The Influence of System Design, Station Operations and Cycle Chemistry on Corrosion Product Generation and Flow-Accelerated Corr

Total Page:16

File Type:pdf, Size:1020Kb

The Influence of System Design, Station Operations and Cycle Chemistry on Corrosion Product Generation and Flow-Accelerated Corr The Influence of System Design, Station Operations and Cycle Chemistry on Corrosion Product Reprint R-983E Generation and Flow-Accelerated Corrosion (FAC) at Coryton Combined Cycle Gas Turbine (CCGT) Power Station By: Richard Herbert, Science Officer, Coryton Power Station Peter de Graaf, Industry Development Manager, Nalco Europe BV Peter Blokker, Staff Scientist, Nalco Europe BV Charles A. Campbell, Key Account Manager, Nalco Ltd. ABSTRACT INTRODUCTION A systematic study of the influence of system The practical measurement of oxidation-reduction design, station operations and cycle chemistry on potential (ORP) of condensate and feedwater at corrosion product generation and flow-accelerated operating temperature and pressure can provide corrosion (FAC) was carried out at Intergen’s visibility to unfavorable conditions or events. Coryton CCGT in Essex, UK. Coryton is a modern These conditions or events impact plant reliabil- 779 MW two-by-one combined-cycle natural gas ity, thermal efficiency and plant emissions, and plant equipped with an air-cooled condenser (ACC). require both identification and development of The plant was designed and constructed for opera- strategies to prevent damage. It is usual to monitor tional flexibility and functional efficiency in a mer- and control pH, dissolved oxygen, acid conductivity chant power environment, which in practice means and, when used, reducing agent residual, and to a cycling operation with occasional two-shifting. consider these parameters as an indirect measure The study was instigated by the frequent occurrence of the corrosion potential of the water. Corrosion of FAC in combined cycle power plants and the ret- products are released every time there is a ther- rospective nature of non-destructive testing (NDT). mal, chemical, or hydraulic shock to the system. The station wanted to invest in advanced monitor- Intermittent corrosion product monitoring often ing techniques with the objective of reducing corro- leads to questions on the validity and interpreta- sion in the air-cooled condenser and the potential tion of the data produced. Grab sampling only for FAC in the heat recovery steam generator provides a snapshot, but if the full extent of the (HRSG) during normal and cycling operations, and events could be made visible, responses can be to determine the impact of cycling operation on unit developed to minimise corrosion and iron trans- life expectancy and reliability. Of special interest port. The results from particle monitoring can be was the evaluation of the use of all-volatile treat- related to particulate iron levels with sensitivity ment oxidising (AVT-O) versus all-volatile treat- in the ppb range. Moreover, the results from ment reducing (AVT-R) chemistry control in the particle monitoring can be correlated to the ORP all-steel system as a means to reduce FAC in the at operating temperature and pressure. HRSG and iron pick-up in the air-cooled condenser. On-line “at-temperature” Oxidation-Reduction Potential and Particle Monitor instruments were FLOW-ACCELERATED CORROSION applied to supplement the standard array of chem- Consensus has formed about the causes of Flow- istry and operational monitoring. The study should Accelerated Corrosion (FAC): these include mate- allow Coryton Power to identify the best cycle chem- rials of construction and geometry, low pH, low istry control specifications to minimise FAC and oxygen concentration, rapid or turbulent flow, and ACC corrosion, leading to more reliable, efficient temperatures of ca. 150°C ± 50°C. The economizer and lower cost generation for the life of the plant. outlet (typically single-phase) and the LP evapo- rator section (two-phase) are particularly susceptible to FAC, especially the upper bends and the upper header of the evaporator tubes. The metal Presented at PowerGen Europe, Netherlands, 8-11 June, 2010 wastage mechanism is accelerated by flow hydro- temperature oxidation-reduction potential (RT dynamics, but the basic process is the dissolution ORP), provides a much better technical solution. of magnetite, which is directly related to the oxi- AT ORP is a more sensitive and realistic indicator dation-reduction potential at system temperature of the actual condition at the system’s metal sur- and pressure. If the rate of dissolution of magne- faces. Research by Nalco on AT ORP measurement tite exceeds magnetite formation, then the metal and control resulted in the development of a reli- surface becomes less protective resulting in tube able, sensitive, high-temperature probe and control thinning, which impacts station reliability and strategy that allow power stations to operate at a integrity. constant AT ORP value that facilitates the forma- 5,6 The Electric Power Research Institute (EPRI) sug- tion of protective metal surfaces . gests that iron measurements can be used as an The ideal