Eden Kim, Calypso Systems, Inc

Total Page:16

File Type:pdf, Size:1020Kb

Eden Kim, Calypso Systems, Inc Session 303-B SNIA SSSI PCIe SSD Round Table Thursday, August 23, 2012 3:10 pm- 4:25 pm Eden Kim, Chair Santa Clara, CA August 2012 1 Tuesday, August 28, 12 PCIe Solid State Storage - Higher Performance / Lower Latencies Solid State Storage PCIe . a Round Table What are issues facing Adoption of PCIe Solid State Storage devices? • Standards for PCIe Attached Storage • Technology & Architectural Issues • Mass Storage Ecosystem Adoption & Optimization • Market & Product Positioning • Deployment Strategies Santa Clara, CA August 2012 2 Tuesday, August 28, 12 Panelists - Session 303-B Moderator: Eden Kim, Calypso Systems, Inc. 3:10 – 3:15: Eden Kim, Calypso - IntroducLon Speakers 3:15 – 3:20: Easen Ho, Calypso – PCIe Performance TesLng 3:20 – 3:25: Gary Orenstein, Fusion-io – Lessons from the Front Lines & A Look to the Future 3:25 – 3:30: Paul Wassenberg, MarVel – SATA Express 3:30 – 3:35: Mark Myers, Intel – SFF Working Group – PCIe 2.5” Form Factor 3:35 – 3:40: Marty Czekalski, Seagate – SCSI Express: Extending the SCSI PlaZorm 3:45 – 3:50: Don Jeane\e, Toshiba – PCIe LoVe & Stuff that needs to Happen 3:50 – 3:55: Tony Rogue, Virident – PCIe & Storage Class Memory QuesLon & Answer Session – 3:55 – 4:10 Audience QuesLons 9:40 – 9:50: Please fill out QuesLonnaire Cards Santa Clara, CA August 2012 3 Tuesday, August 28, 12 SNIA SSSI PCIe SSD Task Force Open Forum April – July 2012 62 Companies 130 Individuals •SSD OEMs ODMs •Controller Companies •Semiconductor Fabs C LABS •VARs, SAN, NAS •Analysts, Blogs •Industry Associations •Standards Groups •End Users Paul Mitchell Santa Clara, CA August 2012 4 Tuesday, August 28, 12 SNIA SSSI PCIe SSD Task Force 8 MEETINGS 24 PRESENTATIONS PRESENTING COMPANIES TOPICS HP - Marvell - Micron – Toshiba - Seagate • Standards • Testing & Instrumentation STEC - Fusion-io - Virident - Intel • PCIe Performance NVMe - SATA-IO – STA - PCI SIG • System Integration • Form Factors Calypso – Agilent – HyperIO - LeCroy – eASIC • System Architectures • PCIe Driver Topics Coughlin Associates - Objective Analysis • Analysts View SNIA IOTTA – NVMP – SSS - Security TWGs • Market Development • Deployment Strategies PresentationsSanta Clara, CA can August be downloaded in mtg minutes at www.snia.org/forums/sssi/pcie 2012 5 Tuesday, August 28, 12 PCIe SSD Standards ITEM GROUP STANDARD CLIENT PCIe SSD ENTERPRISE PCIe SSD PCI-SIG PCI Express PHYSICAL up to 2 LANES Drive SATA-IO SATA Express Up to 4 LANES INTERFACE up to 4 LANES Card SCSI Trade Assn SCSI Express REGISTER Intel AHCI SOP / PQI INTERFACE & NVM Express Group NVMe AHCI or NVMe Or SOP / NVMe COMMAND SET T10 SOP/PQI w/support for NVMe Or NVMe SATA-IO SATA Express SATA Express HOST CONNECTOR SSD FF WG multifunction connector Host Connector SFF-8639 Small FF CommiIee SFF-8639 Or SFF-8639 SATA-IO SATA Express DEVICE SATA Express SSD FF WG multifunction connector SFF-8639 CONNECTOR Drive & Card Connectors Small FF CommiIee SFF-8639 Advancing Solid State Storage Tuesday, August 28, 12 Panelist Easen Ho, Calypso Speaker Company Introductory Name Title Bio Easen Ho Calypso Dr. Ho is the CTO of Calypso Systems, Inc. and has been a principal architect of the recently released SNIA Solid State Storage Performance Test Specificaon. Dr. Ho has CTO been in\mately involved in the development of performance benchmarking for NAND [email protected] Flash based solid state storage devices. m Dr. Ho received his doctorate in laser physics from MIT and his BSEE from the Tokyo Ins\tute of Technology. Dr. Ho previously was founder, CEO and CTO of digital papyrus, inc., a laser op\cal mass storage technology firm. Santa Clara, CA August 2012 7 Tuesday, August 28, 12 PCIe SSD Roundtable