Pipette Resource Guide

Total Page:16

File Type:pdf, Size:1020Kb

Pipette Resource Guide PIPETTE RESOURCE GUIDE What to Know Before Buying Pipettes Time to Upgrade? Benefits of Electronic Pipettes A Guide to Proper Pipetting Tips for Ergonomic Pipette Use and Tips for Low-Volume Pipetting Featured Manufacturers Pipette Resource Guide How does the volume of samples being worked What to Know with influence which pipette is the best fit? Pipetting for high-throughput applications involves using your Before Buying thumb over and over again to push down on and release the piston on the pipette and then to eject the pipette tip. This Pipettes repeated movement can result in repetitive strain injuries. If your application requires a large amount of pipetting, consider Pipettes are used for the accurate transfer of liquids in the investing in an electronic pipette. These pipettes contain a motor preparation of reactions, experiments, and other solutions. These that precisely regulates aspiration and dispensing rates with handheld instruments are one of the most frequently used tools push-button functionality, limiting the force that must be exerted in the lab and you should consider ergonomics and the comfort by the user’s thumb to perform a pipetting task. They have the of your workers when purchasing. The right pipette can also help added advantage of reducing measurement error in experiments optimize your lab’s productivity. with many samples and replicates. What volume of samples will you be pipetting? Maintenance Tip Pipettes are specifically tailored to aspirate and dispense within certain volume ranges. It’s important to stay within the pipette’s Right out of the box, verify that your new volume range to prevent damage to the instrument. For this pipette has been properly calibrated. After reason, consider the volumes you will be pipetting before making purchasing decisions. Consistent calibration and maintenance of that, the frequency of calibration depends your pipettes will help ensure that your pipettes are aspirating on how often your pipette is used and and dispensing the correct volume, which is important especially how accurate you need it to be. Some labs when pipetting small volumes. For high volume pipetting in the partner with an outside provider for annual milliliter range, you’ll want to use a serological pipette with a controller. calibrations while performing interim verifications in-house. Look for calibration What is your sample throughput? as a provided service when purchasing. High-throughput applications like qPCR or ELISA use mi- croplates containing 24, 96, 384, or 1536 wells. Multi-channel pipettes have multiple pistons so you can aspirate and dispense liquids into multiple wells with a single pipette movement. Using multi-channel pipettes can help you prepare your samples faster while limiting the number of times you have to aspirate and dispense liquids, decreasing your chances of acquiring repetitive strain injuries like “pipette thumb.” Lab Manager 2 Pipette Resource Guide Regular pipette maintenance is important and how often it needs Time to to be done depends on how often the pipette is used, the types of solutions being pipetted, how many people are using the pipette, and if the user’s industry is regulated, the experts say. In general, Upgrade? yearly calibrations are recommended. Regular calibration will Liquid handling technology is help extend the life of the instrument and improve failure rates. always improving Upgrading a pipette really has only two cons: the up-front cost by Rachel Muenz to purchase and the time it takes to adjust to the new instrument. Pipettes can be very personal, and it can take time for a user to Pipettes. They can be found in almost every laboratory and, if get used to the touch and feel of a new pipette. you’re looking to buy one, there are many options— manual or electronic, single or multi-channel. Luckily, a few main considerations can help in deciding whether or not to buy the OPTIONS FOR USERS: latest pipette technology. First, a user should check their current with an unlimited budget pipettes to see if they are working properly and if they still fit the • Buy the latest and greatest technology available user’s needs. Consulting with vendors and their technicians is • Go for an electronic pipette—the increased also helpful. accuracy is worth it • Purchase a pipette that uses a positive Vendors can supply the most up-to-date replacement parts. It’s displacement system, which provides the best also likely you’ll get the lowest price by going directly to the precision and accuracy manufacturer to have a pipette repaired, calibrated, or checked. • If the budget is truly unlimited and the need is In addition, manufacturers can provide quotes so you can decide there, an automated system is the way to go whether it’s worth it to repair the pipette or more cost-effective to buy a new one. OPTIONS FOR USERS: Despite the up-front cost, buying new means better precision, with a tight budget accuracy, ergonomics, programming, and usability, so users can • Ensure pipettes are checked/maintained be more productive and save on