FCI ST100 Series Thermal Mass Flow Meters Advanced Solutions for Process and Plant Gas Flow Metering Mass Flow, Temperature and Pressure FCI ST100 SERIES

Chemical Wastewater Treatment, Landfills Refineries Oil & Gas Mining Metals Manufacturing Cement, Stone, Brick, Glass Power Utilities Pulp & Paper Food & Beverage And more... ST100 Series Features

g Direct gas mass flow measuring

g Flow rate, total flow, temperature, pressure measurement

g No moving parts, lowest maintenance

g Most extensive and comprehensive global approvals for Ex installations Model ST100 g Temperature service to 850 °F [454 °C] with -FP style flow element g Rugged, industrial transmitter enclosure Model ST100 readout g Graphic, multivariable LCD readout

g Integral and remote versions

g Multi-gas calibrations

g Multiple analog outputs ­– 4-20 mA, pulse

g HART®, Foundation™ Fieldbus, PROFIBUS PA, Modbus RS-485

g Dual-element systems Model ST100L in-line g ™ flow meter Patented VeriCal In-Situ Calibration Verification System

g SIL compliant

g On-board data logger

g configurations to optimize application performance

g Extensive selection of process connections

ST100 Series – The Future of Gas Flow Metering

With FCI’s new ST100 Series, the science of process gas flow or upgrade, ST100 can be converted to any of these outputs with metering has never been so advanced or so future-ready! a card change, in the field. That takes “never obsolete” to a whole ST100 is an all-new thermal dispersion technology gas flow meter new level. that combines feature- and function-rich electronics with the industry’s Then there’s ST100’s display/readout which brings new meaning most advanced flow to achieve a truly state-of-the-science to the term “process information.” Simply, the ST100’s graphical flow metering solution for industrial processes and plant applications. display provides the most comprehensive information on process The ST100 Series transmitter is unsurpassed in meeting measurements and conditions of any thermal flow meter available your current and future need for outputs, process information and (see page 7). communications. Whether your output needs are traditional 4-20 mA In the gas stream, ST100 flow elements and process connections analog, frequency/pulse or advanced digital bus communications ensure the best possible measurements and effective installation. such as HART, Foundation Fieldbus, PROFIBUS or Modbus, ST100 FCI flow element designs have been perfected and optimized through has your solution. What’s more, should you ever need to change six decades of R&D and real world experience in thermal dispersion

2 technology and flow metering applications. With thermal dispersion Find your gas here? there are no moving parts to foul or clog. This results in the greatest reliability and valuable savings on maintenance. FCI has provided thermal mass flow meter solutions Fast response, accuracy, repeatability and long-life are for all of these and more… hallmarks of FCI flow elements available with ST100. And, all new, are the STP models that include pressure measurement. Mass flow, Acetaldehyde Ethyl Acrylate Ketene Phenol Acetic Acid Ethyl Alcohol Krypton Phosgene temperature and pressure in a single tap point thermal dispersion Acetone Ethyl Amine Landfill Gas Propadiene meter — that’s an industry first and FCI exclusive! Acetonitrile Ethyl Benzene M-Cresol Propane Then, consider other ST100 Series exclusives like dual- Acetyl Chloride Ethyl Bromide Mercury Propanol element averaging systems (see page 8) and FCI’s patented Air Ethyl Chloride Methane Propyl Chloride VeriCal option that provides significant cost and time savings by Allyl Chloride Ethyl Fluoride Methanol Propylene performing dynamic wet calibration verification in-situ, without Ammonia Ethyl Mercaptan Methyl Acetate Propylene Oxide Propyne ever removing the instrument from the process (see page 10). To Aniline Ethylene Methyl Alcohol Argon Ethylene Methyl Amine P-Xylene ensure both ease of installation and a match with your process Benzene Dichloride Methyl Butane R-11 conditions, the ST100 Series offers a comprehensive selection of Bio-Gas Ethylene Oxide Methyl Fluoride R-12 process connections and installation options. Boron Trifluoride Flare Gas Methyl Formate R-13 Your smart investment in an ST100 Series flow meter is Bromine Fluorine Methyl Hexane R-13B1 complete with FCI precision calibration. FCI’s NIST traceable flow Bromobenzene Fluorobenzene Methyl Hydrazine R-14 Fluoroform R-21 calibration facility is unmatched by any other thermal dispersion Butadiene Methyl Butene Freon-11 Mercaptan R-22 flow meter manufacturer. Your ST100 Series flow meter is custom Butylene Oxide Freon-12 Methyl Octane R-23 calibrated to exacting process and fluid conditions, essential to Butyne Freon-13 Methyl Pentane R-112 providing the highest precision, longest lasting solution that meets Carbon Dioxide Freon-14 Methylal R-113 its specifications and your specific application. Carbon Disulfide Freon-21 Methylene R-114 Chloride Carbon Monoxide Freon-22 R-114B2 Morpholine Carbon Freon-23 R-115 Tetrachloride Furan M-Xylene R-116 ST100 Series Model Summary Carbonyl Sulfide Halon Naphthalene R-134A Chlorine Helium Natural Gas R-142B ST Series Chlorobenzene Heptene N-Butane R-152A Model ST100 ST100L ST102 ST110 ST112 Chloroethane Hexanol N-Butane R-216 Basic Type Insertion In-Line Insertion Insertion Insertion Chloroform Hexene N-Butanol R-500 Flow a a a a a Chloromethane Hydrazine N-Butyl Alcohol R-502 N-Decane Temperature a a a a a Chloroprene Hydrogen R-503 Cis-2-Butene N-Dodecane R-504 Dual-Element a a Hydrogen Cis-2-Hexene Bromide Neon R-C318 VeriCal In-Situ Neopentane Calibration Verification a a Compressed Air Hydrogen Radon Chloride Cumene N-Heptane Silane STP Series Hydrogen Cyanogen N-Hexane Silicon Model STP100 STP102 STP110 STP112 Cyanide Cyclobutane Nitric Oxide Tetrachloride Hydrogen Basic Type Insertion Insertion Insertion Insertion Nitrogen Styrene Cyclohexane Deuteride Flow Nitrogen Dioxide Sulfur Dioxide a a a a Cyclooctane Hydrogen Temperature a a a a Cyclopentane Fluoride Nitromethane Sulfur Hexafluoride Pressure Cyclopropane Hydrogen Iodide Nitrous Oxide a a a a Sulfur Trioxide Decene Hydrogen N-Nonane Dual-Element a a Superheated Deuterium Peroxide N-Octane VeriCal In-Situ Thiophene a a Hydrogen Sulfide Nonene Calibration Verification Deuterium Oxide Titanium Diethyl Amine Iodine N-Pentane Tetrachloride Diethyl Ether Isobutane N-Propanol Toluene The ST100 Series is comprised of two core families – the “ST” and the Diethyl Ketone Isobutene N-Propyl Alcohol Trans-2-Butene “STP,” with nine total models. The ST family features instruments that Digester Gas Isobutyl Alcohol N-Propyl Amine Trimethyl Amine measure both mass flow and temperature. The STP family is an FCI Dimethyl Ether Isoheptane N-Undecane Triptane exclusive thermal dispersion flow meter that additionally measures a Dimethyl Isohexane Octene Uranium Isooctane third parameter – pressure. Within both families are basic single-point Propane Oxygen Hexafluoride Dimethyl Sulfide Isopentane O-Xylene Vinyl Acetate models, dual-element averaging systems and models with VeriCal, an Ethane Isoprene Ozone Vinyl Chloride FCI patented in-situ calibration verification system. Ethanol Isopropyl Alcohol Pentanol Vinyl Fluoride Ethyl Acetate Isopropyl Amine Pentene Vinyl Formate

