Using Performance Reference Compound-Corrected Polyethylene

Total Page:16

File Type:pdf, Size:1020Kb

Using Performance Reference Compound-Corrected Polyethylene Chemosphere 127 (2015) 10–17 Contents lists available at ScienceDirect Chemosphere journal homepage: www.elsevier.com/locate/chemosphere Using performance reference compound-corrected polyethylene passive samplers and caged bivalves to measure hydrophobic contaminants of concern in urban coastal seawaters ⇑ Abigail S. Joyce a,1, Mallory S. Pirogovsky a, Rachel G. Adams b, , Wenjian Lao c, David Tsukada c, Curtis L. Cash d, James F. Haw a, Keith A. Maruya c a University of Southern California, Los Angeles, CA, United States b Loyola Marymount University, Los Angeles, CA, United States c Southern California Coastal Water Research Project Authority, Costa Mesa, CA, United States d City of Los Angeles Environmental Monitoring Division, Playa del Rey, CA, United States highlights Hydrophobic organic contaminants were measured with polyethylene passive samplers. Seawater concentrations measured up to 1000 pg LÀ1 (p,p0-DDE) & 300 pg LÀ1 (DDNU). Seawater measurements with depth suggest bed sediments were a source of DDTs & PCBs. Co-deployed mussel- and polyethylene-measured concentrations correlated strongly. article info abstract Article history: Low-density polyethylene (PE) passive samplers containing performance reference compounds (PRCs) Received 8 September 2014 were deployed at multiple depths in two urban coastal marine locations to estimate dissolved concentra- Received in revised form 17 December 2014 tions of hydrophobic organic contaminants (HOCs), including dichlorodiphenyltrichloroethane (DDT) and Accepted 19 December 2014 its metabolites, polychlorinated biphenyl (PCB) congeners, and polybrominated flame retardants. PE sam- plers pre-loaded with PRCs were deployed at the surface, mid-column, and near bottom at sites repre- Handling Editor: Caroline Gaus senting the nearshore continental shelf off southern California (Santa Monica Bay, USA) and a mega commercial port (Los Angeles Harbor). After correcting for fractional equilibration using PRCs, concentra- À1 À1 Keywords: tions ranged up to 100 pg L for PCBs and polybrominated diphenyl ethers (PBDEs), 500 pg L for À1 À1 0 Passive samplers DDMU and 300 pg L for DDNU, and to 1000 pg L for p,p -DDE. Seawater concentrations of DDTs Seawater and PCBs increased with depth, suggesting that bed sediments serve as the source of water column HOCs Bivalves in Santa Monica Bay. In contrast, no discernable pattern between surface and near-bottom concentrations PCBs in Los Angeles Harbor was observed, which were also several-fold lower (DDTs: 45–300 pg LÀ1, PCBs: 5– DDTs 50 pg LÀ1) than those in Santa Monica Bay (DDTs: 2–1100 pg LÀ1, PCBs: 2–250 pg LÀ1). Accumulation by PBDEs mussels co-deployed with the PE samplers at select sites was strongly correlated with PE-estimated sea- water concentrations, providing further evidence that these samplers are a viable alternative for monitor- ing of HOC exposure. Fractional equilibration observed with the PRCs increased with decreasing PRC molar volume indicating the importance of target compound physicochemical properties when estimat- ing water column concentrations using passive samplers in situ. Ó 2015 Elsevier Ltd. All rights reserved. 1. Introduction The southern California coastal zone is a densely populated, ⇑ Corresponding author. Tel.: +1 310 338 5186. highly urbanized and industrialized region where the input and E-mail address: [email protected] (R.G. Adams). fate of hydrophobic organic contaminants (HOCs) in the nearshore 1 Office of Research and Development, National Health and Environmental Effects ocean environment remains an issue of concern (Schiff, 2000). This Research Laboratory – Atlantic Ecology Division, US Environmental Protection coastal zone receives discharge of treated wastewater effluent and Agency, Narragansett, Rhode Island, United States. http://dx.doi.org/10.1016/j.chemosphere.2014.12.067 0045-6535/Ó 