reagent costs. The newest model frequently often includes new features that can improve performance even • Make sure to buy pipettes that are easy for users more. to maintain and calibrate themselves • Send current pipettes to a service center for a However, if users’ current pipettes aren’t causing any ergonomic quick check up (can be done for under $20) injuries, are still accurate, aren’t being used to pipette harsh • Check out the trade-in or lease programs solutions, and are being maintained and calibrated regularly, available there is probably no need to upgrade. In some cases, the pipette • Look into replacing several manual pipettes with might have been written into operating procedures, so it would one electronic one be difficult to change or upgrade. Lab Manager 3 Pipette Resource Guide and the industry itself, as it moved toward production of Benefits of microcentrifuges and graduated microvolume test tubes. More recent advances in pipetting technology stem from increased throughput in experimentation. The success of the Human Electronic Genome Project, and the rise of deep sequencing platforms, spurred companies to begin introducing electronic pipettes. Now, many laboratories have a range of pipetting options, with Pipettes electronic repeater and multichannel pipettes, and a full series of Electronic pipettes are the preferred solution for manual P20, P200, and P1000 pipettes for each staff member. efficiency, consistency, and reliability Choice can sometimes be an experimental hazard, though. It is frustrating to watch a student pipet vanishingly small volumes, for instance adding 0.27 microliters of an enzyme in 10 percent by Brandoch Cook glycerol to a reaction tube using a P2. Additionally, because of the ability of the manual piston to go past its point of measured A pipette is a thin tube used for transferring liquids, and has been accuracy, people erroneously take up volumes that exceed the an indispensable tool of science since the time of Pasteur. He and calibrated range. As manual pipettes are particularly vulnerable other Victorian-era scientists used bulbs, inlet tubes, and cotton to hysteresis, transfer of seemingly identical volumes to many wool filters to enhance suction and forestall contamination. samples is actually subject to a significant amount of error. Although their volumetric consistency was inadequate, these Finally, how can any of us over the age of 35 hope to be accurate adaptations spurred a leap forward in microbiology and allowed when we can’t even see the little tick marks in between the researchers to safely transfer liquids with their fingers instead of microliter values anymore? their mouths. Nonetheless, the first report of infection occurred contemporaneously, in 1893, when a researcher mouth-pipetted Electronic pipettes contain a motor to precisely regulate the bacterium that causes typhoid. The victim was a sentinel for trends to come, and by the 1950s up to 40 percent of laboratory- aspiration and dispensing rates, which reduces air bubbles derived infections were caused by mouth pipetting. A 1966 US and barrel contamination. Moreover, repeater pipettes reduce Army study came to the obvious conclusion that researchers measurement error in experiments with many samples and should stop doing it. Heedless of this advice, bacterial and replicates. Push-button functionality provides an ergonomic viral infections, radioactive poisoning, and chemical burns advantage, avoiding mechanical wear associated with force- were common occurrences until the 1970s, when precision dependent actions like tip ejection, and obviating laboratory micropipettes became widespread. casualties like pipette thumb. Electronic pipettes are often programmable, allow storage and modification of protocols, save The manual, piston-stroke micropipette was introduced by on overall tip usage, and drive greater efficiency in experimental Eppendorf in 1961 and marked significant improvements in setup. Several providers have taken the technology a step further accuracy and standardization compared to previous iterations, and created linked smart pipetting systems. Manufacturers now oral or otherwise, which depended on forces of suction and offer pipettes that are programmable and Bluetooth-enabled, expulsion that were unique to each user. Gilson later updated allowing them to keep track of complex multi-well pipetting the technology to allow for adjustable volume control. The tasks in real time and store data for further analysis. Finally, introduction of instruments oriented toward microliter amounts although electronic pipettes are usually two to three times helped drive biomedical science into the realm of the very small. the price of manual ones, the increased accuracy, and hence It changed investigators’ approaches to scientific questions, efficiency and confidence in results, are well worth it. Lab Manager 4 Pipette Resource Guide Product Spotlight Thermo Scientific ClipTip Pipetting System The Thermo ScientificTM ClipTipTM Pipetting System will help save you time and increase your efficiency through improved ergonomics, fewer mistakes and reproducible results.
