Dupont™ Ligasep™ Degasification Technology Brochure

Total Page:16

File Type:pdf, Size:1020Kb

Dupont™ Ligasep™ Degasification Technology Brochure Water Solutions DuPont™ Ligasep™ Degasification technology Reliably and Sustainably producing industrial water Introduction Cutting-edge in design, but simple in operation When industrial equipment is in contact with water used Ligasep modules feature a radial flow design that more effectively in a process or as an ingredient, oxygen and carbon dioxide removes gases and have our advanced skinned membranes in that water cause corrosion. at the core. This next-generation approach prevents seepage Degassing this water is essential, and our Ligasep system does of water vapor across the membrane, removing the necessity so precisely and highly autonomously. for a more expensive water-sealed vacuum pump and reducing the risk of failure. As it generates a deeper vacuum, no additional Compared to large and high-maintenance conventional systems, nitrogen is required to further dissolve the oxygen, saving on Ligasep uses advanced membrane technology to take out all the production of N2 and other scavengers. question marks – consuming less energy and chemicals to give industrial producers a precisely engineered, smaller and cost-effective Ligasep is highly flexible, low on OPEX and capable of fast solution that extends their equipment service life and increases start-ups and seamless adaptation to fluctuating flows. process uptime. Easy to maintain, the system is highly automated so you will not need on-site expertise to supervise it. Should the need arise, our technicians are soon on-site to give it a service. Gas Removal Sealing resin Gas Removal Water Outlet N2 Inlet Degassed Water Water Hollow fiber O2 Sealing resin * Water circulate Gas Hollow fiber alongside the Removal exterior of hollow fibers Water Inlet Ligasep uses an intelligent design with two types of membrane for effective O2 & CO2 removal. Typical application industries • Ultra Pure Water Production • Deoxygenated boiler feed water • Utility water make-up • Adjust pH without chemicals Industrial water Microelectronics Power generation em d ch ical ce an du d e e R n e r g y u s e Degasification A s s s made simple k e s t i a r n d S P H E ro d r u e ct P tion rotec w o l d G n r a e ty ate ili r sustainab Effective degasification in industrial processes with: • Plug & play, scalable modules • Fast start-up and flow-change capability • Ease of operation No freedom from infringement of any patent or trademark owned by DuPont or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate Water Solutions for Customer’s use and for ensuring that Customer’s workplace and disposal practices are in compliance with applicable laws and other government enactments. The product shown in this literature may not be available for sale and/or available in all geographies where DuPont is represented. The claims made may not have been approved for use in all countries. DuPont assumes no obligation or liability for the information in this document. References to “DuPont” or the “Company” mean Have a question? the DuPont legal entity selling the products to Customer unless otherwise expressly noted. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. Contact us at: DuPont™, the DuPont Oval Logo, and all products denoted with ® or ™ are trademarks or registered trademarks of DuPont or its affiliates. dupont.com/water/contact-us Copyright © 2020 DuPont de Nemours Inc. 45-D02532-en.
Recommended publications
  • Application Note 160
    APPLICATION NOTE 160 Degas Options for Sample Preparation Introduction A degas study was conducted to determine the effectiveness 1. Inert environment – shift from of flow versus vacuum degas. An amorphous silica- adsorbed phase to inert. alumina and a microporous zeolite were prepared by both techniques and then nitrogen isotherms were collected 2. Heat – increase the rate. for both materials. The resulting isotherms established equivalence between vacuum versus flow degas. Vacuum versus Flowing Degas Methods In the present study we accept that temperature may be controlled by various methods and that commercial temperature controllers provide repeatable performance. Rather than studying temperature control, this document will evaluate the topic of vacuum versus flowing degas. 1. Vacuum degas utilizes mass action as the only method for shifting the chemical equilibrium. An adsorbed molecule has a concentration on the surface, C and a negligible pressure, P=0 in the vapor phase. The pressure is maintained near zero since the sample is in a vacuum. Heating the sample increases the rate of transfer from the adsorbed molecules to the inert environment. 2. Flowing degas also utilizes mass action Theory by constant inert purge. The desorbed molecules are swept from the system Typical degas options include vacuum or flowing degas. The via the continuous inert gas flow and the basic concept of degas is quite simple. The sample material partial pressure of the desorbed molecules is placed in an inert environment. This inert environment in an inert stream approaches zero in a exploits chemical potential and creates a favorable state for manner similar to the vacuum technique.
