National Fire Protection Association Report

National Fire Protection Association Report

National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... First Revision No. 2501-NFPA 101-2015 [ New Section after 8.2.2.4 ] 8.2.2.5* Wall Marking and Identification. For other than existing assemblies, where there is an accessible concealed floor, floor- ceiling, or attic space, fire barriers, smoke barriers, and smoke partitions shall be permanently identified with signs or stenciling in the concealed space and shall comply with all of the following: (1) Be located in accessible concealed floor, floor-ceiling, or attic spaces (2) Be located within 15 ft (4572 mm) of the end of each wall and at intervals not exceeding 30 ft (9144 mm) measured horizontally along the wall or partition 3 (3) Include lettering not less than 3 in. (76 mm) in height with a minimum ⁄8 in. (9.5 mm) stroke in a contrasting color (4) Identify the wall type and its fire-resistive rating, as applicable Supplemental Information File Name Description 101_A.8.2.2.5.docx Submitter Information Verification Submitter Full Name: Kristin Bigda Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Thu Jul 30 14:57:10 EDT 2015 Committee Statement Committee This proposal supports the concept covered by Public Inputs 285 and 454 for Statement: marking fire and smoke rated walls. It clarifies the following points: The requirements are placed in the general section in Chapter 8 so they are applicable for fire barriers, smoke barriers, and smoke partitions. Wall markings are only required for assemblies covered by NFPA 101 and NFPA 5000. The markings are only required for walls that have accessible concealed spaces, and the markings are to be provided in the concealed spaces. Page 1 of 47 1 of 16 10/20/2015 4:12 PM National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... Response Message: Public Input No. 285-NFPA 101-2015 [New Section after 8.3.2.3] Public Input No. 454-NFPA 101-2015 [New Section after 8.3.3.2.3] Page 2 of 47 2 of 16 10/20/2015 4:12 PM A.8.2.2.5 Acceptable wording may read as follows: 2 HOUR FIRE BARRIER, SMOKE BARRIER-PROTECT ALL OPENINGS Page 3 of 47 National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... First Revision No. 2513-NFPA 101-2015 [ New Section after 8.3.1.3 ] 8.3.1.4 Smoke Barrier Used as a Fire Barrier. A smoke barrier shall be permitted to be used as a fire barrier, provided that it meets the requirements of Section 8.3 . Submitter Information Verification Submitter Full Name: Kristin Bigda Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Wed Aug 05 15:04:35 EDT 2015 Committee Statement Committee Section 8.5 currently contains text for fire barriers used as smoke barriers. New Statement: language clarifies the application of the Code for those smoke barriers that are also designed and required to comply with the provisions for fire barriers. Consistent language is also being added to NFPA 5000. Response Message: Page 4 of 47 3 of 16 10/20/2015 4:12 PM National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... First Revision No. 6503-NFPA 101-2015 [ Detail ] Add new text: 8.3.6.7 Joints made between a fire barrier and a non-fire-resistance-rated floor or roof sheathing, slab or deck above shall be protected by an approved continuity head of wall joint system installed as tested in accordance with ASTM E2837, Standard Test Method for Determining the Fire Resistance of Continuity Head-of-Wall Joint Systems Installed Between Rated Wall Assemblies and Nonrated Horizontal Assemblies and the system shall have an F rating and T rating of not less than the required fire resistance rating of the fire barrier. Submitter Information Verification Submitter Full Name: KRISTIN BIGDA Organization: NATIONAL FIRE PROTECTION ASSOC Street Address: City: State: Zip: Submittal Date: Tue Aug 11 13:29:36 EDT 2015 Committee Statement Committee The extension of the fire barrier to the next horizontal assembly needs to be tested Statement: as the assembly itself. The ASTM standard provides the continuity to protect the system consistent with the barrier. Response Message: Public Input No. 334-NFPA 101-2015 [New Section after 8.3.6.6] Page 5 of 47 1 of 19 10/20/2015 4:18 PM National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... First Revision No. 6502-NFPA 101-2015 [ Sections 8.3.3, 8.3.4, 8.3.5, 8.3.6 ] 8.3.3 Fire Doors and Windows. Opening Protectives. 