2015 Elsevier Ltd. All rights reserved. A.S. Joyce et al. / Chemosphere 127 (2015) 10–17 11 stormwater runoff from a population base of more than 10 million 2. Theory people. HOCs that have been deposited in bedded sediments continue to be available to biota in this marine ecosystem At equilibrium, the concentration of a HOC dissolved in water, À1 (Fernandez et al., 2012, 2014). Two of the most prevalent contam- CW (pg L ), can be estimated from the mass of the HOC sorbed inants in the Southern California Bight (SCB), a system that by the PE sampler and the chemical-specific PE-water partition À 1 includes Santa Monica Bay and the Palos Verdes Shelf (PVS), are coefficient (KPEW; Lwater kgPE ). CW is calculated under equilibrium remnants of technical DDT and PCB mixtures (Venkatesan et al., conditions: 1996; Eganhouse et al., 2000). In fact, the U.S. Environmental Pro- 1 CPE tection Agency added the PVS to the National Priorities List and is CW ¼ ð1Þ currently evaluating remediation approaches for the site (EPA, KPEW 2009). More recently, brominated flame retardants have received 1 À 1 where CPE (pg kgPE ) is the HOC concentration sorbed by the PE at attention due to their toxic potential in the aquatic environment equilibrium. PRCs can be added to the PE prior to deployment to (Darnerud, 2008). Polybrominated diphenyl ethers (PBDEs) have assess (and if necessary, to correct for) the extent of equilibrium been detected in virtually all ecosystems and taxa (Covaci et al., achieved (Adams et al., 2007). The PRC will allow for equilibrium 2011) and remain a concern in the SCB region and along the Cali- to be assessed under varying ambient conditions (Booij et al., fornia coast (Dodder et al., 2012; Maruya et al., 2014). Because of 2003). The fractional equilibration (f ) achieved by a PRC can be cal- their persistence and toxicity, PBDEs are being phased out of com- culated as (Fernandez et al., 2012; Friedman et al., 2012): mercial use in the United States (EPA, 2009). t Monitoring to ensure that HOC concentrations are not CPRC f ¼ 1 À 0 ð2Þ approaching harmful levels is an essential component of protecting CPRC the integrity of the nearshore ocean environment. In addition, 0 t exposure risks and emission reduction effectiveness can be where CPRC and CPRC represent the concentration of the PRC prior to assessed by measurement of freely dissolved HOC concentrations and after deployment, respectively. Note that this is a first-order, Ct PRC Àket (Lohmann and Muir, 2010). The state of California has set coastal exponential model (Adams et al., 2007)as1À 0 ¼ 1 À e where CPRC ocean water column guidelines for the DDT metabolite dic- k is a first-order exchange rate coefficient. PRCs are matched to À1 e hlorodibenzoethene (DDE) at 590 pg L and for total PCBs at analytes with comparable physiochemical properties (e.g., molar À1 170 pg L (EPA, 2000). However, achieving such low monitoring volume, diffusivity, partitioning coefficient). Equation (3) below is thresholds is difficult and costly with conventional methods, which 1 thus used to estimate C so that CW may be calculated in Eq. (1), in addition, often cannot achieve the desired detection limits PE (Burgess, 2012). Direct measurement of the freely dissolved water Ct C1 ¼ PE ð3Þ concentration has shown promise in estimating the bioavailability PE f of HOCs (Borga et al., 2005). where Ct , is the target analyte concentration after deployment. The Bivalves have been used to monitor water quality in the U.S. PE since 1975 (Farrington et al., 1983; Goldberg and Bertine, 2000). surface area of the PE deployed can be increased in order to allow À1 Because they are sessile and can filter hundreds of liters of seawa- for very low concentrations (e.g., pg L ) to be detected by the large ter every day, bivalves provide time-integrated measurements of sorbing capacity. chemical concentrations in coastal waters (Goldberg and Bertine, If tissue concentration data are available for sentinel organisms 2000; O’Connor and Lauenstein, 2006). Polymer