Laboratory Instruments needed for

Faculty of Medicine

Country No Description Qty of origin 1. Small centrifuge, with rotor for blood collection and urine tubes 2 Japan, EU,  Power supply 240 V USA, Far  Frequency 50 – 60 Hz east  Immunity EN 61000-6-1  Max. capacity 8 x 15 ml  Max. RPM 6,000 – 8,000 min  Max. RCF 3,461 or 6,153  Running time 1 – 99 min , continuous run, short cycle mode (impulse key)  Frequency drive  Imbalance switch-off  Dimensions (H x W x D) 216 x 231x 292 mm 2. Laboratory Trolley 5 Japan,  Chemical resistant. EU, USA  Suitable for research, medical, industrial and education labs.  Lightweight, easy to clean.  Have a safe working load of approx 250kg  Supplied with precision bearing castors including 2 brakes.

3. Digital magnetic stirrer with heating 2 Japan, EU, USA  LED Digital Multi-point Magnetic Hotplate Stirrer  Display target and actual temperatures  External temperature sensor , display and control actual medium temperature, control accuracy of ±1°C.  Separated safety circuits, fixed safety temperature of 580°C.  Automatically stops heating once exceed secure temperature  HOT warning indicates residual hotplate temperature.  LCD display would show Hot when hotplate temperature over 50°C warning point, even if switched off.  Up t0 .5 L stirring capacity per point  Digital timer function . 4. Differential counter 2 Japan, EU,  Manual differential counter with 8 keys USA, Far  WBC Maturation series Picto-strip east  All metal case  Full white blood cell maturation strip chart  Dual reset knobs  Stable and wide base with rubber feet  Signal bell for counting 100 cells

1 5. Hematology analyzer 1 Japan, EU,  Principles: Flow Cytometry (FCM), Semi-conductor Laser scatter, chemical USA, Far dyemethod, independent Basophil channel Impedance method for WBC, RBC, PLT east counting Cyanide-free reagent for Hemoglobin test.  Parameters:27: WBC, Lym%, Mon%, Neu%, Eos%, Bas%, Lym#, Mon#, Neu#, Eos#,Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, LIC%, LIC#, ALY%, ALY.  3 histograms and 1 scattergram.  Throughput: Up to 60 samples per hour  Sample Volume: Whole Blood: 20 µl, Prediluted: 20 µl  Test Mode: CBC CBC+DIFF  Data Storage Capacity: Up to 40,000 results including numeric and graphical information  Communication: LAN Port supports HL7 protocol  Operating Environment: Temperature: 15°C~30°C, Humidity: 30~85%, Air Pressure: 70~106 kPa  Power Requirement: A.C 100-240V = 300VA 50/60Hz  Supports both whole blood and capillary blood samples  Windows software with at least 40,000 storage for patient results and 60 files for QC data  Customization on reference range, auto-cleaning schedule and report format  Support bi-directional LIS connection

6. Two-channel Blood Coagulation Analyzer 1 Japan, EU, USA, Far east  Number of Channels 2 , 37℃±0.2℃

 Reagent Storage 4  Sample Preparation Positions 6, 3 with timer  Reagent Volume 100μl  Stray ≤1%  Interchannel Error ≤3%  Linearity Error ≤1%

7. Micropipette fixed 200 µl (eppendorf) 10 EU, USA

8. Micropipette fixed 1000 µl (eppendorf) 10 EU, USA

9. Micropipette 1-10 µl (eppendorf) 10 EU, USA

10. Micropipette 10-100 µl (eppendorf) 10 EU, USA

11. Micropipette 100-1000 µl (eppendorf) 10 EU, USA

12. Micropipette 0.5-5ml (eppendorf) 10 EU, USA

2 13. Ophthalmoscopes 2 Japan, EU,  Halogen HPX® lamp illumination for true tissue color USA, Far  18 aperture/filter combinations for greater versatility east  Polarizing filter virtually eliminates corneal reflection  Detect corneal abrasions with the cobalt blue filter  Compatible with all 3.5 V power sources

14. PH meter 2 Japan, EU, USA  Range (PH): -2.00 to 16.00  Range (mV): ± 2000  Range (Temperature °C): -10 to 110  Resolution (pH): 0.1/0.01  Resolution (Temperature): 0.1  Resolution (mV): 0.1/1  Accuracy (pH): ±0.01 pH  Accuracy (Temperature): ±0.5°C  Automatic temperature compensation (ATC) maintains reading accuracy.  Five-point pH calibration, with automatic buffer recognition for both USA (pH 1.68, 4.01, 7.00, 10.01, 12.45) and NIST (pH 1.68, 4.01, 6.86, 9.18, 12.45) pH buffers.  Universal 110/240 VAC power supply and adapters.