Recommended publications
  • Laboratory Equipment Reference Sheet
    Laboratory Equipment Stirring Rod: Reference Sheet: Iron Ring: Description: Glass rod. Uses: To stir combinations; To use in pouring liquids. Evaporating Dish: Description: Iron ring with a screw fastener; Several Sizes Uses: To fasten to the ring stand as a support for an apparatus Description: Porcelain dish. Buret Clamp/Test Tube Clamp: Uses: As a container for small amounts of liquids being evaporated. Glass Plate: Description: Metal clamp with a screw fastener, swivel and lock nut, adjusting screw, and a curved clamp. Uses: To hold an apparatus; May be fastened to a ring stand. Mortar and Pestle: Description: Thick glass. Uses: Many uses; Should not be heated Description: Heavy porcelain dish with a grinder. Watch Glass: Uses: To grind chemicals to a powder. Spatula: Description: Curved glass. Uses: May be used as a beaker cover; May be used in evaporating very small amounts of Description: Made of metal or porcelain. liquid. Uses: To transfer solid chemicals in weighing. Funnel: Triangular File: Description: Metal file with three cutting edges. Uses: To scratch glass or file. Rubber Connector: Description: Glass or plastic. Uses: To hold filter paper; May be used in pouring Description: Short length of tubing. Medicine Dropper: Uses: To connect parts of an apparatus. Pinch Clamp: Description: Glass tip with a rubber bulb. Uses: To transfer small amounts of liquid. Forceps: Description: Metal clamp with finger grips. Uses: To clamp a rubber connector. Test Tube Rack: Description: Metal Uses: To pick up or hold small objects. Beaker: Description: Rack; May be wood, metal, or plastic. Uses: To hold test tubes in an upright position.
    [Show full text]
  • Rhodamine B Lipase/Esterase Agar
    ALKEN-MURRAY CORPORATION TI TLE: RHODA M INE B A GA R NO. QC-99 PREPARA TI ON PROCEDURE MICROBIOLOGICAL DIVISION QUALITY CONTROL REV : 3 PAGE 1 OF 4 ALKEN-MURRAY CORPORATION P. O. Box 400, New Hyde Park, NY 11040 TELEPHONE 540-636-1236 - Fax 540-636-1770 QUALITY CONTROL METHOD - 99 Preparation and Use of Rhodamine B Lipase Agar Description: This quality control procedure is designed to verify that Rhodamine B Agar is properly prepared, used and stored. This procedure demonstrates the ability of some bacteria to produce lipase and degrade food oils, such as olive oil, in a clear and easily interpreted manner. We found that the Spirit Blue method (QC-94) was harder to interpret, leading to misinterpreted results. This procedure should be performed by a trained laboratory technician. Ingredients: For lipoidal emulsion (50 ml per 450 ml of base medium) - enough lipoidal emulsion for 1 liter: Olive oil 30 ml Tween 80 250 µl Distilled water 50 ml 1 Rhodamine B 20 mg/20 ml sterile water (0.02% w/v total media prepared) 1. Add filter sterilized Rhodamine B solution, after autoclaving other ingredients For base medium: Nutrient Broth 4.5 g (alternate Peptone water) Yeast extract 1.25 g Agar 10 g Distilled water 450 ml Final pH 7.0 ± 0.2 Equipment and Supplies: 500 ml Graduated cylinder 50 ml Graduated cylinder 1 ml sterile syringe with 18 gauge needle 10 ml sterile syringe with 18 gauge needle 10 ml sterile serological pipet Drummond Pipet-Aid® or rubber bulb 2 - 50 ml sterile serological pipets ALKEN-MURRAY CORPORATION TI TLE: RHODA M INE B A GA R NO.
