Me 365 Experiment 5 First Order System Identification Applied to Temperature Measurement Systems

Total Page:16

File Type:pdf, Size:1020Kb

Me 365 Experiment 5 First Order System Identification Applied to Temperature Measurement Systems ME 365 EXPERIMENT 5 FIRST ORDER SYSTEM IDENTIFICATION APPLIED TO TEMPERATURE MEASUREMENT SYSTEMS Objectives: In this two week experiment, we will gain familiarity with first order systems by using two commonly used temperature transducers. The transducers are the copper-constantan (T-Type) thermocouple and the platinum resistance temperature detector (RTD). A common step in the design process for most mechanical systems is to select appropriate sensors based on their performance characteristics. Here, we will be examining a few measures of static and dynamic performance associated with the thermocouple and RTD. If these were part of a complete design project that required temperature measurement, we could then use this information, along with factors such as cost and durability, to choose the best sensor for the job. After completing this lab you should be able to: • Perform a static calibration on a simple temperature transducer. • Experimentally determine static performance characteristics and understand what they mean. • Use two different methods to experimentally determine the time constant of a first order system and understand the significance of the time constant. Procedure: Static Calibration (First Week): We will begin our study of the static and dynamic performance characteristics of the thermocouple and RTD sensors by calibrating both instruments. You should have access to the following equipment to perform this experiment: Copper-Constantan Thermocouple (TC) Platinum Resistance Thermometer (RTD) Glass Thermometer Hot Plate Beaker Dewar Flask 6 Volt Battery Wheatstone Bridge Patchboard 2 - 5 K• , and 1 - 124 • resistors BNC Shunt Rubber Bands Crushed Ice and Distilled Water 1 Laboratory 5 First Order Systems and Temperature Measurements ME 365 Carefully bundle the TC, RTD, and thermometer together with a rubber band. Take care not to bend the TC or RTD leads when handling them. At this time, prepare an ice bath by packing the Dewar flask with ice, and adding distilled water. We won't be using the ice bath as a temperature reference for the TC, since that is being done with an integrated circuit in the ADC interface, but we will take measurements at the ice point for the calibration curve. To ensure that the RTD's output voltages lie within the specified ±20 mV ADC range, the temperature extremes must be measured. Immerse the sensor bundle in the ice bath and observe the RTD's output voltage on the DMM. Then immerse the sensor bundle in a beaker containing a small amount of boiling water and again observe the output voltage. Adjust the potentiometer on the Wheatstone Bridge so that these voltages, representing the extremes of the test, lie within the specified range. Connect the TC output to channel 1 on the ADC interface. Connect the output of the RTD/Wheatstone Bridge to channel 3. Since both of these signals are quite small (on the order of millivolts), we will correct for any bias in the ADC amplifier by subtracting off the bias voltage measured across a shorted input. Short out channel 4 with the BNC shunt to provide a measurement of the ADC bias. The VI will perform the subtraction automatically. Launch LabVIEW then load and run LOGGER.VI from the ME365 library (Desktop\ME365\me365.llb). You will be asked to specify a file name to store your calibration results under. Immerse the sensor/thermometer bundle into the beaker with a small amount of boiling water. Once the thermometer has settled at the boiling point, enter the observed temperature in the "Thermometer Reading" box and press the ENTER button 5 times on the panel to record the data point. At this point, turn off the heating element and begin gently adding chilled distilled water to slowly lower the boiling water down to freezing. The water in the beaker should be cooling down at this point. Using the VI, record the TC and RTD signals for a variety of temperatures ranging up to the boiling point. Try to capture temperatures every 10°C or so. Once again, you should attempt to make multiple recordings, at least 5 recordings, at each temperature of interest. When you have reached the freezing point, begin warming the liquid and collecting data points at the same temperatures you recorded going downscale. The VI does not actually save your data until you halt the VI properly by pressing the STOP button on the front panel. It is a good idea to save your data before proceeding. 