monitoring programme would correlate indicator for FAC. As the dissolution of magnetite the interplay of the oxidising environment with results in the formation of iron hydroxide, the spe- all of the relevant variables contributing to sys- cies of iron present can also be relevant. Particles tem corrosion and FAC across the AT ORP “space” of iron oxide may be dislodged when the passive and relate that to corrosion product generation and film is disrupted by magnetite dissolution, contrib- transport (Figure 1). The diagnostic and preven- uting to the particulate levels and iron balance. tative value of this approach will be discussed in a EPRI suggests that high iron levels, under severe case history format that describes the initial out- FAC conditions, always consist of over 95% come of a study which is currently in progress. This particulate iron1. All of the above considerations study was prompted by the frequent occurrence of contribute to make the measurement of the oxida- FAC in combined cycle power plants, the retrospec- tion-reduction potential at operating temperature tive nature of non-destructive testing (NDT), the and pressure and particle monitoring a vital part need for advanced diagnostic information, and the of a FAC monitoring programme. evaluation of cycle chemistry improvements. Specific mechanical and operational factors can- not be changed in most existing systems. The ques- tion of using reducing agents for metal surface Removal passivation complicates matters. Long considered Particle ofsurface monitoring a best practice, institutes like EPRI now recom- Iron mend against the use of reducing agents in all- steel systems, citing evidence that they increase M l s a e s u e c y t r ta et a t a f FAC by increasing the dissolution rate of magne- f li b a l M r i i c u b li e s a t t y tite in the more reducing environment. However, s Ions when station operations, such as cycling or Temperature Plant design Flow two-shifting, results in high variability in the Metallurgy Plantoperation Water pH at-temperature ORP environment, then the com- Constructionmaterials quality DO position and properties of the passivation layer will Watertreatment … ATͲORP Reductant also be in constant flux and under stress. Variable … at-temperature ORP values lead to variable oxides with variable density and protective properties. Additionally, there are many systems where Figure 1 — Holistic representation of how mechanical oxygen removal in the condenser is so design, operating conditions and cycle chemistry influence the metal surface stability. effective that the feedwater system runs in a reduced state even with no reducing agent present. The opposite can also be observed in stations that experience highly variable oxygen levels, in excess of 10 ppb, during cycling and two-shifting. Although EPRI has recommended against the use CASE STUDY – CORYTON POWER of a reducing agent in all-steel systems, they sug- STATION gest using ORP measured in-situ as a means of Coryton Power is a modern 779 MW two-by-one 2 controlling feedwater chemistry . For all- steel sys- combined-cycle natural gas power station equipped tems they suggest a room temperature ORP value with an air-cooled condenser (ACC) and a pre-coat between 0 and +100 mV (Ag/AgCl , saturated KCl 2 filter for particulate matter removal from the reference electrode). Research by Nalco has dem- steam condensate. The plant was designed and onstrated that oxidation-reduction potential constructed for operational flexibility and func- should be measured at operating temperatures and tional efficiency in a merchant power environment, ® 3 pressures (AT ORP ) . Using the Nalco AT ORP which in practice means a cycling operation with 4 technologies for high-temperature and pressure occasional two-shifting. evaluation of corrosion stress, as compared to room 2 Picture 1 – Coryton Energy Company Ltd (Source: Google Maps). Figure 2 – Correlation between particle index and total iron with 99% confidence interval for the Coryton station. For the Coryton Power Station case study, we will examine the impact of station design, operation and chemistry on AT ORP and corrosion product on grab samples. These data can be augmented generation from the air-cooled condenser and the with online AT ORP measurements, particle moni- low pressure (LP) section of the heat recovery toring, online pH and online dissolved oxygen mea- steam generator. The LP section is part of the surements. The latter two are located after the feedwater system and is currently operated in an condensate pump discharge. AVT-R cycle chemistry environment (pH 9.4-9.6, Oxygen ingress at the seals of the condensate pump 10-30 ppb reductant). The station operates at dis- was discovered during the trial, which hindered solved oxygen levels in the range of 30-70 ppb, the establishment of a direct correlation between peaking to levels above 100 ppb during low load the on-line pH and oxygen measurements and cor- conditions when cycling. For corrosion control in rosion of the air-cooled condenser (Figure 3). the air-cooled condenser, the water chemistry parameters, most noticeably dissolved oxygen and Daily variability of ca.
