A Castor Oil-Containing Dental Luting Agent: Effects RIF\FOLFORDGLQJDQGVWRUDJHWLPHRQÀH[XUDO Strength

Total Page:16

File Type:pdf, Size:1020Kb

A Castor Oil-Containing Dental Luting Agent: Effects RIF\FOLFORDGLQJDQGVWRUDJHWLPHRQÀH[XUDO Strength www.scielo.br/jaos http://dx.doi.org/10.1590/1678-775720140069 A castor oil-containing dental luting agent: effects RIF\FOLFORDGLQJDQGVWRUDJHWLPHRQÀH[XUDO strength Juliana dos Reis DERCELI1, Laiza Maria Grassi FAIS2, Lígia Antunes Pereira PINELLI2 1- Department of Restorative Dentistry, Ribeirão Preto School of Dentistry, University of São Paulo, Ribeirão Preto, SP, Brazil. 2- Department of Dental Materials and Prosthodontics, Araraquara Dental School, Univ. Estadual Paulista - UNESP, Araraquara, SP, Brazil. Corresponding address: Lígia Antunes Pereira Pinelli - Rua Humaitá, 1680 - Centro - Araraquara - SP - Brazil - 14801-903 - Phone: +55 (16) 3301-6413 - Fax: +55 (16) 3301-6406 - e-mail: [email protected] 6XEPLWWHG)HEUXDU\0RGL¿FDWLRQ-XO\$FFHSWHG$XJXVW ABSTRACT avorable results in the use of castor oil polyurethane (COP) as pulp capping, membrane Fmaterial, sealer, mouthwash and in bone repair, associated with the fact that Ricinus communis is not derived from petroleum and it is abundant in Brazil, encourage researches LQWKHGHYHORSPHQWRIOXWLQJDJHQWV2EMHFWLYHV7KLVVWXG\FRPSDUHGWKHÀH[XUDOVWUHQJWK (FS) of a castor oil-containing dental luting agent with a weight percentage of 10% (wt%) of calcium carbonate (COP10) with RelyX ARC (RX) after mechanical cycling (MC) and distilled water storage. Material and Methods: Sixty-four specimens (25x2x2 mm) were fabricated and divided into two groups, COP10 and RX (control). Each group was divided into 4 subgroups (n=8) according to the storage time, 24 hours (24 h) or 60 days (60 d), and the performance (MC+FS) or not (only FS) of the mechanical cycling test. The FS (10 kN; 0.5 mm/min) and MC tests (10,000 cycles, 5 Hz, 0.5 mm/min) were carried out using an MTS-810 machine. The data were analyzed using ANOVA (α=0.05). Results: The obtained FS (MPa) values were: COP10 24h- 19.04±2.41; COP10 60d- 17.92±3.54; RX 24h- 75.19±3.43; RX 60d- 88.77±6.89. All the RX specimens submitted to MC fractured, while the values for COP10 after MC were as follows: COP10 24h- 17.90±1.87 and COP10 60d- 18.60±1.60. Conclusions: A castor oil-containing dental luting agent with a weight percentage of 10% (wt%) of calcium carbonate is resistant to mechanical cycling without GHFUHDVHVLQÀH[XUDOVWUHQJWK+RZHYHUPHDQ&23VKRZHGRQO\DERXWRIWKH5HO\; $5&PHDQÀH[XUDOVWUHQJWK Keywords: Biocompatible materials. Polyurethanes. Dental cements. Material resistance. Aging. INTRODUCTION favorable results in tests for biocompatibility22. Castor oil is a new material that is globally available, Polymers are biocompatible materials of natural and it has received much attention in recent years or synthetic origin that can be prepared by different because of its availability on a large commercial methods34. In dentistry, various polymers are scale23. used, such as silicone, methyl methacrylate and The COP is a biocompatible, antimicrobial, polyurethane. Currently, vegetable-polyurethane, osteointegrable and absorbable, osteoconductive which combines the versatility of polymer formulation and osteoinductive13. In dentistry, the use of this while addressing the global concern towards polymer has been studied in direct pulp capping5, producing new biomaterials from sustainable as a membrane material22, as a sealer31, as a resources, has become one of the most studied mouthwash28, as bone prosthesis and in alveolar biomaterials3. The use of vegetable-polyurethane healing7 and bone reconstruction20. In clinical derived from castor oil (COP) in the health science research focusing on human dental alveoli, Jowett, fields has been studied, and COP has shown et al.19 (1988) showed