Verifying RMS Deployment

Verify if all the RMS Virtual hosts have the required network connectivity.

• Verifying Network Connectivity, page 1 • Verifying Network Listeners, page 2 • Log Verification, page 3 • End-to-End Testing, page 4

Verifying Network Connectivity

Step 1 Verify if the RMS Virtual has network connectivity from the Central Node, using the following steps: a) Ping the gateway. (prop:vami.gateway.Central-Node or prop:Central_Node_Gateway). ) Ping the DNS servers. (prop:vami.DNS.Central-Node or prop:Central_Node_Dns1_Address & prop:Central_Node_Dns2_Address). c) Ping the NTP servers. (prop:Ntp1_Address, prop:Ntp2_Address, prop:Ntp3_Address & prop:Ntp4_Address). Step 2 Verify if the RMS Virtual host has network connectivity from the Serving Node, using the following steps: a) Ping the gateway. (prop:vami.gateway.Serving-Node or prop:Serving_Node_Gateway). b) Ping the DNS servers. (prop:vami.DNS.Serving-Node or prop:Serving_Node_Dns1_Address & prop:Serving_Node_Dns2_Address). c) Ping the NTP servers. (prop:Ntp1_Address, prop:Ntp2_Address, prop:Ntp3_Address & prop:Ntp4_Address). Step 3 Verify if the RMS Virtual host has network connectivity from the Upload Node, using the following steps: a) Ping the gateway. (prop:vami.gateway.Upload-Node or prop:Upload_Node_Gateway). b) Ping the DNS servers. (prop:vami.DNS.Upload-Node or prop:Upload_Node_Dns1_Address & prop:Upload_Node_Dns2_Address). c) Ping the NTP servers. (prop:Ntp1_Address, prop:Ntp2_Address, prop:Ntp3_Address & prop:Ntp4_Address). Step 4 Perform the additional network connectivity testing on each of the nodes, for the following optional services: a) Ping the Syslog servers (Optional). b) Ping the SNMP servers (Optional).

RAN Management System Installation Guide, Release 4.1 May 25, 2015 HF 1 Verifying RMS Deployment Verifying Network Listeners

c) Ping the SNMP trap servers (Optional).

Verifying Network Listeners Verify that the RMS virtual hosts have opened the required network listeners. If the Upload server process is not up, for details see Upload Server is Not Up.

RMS Node Component Network Listener

Central Node BAC RDU • -an | grep 443 • netstat -an | grep 8005 • netstat -an | grep 8083 • netstat -an | grep 49187 • netstat -an | grep 8090

Serving Node Cisco Prime Access Registrar () • netstat -an | grep 1812 • netstat -an | grep 8443 • netstat -an | grep 8005

Cisco Prime Network Registrar (PNR) • netstat -an | grep 61610 • netstat -an | grep 9005

BAC DPE • netstat -an | grep 2323 • netstat -an | grep 49186

Upload Node Upload Server • netstat -an |grep 8082 • netstat -an |grep 443

RAN Management System Installation Guide, Release 4.1 2 May 25, 2015 HF Verifying RMS Deployment Log Verification

Log Verification

Server Log Verification Post installation, the following server logs should be checked for verification of clean server start-up. • Central Virtual Machine (VM): ◦ /rms/data/CSCObac/agent/logs/snmpAgent_console.log ◦ /rms/data/CSCObac/agent/logs/tomcat_console.log ◦ /rms/data/dcc_ui/postgres/dbbase/pgstartup.log ◦ /rms/log/pmg/PMGServer.console.log ◦ /rms/data/nwreg2/regional/logs/install_cnr_log ◦ /rms/log/dcc_ui/ui-debug.log

• Serving VM: /rms/data/nwreg2/local/logs/install_cnr_log

Note Any errors in the above log files the of application deployment need to be notified to the operation support team.

Application Log Verification Application level logs can be referred to in case of facing application-level usage issues:

RMS Node Component Log Name

Central VM DCC_UI /rms/log/dcc_ui/ui-audit.log /rms/log/dcc_ui/ui-debug.log

PMG /rms/log/pmg/pmg-debug.log /rms/log/pmg/pmg-audit.log

BAC/RDU /rms/data/CSCObac/rdu/logs/audit.log /rms/data/CSCObac/rdu/logs/rdu.log

Serving VM PNR /rms/data/nwreg2/local/logs/ name_dhcp_1_log

RAN Management System Installation Guide, Release 4.1 May 25, 2015 HF 3 Verifying RMS Deployment End-to-End Testing

PAR /rms/app/CSCOar/logs/ name_radius_1_log Or /rms/app/CSCOar/logs/name_radius_1_trace

DPE /rms/data/CSCObac/dpe/logs/dpe.log

Upload Server VM /opt/CSCOuls/logs/*.log (uls.log, sb-events.log, nb-events.log)

End-to-End Testing Perform the following processes for end-to-end testing of the Small Cell device:

Step 1 Register a Small Cell Device. Step 2 Power on the Small Cell Device. Step 3 Verify NTP Signal. Step 4 Verify -069 Inform. Step 5 Verify Discovered Parameters. Step 6 Verify Class of Service selection. Step 7 Perform Firmware Upgrade. Step 8 Verify Updated Discovered Parameters. Step 9 Verify Configuration Synchronization. Step 10 Activate the Small Cell Device. Step 11 Verify IPSec Connection. Step 12 Verify Connection Request. Step 13 Verify Live Data Retrieval. Step 14 Verify HNB-GW Connection. Step 15 Verify Radio is Activated. Step 16 Verify User Equipment can Camp. Step 17 Place First Call. Step 18 Verify Remote Reboot. Step 19 Verify On-Demand Log Upload.

RAN Management System Installation Guide, Release 4.1 4 May 25, 2015 HF Verifying RMS Deployment Updating VMware Repository

Updating VMware Repository All the system updates for the VMware Studio and the VMware vCenter are stored on the Update Repository, and can be accessed either online through Cisco DMZ or Offline (delivered to the Customer through Services team or DVD). Perform the following procedures to apply updates on the RMS nodes:

Step 1 Disable the network interfaces for each virtual machine. Step 2 Create a snapshot of each virtual machine. Step 3 the Update ISO on the vCenter server. Step 4 Perform a check for new software availability. Step 5 Install updates using the vSphere Console. Step 6 Perform system tests to verify that the updated software features are operating properly. Step 7 Enable network interfaces for each virtual machine in the appliance. Step 8 Perform end-to-end testing.

RAN Management System Installation Guide, Release 4.1 May 25, 2015 HF 5 Verifying RMS Deployment Updating VMware Repository

RAN Management System Installation Guide, Release 4.1 6 May 25, 2015 HF