Firestop™ CONDUIT and EMT SYSTEMS

Total Page:16

File Type:pdf, Size:1020Kb

Firestop™ CONDUIT and EMT SYSTEMS FireStop™ CONDUIT AND EMT SYSTEMS UL SYSTEM NO. C-AJ-1509 F Rating – 3 hr., T Rating – 0 hr. 1 3b 1. &LOORORWALLASSEMBLY – Minimum 41/2 in. thick reinforced normal weight concrete. Wall may also be constructed of any UL Classified concrete blocks. Maximum diameter of opening is 8 in. See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 3a 2. Through Penetrant – One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop system. Pipe, conduit or tubing to be rigidly supported on both sides of floor or wall assembly. A maximum of one pipe, conduit or tubing 2 to be installed within the opening. The space between the pipe, conduit or tubing and the periphery of opening shall be a minimum of 0 in. to a maximum of 2 in. The following types and sizes of metallic pipes, conduits or tubing may be used: a) Steel pipe – Nom. 24 in. diameter (or smaller) Schedule 10 (or heavier) steel pipe 3a b) Conduit – Nom. 6 in. diameter (or smaller) electrical metallic tubing or steel conduit c) Copper tubing – Nom. 6 in. diameter (or smaller) Type L (or heavier) copper tubing d) Copper pipe – Nom. 6 in. diameter (or smaller) Regular (or heavier) copper pipe. 3b 3. Firestop System – The firestop system shall consist of the following: a) Packing material – NSi FireStop Mineral Wool. Minimum 4 in. thickness of minimum 4 pcf mineral wool batt insulation firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor or from both surfaces of wall as required 2 to accommodate the required thickness of fill material b) Fill, void or cavity material – NSi FireStop Intumescent Caulk. Minimum 1/4 in. thickness of fill material applied within the annulus, flush with top surface of floor or with both surfaces of wall. At the point contact location between through penetrant and concrete, a minimum 1/4 in. diameter bead of fill material shall be applied at the concrete/through penetrant interface on the top surface of floor and on both surfaces of wall. UL SYSTEM NO. C-AJ-1510 F Rating – 2 hr., T Rating – 0 hr. 1 4b 2 1. &LOORORWALLASSEMBLY – Minimum 21/2 in. thick reinforced lightweight or normal weight (100-150 pcf) structural concrete. Floor may also be constructed of any minimum 6 in. thick UL Classified hollow-core precast concrete units. Wall may also be constructed of any UL Classified concrete blocks. Maximum diameter of opening is 261/4 in. Maximum diameter of opening in floors constructed of hollow-core is 7 in. See Concrete Blocks (CAZT) or Precast Concrete Units (CFTV) category in the Fire Resistance Directory for names of 4a manufacturers. 3 2. Steel Sleeve (optional) – Nom. 26 in. diameter (or smaller) Schedule 10 (or heavier) steel pipe cast or grouted into floor or wall assembly, flush with floor or wall surfaces. 4a 3. Through Penetrant – One metallic pipe, conduit or tubing, rigidly supported on both sides of floor or wall assembly. The annular space between the pipe or conduit and the periphery of opening shall be a minimum of 0 in. (point contact) to a maximum of 21/4 in. The following types and sizes of metallic pipes, conduits or tubing may be used: 4b a) Copper tubing – Nom. 6 in. diameter (or smaller) Type L (or heavier) copper tube b) Steel pipe – Nom. 24 in. diameter (or smaller) Schedule 10 (or heavier) steel pipe c) Conduit – Nom. 6 in. diameter (or smaller) steel electrical metallic tubing (EMT) d) Iron pipe – Nom. 24 in. diameter (or smaller) cast or ductile iron pipe. 3 4. Firestop System – The firestop system shall consist of the following: a) Packing material – NSi FireStop Mineral Wool. Minimum 4.5 pcf mineral wool batt insulation, tightly compressed and firmly packed into opening as a permanent form to a minimum depth of 21/4 in. Packing material to be recessed from top surface of floor or from both surfaces of wall as required to accommodate the required thickness of sealant b) Fill, void or cavity material – NSi FireStop Intumescent Caulk. Minimum 1/4 in. thickness of caulk applied within the annulus, flush with top surface of floor or with both surfaces of wall. In floors constructed of hollow-core precast concrete units, fill material installed symmetrically on both sides of floor. Additional material installed to form a minimum 1/4 in. crown bead at the point contact location between the pipe and periphery of the opening. For vertical installations, sealant