passive samplers exposed to HOCs in seawater (e.g. sessile bivalves), the bioconcen- À1 that concentrate target analytes such as HOCs from the aqueous tration factor (BCF, L kg ) is defined as phase can serve as alternative water quality sentinels (Gorecki Cb and Namiesnic, 2002; Mayer et al., 2003; Zabiegala et al., 2010). BCF ¼ ð4Þ CW The utility of passive samplers is maximized when operated in À1 À1 equilibrium mode; i.e. when the concentrations in the water and where Cb (ng kg ) is the biota tissue concentration and CW (ng L ) passive sampler has reached steady-state; however, when equilib- is defined above (Arnot and Gobas, 2006). rium is not achieved, performance reference compounds (PRCs) may be used to correct for non-equilibrium (Adams et al., 2007; 3. Materials and methods Booij et al., 2002). Low-density polyethylene (PE) has been success- fully used to measure DDT metabolites and PCBs in seawater 3.1. Materials (Fernandez et al., 2012), and shows promise in measuring PBDEs (Sacks and Lohmann, 2012). Low-density PE sheeting (Covalence, Minneapolis, MN; 25 lm Recently, Fernandez et al. (2012, 2014) measured PCBs and DDT thick) was cut into strips (5 cm  100 cm, 2 g) and pre-cleaned metabolites in PVS seawater using PE and SPME passive samplers in dichloromethane (DCM; 1 day) and methanol (MeOH; 3 days) and reported a gradient emanating from bottom sediments and prior to loading PRCs. PRCs were loaded into cleaned PE in 1.8 L also away from a known area of elevated contamination (a marine of a 4:1 MeOH:water spiking solution containing PCB congeners: 13 Superfund site). In this study we used PE passive samplers, pre- 50, 155, and 184 (Ultra Scientific, N. Kingston, RI, USA) and C12- loaded with PRCs, to measure DDT and its metabolites, PCBs, and p,p0-DDE (99%, Cambridge Isotope Laboratories, Inc., Andover, PBDEs in the coastal ocean and a semi-enclosed embayment (Los MA, USA) for 20 days (Booij et al., 2002). The nominal concentra- Angeles Harbor) to allow for a comparison of PRC kinetics over a tion of each PRC in the spiking solution was 100 lgLÀ1.
Recommended publications
  • Development and Application of Passive Samplers for Assessing Air and Freely Dissolved Concentrations of Hydrophobic Organic Contaminants
    Development and Application of Passive Samplers for Assessing Air and Freely Dissolved Concentrations of Hydrophobic Organic Contaminants by Adesewa A. Odetayo, B.Tech., M.Sc. A Dissertation In Civil, Environmental and Construction Engineering Submitted to the Graduate Faculty of Texas Tech University in Partial Fulfillment of the Requirements for the Degree of DOCTOR OF PHILOSOPHY Approved Dr. Danny D. Reible Chair of Committee Dr. Chongzong Na Dr. Weile Yan Dr. Mark Sheridan Dean of the Graduate School December 2020 Copyright 2020, Adesewa Odetayo Texas Tech University, Adesewa Odetayo, December 2020 Acknowledgements This research was supported by funding from U.S Army Corps of Engineer (USACE) and U.S Army Engineer Research Development Center (ERDC) (contract # W912HZ-17-2-0019), and the Environmental Security Technology Certificate Program (ESTCP) (contract # ER 201735). Special thanks to the crew from ERDC for their support during all the field sampling trips. Firstly, my sincere appreciation goes to my supervisor, Dr. Danny Reible for his help, guidance, and tremendous support throughout the course of my doctoral study, without whom I would have accomplished this milestone. I would like to also extend my gratitude to my committee members for their time and constructive inputs to my research. My Doctoral research experience was made possible because of so many individuals starting with Magdalena Rakowska, who is always available to help and provide intellectual insights pertaining my research. My adopted brother, Uriel de Jesús Garza Rubalcava who cheered me up and always available to help. Tariq Hussain and Alex Smith who I would most likely meet in the Lab at nights or weekends working on their individual research and fellow passive sampling buddy.