that this polyurethane has J Appl Oral Sci. 496 2014;22(6):496-501 $FDVWRURLOFRQWDLQLQJGHQWDOOXWLQJDJHQWHIIHFWVRIF\FOLFORDGLQJDQGVWRUDJHWLPHRQÀH[XUDOVWUHQJWK good biocompatibility for use both in soft and hard ZLWKG\QDPLFORDGVLQRUGHUWRDVVHVVWKHLQÀXHQFH tissue, has osteoinductive properties, and can be of stress on the material16,21. bactericidal and fungicidal when combined with The aim of this study was to assess the behavior calcium carbonate. of COP under masticatory stress simulated by The versatility of the polyurethane derived from PHFKDQLFDO F\FOLQJ 7KH ÀH[XUDO VWUHQJWK RI &23 castor oil as well as the aforementioned positive with a weight percentage of 10% (wt%) of calcium aspects support the study of COP as a dental luting carbonate was analyzed with and without the agent. Although a wide range of dental luting agents performance of the mechanical cycling test as well is commercially available, the selection of a luting as with storage in distilled water. The results were agent to be used for a given restoration should not compared with the results for RelyX ARC. The null be an arbitrary choice. It must be based on a basic hypothesis was that there is no difference between knowledge of the materials available, the type of WKHÀH[XUDOVWUHQJWKRI&23DQGWKDWRI5HO\; restoration to be placed, and the requirements ARC. GH¿QHGE\WKHSDWLHQW17 based on the functional and biological needs2 of a particular clinical situation, MATERIAL AND METHODS including handling characteristics such as working time, setting time, consistency and ease of removal The procedure of the study is summarized in of excess material33. As such, no single dental Figure 1. For the COP10 group, 32 specimens were luting agent is considered ideal, and new products fabricated with the castor oil-containing dental should be studied. It is important to characterize luting agent (Castor Oil Polyurethane - COP, Poliquil the mechanical, physical and biological properties of Araraquara, Chemical Polymers Ltd, Araraquara, SP, COP. When compared with zinc phosphate cement, Brazil) with a weight percentage of 10% (wt%) of the COP, with the addition of calcium carbonate, calcium carbonate (CaCO3). For the control group, presented better diametral tensile strength values named RX, 32 specimens were fabricated with the DQG ZDV DVVRFLDWHG ZLWK EHWWHU ¿OP WKLFNQHVV6. resin cement RelyX ARC (3M ESPE, Sumaré, SP, The addition of calcium carbonate is responsible Brazil). Each group was randomly divided into 4 for conferring radiopacity to COP29. Moreover, this subgroups (n=8) according to the storage time ¿OOHUSURYLGHVWKHUHOHDVHRIFDOFLXPLRQVIDFLOLWDWLQJ in distilled water, 24 hours (24 h) or 60 days (60 ion exchange at the bone/resin matrix interface15, d), and the performance or not of the mechanical ZKLFKPD\EHEHQH¿FLDOLQVXEJLQJLYDOUHVWRUDWLRQ cycling (MC) test. margins. The COP dental luting agents are deemed The COP was provided in a sachet containing strong enough to resist masticatory stresses and polyol, prepolymer and calcium carbonate6. This provide retention similar to that of zinc phosphate polyurethane has the following highly reactive cement, a permanent cementation material29. groups in the ricinoleic acid structure: a carbonyl In the oral cavity, the chewing forces applied to group on the first carbon, a double bond (or restorative materials result in cycles of mechanical unsaturation) on the ninth carbon and a hydroxyl impulses that lead to material fatigue and, group on the twelfth carbon. This combination of a consequently, fracture. These impulses can hydroxyl group and unsaturation occurs exclusively be simulated in the laboratory by performing in the castor oil molecule14. Prepolymer was mechanical cycling, which approaches the synthesized from methylene diphenyl diisocyanate physiological conditions generated by the chewing (MDI) and was prepolymerized with the polyol while cycle24. Fixed partial dentures are more likely to be preserving 20% of free isocyanate. When these subjected to bending forces than to other types of two components were mixed, the moisture-curing stress10,25,26$VVXFKWKHÀH[XUDOSURSHUWLHVRIWKH kinetics was determined by the polymerization restorative material are more important than their reaction between the isocyanate and hydroxyl tensile, shear and compressive strengths. Moreover, groups. The stoichiometric ratio between the polyol WKH ÀH[XUDO VWUHQJWK WHVW LV FRQVLGHUHG WKH PRVW and the prepolymer was equal to 1:0.66. appropriate for simulating the clinical situation of For the COP10 specimens, the material was material fatigue4,32 because the concentration of manually mixed in the sachet for 2 minutes. It was PDVWLFDWRU\ IRUFHV FDXVHV ÀDZV DQG PLFURFUDFNV WKHQPL[HGZLWKDVSDWXODRQD7HÀRQSODWHIRUDQ in the dental luting agent prior to the fracture or DGGLWLRQDOPLQXWHVWRREWDLQWKH¿QDOFRQVLVWHQF\6. displacement of the restoration material11. The 7KHPDWHULDOZDVLQVHUWHGLQWRD7HÀRQPDWUL[ mechanical properties of resinous materials are [[PP SRVLWLRQHGEHWZHHQWZR7HÀRQSODWHV directly related to the quantity and type of inorganic This apparatus was placed in a mechanical press particles8, degree of cure and percentage of silane- under constant load and stored in saturated water WUHDWHG ¿OOHU12 ZLWK WKH ÀH[XUDO VWUHQJWK EHLQJ vapor in a container lined with wet paper at 37°C GLUHFWO\SURSRUWLRQDOWRDPRXQWRI¿OOHUSDUWLFOHV30. for one hour9. Most current in vitro studies include cycling testing For the RX group, the cement was manipulated J Appl Oral Sci. 497 2014;22(6):496-501 DERCELI JR, FAIS LMG, PINELLI LAP according to the instructions of the manufacturer, test, which was conducted in a universal testing GLVSHQVHGRQWKH7HÀRQPDWUL[ [[PP DQG machine (MTS 810, Material Test System, Eden cured with light at three points along its length on Prairie, MN) equipped with the Test Work 4 software, both sides for 40 seconds each10. The matrix was at a crosshead of 0.5 mm/min18 and with a 10 kN placed
Recommended publications
  • Clinical Study of Dental Cements. VII. a Study of Bridge Retainers Luted with Three Different Dental Cements
    Clinical Study of Dental Cements. VII. A Study of Bridge Retainers Luted with Three Different Dental Cements RALPH G. SILVEY and GEORGE E. MYERS Crown and Bridge Department, School of Dentistry, University of Michigan, Ann Arbor, Michigan 48109, USA In a clinical study of three luting cements, the restoration could be examined for 547 bridges and 162 crowns were per- looseness. The restoration was recorded as manently cemented. Patzents were recalled successful if no looseness was detected. Pa- at 6-month intervals and the restorations tients were told to report at once should were examined for looseness. A pattern of any unusual signs or symptoms arise. retainer type, cement type and retainer success was demonstrable. Results Table 1 illustrates the rate of success of J Dent Res 57(5-6):703-707, May-June 1978. all single restorations evaluated during the study and also shows the success rate of A previous report' discussed the success each type of restoration relative to the ce- rate of three luting cements used on 547 ment used. bridges and 162 crowns. Using data col- Table 2 gives the rate of success for lected in the same study, the success rate of bridge retainers. Since a bridge generally the different types of luted retainers with consists of two or more retainers for each those cements was determined and is here- in reported. restoration and the failure of one retainer results in the failure of the restoration, no recognition is given to the retainers that re- Materials and Methods main luted in place when just restoration A description of the materials and failures are recorded.