    [Show full text]
  • Oxidation of 9-Fluorenol to 9-Fluorenone with Sodium Hypochlorite
    CHEM 2229 EXP 1: Oxidation of 9-Fluorenol to 9-Fluorenone with Sodium Hypochlorite Objective: In this experiment you will learn how to perform an oxidation reaction by oxidizing an alcohol (9- hydroxyfluorene) to a ketone (9-fluorenone) using sodium hypochlorite in an acidic environment; how to perform TLC to monitor a reaction; how to perform an extraction to isolate a product; and, how to verify purity of a product using TLC and melting point. * Chromatography is a useful method for separating components of a mixture of compounds based on their polarity. Thin layer chromatography is especially useful for determining the number of components in a mixture, the identity of the compounds, and the purity of a compound. **Solvent Extraction is also known as Liquid–liquid extraction (LLE) or partitioning. It is a method used to separate compounds based on their relative solubilities in two different immiscible liquids: usually the polar solvent water and a non-polar organic solvent. Immiscible means that the liquids do not mix and because of this form two distinct layers. ***The melting point (MP) is a physical property of a solid also used for the purpose of identification and purity determination. Reading Assignment: OCLT: OCLT, pp. 83-108 (chromatography generalities & TLC), pp. 368-369 (TLC technique summary), pp. 203-246 (extraction); pp. 376-381 (extraction illustrations); 366 (vacuum filtration); and 309-315 (melting point). Solomons Organic Chemistry, 12th ed. (Note: Pages correspond to 12th ed.) pp. 542-547 (12.4 Oxidation of Alcohols) Concepts: Acids, Bases, Decantation, Drying Agents, Exothermic Reactions, Extraction, Half Cell Method, Oxidation/Reduction, Oxidizing Agents, Reducing Agents, Reflux, Salting Out Chemicals: acetic acid (glacial), acetone, 9-fluorenol, 9-fluorenone, hexane, sodium bicarbonate, sodium chloride, sodium hypochlorite (aq soln) / bleach, sodium sulfate Safety Precautions: Wear chemical splash-proof goggles and appropriate attire at all times.
    [Show full text]
  • Determination of Kinematic Viscosity of Different Biodiesel Fuels at Various Temperatures
    DETERMINATION OF KINEMATIC VISCOSITY OF DIFFERENT BIODIESEL FUELS AT VARIOUS TEMPERATURES. A THESIS SUBMITTED TO THE GRADUATE SCHOOL OF APPLIED SCIENCES OF NEAR EAST UNIVERSITY by IBUKUN OLUWOYE In Partial Fulfillment of the Requirements for the Degree of Master of Science in Mechanical Engineering NICOSIA 2013 Ibukun Oluwoye: DETERMINATION OF KINEMATIC VISCOSITY OF DIFFERENT BIODIESEL FUELS AT VARIOUS TEMPERATURES. Approval of Director of Graduate School of Applied Sciences Prof. Dr. I˙lkay SALI˙HO ĞLU We certify that this thesis is satisfactory for the award of the degree of Master of Science in Mechanical Engineering Examining Committee in Charge: DECLARATION I hereby declare that all information in this document has been obtained and presented in accordance with academic rules and ethical conduct. I also declare that, as required by these rules and conduct, I have fully cited and referenced all material and results that are not original to this work. Name: Ibukun Oluwoye Signature: Date: i ABSTRACT Fatty acid composition has a significant effect on the viscosities of fats and oils and in turn biodiesel fuels. The fatty acid composition of fats and oils are feedstock dependent and are also affected by factors such as climatic conditions, soil type, and plant health and maturity upon harvest. Due to the reasons mentioned, there is a need to determined major fuel properties locally for biodiesel samples. The viscosity of five biodiesel fuel in Northern Cyprus are measured up to temperature 140˚C; temperature just above the flash point of biodiesel fuel proposed by ASTM. The temperature – viscosity relationship was determined together with temperature – mixing percentages composition relationship Keyword: Fuel, Biofuels, Biodiesel, Viscosity, Density, Green Energy, Frying Oil, Canola Oil ii ACKNOWLEDGEMENTS Firstly, my sincere appreciation is to God for the gift of life and balances in which all ingenuity is defined in me.