    [Show full text]
  • Degas Backfill Gas Selection for Micromeritics Gas Adsorption Instruments
    Application Note 73 Degas Backfill Gas Selection for Micromeritics Gas Adsorption Instruments Introduction adsorbed gas is one type of contaminant that you Specific surface areas and pore volume distribu- wish to remove during degassing, using nitrogen tions are often determined using gas adsorption as the backfill gas partially defeats the purpose of techniques. Prior to analysis, any adsorbed gas or degassing. Obviously, nitrogen is not a true inert vapor phase (such as water or other volatiles) gas when it comes to microporous materials. should be removed from the sample. This process is often referred to as degassing the sample. Therefore, for materials which tend to adsorb nitrogen, helium is a better choice as the backfill Degassing usually involves either heating the gas. Helium adsorption at room temperature is sample or flowing an inert gas across the sample negligible, even in the high energy pores of most during evacuation. In either case, molecules being microporous samples. desorbed from the surface of the sample are removed from the sample tube. After degassing, There are some highly microporous materials in the sample tube can be sealed and removed in one which helium (if used as the backfill gas) is ex- of the following conditions: tremely difficult to remove due to diffusion. Complete removal requires great care as well as • Under vacuum using the TranSealTM, an appa- time-consuming tasks. Otherwise its presence can ratus which is inserted into the sample tube. It severely distort an adsorption isotherm. is designed to close when removed from the degassing port and open automatically when For samples where neither nitrogen nor helium are installed on the sample port, maintaining a ideal, a vacuum-sealed transfer is the most vacuum-tight seal.
    [Show full text]
  • Computer Simulation Applied to Studying Continuous Spirit Distillation and Product Quality Control
    View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by Elsevier - Publisher Connector Food Control 22 (2011) 1592e1603 Contents lists available at ScienceDirect Food Control journal homepage: www.elsevier.com/locate/foodcont Computer simulation applied to studying continuous spirit distillation and product quality control Fabio R.M. Batista, Antonio J.A. Meirelles* Laboratory EXTRAE, Department of Food Engineering, Faculty of Food Engineering, University of Campinas e UNICAMP, Campinas, Brazil article info abstract Article history: This work aims to study continuous spirit distillation by computational simulation, presenting some Received 7 June 2010 strategies of process control to regulate the volatile content. The commercial simulator Aspen (Plus and Received in revised form dynamics) was selected. A standard solution containing ethanol, water and 10 minor components rep- 2 March 2011 resented the wine to be distilled. A careful investigation of the vaporeliquid equilibrium was performed Accepted 8 March 2011 for the simulation of two different industrial plants. The simulation procedure was validated against experimental results collected from an industrial plant for bioethanol distillation. The simulations were Keywords: conducted with and without the presence of a degassing system, in order to evaluate the efficiency of Spirits fi Distillation this system in the control of the volatile content. To improve the ef ciency of the degassing system, fl Simulation a control loop based on a feedback controller was developed. The results showed that re ux ratio and Aspen Plus product flow rate have an important influence on the spirit composition. High reflux ratios and spirit Degassing flow rates allow for better control of spirit contamination.