Testing of PCIe SSDs Easen Ho CTO, Calypso Systems, Inc. Santa Clara, CA August 2012 8 Tuesday, August 28, 12 PCIe SSD Testing Issues § From a testing perspective, PCIe SSDs looks just like another drive to the application, however… •Generally targeted at high end à faster TP, IOPS, and latencies •Wider variety of architectures possible: – no longer gated by a specific protocols such as SATA/SAS à possible to reduced IO latencies – host system can become part of the drive by design in some architectures à additional testing metrics needed; standardization becomes important •Variety of form factors à heat dissipation; power measurement issues •Variety of protocol standards à how do they affect performance? Santa Clara, CA August 2012 9 Tuesday, August 28, 12 Santa Clara, CA August 2012 10 Tuesday, August 28, 12 Santa Clara, CA August 2012 11 Tuesday, August 28, 12 Santa Clara, CA August 2012 12 Tuesday, August 28, 12 Santa Clara, CA August 2012 13 Tuesday, August 28, 12 Santa Clara, CA August 2012 14 Tuesday, August 28, 12 Panelist Gary Orenstein, Fusion-io Speaker Company Introductory Name Title Bio Gary VP Products Gary has served in leadership roles at numerous data center infrastructure Orenstein companies. Prior to Fusion-io he was the vice president of marketing at MaxiScale, focused on web scale file systems and acquired by Overland Storage. Prior to MaxiScale, he was the vice president of marketing and business development at Gear6, focusing on storage and web caching. He also served as vice president of marketing at Compellent which went public and 2007, and was a co-founder at Nishan Systems, acquired by McDATA/ Brocade Santa Clara, CA August 2012 15 Tuesday, August 28, 12 August 23, 2012 Lessons from the Front Lines and a Look to the Future Gary Orenstein, SVP of Products, Fusion-io, @garyorenstein Tuesday, August 28, 12 Initial Stage of NAND Flash deployment Applications Block I/O NAND FLASH August 28, 2012 17 Tuesday, August 28, 12 Architectural Differences Applications Block I/O Architected like Architected like a disk memory August 28, 2012 18 Tuesday, August 28, 12 Memory-like Architecture Applications Block I/O J SSD approach Flash as Memory approach August 28, 2012 19 Tuesday, August 28, 12 Beyond Block I/O Access Applications Block and Block I/O Memory Enhanced I/O SSD SAS Flash as Memory SATA August 28, 2012 20 Tuesday, August 28, 12 August 28, 2012 Fusion-io Confidential 21 Tuesday, August 28, 12 August 28, 2012 Fusion-io Confidential 22 Tuesday, August 28, 12 S3 API – Bucket and Object operations DELETE Bucket DELETE Object DELETE Bucket lifecycle Delete Multiple Objects DELETE Bucket policy GET Object DELETE Bucket website GET Object ACL GET Object torrent GET Bucket (List Objects) HEAD Object POST Object GET Bucket acl GET Bucket lifecycle PUT Object GET Bucket policy PUT Object acl GET Bucket location PUT Object – Copy Initiate Multipart Upload GET Bucket logging GET Bucket notification Upload Part GET Bucket Object versions Upload Part – Copy GET Bucket requestPayment Complete Multipart Upload Abort Multipart Upload GET Bucket versioning List Parts GET Bucket website HEAD Bucket List Multipart Uploads PUT Bucket PUT Bucket acl; PUT Bucket lifecycle PUT Bucket policy; PUT Bucket logging PUT Bucket notification; PUT Bucket requestPayment PUT Bucket versioning; PUT Bucket website August 28, 2012 Fusion-io Confidential 23 Tuesday, August 28, 12 August 28, 2012 Fusion-io Confidential 24 Tuesday, August 28, 12 August 28, 2012 Fusion-io Confidential 25 Tuesday, August 28, 12 Software Development Kit ADVANTAGES APPLICATION Application source code Conventional access Direct access I/O Memory access Transactiona Transpare Auto Native Key-Value l Logging nt Memory Commit File Pair Simple Network Simple Block Extension