British Engine Boiler Insurance Company Limited
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Stoker Stove
www.mulberrystoves.com MODEL AIR INTAKE REFERENCE BOILER Standard HPBXXX • Provides heat for up to 10 radiators with 3.5kW of radiant heat and convection heat to the room. • Thermostatically controlled settings and safety over-ride in the event of a power cut stopping the pump to the heating system. • Ample firebox to suit woodburning or any solid fuel. BOILER OSA Outside Air HPBOSA • As the standard boiler, but fitted with a spigot to connect to a 4”/100mm diameter pipe that brings air from outside the house. This air is used for combustion in the stove and this arrangement is ideal for ‘air-tight’ or ‘passive’ homes. 485 440 ø150 [ø5.91] 390 329 117 607 239 571 531 ø100* 190 197 105* *With OSA adaptor only 125* FIRE-FRONT FOR BACK BOILER Standard FFBBXX • A firefront with a baffle arrangement that increases the efficiency of your back-boiler STOKER... by up to 40%. • Turns wasted heat up the chimney into warmth for the room. • Saves money even when fire is not lit by preventing warm air leaving the house up the chimney. • Easily installed - D.I.Y. fitting in 15 minutes. FIRE-FRONT BASIC Standard FFDXXX • A front and door sealing the fireplace opening allowing the user to control the burn rate by controlling the amount of air available for combustion. • Saves money even when fire is not lit by preventing warm air leaving the house up the chimney. • Easily installed - D.I.Y. fitting in 15 minutes. 485 140 ...PERFECT FOR YOUR HOME! *On Fire-Front for Back Boiler only 485 *Top Baffle fits 95% of Multi-fuel insert stoves and firefronts providing Back Boilers. -
February 2017 Monthly Report
Bank of America Credit Card Statement for the Period ending February 28, 2017 TRANSACTION REPORTS TO INTERMEDIATE MERCHANT NAME AMOUNT POSTING DATE COST ALLOCATION - EXPENSE OBJECT EXPENSE DESCRIPTION 311 CENTER SNAPENGAGE CHAT $ 49.00 02/15/2017 64505 TELECOMMUNICATIONS CARRIER LINE CH 311 MONTHLY LIVE CHAT FEE 311 CENTER WPY ONEREACH $ 198.00 02/17/2017 64505 TELECOMMUNICATIONS CARRIER LINE CH 311 MONTHLY LIVE TEXT FEE 311 CENTER AMAZON MKTPLACE PMTS $ 69.30 02/27/2017 64505 TELECOMMUNICATIONS CARRIER LINE CH 311 ANNIVERSARY GIFTS 311 CENTER AMAZON MKTPLACE PMTS $ 99.90 02/27/2017 64505 TELECOMMUNICATIONS CARRIER LINE CH 311 ANNIVERSARY GIFTS 311 CENTER BENNISONS BAKERY INC $ 64.86 02/27/2017 64505 TELECOMMUNICATIONS CARRIER LINE CH 311 OPEN HOUSE 311 CENTER VALLI PRODUCE $ 10.98 02/28/2017 64505 TELECOMMUNICATIONS CARRIER LINE CH 311 ANNIVERSARY PARTY DRINKS 311 CENTER DOLLARTREE $ 7.00 02/28/2017 64505 TELECOMMUNICATIONS CARRIER LINE CH 311 ANNIVERSARY PARTY ITEMS ADMIN SVCS/ FACILITIES ABLE DISTRIBUTORS $ 10.69 02/01/2017 65050 BUILDING MAINTENANCE MATERIAL COVER FOR THERMOSTAT ADMIN SVCS/ FACILITIES THE HOME DEPOT #1902 $ 153.64 02/01/2017 65050 BUILDING MAINTENANCE MATERIAL HEATER PARTS ADMIN SVCS/ FACILITIES CONNEXION $ 100.97 02/01/2017 65050 BUILDING MAINTENANCE MATERIAL OUTDOOR LIGHTS ADMIN SVCS/ FACILITIES THE HOME DEPOT #1902 $ 5.98 02/01/2017 65085 MINOR EQUIP & TOOLS TOOLS ADMIN SVCS/ FACILITIES SHERWIN WILLIAMS 70370 $ 210.56 02/02/2017 65050 BUILDING MAINTENANCE MATERIAL BATHROOM REMODEL PAINT ADMIN SVCS/ FACILITIES RIXON -
The Economic Development of Sheffield and the Growth of the Town Cl740-Cl820
The Economic Development of Sheffield and the Growth of the Town cl740-cl820 Neville Flavell PhD The Division of Adult Continuing Education University of Sheffield February 1996 Volume Two PART TWO THE GROWTH OF THE TOWN <2 6 ?- ti.