to be applied symmetrically on both sides of wall. 211 NSi NSiMASTER.indd 211 12/4/09 11:01:52 AM FireStop™ CONDUIT AND EMT SYSTEMS UL SYSTEM NO. C-AJ-1511 F Rating – 2 hr., T Rating – 0 hr. 1 3 1. &LOORORWALLASSEMBLY – Minimum 21/2 in. thick reinforced lightweight or normal weight (100-150 pcf) concrete floor. Floor may also be constructed of any minimum 6 in. thick UL Classified hollow-core precast concrete units. Wall may also be constructed of any UL Classified concrete blocks. Maximum diameter of opening is 24 7/8 in. Maximum diameter of opening in floors constructed of hollow-core is 7 in. See Concrete Blocks (CAZT) or Precast Concrete Units (CFTV) category in the Fire Resistance Directory for names of manufacturers. 2. Through Penetrant – One metallic pipe, conduit or tubing to be installed within the firestop system. Pipe, conduit or tubing to be 2 rigidly supported on both sides of floor or wall assembly. The annular space between the pipe or conduit and the periphery of opening shall be a minimum of 0 in. (point contact) to a maximum of 7/8 in. The following types and sizes of metallic pipes, conduits or tubing may be used: 3 a) Steel pipe – Nom. 24 in. diameter (or smaller) Schedule 10 (or heavier) steel pipe b) Iron pipe – Nom. 24 in. diameter (or smaller) cast or ductile iron pipe c) Conduit – Nom. 6 in. diameter (or smaller) steel electrical metallic tubing or steel conduit d) Copper pipe or tubing – Nom. 6 in. diameter (or smaller) Type L (or heavier) copper tubing. 3. Fill, void or cavity material – NSi FireStop Intumescent Caulk. Minimum 1/2 in. thickness of caulk applied within the annulus, flush with top surface of floor or with both surfaces of wall. In floors constructed of hollow-core precast concrete units, fill material installed 2 symmetrically on both sides of floor. Additional material installed to form a minimum 1/4 in. crown bead at the point contact location between the pipe and periphery of the opening. For vertical installations, sealant to be applied symmetrically on both sides of wall. UL SYSTEM NO. W-L-1349 F Rating – 2 hr., T Rating – 0 hr. 1a 1. 7ALL!SSEMBLY – The fire-rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner described in the individual U300 or U400 Series Wall or Partition Design in the UL Fire Resistance Directory and shall include the following 3 construction features: a) Studs – Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom. 2 x 4 in. lumber spaced 16 in. oc. Steel studs to be minimum 3 5/8 in. wide and spaced maximum 24 in. oc. When steel studs are used and the diameter of openings exceeds the width of stud cavity, the opening shall be framed on all sides using lengths of steel stud installed between vertical studs and screw-attached to the studs at each end. The framed opening in the wall shall be 4 to 6 in. wider and 4 to 6 1b 2 in. higher than the diameter of the penetrating item such that, when the penetrating item is installed in the opening, a 2 to 3 in. clearance is present between the penetrating item and the framing on all four sides. b) Wallboard, Gypsum – 5/8 in. thick, 4 ft. wide with square or tapered edges. The gypsum wall board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Maximum diameter of opening is 6 5/8 in. 2. Through Penetrant – One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop 3 system. The annular space between pipes, conduits or tubing and the periphery of opening shall be a minimum of 0 in. (point contact) to a maximum of 1/2 in. Pipe, tubing or conduit to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, tubing or conduits may be used: 2 a) Steel pipe – Nom. 24 in. diameter (or smaller) Schedule 5 (or heavier) steel pipe b) Iron pipe – Nom. 24 in. diameter (or smaller) cast or ductile iron pipe c) Conduit – Nom. 6 in. diameter (or smaller) steel electrical metallic tubing or steel conduit d) Copper Tubing – Nom. 6 in. diameter (or smaller) Type L (or heavier) copper tubing e) Copper Pipe – Nom. 6 in. diameter (or smaller) Regular (or heavier) copper pipe. 3. Fill, void or cavity material – Sealant – NSi FireStop Intumescent Caulk. Minimum 11/4 in. thickness of fill material applied within the annulus, flush with both surfaces of wall. At the point contact location between through penetrant and gypsum wall board, a minimum 1/2 in. diameter bead of fill material shall be applied at the gypsum wallboard/through penetrant interface on both surfaces of wall.
