this type of instrument depends upon electromagnetic force exerted between fixed and moving coils carrying current Electrodynamic (Dynamometer) Wattmeter Owing to the higher cost and low sensitivity of dynamometer ammeters and voltmeters, they are rarely used commercially However, electrodynamic or dynamometer wattmeters are important and commonly employed for measuring power in a.c. circuits Fixed coils F are connected in series with the load, moving coil M is connected in series with non-reactive resistor R across the supply Rectifier AC Ammeters and Voltmeters Rectifier is used to convert AC current into unidirectional current Mean value is measured using MC type instrument Main advantage: far more sensitive than other types of AC voltmeter and can be incorporated in universal instruments (e.g., Avometer) Enabling MC instrument to be used in combination with bridge rectifier and suitable resistors to measure various ranges of alternating current and voltage Oscilloscope Oscilloscope is the most important measuring device with graphical display One of the most powerful diagnostic tools Commonly used to measure exact wave shape of electrical signal, including the amplitude and frequency Can also measure quantities such as pulse width, period and rise time, and can compare two signals and measure their relative timing Old technology relied on cathode-ray tube (CRT)
    [Show full text]
  • Desain Avometer
    PRAKTIKUM PENGUKURAN BESARAN LISTRIK Laboratorium Fisika Instumentasi Jurusan Teknik Elektro – Universitas Kristen Maranatha MODUL 2 – DESAIN AVOMETER I. Kompetensi Umum: Mahasiswa mampu merealisasikan AVOmeter dari galvanometer. II. Kompetensi Khusus: 1. Mahasiswa mampu mendesain dan menghitung nilai tahanan yang dibutuhkan dalam membuat AVOmeter. 2. Mahasiswa mampu memperluas jangkauan ukur Ampere dan Voltmeter. III. Alat – alat 1. Resistor 2. Sumber Tegangan DC 3. Sumber Arus DC 4. Miliamperemeter (ammeter) 5. Capit Buaya 6. Semua tahanan yang diperlukan disediakan oleh pratikan Spesifikasi PMMC yang dipakai Meter Im (mA) Rm (Ω) A 500 9,454 B 500 10,454 C 100 83,33 D 100 86,537 E 300 11,67 IV. Percobaan 1. Amperemeter Arus Searah (DC) A. Menentukan besar Tahanan Shunt 1. Tentukan besar tahanan shunt F (RF) yang akan digunakan agar batas pengukuran max adalah 3A! (Sesuai meter yang digunakan.) 2. Rangkai percobaan seperti Gambar 1! 3. Tentukan skala baru pada meter dengan bantuan beberapa nilai pengukuran arus, yaitu: 0.5A, 1A, 1.5A, 2A, dan 2.5A! Stefani Puspa R ( 05’ 051) & Muliady, ST., MT. Page 1 of 3 Agustus 2008 PRAKTIKUM PENGUKURAN BESARAN LISTRIK Laboratorium Fisika Instumentasi Jurusan Teknik Elektro – Universitas Kristen Maranatha B. Shunt Ayrton 1. Hitung nilai Ra, Rb, dan Rc bila diinginkan range pengukuran 1A, 3A dan 5A! (Sesuai meter yang digunakan.) 2. Rangkai percobaan seperti Gambar 2! 3. Tentukan skala baru pada meter dengan bantuan nilai pengukuran yaitu: 0.5A, 1A, 1.5A, 2A, 2.5A Gambar 2 Rangkaian Ayrton Shunt dan 5A! 2. Voltmeter Arus Searah (DC) A. Multiplier (Tahanan Pengali) 1. Tentukan besar tahanan sebagai tahanan pengali (Rs) agar didapat range pengukuran max 24V! 2.