«» *• 3 ^ 268 CHAPTER 14 EXPANSION FROM 1736 IGOSLING) TO 1771 (FAIRBANKS THE TOWN IN 1736 Sheffield in Gosling's 1736 plan was small and relatively compact. Apart from a few dozen houses across the River Dun at Bridgehouses and in the Wicker, and a similar number at Parkhill, the whole of the built-up area was within a 600 yard radius centred on the Old Church.1 Within that brief radius the most northerly development was that at Bower Lane (Gibraltar), and only a limited incursion had been made hitherto into Colson Crofts (the fields between West Bar and the river). On the western and north-western edges there had been development along Hollis Croft and White Croft, and to a lesser degree along Pea Croft and Lambert Knoll (Scotland). To the south-west the building on the western side of Coalpit Lane was over the boundary in Ecclesall, but still a recognisable part of the town.2 To the south the gardens and any buildings were largely confined by the Park wall which kept Alsop Fields free of dwellings except for the ingress along the northern part of Pond Lane. The Rivers Dun and Sheaf formed a natural barrier on the east and north-east, and the low-lying Ponds area to the south-east was not ideal for house construction. -
Royal Commission on the Private Manufacture of and Tradin in Arms
ROYAL COMMISSION ON THE PRIVATE MANUFACTURE OF AND TRADIN IN ARMS. VERBATEN SUMMARY of the EVEDENS presented by THE UNION OF DEMOCRATIC CONTROL July 17 and 18, 1935 WITNESSES: The Rt. Hon. Sir William Jowitt, P.C., K.C. Mr. R. McKinnon Wood, O.B.E., M.A., F.R.Ae.s½ Mr. J.D. Bernal, M.A. Lord Marley, D.S.C., J.P., D.L. ------------------------------- Published by: Price: 6d. nett. The Union of Democratic Control, 8d. Post free 34, Victoria Street, London, S.W. 1. 1 I N T R O D U C T I O N The Royal Commission on the Private Manufacture of and Trading in Arms was set up on February 18th 1935 with the following Terms of Reference: 1. To consider and report upon the practicability and desirability ( both from the national and international point of view ) of the adoption (a) by the United Kingdom along, (b) by the United Kingdom in conjunction with the other countries of the world, of a prohibition of private manufacture of and trade in arms and munitions of war, and the institutions of a State monopoly of such manufacture and trade. 2. To consider and report whether there are any stops which can usefully be taken to remove or minimize the kinds of objections to which private manufacture is stated in Article 8 / 5/ of the Covenant of the League of Nations to be open. 3. To examine the present arrangements in force in the United Kingdom relative to the control of the export trade in arms and munitions of war, and to report whether these arrangements require revision, and, if so, in what direction. -
SFA Guide to Open Fire Installation
SFA Guide to Open Fire Installation Solid Fuel Association 95 High Street Clay Cross Chesterfield Derbyshire S45 9 DZ www.solidfuel.co.uk Open Fires Introduction If the open fire is the main heat source in a room then to comply with Approved Document J 1A and 1B the minimum efficiency of the finished installation must be at least 37%. To achieve this, the installation will need to meet BS 8303and have a sealed in, controlled, open fire. The installation of a simple inset open fireback is not an easy task and must be undertaken correctly and with care. If this is done it will provide the end user with many years of trouble free use. The main components commonly employed in a typical installation are as follows:- 1. Fireback or boiler set 2. Throat forming lintel 3. Fire surround and superimposed hearth 4. Appliance Note: the appliance should be constructed in accordance with BS 4834 and with components (items 1 to 4 above) manufactured to the requirements of BS 1251 (Specification for open fireplace components). When manufactured to these requirements, a minimum efficiency of 37% is deemed to have been met. Where an inset open fire includes a boiler, the efficiency must be confirmed using the test given in BS 4834. All of the above components are installed or fixed to an appliance recess supported by a constructional hearth both of which are fully described later in this chapter and additional information in BS 8303. The installation methods described later deal with fireback or boiler set into a recess where a new surround is to be fitted or where the existing tiled surround is to be used. -