15. Laboratory Refrigerator 2 Japan, USA,  32-3/4’ wide Far east  Upfront temperature controls  Adjustable spill-resistant shelves  Adjustable-humidity drawers  Temperature Management Features: Air Tower in Freezer  Defrost Type: Frost Free  Door locker

16. Rotator Instrument for haematology 1 Japan, EU, USA • Speed range: 1 to 40 rpm • Capacity: 12 x 50ml, 20 x 15 ml or 48 x 2.0ml • Timer: 1 Sec. to 9 hour or continues • Dimensions (w x d x h): 21 x 27 x 32 cm • Operating Temp. Range: +4°C to +60°C • Power: 100 to 240V, 50-60Hz, 25W

17. Biochemistry Analyzer 2 Japan,

3 EU,  Wavelength Range 340nm~750nm USA, Far  Measurement Range 0.000~3.000Abs East  Repeatability ≤0.005Abs  Linearity ≤±1%  Cross-contamination ≤1%  Temperature Accuracy ±0.2℃  Test Method :Absorbency , End-point, Kinetic, Two-point, Standard Curve, Control Tube, Factor  Colorimetric Pool Titanium alloy  7.5” colorful touch screen, can be connected to a mouse, Windows operating interface.  Can store 200~500test results.  Can show real-time reaction curve, and print calibration curve, kinetic reaction curve, quality-control curve and general report.  While not working, the instrument will automatically enter half-voltage sleep status to save energy .

18. Vortex mixer 5 Japan, EU, USA  Speed range: 100 to 3000 rpm  Power: 220 V/ 50 Hz  Touch (continuous) and hand-free operation  Suction cups or rubber pad

19. Water bath with Lid 2 Japan, EU, USA  Capacity: from 6 to 15L  Temperature range Ambient: +5°C to 99.9°C  Temperature stability: +/- 0.5C  Internal dimensions (w x d x h),mm: 300 x150 x 200 or 300 x 325 x 200  Overall dimensions (w x d x h), mm: 335 x 230 x 280 or 335 x 408 x 280  Heater Power: From 500W to 1000W  Electrical supply 230V, 50Hz

20. 2 Bodies Mortuary Freezer 3 Japan, EU, USA  High accuracy temperature control system to keep the temperature inside the or Local refrigerator accurate and stable at -5 to 5 C  The set point can be adjusted and corrected with a correctness range of 0.5 C  Safe control system  Safe door lock mechanism  High efficiency compressor  Temperature can be set manually according to demand  Tray size: 190X60X40 cm  AC: single phase 220V 50HZ  External height: approx. 205 mm

21. Morgue Trolley 2 EU or  Trolley made of stainless steel Local  Trolley wheels have arrest system  Dimensions (L x W x H): 180 x 70 x 90 cm

4 22. HD LED TV screen 42” 4 Far East  LED backlighting technology  Thinner bezel improves display's aesthetics  RS-232C allows users to lock out external buttons, synchronize multiple displays and remotely power on/off displays  USB media player allows users to view .jpg images  Full 1080p high-definition resolution provides stunning detail  Built-in NTSC/ATSC analog/digital tuner allows for high-definition broadcast capabilities  Built-in, low-profile 10W speakers

23. Data Show Projector 2 Far East

Resolution  1024 x 768 (XGA) or higher

Aspect Ratio  4:3

Color and White  Minimum 3000 lumens or higher Brightness

Lamp Life:  Minimum 6000 hours ECO mode or higher  Minimum 5000 hours Normal mode or higher

Contrast Ratio  Minimum 2000:1

Connectors  1 x HDMI  1 x Input video  1 x S-video  1 x Audio in: (L and R)  1 x USB connector  2 x computer input

Power Supply Voltage  240V,50/ 60 Hz

Noise:

Normal mode  35 – 40 DB

Remote Control  Yes warranty  3Years warranty parts and Labor on site. Special conditions  Bidder must be a listed partner with the mother company

Note : prices of consumable parts must be provided

5 24. Desktop Computer 2 Far East

Desktop Computers specifications. Processor  Intel Core i5-4690 Memory  1x4GB DDR3-SDRAM, Expandable to 32GB.

chipset  Intel Q87 or higher Storages  500GB SATA II Hard disk (7200RPM).  Multi Super Drive. Controllers  (10/100/1000Mbps) Ether Net Interface  Integrated Sound with speakers (External or on the monitor) Expansion & I/O  1x Serial  6xUSB (2.0) two of them front  1xVGA  audio ports  1xLAN  1xPCI,  1x PCI Express x16