3 Inputs, Outputs and Bus Communications Digital Bus Communications Options for Today and Tomorrow The ST100 Series features the most comprehensive selection of ST100 Series’ extensive and comprehensive offering of field- digital bus communications available in a thermal dispersion flow interchangeable outputs is your assurance of compatibility with meter. All bus communications provide actual measurements, your process control system for the long term. Whether your including flow rate, total flow, temperature and, with STP models, network is analog based or bus comm based, there is a compatible pressure. Instrument diagnostics and service information are solution with ST100. And, if your plant has ever considered continuously accessible via the bus. All ST100 Series user set-up changing or upgrading system communications in the future, the and configuration parameters may also be performed over the bus. ST100 Series is ready to change with you. Each of the ST100 output Included with the analog output cards is a two-way HART bus types is modular and completely interchangeable in the field, at any over the #1 4-20 mA output. The HART bus complies with revision time. This assures adaptability and compatibility with your process level 7 protocol and is fully compatible with all versions of HART field measurement and control strategy – today and tomorrow. communicators and HART control systems. Instead of analog outputs / HART, you can select a digital bus of: Foundation Fieldbus H1, PROFIBUS PA or Modbus RS-485. These bus options are full two-way I/O communications. HART, Foundation Fieldbus and PROFIBUS communication options are provided with device interface software, either EDD or DTM type, for easy, seamless integration with process control systems and PC-based frame applications such as PACTware. These software packages and updates can be downloaded from FCI’s website and from the respective bus organization’s websites. FCI obtains registration and certification on its products from the respective bus organizations. *

www.hartcomm.org www.profibus.com www.fieldbus.org www.fdtgroup.org

* ST100 Series with Foundation™ Fieldbus communications is a certified and Analog Outputs with HART registered device with FieldComm Group™. Registered features include alarms and events, function block linking, trending, multi-bit alert reporting and field Comprehensive, scalable and flexible describe the ST100 Series’ diagnostics. The ST100 was one of the first two devices to be compliant and analog outputs bundle. The analog output card features triple certified with advanced field diagnostics. Manufacturer ID (HEX) 01FC49. 4-20 mA outputs that are fully assignable to flow rate and/or ST100 Series with HART® communications is a certified and registered device temperature, and with STP models, pressure. All 4-20 mA outputs with FieldComm Group, registration number L2-06-1000-168. Manufacturer are user scalable to represent the full range or any subset and ID (HEX) 00A6. are fully assignable to any of the measured variables. Outputs are isolated and have fault indication per NAMUR NE43 guidelines, user selectable for high (> 21.0 mA) or low (< 3.6 mA). Digital I/O Ports Additionally, full two-way HART communication is included and available over the #1 4-20 mA output. The analog card also includes All ST100 Series models include a USB port for connection to a laptop a user selectable 0-1 kHz or 0-10 kHz frequency or pulse output of or other computer for all user set-up programming, field enactable flow. The frequency output is proportional to flow rate while the device changes and servicing diagnostics. Also provided standard pulse output can be used for external flow totalizers. is an Ethernet 10/100 network port designed to facilitate remote access by FCI service personnel to perform service and diagnostics. Temporary connection to both USB and Ethernet connections can be made easily by removing the rear cover of the instrument enclosure, or the unit can be permanently attached through the conduit ports.

4 Digital Display / Readout

The ST100 Series’ optional digital readout provides a best-in-class troubleshooting. (In the blind unit, these functions must be performed information suite, backlighted LCD and four (4) optical touch buttons. through the USB port or bus communications.) These buttons are The display backlight has a unique proximity detector that illuminates activated through the front panel glass. There is no need to open it only when a person approaches, or can be set to “always on.” The the enclosure or declassify a hazardous area to perform functions. display and button functions can be rotated electronically, via the An atypical button sequence is required for button activation which buttons, in 90° increments to optimize display viewing and button prevents accidental or unauthorized access to the menus. activations. The display provides readouts of the process variables and The display buttons provide convenient, ready access to all service diagnostics. The normal process measuring mode screen is the instrument set-up and programming, as well as diagnostics and most comprehensive of any thermal dispersion flow meter available.

Backlighted LCD

Instrument fault/service icon 101 segment flow rate bargraph Only appears if fault detected Flow rate Engineering units Flow totalizer Temperature Alarm status indicators Only appear if alarm is tripped Pressure (STP models) Current selected group With multiple calibration groups User programmable 17 character field Show tag, process name or gas type, etc. on display

Four (4) optical touch buttons for programming and display selections — Activated through front panel window; Scroll up Easy to follow sequence no need to open enclosure menu for set-up and selections — Protected from accidental or unwanted activation

Go back/ escape Enter / select

Scroll down

5 Sensors Optimized to Meet the Application Extensive Selection of Process Connections

High quality thermal mass An unmatched selection of process connection choices assures a begins with the sensor element in the flow stream. match for any installation requirements. Only FCI combines six decades of field experience Insertion flow meters – For most applications an adjustable “U” with extensive R&D and performance validation “FPC” Style length (insertion depth) configured with compression fittings offers Element utilizing an on-premise flow laboratory with more the most installation flexibility. Adjustable elements are available in than 18 flow stands. FCI is the leader in thermal 6 inch [152 mm], 12 inch [305 mm], 21 inch [533 mm], 36 inch [914 mass flow sensor innovation, reducing the size mm], and 60 inch [1524 mm] lengths. All adjustable “U” elements of instruments, accelerating response time and include permanent, laser-etched depth gauge markings, in both improving overall operation in applications with inches and millimeters, to ensure accurate insertion depth within the “FP” Style dramatic temperature swings. Further, ST100 Element installation. Male NPT compression fittings are available in either Series flow elements are all-welded to ensure 3/4 inch or 1 inch, with Teflon or metal ferrules, or with a tapped and maximum strength, durability and leak prevention, threaded ANSI or DIN flange. Fixed length elements made to your and they are offered standard in either 316L specifications with a fixed threaded fitting or a welded ANSI or DIN stainless steel or Hastelloy-C276. flange are also available for all ST100 Series models. To maximize performance and long life for “S” Style For hot tap installations, retractable packing glands with a Element your applications, ST100 Series is engineered and choice of pressure rating and packing material are available for offered with a choice of flow element styles. The all ST100 insertion flow meter models. Pressure service ratings of FPC style is an exclusive FCI design that features a patent-pending either 50 psi [3,4 bar] or 500 psi [34 bar] are standard with higher flow conditioner, fast response time and a protective shroud. For ratings available on special request. To ensure compatibility with many applications with clean gases and for compressed air using an the process fluid and integrity of the installation, packing material is insertion style instrument, the FPC is the recommended solution. For selectable as either graphite or Teflon 1. the in-line Model ST100L, and instruments with the VeriCal option, the FP is the preferred solution. In other applications such as wet, In-line flow meter (Model ST100L) – The spool-piece flow body dirty, erosive, or corrosive gases or with rapidly changing flow rates, length is nine times its nominal diameter, and can be fabricated as where response time is less important, the S is regularly specified. required with male NPT, female NPT, ANSI flange or DIN flange and Table 1 provides a summary of conditions and characteristics to butt weld prepared process connections. consider in selecting a flow element style. 1 Teflon packing material may be required for certain process media such as ozone, chlorine or bromine; consult FCI’s AVAL program for recommendation ST100 Series Flow Element Selection 2 Chromium carbide coating also available ; contact FCI