2 Laboratory 5 First Order Systems and Temperature Measurements ME 365 Repeat this procedure once more by heating the fluid from freezing to boiling then back to freezing. This concludes the experimental portion of the first laboratory session. You should spend the remainder of your lab time making sure that you have a complete set of usable data, and preparing your static performance analysis for the following week. Static Calibration Deliverables: The following should be submitted at the beginning of the next laboratory session: • Plots of your calibration curves, • Calibration equations for the TC and RTD using linear regression analysis, • A table summarizing the static performance characteristics for the two sensors including: sensitivity, bias, maximum nonlinearity (% FSD), maximum hysteresis (%FSD), R2 , 99% confidence interval of the slope and intercept (from calibration equation), and input resolution. * Note that the ADC input range used by Logger.VI is ±.02 Volts • and the answers to the following questions. Q1) Based on the results of your static performance and linear regression analyses, is a linear calibration curve appropriate for the RTD? Is it appropriate for the TC? Why or why not? Q2) Based on the static performance characteristics you've identified, which sensor would you select for accurate measurement of slowly varying temperatures? Why? 3 Laboratory 5 First Order Systems and Temperature Measurements ME 365 Dynamic Response (Second Week): During the second lab session, we will evaluate the dynamic performance characteristics of the TC and RTD sensors. Set up the equipment as you did in the previous laboratory, and load the multichannel scan VI used at the end of Lab 3. Bring the beaker of water to a boil in preparation for step response testing, that is, carefully plunging the sensor into the beaker of boiling water. An ice bath will be helpful for cooling the sensor before repeating the step response test. You will need to experiment with the VI panel settings (i.e. sample rate, number of samples, input range, etc.) to determine which are best for capturing the dynamic response of the two sensors. It is suggested that you first try sample rates of 30 and 3000 samples per second for both the RTD and thermocouple. When you are confident that you have produced a useful step response, click on the file switch to record the step response data. Save step response curves for both the RTD and TC. Dynamic Response Deliverables: Prepare plots of your step response curves for both sensors. You will need to apply the calibration equation you calculated in the previous week to produce a plot using proper engineering units. Use the techniques for identifying first order system parameters presented in the lecture notes to find the time constants of the RTD and TC. Present both of your plots and calculations along with well thought answers to the following questions: Q3) Based on the results of your system identification analysis, are the RTD dynamics described by a 1st order system? How about the TC dynamics? Why or why not? Q4) Based on the dynamic performance characteristics you've identified, which sensor would you select for accurate measurement of quickly varying temperatures? Why? 4 Laboratory 5 First Order Systems and Temperature Measurements ME 365 Q5) Briefly discuss any discrepancies between Q2 and Q4. 5 Laboratory 5 First Order Systems and Temperature Measurements ME 365 Appendix A: Temperature Measurement Devices We will be studying two types of temperature measuring devices in this laboratory, the T-type thermocouple and the platinum resistance temperature detector (RTD). Keep in mind that there are many other useful devices for obtaining practical engineering temperature measurements, for example, the thermistor. This appendix describes the basic principles which govern the behavior of thermocouple and RTD sensors. The Thermocouple In 1821, Thomas Seebeck made the discovery that when two wires composed of dissimilar metals are joined at both ends and one of the ends is heated a continuous current will flow through the wires [1]. If this thermo-electric circuit is broken, the net open circuit voltage is a function of the junction temperature and the composition of the two wires. This potential is the Seebeck voltage, and it is the underlying physical principle used to make thermocouple based temperature measurements. Three basic laws govern the behavior of thermocouples [2]. They are: 1. The law of homogeneous metals states that a thermo-electric current cannot be sustained in a circuit of a single homogeneous material, by the application of heat alone. At least two different materials are required for a thermoelectric circuit. 2. The law of intermediate metals states that the algebraic sum of the thermo-electric voltages in a circuit composed of any number of dissimilar materials is zero if all of the circuit is at a uniform temperature. A consequence of this is that thermocouple wires may be joined by soldering, welding, or clamping without affecting the thermoelectric output as long as the junction is isothermal. 3. The law of intermediate temperature tells us that if two dissimilar metals produce a thermal EMF of E1 when the junctions are at temperatures T1 and T2, and a thermal EMF of E2 when the junctions are at T2 and T3, then the EMF produced when the junctions are at T1 and T3, will be E1 + E2.