Memory™ Block File Block Proprietary Storage OS Flash Virtualization Layer Storage Media Storage Media Traditional Storage Software Defined Storage August 28, 2012 Fusion-io Confidential 26 Tuesday, August 28, 12 Flash Deployment Architectures August 28, 2012 Fusion-io Confidential 27 Tuesday, August 28, 12 A NEW APPROACH IS NEEDED Performance $ 1990 July, 2012 Fusion-io Confidential 28 Tuesday, August 28, 12 A NEW APPROACH IS NEEDED $$$ Performance $ 1990 2000 July, 2012 Fusion-io Confidential 28 Tuesday, August 28, 12 A NEW APPROACH IS NEEDED $ $$$ Performance $ 1990 2000 2010 July, 2012 Fusion-io Confidential 28 Tuesday, August 28, 12 The Power of A SAN July, 2012 Fusion-io Confidential 29 Tuesday, August 28, 12 The Power of A SAN IN A 1 U SERVER July, 2012 Fusion-io Confidential 29 Tuesday, August 28, 12 acceleration solutions Direct Shared Caching Performance Native Flash Memory Interoperability August 28, 2012 Fusion-io Confidential 30 Tuesday, August 28, 12 Market Growth Accelerators August 28, 2012 Fusion-io Confidential 31 Tuesday, August 28, 12 Thank You @garyorenstein Tuesday, August 28, 12 Panelist Paul Wassenberg, Marvell Speaker Company Introductory Name Title Bio Paul MarVell Paul Wassenberg has over 20 years of experience in data storage and has Wassenberg been deeply involved with storage interface technology, including SATA since its inception. Early in his career, he was a storage controller designer, before moving into Marketing in the HDD industry, and eventually into storage semiconductors. Paul currently holds the position of Director, Product Marketing with Marvell Semiconductor. In that role, he has responsibility for transceiver technology and HDD/SSD storage standards. He is on the SATA-IO board of directors and chairs the SNIA Solid State Storage Initiative. Paul holds BSEE and MBA degrees from San Jose State University. Santa Clara, CA August 2012 33 Tuesday, August 28, 12 SATA Express Evolving SATA for High-Speed Storage Paul Wassenberg SATA-IO Marketing Chair Santa Clara, CA August 2012 34 Tuesday, August 28, 12 SATA is Everywhere SATA
Recommended publications
  • Flash Performance for Oracle RAC with Pcie Shared Storage
    Flash Performance for Oracle RAC with PCIe Shared Storage A Revolutionary Oracle RAC Architecture Authored by: Estuate & Virident | HGST Table of Contents Introduction ................................................................................................................................................. 1 RAC “Share Everything” Architecture ........................................................................................................... 1 Oracle RAC on FlashMAX PCIe SSDs ............................................................................................................. 3 RAC cluster with Virident | HGST FlashMAX ................................................................................................ 4 ASM and Oracle files .................................................................................................................................... 6 The Architecture Advantage ........................................................................................................................ 6 The Write Advantage (50% less I/O traffic through the network) ............................................................... 7 The Read Advantage (100% reads from local PCIe, Zero traffic through vShare network) .......................... 8 High Availability ............................................................................................................................................ 8 Performance ................................................................................................................................................