    [Show full text]
  • Quintessence Journals
    pyr Co igh Alle Rechte vorbehaltent b y Q u in t An In Vitro Study on the Adhesion of Quartz Fiber Postsesse nz to Radicular Dentin Angelo Putignanoa/Giada Poderib/Antonio Ceruttic/Alvaro Curyd/Francesca Monticellie/ Cecilia Goraccif/Marco Ferrarig Purpose: To evaluate in vitro the bond strength at the adhesive interface between a quartz fiber post, different adhe- sive systems, and different composite cements. Materials and Methods: Thirty extracted single-rooted teeth were endodontically treated and divided into three groups (n = 10). Quartz fiber posts (DT Light-Post) were cemented with the following materials: group I: Prime & Bond NT + Self Cure Activator, and Calibra as luting cement; group II: Prime & Bond NT + Self Cure Activator, and UniFil Core; group III: UniFil Bond in combination with Unifil Core. The specimens were processed for the push-out test to evaluate bond strength at the root dentin-cement-post interface. They were sectioned along the long axis of the post into 1-mm-thick slices. A total of 60 sections was obtained from group I. Group II provided 67 slices, while group III provided 69. Load- ing was performed at a crosshead speed of 0.5 mm/min until the post segment was dislodged from the root section. Results: There was no statistically significant difference between the three experimental groups. The mean bond strength obtained for group I was 9.81 ± 5.40 MPa. For group II it was 12.06 ± 6.25 MPa, and 9.80 ± 5.01 MPa for group III. Conclusion: All the materials tested were similar in terms of providing satisfactory bond strength when used for luting fiber posts.
    [Show full text]
  • A Practical Guide to the Use of Luting Cements a Peer-Reviewed Publication Written by John O
    Earn 4 CE credits This course was written for dentists, dental hygienists, and assistants. 1992 1850s Early 1900s 1972 Resin- Zinc oxide 1900s Zinc Glass modified eugenol Zinc poly- ionomers glass phosphate carboxylate ionomers Early 2000s Self- adhesive cements A Practical Guide To The Use Of Luting Cements A Peer-Reviewed Publication Written by John O. Burgess, DDS, MS and Taneet Ghuman, BDS PennWell is an ADA CERP Recognized Provider Go Green, Go Online to take your course This course has been made possible through an unrestricted educational grant. The cost of this CE course is $59.00 for 4 CE credits. Cancellation/Refund Policy: Any participant who is not 100% satisfied with this course can request a full refund by contacting PennWell in writing. Educational Objectives a clinical success. The first change increased the strength Overall goal: The purpose of this article is to provide dental of the mixed material, allowing it to be used for permanent professionals with information on the selection and applica- cementation, and the second produced an easy-to-mix tion of luting cements. paste-paste system for provisional cementation that is still Upon completion of this course, the clinician will be able in use today.2,3 While the cement had an obtunding effect to do the following: on pulp, its disadvantages, including a high film thickness, 1. List the types of luting cements and their chemical have limited its use.4 The physical properties of dental ce- composition. ments appear in Table 1. 2. List the physical properties that affect the performance of luting cements.