Recommended publications
  • Section 230517
    NORTHWESTERN UNIVERSITY PROJECT NAME ____________ FOR: ___________ JOB # ________ ISSUED: 03/29/2017 SECTION 23 0517 - SLEEVES AND SLEEVE SEALS FOR HVAC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Sleeves. 2. Sleeve-seal systems. 3. Sleeve-seal fittings. 4. Grout. 1.3 ACTION SUBMITTALS A. Product Data: For each type of product indicated. PART 2 - PRODUCTS 2.1 SLEEVES A. Cast-Iron Wall Pipes: Cast or fabricated of cast or ductile iron and equivalent to ductile-iron pressure pipe, with plain ends and integral waterstop unless otherwise indicated. B. Galvanized-Steel Wall Pipes: ASTM A 53/A 53M, Schedule 40, with plain ends and welded steel collar; zinc coated. C. Galvanized-Steel-Pipe Sleeves: ASTM A 53/A 53M, Type E, Grade B, Schedule 40, zinc coated, with plain ends. D. Galvanized-Steel-Sheet Sleeves: 0.0239-inch (0.6-mm) minimum thickness; round tube closed with welded longitudinal joint. E. Molded-PE or -PP Sleeves: Removable, tapered-cup shaped, and smooth outer surface with nailing flange for attaching to wooden forms. 2.2 SLEEVE-SEAL SYSTEMS A. Manufacturers: Subject to compliance with requirements, provide products by one of the following: SLEEVES AND SLEEVE SEALS FOR HVAC PIPING 23 0517 - 1 NORTHWESTERN UNIVERSITY PROJECT NAME ____________ FOR: ___________ JOB # ________ ISSUED: 03/29/2017 1. Advance Products & Systems, Inc. 2. CALPICO, Inc. 3. Metraflex Company (The). 4. Pipeline Seal and Insulator, Inc.
    [Show full text]
  • Guideline on Through Penetration Firestopping
    GUIDELINE ON THROUGH-PENETRATION FIRESTOPPING SECOND EDITION – AUGUST 2007 SHEET METAL AND AIR CONDITIONING CONTRACTORS’ NATIONAL ASSOCIATION, INC. 4201 Lafayette Center Drive Chantilly, VA 20151-1209 www.smacna.org GUIDELINE ON THROUGH-PENETRATION FIRESTOPPING Copyright © SMACNA 2007 All Rights Reserved by SHEET METAL AND AIR CONDITIONING CONTRACTORS’ NATIONAL ASSOCIATION, INC. 4201 Lafayette Center Drive Chantilly, VA 20151-1209 Printed in the U.S.A. FIRST EDITION – NOVEMBER 1996 SECOND EDITION – AUGUST 2007 Except as allowed in the Notice to Users and in certain licensing contracts, no part of this book may be reproduced, stored in a retrievable system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of the publisher. FOREWORD This technical guide was prepared in response to increasing concerns over the requirements for through-penetration firestopping as mandated by codes, specified by system designers, and required by code officials and/or other authorities having jurisdiction. The language in the model codes, the definitions used, and the expectations of local code authorities varies widely among the model codes and has caused confusion in the building construction industry. Contractors are often forced to bear the brunt of inadequate or confusing specifications, misunderstandings of code requirements, and lack of adequate plan review prior to construction. This guide contains descriptions, illustrations, definitions, recommendations on industry practices, designations of responsibility, references to other documents and guidance on plan and specification requirements. It is intended to be a generic educational tool for use by all parties to the construction process. Firestopping Guideline • Second Edition iii FIRE AND SMOKE CONTROL COMMITTEE Phillip E.
