National Fire Protection Association Report

Total Page:16

File Type:pdf, Size:1020Kb

National Fire Protection Association Report National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... First Revision No. 2501-NFPA 101-2015 [ New Section after 8.2.2.4 ] 8.2.2.5* Wall Marking and Identification. For other than existing assemblies, where there is an accessible concealed floor, floor- ceiling, or attic space, fire barriers, smoke barriers, and smoke partitions shall be permanently identified with signs or stenciling in the concealed space and shall comply with all of the following: (1) Be located in accessible concealed floor, floor-ceiling, or attic spaces (2) Be located within 15 ft (4572 mm) of the end of each wall and at intervals not exceeding 30 ft (9144 mm) measured horizontally along the wall or partition 3 (3) Include lettering not less than 3 in. (76 mm) in height with a minimum ⁄8 in. (9.5 mm) stroke in a contrasting color (4) Identify the wall type and its fire-resistive rating, as applicable Supplemental Information File Name Description 101_A.8.2.2.5.docx Submitter Information Verification Submitter Full Name: Kristin Bigda Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Thu Jul 30 14:57:10 EDT 2015 Committee Statement Committee This proposal supports the concept covered by Public Inputs 285 and 454 for Statement: marking fire and smoke rated walls. It clarifies the following points: The requirements are placed in the general section in Chapter 8 so they are applicable for fire barriers, smoke barriers, and smoke partitions. Wall markings are only required for assemblies covered by NFPA 101 and NFPA 5000. The markings are only required for walls that have accessible concealed spaces, and the markings are to be provided in the concealed spaces. Page 1 of 47 1 of 16 10/20/2015 4:12 PM National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... Response Message: Public Input No. 285-NFPA 101-2015 [New Section after 8.3.2.3] Public Input No. 454-NFPA 101-2015 [New Section after 8.3.3.2.3] Page 2 of 47 2 of 16 10/20/2015 4:12 PM A.8.2.2.5 Acceptable wording may read as follows: 2 HOUR FIRE BARRIER, SMOKE BARRIER-PROTECT ALL OPENINGS Page 3 of 47 National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... First Revision No. 2513-NFPA 101-2015 [ New Section after 8.3.1.3 ] 8.3.1.4 Smoke Barrier Used as a Fire Barrier. A smoke barrier shall be permitted to be used as a fire barrier, provided that it meets the requirements of Section 8.3 . Submitter Information Verification Submitter Full Name: Kristin Bigda Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Wed Aug 05 15:04:35 EDT 2015 Committee Statement Committee Section 8.5 currently contains text for fire barriers used as smoke barriers. New Statement: language clarifies the application of the Code for those smoke barriers that are also designed and required to comply with the provisions for fire barriers. Consistent language is also being added to NFPA 5000. Response Message: Page 4 of 47 3 of 16 10/20/2015 4:12 PM National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... First Revision No. 6503-NFPA 101-2015 [ Detail ] Add new text: 8.3.6.7 Joints made between a fire barrier and a non-fire-resistance-rated floor or roof sheathing, slab or deck above shall be protected by an approved continuity head of wall joint system installed as tested in accordance with ASTM E2837, Standard