Recommended publications
  • Solutions for Primary & Secondary Laboratories
    1 üThe Source for Calibration Professionals Solutions for Primary & Secondary Laboratories Temperature Calibration Equipment & Services - Required calibration point for range Copper Freeze 1084.62ºC Point Cells COPPER FREEZES 1064.180ºC GOLD FREEZES Silver Freeze Point Cells 961.7800ºC Aluminium Freeze Point Cells 660.3230ºC ITL 17705 or 17702C or 17705 ITL hermometer 962 & 96178 & 962 hermometer T Zinc Freeze Point Cells 419.5270ºC ITL 17702B or ITL 17706 ITL or 17702B ITL Tin Freeze Point Cells 231.9280ºC 465 Indium Freeze 156.5985ºC hermocouple Point Cells ITL 17707 or 17702A or 17707 ITL T hermometer 909 & 670 & 909 hermometer T ITL 17701 ITL ITL 17703 ITL emperature Standard Platinum Resistance Resistance Platinum Standard emperature T Gallium Melt Point Cell & Apparatus 29.76460ºC Gold / Platinum Platinum / Gold High Triple Point Water Cell & Apparatus 0.010000ºC Mercury Triple Point Cell & Apparatus -38.83440ºC Boiling Point -189.3442ºC Standard Platinum Resistance Resistance Platinum Standard Comparator for TRIPLE POINT OF ARGON Argon, Nitrogen or Oxygen -218.7916ºC TRIPLE POINT OF OXYGEN -248.5939ºC TRIPLE POINT OF NEON -259.3467ºC TRIPLE POINT OF HYDROGEN -273.1500ºC Isotech ITS-90 ABSOLUTE ZERO ITS-90 Metrology Temperature Acceptable Furnaces Scale Thermometer Ranges For full details, contact Isothermal Technology Limited, Pine Grove, Southport, Merseyside PR9 9AG England Telephone +44 (0)1704 543830 Fax +44 (0)1704 544799 Email [email protected] Web www.isotech.co.uk Contents Metrology Instruments .........................................Inside Front The Best Comparison Calibration Equipment ........... 54 - 55 Introduction .................................................................. 4 - 5 Nitrogen Boiling Point Apparatus .................................. 57 Model 461 Simple Liquid N2 Apparatus ........................ 58 Primary ITS-90 Standards Model 459 Cryostat ....................................................
    [Show full text]
  • Resistance Thermometers Tailor-Made Sensors. Worldwide
    Resistance thermometers Tailor-made sensors. Worldwide. TAILOR-MADE SENSORS Place of location ➜ 01. ░░░░░░░░░░░░░ EPHY-MESS SENSORS ADD EFFICIENCY AND SAFETY TO YOUR SYSTEM Globality and loyalty to location EPHY-MESS GmbH is a competent solution partner of all manufac- cision products and solutions, innovative engineering and continuous turers of electrical machines and drive technology. As a medium-sized exploratory urge. family owned company, we consult, develop and produce for our cus- tomers individual sensor solutions for safety and control requirements. Always anchored in the vicinity of Wiesbaden, EPHY-MESS has, since the turn of the millennium, risen to become a global provider As a premium manufacturer and distributor of tailor-made industrial which now supplies markets in over 40 countries at an export ratio measurement and sensor technology, the company has taken a lead- of 40 percent. ing position in Germany in its more than 60-year history through pre Yours Claudia & Andreas Becker 2 | Resistance thermometers EPHY-MESS GmbH Rev. 20180108 EPHY-MESS GmbH Resistance thermometers | 3 „Schrift“ > „Sonderzeichen einfügen“ > „Marken“ > „Aktuelle Seitenzahl“ „Schrift“ > „Sonderzeichen einfügen“EPHY-MESS > „Marken“ GmbH > „Aktuelle Lieferprogramm Seitenzahl“ | 3 02. HOW TO CONTACT EPHY-MESS EPHY-MESS GmbH, Berta-Cramer-Ring 1, 65205 Wiesbaden Content Telephone +49 6122 9228-0 [email protected] Fax +49 6122 9228-99 www.ephy-mess.de 03. CONTENT Page Page ➜ CERTIFIED ACCORDING TO Tailor-made sensors 12. Slot resistance thermometers NWT bifilar 24 ░░░░░░░░░░░░░ 01. Globality and loyalty to location 03 13. Slot resistance thermometers NWT chip 34 02. How to contact EPHY-MESS, 04 14. Screw-in resistance thermometers LTH 40 certificates, trade associations 15.