    [Show full text]
  • PLUMBING DICTIONARY Sixth Edition
    as to produce smooth threads. 2. An oil or oily preparation used as a cutting fluid espe cially a water-soluble oil (such as a mineral oil containing- a fatty oil) Cut Grooving (cut groov-ing) the process of machining away material, providing a groove into a pipe to allow for a mechani cal coupling to be installed.This process was invented by Victau - lic Corp. in 1925. Cut Grooving is designed for stanard weight- ceives or heavier wall thickness pipe. tetrafluoroethylene (tet-ra-- theseveral lower variouslyterminal, whichshaped re or decalescensecryolite (de-ca-les-cen- ming and flood consisting(cry-o-lite) of sodium-alumi earthfluo-ro-eth-yl-ene) by alternately dam a colorless, thegrooved vapors tools. from 4. anonpressure tool used by se) a decrease in temperaturea mineral nonflammable gas used in mak- metalworkers to shape material thatnum occurs fluoride. while Usedheating for soldermet- ing a stream. See STANK. or the pressure sterilizers, and - spannering heat resistantwrench and(span-ner acid re - conductsto a desired the form vapors. 5. a tooldirectly used al ingthrough copper a rangeand inalloys which when a mixed with phosphoric acid.- wrench)sistant plastics 1. one ofsuch various as teflon. tools to setthe theouter teeth air. of Sometimesaatmosphere circular or exhaust vent. See change in a structure occurs. Also used for soldering alumi forAbbr. tightening, T.F.E. or loosening,chiefly Brit.: orcalled band vapor, saw. steam,6. a tool used to degree of hazard (de-gree stench trap (stench trap) num bronze when mixed with nutsthermal and bolts.expansion 2. (water) straightenLOCAL VENT.
    [Show full text]
  • Drywall Fastener Systems
    FASTENERS FOR EXTERNAL THERMAL FASTENERS FOR FLAT ROOF FRAME AND GENERAL SELFDRILLING SCREWS FOR LIGHTWEIGHT INSULATION SYSTEM THERMAL INSULATION PURPOSE FASTENERS WALL AND ROOF CLADDING AND WATERPROOFING SYSTEM 2016 POLISH POLISH POLISH POLISH PRODUCER PRODUCER PRODUCER PRODUCER SCREWS AND FASTENERS SCREWS AND FASTENERS CHEMICAL FOR WOODEN STRUCTURES FOR WINDOWS AND DOORS ANCHORING SYSTEMS 2016 DRYWALL FASTENER SYSTEMS POLISH POLISH PRODUCER PRODUCER +48 34 326 1300 +48 34 326 1300 2017 +48 34 326 13 00 www.wkret-met.com Production plant no. 1 - area of 20.000 square meters The largest manufacturer of fastening systems in Poland Klimas Wkręt-Met is the largest manufacturer Klimas Wkręt-Met sends its products to over The area intended for new investments of high quality fastening systems in Poland 60 countries. The company started its opera- covers as much as 100.000 square meters. and Eastern and Central Europe. For years, tions in 1990. It was developed as a contin- the company has set standards in fastening uation of a family-run business dealing in Wkręt-Met was the fi rst company in Poland technology. Our off er includes screws for in- production of plastic elements. to have been granted a European Technical stallation in PVC; window and door fi xings; Initially, it was a site of 300 square meters Approval for building products in 2005 and frame and expansion anchors; fasteners for with several production machines and lim- today the company holds 20 such approvals. thermal insulation systems being an im- ited storage facilities. Much has changes Our other products have national technical portant element of passive houses; hard- since that time.
