Culligan Carbon Filter Comparison Chart Culligan CAAP Program Version 8.8 (2009) October

Total Page:16

File Type:pdf, Size:1020Kb

Culligan Carbon Filter Comparison Chart Culligan CAAP Program Version 8.8 (2009) October

Culligan Carbon Filter Comparison Chart Culligan CAAP® Program Version 8.8 (2009) October 12, 2009

Taste, Odor & Dechlorina ASME Tank BW Flow, Tank Size, Media Qty, Width, in Height, in Ship Wt, Oper Wt, Product Line Model Organic tion Flow, Height Service, in Drain, in Depth, in Constr (6) gpm in ft³ (4) (5) (3) lbs lbs Flow, gpm gpm (2) Adder (1) Hi-Flo 22 FRP CF-12 [email protected] 8@1 8 12x52 N/A 1.5 1 2 12 59 17 175 230 Hi-Flo 22 FRP CF-14 [email protected] [email protected] 10 14x47 N/A 1.5 1 3 14 75 19 240 365 Hi-Flo 22 FRP CF-16 7@1 14@2 15 16x53 N/A 1.5 1 3 16 75 21 275 465 Hi-Flo 22 FRP CF-21 12@2 24@7 25 21x62 N/A 1.5 1 6 23 76 26 530 635 Hi-Flo 42F FRP HRF-20 [email protected] 24@4 20 21x62 N/A 2 1.5 6 21 79 21 465 557 Hi-Flo 42F FRP HRF-24 16@2 31@4 30 24x72 N/A 2 1.5 8 24 88 24 555 931 Hi-Flo 42F FRP HRF-30 25@3 49@6 48 30x72 N/A 2 1.5 12 30 96 30 820 1489 Hi-Flo 42F FRP HRF-36 35@3 71@9 70 36x72 N/A 2 1.5 18 36 96 36 1135 2108 CSM ELS CSM-242R 16@3 31@6 30 24x54 4 2 1 8 25 74 33 1048 1465 CSM ELS CSM-302R 25@4 49@7 46 30x60 5 2 2.5 12 31 85 40 1500 2320 CSM ELS CSM-362R 35@3 71@11 69 36x60 7 2 3 18 37 88 46 2760 3745 CSM ELS CSM-422R 48@4 96@13 95 42x60 3 2 3 24 43 90 53 3180 4775 Hi-Flo 50 ELS HR-4825 63@4 126@15 136 48x60 N/A 2.5 3 32 49 93 64 5200 7800 Hi-Flo 50 ELS HR-543 80@6 159@18 160 54x60 N/A 3 3 40 55 96 70 6500 9900 Hi-Flo 50 ELS HR-603 98@1 196@12 210 60x60 N/A 3 3 48 61 98 76 8000 12200 Hi-Flo 50 ELS HR-724 141@5 283@12 270 72x60 N/A 4 3 70 73 106 90 12500 19000 Hi-Flo 50 ELS HR-844 192@6 385@16 400 84x60 N/A 4 4 96 85 111 102 17000 26000

All pressure drop and backwash flow data is based on new media and an incoming water temperature of 60 degrees Fahrenheit. 1) Recommended flow rate and resulting pressure loss shown for taste, odor and organic removal. Maximum flow rate for this purpose should not exceed 5 gpm per square foot of filter area. 2) Recommended flow rate and resulting pressure loss shown for dechlorination. Maximum flow rate for this purpose should not exceed 10 gpm per square foot of filter area. 3) Overall tank height is based on standard non-A.S.M.E. code tank construction. See A.S.M.E. tank height adder column for additional height of A.S.M.E. code tanks. 4) Excludes underbedding. 5) Dimensions do not include space for maintenance. It is recommended that 24 in of free space be provided above the filter for access into the tank and for removal of the tank distribution system if required. 6) ELS: Epoxy Lined Steel, FRP: Fiberglass, TH: Tripl-Hull®, QH: Quadra-Hull™

Recommended publications