    [Show full text]
  • A Pipette Method of Mechanical Analysis of Soils Based on Im- Proved Dispersion Procedure
    TECHNICAL BULLETIN NO. 170 JANUARY, 1930 UNITED STATES DEPARTMENT OF AGRICULTURE WASHINGTON, D. C. A PIPETTE METHOD OF MECHANICAL ANALYSIS OF SOILS BASED ON IM- PROVED DISPERSION PROCEDURE By L. B. OLMSTEAD, Physicist^ LYLE T. ALEXANDER, Junior Physicist, and H. E. MiDDLETON, Associate Physicistj Division of Soil Chemistry and Physics, Soil Investigations^ Bureau of Chemistry and Soils ^ CONTENTS Page Introduction 1 Outline of method _ 14 Dispersion _ 3 General statement 14 Hydrogen peroxide treatment— 3 Preparation and dispersion of sample 15 Acid treatment—. 5 Separation into size classes 15 Washing 9 Calculation of results _.- 18 Dispersing agents 9 Apparatus _ 19 Electrodialysis--. 11 Summary 20 Shaking .-. 11 Literature cited 21 Separation into size classes 12 Size classes employed 12 Method of separation 13 Sedimentation velocity and particle size. 13 INTRODUCTION In all methods of mechanical soil analysis some separations are based on the well-known fact that the smaller particles in water suspensions fall more slowly than larger ones. In elutriation methods the smaller particles are borne upward by a rising water column while larger particles fall. In the early work of the Bureau of Soils the Osborne (20y beaker method was used to make silt and clay separations. Whitney (5) apparently was the first to use the centri- fuge to increase the settling velocities of soil particles. The centri- fuge method was then worked out independently by Hopkins (12) and Snyder (27), In 1904 the Bureau of Soils published its centri- fuge method (5)j which with modifications (9) has been used until recently. The centrifuge method was much more rapid than the beaker method and gave better dispersion than elutriation methods.
    [Show full text]
  • Laboratory Equipment AP
    \ \\ , f ?7-\ Watch glass 1 Crucible and cover Evaporating dish Pneumatlo trough Beaker Safety goggles Florence Wide-mouth0 Plastic wash Dropper Funnel flask collecting bottle pipet Edenmeyer Rubber stoppers bottle flask € ....... ">. ÿ ,, Glass rod with niohrome wire Scoopula (for flame re,sting) CruoiNe tongs Rubber ubing '1 ,v .... Test-tube brush square Wire gau ÿ "\ file Burner " Tripod Florence flask: glass; common sizes are 125 mL, 250 mL, 500 .d Beaker: glass or plastic; common sizes are 50 mL, mL; maybe heated; used in making and for storing solutions. 100 mL, 250 mL, 400 mL; glass beakers maybe heated. oÿ Buret: glass; common sizes are 25 mL and 50 mL; used to Forceps: metal; used to hold or pick up small objects. Funnel: glass or plastic; common size holds 12.5-cm diameter measure volumes of solutions in titrafions. Ceramic square: used under hot apparatus or glassware. filter paper. Gas burner: constructed of metal; connected to a gas supply Clamps" the following types of clamps may be fastened to with rubber tubing; used to heat chemicals (dry or in solution) support apparatus: buret/test-tube clamp, clamp holder, double buret clamp, ring clamp, 3-pronged jaw clamp. in beakers, test tubes, and crucibles. Gas collecting tube: glass; marked in mL intervals; used to 3: Clay triangle: wire frame with porcelain supports; used to o} support a crucible. measure gas volumes. Glass rod with nichrome wire: used in flame tests. Condenser: glass; used in distillation procedures. Q. Crucible and cover: porcelain; used to heat small amounts of Graduated cylinder: glass or plastic; common sizes are 10 mL, 50 mL, 100 mL; used to measure approximate volumes; must solid substances at high temperatures.
    [Show full text]
  • Lab Equipment Beaker
    Lab Equipment Beaker Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated. They come in a variety of sizes and the measurements on them are a guideline only. They are very inaccurate! Erlenmeyer Flask Erlenmeyer flasks hold solids or liquids that may release gases during a reaction or that are likely to splatter if stirred or heated. Volumetric Flask Volumetric Flasks are very accurate containers that are used to make solutions of a very precise concentration. They come in a wide variety of sizes. Solutions should never be stored in a volumetric flask, just prepared in them. Büchner Funnel A Büchner funnel is a piece of laboratory equipment which is used to filter or separate a solid from a liquid. It allows the solid to be dried faster than simply using a filter paper over a beaker as the vacuum aids in removing water. Graduated Cylinder A graduated cylinder is used to measure volumes of liquids. The are accurate to 1 decimal place. What’s the purpose of the yellow band at the top? Test Tubes 13 x 100 mm test tubes 10 x 75 mm test tubes Test Tube Holder A test tube holder is useful for holding a test tube which is too hot to handle. Test Tube Brushes Test tube brushes are used to clean test tubes and graduated cylinders. Forcing a large brush into a small test tube will often break the tube. Test Tube Racks Test tube racks are for holding and organizing test tubes on the laboratory counter.