Flow Element –FPC –FP –S Conditions or Characteristics All clean gases    Air / compressed air    Slightly dirty gases    Damp / moist gases    Very dirty gases    Wet gases    Erosive 2    Corrosive    Particulates in flow stream 2    Pulsing    Adjustable “U” Length Tapped and threaded Fast response time    with Compression Fitting ANSI or DIN Flange Dynamic temperature swings    Rapid or erratic changes in flow requir- ing smoothed response and output    Low Pressure Packing Gland Less-than-ideal straight run with Ball Valve (top) and    (without Vortab® flow conditioning) Medium Pressure Packing Gland with Ball Valve (right) Frequent cleaning required    With VeriCal option and STP1XX models   = Excellent performance, preferred solution  = Good performance, acceptable solution  = Not recommended

6 ST100 Series Insertion Flow Meters

Model ST100 ST102 ST110 ST112 STP100 STP102 STP110 STP112 Flow Element ­FPC Sensor Style a a ­FP Sensor Style a a a a a a a a S Sensor Style a a 316L SS Sensor a a a a a a a a Hastelloy-C276 Sensor a a All Welded Element a a a a a a a a Temperature Service ≤ 350 °F [177 °C] ≤ 350 °F [177 °C] ≤ 350 °F [177 °C] ≤ 350 °F [177 °C] Standard: 32 °F to 176 °F [0 °C to 80 °C] and Measuring Range ≤ 500 °F [260 °C] ≤ 500 °F [260 °C] ≤ 500 °F [260 °C] ≤ 500 °F [260 °C] Ex Rated: -22 °F to 212 °F [-30 °C to 100 °C] All ST models -40 °F [-40 °C] to: ≤ 850 °F [454 °C] ≤ 850 °F [454 °C] Limited by pressure ; contact FCI for special order, higher temp. service Pressure Measurement  0-50 psig [3,4 bar (g)]  0-500 psig [34 bar (g)] Ranges  0-160 psig [11 bar (g)]  0-1000 psig [70 bar (g)] Process Connections Compression Fittings with variable “U” length up to 6″, 12″, 21″, 36″ or 60″ [152 mm, 305 mm, 533 mm, 914 mm or 1524 mm] 3/4″ MNPT a a 1″ MNPT a a

Flange, Tapped and Threaded for 3/4″ NPT Compression Fitting a a

Retractable Packing Glands * with variable “U” length up to 6″, 12″, 21″, 36″ or 60″ [152 mm, 305 mm, 533 mm, 914 mm or 1524 mm] * Contact FCI for pressures > 500 psi [34 bar (g)] Low Pressure ≤ 50 psi [3,4 bar (g)] a a a a a a a a Medium Pressure ≤ 500 psi [34 bar (g)] a a a a a a a a Fixed specify “U” length up to 60″ [1524 mm] maximum 1″ MNPT a a a a a a a a Flanged a a a a a a a a

Single-point insertion flow meter for pipe For Line Sizes 1″, 1 1/2″, 2″ [25 mm, 40 mm, 51 mm] ST100L In-Line sizes 2 1/2″ [64 mm] and larger. Calibration ranges from 0.25 SFPS to 1000 SFPS [0,07 Model ST100L NMPS to 305 NMPS]. Flow Element – Models ST100, STP100 ­FP Sensor Style a S Sensor Style a 316L SS Sensor a In-line spool-piece flow meter for use in line sizes 1″, 1 1/2″, and 2″ [DIN25, DIN40, and DIN50]. Hastelloy-C276 Sensor a Typical calibration range is from 0.006 SCFM to All Welded Element a 838 SCFM [0,01 NCMH to 1425 NCMH].

Temperature Service ≤ 257 °F [125 °C] – Model ST100L

Process Connections 1″ Tubing a Dual-element insertion flow meters with 1″ Pipe a averaging mode for improved accuracy and repeatability in line sizes ≥ 12″ [305 mm]. 1 1/2 ″ Pipe a – Models ST102 A, ST112 A, STP102 A, STP112 A 2 ″ Pipe a NPT (Male) a NPT (Female) a ™ Flanged a VeriCal In-Situ Calibration models are insertion flow meters with the FCI exclusive Butt Weld a VeriCal in-situ calibration verification system.

– Models ST110, STP110, ST112, STP112

7 Two Sensor Averaging System

Applications involving line sizes 12 inches [305 mm] or greater With any two-element system, one element is always remote can realize improved installation accuracy and repeatability by mounted while the other may be integrally mounted or remote averaging the flow rates of two elements. Distorted, swirling mounted from the transmitter. and non-repeatable flow profiles can result in decreased accuracy of single point meters. In many cases, it is impractical or impossible to provide the required straight-run for a fully With Integral Configuration developed flow profile in large lines. Models ST102 A, ST112 A, STP102 A and STP112 A overcome these flow profile concerns with a simple, economical “dual-element averaging system.” The transmitter electronics will average the input from two independent flow elements into a single output. Each flow element can be independently configured for insertion length and process connection to allow installation flexibility. One flow element can be integral with the flow transmitter, or both can be configured as remote to accommodate easy access to terminal blocks and the optional digital display/optical four button interface. The flow transmitter also provides independent information for each flow element, saving time when performing service checks. To help determine if your application will benefit from using a dual-element averaging system, contact your With Remote Transmitter local representative or visit FCI online to utilize AVAL, FCI’s proprietary evaluation software.

8 Add Pressure Measurement with “STP” Models On-Board Data Logger

The “STP” models are the only thermal dispersion gas mass flow ST100 Series electronics include a user selectable and programmable meters available featuring pressure measurement to create a triple data logging feature. Readings are stored to a removable, internal, function solution (flow + temperature + pressure) in a single tap point board-mounted, micro-SD card (micro secure digital memory card). insertion instrument – an industry first and FCI exclusive feature. The supplied micro-SD card has a 2 GB capacity capable of storing A precision strain gauge pressure transducer is built into the approximately 21 million readings. Recording time base is user STP probe assembly and integrated into the transmitter inputs selectable with maximum rate of 1 reading per second. The logging and outputs. The transducer, connections and wiring assembly feature is selectable via the front panel menu or via the serial port are enclosed within a compact, protective aluminum housing and and configuration software tools. Readings are stored in ASCII, comma incorporated into the flow element assembly. Four pressure ranges separated format for easy uploading to spreadsheets such as MS-Excel. are available: 50, 160, 500 and 1000 psig [3,4; 11; 34 and 70 bar (g)] to maximize resolution and accuracy for your application. Pressure are available in both Ex and non-Ex rated types. Full Instrument Agency Approvals In addition to the labor savings over installing and running power to multiple sensors, bus communication installation reduces bus ST100 Series meters are agency approved for hazardous environment wiring, nodes and interfacing because all three measurements are installations. FCI products undergo rigorous agency testing and obtain their approvals on the entire instrument, not just the enclosure. This provided over a single bus connection. Analog outputs and alarm values highest level of agency certification is your evidence of FCI’s integrity. are also user assignable to pressure measurement as required by your This ensures that every FCI instrument meets the intended safety application. In STP models with the optional graphical/digital display, requirements of your installation. the pressure measurement value is added and continuously displayed. FM, FMc: Class I, Division 1, Explosion proof, Groups B, C, D Model STP100: Single-point insertion flow element with flow, Class II/III, Division 1, Dust ignition proof, Groups E, F, G temperature and pressure Class I, Division 2, Nonincendive, Groups A, B, C, D Model STP102: Dual-element insertion flow element; both Class II, Division 2, Nonincendive, Groups E, F, G elements with flow, temperature and pressure Class III, Division 1, 2, Dust ignition proof, indoor/outdoor Hazardous (classified) locations Model STP110: Single-point insertion flow element with flow, Type 4X/ IP67; NEC 500 temperature and pressure and VeriCal ATEX: EX d IIC Gb T6/T1 Ta = - 40°C to 65°C; Model STP112: Dual-element insertion flow element; both Ex tb IIIC T85°C/T450°C Db Ta = - 40°C to 65°C; IP67 elements with flow, temperature and pressure, IECEx : II 2 G Ex d IIC Gb T6/T1 Ta = - 40°C to 65°C; IP67 both elements with VeriCal CPA, NEPSI, Inmetro, EAC (TRCU) Russia CE approved, CRN Probe complies with Canadian Electrical code requirements of ANSI/ISA 12.27.01-2011 as a single seal device SIL 1 compliant FCI continually obtains additional agency approvals; contact FCI for availability of other agency approvals