    [Show full text]
  • Redalyc.Passive Sampling in the Study of Dynamic and Environmental
    Revista Facultad de Ingeniería Universidad de Antioquia ISSN: 0120-6230 [email protected] Universidad de Antioquia Colombia Narvaez V., Jhon F.; Lopez, Carlos A.; Molina P., Francisco J. Passive sampling in the study of dynamic and environmental impact of pesticides in water Revista Facultad de Ingeniería Universidad de Antioquia, núm. 68, febrero-septiembre, 2013, pp. 147- 159 Universidad de Antioquia Medellín, Colombia Disponible en: http://www.redalyc.org/articulo.oa?id=43029811014 Cómo citar el artículo Número completo Sistema de Información Científica Más información del artículo Red de Revistas Científicas de América Latina, el Caribe, España y Portugal Página de la revista en redalyc.org Proyecto académico sin fines de lucro, desarrollado bajo la iniciativa de acceso abierto Rev. Fac. Ing. Univ. Antioquia N.° 68 pp. 147-159. Septiembre, 2013 Passive sampling in the study of dynamic and environmental impact of pesticides in water Muestreadores pasivos en el estudio de la dinámica de plaguicidas y el impacto ambiental en el agua Jhon F. Narvaez V. *1 Carlos A. Lopez2 Francisco J. Molina P.1 1Grupo de Investigación en Gestión y Modelación Ambiental-GAIA. Facultad de Ingeniería, Universidad de Antioquia A.A. 1226. Calle 67 Nº 53-108. Medellín, Colombia. 2Laboratorio Análisis de Residuos. Instituto de Química. Universidad de Antioquia A.A. 1226. Calle 67 Nº 53-108. Medellín, Colombia. (Recibido el 9 de agosto de 2012. Aceptado el 5 de agosto de 2013) Abstract Pesticides are the most applied substances in agricultural activities which can contaminate water bodies by direct or indirect discharge, but large volumes and natural transformation processes can decrease the concentration of these substances and their degradates in watershed.
    [Show full text]
  • Passive Sampling of Groundwater Wells for Determination of Water Chemistry
    Passive Sampling of Groundwater Wells for Determination of Water Chemistry Chapter 8 of Section D. Water Quality Book 1. Collection of Water Data by Direct Measurement Techniques and Methods 1–D8 U.S. Department of the Interior U.S. Geological Survey A B C D E F H G Cover. (A) Figure 15 from report, AGI Sample Module®. Photograph from Mark Arnold, Amplified Geophysical Imaging, LLC. (B) Figure 11A from report, an EON Products, Inc. Dual Membrane (DM) sampler®. Photograph by Bradley P. Varhol, EON Products, Inc. (C) Figure 7B from report a 2.5-inch-diameter regenerated cellulose dialysis membrane sampler with external supports after assembly. Photograph by Thomas E. Imbrigiotta, U.S. Geological Survey. (D) Figure 17A from report, A downhole semi-permeable membrane device (SPMD) sampler. Photograph and diagram by David A. Alvarez, U.S. Geological Survey. (E) A series of nylon screen samplers retrieved from a profile of the water column of a well showing capped bottles and the removed tops. The variation of iron-staining on the removed tops indicates stratified flow with different redox conditions occurs under ambient flow conditions in the well. Photograph by Philip T. Harte, U.S. Geological Survey. (F) Figure 5A from report, a polyethylene diffusion bag sampler. Photograph by Bradley P. Varhol, EON Products, Inc. (G) Figure 9 from report, a rigid porous polyethylene sampler, without protective mesh and with protective mesh, in a water-filled tube for shipment. Photographs by Leslie Venegas, ALS Global. (H) Figure 13A from report, QED Environmental Systems, Inc. Snap Sampler® with volatile organic compound bottle (40-milliliter vial).