    [Show full text]
  • United States Department of the Interior, J. A. Krug, Secretary Fish
    . United States Department of the I nterior, J. A. Krug , Secretary Fish and Wildli fe Service , Albert M. Day , Dir ector ** ******** Fi shery Leafle t 138 Washi ngton 25, D. C. Reissued June 1948 • • SOME TIME AND LABOR SAVING TECHNIQUES IN VI TAMI N A AND OIL ANALYSES By F. B. Sanford*, G. C. Bucher**, and W. Clegg* I n the course of an ext ens ive study of the factors affecting the potency of the dog­ fish l i ver oils, made in collaboration with the Washington State Fisheries, there were de­ veloped a numb er of time and labor saving techniques such 8S are discussed by Bjorksten!!. These ma y prove of interest ~o other laboratories in the oil and vitamin f ields. Use of · Mal ted Milk Mixer--Li ver homogenization has been made easy by means of a blender. However, wi th these machines it is difficult to handle livers weighing l ess t han one ounce. because the blades of the blender do not engage the liver. In this case, a malted milk mixer becomes valuable. Even small fetal livers can be homogenized by its use. An­ other advantage is that small liver samples can be. disintegrated while in their 'original containers. If insufficient cutting is obtained with the agitators furnished with the mixer, they can be replaced by cutters of almost any size and shape made from hacksaw blades sharpened on one edge. (Figure 1) Weighing Wires-- The advantage of weighing wires in handling the small quantities of oil usually em­ '::::..~~ ~..:--. ployed in Vitamin A analyses has been known for some time.
    [Show full text]
  • Lab Equipment Lab Equipment
    Lab Equipment Lab Equipment Your lab equipment should: 1. Be CLEAN before using it. 2. Be CHECKED (if glassware) for cracks, broken edges, and “stars”– discard anything damaged. Pre-AP Chemistry Charles Page High School 3. Be washed, dried, and carefully stored in the Stephen L. Cotton proper place after using it. Cleaning Supplies 1. Each lab station has plenty of paper towels, soap, water, sponge and a sink. (2 sinks are also located on the east wall desktop) 2. Used for cleaning lab equipment, the table top, and to wash your hands when finished. 3. We have floor brooms, table brushes, and dustpans to clean up any spills. Keep our lab area neat and clean! Beakers hold and/or heat solids or liquids Beaker Use this Broken Glass that will not release box to dispose of any gases when reacted, or are unlikely to broken glass, instead splatter if stirred. of the trash can. Very poor item to measure volume with (+/- 5% error!) Note the total size There are six sizes of beakers in capacity = 250 mL your lab table for you to use: (upper mark is 200 mL) 50, 100, 150, 250, 400, & 600 mL 1 Beaker Tongs Beaker tongs are used to hold Erlenmeyer Flask and move beakers Erlenmeyer flasks containing hot hold and/or heat liquids. solids or liquids that may release Note the rubber gases during a coating to reaction, or that are improve grip on likely to splatter if the glass beaker stirred. - do not hold these in a burner flame. Note the size = 125 mL Florence Flask Flask Tongs Rarely used in first year chemistry, it is used for the mixing of chemicals.