    [Show full text]
  • Clinical and Technical Considerations of Luting Agents for Fixed Prosthodontics
    International Journal of Dentistry Clinical and Technical Considerations of Luting Agents for Fixed Prosthodontics Guest Editors: Cornelis H. Pameijer, Per-Olof Glantz, and J. Anthony von Fraunhofer Clinical and Technical Considerations of Luting Agents for Fixed Prosthodontics International Journal of Dentistry Clinical and Technical Considerations of Luting Agents for Fixed Prosthodontics Guest Editors: Cornelis H. Pameijer, Per-Olof Glantz, and J. Anthony von Fraunhofer Copyright © 2012 Hindawi Publishing Corporation. All rights reserved. This is a special issue published in “International Journal of Dentistry.” All articles are open access articles distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Editorial Board Ali I. Abdalla, Egypt Nicholas Martin Girdler, UK Getulio Nogueira-Filho, Canada Jasim M. Albandar, USA Rosa H. Grande, Brazil A. B. M. Rabie, Hong Kong Eiichiro . Ariji, Japan Heidrun Kjellberg, Sweden Michael E. Razzoog, USA Ashraf F. Ayoub, UK Kristin Klock, Norway Stephen Richmond, UK John D. Bartlett, USA Manuel Lagravere, Canada Kamran Safavi, USA Marilia A. R. Buzalaf, Brazil Philip J. Lamey, UK L. P. Samaranayake, Hong Kong Francesco Carinci, Italy Daniel M. Laskin, USA Robin Seymour, UK Lim K. Cheung, Hong Kong Louis M. Lin, USA Andreas Stavropoulos, Denmark BrianW.Darvell,Kuwait A. D. Loguercio, Brazil Dimitris N. Tatakis, USA J. D. Eick, USA Martin Lorenzoni, Austria Shigeru Uno, Japan Annika Ekestubbe, Sweden Jukka H. Meurman, Finland Ahmad Waseem, UK Vincent Everts, The Netherlands Carlos A. Munoz-Viveros, USA Izzet Yavuz, Turkey Roland Frankenberger, Germany Toru Nikaido, Japan Contents Clinical and Technical Considerations of Luting Agents for Fixed Prosthodontics,CornelisH.Pameijer, Per-Olof Glantz, and J.
    [Show full text]
  • Contemporary Permanent Luting Agents Used in Dentistry: a Literature Review
    Review Article Int Dent Res 2011;1:26-31 Contemporary Permanent Luting Agents Used in Dentistry: A Literature Review Ebru SÜMER1, Yalçın DEĞER2 1 Assistant, Dicle University, Faculty of Dentistry, Department of Prosthodontics, Diyarbakır, TURKEY 2 Assist. Prof., Dicle University, Faculty of Dentistry, Department of Prosthodontics, Diyarbakır, TURKEY Abstract Key Words Dental cements, luting agents, Dental cements are widely used in dentistry. Base material, temporary filling material and luting agents can all have different adhesive resin cement, resin clinical applications. Different types of cement have also been modified glass ionomer developed for various orthodontic and endodontic treatments. cement. In literature it is still argued that there is not ideal cement answering all purposes yet, so different materials are required for the comprehensive patient treatments and it is not always that easy to Correspondence: make the best choice. Ebru SÜMER The aim of this article is to provide a clinically relevant Dicle University, Dental Faculty, discussion of contemporary permanent luting agents, in order to Department of Prosthodontics, enhance the dentist’s ability to make proper cementation choices and 21280 Diyarbakir, Turkey e-mail: application. [email protected] (Int Dent Res 2011;1:26-31) Introduction Zinc phosphate, zinc oxide eugenol and silicophosphate cements were used from the early Dental cements are widely used in dentistry. twentieth century till 1970s when new cements were They can all have different clinical uses in dentistry. developed. At first polycarboxylate cement, next Cements can be used as base material, temporary glass ionomer cements and within the last thirty filling material and luting. There are also different years resin cements and resin modified glass types of cements developed to be used in ionomer cements were developed (5).