Models STP100, Shown with optional Models STP110, STP102 low pressure packing gland STP112

9 VeriCal ™ In-Situ Calibration Verification g VeriCal kit with fixtures and fittings to meter and control a precise flow of nitrogen 4 across the ST flow element. The VeriCal Models ST110, ST112, STP110 and STP112 kit provides a specially designed 100 psig [6,9 bar (g)] pressure regulator and LCD digital pressure gauge packaged in a NEMA 4 g Validate performance on-site in minutes (IP66) rated enclosure, and a 25 foot [7,6 m] air hose with quick g Save costs, no need to remove flow meter from process disconnect fittings to connect the kit to the VeriCal ready flow element. The kit is fully portable or can be permanently mounted. g Comply with ISO and local regulations for periodic The VeriCal kit, part number 020849-03, is ordered separately as calibration verification a second line item. A single VeriCal kit can be used with and g Provides in-situ flow element cleaning support any number of VeriCal-ready flow elements. g Nitrogen source (user supplied) with a hose, regulated 125 psig Models ST110, ST112, STP110 and STP112 include FCI’s exclusive to 150 psig [8,6 bar (g) to 10,3 bar (g)], either from an installed plant and patented VeriCal system. VeriCal provides you with the ability to line or a portable supply tank. Typical test requires approximately perform periodic field validation and verification of the flow meter’s 40 ft3 [1,1 m3] of nitrogen. measuring performance and calibration without extracting the flow meter from the pipe or process. In gas flow processes with procedures or regulations requiring How It Works periodic calibration verification, an FCI flow meter configured with VeriCal provides the most convenient and lowest cost solution. With the VeriCal kit attached to the ST flow meter and the nitrogen Performing a verification with VeriCal also provides a secondary source, a positive-pressure nitrogen injection is introduced 4. With benefit of cleaning the flow element which helps ensure performance the ST flow element fully retracted from the actual flow stream and and reduce the need for routine maintenance. the ST set in the VeriCal Calibration group mode, the user adjusts the pressure at the VeriCal kit to inject small, controlled doses of nitrogen The VeriCal option is comprised of three components: at specific pressures (prescribed on the FCI VeriCal calibration g VeriCal ready flow element – This specially-constructed flow document). At each pressure point, flow readings are taken from the element includes a flow port at the sensors, internal tubing, sonic ST flow meter and compared to the respective baseline readings in nozzle and precision orifice, a ball valve to select “normal” or the documentation provided by FCI. This procedure is performed at “VeriCal” operation and a welded and sealed inlet check valve to initial installation, then as often as desired. prevent hazardous process gases from escaping. After the flow Model ST110: Single-point insertion flow meter configured meter system has been precision calibrated in FCI’s NIST traceable with VeriCal flow laboratory, the lab also performs an additional nitrogen Model ST112: Dual-element flow meter;both elements calibration and obtains five (5) baseline measurement points across configured with VeriCal the flow range to which all field checks using the VeriCal system are Model STP110: Single-point flow meter with pressure compared. With each ST110, ST112, STP110 or STP112, FCI provides measurement configured with VeriCal a second calibration curve and printed document showing the five Model STP112: Dual-element flow meter with pressuremeasurement baseline VeriCal flow readings for use by your field technicians. This option; both elements configured with VeriCal VeriCal calibration curve is stored within one of the ST100 Series’ P/N 020849-03: VeriCal kit five calibration groups. The VeriCal calibration is quickly and easily accessed and recalled from the first menu screen on the display. 4 Other gases may be used; contact FCI for specific information

10 FCI’s World Class Calibration Ensures Installed Accuracy

ST100 Series models are tested and calibrated to rigorous standards so that you get the instrument that does the job specified. To design and produce the highest quality flow instrumentation, FCI operates a world-class flow calibration laboratory with calibrations performed on more than 19 different flow stands, using equipment traceable to NIST (US National Institute of Standards and Technology), and ISO/IEC 17025 (International Standards for test lab quality systems). To achieve the highest possible accuracy in ST100 Series, Up to Five Unique Calibrations FCI utilizes these precision flow stands to flow actual gases and reference fluids matched to the temperature and process While a single calibration is sufficient for many operations, the conditions of your application. Further utilizing the extensive ST100 Series can provide up to five (5) unique calibration groups. flow laboratory capabilities, FCI has developed an all new, patent Depending on your application need, this feature can provide pending and scientifically engineered SpectraCal gas equivalency significant cost and time savings. Some examples include: algorithm as an economical alternative to actual gas calibration. Broaden measuring range – Extend the turndown ratio up to Other suppliers are often limited only to air calibrations 1000:1 or have different ranges for the same gas to maximize and rely on non-field tested or un-validated theoretical accuracy and resolution under changing conditions. This is equivalencies for other gases and gas mixtures. This procedure particularly beneficial with flares, which can require both a low can be inadequate and create measurement and output flow range for normal operation and leak detection, and also a errors well outside published specifications. FCI calibration very high flow range for upset conditions. Multiple calibration capabilities are un-matched in the industry, providing you with group settings saves on the cost of using multiple flow meters. total confidence that your installation meets its published specifications and your application needs. Different mixtures of same gases – Embed calibrations to optimize flow measurement accuracy in dynamic or seasonally affected processes (e.g. Digester Gas Group 1 is 65% CH , 35% More than 19 precision flow 4 stands to match NIST traceable CO2; Group 2 is 62% CH4, 38% CO2). fluids, process conditions, flow Different gases – Portable or temporary installations for rates and line sizes specified in your application. multiple applications, or to reduce spare parts inventory in plants with multiple installations and applications. Multiple gases, such as dual fuel sources (e.g. natural gas and propane).

11 ST100 Series Features

Four conduit ports provide greatest signal integrity and separation for power input, analog Extensive analog and digital communications output lines, digital I/O, relays and/or auxiliary input signals; choice of NPT or M20 threads output choices — Triple 4-20 mA with HART SIL 1 compliant — Foundation Fieldbus H1 AC or DC power supply — PROFIBUS PA — Modbus RS-485 Weather-proof, ruggedized, — 0-1 kHz or 0-10 kHz frequency or pulse Ex rated enclosures — USB port — Choices for local — Ethernet or remote mounting — NEMA 4X, IP67 On-board data logger — Aluminum standard, stainless steel optional Four (4) optical touch buttons — Proximity activation, no need to Global agency approvals of entire open enclosure instrument system for hazardous — Full instrument programmability location installations: — Protected against unwanted activation FM, FMc, ATEX, IECEx, NEPSI, CPA, Inmetro, EAC (TRCU) Russia Comprehensive informational display — Digital readout of all measured Multiple calibrations parameters; flow rate, total flow, — Up to five independent, separate calibrations temperature and pressure with — Multiple gases or mixed gas compositions engineering units — Same gas, different flow range to optimize — Analog flow rate bar graph accuracy and extend turndown up to 1000:1 — Alarm status indication Precision calibration and calibration choices — Instrument fault indication — Specific gas and application matched — User programmable 17 character field calibration using equipment traceable (example: display gas type, tag number or to NIST and ISO/IEC 17025 application/location) — Display orientation rotates in 90° Extensive selection of process connections increments electronically — Simple, adjustable installation with threaded — Backlighted: auto-on activation via NPT connector proximity sensor or set for always on — Teflon or metal ferrule seals — Fixed connections Multi-function: measures mass flow rate and — ANSI or DIN flanges temperature; STP Series adds — Retractable assemblies pressure measurement Stainless steel or Hastelloy-C276 wetted parts Permanent laser-etched depth gauge markings; ensures accurate centering of adjustable-length elements All welded sensor elements for maximum service life and leak-proofing Precision, wide-ranging platinum RTD sensors Exclusive equal mass sensors provide Choice of three flow element styles to optimize optimum performance in processes with wide application performance temperature swings — FPC style — FP style (shown) — S style