    [Show full text]
  • Preparation and Performance Features of Wristband Samplers and Considerations for Chemical Exposure Assessment
    OPEN Journal of Exposure Science and Environmental Epidemiology (2017) 27, 551–559 www.nature.com/jes ORIGINAL ARTICLE Preparation and performance features of wristband samplers and considerations for chemical exposure assessment Kim A. Anderson1, Gary L. Points III1, Carey E. Donald1, Holly M. Dixon1, Richard P. Scott1, Glenn Wilson1, Lane G. Tidwell1, Peter D. Hoffman1, Julie B. Herbstman2 and Steven G. O’Connell1 Wristbands are increasingly used for assessing personal chemical exposures. Unlike some exposure assessment tools, guidelines for wristbands, such as preparation, applicable chemicals, and transport and storage logistics, are lacking. We tested the wristband’s capacity to capture and retain 148 chemicals including polychlorinated biphenyls (PCBs), pesticides, flame retardants, polycyclic aromatic hydrocarbons (PAHs), and volatile organic chemicals (VOCs). The chemicals span a wide range of physical–chemical properties, with log octanol–air partitioning coefficients from 2.1 to 13.7. All chemicals were quantitatively and precisely recovered from initial exposures, averaging 102% recovery with relative SD ≤ 21%. In simulated transport conditions at +30 °C, SVOCs were stable up to 1 month (average: 104%) and VOC levels were unchanged (average: 99%) for 7 days. During long-term storage at − 20 °C up to 3 (VOCs) or 6 months (SVOCs), all chemical levels were stable from chemical degradation or diffusional losses, averaging 110%. Applying a paired wristband/active sampler study with human participants, the first estimates of wristband–air partitioning coefficients for PAHs are presented to aid in environmental air concentration estimates. Extrapolation of these stability results to other chemicals within the same physical–chemical parameters is expected to yield similar results.
    [Show full text]
  • Passive Sampling of Polychlorinated Biphenyls (Pcb) in Indoor Air: Towards a Cost-Effective Screening Tool
    PASSIVE SAMPLING OF POLYCHLORINATED BIPHENYLS (PCB) IN INDOOR AIR: TOWARDS A COST-EFFECTIVE SCREENING TOOL Scientifi c Report from DCE – Danish Centre for Environment and Energy No. 128 2014 AARHUS AU UNIVERSITY DCE – DANISH CENTRE FOR ENVIRONMENT AND ENERGY [Blank page] PASSIVE SAMPLING OF POLYCHLORINATED BIPHENYLS (PCB) IN INDOOR AIR: TOWARDS A COST-EFFECTIVE SCREENING TOOL Scientifi c Report from DCE – Danish Centre for Environment and EnergyNo. 128 2014 Katrin Vorkamp1 Philipp Mayer2 1 Aarhus University, Department of Environmental Science 2 Technical University of Denmark (DTU), Department of Environmental Engineering AARHUS AU UNIVERSITY DCE – DANISH CENTRE FOR ENVIRONMENT AND ENERGY Data sheet Series title and no.: Scientific Report from DCE – Danish Centre for Environment and Energy No. 128 Title: Passive sampling of polychlorinated biphenyls (PCB) in indoor air: Towards a cost- effective screening tool Author: Katrin Vorkamp1 and Philipp Mayer2 Institutions: 1Aarhus University, Department of Environmental Science 2Technical University of Denmark (DTU), Department of Environmental Engineering Publisher: Aarhus University, DCE – Danish Centre for Environment and Energy © URL: http://dce.au.dk/en Year of publication: January 2015 Editing completed: December 2014 Quality assurance, DCE: Susanne Boutrup Financial support: Danish Energy Agency Please cite as: Vorkamp, K. & Mayer, P. 2015. Passive sampling of polychlorinated biphenyls (PCB) in indoor air: Towards a cost-effective screening tool. Aarhus University, DCE – Danish Centre for Environment and Energy, 118 pp. Scientific Report from DCE – Danish Centre for Environment and Energy No. 128. http://dce2.au.dk/pub/SR128.pdf Abstract: PCBs were widely used in construction materials in the 1906s and 1970s, a period of high building activity in Denmark.