Test Method for Determining the Fire Resistance of Continuity Head-of-Wall Joint Systems Installed Between Rated Wall Assemblies and Nonrated Horizontal Assemblies and the system shall have an F rating and T rating of not less than the required fire resistance rating of the fire barrier. Submitter Information Verification Submitter Full Name: KRISTIN BIGDA Organization: NATIONAL FIRE PROTECTION ASSOC Street Address: City: State: Zip: Submittal Date: Tue Aug 11 13:29:36 EDT 2015 Committee Statement Committee The extension of the fire barrier to the next horizontal assembly needs to be tested Statement: as the assembly itself. The ASTM standard provides the continuity to protect the system consistent with the barrier. Response Message: Public Input No. 334-NFPA 101-2015 [New Section after 8.3.6.6] Page 5 of 47 1 of 19 10/20/2015 4:18 PM National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... First Revision No. 6502-NFPA 101-2015 [ Sections 8.3.3, 8.3.4, 8.3.5, 8.3.6 ] 8.3.3 Fire Doors and Windows. Opening Protectives. 8.3.3.1 General. Every opening in a fire barrier shall be protected to limit the spread of fire and restrict the movement of smoke from one side of the fire barrier to the other . 8.3.3.1.1 Fire resistance–rated glazing tested in accordance with ASTM E119, Standard Test Methods for Fire Tests of Building Construction and Materials , or ANSI/UL 263, Standard for Fire Tests of Building Construction and Materials , shall be permitted in fire door assemblies and fire window assemblies where tested and installed in accordance with their listings. 8.3.3.1.2 New fire resistance–rated glazing shall be marked in accordance with Table 8.3.3.12 and Table 8.3.4.2. Such marking shall be permanently affixed. 8.3.3.2 Minimum Fire Protection Rating. 8.3.3.2.1* Fire protection ratings for products required to comply with 8.3.3 shall be as determined and reported by a nationally recognized testing agency in accordance with NFPA 252, NFPA 257, ANSI/UL 10B, Standard for Fire Tests of Door Assemblies, ANSI/UL 10C, Standard for Positive Pressure Fire Tests of Door Assemblies, or ANSI/UL 9, Standard for Fire Tests of Window Assemblies. Page 6 of 47 2 of 19 10/20/2015 4:18 PM National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... 8.3.3.2.2* Page 7 of 47 3 of 19 10/20/2015 4:18 PM National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... The fire protection rating for opening protectives in fire barriers, fire-rated smoke barriers, and fire-rated smoke partitions shall be in accordance with Table 8.3.3.2.2, except as otherwise permitted in 8.3.3.2.3 or 8.3.3.2.4. Table 8.3.3.2.2 Minimum Fire Ratings for Opening Protectives in Fire Resistance–Rated Assemblies and Fire-Rated Glazing Markings Door Fire-Rated Minimum Side Fire-Rated Glazin Walls Vision Glazing Fire Door Light/Transom Marking Side and Panel Marking Assemblies Assembly Rating (hr) Light/Transom Pa Partitions Maximum Door (hr) (hr) Size Vision Fire Fire Fire Fire Component (in. 2 ) Pane protection resistance protection resista Elevator 1 D-H-90 or 2 1 ⁄2 2 c NP 2 NP D-H-W- hoistways 155 in. D-H-W-90 D-H-60 or 1 1 2 c NP 1 NP D-H-W 155 in. D-H-W-60 1 1 D-20 or 1 1 ⁄2 ⁄3 2 d ⁄3 ⁄3 D-H-20 D-W-2 85 in. D-W-20 ≤100 in. 2 , Elevator 2 lobby (per 1 1 100 in. D-H-T-60 NP 1 NP D-H-W 7.2.13.4) a or D-H-W-60 >100 in. 2 , D-H-W-60 Vertical shafts (including 1 Maximum D-H-90 or stairways, 2 1 ⁄2 NP 2 NP