    [Show full text]
  • Temperature Sensor Instruction Manual
    TD-1002b INSTRUCTION MANUAL Temperature Sensor Instruction Manual OKAZAKI MANUFACTURING COMPANY Instruction Manual OKAZAKI MANUFACTURING COMPANY 1-3 GOKODORI 3-CHOME, CHUOU-KU, KOBE 651-0087, JAPAN PHONE : 078-251-8200 FAX : 078-251-8210 http://www.okazaki-mfg.com/index.html E-mail : [email protected] Note : 1) All provisions are subject to change without any notice. 2) This manual is prepared with the greatest possible care, but if any problems, please do not hesitate to contact us. OKAZAKI MANUFACTURING COMPANY INSTRUCTION MANUAL TD-1002b Index CHAPTER 1 BEFORE TO USING 2 1.1 ATTENTION TO SAFETY ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 2 1.2 WHEN BREAK DOWN ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 5 CHAPTER 2 INTRODUCTION 6 CHAPTER 3 TEMPERATURE SENSOR OVERVIEW 7 3.1 TYPES OF TEMPERATURE SENSORS ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 7 3.2 MEASUREMENT PRINCIPLE OF THERMOCOUPLE ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 7 3.3 TYPES OF THERMOCOUPLE ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 8 3.4 MEASUREMENT PRINCIPLE OF RESISTANCE THERMOMETER SENSOR ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 8 3.5 TYPES OF RESISTANCE THERMOMETER SENSOR ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 10 CHAPTER 4 PRIOR TO INSTALLATION 11 4.1 TO CHECK ITEMS AFTER UNPACKING ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 11 4.2 PRECAUTIONS FOR STORING THE
    [Show full text]
  • The Platinum Resistance Thermometer
    The Platinum Resistance Thermometer A REVIEW OF ITS CONSTRUCTION AND APPLICATIONS By liodney Price The platinum resistance thermometer is a versatile instrument for temperature measurement in the range from - 200" to 1000°C. It is used both for precision measurements of the highest accuracy and for routine industrial work. This article discusses the development and construction of resistance thermometers and their uses in a wide range of industries. The platinum resistance thermometer-in ment, and where there are several measuring which the principle of measurement is the points and readings are required at one central variation in the resistance of a platinum wire instrument panel. In addition to the measure- as a function of temperature-is generally ment of elevated temperatures, the platinum accepted as the most accurate temperature resistance thermometer is also finding a measuring instrument available. Its sensitivity number of applications where the accurate and reliability are evident from the fact that determination or control of sub-zero tem- it was first used in 1928 to define the Inter- peratures is needed. national Temperature Scale from -190" to The operation of the resistance ther- 660°C and has thus been the primary inter- mometer depends upon two characteristics of national standard for over thirty years. But platinum-first the simple relationship be- it has other advantages that find many and tween its resistance and its temperature, and increasing applications in industry. It is secondly the high purity, stability and particularly suitable where measurements are reproducibility of the specially prepared to be made over a relatively narrow range of platinum employed for this purpose.