    [Show full text]
  • Aquatic Global Passive Sampling
    University of Rhode Island DigitalCommons@URI Graduate School of Oceanography Faculty Graduate School of Oceanography Publications 2017 Aquatic Global Passive Sampling (AQUA-GAPS) Revisited – First Steps towards a Network of Networks for Organic Contaminants in the Aquatic Environment Rainer Lohmann University of Rhode Island, [email protected] Derek Muir See next page for additional authors Follow this and additional works at: https://digitalcommons.uri.edu/gsofacpubs The University of Rhode Island Faculty have made this article openly available. Please let us know how Open Access to this research benefits oy u. This is a pre-publication author manuscript of the final, published article. Terms of Use This article is made available under the terms and conditions applicable towards Open Access Policy Articles, as set forth in our Terms of Use. Citation/Publisher Attribution Lohmann, Rainer; Muir, Derek; Zeng, Eddy; Bao, Lian-Jun; Allan, Ian; Arinaitwe, Kenneth; Booij, Kees; Helm, Paul; Kaserzon, Sarit; Mueller, Jochen; Shibata, Yasuyuki; Smedes, Foppe; Tsapakis, Manolis; Wong, Charles; You, Jing. "Aquatic Global Passive Sampling (AQUA-GAPS) Revisited – First Steps towards a Network of Networks for Organic Contaminants in the Aquatic Environment". Environ Sci Technol 2017, 51, 1060-1067. DOI: 10.1021/acs.est.6b05159 Available at: http://dx.doi.org/10.1021/acs.est.6b05159 This Article is brought to you for free and open access by the Graduate School of Oceanography at DigitalCommons@URI. It has been accepted for inclusion in Graduate School of Oceanography Faculty Publications by an authorized administrator of DigitalCommons@URI. For more information, please contact [email protected]. Authors Rainer Lohmann, Derek Muir, Eddy Y.
    [Show full text]
  • Time-Integrated Passive Sampling As a Complement to Conventional
    Prepared in cooperation with the Eugene Water & Electric Board Time-Integrated Passive Sampling as a Complement to Conventional Point-in-Time Sampling for Investigating Drinking-Water Quality, McKenzie River Basin, Oregon, 2007 and 2010–11 Scientific Investigations Report 2013–5215 U.S. Department of the Interior U.S. Geological Survey Time-Integrated Passive Sampling as a Complement to Conventional Point-in-Time Sampling for Investigating Drinking-Water Quality, McKenzie River Basin, Oregon, 2007 and 2010–11 By Kathleen A. McCarthy and David A. Alvarez Prepared in cooperation with the Eugene Water & Electric Board Scientific Investigations Report 2013–5215 U.S. Department of the Interior U.S. Geological Survey U.S. Department of the Interior SALLY JEWELL, Secretary U.S. Geological Survey Suzette M. Kimball, Acting Director U.S. Geological Survey, Reston, Virginia: 2014 For more information on the USGS—the Federal source for science about the Earth, its natural and living resources, natural hazards, and the environment, visit http://www.usgs.gov or call 1–888–ASK–USGS. For an overview of USGS information products, including maps, imagery, and publications, visit http://www.usgs.gov/pubprod To order this and other USGS information products, visit http://store.usgs.gov Any use of trade, firm, or product names is for descriptive purposes only and does not imply endorsement by the U.S. Government. Although this information product, for the most part, is in the public domain, it also may contain copyrighted materials as noted in the text. Permission to reproduce copyrighted items must be secured from the copyright owner. Suggested citation: McCarthy, K.A., and Alvarez, D.A., 2014, Time-integrated passive sampling as a complement to conventional point- in-time sampling for investigating drinking-water quality, McKenzie River Basin, Oregon, 2007 and 2010–11: U.S.