8.3.3.1 General. Every opening in a fire barrier shall be protected to limit the spread of fire and restrict the movement of smoke from one side of the fire barrier to the other . 8.3.3.1.1 Fire resistance–rated glazing tested in accordance with ASTM E119, Standard Test Methods for Fire Tests of Building Construction and Materials , or ANSI/UL 263, Standard for Fire Tests of Building Construction and Materials , shall be permitted in fire door assemblies and fire window assemblies where tested and installed in accordance with their listings. 8.3.3.1.2 New fire resistance–rated glazing shall be marked in accordance with Table 8.3.3.12 and Table 8.3.4.2. Such marking shall be permanently affixed. 8.3.3.2 Minimum Fire Protection Rating. 8.3.3.2.1* Fire protection ratings for products required to comply with 8.3.3 shall be as determined and reported by a nationally recognized testing agency in accordance with NFPA 252, NFPA 257, ANSI/UL 10B, Standard for Fire Tests of Door Assemblies, ANSI/UL 10C, Standard for Positive Pressure Fire Tests of Door Assemblies, or ANSI/UL 9, Standard for Fire Tests of Window Assemblies. Page 6 of 47 2 of 19 10/20/2015 4:18 PM National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... 8.3.3.2.2* Page 7 of 47 3 of 19 10/20/2015 4:18 PM National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... The fire protection rating for opening protectives in fire barriers, fire-rated smoke barriers, and fire-rated smoke partitions shall be in accordance with Table 8.3.3.2.2, except as otherwise permitted in 8.3.3.2.3 or 8.3.3.2.4. Table 8.3.3.2.2 Minimum Fire Ratings for Opening Protectives in Fire Resistance–Rated Assemblies and Fire-Rated Glazing Markings Door Fire-Rated Minimum Side Fire-Rated Glazin Walls Vision Glazing Fire Door Light/Transom Marking Side and Panel Marking Assemblies Assembly Rating (hr) Light/Transom Pa Partitions Maximum Door (hr) (hr) Size Vision Fire Fire Fire Fire Component (in. 2 ) Pane protection resistance protection resista Elevator 1 D-H-90 or 2 1 ⁄2 2 c NP 2 NP D-H-W- hoistways 155 in. D-H-W-90 D-H-60 or 1 1 2 c NP 1 NP D-H-W 155 in. D-H-W-60 1 1 D-20 or 1 1 ⁄2 ⁄3 2 d ⁄3 ⁄3 D-H-20 D-W-2 85 in. D-W-20 ≤100 in. 2 , Elevator 2 lobby (per 1 1 100 in. D-H-T-60 NP 1 NP D-H-W 7.2.13.4) a or D-H-W-60 >100 in. 2 , D-H-W-60 Vertical shafts (including 1 Maximum D-H-90 or stairways, 2 1 ⁄2 NP 2 NP D-H-W- size tested D-H-W-90 exits, and refuse chutes Maximum D-H-60 or 1 1 NP 1 NP D-H-W size tested D-H-W-60 Replacement panels in 1 1 Maximum D-20 or 1 1 existing ⁄2 ⁄3 ⁄3 ⁄3 D-H-20 D-W-2 size tested D-W-20 vertical shafts <=100 2 Fire barriers 3 3 100 in.2 in. , NP 3 NP D-H-W- a D-H-180 or D-H-W-180 >100 in. 2 , D-H-W-180 1 Maximum D-H-90 or 2 1 ⁄2 NP 2 NP D-H-W- size tested D-H-W-90 Page 8 of 47 4 of 19 10/20/2015 4:18 PM National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... Door Fire-Rated Minimum Side Fire-Rated Glazin Walls Vision Glazing Fire Door Light/Transom Marking Side and Panel Marking Assemblies Assembly Rating (hr) Light/Transom Pa Partitions Maximum Door (hr) (hr) Size Vision Fire Fire Fire Fire Component (in. 2 ) Pane protection resistance protection resista Maximum 3 D-H-45 or 1 ⁄4 size 3 e 3 e D-H-45 D-H-W D-H-W-45 ⁄4 ⁄4 tested e 1 1 Maximum D-20 or 1 1 ⁄2 ⁄3 ⁄3 ⁄3 D-H-20 D-W-2 size tested D-W-20 Horizontal 1 Maximum D-H-90 or 2 1 ⁄2 NP 2 NP D-H-W- exits size tested D-H-W-90 Horizontal exits served Maximum 3 D-H-45 or by bridges 2 ⁄4 size 3 e 3 e D-H-45 D-H-W D-H-W-45 ⁄4 ⁄4 between tested e buildings Exit access 1 Maximum D-20 or 3 3 1 ⁄3 ⁄4 ⁄4 D-H-45 D-H-W corridors f size tested D-W-20 1 1 Maximum D-20 or 1 1 ⁄2 ⁄3 ⁄3 ⁄3 D-H-20 D-H-W size tested D-W-20 Smoke 1 Maximum D-20 or 3 3 1 ⁄3 ⁄4 ⁄4 D-H-45 D-H-W barriers f size tested D-W-20 Smoke 1 1 Maximum D-20 or 1 1 ⁄2 ⁄3 ⁄3 ⁄3 D- H-20 D-H-W partitions f,g size tested D-W-20 Maximum D-H-60 or 1 1 NP 1 NP D-H-W size tested D-H-W-60 For SI units, 1 in.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    47 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us