Thermaltricity Air Source Heat Pumps Models KS015R & KS02R
Thermaltricity® Air Source Heat Pumps Models KS015R & KS02R Introduction A Thermaltricity Air Source Heat Pump uses the same mechanical technology as a refrigerator and air conditioner but for the generation of hot water. The real selling point is the fact that it uses 1 unit of electricity to generate approximately 3 units of heat. In comparison, a standard immersion heater uses 3 units of electricity to provide 3 units of heat. The introduction of Air Source Heat Pumps to the domestic household and small business user has become financially possible because of technical advances in planet friendly refrigerants and new compressor technology. With low running costs, they are a cost effective option in new house builds, energy efficient refurbishments or retrofits and will help to mitigate the effects of increasing gas and oil prices. Features Effective efficiency = 250% to 400% Simple installation Designed to heat water continuously For a 4 person household the annual electricity use is up to 75% less than heating a conventional hot water tank Work well in humid climates Use CFC-free Refrigerant R417a Thermaltricity Air Source Heat Pumps | page 1 of 4 | v.13 290906 21 Haviland Road, Ferndown Industrial Estate, Wimborne, Dorset, BH21 7RZ Tel: +44 (0)1202 890234 Fax: +44 (0)1202 876252 Heat pumps in various forms have been around for many years and are used worldwide for both domestic and commercial applications Life expectancy of 15 years Can be integrated with a solar thermal collector through a Powertech Thermal Store for greater -
Biomass Boilers & Stoves
CI/SfB (56) First Issue December 2017 Biomass Boilers file:///Users/pjaspare/ & Stoves Downloads/LDS7_FINAL.pdf Renewable Heating Solutions from a Natural & Sustainable Fuel Source SUPERIOR HEATING SOLUTIONS SINCE 1980 2 Firebird Biomass Boilers & Stoves Renewable energy from a natural & sustainable fuel source. Contents Benefits of Biomass as a Heating Option 4 What is a Biomass Heating System? 6 Tavistock Wood Pellet Biomass Boilers 8 Dartmoor Wood Pellet Biomass Stove 14 Exmoor Wood Pellet Biomass Stove 16 Firebird Wood Burning Dry Stove 21 Firebird Support 22 3 Firebird Products Ltd are market-leading manufacturers of heating products with a proven track record built on the global supply of heating systems. Established in Ireland in 1980, the Firebird name has become synonymous with performance, quality and innovative design. At the forefront of technology, Firebird are committed to providing cost-effective, energy-efficient heating solutions that not only meet, but easily exceed today’s stringent legislative requirements. Historically an oil-fired boiler manufacturer; the addition of renewable heating options, which include air source heat pumps, biomass boilers, stoves and solar thermal systems enable Firebird to offer a total heating solutions package. 4 Firebird Biomass Boilers & Stoves Benefits of Biomass as a Heating Option Firebird’s biomass heating solutions provide an economical and environmentally-friendly alternative to traditional heating and hot water systems. 7 5 3 4 8 2 1 6 1 Firebird Tavistock 5 Sanitary system Wood Pellet Boiler 6 Accumulator 2 Pellet hopper (optional) 7 Solar thermal panel 3 Radiators 8 Solar station 4 Underfloor heating 5 Self-contained and fully automated to provide consistent heat Long-term, sustainable, renewable energy source Cost-effective heating option – unaffected by fluctuating fossil fuel prices Eligible for domestic Renewable Heat Incentive payments (RHI)* MCS & HETAS Approved** * Applicable to biomass boilers or stoves with a back boiler. -
TB) 101 Replaces the Version Originally Published 1 April 2009 Which Is Now Withdrawn