D-H-W- size tested D-H-W-90 exits, and refuse chutes Maximum D-H-60 or 1 1 NP 1 NP D-H-W size tested D-H-W-60 Replacement panels in 1 1 Maximum D-20 or 1 1 existing ⁄2 ⁄3 ⁄3 ⁄3 D-H-20 D-W-2 size tested D-W-20 vertical shafts <=100 2 Fire barriers 3 3 100 in.2 in. , NP 3 NP D-H-W- a D-H-180 or D-H-W-180 >100 in. 2 , D-H-W-180 1 Maximum D-H-90 or 2 1 ⁄2 NP 2 NP D-H-W- size tested D-H-W-90 Page 8 of 47 4 of 19 10/20/2015 4:18 PM National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... Door Fire-Rated Minimum Side Fire-Rated Glazin Walls Vision Glazing Fire Door Light/Transom Marking Side and Panel Marking Assemblies Assembly Rating (hr) Light/Transom Pa Partitions Maximum Door (hr) (hr) Size Vision Fire Fire Fire Fire Component (in. 2 ) Pane protection resistance protection resista Maximum 3 D-H-45 or 1 ⁄4 size 3 e 3 e D-H-45 D-H-W D-H-W-45 ⁄4 ⁄4 tested e 1 1 Maximum D-20 or 1 1 ⁄2 ⁄3 ⁄3 ⁄3 D-H-20 D-W-2 size tested D-W-20 Horizontal 1 Maximum D-H-90 or 2 1 ⁄2 NP 2 NP D-H-W- exits size tested D-H-W-90 Horizontal exits served Maximum 3 D-H-45 or by bridges 2 ⁄4 size 3 e 3 e D-H-45 D-H-W D-H-W-45 ⁄4 ⁄4 between tested e buildings Exit access 1 Maximum D-20 or 3 3 1 ⁄3 ⁄4 ⁄4 D-H-45 D-H-W corridors f size tested D-W-20 1 1 Maximum D-20 or 1 1 ⁄2 ⁄3 ⁄3 ⁄3 D-H-20 D-H-W size tested D-W-20 Smoke 1 Maximum D-20 or 3 3 1 ⁄3 ⁄4 ⁄4 D-H-45 D-H-W barriers f size tested D-W-20 Smoke 1 1 Maximum D-20 or 1 1 ⁄2 ⁄3 ⁄3 ⁄3 D- H-20 D-H-W partitions f,g size tested D-W-20 Maximum D-H-60 or 1 1 NP 1 NP D-H-W size tested D-H-W-60 For SI units, 1 in.
Recommended publications
  • Guideline on Through Penetration Firestopping
    GUIDELINE ON THROUGH-PENETRATION FIRESTOPPING SECOND EDITION – AUGUST 2007 SHEET METAL AND AIR CONDITIONING CONTRACTORS’ NATIONAL ASSOCIATION, INC. 4201 Lafayette Center Drive Chantilly, VA 20151-1209 www.smacna.org GUIDELINE ON THROUGH-PENETRATION FIRESTOPPING Copyright © SMACNA 2007 All Rights Reserved by SHEET METAL AND AIR CONDITIONING CONTRACTORS’ NATIONAL ASSOCIATION, INC. 4201 Lafayette Center Drive Chantilly, VA 20151-1209 Printed in the U.S.A. FIRST EDITION – NOVEMBER 1996 SECOND EDITION – AUGUST 2007 Except as allowed in the Notice to Users and in certain licensing contracts, no part of this book may be reproduced, stored in a retrievable system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of the publisher. FOREWORD This technical guide was prepared in response to increasing concerns over the requirements for through-penetration firestopping as mandated by codes, specified by system designers, and required by code officials and/or other authorities having jurisdiction. The language in the model codes, the definitions used, and the expectations of local code authorities varies widely among the model codes and has caused confusion in the building construction industry. Contractors are often forced to bear the brunt of inadequate or confusing specifications, misunderstandings of code requirements, and lack of adequate plan review prior to construction. This guide contains descriptions, illustrations, definitions, recommendations on industry practices, designations of responsibility, references to other documents and guidance on plan and specification requirements. It is intended to be a generic educational tool for use by all parties to the construction process. Firestopping Guideline • Second Edition iii FIRE AND SMOKE CONTROL COMMITTEE Phillip E.