    [Show full text]
  • Liquid Degassing and Gasification Solutions
    CARBONATION NITROGENATION LIQUID DEGASSING AND DECARBONATION GASIFICATION SOLUTIONS Providing sanitary processing equipment and customized services Since 1885 CO2 Control of Beer Adjust the carbonation level in beer. Sometimes natural fermentation does not create enough CO2 for the end product which impacts taste and the head of a beer. On the same note, removal of excess CO2 in over-carbonated beer is also an easy process. Nitrogenation of Beer There is a niche market for stout beer where nitrogen is added to beer to improve the foam head on top of the beer. Liqui-Cel® Membranes Liqui-Cel membrane contactors are leading gas transfer devices, commonly used in carbon dioxide removal, deoxygenation, nitrogenation and carbonation. Capable of achieving <1 ppm CO2 and <1 ppb O2, they provide precision in gas control. Because of their cleanliness and predictability, Liqui-Cel membranes are the standard degassing technology in ultrapure water applications. Due to the small footprint, lower installation costs and modular nature of the system, they provide flexibility and can be readily expanded to meet growing capacity. Membranes come in multiple sizes so that you can maximize efficiency and performance while taking into account the desired flow rate and footprint requirements. Need more info? Contact your local sales representative or visit our website at www.mgnewell.com. CREATE A SMOOTH BEER—A “KEG” BEER HOW IT WORKS Liqui-Cel membranes use a microporous hollow fiber membrane to add and/or remove gases from liquids. The hollow fiber is knitted into an array and wrapped around a center tube inside of the membrane housing.
    [Show full text]
  • Lateral Degassing Method for Disposable Film-Chip Microfluidic
    membranes Article Lateral Degassing Method for Disposable Film-Chip Microfluidic Devices Suhee Park, Hyungseok Cho, Junhyeong Kim and Ki-Ho Han * Center for Nano Manufacturing, Department of Nanoscience and Engineering, Inje University, Gimhae 50834, Gyongnam, Korea; [email protected] (S.P.); [email protected] (H.C.); [email protected] (J.K.) * Correspondence: [email protected] Abstract: It is critical to develop a fast and simple method to remove air bubbles inside microchan- nels for automated, reliable, and reproducible microfluidic devices. As an active degassing method, this study introduces a lateral degassing method that can be easily implemented in disposable film-chip microfluidic devices. This method uses a disposable film-chip microchannel superstrate and a reusable substrate, which can be assembled and disassembled simply by vacuum pressure. The disposable microchannel superstrate is readily fabricated by bonding a microstructured poly- dimethylsiloxane replica and a silicone-coated release polymeric thin film. The reusable substrate can be a plate that has no function or is equipped with the ability to actively manipulate and sense substances in the microchannel by an elaborately patterned energy field. The degassing rate of the lateral degassing method and the maximum available pressure in the microchannel equipped with lateral degassing were evaluated. The usefulness of this method was demonstrated using complex structured microfluidic devices, such as a meandering microchannel, a microvortex, a gradient micromixer, and a herringbone micromixer, which often suffer from bubble formation. In conclusion, as an easy-to-implement and easy-to-use technique, the lateral degassing method will be a key Citation: Park, S.; Cho, H.; Kim, J.; technique to address the bubble formation problem of microfluidic devices.
    [Show full text]
  • Liquid Sulfur Degassing: Fundamentals and New Technology Development
    LIQUID SULPHUR DEGASSING: FUNDAMENTALS AND NEW TECHNOLOGY DEVELOPMENT IN SULPHUR RECOVERY P.D. Clark, Department of Chemistry, University of Calgary and Alberta Sulphur Research Ltd., M.A. Shields, M. Huang and N.I. Dowling, Alberta Sulphur Research Ltd. and D. Cicerone, Cicerone & Associates LLC. Contact: [email protected] Abstract Liquid sulphur degassing remains an important component of a Claus sulphur recovery system as a result of the need to produce high purity liquid and solid sulphur (< 10 ppmw residual H2S). Importantly, this process must be accomplished without increasing plant emissions. At present, several effective technologies exist for sulphur degassing, mostly based on air sparge of the liquid in a variety of contraptions. These processes produce large volumes of air contaminated with sulphur vapour, H2O, H2S and SO2 which, if compressed back into the air supply systems, cause plugging and corrosion problems. Formerly, the contaminated air was flowed to the incinerator but this practice is calculated to lower total sulphur recovery by as much as 0.1 %. One objective of this paper is to review the fundamentals of sulphur degassing with air explaining how H2Sx is decomposed and why SO2 is always produced when air is used. Secondly, new data on liquid sulphur degassing with solid catalysts will be discussed, and it will be explained how this information could be applied to liquid sulphur degassing both upstream and downstream of the sulphur locks. These adaptations will avoid use of air and should improve overall sulphur recovery as well as achieve sulphur degassing. Lastly, it will be shown that modifications to sulphur condensers throughout the plant may allow simultaneous degassing and, possibly, an increase in overall sulphur recovery.