Technical Bulletin 101 Developed with HSE Title: HSE Safety Alert Risks from redundant solid fuel back boilers Date issued: 1 September 2010 Note: This version of Technical Bulletin (TB) 101 replaces the version originally published 1 April 2009 which is now withdrawn. This version has been reviewed and where appropriate revised to ensure that it remains both current and relevant. This Technical Bulletin alerts Gas Safe Registered businesses/engineers to the HSE Safety Alert related to risks from redundant solid fuel back boilers Introduction The Health and Safety Executive (HSE) in Great Britain (GB) has issued a Safety Alert aimed at homeowners, tenants, landlords and heating professionals following five incidents in GB since 2008, where redundant solid fuel back boilers have exploded. The HSE have stated that “a number of these incidents led to injury and sadly, in one case, a fatality”. The risk can arise when a disused solid fuel boiler which has not been safely decommissioned has been left at the back of a fireplace and a coal or wood fire is lit in front of it. This can mean that the boiler heats up causing the boiler casing to explode. Therefore, if you have (or know of) a redundant solid fuel back boiler you should not light an open fire in front of it. The HSE believes information published in its 2008 Safety Alert should help identify whether individuals have this potential risk in their properties/housing stock and what steps they should take. The HSE is urging those who are unsure of whether they have a redundant solid fuel back boiler behind their fireplace to seek further advice from their landlord or a competent professional such as a Gas Safe registered business. -
Grant Back Boiler Instruction
Project1:Layout 1 15/01/2013 09:23 Page 1 Installation and Operating Instructions for the GRANT TRIPLE PASS EASY CLEAN - HIGH OUTPUT BACK BOILER This Leaflet should be left with the Householder 2 1 3 GUARANTEE The Grant Triple Pass boiler is guaranteed for five years from date of purchase. This does not affect your statutory rights. This guarantee does not include cast iron parts, labour, handling or shipping. 11 9 13 4 12 8 14 8 7 6 10 5 1 Boiler 16" or 18" 2 Damper 16" or 18" 6 3 Removable Cleaning Door 16" or 18" 4 Drop Plate 16" or 18" 5 Ashpit Door 16" or 18" 6 2 Adjusting Brackets (left and right) 7 Main Frame 16" or 18" 8 Side Cheeks (left and right) IT IS RECOMMENDED THAT THIS LEAFLET BE 9 Grate 16" or 18" 10 Gas Ignitor 16" or 18" STUDIED BEFORE OPERATION OF BOILER 11 Cleaning & Operating Tool 12 Front Firebars 16" or 18" DOC: 50 REV:01 OCT2002 13 Ashpan 16" or 18" 14 Queenstar Operating Tool A Log Bar and Deepening Plate is GRANT ENGINEERING LTD. also available Crinkle, Birr, Co. Offaly, Ireland. When ordering parts state colour of enamelled Telephone: parts, no, and size i.e. 16" or 18" 057 9120089, 9120352, 9120793 Project1:Layout 1 15/01/2013 09:23 Page 2 EFFICIENT OPERATION OF APPLIANCE PROCEDURE ON LIGHTING FIRE: A deepening bar should be fitted when burning smokeless fuels and Close boiler damper, open ashpit door fully. Place firelighters on grate removed when burning coal. -
South Yorkshire
INDUSTRIAL HISTORY of SOUTH RKSHI E Association for Industrial Archaeology CONTENTS 1 INTRODUCTION 6 STEEL 26 10 TEXTILE 2 FARMING, FOOD AND The cementation process 26 Wool 53 DRINK, WOODLANDS Crucible steel 27 Cotton 54 Land drainage 4 Wire 29 Linen weaving 54 Farm Engine houses 4 The 19thC steel revolution 31 Artificial fibres 55 Corn milling 5 Alloy steels 32 Clothing 55 Water Corn Mills 5 Forging and rolling 33 11 OTHER MANUFACTUR- Windmills 6 Magnets 34 ING INDUSTRIES Steam corn mills 6 Don Valley & Sheffield maps 35 Chemicals 56 Other foods 6 South Yorkshire map 36-7 Upholstery 57 Maltings 7 7 ENGINEERING AND Tanning 57 Breweries 7 VEHICLES 38 Paper 57 Snuff 8 Engineering 38 Printing 58 Woodlands and timber 8 Ships and boats 40 12 GAS, ELECTRICITY, 3 COAL 9 Railway vehicles 40 SEWERAGE Coal settlements 14 Road vehicles 41 Gas 59 4 OTHER MINERALS AND 8 CUTLERY AND Electricity 59 MINERAL PRODUCTS 15 SILVERWARE 42 Water 60 Lime 15 Cutlery 42 Sewerage 61 Ruddle 16 Hand forges 42 13 TRANSPORT Bricks 16 Water power 43 Roads 62 Fireclay 16 Workshops 44 Canals 64 Pottery 17 Silverware 45 Tramroads 65 Glass 17 Other products 48 Railways 66 5 IRON 19 Handles and scales 48 Town Trams 68 Iron mining 19 9 EDGE TOOLS Other road transport 68 Foundries 22 Agricultural tools 49 14 MUSEUMS 69 Wrought iron and water power 23 Other Edge Tools and Files 50 Index 70 Further reading 71 USING THIS BOOK South Yorkshire has a long history of industry including water power, iron, steel, engineering, coal, textiles, and glass. -