Optional stainless steel Optional enclosure sun shield

Remote up to 1000 ″ [300 m] ST100L in-line style ST100 with sun shield

12 ST100 Series Mass Flow Meter Specifications

Other: NEPSI, Inmetro, EAC (TRCU) Russia, CRN, CPA, CE marking Instrument Probe complies with Canadian Electrical code requirements g Measuring Capability of ANSI/ISA 12.27.01-2011 as a single seal device ST1XX Models: Flow rate, total flow and temperature

STP1XX Models: Flow rate, total flow, temperature and pressure g SIL: SIL 1 compliant g Basic Style SFF % AC Powered DC Powered ST100: Insertion, single-point Single element types 79.8 % 79.9 % ST100L: In-line (spool piece), single-point Dual element types 88.9 % 88.9 % ST102: Insertion, dual-element system g Calibration: Performed on flow stands with equipment traceable ™ ST110: Insertion, single-point with VeriCal capability to NIST and ISO/IEC 17025 ST112: Insertion, dual-element system with VeriCal capability STP100: Insertion, single-point with pressure measurement STP102: Insertion, dual-element system with pressure measurement Flow Element STP110: Insertion, single-point with pressure measurement g Material of Construction and VeriCal capability All-welded 316L stainless steel; Hastelloy-C optional STP112: Insertion, dual-element system with pressure measurement g Operating Pressure and VeriCal capability ST100, ST102, ST110, ST112 Insertion Style g Flow Measurement Range Metal ferrule: 1000 psig [70 bar (g)] Insertion Style: 0.25 SFPS to 1000 SFPS [0,07 NMPS to 305 NMPS] Teflon ferrule: 150 psig [10 bar (g)] (200 °F [93 °C] maximum) ST100L In-line: 0.0062 SCFM to 838 SCFM Fixed connection NPT: 1000 psig [70 bar (g)] [0,01 NCMH to 1425 NCMH] Fixed connection flanged: per flange rating – Air at standard conditions; 70 °F and 14.7 psia [0 °C and 1,01325 bar (a)] STP Models See pressure sensor specifications g Temperature Measurement Range Same as ST type above or per pressure sensor specification, whichever is lower Up to 850 °F [454 °C] commensurate with element; see Operating Model ST100L In-line style Temperature in Flow Element specification Tubing Sch 40 Pipe Sch 80 Pipe g Pressure Measurement Range (STP Models) Psig Bar(g) Psig Bar(g) Psig Bar(g) Available Ranges: F Style Sensor 0 psig to 50 psig [0 bar (g) to 3,4 bar (g)] 1 ″ 2400 165 2500 172 3000 207 0 psig to 160 psig [0 bar (g) to 11 bar (g)] 1 1/2 ″ 1750 121 2500 * 172 * 2 ″ 1500 103 2250 * 155 * 0 psig to 500 psig [0 bar (g) to 34 bar (g) S Style Sensor 0 psig to 1000 psig [0 bar (g) to 70 bar (g)] 1 ″ 2400 165 2500 172 2500 172 g Media: All gases that are compatible with the flow element material 1 1/2 ″ 1750 121 2500 * 172 * 2 1500 103 2250 * 155 * g Accuracy ″ Flow: Gas specific calibration: ± 0.75% reading, ± 0.5% full scale * 1 1/2 ″ and 2 ″ Sch 80 available by special order only; contact FCI 3/4 ″ pipe also available by special order Temperature: ± 2 °F [± 1,1 °C] (display only, flow rate must be greater g than 5 AFPS [1,5 m/sec]) Operating Temperature (Process) Pressure (STP Models): ± 1.0% of span ST100, ST102 Insertion Style g Temperature Coefficient All Flow Elements (FPC, FP and S): With optional temperature compensation; valid from 10% to 100% of -40 °F to 350 °F [-40 °C to 177 °C] full scale calibration -40 °F to 500 °F [-40 °C to 260 °C] -40 °F to 850 °F [-40 °C to 454 °C] Flow: Maximum ± 0.015% of reading / °F up to 850 °F [± 0.03% of reading / °C up to 454 °C] ST110, ST112 Insertion Style FP Style Flow Element: g Repeatability -40 °F to 350 °F [-40 °C to 177 °C] Flow: ± 0.5% reading -40 °F to 500 °F [-40 °C to 260 °C] Temperature: ± 1 °F [± 1 °C] (flow rate must be greater than 5 AFPS [1,5 NMPS]) STP Series Insertion Style FP Style Flow Element: Pressure (STP Models): ≤ 0.1% of span Standard: 32 °F to 176 °F [0 °C to 80 °C] g Turndown Ratio Ex Rated: -22 °F to 212 °F [-30 °C to 100 °C] Normally factory set and field adjustable from 2:1 to 100:1 within Limited by pressure transducer; contact FCI for special order, higher calibrated flow range; up to 1000:1 possible with factory evaluation of temperature service application ST100L In-line Style g Temperature Compensation FP and S Style Flow Element: Standard: ± 30 °F [± 16 °C] -40 °F to 257 °F [-40 °C to 125 °C] Optional: ± 100 °F [± 55 °C] g Process Connection g Agency Approvals FM, FMc: Class I, Division 1, Explosion proof, Groups B, C, D Compression Fittings Models ST100 and ST102 only Class II/III, Division 1, Dust ignition proof, Groups E, F, G 3/4″ or 1″ male NPT, stainless steel with adjustable Teflon ferrule or metal Class I, Division 2, Nonincendive, Groups A, B, C, D ferrule; or flanged tapped and threaded for 3/4″ fitting, ANSI or DIN flanges Class II, Division 2, Nonincendive, Groups E, F, G Compression fittings not available with 850 °F [454 °C] temperature Class III, Division 1, 2, Dust ignition proof, indoor/outdoor versions of ST100 or ST102 Hazardous (Classified) locations Retractable Packing Glands Type 4X/ IP67 (per NEC 500) Low pressure 50 psig [3,5 bar (g)] or medium pressure 500 psig [34 bar (g)] ATEX: EX d IIC Gb T6/T1 Ta= - 40°C to 65°C; with graphite or Teflon packing material; 1 1/4″ male NPT or ANSI or DIN Ex tb IIIC T85°C/T450°C Db Ta = - 40°C to 65°C; IP67 flange IECEx : II 2 G Ex d IIC Gb T6/T1 Ta = - 40°C to 65°C; IP67 Teflon packing required when process media is ozone, chlorine or bromine; remote mount required when medium pressure packing gland is required

ST100 Series specifications continued on next page 13 ST100 Specifications Cont’d