    [Show full text]
  • Western Digital Acquires Virident
    Western Digital Acquires Virident Whopping $685 Million Purchase Price Disk drive maker Western Digital Corp announced on 9 September 2013 that it is buying Virident Systems, Inc. which will be merged into HGST, a wholly- owned subsidiary of Western Digital.. Virident will be acquired for approximately $685 million in cash, consisting of about $645 million in enterprise value, net of Virident’s estimated cash balance. Virident believes its integration with HGST will strengthen its marketing by leveraging HGST’s strong brand, extensive channel relationships, and global customer reach. Who is Virident? Virident is a small independent manufacturer of very high end PCIe SSDs. The company has, from the beginning, had a relentless focus on consistency of performance, which is one aspect of SSDs that has received very little attention until recently. Virident started out as a manufacturer of two high-performance dedicated appliances, one for running MySQL database software, and the other to support the open-source memcached storage network caching software. Virident and competitor Schooner both entered this market at the same time. Both found that data centers were moving away from dedicated hardware and toward virtualization, forcing both companies to revise their plans. Schooner focused on software optimization and was recently acquired by SanDisk. Virident migrated to NAND flash-based PCIe SSDs similar to, but faster than, those pioneered by Fusion-io. It was able to do this because its original appliances were based on NOR flash, a very badly-behaved technology when it comes to write cycles. Virident applied its superior understanding of flash write cycle management to NAND and achieved superior results.
    [Show full text]
  • Virtual Desktop Scalability and Performance with Vmware View 5.2 and Virident Flashmax Ii Storage
    VIRTUAL DESKTOP SCALABILITY AND PERFORMANCE WITH VMWARE VIEW 5.2 AND VIRIDENT FLASHMAX II STORAGE Whether you are planning to make the move to desktop virtualization or are looking to expand your existing virtual desktop infrastructure (VDI), it is important that you choose the right software and storage for your enterprise environment. It is also vital to be able to add hardware and predictably scale your environment so that you know how many users you can expect to support as your VDI needs grow. Choosing VMware View 5.2 software with a fast and reliable internal storage solution, such as Virident FlashMAX II™ storage devices, can maximize performance, reduce latency, and scale predictably as you add users. In the Principled Technologies labs, we found that a single server running VMware View 5.2 virtual desktops with two low-profile Virident FlashMAX II storage devices could support 162 virtual desktops with nearly no latency to provide an excellent experience for end users. To verify how predictably and linearly this solution scales, we had only to add another server; two servers, each with two Virident devices, scaled perfectly to support 324 users. We also ran a storage-intensive recompose job on the desktops and found that Virident FlashMAX II devices could handle heavy maintenance jobs without sacrificing end-user performance. JANUARY 2013 A PRINCIPLED TECHNOLOGIES TEST REPORT Commissioned by VMware, Inc. and Virident Systems, Inc. MANY USERS, VERY LOW LATENCY, AND PREDICTABLE SCALABILITY The success of a virtual desktop environment is dependent on the number of enterprise users your solution supports, the performance and response times it provides for your users, and the ability to predict the number of users you can expect to support when you scale your hardware.