    [Show full text]
  • The Origin of Titan's Atmosphere: Some Recent Advances
    The origin of Titan’s atmosphere: some recent advances By Tobias Owen1 & H. B. Niemann2 1University of Hawaii, Institute for Astronomy, 2680 Woodlawn Drive, Honolulu, HI 96822, USA 2Laboratory for Atmospheres, Goddard Space Fight Center, Greenbelt, MD 20771, USA It is possible to make a consistent story for the origin of Titan’s atmosphere starting with the birth of Titan in the Saturn subnebula. If we use comet nuclei as a model, Titan’s nitrogen and methane could easily have been delivered by the ice that makes up ∼50% of its mass. If Titan’s atmospheric hydrogen is derived from that ice, it is possible that Titan and comet nuclei are in fact made of the same protosolar ice. The noble gas abundances are consistent with relative abundances found in the atmospheres of Mars and Earth, the sun, and the meteorites. Keywords: Origin, atmosphere, composition, noble gases, deuterium 1. Introduction In this note, we will assume that Titan originated in Saturn’s subnebula as a result of the accretion of icy planetesimals: particles and larger lumps made of ice and rock. Alibert & Mousis (2007) reached this same point of view using an evolutionary, turbulent model of Saturn’s subnebula. They found that planetesimals made in the solar nebula according to their model led to a huge overabundance of CO on Titan. We obviously have no direct measurements of the composition of these planetes- imals. We can use comets as a guide, always remembering that comets formed in the solar nebula where conditions must have been different from those in Saturn’s subnebula, e.g., much colder.
    [Show full text]
  • Click Here for the Latest – All in One Wine Pump Manual –
    All in One Wine Pump Rack-Bottle-Degas-Filter Thank you for purchasing the All in One Wine Pump. We are confident this unit will make racking, bottling, degassing and filtration operations quick, simple and a lot of fun! Family owned and operated, we are dedicated to bringing you a great experience with our quality American-Made product. Customer service is everything to us. If you have any questions, comments or concerns, please contact us at Allinonewinepump.com. You will get a prompt response. –Steve Helsper/ Owner & Creator Table of Contents Section 1: Description of the All in One Wine Pump 1.1 What does it do? 1.2 Receiving your All in One Wine Pump Section 2: Safeguards and Warranty Information 2.1 Safeguards 2.2 Electrical 2.3 Proper Use Conditions 2.4 Warranty Information Section 3: Using the All in One Wine Pump 3.1 Setting up Your All in One Wine Pump 3.2 Cleaning and Sanitizing 3.3 Racking Wine into Glass 3.4 Racking Wine into an Oak Barrel or Sanke Keg 3.5 Bottling Wine 3.6 Degassing Wine 3.7 Filtering Wine 3.8 Filtration Set-up & Process Manual written and designed by: Jeff Shoemaker Section 1: Description of the All in One Wine Pump 1.1 What does it do? All in One Racking, Degassing, Bottling & Filtration. Features Advantages Odorless and oil-free – vacuum wine Decreases racking time pump Better quality wine- less air contact Light weight- approx. 9lbs and well No lifting of heavy carboys balanced No more bending over – for Durable plastic housing is easy to clean transferring or bottling wine, beer and In-line vacuum
    [Show full text]
  • Carbon Dioxide Degassing at the Groundwater