    [Show full text]
  • Question Bank
    Dr. NAVALAR NEDUNCHEZHIYAN COLLEGE OF ENGINEERING Tholudur, Cuddalore (Dt) – 606 303. QUESTION BANK Subject Code/Subject: EC2351/ MEASUREMENTS AND INSTRUMENTATION Name : U.SATHIYABAMA Designation : ASSISTANT PROFESSOR Dept : ECE Semester : VI UNIT I BASIC MEASUREMENT CONCEPTS Measurement systems – Static and dynamic characteristics – units and standards of measurements – error :- accuracy and precision, types, statistical analysis – moving coil, moving iron meters – multimeters – Bridge measurements : – Maxwell, Hay, Schering, Anderson and Wien bridge. PART –A (1 MARK) 1. Which of the following instruments will be used to measure the temperature above 1600 0C. (a) A simple thermometer (b) Electrical resistance pyrometer (c) Thermo-electric pyrometer(d) None of the above 2. Wein bridge finds application in (a) Frequency determination(b) Resistance measurement only (c) Harmonic distortionanalyzer(d) a and c both. 3. The most common method for measurement of low resistance is: (a) Wheatstone bridge(b) Potentiometer method (c) Voltmeter-ammeter method (d) Kelvin's double bridge 4. Moving iron instruments can be used without much error upto a frequency of (a) 50 Hz (b) 100 Hz (c) 1000 Hz (d) 1500 Hz 5. Subtracting 437 ± 4 from 462 ± 4 would yield a result with percentage error-of (a) ±4% (b) ±16% (c) ±8% (d) ±32% 6. The internal resistance of an ammeter should be (a) Very small (b) Medium (c) High (d) Infinity 7. Three resistances have the following ratings (i) 150Ω at 5%(ii)100Ω at 5% (iii) 200 Ω at 5%. The percentage error when all the three are connected in series will be (a) ±(5/3) % (b) ±5% (c)15 % (d) +5% 8.
    [Show full text]
  • Electronics-World-20
    -ctronics World's renownednews section starts on page 4 ELECTRONICS 1 2> 'WORLD 9111117 liECEMBER 2004 £3.25 What is Tetra? Simulating power MosFets part III Mixed spices part II Simulating ideal transformers using OTAs Circuit Ideas Omni directional ferrite rod receiver Lightbulb protector Pump monitor Simple low -profile High efficiency white LED charge pump Simple capacitor checker WiFiantennae Dual rate thermostat Two wire flow control Precision A -weighting filter ti Quality second-user test it measurement equipment Telnet ,En ENI 550L Amplifier (1.5 to 400MHz) 50 Watts £2500 Hewlett Packard 3314A Function Generator 20MHz £750 Radio Communications Test Sets Hewlett Packard 3324A synth. function/sweep gen. (21MHz)£1950 Agilent (HP) 8924C (opt 601) CDMA Mobile Station T/Set £8500 Hewlett Packard 3325B Synthesised Function Generator £2500 Agilent (HP) E8285A CDMA Mobile Station T/Set £8500 Anritsu MT8802A (opt 7) Radio Comms Analyser (300kHz-3GHz) £8500 Hewlett Packard 3326A Two -Channel Synthesiser £2500 Hewlett Packard 8920B (opts 1,4,7,11,12) £6750 H.P. 4191A R/F Imp. Analyser (1GHz) £3995 Hewlett Packard 8922M + 83220E £2000 H.P. 4192A L.F. Imp. Analyser (13MHz) £4000 Marconi 2955 / 2955A from £1250 tr Hewlett Packard 4193A Vector Impedance Meter (4-110MHz) £2900 Marconi 2955B/60B £3500 Hewlett Packard 4278A lkHz/1MHz Capacitance Meter £3500 Marconi 2955R £1995 H.P. 53310A Mod. Domain Analyser (opt 1/31) £3950 Motorola R2600B £2500 Hewlett Packard 8349B (2 - 20 GHz) Microwave Amplifier £2000 Racal 6103 (optsl, 2) £5000 Hewlett Packard
    [Show full text]
  • The University of Reading Department of Physics
    The University of Reading Department of Physics Experimental Physics 1 An instruction manual to accompany module PH1004 Copyright 1996-2005 Department of Physics, The University of Reading All rights Reserved Last Revised August 2005 University of Reading Department of Physics Contents Disclaimer and Safety Assessment .........................................................................................................2 Chapter 1 Introduction to Experimental Physics ..........................................................................3 Chapter 2 Assessment .......................................................................................................................5 Chapter 3 Specimen Experiment - Charge Transport in Materials ..............................................8 Chapter 4 Statistics..........................................................................................................................17 Chapter 5 Introduction to Skills Sessions .....................................................................................19 Skills Session 1 Data Collection......................................................................................................20 Skills Session 2 Graph Plotting.......................................................................................................23 Skills Session 3 Uncertainties and Errors .....................................................................................31 Skill Sessions 4 Electronic Instrumentation..................................................................................39
    [Show full text]