    [Show full text]
  • Ipr2017-00868
    United States Patent No. 7,827,370 IN THE UNITED STATES PATENT AND TRADEMARK OFFICE –––––––––– BEFORE THE PATENT TRIAL AND APPEAL BOARD –––––––––– SanDisk LLC Petitioner v. Memory Technologies, LLC Patent Owner –––––––––– Patent No. 7,827,370 –––––––––– PETITION FOR INTER PARTES REVIEW UNDER 35 U.S.C. § 311, 37 C.F.R. §§ 42.100 ET SEQ. United States Patent No. 7,827,370 TABLE OF CONTENTS PETITIONER’S LIST OF EXHIBITS .........................................................................iii I. MANDATORY NOTICES, STANDING, AND FEES .......................... 1 II. OVERVIEW OF CHALLENGE AND RELIEF REQUESTED ............ 2 A. Patents and Publications Relied Upon ........................................... 2 B. Grounds for Challenge ................................................................... 3 III. Background of the Technology ................................................................ 3 IV. OVERVIEW OF THE ’370 PATENT ..................................................... 6 A. Summary of the Claimed Subject Matter ...................................... 6 B. The ’370 Patent Prosecution History ............................................. 8 V. SUMMARY OF THE PRIOR ART ........................................................ 9 VI. Claim Construction ................................................................................ 11 A. Level of Skill in the Art ............................................................... 12 B. “a data register” ........................................................................... 12 C.
    [Show full text]
  • Micron: NAND Flash Architecture and Specification Trends
    NAND Flash Architecture and Specification Trends Michael Abraham ([email protected]) Applications Engineering Manager Micron Technology, Inc. Santa Clara, CA USA August 2009 1 Abstract As NAND Flash continues to shrink, page sizes, block sizes, and ECC requirements are increasing while data retention, endurance, and performance are decreasing. These changes impact systems including random write performance and more. Learn how to prepare for these changes and counteract some of them through improved block management techniques and system design. This presentation also discusses some of the tradeoff myths – for example, the myth that you can directly trade ECC for endurance Santa Clara, CA USA August 2009 2 NAND Flash: Shrinking Faster Than Moore’s Law 200 100 Logic 80 DRAM on (nm) ii 60 NAND Resolut 40 Micron 32Gb NAND (34nm) 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 Semiconductor International, 1/1/2007 Santa Clara, CA USA August 2009 3 Memory Organization Trends Over time, NAND block size is increasing. • Larger page sizes increase sequential throughput. • More pages per block reduce die size. 4,194,304 1,048,576 262,144 65,536 16,384 4,096 1, 024 256 64 16 Block size (B) Data Bytes per Page Pages per Block Santa Clara, CA USA August 2009 4 Consumer-grade NAND Flash: Endurance and ECC Trends Process shrinks lead to less electrons ppgger floating gate. ECC used to improve data retention and endurance. To adjust for increasing RBERs, ECC is increasing exponentially to achieve equivalent UBERs. For consumer applications, endurance becomes less important as density increases.
    [Show full text]
  • Known Issues Third-Party Hardware and Software
    Known Issues Third-party hardware and software September 2021 This document contains all Third-party Hardware and Software that, when used together with SANsymphony, may cause unexpected behavior or impact accessibility, performance, and function. Known issues that apply to DataCore's own products are in their own release notes which are all available from the DataCore Support website. Also see Minimum Hardware Requirements https://www.datacore.com/products/software-defined-storage/tech/prerequisites/ Qualified Hardware Components http://datacore.custhelp.com/app/answers/detail/a_id/1529 The authority on real-time data Continued from previous page Table of Contents Changes made to this document 4 Broadcom 15 BCM57xxx 15 Intel S4510 and S4610 SATA SSD (only 1.8 TB and 3.84 TB are affected) 4 Emulex 15 Applies to all 4 Oce11102-NX/Oce10102-NX 15 Disclaimer 5 Hewlett Packard 15 Server hardware 6 All Converged Network Adaptors (CNAs) 15 CN1000Q 15 Microsoft Windows (general) 7 NC55* SFP 10 Gigabit Adaptors 16 Windows 2016 update regression 7 NC375x/NC382i/NC52x Gigabit Adaptors 16 Windows 2016/2012/2012 R2/2008 7 ProLiant BL460c (Gen10) server blades 16 Windows 2012/2012 R2 only 8 Windows 2008 R2 only 8 IBM 16 49y4250/49y7950 10GiB Adaptor 16 Cisco 9 49y4250/49y7950 10GiB Adaptor 16 Unified Computing Systems (UCS) 9 Intel 17 Fujitsu 9 x710 Chipset 17 Primergy ServerView Control Service 9 Primergy Server Agent 9 Nvidia Mellanox 18 ConnectX SmartNICs - general 18 Hewlett-Packard 9 ConnextX-5 18 Servers with Windows 2012/2012 R2 9 ConnextX-3