Fixed Fittings / All Welded g Enclosures 1″ male NPT or ANSI or DIN flange Main Transmitter / Electronics Insertion Length NEMA 4X, IP67; polyester powder coated aluminum or optional in Field adjustable lengths: stainless steel; 4 conduit ports threaded as 1/2 ″ NPT or M20x1.5; 7.74 ″ x 1″ to 6″ [25 mm to 152 mm] 5.40 ″ x 5.00 ″ [196,6 mm x 137,2 mm x 127 mm] 1″ to 12″ [25 mm to 305 mm] Local Enclosure (Remote Configuration): 1″ to 21″ [25 mm to 533 mm] Model ST100L, Models ST100 and ST102 without packing gland option: 1″ to 36″ [25 mm to 914 mm] NEMA 4X, IP67; polyester powder coated aluminum; 2 conduit ports threaded 1″ to 60″ [25 mm to 1524 mm] as 1/2 ″ NPT or M20x1.5; 3.75 ″ x 4.00 ″ x 3.24 ″ [95 mm x 102 mm x 82 mm] Fixed lengths from 2.6″ to 60″ [66 mm to 1524 mm] Models ST100 and ST102 with packing gland option; ST110, ST112 g ST100L In-line Flow Tube and all STP Models: Flow element is welded to an in-line flow tube, calibrated and supplied as a spool- NEMA 4X, IP67; polyester powder coated aluminum; 1 conduit port threaded piece; options include low flow injection tubes and built-in Vortab flow conditioners as 1 ″ NPT or M20x1.5; 5.40 ″ x 4.82 ″ [137,2 mm x 122 mm] for optimum low flow rangeability and performance All models with stainless steel enclosure option: Size: 1″ diameter tubing; 1″, 1 1/2″ or 2″ schedule 40 pipe Length: 9 nominal diameters NEMA 4X, IP67; stainless steel; 1 conduit port threaded as 1 ″ NPT or Process Connections: Female NPT, male NPT, ANSI or DIN flanges, or M20x1.5; 5.40 ″ x 4.82 ″ [137,2 mm x 122 mm] butt weld prepared g Data Logger Option: Flanges sized for flow tube User programmable for readings per time increment to a maximum of g Remote Transmitter Configurations:Transmitter may be mounted remotely 1 reading/second; removable, circuit board-mountable 2 GB micro-SD from flow element using interconnecting cable (up to 1000′ [300 m]); remote (secure digital) memory card supplied; stores approximately 21 M configuration required with medium pressure packing gland process connection readings in ASCII comma-separated format g g STP Models: Specifications on Pressure Sensor Readout/Display and Optical Touch Buttons Optional . Large 2 x 2 [50 mm x 50 mm] LCD; digital plus bar graph and Standard Sensor PSI Bar PSI Bar PSI Bar PSI Bar ″ ″ Pressure range 50 3,4 160 11 500 34 1000 70 engineering units Over pressure safety 100 7 290 20 1000 70 1740 120 . Digital displays of flow rate, total flow, temperature and pressure Burst pressure 250 17,24 500 34 2500 172 7975 550 (with STP models); user selectable for engineering units Wetted Materials: . Analog bar graph of flow rate Connection 316L 316L 316L 316L Pressure Sensor PH 13-8 SS 316L 316L 316L . Alarm status indication . User programmable 17 alphanumeric character field associated with Ex Rated Sensor PSI Bar PSI Bar PSI Bar PSI Bar each calibration group Pressure range 50 3,4 160 11 500 34 1000 70 Over pressure safety 240 16,55 1160 80 1160 80 1740 120 . Set-Up & Service mode displays text and service codes Burst pressure 290 20 1390 95,84 5800 400 7970 549,5 . Backlighted – backlight activated by proximity motion detection, or Wetted Materials: user may set for always on Connection Stainless steel Stainless steel Stainless steel Stainless steel Pressure Sensor Stainless steel Stainless steel SS and Elgiloy SS and Elgiloy . Four (4) optical touch buttons for user programming of instrument set- up and service interrogation . Optical touch button activation through front window – no need to Flow Transmitter/Electronics open enclosure to access or activate g Operating Temperature: . Display is electronically rotatable in 90° increments to optimize Single element models: -40 °F to 150 °F [-40 °C to 65 °C] viewing angle Dual element models: ST102, ST112, STP102, STP112 Note: If readout/display not ordered, all user set-up and service inter- -40 °F to 120 °F [-40 °C to 49 °C] rogation must be done via computer link to bus comm and/or USB port. g Input Power AC: 85 Vac to 265 Vac, 50 Hz to 60 Hz; Other Options Single element: 10 watt; dual element: 13.1 watt maximum g DC: 24 Vdc ± 20%; Vortab Flow Conditioners Single element: 9.6 watt; dual element: 13.2 watt maximum Available for all line size applications; standard choice with Model ST100L (in-line) g Outputs g Sun Shield Analog Shades main transmitter, electronics and display from direct sunlight; * Standard: Three (3) 4-20 mA , 0-1kHz, or 0-10 kHz pulse/frequency 316L stainless steel 4-20 mA outputs are user assignable to flow rate, temperature and/or if FCI PN 023241-01 Integral transmitter so equipped, pressure; outputs are user programmable to full flow range FCI PN 023237-01 Remote transmitter or subsets of full flow range; pulse/frequency output is user selectable g as pulse for external counter/flow totalizer, or as 0-1 kHz or 0-10 kHz Ball Valves / Cable Glands frequency representing flow rate g Element Coatings and Materials * Outputs are isolated and have fault indication per NAMUR NE43 For service in highly corrosive gases or with erosive particulates, FCI can guidelines, user selectable for high (> 21.0 mA) or low (< 3.6 mA) provide special coatings and wetted materials to protect the element and provide longer service life; examples include Kynar, Tantalum, and Digital chromium carbide Standard: USB, Ethernet (for use in configuration and as service port) g Optional: HART (comes standard with analog outputs, V7 compliant) Certification and Testing Documentation Foundation Fieldbus H1, PROFIBUS PA or Modbus RS-485 g Auxiliary Inputs Specifications at reference operating conditions of 70 °F, 14.7 psia [21,1 °C, 1013 4-20 mA input channel used for FCI administered special configurations bar (a)] and straight pipe run 20 d upstream, 10 d downstream to allow ST100 Series to accept inputs from external devices such as FCI is a continuous improvement company; specifications subject to change without gas analyzers, gas composition or pressure sensors notice 14 Model ST100L In-Line Flow Meter ModelModel ST100L ST100L In-Line In-Line Flow Flow Meter Meter In-LineIn-LineIntegral Configuration Configuration Configuration

Enclosure meets explosion Enclosureproof, water meets and explosion dust tight 5.00 proof, water and dust tight 5.00 approvals (see manual for 127 approvalsspecific (seeapproval manual types) for 127 specific approval types) Optional display Optional display 7.75 1/2 inch NPT 7.75197 5.40 1/2 inch NPT 5.40 or M20X1.5 197 Mounting orientation 137 or M20X1.5 Mounting orientation 137 9.98 of flats to be parallel to flow 9.98 of flats to be parallel to flow 253 253 Flow direction External ground screw Flow direction External ground screw

Sensor element types: Sensor"S" style element (shown) types: 1/2 X˚ Optional Vortab "S" style (shown) 1/2 X˚ Optional Vortab "F" style (optional) "F" style (optional) X˚ X˚ 7 Dia 2 Dia 2x flanged 7 Dia 2 Dia 2x processflanged connections "A" Length process connections "A" Length

3.63 4.13 3.6392 4.13105 92 105

Remote Transmitter RemoteRemote Transmitter Transmitter

Enclosure meets explosion Enclosure meets explosion proof, water and dust tight 3.27 3.75 proof,approvals water and(see dust manual tight for 3.27 3.75 approvals (see manual for 83 2X 1/2 NPT 95 specific approval types) 83 2Xor 1/2 M20X1.5 NPT 95 specific approval types) or M20X1.5 3.56 Mounting orientation 3.56 External Mounting orientation 91 of flats to be parallel to flow 91 7.34 groundExternal screw of flats to be parallel to flow 7.34186 ground screw Flow direction 186 Flow direction Sensor element types: 1/2 X° Sensor"S" style element (shown) types: 1/2 X° "S""F" style style (shown) (optional) X° "F" style (optional) X° Optional Vortab Optional Vortab 2x flanged 2x processflanged connections 7 Dia 2 Dia process connections 7 Dia 2 Dia "A" length "A" length