    [Show full text]
  • Review Article a Review of Luting Agents
    Hindawi Publishing Corporation International Journal of Dentistry Volume 2012, Article ID 752861, 7 pages doi:10.1155/2012/752861 Review Article A Review of Luting Agents Cornelis H. Pameijer Department of Reconstructive Sciences, School of Dental Medicine, University of Connecticut, Farmington, CT 06030, USA Correspondence should be addressed to Cornelis H. Pameijer, [email protected] Received 4 November 2011; Accepted 23 November 2011 Academic Editor: J. Anthony Von Fraunhofer Copyright © 2012 Cornelis H. Pameijer. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Due to the availability of a large number of luting agents (dental cements) proper selection can be a daunting task and is usually based on a practitioner’s reliance on experience and preference and less on in depth knowledge of materials that are used for the restoration and luting agent properties. This review aims at presenting an overview of current cements and discusses physical properties, biocompatibility and other properties that make a particular cement the preferred choice depending on the clinical indication. Tables are provided that outline the different properties of the generic classification of cements. It should be noted that no recommendations are made to use a particular commercial cement for a hypothetical clinical situation. The choice is solely the responsibility of the practitioner. The appendix is intended as a guide for the practitioner towards a recommended choice under commonly encountered clinical scenarios. Again, no commercial brands are recommended although the author recognizes that some have better properties than others.
    [Show full text]
  • Evaluation of the Water Sorption and Solubility Behavior of Different Polymeric Luting Materials
    polymers Article Evaluation of the Water Sorption and Solubility Behavior of Different Polymeric Luting Materials Nawaf Labban 1,*, Rasha AlSheikh 2 , Melvin Lund 3, Bruce A. Matis 3, B. Keith Moore 3, Michael A. Cochran 3 and Jeffrey A. Platt 4 1 Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia 2 Department of Restorative Dental Science, College of Dentistry, Imam Abdulrahan Bin Faisal University, Dammam 34212, Saudi Arabia; [email protected] 3 Department of Restorative Dentistry, Indiana University School of Dentistry, Indianapolis, IN 46202, USA; [email protected] (M.L.); [email protected] (B.A.M.); [email protected] (B.K.M.); [email protected] (M.A.C.) 4 Department of Biomedical Sciences and Comprehensive Care, Division of Dental Materials, Indiana University School of Dentistry, Indianapolis, IN 46202, USA; [email protected] * Correspondence: [email protected]; Tel.: +966-11-467-9015; Fax: +966-11-467-8548 Abstract: Objective: The study evaluated the water sorption (WSP) and water solubility (WSL) characteristics of different luting agents over a 180-day water storage period. Materials and Methods: Nine luting materials, i.e., conventional resin cement: Panavia F (PF), Rely X ARC (RA), self-adhesive resin cement: Rely X Unicem (RU), Breez (BZ), Maxcem Elite (MX), BisCem (BC) and resin-modified glass ionomer cement: FujiCem (FC), FujiPlus (FP) Rely X luting plus (RL) were assessed and Citation: Labban, N.; AlSheikh, R.; fifty-two-disc specimens of each material were fabricated. All specimens were desiccated until a Lund, M.; Matis, B.A.; Moore, B.K.; constant weight (W0) was reached.
    [Show full text]
  • Influence of Cement on Survival of All-Ceramic Restorations
    INFLUENCE OF CEMENT ON SURVIVAL OF ALL-CERAMIC RESTORATIONS THESIS Presented in Partial Fulfillment of the Requirements for The Degree of Master of Science in the Graduate School of The Ohio State University By Enas Elbahie Alakhras, B.D.S Graduate Program in Dentistry The Ohio State University 2011 Thesis Committee: Dr. Robert Seghi, DDS, MS (Advisor) Dr. William A. Brantley, PhD Dr. Noriko Katsube, PhD Copyright by Enas Mohamed Elbahie Alakhras 2011 ABSTRACT Previous research has shown that new technology in adhesive dentistry improves the performance of all-ceramic restorations. However, the major reason for failure of these restorations remains the occurrence of fractures. The overall objective of this research project was to investigate the influence of cement on the survival of all-ceramic restorations. A preliminary study was performed to evaluate the influence of the cement as a supporting structure on the survival of a simulated all-ceramic restoration. A trilayer simulation of a model restoration subjected to a clinically relevant condition of functional mastication was used. The results from the preliminary study showed that adhesively bonded specimens had higher survival rates than those conventionally cemented and that one of the adhesive cements had a significant higher survival rate than the other. Based on results from the preliminary study, three other studies were performed to investigate why adhesive cementation improves the performance of all-ceramic restorations. Results from these studies showed: (1) Resin cements had fewer defects or were void-free at the ceramic-cement interface of our ceramic model, while conventional cements showed areas of voids at the this interface.