    [Show full text]
  • General Industry Safety and Health Standard Part 75. Flammable Liquids
    MIOSHA-STD-1152 (09/13) For further information 36 Pages Ph: 517-284-7740 www.michigan.gov/mioshastandards DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR’S OFFICE GENERAL INDUSTRY SAFETY STANDARDS Filed with the Secretary of State on January 1, 1975 (as amended April 30, 1982) (as amended September 18, 2013) These rules become effective immediately upon filing with the Secretary of State unless adopted under section 33, 44, or 45a(6) of 1969 PA 306. Rules adopted under these sections become effective 7 days after filing with the Secretary of State. (By authority conferred on the director of the department of licensing and regulatory affairs by sections 16 and 21 of 1974 PA 154, MCL 408.1016 and 408.1021, and Executive Reorganization Order Nos. 1996-2, 2003-1, 2008-4, and 2011-4, MCL 445.2001, 445.2011, 445.2025, and 445.2030) R 408.17501 of the Michigan Administrative Code is amended, and R 408.17502 is added to the Code, as follows: GENERAL INDUSTRY SAFETY AND HEALTH STANDARD PART 75. FLAMMABLE LIQUIDS Table of Contents R 408.17501. Adoption of standards by reference. ..... 1 1910.106(e) "Industrial plants" ................................... 20 R 408.17502. MIOSHA referenced standards. ............ 2 1910.106(f) "Bulk plants" ............................................ 23 1910.106(g) "Service stations" ................................... 26 1910.106 FLAMMABLE LIQUIDS. ............................. 2 1910.106(h) "Processing plants" ................................ 32 1910.106(a) "Definitions." As used in this section: ...... 2 1910.106(i) "Refineries, chemical plants, and 1910.106(b) "Tank storage" ......................................... 4 distilleries" ............................................................ 35 1910.106(c) "Piping, valves, and fittings" .................. 13 1910.106(j) Scope.
    [Show full text]
  • Firestopping Application Guide
    Firestopping Application Guide www.grabberman.com VERSION 4.0 NOTES Table of Contents Page Table of Contents Table Table of Contents .........................................................................................................................................................................................i General Certificate of Conformance ...............................................................................................................................................................iii LEEDS Information United States LEEDs .....................................................................................................................................................................v Canadian LEEDs .........................................................................................................................................................................vii Product Data Sheets GrabberGard EFC .........................................................................................................................................................................ix GrabberGard IFC ........................................................................................................................................................................ xiii GrabberGard EFS .......................................................................................................................................................................xvii Material Data Sheets GrabberGard EFC ........................................................................................................................................................................xxi
    [Show full text]
  • Passive Fire Protection Features Fall 2017 Career Development Bruce E
    Office of Education December and Data Management Passive Fire Protection Features Fall 2017 Career Development Bruce E. Johnson, Senior Regulatory Engineer, UL LLC •Use of Office of Education and Data Management (OEDM) training materials must be approved in writing by the State of Connecticut, Department of Administrative Services’ Office of Communications. Passive Fire Protection Features Based on the 2015 IBC Connecticut Career Development Training November-December 2017 Bruce E. Johnson UL Codes and Advisory Services UL and the UL logo are Trademarks of UL © 2017 November 2017 1 Objectives • At the end of this presentation, you will: •Understand the intent and purpose behind fire resistive construction •Understand the 2015 IBC Chapter 7 code requirements, testing procedures, plan review requirements and inspection practices relating to fire resistive construction 3 Objectives Cont. •Understand the code requirements, testing procedures, plan review requirements and inspection practices relating to the protection of penetrations •Understand the 2015 IBC Chapter 7 requirements for protecting penetrations (firestop systems) 4 2 Objectives Cont. •Be able to navigate UL’s Product SpecTM and Installation Code Link in order to identify listed products and assemblies which demonstrate compliance with the requirements of the 2015 International Building Code. Fire resistance-rated Building Elements Fire protection-rated Firestop Systems 5 Agenda • A brief IBC Basics Review • Fire-Resistance-Rated Construction •Definitions •International Building
    [Show full text]