    [Show full text]
  • Review of the Background and Application of Triolein-Containing Semipermeable Membrane Devices in Aquatic Environmental Study
    University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln USGS Staff -- Published Research US Geological Survey 2002 Review of the background and application of triolein-containing semipermeable membrane devices in aquatic environmental study Yibing Lu Research Center for Eco-Enironmental Sciences Zijian Wang Research Center for Eco-Enironmental Sciences, [email protected] James Huckins Columbia Enironmental Research Center, [email protected] Follow this and additional works at: https://digitalcommons.unl.edu/usgsstaffpub Lu, Yibing; Wang, Zijian; and Huckins, James, "Review of the background and application of triolein- containing semipermeable membrane devices in aquatic environmental study" (2002). USGS Staff -- Published Research. 552. https://digitalcommons.unl.edu/usgsstaffpub/552 This Article is brought to you for free and open access by the US Geological Survey at DigitalCommons@University of Nebraska - Lincoln. It has been accepted for inclusion in USGS Staff -- Published Research by an authorized administrator of DigitalCommons@University of Nebraska - Lincoln. Aquatic Toxicology 60 (2002) 139–153 www.elsevier.com/locate/aquatox Review Review of the background and application of triolein-containing semipermeable membrane devices in aquatic environmental study Yibing Lu a, Zijian Wang a,*, James Huckins b a State Key Laboratory of En6ironmental Aquatic Chemistry, Research Center for Eco-En6ironmental Sciences, Beijing 100085, China b Columbia En6ironmental Research Center, USGS, Columbia, MO, USA Received 5 March 2002; accepted 15 April 2002 Abstract This paper briefly reviews research on passive in situ samplers for aquatic environments but focuses on the development and application of the triolein-containing semipermeable membrane device in aquatic environmental monitoring. Special attention is paid to the calibration of the devices, quality control issues, and its potential uses in environmental assessments of aquatic contaminants.
    [Show full text]
  • Guidelines for Using Passive Samplers to Monitor Organic Contaminants at Superfund Sediment Sites 1
    Contents 1. Introduction ....................................................................................................... 1 2. Why use passive samplers? The advantages .................................................. 2 3. What passive samplers tell us ........................................................................... 5 4. Types of passive samplers ................................................................................ 7 5. Some theory on how passive samplers work .................................................... 9 6. Preparing, deploying, recovering, and storing passive samplers .....................11 7. Selecting passive samplers ............................................................................. 15 8. Analyzing passive sampler data ...................................................................... 15 9. Brief case study ............................................................................................... 19 10. Remaining scientific challenges in using passive samplers ............................ 20 11. US EPA contacts working with passive samplers ........................................... 22 12. Summary ......................................................................................................... 22 13. Acknowledgements ......................................................................................... 24 14. References used in this document ................................................................. 25 Appendix A ..........................................................................................................
    [Show full text]
  • Passive Sampling Methods for Contaminated Sediments: State Of
    Integrated Environmental Assessment and Management — Volume 10, Number 2—pp. 179–196 © 2014 The Authors. Integrated Environmental Assessment and Management published by Wiley Periodicals, Inc. on behalf of SETAC. 179 Passive Sampling Methods for Contaminated Sediments: State of the Science for Metals Willie JGM Peijnenburg,*yz Peter R Teasdale,§ Danny Reible,k Julie Mondon,# William W Bennett,§ and Peter GC Campbellyy yInstitute of Environmental Sciences (CML), University of Leiden, Leiden, The Netherlands zNational Institute for Public Health and the Environment, Center for Safety of Substances and Products, Bilthoven, The Netherlands §Environmental Futures Research Institute, School of Environment, Griffith University, Gold Coast Campus, Southport, Australia kDepartment of Civil and Environmental Engineering, Texas Tech University, Lubbock, Texas, USA #Center for Integrated Ecology, Environmental Sustainability Research Cluster, Deakin University, Warrnambool Campus, Warrnambool, Victoria, Australia yyUniversité du Québec, Institut National de la Recherche Scientifique, Centre Eau, Terre et Environnement, Québec, Canada (Submitted 18 July 2013; Returned for Revision 23 August 2013; Accepted 1 November 2013) Special Series EDITOR'S NOTE: This paper represents 1 of 6 papers in the special series “Passive Sampling Methods for Contaminated Sediments,” which was generated from the SETAC Technical Workshop “Guidance on Passive Sampling Methods to Improve Management of Contaminated Sediments,” held November 2012 in Costa Mesa, California, USA. Recent advances in passive sampling methods (PSMs) offer an improvement in risk‐based decision making, since bioavailability of sediment contaminants can be directly quantified. Forty‐five experts, representing PSM developers, users, and decision makers from academia, government, and industry, convened to review the state of science to gain consensus on PSM applications in assessing and supporting management actions on contaminated sediments.