    [Show full text]
  • Calibration Solutions for - Temperature Sensors - Infrared Thermometers - Thermocouple Referencing Systems
    2 üThe Source for Calibration Professionals Calibration Solutions for - Temperature Sensors - Infrared Thermometers - Thermocouple Referencing Systems Temperature Calibration Equipment & Services 1300°C 1200°C 1100°C Oberon R Oberon Cyclops 1000°C Pegasus Pegasus R Pegasus 900°C 800°C Medusa 700°C Gemini Jupiter Jupiter Fast-Cal ISOTower 600°C Gemini R Gemini R Medusa 500°C 400°C Quick-Cal Model 975 Model Blackbody QuickCal 300°C Drago Calisto 200°C Europa Venus Oceanus-6 Hyperion 100°C R Hyperion Model 988 Model Isis 0°C -100°C Minimum Calibration Points to Enable Coefficients to be calculated for a Platinum Resistance Thermometer IPRTs Required Points Number of Points Temp > 0°C 0°C and two positive values Rt=Ro(1 + At + Bt2) 3 Temp < 0°C 0°C, two positive values and Rt=Ro[1 + At + Bt2 + C(t-100°C) t3] 4 to > 0°C one negative value ITS-90 Required Points 0.01 – 29.76°C 0.01°C 29.76°C 2 0.01 – 156°C 0.01°C 156°C 2 0.01 – 232°C 0.01°C 156°C 232°C 3 0.01 – 419°C 0.01°C 232°C 419°C 3 0.01 – 660°C 0.01°C 232°C 419°C 660°C 4 0.01 – 962°C 0.01°C 232°C 419°C 660°C 962°C 5 -38 – 29.76°C -38°C 0.01°C 29.76°C 3 -189 – 0.01°C -189°C -38°C 0.01°C 3 Platinum Resistance Thermometer Summary Ta ble of some ITS-90 Fixed Points Identification Substance Te mp.
    [Show full text]
  • Platinum Resistance Thermometer (PRT) Selection Guide
    Platinum Resistance Thermometer (PRT) Selection Guide hken.rs-online.com (Hong Kong (English)) www.rs-components.com (International) Thermocouple & Platinum Resistance Thermometry - At A Glance Discover more at www.rs-online.com 2 Comparison of Sensor Types Platinum Resistance Thermometer Thermocouple Thermistor Sensor Platinum-wire wound or flat- Thermoelement, Ceramic film resistor two dissimilar metals/alloys (metal oxides) Accuracy (typical values) 0.1 to 1.0°C 0.5 to 5.0°C 0.1 to 1.5°C Long term Stability Excellent Variable, Prone to ageing Good Temperature range -200 to 650°C -200 to1750°C -100 to 300°C Thermal response Wirewound – slow Sheathed – slow Exposed tip – generally fast 0.05 to 2.5 secs Film – faster fast 0.1 to 10 secs typical typical 1-50 secs typical Excitation Constant current required None None Characteristic PTC resistance Thermovoltage NTC resistance (some are PTC) Linearity Fairly linear Most types non-linear Exponential Lead resistance effect 3 & 4 wire – low. 2 wire – high Short cable runs satisfactory Low Electrical “pick-up” Rarely susceptible susceptible Not susceptible Interface Bridge Potentiometric input. Cold junction 2 wire resistance 2,3 or 4 wire compensation required Vibration effects/ shock wirewound – not suitable. Film – Mineral insulated types suitable Suitable good Output/ characteristic approx. 0.4 W/°C From 10µV/°C to -4% / °C to 40µV/°C depending on type Extension Leads Copper Compensating cable Copper Cost Wirewound – more expensive Relatively Inexpensive Film – cheaper low cost to moderate Comments and values shown in this chart are generalised and nominal. They are not intended to be definitive but are stated for general guidance.