  • Guide to Passive Fire Protection in Buildings
    Guide to Passive Fire Protection in Buildings Original manuscript Ed Soja Technical editor Colleen Wade Design and layout Koast Graphics Ltd ISBN 978-1-927258-75-0 (PDF) 978-1-927258-76-7 (epub) First released March 2017 Copyright BRANZ Ltd, 2017 Address BRANZ Ltd 1222 Moonshine Road, Judgeford 5381 Private Bag 50908, Porirua 5240 New Zealand Phone +64 4 237 1170 Fax +64 4 237 1171 BRANZ Shop www.branz.nz ALL RIGHTS RESERVED. The information contained herein is entitled to the full protection given by the Copyright Act 1994 to the holders of this copyright. Details may only be downloaded, stored or copied for personal use, by either an individual or corporate entity, for the purposes of the carrying out of a construction-related or other business or for private or educational use. Copying for the purposes of inclusion in trade or other literature for sale or transfer to a third party is strictly forbidden. All applications for reproduction in any form should be made to the Channel Delivery Team Leader, BRANZ Ltd, Private Bag 50908, Porirua City, New Zealand. Disclaimer: The information contained within this publication is of a general nature only. BRANZ does not accept any responsibility or liability for any direct, indirect, incidental, consequential, special, exemplary or punitive damage, or for any loss of profit, income or any intangible losses, or any claims, costs, expenses, or damage, whether in contract, tort (including negligence), equity or otherwise, arising directly or indirectly from or connected with your use of this publication, or your reliance on information contained in this publication.
    [Show full text]
  • Through Penetration Firestopping
    • About the Instructor • About the Sponsor • Ask an Expert This Online Learning Seminar is available through a professional courtesy provided by: 3M Industrial Adhesives and Tapes Division Fire Protection Products 3M Center, Building 225-3S-06 St. Paul, MN 55144-1000 Phone: 1-800-328-1687 Email: [email protected] Through Web: www.3m.com/firestop Penetration Firestopping START ©2014 3M. The material contained in this course was researched, assembled, and produced by 3M and remains its property. “LEED” and related logo is a trademark owned by the U.S. Green Building Council and is used by permission. The LEED® Rating System was authored by and is the property of the USGBC. Any portion of the Rating System appearing in this course is by permission of the USGBC. Questions or concerns about the content powered by of this course should be directed to the program instructor. This multimedia product is the copyright of AEC Daily. ©2014 · Table of Contents Slide 1 of 78 • About the Instructor • About the Sponsor • Ask an Expert Through Penetration Firestopping Presented by: 3M Industrial Adhesives and Tapes Division Fire Protection Products 3M Center, Building 225-3S-06 St. Paul, MN 55144-1000 Description: Provides an overview of the performance and attributes of firestopping technologies, materials, and products that are used to firestop through penetrations in commercial applications. Industry fire testing standards and third-party listings are also discussed. To ensure the accuracy of this program material, this course is valid only when listed on AEC Daily’s Online Learning Center. Please click here to verify the status of this course.
    [Show full text]
  • Firestopping of Service Penetrations Best Practice in Design and Installation
    FIRESTOPPING OF SERVICE PENETRATIONS BEST PRACTICE IN DESIGN AND INSTALLATION This guide is the result of a collaboration between these not-for- profit associations: FIRESTOPPING OF SERVICE PENETRATIONS BEST PRACTICE IN DESIGN AND INSTALLATION There has been supplementary support for this guide from the following organisations: FSi develops and Warringtonfire, manufactures a full range of part of the Element built-in passive fire protection Group, specialises in providing a systems to protect infrastructure and comprehensive range of independent fire assets for new and existing buildings around testing, assessment, engineering and the world. The key here is the reference to certification services to international systems and not individual products. FSi markets from a network of accredited manufactures passive fire protection, air sites across the globe including Europe, permeability, movement, water permeability the Middle East, Asia and Australia. They and acoustic isolation systems as well as exist to help customers make certain that general construction sealants. FSi also the materials, products and systems that offers support and training through its they make are safe, quality, compliant and highly experienced technical team and ultimately fit for purpose, leveraging 40 prides itself on the highest level of testing years of testing experience and global and technical expertise that has been built testing capabilities. up over many years. warringtonfire.com fsiltd.com Rockwool Limited is part of the Rockwool Group, with its UK factory based in Bridgend, South Wales offering a full range of sustainable, non-combustible stone wool insulation products for the construction industry. With over 80 years expertise, it is perfectly suited to tackle many of today’s biggest sustainability and development challenges, from fire resilience to energy consumption and noise pollution.