    [Show full text]
  • Research Article Antibacterial Properties of Dental Luting Agents: Potential to Hinder the Development of Secondary Caries
    Hindawi Publishing Corporation International Journal of Dentistry Volume 2012, Article ID 529495, 7 pages doi:10.1155/2012/529495 Research Article Antibacterial Properties of Dental Luting Agents: Potential to Hinder the Development of Secondary Caries Erik Unosson,1 Yanling Cai, 2 Xiyuan Jiang,1 Jesper Lo¨of,¨ 3 Ken Welch,2 and Hakan˚ Engqvist1 1 Division of Applied Materials Science, Department of Engineering Sciences, The Angstr˚ om¨ Laboratory, Uppsala University, Box 534, 751 21 Uppsala, Sweden 2 Division of Nanotechnology and Functional Materials, Department of Engineering Sciences, The Angstr˚ om¨ Laboratory, Uppsala University, Box 534, 751 21 Uppsala, Sweden 3 Doxa AB, Axel Johanssons Gata 4-6, 754 51 Uppsala, Sweden Correspondence should be addressed to Erik Unosson, [email protected] Received 30 November 2011; Accepted 5 January 2012 Academic Editor: Cornelis H. Pameijer Copyright © 2012 Erik Unosson et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. A modified direct contact test was used to evaluate the antibacterialpropertiesoffourcommerciallyavailabledentallutingagents (RelyX Unicem, Ketac Cem, Ceramir Crown & Bridge and Harvard Cement) and two reference materials (glass-ionomer cement and calcium aluminate cement) compared to a negative-control material (PMMA). Streptococcus mutans bacteria were placed in direct contact with specimens that had been aged for 10min, 1day, and 7days, in order to test the antibacterial properties of the materials. A metabolic assay containing resazurin was used to quantify the amount of viable bacteria remaining after the direct contact tests.
    [Show full text]
  • Residue Ratio and Bond Strength of Luting Cements for Abutment Materials
    Dental Materials Journal 2009; 28(3): 261–266 Original Paper Development of a new temporary luting agent consisting of PEMA and eugenol —Residue ratio and bond strength of luting cements for abutment materials Hidetoshi OKADA, Yoshinori ISHIDA, Hiroshi NOGUCHI, Ichiro RYUKATA and Katsuya NAGAYAMA Department of Biomaterials Science, Ohu University School of Dentistry, 31-1 Misumido, Tomita-machi, Koriyama, Fukishima-ken 963-8601, Japan Corresponding author, Hidetoshi OKADA; E-mail: [email protected] PEMA- and eugenol-based trial agents (PE 1.0, PE 1.6) possessed the requisite dental engineering properties that satisfied the requirements for temporary luting agents. To assess their clinical applicability, this study examined the following properties after the trial agents were removed: their residue ratios on the abutment surface and the bond strengths of resin- modified glass ionomer cement and resin cement for the abutment materials. The residue ratio of PE 1.0 on the abutment material after temporary restoration removal was lower than those of comparable temporary luting agents (polycarboxylate cement type, zinc oxide-eugenol cement type), and no residue was recognized for PE 1.6. On bond strength, those of the resin- modified glass ionomer cement and resin cement for the resin core and bovine dentin surface after the removal of trial agents tended to be the same or increase in comparison to commercial temporary luting agents. In conclusion, results of this study suggested that the trial agents were suitable for clinical use. Keywords: Temporary luting agents, Luting cements, Bond strength Received Jun 21, 2007: Accepted Oct 1, 2008 that the trial agent could ensure easy removability of INTRODUCTION temporary restorations when needed.