    1 Carbon dioxide degassing at the groundwater-stream-atmosphere interface: 2 isotopic equilibration and hydrological mass balance in a sandy watershed 3 4 Loris Deirmendjian1 and Gwenaël Abril1, 2, * 5 6 1Laboratoire Environnements et Paléoenvironnements Océaniques et Continentaux 7 (EPOC), CNRS, Université de Bordeaux, Allée Geoffroy Saint-Hilaire, 33615 Pessac 8 Cedex France. 9 2Departamento de Geoquímica, Universidade Federal Fluminense, Outeiro São João 10 Batista s/n, 24020015, Niterói, RJ, Brazil. 11 *Now also at Laboratoire d’Océanographie et du Climat, Expérimentations et 12 Approches Numériques (LOCEAN), Centre IRD France-Nord, 32, Avenue Henri 13 Varagnat, F-93143 Bondy, France 14 15 Correspondence to Gwenaël Abril ([email protected]) 16 17 18 Abstract 19 Streams and rivers emit significant amounts of CO2 and constitute a preferential 20 pathway of carbon from terrestrial ecosystems to the atmosphere. However, the 21 estimation of CO2 degassing based on water-air CO2 gradient, gas transfer velocity 22 and streams surface area, is subject to large uncertainties. Furthermore, the isotopic 23 signature of DIC in streams is strongly impacted by gas exchange, which makes it a 24 useful tracer of CO2 degassing, under some specific conditions. For this study, we 25 characterize annual transfers of dissolved inorganic carbon (DIC) along the 26 groundwater-stream-river continuum based on DIC concentrations, isotopic 27 composition and measurements of stream discharges. We selected as a study site a 28 homogeneous, forested and sandy lowland watershed (Leyre River), where 29 hydrology occurs almost exclusively through drainage of groundwater (no surface 30 runoff). We observed a first general spatial pattern of pCO2 and DIC decrease and 31 δ13C-DIC increase from groundwater to stream orders 1 and 2, which was due to a 32 faster degassing of groundwater 12C-DIC compared to 13C-DIC, as verified 33 experimentally.
    [Show full text]
  • Carbon Dioxide Degassing at the Groundwater-Stream
    Journal of Hydrology 558 (2018) 129–143 Contents lists available at ScienceDirect Journal of Hydrology journal homepage: www.elsevier.com/locate/jhydrol Research papers Carbon dioxide degassing at the groundwater-stream-atmosphere interface: isotopic equilibration and hydrological mass balance in a sandy watershed ⇑ Loris Deirmendjian a, Gwenaël Abril a,b, a Laboratoire Environnements et Paléoenvironnements Océaniques et Continentaux (EPOC), CNRS, Université de Bordeaux, Allée Geoffroy Saint-Hilaire, 33615 Pessac Cedex, France b Departamento de Geoquímica, Universidade Federal Fluminense, Outeiro São João Batista s/n, 24020015 Niterói, RJ, Brazil article info abstract Article history: Streams and rivers emit significant amounts of CO2 and constitute a preferential pathway of carbon trans- Received 18 April 2017 port from terrestrial ecosystems to the atmosphere. However, the estimation of CO2 degassing based on Received in revised form 13 November 2017 the water-air CO2 gradient, gas transfer velocity and stream surface area is subject to large uncertainties. Accepted 1 January 2018 Furthermore, the stable isotope signature of dissolved inorganic carbon (d13C-DIC) in streams is strongly Available online 12 January 2018 impacted by gas exchange, which makes it a useful tracer of CO degassing under specific conditions. For This manuscript was handled by L. Charlet, 2 Editor-in-Chief, with the assistance of this study, we characterized the annual transfers of dissolved inorganic carbon (DIC) along the Philippe Negrel, Associate Editor groundwater-stream-river continuum based on DIC concentrations, stable isotope composition and mea- surements of stream discharges. We selected a homogeneous, forested and sandy lowland watershed as a Keywords: study site, where the hydrology occurs almost exclusively through drainage of shallow groundwater (no Groundwater-stream interface surface runoff).