    [Show full text]
  • Through-Penetration Firestop Systems System No
    Through-penetration Firestop Systems System No. W-L-5267 F Rating - 2 Hr T Ratings - 0 and 1 Hr (See Item 4) A 1A 4B 4A 3 2 4B A 1B SECTION A-A FIRESTOP CONFIGURATION A 1 A 4C 4B 2 3 A 4A 1 SECTION A-A FIRESTOP CONFIGURATION B 1. Wall Assembly - The 2 hr fire-rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs - Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2-1/2 in. (64 mm) wide and spaced max 24 in. OC. B. Wallboard, Gypsum* - Two layers of nom 1/2 or 5/8 in. (13 or 16 mm) thick gypsum board as specified in the individual Wall and Partition Design. Max dia. of opening is 12 in. (305 mm). Page 1 of 3 UL System W-L-5267 continued… Configuration A 2. Through Penetrants - One metallic pipe or tubing to be installed either concentrically or eccentrically within the firestop system. Pipe or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes of tubing may be used: A. Steel Pipe - Nom. 8 in. (203 mm) dia. (or smaller) Schedule 10 (or heavier) steel pipe.
    [Show full text]
  • Fire Stop Systems
    Fire-rated sealants for floor and wall through-penetrations Fire Stop Systems While electrical, plumbing and mechanical systems are a necessity in building construction, it is often necessary to pass these systems through hourly fire-resistive floor or wall assemblies. Typically, openings are cut or drilled through the floor or wall, and then the penetrating items are installed. However, this leaves an opening, or annular space, through which fire can spread. Firestop materials are installed within the openings and around the penetrants to prevent the passage of flames and hot gases through an otherwise fire-resistive assembly. Fire Spread Prevention User’s Guide This brochure explains: – Where fire stop systems are used – The three types of fire stop systems that USG offers – How to select and specify the appropriate fire stop system Pages Understand Your System 4 Overview Applications Components Performance Testing Select Your System 11 Performance Selector Penetration Fire Tests Construction Joint Fire Tests Fire Containment Curtain Wall Systems Design Your System 39 Good Design Practices Specify Your System 40 Application Guide Specifications For More Information Technical Service 800 USG.4YOU Web Site www.usg.com 3 USG Fire Stop Systems Overview The intersection where two fire-rated assemblies meet (for example, a wall assembly and a floor/ceiling assembly) also creates a joint through which fire can spread. To prevent this, fire-rated construction joint assemblies are installed at these intersections. USG Fire Stop Systems address this problem of openings in the barrier. They consist of mortar-, caulk- and intumescent-type materials that provide reliable firestops. Mortar-type Materials These materials are applied wet over the forming materials (where applicable).
    [Show full text]
  • Through-Penetration Firestop Systems UL System No. C-AJ-1557 F Ratings - 2 and 3 Hr (See Item 3) T Rating - 0 Hr
    Through-penetration Firestop Systems UL System No. C-AJ-1557 F Ratings - 2 and 3 Hr (See Item 3) T Rating - 0 Hr 1 3B 2 3B A A 1A 3A SECTION A-A CONFIGURATION A 3B 3B 3B 1 A A 2 3A SECTION A-A CONFIGURATION B Page 1 of 5 UL System C-AJ-1557 continued… 1 3B 2 3A A A 1A 3B SECTION A-A CONFIGURATION C 3B 3B 3B 1 A A 3A 2 SECTION A-A CONFIGURATION D 1. Floor or Wall Assembly - Min. 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf (1600-2400 kg/m3)) concrete floor or min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight concrete wall. The min. thickness of the wall is dependent upon the firestop configuration as shown in Item 3. Wall may also be constructed of any UL Classified Concrete Blocks*. Floor may also be constructed of any min. 6 in. (152 mm) thick UL Classified hollow-core Precast Concrete Units*. If the firestop system is installed within a hollow-core precast concrete unit, max. dia. of opening shall be 7 in. (203 mm). Otherwise, max. dia. of opening is 15-1/4 in. (391 mm). See Concrete Blocks (CAZT) and Precast Concrete Units (CFTV) categories in the Fire Resistance Directory for names of manufacturers. 1A. Metallic Sleeve - (Optional) -Nom. 14 in. (356 mm) dia. (or smaller) Schedule 10 (or heavier) steel sleeve cast or grouted into floor or wall assembly, flush with floor or wall surfaces.