    [Show full text]
  • Platinum Resistance Thermometry
    NBS MONOGRAPH 126 Platinum Resistance Thermometry Platinum Resistance Thermometry 55fc - John L. Riddle, George T. Furukawa, and Harmon H. Plumb Institute for Basic Standards National Bureau of Standards »>. Washington, D.C. 20234 < i U.S. DEPARTMENT OF COMMERCE, Frederick B. Dent, Secretary NATIONAL BUREAU OF STANDARDS, Richard W. Roberts, Director Issued April 1973 Library of Congress Catalog Card Number: 72-60003 National Bureau of Standards Monograph 126 Nat. Bur. Stand. (U.S.), Monogr. 126, 1 29 pages (Apr. 1972) CODEN: NBSMA6 For sale by the Superintendent of Documents, U.S. Government Printing Office, Washington, D.C. 20402 Price: S2.10, domestic postpaid: $1.75, GPO Bookstore. Stock No. 0303-01052 (Order by SD Catalog No. C13.44:126). Contents Page 1. Introduction 1 2. Background and basic concepts. 1 2.1. Thermodynamic temperature scale 2 2.2. Practical temperature scales 2 3. Platinum resistance thermometer construction 4 4. Using the thermometer 9 4.1. Mechanical treatment of SPRT 9 4.2. Thermal treatment of SPRT 10 4.3. Thermometer immersion 13 4.4. Heating effects in SPRT 13 5. Resistance measurements 17 5.1. Mueller bridge 18 5.1.1. Bridge ratio arms 19 5.1.2. Bridge current reversal 20 5.2. A-C bridge 20 5.3. Potentiometric methods 20 6. Calculation of temperatures from the calibration data and observed resistances 22 6.1. Temperatures from 0 to 630.74 °C 22 6.2. Temperatures belowf 0 °C 24 - 6.2.1. 182.962 °C (90.188 K) to 0 °C (273.15 K) , 25 6.2.2.
    [Show full text]
  • Criteria for Temperature Sensors of Thermocouple and RTD Senor Types
    WHITEPAPER Criteria for Temperature Sensor Selection of T/C and RTD Sensor Types The Basics of Temperature Measurement Using RTDs Bulletin # 8500-917A 248-295-0880 ■ [email protected] ■ www.acromag.com ■ 30765 Wixom Rd, Wixom, MI 48393 USA Contents Preface 3 The Basics of Resistance Temperature Detectors 3 Points of Consideration When Using RTDs to Measure Temperature 6 Temperature Coefficient of Resistance (TCR) and Alpha (α) 6 Sensitivity 9 Accuracy 9 Interchangeability and Conformity (Maintenance Issue) 11 Repeatability 11 Stability/Drift 11 Corrosion and Contamination 12 Shock and Vibration 12 Insulation Resistance 12 Lead-Wire Resistance 12 Self-Heating 13 Meter Loading 14 Packaging and Thermal Transfer 14 Response Time or Time-Constant 14 Seebeck or Thermoelectric Effect 15 Conclusion 15 Temperature Transmitters 16 About Acromag 16 CRITERIA FOR TEMPERATURE SENSOR SELECTION OF T/C AND RTD SENSOR TYPES The Basics of Temperature Measurement Using RTDs Preface This is part two of a three part series that provides information for choosing an industrial temperature sensor from Thermocouple (T/C) and Resistance Temperature Detector (RTD) sensor types. Part 1 of this series took a close look at thermocouples. This part will look similarly at RTDs. After a review of the basic construction of an RTD, we will take look at an RTDs Temperature Coefficient of Resistance (TCR), its sensitivity, accuracy, interchangeability, repeatability, stability and drift, corrosion and contamination effects, shock and vibration effects, insulation resistance, lead-wire resistance, self-heating effects, meter-loading, packaging and thermal transfer considerations, response time, and thermoelectric effects. In part 3 of this series, we will summarize and compare the thermocouple and RTD sensor types, and provide information for selecting the best sensor for a given application.