    [Show full text]
  • Microbiology II-99
    Protocoll-Mari 1/24 15.02.01 Microbiology II-99 Selected experiments for advanced Microbiology Protocol Nov 8th till 13th 1999 Headed by: Prof. Dr. H. Stan-Lotter Tutors: Michaela Eder Renate Marschon Handed by : Maricela Yip Salzburg, December 13th, 1999 Protocoll-Mari 2/24 15.02.01 Table of Contents Page Introduction Sterilization and Aseptic Techniques..................... 3 Experiment 1 Bacteria in natural Biotopes Bacterial sample from the Human Body................ 4 Bacterial sample from water................................. 5 Bacterial sample from the Air................................ 7 Experiment 2 Microbes in untreated samples of Milk I............... Medium broth to promote bacterial growth........... 9 Dilution series of raw milk sample........................ 9 Discussion.............................................................. 10 Experiment 3 Microbes in untreated samples of Milk II Bacterial proliferation in a sample of raw milk over a period of several days................................. 11 Experiment 4 Relation of free oxygen and microbial growth I Relation of oxygen concentration in a solid medium to types of microbial growth.................... 12 Experiment 5 Relation of free oxygen and microbial growth II Relation of oxygen concentration in a solid medium to types of microbial growth.................... 13 Discussion.............................................................. 14 Experiment 6 Extremophile Microbes Cultivation, growth, and examination of a thermo-acidophile Archae-bacterium....................
    [Show full text]
  • Delineation of Background Laboratory Contamination in the Analysis Of
    U.S. DEPARTMENT OF THE INTERIOR U.S. GEOLOGICAL SURVEY DELINEATION OF BACKGROUND LABORATORY CONTAMINATION IN THE ANALYSIS OF TRACE CONCENTRATIONS OF EXTRACTABLE ORGANIC MATERIALS IN CRYSTALLINE ROCKS BY SOXHLET EXTRACTION, COLUMN CHROMOTOGRAPHY, AND GAS CHROMATOGRAPHY By Koichi Mimura1 and Leigh C. Price2 Open-File Report 99-335 1999 This report is preliminary and has not been reviewed for conformity with U.S. Geological Survey editorial standards. Use of brand or trade names in this report are for descriptive purposes only and do not imply either endorsement or non-endorsement by the U.S. Government. Department of Earth and Planetary Sciences, Nagoya University, Nagoya, 464-01, Japan 2U.S. Geological Survey, Denver Federal Center Denver, CO 80225, USA 1.0 Abstract.................................................................................... 2 2.0 Introduction................................................................................. 2 3.0 Analytical Method......................................................................... 3 4.0 Contamination Checks..................................................................... 5 4.1 Solvents................................................................................ 5 4.11 Dichloromethane............................................................ 6 4.12 Hexane....................................................................... 11 4.13 Benzene...................................................................... 14 4.14 Benzene Methanol.........................................................
    [Show full text]
  • Vitamin D2,D3
    Biochemical Diagnostics, Inc. 180 Heartland Blvd, Edgewood, NY 11717● Phone (800) 223-4835 Fax (631) 595-9204 ● www.biochemicaldiagnostics.com MULTI-PREP® GV-65C MIXED BED (CATION EXCHANGE/NON IONIC) METHOD FOR THE ANALYSIS OF 25-HYDROXY-VITAMIN D2 AND 25-HYDROXY-VITAMIN D3 IN SERUM BY GC/MS or LC/Tandem MS September 2008 SAMPLE PREPARATION - (Please see Notes and SAMPLE ELUTION Supplemental Information before proceeding) Elute with 0.4 mL Methanol 1. Pipette 0.2-0.5 mL of serum plus internal standard Note: If a sample does not elute freely by gravity flow, there is into a disposable borosilicate glass tube. Mix. either air trapped within the column bed or frits or aqueous phase remaining on the column because of weak vacuum HARDWARE SETUP - (Please refer to the Detectabuse during the column drying step. In most cases, tapping the Hardware Setup Instructions) column will initiate flow. If this does not do the job, use a rubber bulb to gently push a few drops of elution solvent and COLUMN CONDITIONING trapped air into the collection tube. Allow the remainder of solvent to flow by gravity. 1. Wash column with 1.0 mL of Methanol. Allow to flow by gravity. A. FOR LC/MS/MS 2. (Optional) Wash column with 1.0 mL Methanol:Water 1. Add 0.1 mL of Water to eluate, (75:25). Allow to flow by gravity. 2. Mix and inject . 3. Wash column with 1.0 mL Methanol:Water (50:50). B. FOR GC/MS DERIVATIZATION Allow to flow by gravity. 0 1. Dry down eluate at less than 50 C 2 Add 75 µL Ethyl Acetate, 25 µL TMSI to each dried extract SAMPLE DEPROTEINIZATION 0 3.
    [Show full text]