    [Show full text]
  • Onfi Overview
    An Update Jim Cooke NAND Marketing Micron Technology, Inc. Thursday, August 6, 2009 Outline . ONFi Overview . ONFi Provides Speed Enhancements . The Path to Higher Performance Santa Clara, CA USA August 2009 2 Thursday, August 6, 2009 Why ONFi ? . NAND was the only commodity memory with no standard interface . The Open NAND Flash Interface (ONFi) Workgroup was formed in May 2006 to drive standardization for the raw NAND Flash interface . ONFi has been busy… Santa Clara, CA USA August 2009 3 Thursday, August 6, 2009 Why ONFi ? . NAND was the only commodity memory with no standard interface . The Open NAND Flash Interface (ONFi) Workgroup was formed in May 2006 to drive standardization for the raw NAND Flash interface . ONFi has been busy… ONFi 1.0 (Dec ’06) Defined a standard electrical and protocol interface for NAND, including the base command set. Santa Clara, CA USA August 2009 3 Thursday, August 6, 2009 Why ONFi ? . NAND was the only commodity memory with no standard interface . The Open NAND Flash Interface (ONFi) Workgroup was formed in May 2006 to drive standardization for the raw NAND Flash interface . ONFi has been busy… ONFi 1.0 (Dec ’06) (Jul ’07) DefinedBlock a standard Abstracted electrical and protocol NAND interface for NAND,1.0 includingDefined the a managed base command NAND set.solution that utilizes the raw NAND interface. Santa Clara, CA USA August 2009 3 Thursday, August 6, 2009 Why ONFi ? . NAND was the only commodity memory with no standard interface . The Open NAND Flash Interface (ONFi) Workgroup was formed in May 2006 to drive standardization for the raw NAND Flash interface .
    [Show full text]
  • Onfi: Achieving Breakthrough NAND Performance
    ONFi: Achieving Breakthrough NAND Performance Amber Huffman Principal Engineer Intel Corporation Agenda ONFi Workgroup Update – Mission and membership – ONFi 2.0 specification completed – NAND connector specification completed – JEDEC collaboration established High-speed NAND interface details Extending the high-speed interface 2 Agenda ONFi Workgroup Update – Mission and membership – ONFi 2.0 specification completed – NAND connector specification completed – JEDEC collaboration established High-speed NAND interface details Extending the high-speed Interface 3 Mission… Possible. NAND has been the only commodity memory with no standard interface – Command set, timings, and pin-out are similar among vendors NAND has been ripe for standardization due to a few inflection points: – 1) Explosion in use of NAND for MP3 players, phones, caches, and SSDs – 2) Increase in number of NAND vendors serving the market (2 to 6+) ONFi Workgroup was formed in May 2006 to address “gap” – ONFI = Open NAND Flash Interface ONFi revision 1.0 delivered in December 2006, defines: – Uniform NAND electrical and protocol interface • Raw NAND component interface for embedded use • Includes timings, electrical, protocol • Standardized base command set – Uniform mechanism for device to report its capabilities to the host ONFI 1.0 sets a solid foundation for NAND (r)evolution. 4 A-Data Afa Technologies Alcor Micro Aleph One Anobit Tech. Apacer Arasan Chip Systems ASMedia Technology ATI Avid Electronics BitMicro Biwin Technology Chipsbank Cypress DataFab Systems DataIO Datalight Denali Software Entorian FCI FormFactor Foxconn Fusion Media Tech Genesys Logic Hagiwara Sys-Com HiperSem Hitachi GST Hyperstone InCOMM Indilinx Inphi Intelliprop ITE Tech Jinvani Systech Kingston Technology Lauron Technologies Lotes LSI Macronix Marvell Mentor Graphics Metaram Members Moai Electronics Molex NVidia Orient Semiconductor P.A.