    [Show full text]
  • Thermocouple Selection Guide
    Thermocouple Selection Guide uk.rs-online.com (UK) www.rs-components.com (International) ! Thermocouple Thermometry - At a Glance C7=75D<?9!C7?C@B!534=7C2!9E<67!D@!<?CE=3D<@?!"!5@F7B<?9 5@=@EB!5@67C2!D;7B>@5@EA=7!5@??75D@BC%!7HD7?C<@?!3?6 GQRLQ!RV[]TJ\RWV! ][JKTN!\NUXNZJ\]ZN! 2XXTRLJ\RWV!?W\N[ 5@>A7?C3D<?9!G<B7C!3?6!534=7C >J\NZRJT0 ZJVPN KPUWNCVKQP!EQNQWT!EQFGU ECDNG! Gzvgpukqp!' Eqorgpucvkpi!Ngcfu EQFG RXE .21¢E!vq!216¢E! Iqqf!igpgtcn!rwtrqug!kpuwncvkqp!hqt!ÕnkijvÖ!gpxktqpogpvu/ 7@B>6B!CD2?52B5 KGE!71695.4)3118* DTKVKUJ COGTKECP IGTOCP DU!GP71695.4)3119* Ycvgtrtqqh!cpf!xgt{!hngzkdng/ DIA6 4@?5E4D@BC!$'% DU2954<!2;63 CPUK0OE!;7/2 FKP!54824!0!54825 RHC!)gzvtwfgf* .86¢E!vq!361¢E! Tgukuvcpv!vq!qknu-!cekfu!qvjgt!cfxgtug!cigpvu!cpf!hnwkfu/ 840516!03<974?7)098=>/8>/8 Iqqf!ogejcpkecn!uvtgpivj!cpf!hngzkdknkv{/!RVHG dgvvgt!hqt $8HBIDJ!0GOMKHRK)0MNNDO!8HBIDJ' " " " 6H 0GOMKDJ)0MLPQALQAL'!>+)/CSALBD' $ $ $ 6H uvgco0gngxcvgf!rtguuwtg!gpxktqpogpvu 8H0O)0MLPQALQAL% RVHG .86¢E!vq!3610411¢E Tgukuvcpv!vq!qknu-!cekfu!qvjgt!cfxgtug!cigpvu!cpf!hnwkfu/! 4<98&)098=>/8>/8 )vcrgf!' ytcrrgf* Iqqf!ogejcpkecn!uvtgpivj!cpf!hngzkdknkv{/ " " " " ; $4OML)0MNNDO!8HBIDJ'!2D)5MLPQ $ $ $ $ ;H Incuuhkdtg! .71¢E!vq!4610511¢E Iqqf!vgorgtcvwtg!tcpig!dwv!yknn!pqv!rtgxgpv!kpitguu!qh 4OML)/CSALBD'!2D)0MLPQALQAL!4)0% )xctpkujgf* hnwkfu/!Hcktn{!hngzkdng!dwv!fqgu!pqv!rtqxkfg!iqqf!ogejcpkecn 840516!03<974?7)840516 /6?7484?7& rtqvgevkqp/ " " " " < $80)8/'!0GOMKDJ)!/JRKDJ'!0)/' $ $ $ $ <H Jkij!vgorgtcvwtg! .71¢E!vq!811¢E Yknn!ykvjuvcpf!vgorgtcvwtg!wr!vq!811¢E!dwv!yknn!pqv!rtgxgpv!