Solar Solutions Bristol Stickney, Technical Director, Cedar Mountain Solar Systems, Santa Fe, N.M
Solar Solutions Bristol Stickney, technical director, Cedar Mountain Solar Systems, Santa Fe, N.M. Bristol’s six principles of good solar hydronic design Basic Combi-System Controls In this series of articles, I have been making the case that the key become my basic standard piping arrangement for over a decade for ingredients for solar/hydronic design and installation can be divided Combi-system 101. There are a number of additional benefits when into six categories, listed below, roughly in order of their importance. using this system in real-world installations. The primary loop is typ- 1. RELIABILITY ically installed horizontally, hanging from the ceiling. The swing 2. EFFECTIVENESS check valves must me installed horizontally or “flow upward,” since 3. COMPATIBILITY they may not close properly if installed “flow downward.” 4. ELEGANCE For the purpose of this discussion, I will present the very simplest 5. SERVICEABILITY control system that will provide the homeowner with Reliable and 6. EFFICIENCY Effective use of the solar heat available from this sample heating The success of any solar hydronic home heating installation system. Keep in mind, that as a simple example, it does not include depends on the often-conflicting balance between any of these six night cooling, baseboard heat, heat storage tanks for space heating principles. Finding the balance between them defines the art of solar or other relatively common options. Each additional option would heating design. require additional control components to be included in our wiring n previous columns I have introduced and explained some of the and control system. So to keep this article brief we will limit the dis- elemental concepts of hydronic solar home heating. -
Supertherm (VS Series) Indirect Fired, Semi-Instantaneous, Steam and Boiler Water Heater (Vertically Built, Steam to Water with Electronic Or Pneumatic Controls)
Installation, Operation, and Maintenance Manual SuperTherm (VS Series) Indirect Fired, Semi-Instantaneous, Steam and Boiler Water Heater (Vertically Built, Steam to Water with Electronic or Pneumatic Controls) This manual applies to the following models: SuperTherm VS06_S2A SuperTherm VS08_S2A SuperTherm VS010_S2A SuperTherm VS012_S2A SuperTherm VS06_D2A SuperTherm VS08_D2A SuperTherm VS010_D2A SuperTherm VS012_D2A CONTRACTOR / FACILITY INFORMATION NOTE: This user manual must always accompany the specific unit as recorded below: Model #: _______________________________ Serial #: _______________________________ Install Date: ____________________________ DHT SUPERTHERM WATER HEATER Latest Update: 09/05/2018 DISCLAIMER The information contained in this document is subject to change without notice from Diversified Heat Transfer, Inc. (DHT). DHT makes no warranty of any kind in respect to this material, including, but not limited to, implied warranties of merchantability and fitness for a particular application. DHT is not liable for errors appearing in this document, nor for incidental or consequential damages occurring in connection with the furnishing, performance, or use of these materials. REV-3 Diversified Heat Transfer, Inc. 439 Main Road, Route 202 Towaco, New Jersey 07082 Page 1 of 90 SuperTherm Manual Phone: 800-221-1522 Website: www.dhtnet.com 02/24/2018 SUPERTHERM Install, Operation, and Maintenance Manual TABLE OF CONTENTS TABLE OF CONTENTS: SECTION 1: GENERAL INFORMATION ...................................................................................................