    [Show full text]
  • Firestopping Application Guide
    Firestopping Application Guide www.grabberman.com VERSION 4.0 NOTES Table of Contents Page Table of Contents Table Table of Contents .........................................................................................................................................................................................i General Certificate of Conformance ...............................................................................................................................................................iii LEEDS Information United States LEEDs .....................................................................................................................................................................v Canadian LEEDs .........................................................................................................................................................................vii Product Data Sheets GrabberGard EFC .........................................................................................................................................................................ix GrabberGard IFC ........................................................................................................................................................................ xiii GrabberGard EFS .......................................................................................................................................................................xvii Material Data Sheets GrabberGard EFC ........................................................................................................................................................................xxi
    [Show full text]
  • Pipe Sleeves, Supports, and Anchors for Facility Services
    SECTION 20 20 13 PIPE SLEEVES, SUPPORTS, AND ANCHORS FOR FACILITY SERVICES PART 1 - GENERAL 1.01 SECTION INCLUDES A. Pipe sleeve B. Pipe hangers, supports, and guides C. Anchors and anchorage devices D. Seismic requirements 1.02 RELATED SECTIONS A. Miscellaneous metalwork is specified in Section 05 50 00 - Metal Fabrications. Coordinate the work of this Section with Section 05 50 00 - Metal Fabrications, for steel materials, fabrication, galvanizing, and painting. B. Basic mechanical materials and methods are specified in Section 20 10 13 - Common Materials and Methods for Facility Services – Fire Suppression, Plumbing and HVAC. C. Vibration isolation and seismic restraint devices are specified in Section 20 30 13 - Vibration Isolation and Seismic Control for Facility Services. Coordinate the work of this Section with the work of Section 20 30 13 - Vibration Isolation and Seismic Control for Facility Services. 1.03 MEASUREMENT AND PAYMENT A. Separate measurement or payment will not be made for the work required under this Section. All costs in connection with the Work specified herein will be considered to be included or incidental to the Work of this Contract. 1.04 REFERENCES A. American Society of Mechanical Engineers (ASME): 1. ASME B31.1 Power Piping 2. ASME B31.2 Fuel Gas Piping 3. ASME B31.9 Building Service Piping Code 4. ASME B36.10 Welded and Seamless Wrought Steel Pipe B. American Society for Testing and Materials (ASTM): 1. ASTM A36/ Specification for Carbon Structural Steel A36M RELEASE – R2.0 SECTION 20 20 13 BART FACILITIES STANDARDS ISSUED: 9/30/2008 PAGE 1 OF 12 STANDARD SPECIFICATIONS PIPE SLEEVES, SUPPORTS, AND ANCHORS FOR FACILITY SERVICES 2.
    [Show full text]
  • Marine RISE Cable Catalog
    RISE® SEALING SYSTEM FOR MULTI-CABLE TRANSITS TESTED TO IMO RESOLUTION A.754(18); FIRE CLASS A0-A60 and H0-H120 EC (MED) CERTIFICATE 09156/CO ISSUED BY BUREAU VERITAS WE CARE CONTENTS page 1 Introduction to BEELE Engineering pages 2-3 Performance of RISE® rubber grade and sealing system pages 4-5 RISE® tables and possible configurations pages 6-17 RISE® installation instructions pages 18-23 RISE® EXTEND-A-FRAMES for existing block systems pages 24-25 RISE® properties and additional testing pages 26-31 RISE® EMC/EMI penetrations: installation instructions pages 32-35 RIACNOF® and NOFIRNO® multi-cable transits pages 36 Calculation software page 37 BEELE R&D - special applications Copyright : BEELE Engineering BV/CSD International BV, Aalten, the Netherlands. Proprietary rights on all drawings and technical data released in this brochure. © 1997-2018 Edition : NWS 2018 Note : No part of this publication may be reproduced without explicit written approval of BEELE Engineering BV. Research & Development : BEELE Engineering BV, Aalten, the Netherlands. Note : The manufacturer reserves the right to make dimensional and design modifications without prior notification. ® : ACTIFIRE, ACTIFOAM, AQUASTOP, BEEBLOCK, BEELE, BEESEAL, CONDUCTON, CRUSHER, CSD, CSD THE SIMPLE SEAL SYSTEM, DRIFIL, DYNATITE, FIRSTO, FIWA, LEAXEAL, MULTI-ALL-MIX, NOFIRNO, RAPID TRANSIT SYSTEM, RIACNOF, RISE, RISWAT, S, SLIPSIL, flanges SLIPSIL plugs, ULEPSI and YFESTOS are registered trade marks of BEELE Engineering BV. brochure code : rise cable/hb/en/mar WE CARE BEELE ENGINEERING - SAFETY, RELIABILITY, INVOLVEMENT Every moment of the day, in every business and every situation, the threat of fire is present. For over three decades, BEELE Engi- neering has specialized in passive fire safety in the form of systems which prevent the spread of fire, smoke, water and gases via cable and pipe penetrations.