    [Show full text]
  • Solution and Low-Temperature Heat Capacity Measurements
    Calorillleters for Heat of Solution and Low-Temperature Heat Capacity Measurements GEOLOGICAL SURVEY PROFESSIONAL PAPER 755 Calorimeters for Heat of Solution and Low-Temperature Heat Capacity Measurements By RICHARD A. ROBIE and BRUCE S. HEMINGWAY GEOLOGICAL SURVEY PROFESSIONAL PAPER 755 A description of the construction and operation of a calorimeter for determining the heats of solution in aqueous HF or HCl and of a low-temperature heat capacity calorimeter for cp measurements between 10 and 380 kelvin UNITED STATES GOVERNMENT PRINTING OFFICE, WASHINGTON 1972 UNITED STATES DEPARTM.ENT OF THE INTERIOR ROGERS C. B. MORTON, Secretary GEOLOGICAL SURVEY V. E. McKelvey, Director Library of Congress catalog-card No. 72-600115 For sale by the Superintendent of Documents, U.S. Government Printing Office Washington, D.C. 20402 - Price 40 cents Stock Number 2401-2182. CONTENTS Page Page Abstract ___________________________________________ _ 1 Heat of solution calorimeter __________________________ _ 13 Introduction ________________________________________ _ 1 Components ____________________________________ _ 13 Acknowledgments ___________________________________ _ 2 Submarine _________________________________ _ 13 Low-temperature heat capacity calorimeter_____________ _ 3 Calorimeter vesseL __________________________ _ 17 Cryostat components ____________________________ _ 3 Calorimeter top and closure seal ______________ _ 17 Submarine _________________________________ _ 3 Thermometer_______________________________ _ 17 Heater_____________________________________
    [Show full text]
  • Sensors & Instruments Product Guide
    Sensors & Instruments Product Guide RTDs І Thermocouples І Thermistors І Humidity І Assemblies І Transmitters І Monitors І Controllers Minco: Providing Temperature Sensing Solutions for Demanding Applications For nearly 60 years, Minco has been designing and manu- Minco today: global and growing facturing advanced products for some of the world’s most Minco’s engineering and manufacturing facilities employ over demanding applications. Our offering includes temperature 600 people worldwide. More than 300,000 ft2 (27,900 m2) of sensing and control solutions, thermal heating solutions, manufacturing space provides the capacity and infrastructure flex circuit solutions, and integrated products– coupled with to support a variety of applications for global customers in broad assembly capabilities. diverse markets. Sensors Instruments Minco’s seamless operational capabilities allow us to design and manufacture integrated components from prototype to production, which simplifies the supply chain and improves our response time. Flexible Thermofoil™ Heaters Flex Circuits Minco’s products are supported by expert engineering services to help customers plan and integrate Minco components into their products, delivering proven quality and performance in thousands of applications worldwide. Minco is ISO 9001:2008 / AS9100:2009 (Rev.C)/EN9100 / SJAC9100 (Registrar: TÜV) certified and we have the capa- Superior temperature sensing solutions bilities to meet many other quality assurance, process, and Minco works diligently to provide the best temperature product specifications per your requirements. sensing and instrumentation solutions for your application. We have hundreds of off-the-shelf solutions to meet your Minco Fast Facts immediate requirements, and have designed thousands of custom sensing pack- Founded: 1956 ages to seamlessly Organization: Privately held operate in a wide Headquarters: Minneapolis, Minnesota, USA range of applications.
    [Show full text]
  • Standard Platinum Resistance Thermometer Calibrations from the Ar TP to the Ag FP
    NIST Special Publication 250-81 Standard Platinum Resistance Thermometer Calibrations from the Ar TP to the Ag FP G. F. Strouse NIST Special Publication 250-81 Standard Platinum Resistance Thermometer Calibrations from the Ar TP to the Ag FP G. F. Strouse Chemical Science and Technology Laboratory Process Measurements Division Thermometry Group January 2008 U.S. Department of Commerce Carlos M. Gutierrez, Secretary National Institute of Standards and Technology James M. Turner, Deputy Director ii Certain commercial entities, equipment, or materials may be identified in this document in order to describe an experimental procedure or concept adequately. Such identification is not intended to imply recommendation or endorsement by the National Institute of Standards and Technology, nor is it intended to imply that the entities, materials, or equipment are necessarily the best available for the purpose. National Institute of Standards and Technology Special Publication 250-81 Natl. Inst. Stand. Technol. Spec. Publ. 250-81, 79 pages (2008) CODEN: NSPUE2 Errata A single-digit misprint was found in Coefficient A5 in Table 3, printed as -0.61893395 instead of -0.61899395. This publication has been corrected from the original published version of January 2008. (February 2014 correction) 1 Introduction ............................................................................................................................. 1 2 ITS-90 Overview (Ar TP to Ag FP) ......................................................................................
    [Show full text]