    [Show full text]
  • Morphological Analysis of Glass, Carbon and Glass/Carbon Fiber Posts and Bonding to Self Or Dual-Cured Resin Luting Agents
    View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by Cadernos Espinosanos (E-Journal) J Appl Oral Sci. 2009;17(5):476-80 www.fob.usp.br/jaos or www.scielo.br/jaos MORPHOLOGICAL ANALYSIS OF GLASS, CARBON AND GLASS/CARBON FIBER POSTS AND BONDING TO SELF OR DUAL-CURED RESIN LUTING AGENTS Aloísio Oro SPAZZIN1, Rafael Ratto de MORAES2, Doglas CECCHIN3, Ana Paula FARINA4, Bruno CARLINI-JÚNIOR5, Lourenço CORRER-SOBRINHO6 1- DDS, Graduate Student, Department of Prosthodontics and Periodontics, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil. 2- DDS, MS, Graduate Student, Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil. 3- DDS, Department of Restorative Dentistry, Discipline of Endodontics, Ribeirão Preto Dental School, University of São Paulo, Ribeirão Preto, SP, Brazil. 4- DDS, Department of Prosthodontics and Dental Materials, Discipline of Oral Rehabilitation, Ribeirão Preto Dental School, University of São Paulo, Ribeirão Preto, SP, Brazil. 5- DDS, MS, PhD, Professor, Department of Restorative Dentistry, Dental School, University of Passo Fundo, Campus I, Passo Fundo, RS, Brazil. 6- DDS, MS, PhD, Professor, Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil. Corresponding address: Aloísio Oro Spazzin - Faculdade de Odontologia de Piracicaba - UNICAMP - Av. Limeira, 901 - 13414-903 - Piracicaba, SP - Brazil - Phone: 55 19 2106-5297 - Fax: 55 19 2106-5211 - e-mail: [email protected] Received: June 16, 2008 - Modification: July 7, 2008 - Accepted: November 09, 2008 ABSTRACT O bjective: The aim of this study was to evaluate the morphology of glass (GF), carbon (CF) and glass/carbon (G/CF) fiber posts and their bond strength to self or dual-cured resin luting agents.
    [Show full text]
  • Clinical Study of Dental Cements. VI. a Study of Zinc Phosphate, EBA-Reinforced Zinc Oxide Eugenol and Polyacrylic Acid Cements As Luting Agents in Fixed Prostheses
    Clinical Study of Dental Cements. VI. A Study of Zinc Phosphate, EBA-Reinforced Zinc Oxide Eugenol and Polyacrylic Acid Cements as Luting Agents in Fixed Prostheses RALPH G. SILVEY and GEORGE E. MYERS Crown and Bridge Department, School of Dentistry, University of Michigan, Ann Arbor, Michigan 48109, USA Three cements were used to cement single res- second, willingness to participate in the study. torations and bridges. Patients were recalled Patient selection on these criteria gave a sam- and evaluated for satisfactory retention of the ple of the greatest variety of restorative prob- restorations. Results obtained for a zinc phos- lems and as close as possible to those met in the phate cement, a reinforced zinc oxide eugenol general practice of dentistry. cement and a polyacrylic acid cement are pre- To achieve an approximately equal dis- sented. tribution of each of the cements, they were as- signed on a rotation basis as the cases were com- J Dent Res 56(10) :1215-1218 October 1977. pleted and ready for cementation. Occasion- A previous report' gave data on the clinical use ally the rotation sequence was changed to select as a luting agent of a zinc prosphate and a a cement more suitable for a particular case. methyl methacrylate reinforced zinc oxide This alteration was always in response to den- eugenol cement. This study compares, during tin pulp considerations and was never based on a three-year period, a zinc phosphate cement,* retentive factors or operator preference. A rou- a zinc oxide and eugenol cement reinforced tine cementation procedure was used for the with ethoxybenzoic acid and aluminat and a cementation of all cases as follows: polyacrylic acid cement: as luting agents for 1.
    [Show full text]