    [Show full text]
  • Pcie Round Table
    SNIA SSSI - PCIe Round Table • Standards • Technology / Architecture • Deployment Strategies Presentations by: Fusion-io - Intel - Micron - Sata-IO - Seagate - Tailwind SNIA Winter Symposium SSSI Face to Face Monday 23 January 2012 Webex: https//snia.webex.com 10:00 AM - 1:00 PM Meeting No. 795 947 658 Password: sssi2012 St. Claire Hotel, San Jose CA Telecon: 1-877-270-2716 ID: 0021 Password: 8520 Agenda 1. 10:15 AM - 10:30 AM Introduction - SSS Performance Eden Kim, Chair SNIA SSS TWG 2. 10:30 AM - 10:45 AM PCIe SSD Form Factor Mark Meyers, Intel 3. 10:45 AM - 11:00 AM Standards & Deployment Models Marty Czekalski, Seagate 4. 11:00 AM - 11:15 AM SATA-IO & SATA Express - PCIe for Client Storage Paul Wassenberg, Sata-IO 5. 11:30 AM - 11:45 AM PCIe 2.5” Form Factor Janene Ellefson, Micron 6. 11:45 AM - 12:00 PM Convergence of Memory & Storage IO Architecture Moon Kim, Tailwind 7. 12:15 PM - 12:30 PM Lessons from the Front Lines & Lessons for the Future Gary Orenstein, Fusion-io 8. 12:30 PM - 1:00 PM Panel Question & Answers / Working Lunch January 2012 2 PCIe Solid State Storage - Higher Performance / Lower Latencies Solid State Storage PCIe . a Round Table What are issues facing Adoption of PCIe Solid State Storage devices? • Standards for PCIe Attached Storage • Technology & Architectural Issues • Mass Storage Ecosystem Adoption & Optimization • Market & Product Positioning • Deployment Strategies January 2012 3 SNIA PTS-C & PTS-E Specifications: Standardizing SSD Performance Test SNIA SSSI Solid State Performance Test Spec link: www.snia.org/tech_activities/standards/curr_standards/pts
    [Show full text]
  • St D D E Bli Standards Enabling Enterprise Class Ssds P
    Stan dar ds Ena bling Enterprise Class SSDs Amber Huffman Principal Engineer MEMS001 Agenda • Enterprise NVMHCI • ONFi 3.0 • Summary 2 PCI Express* Technology SSD Trend • PCI Express (PCIe) Technology SSDs are happening – Plentiful PCIe lanes – Enables > 600 MB/s in one device – Lower latency (µsec matter) – Opportunity to minimize infrastructure cost wihdiith direct attac h Enterprise SSD Outlook by Interface Pieces K Source: Preliminary Gartner estimates, 12/09 3 Adoption Challenge • The PCI Express* (PCIe) Technology SSDs that are emerging do not have a standard host controller interface (i.e., register i/f) – This requires each vendor to provide a driver with the SSD • Lack of standard drivers is a challenge to PCIe SSD adoption – Requires each SSD vendor to provide a driver for each OS – Requires OEMs to validate each SSD with its own driver, increasing validation time and cost – Makes adoption of PCIe SSDs more difficult • To resolve this, industry leaders are defining Enterprise NVMHCI – Standard host controller interface (register programming interface) for Enterprise class PCIe SSDs – Addresses Enterprise server scenarios with a streamlined and efficient interface enabling very high IOPs 4 Industry Leaders Driving Enterprise NVMHCI The Workgroup includes 50+ member companies, contitiinuing to grow. 5 The Value of Enterprise NVMHCI “A standardized interface functions as a foundation, enabling a volume market for technology innovation while avoiding the compatibility issues that arise from multiple, proprietary interfaces. Enterprise customers are requesting standard interfaces be used on non-volatile-memory products as an enabler to assist broad adoption.” John Loveall Manager of Program Management, Storage and File Systems Microsoft 6 The Value of Enterprise NVMHCI “A standardized interface functions as a foundation, enabling a volume market for technology innovation while avoiding the compatibility issues that arise from multiple, proprietary interfaces.