7.75 5.00 7.75 5.00 197 1/2 inch NPT 127 197 Optional display 127 1/2or inch M20X1.5 NPT Optional display or M20X1.5 External Externalground screw ground screw 10.00 10.00254 ø.27 TYP 254 3.50 2.75 ø.27 TYP7 3.5089 2.7570 7 89 70 Optional, Optional,aluminum "L" bracket aluminum "L" bracket 1.75 4.50 1.75 44 4.50114 2.25 44 114 2.2557 57 2.80 7.00 2.8071 7.00178 71 178

15 Model ST100 SingleModel Point ST100 & Single ST102 PointDual Point& ST102 Dual Point Insertion Flow Insertion Meter Flow Meter Model ST100 Single-Point,Integral ST102 Configuration Dual-ElementIntegral Configuration Insertion Flow Meter Integral Configuration

Compression fitting, Compression fitting, optional teflon or metal ferruleoptional teflon or metal ferrule

Process connection: Process connection: Display, Optional Display, Optional Compression fitting, optional.Compression fitting, optional. Teflon or Metal ferrule; Teflon or Metal ferrule; 3/4 inch or 1 inch NPT 3/4 inch or 1 inch NPT .80 .80 5.00 5.00 20 20 127 127

Horizontal flow orientationHorizontal flow orientation 10.00 Max 10.00 Max "U" length "U" length shown shown 254 254

Enclosure meets explosionEnclosure meets explosion proof, water and dust tightproof, water and dust tight approvals (see manual forapprovals (see manual for specific approval types) specific approval types) 5.40 5.40 External grounding External137 grounding Mounting137 orientation of Mountingflats orientation of flatsVertical flow orientationVertical flow orientation screw screw to be parallel to flow to be parallel to flow shown shown "S" Style head "S" Style head

7.75 7.75 .88 .88 197 197 22 22

4X 1/2 NPT or M20X1.5 4X 1/2 NPT or M20X1.5"FP" or "FPC" Style head "FP" or "FPC" Style head

Remote TransmittersRemote Transmitters

With Ferrule typeWith Ferrule typeRemote Transmitter With Packing glandWith Packing gland Compression fittingCompression fitting With Ferrule Type Compression Fitting With Packing Gland

Enclosure meets explosionEnclosure meets explosion proof, water and dust tight proof, water and dust tight 4.68 5.03 4.68 5.03 approvals (see manual for approvals (see manual for 119 128119 128 specific approval types) specific approval types) Enclosure meets 2X 1/2 NPT or M20X1.5 2X 1/2 NPT or M20X1.5 Enclosure meets explosion proof, water explosion proof, water and dust tight approvalsand dust tight approvals 3.27 3.753.27 3.75 4.69 4.69 (see manual for specific(see manual for specific 83 9583 approval types) 95 119 119 approval types) 1 inch NPT 1 inch NPT 3.56 3.56 14.61 3.61 14.61 3.61 90 90 371 92 371 92 Mounting orientation Mounting orientation 8.00 Max 8.00 Max MAX MAX of flats to be parallel of flats to be parallel 203 203 to flow to flow 6.31 6.31 2.19 2.19 Mounting orientation of flats 160 160 56 Mounting orientation of flats 56 to be parallel to flow to be parallel to flow 1 1/4 inch NPT packing gland.1 1/4 inch NPT packing gland. Teflon or graphite packingTeflon or graphite packing 3/4 inch tube 3/4 inch tube Process connection: "U" length Process connection: material (optional flangedmaterial (optional flanged "U" lengthCompression fitting, optional.Compression fitting, optional. "U" length type provided) type provided) Teflon or metal ferrule; Teflon or metal ferrule; "U" length 3/4 inch or 1 inch NPT 3/4 inch or 1 inch NPT 3/4 inch pipe 3/4 inch pipe

"S" Style head "S" Style head .80 .80"FP" or "FPC" Style head "FP" or "FPC" Style head 1.13 1.13 20 20 29 29 "FP" or "FPC" Style head "FP" or "FPC" Style head "S" Style head "S" Style head

7.75 7.75 197 197 5.00 5.00 1/2 inch NPT 1/2 inch NPT 127 127 or Optionalor Display Optional Display M20X1.5 M20X1.5 External ground screw External ground screw 5.40 5.40 137 137 10.00 10.00 254 254 10.00 10.00 .27 254 3.50 2.75 3.50 2.75 .27 254 7 89 70 89 70 7 TYP TYP Aluminum "L" bracket Aluminum "L" bracket 1.75 1.75 2.25 442.25 44 4.50 4.50 57 57 114 114 2.80 2.80 7.00 7.00 71 71 178 178 16 Models ST110 Single Point With Verical & ST112 Dual Point With Verical Models InsertionST110 Single Flow Point Meter With Verical Model ST110 Single-Point,& ST112Integral Dual ST112 Configuration Point Dual-Element With Verical Insertion Flow Meter Insertion Flow Meter 4X 1/2 inch NPT Integral Configuration or M20x1.5 Integral Configuration1 1/4 inch NPT packing gland; VeriCal box assembly Teflon or graphite packing material 4X 1/2 inch NPT (optional flanged type provided) or M20x1.5 1 1/4 inch NPT packing gland; VeriCal box assembly Teflon or graphite packing material (optional flanged 1.13 type provided) 7.75 29 197 1.13 29 7.75 1/4 turn plug valve 197 "FP" Style head External grounding 1/4 turn plug valve "FP" Style head External grounding Enclosure meets explosion proof, water and dust tight Mounting orientation 5.40 of flats to be parallel to flow approvals (see manual for 137 specificEnclosure approval meets types) explosion 1/8 inch hose plug proof, water and dust tight Mounting orientation 5.40 of flats to be parallel to flow 3/4 inch pipe approvals (see manual for 137 specific approval types) N2 in 1/8 inch hose plug 5.00 127 3/4 inch pipe N2 in "FP" Style head 5.00 127 8.00 8.75 2.00 "FP" Style head 203 222 51

8.00 25.068.75 2.00 "U" length 203 637222 51

25.06 "U" length 637 Remote Transmitters RemoteRemote TransmittersTransmitter

1 inch NPT 1 1/4 inch NPT packing gland; Teflon or graphite packing material (optional flanged type provided) 1 inch NPT 1/4 turn plug valve 1 1/4 inch NPT packing gland; Teflon or graphite packing material (optional flanged type provided) 1/4 turn plug valve