    [Show full text]
  • Fire Stop Systems
    Fire-rated sealants for floor and wall through-penetrations Fire Stop Systems While electrical, plumbing and mechanical systems are a necessity in building construction, it is often necessary to pass these systems through hourly fire-resistive floor or wall assemblies. Typically, openings are cut or drilled through the floor or wall, and then the penetrating items are installed. However, this leaves an opening, or annular space, through which fire can spread. Firestop materials are installed within the openings and around the penetrants to prevent the passage of flames and hot gases through an otherwise fire-resistive assembly. Fire Spread Prevention User’s Guide This brochure explains: – Where fire stop systems are used – The three types of fire stop systems that USG offers – How to select and specify the appropriate fire stop system Pages Understand Your System 4 Overview Applications Components Performance Testing Select Your System 11 Performance Selector Penetration Fire Tests Construction Joint Fire Tests Fire Containment Curtain Wall Systems Design Your System 39 Good Design Practices Specify Your System 40 Application Guide Specifications For More Information Technical Service 800 USG.4YOU Web Site www.usg.com 3 USG Fire Stop Systems Overview The intersection where two fire-rated assemblies meet (for example, a wall assembly and a floor/ceiling assembly) also creates a joint through which fire can spread. To prevent this, fire-rated construction joint assemblies are installed at these intersections. USG Fire Stop Systems address this problem of openings in the barrier. They consist of mortar-, caulk- and intumescent-type materials that provide reliable firestops. Mortar-type Materials These materials are applied wet over the forming materials (where applicable).
    [Show full text]
  • Through-Penetration Firestop Systems UL System No. C-AJ-1557 F Ratings - 2 and 3 Hr (See Item 3) T Rating - 0 Hr
    Through-penetration Firestop Systems UL System No. C-AJ-1557 F Ratings - 2 and 3 Hr (See Item 3) T Rating - 0 Hr 1 3B 2 3B A A 1A 3A SECTION A-A CONFIGURATION A 3B 3B 3B 1 A A 2 3A SECTION A-A CONFIGURATION B Page 1 of 5 UL System C-AJ-1557 continued… 1 3B 2 3A A A 1A 3B SECTION A-A CONFIGURATION C 3B 3B 3B 1 A A 3A 2 SECTION A-A CONFIGURATION D 1. Floor or Wall Assembly - Min. 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf (1600-2400 kg/m3)) concrete floor or min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight concrete wall. The min. thickness of the wall is dependent upon the firestop configuration as shown in Item 3. Wall may also be constructed of any UL Classified Concrete Blocks*. Floor may also be constructed of any min. 6 in. (152 mm) thick UL Classified hollow-core Precast Concrete Units*. If the firestop system is installed within a hollow-core precast concrete unit, max. dia. of opening shall be 7 in. (203 mm). Otherwise, max. dia. of opening is 15-1/4 in. (391 mm). See Concrete Blocks (CAZT) and Precast Concrete Units (CFTV) categories in the Fire Resistance Directory for names of manufacturers. 1A. Metallic Sleeve - (Optional) -Nom. 14 in. (356 mm) dia. (or smaller) Schedule 10 (or heavier) steel sleeve cast or grouted into floor or wall assembly, flush with floor or wall surfaces.