    [Show full text]
  • Groundwater Quality Measurement with Passive Samplers Code of Best Practices
    Groundwater quality measurement with passive samplers Code of best practices Groundwater quality measurement with passive samplers - Code of best practices 2 Summary In Europe, passive sampling is an emerging way of measuring groundwater quality and therefore of characterizing and monitoring polluted sites. In the USA, the scientific literature is abundant on the subject and a lot of studies were conducted to assess their efficiency to measure groundwater quality. Nevertheless, in the frame of a previous project (the METROCAP project), a survey was conducted amongst French consultants and showed that passive samplers were not widely used in France because there was a need to provide feedback and guidelines to promote the use of passive samplers in a regulatory context. The situation seems quite similar in the other European countries. In this context, after a general presentation of the different groundwater sampling techniques and particularly passive sampling, this report provides some feedback on the use of 4 passive samplers in the frame of the CityChlor project: PDBs (polyethylene diffusion bags), regenerated cellulose dialysis membranes, ceramic dosimeters and Gore sorber modules. In general, passive samplers seem technically and economically interesting to measure groundwater quality at contaminated sites because they showed a lot of advantages comparing to the conventional sampling technique: they were easy to install and retrieve, no external energy source or additional equipment was needed, no purge water was produced, no filtration was required on site and no cross contamination occurred. In addition they were generally more cost-effective than the conventional sampling technique. They could be seen as complementary tools to the conventional sampling technique, giving access to information that are not or hardly available with the conventional sampling technique, such as depth discrete samples or vertical contaminant profiling when deployed in series.
    [Show full text]
  • Sampling Rate of Polar Organic Chemical Integrative Sampler (POCIS): Influence Factors and Calibration Methods
    applied sciences Review Sampling Rate of Polar Organic Chemical Integrative Sampler (POCIS): Influence Factors and Calibration Methods Liyang Wang 1,2 , Ruixia Liu 1,2,*, Xiaoling Liu 1 and Hongjie Gao 1 1 State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, China; [email protected] (L.W.); [email protected] (X.L.); [email protected] (H.G.) 2 College of Water Sciences, Beijing Normal University, Beijing 100875, China * Correspondence: [email protected]; Tel.: +86-10-8491-9726-601; Fax: +86-10-8491-7906 Received: 28 June 2020; Accepted: 7 August 2020; Published: 11 August 2020 Abstract: As a passive sampling device, the polar organic chemical integrative sampler (POCIS) has the characteristics of simple operation, safety, and reliability for assessing the occurrence and risk of persistent and emerging trace organic pollutants. The POCIS, allowing for the determination of time-weighted average (TWA) concentration of polar organic chemicals, exhibits good application prospects in aquatic environments. Before deploying the device in water, the sampling rate (Rs), which is a key parameter for characterizing pollutant enrichment, should be determined and calibrated accurately. However, the Rs values strongly depend on experimental hydrodynamic conditions. This paper provides an overview of the current situation of the POCIS for environmental monitoring of organic pollutants in an aquatic system. The principle and theory of the POCIS are outlined. In particular, the effect factors such as the ambient conditions, pollutant properties, and device features on the Rs are analyzed in detail from aspects of impact dependence and mechanisms.
    [Show full text]