    [Show full text]
  • Instructions: 1 Gallon 4 Week
    INSTRUCTIONS: BE SURE TO USE ALL INGREDIENT PACKAGES INCLUDED IN YOUR KIT. 1 GALLON 4 WEEK Your wine kit includes the following: • Wine Base – unlabeled large bag consisting of grape juice concentrate pLaCe YOuR • Reserve (if included) – smaller bag pROduCtiON • May contain oak (granular or chips). Use all items that are included) COde StiCkeR HeRe iMpORTANT: ensure that your primary fermenter is large enough for the juice bladder • Yeast Pack (Found on the top of with space for foaming during fermentation. • Packet #2 Bentonite – helps yeast activity and removes proteins your wine kit box) • Packet #3 Potassium Metabisulphite – used to prevent oxidation and TIP: One gallon jug filled with water to the bottom of the handle equals 128 fl. oz. improve shelf life • Packet #4 Potassium Sorbate – inhibits yeast cell reproduction • Fining Agents – Kieselsol (up to 2 packages) and Chitosan (up to 2 packages) – Removes suspended particles, which results in a clear stable wine SPECIFIC GRAVITY (S.G.) BY STAGE wineMaking equipMent needed WINE STYLE STARTING S.G. STABILIZING S.G. primary Fermenter: Moscato 1.065 - 1.075 < 0.996 a food grade graduated plastic container up to 1.5 US gal. All others 1.080 - 1.097 < 0.996 glass Jug: a glass jug to hold 1 uS gal. and will fit a STEP 1 DAY 1 - PRIMARY FERMENTATION DAY 1 fermentation lock and stopper. date: MM / DD / YY 1.1 Clean and sanitize equipment to be used. Starting S.g.: 1.2 pour 1 cup of hot tap water into bottom of the primary fermenter or glass one gallon jug Racking tube & tubing: and add packet #2 bentonite.
    [Show full text]
  • Understanding the Formation of CO2 and Its Degassing Behaviours in Coffee
    Understanding the Formation of CO2 and Its Degassing Behaviours in Coffee by Xiuju Wang A Thesis presented to The University of Guelph In partial fulfilment of requirements for the degree of Doctor of Philosophy in Food Science Guelph, Ontario, Canada © Xiuju Wang, May, 2014 ABSTRACT UNDERSTANDING THE FORMATION OF CO2 AND ITS DEGASSING BEHAVIOURS IN COFFEE Xiuju Wang Advisor: University of Guelph, 2014 Professor Loong-Tak Lim In the present study, the effect of roasting temperature-time conditions on residual CO2 content and its degassing behaviours in roasted coffee was investigated. The results show that the residual CO2 content in the roasted coffee beans was only dependent on the degree of roast and independent on the roasting temperature applied. However, CO2 degassing was shown significantly faster (p<0.05) in roasted coffee processed with high- temperature-short-time (HTST) than those roasted with low-temperature-long-time (LTLT) process. Moreover, the CO2 degassing rate increased with the degree of roast. CO2 degassing in ground coffee was significantly faster than in whole beans with the rate highly dependent on the grind size and roasting temperature, but less dependent on the degree of roast. CO2 degassing rate increased with the increasing of environmental temperature and relative humidity. Although CO2 degassing has been a challenging problem in the coffee industry for decades, there is still no clear understanding of precursors of CO2. In the present study, the hypothesis of “chlorogenic acid (CGA) is the principal precursor of CO2” was tested. Although strong negative linear correlation (R2>0.9) between total CGA and residual CO2 content during coffee roasting was detected, and vanishing of IR bands of the C=O group in caffeic acid and quinic acid moieties during heating of pure CGA at coffee roasting temperature was observed, the quantification analysis of CO2 generation from pure CGA heating indicated only ~ 8% yields at 230°C, which led us to conclude that CGA was one of the CO2 precursors but not the principal one.
    [Show full text]