    [Show full text]
  • Understanding and Applying Code Requirements for Firestopping
    Understanding and Applying Code Requirements for Firestopping Ted Colwell 3M Tim Mattox, Sr. Specified Technologies Inc. International Firestop Council -PRESENTATION CODE OF ETHICS- The Representative, when speaking about firestopping technology and using language, information, presentations, logos, or any other communication means that could be reasonably likely to cause the recipient(s) of such information to believe that the communication represents an official IFC technical viewpoint, shall: • Hold themselves out to the public with professionalism and sound ethics by conducting themselves in a way that reflects positively on IFC and the IFC members • Clearly state their affiliation • Identify their relationship with IFC • Declare that they are presenting an official (unmodified) presentation prepared by IFC • Indicate whether the presentation is at the official request of IFC • This presentation will not highlight, focus or reference to a specific product of manufacturer 2 Seminar agenda • What is firestopping, and why is it required? • Code Requirements - overview • Penetration Firestop Systems • Membrane penetrations • Firestop installation options • Engineering judgments • Special inspection and special inspectors • Plan review and inspection process recommendations • Recognizing firestop installation problems 3 Understanding the Concept of Balanced Fire Protection Balanced Fire Protection • An integrated system of fire and smoke protection elements in the construction environment composed of detection, suppression and containment
    [Show full text]
  • 1847 Sleeves and Sleeve Seals for Fire-Suppression Piping 210517 - 1
    SECTION 210517 - SLEEVES AND SLEEVE SEALS FOR FIRE-SUPPRESSION PIPING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Sleeves. 2. Sleeve-seal systems. 3. Grout. 1.2 ACTION SUBMITTALS A. Product Data: For each type of product indicated. PART 2 - PRODUCTS 2.1 SLEEVES A. Galvanized-Steel-Pipe Sleeves: ASTM A 53/A 53M, Type E, Grade B, Schedule 40, zinc coated, with plain ends. B. Galvanized-Steel-Sheet Sleeves: 0.0239-inch minimum thickness; round tube closed with welded longitudinal joint. 2.2 SLEEVE-SEAL SYSTEMS A. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following: 1. Advance Products & Systems, Inc. 2. CALPICO, Inc. 3. Metraflex Company (The). 4. Pipeline Seal and Insulator, Inc. 5. Proco Products, Inc. B. Description: Modular sealing-element unit, designed for field assembly, for filling annular space between piping and sleeve. 1. Sealing Elements: EPDM-rubber interlocking links shaped to fit surface of pipe. Include type and number required for pipe material and size of pipe. 2. Pressure Plates: Carbon steel. 3. Connecting Bolts and Nuts: Carbon steel, with corrosion-resistant coating, of length required to secure pressure plates to sealing elements. 1847 SLEEVES AND SLEEVE SEALS FOR FIRE-SUPPRESSION PIPING 210517 - 1 2.3 GROUT A. Standard: ASTM C 1107/C 1107M, Grade B, post-hardening and volume-adjusting, dry, hydraulic-cement grout. B. Characteristics: Nonshrink; recommended for interior and exterior applications. C. Design Mix: 5000-psi, 28-day compressive strength. D. Packaging: Premixed and factory packaged.
    [Show full text]
  • Stifirestop.Com PRODUCT SELECTOR
    FIRESTOPPING Products for Life Safety and Code Compliance www.stifirestop.com PRODUCT SELECTOR SPECIFIED TECHNOLOGIES INC. Specified Technologies Inc. (STI) is an industry leader solely committed to the development of innovative, reliable firestopping solutions that help stop the spread of fire, smoke and toxic fumes. For over 25 years, our management team has worked hand in hand with the construction industry to create innovative firestop solutions for all types of new construction and retrofit applications. ® We offer the broadest range of UL ©2009 Specified Technologies, Inc. Classified Systems — more than any other manufacturer. We keep material FIRESTOP SEALANTS requirements to a minimum and we design Triple S® Intumescent Sealant — Pg. 4 systems with the installer in mind. The Premium grade intumescent firestop sealant featuring STI’s patented result is less labor and significantly lower two-stage intumescent technology. Triple S can be used in most installed costs. common through-penetrations as well as a variety of membrane A penetrations and construction joints. LCI Intumescent Sealant — Pg. 4 Standard grade intumescent firestop sealant engineered to economically address many common through-penetration applications in light commercial construction. LC Endothermic Sealant — Pg. 5 High quality, non-halogenated firestopping sealant designed for non-combustible penetrants in through-penetrations and construction joints. PENSIL® Silicone Products — Pg. 7 A 100% silicone firestop caulk engineered to rapidly cure and resist washout (W Ratings) when used in exposed applications. Also used in construction joint applications. RESIDENTIAL CAULK WF300 Firestop Caulk — Pg. 5 Intumescent firestop caulk designed for sealing through-penetrations and gaps in fire resistance-rated wood frame construction.
    [Show full text]