Enclosure meets explosion 1.13 proof, water and dust tight 1/8 inch hose plug 29 approvals (see manual for VeriCal box assembly specificEnclosure approval meets types) explosion 1.13 proof, water and dust tight 1/8 inch hose plug 29 24.50 "U" approvals (see manual for VeriCal box assembly specific approval types) 622 length 4.69 8.75 6.31 119 22224.50 160 "U" 4.68 622 length 119 4.69 8.75 6.31 119 222 N2 160in 4.68 5.74 119 146 "FP" Style head N2 in 5.74 2.31146 59 "FP" Style head 5.23 1332.31 59 7.75 5.23 5.00 197 133 127 4X 1/2 inch NPT External ground screw 7.75 or Optional Display 5.00 197 M20X1.5 127 4X 1/2 inch NPT External ground screw 5.40 or Optional Display 137 10.00 M20X1.5 254 7.50 5.40 3.50 2.75 .27 TYP 191 137 10.00 89 70 254 7 7.50 Aluminum "L" bracket 3.50 2.75 .27 TYP 191 89 70 1.75 4.50 44 7 114 2.25 Aluminum "L" bracket 1.75 57 4.507.00 2.8044 114178 71 2.25 57 7.00 2.80 178 71 17 Models STP100 Single Point With Pressure & STP102 Dual Point With Pressure Models STP100Insertion Single Flow Point Meter With Pressure Model STP100 Single-Point,& STP102Integral STP102Dual Configuration Point Dual-Element With Pressure Insertion Flow Meter Insertion Flow Meter 4x 1/2 inch NPT or M20x1.5 IntegralIntegral Configuration Configuration Pressure transducer 1 1/4 inch NPT packing gland; assembly housing Teflon or graphite packing material 4x 1/2 inch NPT (optional flanged type provided) or M20x1.5 Pressure transducer 1 1/4 inch NPT 1.13 packing gland; assembly housing Teflon or graphite29 packing material 7.75 (optional flanged type provided) 197 1.13 7.75 "FP"29 Style head 197 External grounding

"FP" Style head

Enclosure meets explosion External grounding proof, water and dust tight Mounting orientation approvals (see manual for 5.40 of flats to be parallel to flow specific approval types) 137 Enclosure meets explosion proof, water and dust tight Mounting orientation 3/4 inch pipe approvals (see manual for 5.40 of flats to be parallel to flow specific approval types) 137 5.00 127 3/4 inch pipe "FP" Style head 5.00 127 8.00 8.75 2.00 203 222 51 "FP" Style head

25.06 "U" length 8.00 8.75637 2.00 203 222 51

25.06 "U" length 637 Remote Transmitters Remote Transmitter

1 inch NPT Remote Transmitters 1 1/4 inch NPT packing gland; Teflon or graphite packing material (optional flanged type provided)

1 inch NPT 1 1/4 inch NPT packing gland; Teflon or graphite packing material (optional flanged type provided)

Enclosure meets explosion 1.13 proof, water and dust tight 29 approvals (see manual for specific approval types) Pressure transducer Enclosure meets explosion assembly housing 1.13 proof, water and dust tight 24.41 "U" 29 approvals (see manual for 620 length specific approval types) Pressure transducer 4.69 8.75assembly housing6.31 119 24.41222 160 "U" 4.68 620 length 119 4.69 8.75 6.31 5.74 119 222 160 4.68 146 119 "FP" Style head 5.74 2.31146 59 "FP" Style head 5.23 1332.31 59 5.23 7.75 7.00 133 178 197 1/2 inch NPT External ground screw or Optional Display M20X1.5 7.75 7.00 178 197 1/2 inch NPT 5.40 External ground screw or Optional Display 137 10.00 M20X1.5 10.00 254 254 5.40 3.50 2.75 .27 TYP 137 89 70 10.00 7 10.00 Aluminum "L" bracket 254 254 3.50 2.75 1.75 4.50 44 .27 TYP 89 70 7 114 2.25 Aluminum "L" bracket 57 7.00 2.801.75 1784.50 7144 114 2.25 57 7.00 2.80 18 178 71 Models STP110 Single Point With Pressure and Verical & STP112 Dual Point With Pressure and Verical Model STP110Models Single-Point, STP110 Insertion Single STP112 Point Dual-ElementFlow With Meter Pressure Insertion and Flow Verical Meter & STP112 DualIntegral Point Configuration With Pressure and Verical

4x 1/2 inch NPT Insertion Flow Meter or M20x1.5 Integral Configuration VeriCal and pressure transducerIntegral Configuration1 1/4 inch NPTpacking gland; assembly housing Teflon or graphite packing material 4x 1/2 inch NPT (optional flanged type provided) or M20x1.5 VeriCal and pressure transducer 1 1/4 inch NPTpacking gland; assembly housing Teflon or graphite 1.13 packing material 7.75 (optional flanged29 type provided) 197 1.13 29 7.75 1/4 turn plug valve "FP" Style head 197 External grounding

1/4 turn plug valve "FP" Style head Enclosure meets explosion External grounding proof, water and dust tight Mounting orientation approvals (see manual for 5.40 of flats to be parallel to flow specific approval types) 137 Enclosure meets explosion 1/8 inch hose plug proof, water and dust tight Mounting orientation 3/4 inch pipe approvals (see manual for 5.40 of flats to be parallel to flow specific approval types) 137 N2 in 1/8 inch hose plug 5.00 127 3/4 inch pipe N2 in "FP" Style head 5.00 127 8.00 8.75 2.00 203 222 51 "FP" Style head

25.06 8.00 8.75 2.00 "U" length 203 637222 51

25.06 "U" length 637 Remote Transmitters

RemoteRemote Transmitters Transmitter 1 inch NPT 1 1/4 inch NPTpacking gland; Teflon or graphite packing material (optional flanged type provided) 1/4 turn plug valve 1 inch NPT 1 1/4 inch NPTpacking gland; Teflon or graphite packing material (optional flanged type provided) 1/4 turn plug valve Enclosure meets explosion 1.13 proof, water and dust tight 29 approvals (see manual for 1/8 inch hose plug specific approval types) VeriCal and pressure Enclosure meets explosion transducer assembly housing 1.13 proof, water and dust tight 29 approvals (see manual for 1/8 inch hose plug specific approval types) 24.50 VeriCal and pressure "U" 622 transducer assembly housing length 4.69 8.75 6.31 119 22224.50 160 "U" 4.68 622 length 119 4.69 8.75 6.31 119 222 N2 in160 4.68 5.74 119 146 "FP" Style head N2 in 5.74 2.31146 59 "FP" Style head 5.23 1332.31 59 5.23 7.75 133 197 5.00 1/2 inch NPT 127 External ground screw or Optional Display 7.75 M20X1.5 197 5.00 1/2 inch NPT 127 External ground screw Optional Display 5.40 or 137 10.00 M20X1.5 10.00 254 254 3.50 2.75 .27 TYP 5.40 70 7 137 10.00 89 10.00 254 254 Aluminum "L" bracket 2.75 .27 TYP 3.50 4.50 70 1.75 7 89 114 44 Aluminum "L" bracket 2.25 7.00 57 4.50 1.75 178 2.80 114 71 44 2.25 7.00 57 2.80 178 19 71 Locally Represented By: Visit FCI online at www.FluidComponents.com | FCI is ISO 9001 and AS 9100 Certified FCI World Headquarters 1755 La Costa Meadows Drive | San Marcos, California 92078 USA Phone: 760-744-6950 Toll Free (US): 800-854-1993 Fax: 760-736-6250

FCI Europe Persephonestraat 3-01 | 5047 TT Tilburg, The Netherlands | Phone: 31-13-5159989 Fax: 31-13-5799036

FCI Measurement and Control Technology (Beijing) Co., LTD | www.fluidcomponents.cn Room 107, Xianfeng Building II, No.7 Kaituo Road, Shangdi IT Industry Base, Haidian District | Beijing 100085, P. R. China Phone: 86-10-82782381 Fax: 86-10-58851152

0816 500 Doc. No. 02MK011474 F

© Copyright 2010 by Fluid Components International LLC. All rights reserved. Manufactured in accordance with one or more of the following patents: US Patent Numbers: 4,981,368, 5,111,692, 5,117,216, 5,134,772, 5,152,049, 5,167,153, 5,780,737, 5,600,528, 5,913,250, 6,208,254, 6,340,243, 6,628,202, 6,843,110, 7,191,645; China Patent Numbers: ZL00815586.0, ZL03817053.1. FCI is a registered trademark of Fluid Components International LLC. Information subject to change without notice.

HART® is a registered trademark and Foundation™ Fieldbus is a trademark of FieldComm Group