Input and Output  20" or higher Color LCD Monitor (Internal Devices POWER supply)  USB Arabic Latin Keyboard  USB optical Scroll Mouse with pad Others  All Drivers that supports win 7 or higher must be delivered with the Systems on CD-Media.  Micro or Mini Tower case.  All peripherals must have the same brand name (Case, Mother Board, Monitor, KB, Mouse) warranty  3Years warranty parts and Labor on site. Special conditions  Bidder must be a listed partner with the mother company

25. Educational Microscope 1 Japan,

6 EU, USA  High-intensity LED Eco-illumination  Camera compatibility: A digital camera can be attached when the trinocular eyepiece tube is used.  Series objective lenses for flat images 4x, 10x, 20x, 40x, 60x, 100x (Oil)  Trinocular eyepiece tube allows image capturing  Observation methods: Bright-field, Dark-field, Phase contrast with required accessories (Phase contrast attachment, Object marker, Dark-field ring unit, Mirror unit, Cord hanger).  Objectives and sliders dedicated for phase contrast and darkfield observation, even an unstained specimen that is colourless and transparent can be observed with clear contrast.  The condenser comes with an aperture diaphragm with position guide markings for each objective magnification to make operations quick and easy.  Double-plate mechanical stage  Easy halogen lamp replacement  Anti-mold design

26. Cabinets for keeping dry bone samples approx. 190 X90X60 mm (HXWXD) 4 Local

27. Vitek system 1 Japan, EU, USA Automated instrument for ID/AST testing  Automated, efficient, innovative  User-friendly, LIS-compatible VITEK PC software  Vacuum filler, cassette loader, card sealer, reader carousel and waste container all in one small footprint.  Full traceability : the risk of transcription errors is minimized  Complete Testing Menu  Supplemental react file available for customized database entries  Traceability with bar-coded test cards  Test cards – containing 64 wells to ensure accuracy  Enhances workflow, reduces hands-on time & enables rapid reporting • Capable of performing Gram-Negative, Gram-Positive and Yeast Identification and Susceptibility Tests. • Increase work capacity by connecting 2 Reader/Incubator Modules together.  60 card capacity  electrical Power Requirements: • 100/120 VAC (50-60 HZ) • 220/240 VAC (50-60 HZ) • Operating Ambient Temperature Range: 68°F-86°F (20°C to 30°C) • Operating Humidity Range: 20% to 80% relative humidity, non-condensing Altitude: up to 2000 m. Capacity: 60 or 120 cards (2 modules can be connected to the same computer).

7 28. Ultrasonicator 1 Japan, EU, USA  microprocessor based programmable ultrasonic processor.  supplied with probe of 500 microlitre to 50ml capacity  125 W, 110V, 50/60Hz  have frequency at least 20 kHz.  Programmable timer at least for 10 Hours.  Adjustable Pulse on/off should be in range of 1 second to 1 minute.  Programmable operation set time and amplitude for hands free operation.  Pulse mode for prevent heat buildup in temperature sensitive samples.  have elapsed time indicator, displays duration of sonication and real-time energy monitoring  have digital amplitude / intensity control.  Output intensity can be set from 20-100%.  Overload protection prevents damage to circuitry if a fault occurs.  uses lead free components and compact in design.  Should be supplied with: a) Sound abating enclosure b) Laboratory Jack - one c) Stand with converter clamp- one

29. Elisa processor 1 Japan, EU, USA  Processes all ELISA steps, bar-coded reagent traceability (improved accreditation)  A fully automated ELISA Analyzer  For 2 plates with different test combinations on each plate. Multi- well plate (96 well/plate, nonsterile, polystyrene, U- bottom or flat )  No human error in reagent mix-ups  Reagent bottles are directly fitted in the rack without needing to transfer to unnecessary consumables  Easier to maintain : Pipetting, Dispensing, Dilution, Bar Code Scanning, Washing - Detects the following: particulate matter, clots, foam, bubbles - Dilute and dispenses control, calibrators, standards, blanks and samples with a coated stainless steel probe which have level sensing capability - automatically calculates sample results - All human ELISA tests are pre-programmed and additional applications can be added any time. - Self-explanatory software. - A bar code reader and printer are also supplied as part of the system - Biochromatic photometer (405,450, 492, 505, 600 and 630 nm filters) for EIA testing - Calculation modes offered: single point or multipoint calibration, percent absorbance, user programmable factor mode, uptake mode, linear regression. - Switch for 120 or 240 volt 50-60 Hz. 30. Needle incinerator 2 Japan, EU,  Mains Input : 230v, 50Hz / 110v, 60Hz , AC USA, Far  Gauge Of Needles :Can Burn 30 to 20 Gauge East  Destruction Time : approx. 1.5 to 3 Seconds  Burning Temp. : approx. 1400° C to 1800° C