    [Show full text]
  • 2016 Annual Report and Form 10-K
    Corporate Headquarters Stock Exchange Listing Delivering the possibilities of data Western Digital Corporation Western Digital’s common stock trades 3355 Michelson Drive, Suite 100 on The NASDAQ Global Select MarketSM Irvine, California 92612 under the symbol WDC. 949.672.7000 Investor Relations Worldwide Websites investor.wdc.com westerndigital.com [email protected] investor.wdc.com 800.695.6399 hgst.com sandisk.com wd.com Transfer Agent and Registrar Independent Registered Public American Stock Transfer & Trust Company, LLC Accounting Firm Operations Center - 6201 15th Avenue KPMG LLP 2016 Annual Report Brooklyn, New York 11219 amstock.com 800.937.5449 and Form 10-K Financial and investor information is available on the company’s Investor Relations website at investor.wdc.com. Forward-Looking Statements This Annual Report contains forward-looking statements, including but not limited to, statements relating to the expectations regarding: the growth of digital data and demand for digital storage; the anticipated benefits of Western Digital’s acquisition of SanDisk Corporation and of the integration of the HGST, SanDisk and WD businesses; Western Digital’s positioning and opportunities in the storage industry; Western Digital’s investments in and development of new technologies; and Western Digital’s goal to pay down debt, attain investment grade status and continue paying dividends. These forward-looking statements are based on Western Digital’s current expectations and are subject to risks and uncertainties that could cause actual results
    [Show full text]
  • Western Digital Corporation (Exact Name of Registrant As Specified in Its Charter)
    UNITED STATES SECURITIES AND EXCHANGE COMMISSION WASHINGTON, D.C. 20549 FORM 8-K CURRENT REPORT Pursuant to Section 13 or 15(d) of the Securities Exchange Act of 1934 Date of Report (Date of earliest event reported): October 17, 2013 Western Digital Corporation (Exact Name of Registrant as Specified in its Charter) Delaware 001-08703 33-0956711 (State or Other Jurisdiction of (Commission (I.R.S. Employer Incorporation or Organization) File Number) Identification No.) 3355 Michelson Drive, Suite 100 Irvine, California 92612 (Address of Principal Executive Offices) (Zip Code) (949) 672-7000 (Registrant’s Telephone Number, Including Area Code) Not applicable (Former name or former address, if changed since last report.) Check the appropriate box below if the Form 8-K filing is intended to simultaneously satisfy the filing obligation of the registrant under any of the following provisions: ¨ Written communications pursuant to Rule 425 under the Securities Act (17 CFR 240.425) ¨ Soliciting material pursuant to Rule 14a-12 under the Exchange Act (17 CFR 240.14a-12) ¨ Pre-commencement communications pursuant to Rule 14d-2(b) under the Exchange Act (17 CFR 240.14d-2(b)) ¨ Pre-commencement communications pursuant to Rule 13e-4(c) under the Exchange Act (17 CFR 240.13e-4(c)) Item 7.01 Regulation FD Disclosure. On October 17, 2013, Western Digital Corporation, a Delaware corporation (the “Company”), the parent company of HGST, Inc. (“HGST”), issued a press release announcing that HGST completed its acquisition of Virident Systems, Inc., a Delaware corporation. A copy of the press release is furnished herewith as Exhibit 99.1 and is incorporated herein by reference.
    [Show full text]