    [Show full text]
  • Penetration Firestopping
    NORTHWESTERN UNIVERSITY PROJECT NAME ____________ FOR: ___________ JOB # ________ ISSUED: 11/05/2018 SECTION 07 8413 – PENETRATION FIRESTOPPING GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Penetrations in fire-resistance-rated walls. 2. Penetrations in horizontal assemblies. 3. Penetrations in smoke barriers. 4. Joints in or between fire-resistance-rated constructions. 5. Joints at exterior curtain-wall/floor intersections. 6. Joints in smoke barriers. B. Related Requirements: 1. Section 092216 "Non-Structural Metal Framing" for firestop tracks for metal-framed partition heads. 1.3 ACTION SUBMITTALS A. Product Data: For each type of product. B. LEED Submittals: 1. Product Data for Credit IEQ 4.1: For penetration firestopping sealants and sealant primers, documentation including printed statement of VOC content. C. Product Schedule: For each penetration and joint firestopping system. Include location, illustration of firestopping system, and design designation of qualified testing and inspecting agency. 1. Provide a "use matrix" indicating manufacturer and UL label system for each condition. 2. Engineering Judgments: Where Project conditions require modification to a qualified testing and inspecting agency's illustration for a particular penetration or joint firestopping system, submit illustration, with modifications marked, approved by penetration or joint firestopping system manufacturer's fire-protection engineer as an engineering judgment or equivalent fire-resistance-rated assembly. Obtain approval of authorities having jurisdiction prior to submittal. PENETRATION FIRESTOPPING 07 8413 - 1 NORTHWESTERN UNIVERSITY PROJECT NAME ____________ FOR: ___________ JOB # ________ ISSUED: 11/05/2018 1.4 INFORMATIONAL SUBMITTALS A.
    [Show full text]
  • Understanding and Applying Code Requirements for Firestopping
    Understanding and Applying Code Requirements for Firestopping Ted Colwell 3M Tim Mattox, Sr. Specified Technologies Inc. International Firestop Council -PRESENTATION CODE OF ETHICS- The Representative, when speaking about firestopping technology and using language, information, presentations, logos, or any other communication means that could be reasonably likely to cause the recipient(s) of such information to believe that the communication represents an official IFC technical viewpoint, shall: • Hold themselves out to the public with professionalism and sound ethics by conducting themselves in a way that reflects positively on IFC and the IFC members • Clearly state their affiliation • Identify their relationship with IFC • Declare that they are presenting an official (unmodified) presentation prepared by IFC • Indicate whether the presentation is at the official request of IFC • This presentation will not highlight, focus or reference to a specific product of manufacturer 2 Seminar agenda • What is firestopping, and why is it required? • Code Requirements - overview • Penetration Firestop Systems • Membrane penetrations • Firestop installation options • Engineering judgments • Special inspection and special inspectors • Plan review and inspection process recommendations • Recognizing firestop installation problems 3 Understanding the Concept of Balanced Fire Protection Balanced Fire Protection • An integrated system of fire and smoke protection elements in the construction environment composed of detection, suppression and containment
    [Show full text]