8 31. Phlebotomy chair (for blood collecting) 1 Japan, EU, USA, Far East, Local 32. Haematocrit centrifuge with rotor 1 Japan, EU,  Power supply: 208 – 240 V 1 ~ USA, Far  Frequency 50 – 60 Hz Consumption 270 VA East  Emission, Immunity EN / IEC 61326-1, class B  Max. capacity 20 / 24 capillaries Max. RPM (speed) 13,000 min-1  Max. RCF 16,060 Running time: 1 – 99 min, continuous run,  Dimensions (H x W x D) 228 x 262 x 352 mm 33. Incubator (C02 with shaker) 1 Japan, EU, USA  Temperature Range 4 °C above ambient to 50 °C  Control ± 0.1 °C  Stability ± 0.1 °C at 37 °C  Uniformity (on platform) ± 0.25 °C at 37 °C  (ambient temperature between 18 and 25 °C)  CO2 0.2 to 20 %  Orbit 2.5 cm (1 in)  Shaking speed 25 - 400 rpm  Dimensions  Platform 612 x 356 mm (24 x 14 in)  Overall (W x D x H) 834 x 730 x 848 mm (32.8 x 28.7 x 33.4 in)  Net weight 152 kg  Ports 25 mm access port for instrumentation/  probes, USB for communication/data logging  Included accessories Stainless steel humidity pans, removable  Data logging Optional BioCommand® SFI software for data logging and reports

34. Haemoglobin Meter 1 Japan, EU,  Test Item Haemoglobin(HGB) USA, Far  Test Method High ferricyanide East  Wavelength 540nm  Displayed Number Three-digit number  Measurement Range 0~200g/L  Dilution Ratio 1:251 1:501  Sample Volume 2ml±10%  Test Time ≤8s  Linearity Error >100g/L±3g/L: >100~200g/L±3%

35. Urine Chemistry Analyzer 1 Japan,

9 EU,  Test items: GLU, BIL, KET , SG , BLO, PRO, URO, NIT and LEU USA, Far  Working wavelength 557nm, 610nm and 660nm East  Test speed of single step running mode 60/h  Test speed of continuous running mode 210/h  Data storage: no more than 100 samples  Printer internal high-speed thermal printer  UserInformation :Year , month, day , week, time, sample number and sample code

 Environmental Temperature 10℃-40℃

 Relative Humidity: ≤75%  Power Supply: 220×(1±10 %)V,50×(1 ±2 %)Hz  Input Power: ≤30×(1+15%0)V A  Dimensions: 365 x 233 x 135 (mm)  Weight 3.5 (kg)

36. Laboratory stool 260 Japan, EU,  Adjustable Solid wood seat USA, Far  Adjusted from 18-1/4” to 29-1/4”H in 1-1/2” increments East,  The frame is sturdy , black powder-coated steel Local  The 1 thick seat is 12-1/4” in diameter  300 Ib weight capacity

37. Incubator 1 Japan,  Adaptive multifunctional digital PID-microprocessor controller with high-definition EU, USA TFT-colour display  Temperature: 1 Pt100 sensor DIN class A in 4-wire-circuit  Timer: Digital backwards counter with target time setting, adjustable from 1 minute to 99 days  Set temperature range in °C: min. 5°C above ambient up to +80°C  Resolution of display for setpoint and actual temperature values: 0.1°C  Interior dimension: w x h x d: 560 x 480 x 400 mm  Volume 108 L  Max. Loading of chamber: 175 kg  Exterior dimension; W x h x d: 745 x 864 x 584 mm  230 V, 50/60 Hz / approx. 1400 W * EU: European countries

** Far East: China, Hong Kong, North and South Korea, Indonesia, Malaysia, Singapore, Thailand, Taiwan and the Philippines.

10 السادة ...... المحترمين

( ...... ) مممم ممم

( ...... ) مممم ممم

،تحية طيبة وبعد

فأشير إلى العطاء (2015/38) الخاص بتوريد وتركيب وتشغيل وصيانة أجهزة ومعدات لحاجة مختبرات كلية الطب في الجامعة المركز .

أرجو الخذ بعين العتبار مم م مم ممم ممم مم بالنسبة للبند رقم (15)( Laboratory Refrigerator) المطلوب هو ثلجة مختبر (مخصصة للمختبرات) تحتوي على رفوف وأدراج مقاومة للرطوبة ( (Adjustable – Humidity Drawers وعلى ان تحتوي الثلجة على فريزر ليسمح بتجميع الثلج بداخله Defrost (frost Free) ، وبالنسبة للرقم '3/4-32 فهو يدل على حجم الثلجة.

،،،وتفضلوا بقبول فائق الحترام

.مممم/ مممم ممممم مممممممم مممممممم

11