Recommended publications
  • Positive Condensate Drainage from Heat Transfer Equipment Under Modulating Steam Conditions
    Understand how a good heating system design on paper can become a big problem once installed. Positive Condensate Drainage from Heat Transfer Equipment under Modulating Steam Conditions November 13, 2017 CNY Expo - Looked Good on Paper… Types of Heat Transfer Direct The heating medium is directly mixed (convection) with the substance being heated i.e. “Direct injection”. Indirect (Heat Exchange Equipment) Heat energy from the heating medium is passed to the substance being heated through a physical barrier (conduction). Steam Heat Transfer 101 1. Steam Supply 2. Heat Transfer 3. Condensate Removal Heat Exchanger Flow Heat Exchanger Sizing Q = U x A x ∆T, where U = K /(dx * Fouling Factors) Type & Thickness of Materials of Construction. Standard HX sizes: 16.3-, 25.8-, 35.2-, 44.6-, 54.0-, 63.4-, 72.9-, 82.3-, 91.7-SQFT Copper Example: 887,760 = 324 x 27.4 x 100 Copper Application requires 27.4 SQFT but the Stainless Steel closest suitable size is 35.2 SQFT. dX A Double Wall Therefore, the HX starts over-sized by 28.5%. Normal Operation Product Temperature Input P1 Heat Exchanger P1 > P2 = Heat Exchanger Dry P2 Vacuum = Negative Differential Pressure Steam occupies 1,675 times the amount of space than water. 3 ft. When steam condenses in a “Closed-System”, a vacuum is created. 3 ft. 3 ft. Conventional Condensate Removal System Pressure: Modulating vs. Constant Pressure Time Pressure Time Modulating Steam Traps Valve Head & Seat Air Vent Float Mechanism Inverted Bucket Float & Thermostatic • Continuous Steam – Good • Continuous Steam –
    [Show full text]
  • Gec Esfid Final
    Gateway Energy Centre UNDERGROUND GGAS PIPELINE AND ASSOCIATED ABOVE GROUND INSTALLATION ENVIRONMENTAAL STATEMENT FURTHER INFORMATION DOCUMENT Prepared by July 2011 CONTENTS Page LIST OF ABBREVIATIONS PREFACE 1 1 INTRODUCTION 1 1.1 Background to the ES FID 1 1.2 Relationship between the ES and ES FID 1 2 PLANNING AND ENERGY POLICY 5 2.1 Overview 5 3 GAS PIPELINE ROUTE AND AGI LOCATION SELECTION 7 3.1 Response to Thurrock Council 7 4 CONSTRUCTION METHODS AND OPERATION 9 4.1 Response to Oikos Storage Ltd (Agent: Adams Hendry) 9 5 LAND USE 10 5.1 Response to Shell (Agent: Jones Lang LeSalle) 10 6 LANDSCAPE AND VISUAL 18 6.1 Response to Thurrock Council 18 7 LAND USE / GEOLOGY, HYDROLOGY AND HYDROGEOLOGY 24 7.1 Response to Thurrock Council 24 8 CULTURAL HERITAGE 24 8.1 Response to ECC (Historic Environment Branch) 24 9 INDIRECT / SECONDARY AND CUMULATIVE IMPACTS 25 9.1 Response to Thurrock Council 25 9.2 Update to the March 2011 ES Section 18 (Indirect / Secondary and Cumulative Impacts) 27 APPENDIX A REPRESENTATIONS MADE BY THRID PARTIES TO TTGDC APPENDIX B UPDATES TO MARCH 2011 ES SECTIONS 2 AND 3 APPENDIX C UPDATE TO MARCH 2011 ES SECTION 6 APPENDIX D SUBSTITUTION OF MARCH 2011 ES SECTION 15 APPENDIX E UPDATE TO MARCH 2011 ES SECTION 18 57 GEC Underground Gas Pipeline and Associated Above Ground Installation July 2011 LIST OF ABBREVIATIONS 3LPE 3 layer polyethylene AC Alternating Current ACC Air Cooled Condenser AGI Above Ground Installation AOD Above Ordnance Datum AUT Automatic Ultrasonic Testing BAP Biodiversity Action Plan BP British
    [Show full text]
  • Cd60 Dehumidifier Specifications
    To Buy: Visit www.sylvane.com or call (800) 934-9194 For Product Support: Contact Ebac USA at (757) 873 6800 CD60 DEHUMIDIFIER SPECIFICATIONS Specifications CD60 Features CD60 Model No. 10264FR-US Model No. 10264FR-US Height 17” (432mm) On/Off Control Width 20” (514mm) Electronic Defrost Control Depth 14” (356mm) Compressor Type Rotary Weight 80 lbs (36kg) Fitted Mains Plug Voltage 110 V Free Standing Adjustable Feet Phase 1 Remote Humidistat Frequency 60 Hz Adjustable Control Humidistat Current 7 A Hot Gas Defrost System Power 880W Hours Run Meter Airflow 360cfm (608m3/hr) High Capacity Condensate Pump Noise Level 57 dba Quick Disconnect Hose Coupling Refrigerant R407c 25’ Length of PVC Drain Hose Effective Volume 8,369 cu.ft (237m3) Epoxy Powder Coating Typical Extraction 56 ppd Minimum Operating Temperature 33°F (1°C) Maximum Operating Temperature 95°F (35°C) APPLICATION The EIPL CD60 commercial / industrial dehumidifier was designed to provide energy efficient humidity control in a wide range of applications including offices, laboratories, apartments, storage areas, restaurants, bars, museums, locker rooms, computer, telecommunication rooms and basements. It is a quiet, high efficiency, high capacity unit designed to suit your HVAC needs. KEY DESIGN FEATURES • Adjustable control humidistat to maintain the level of dryness • A convenient drain point for condensate collection of hose attachment • EIP’s unique “Hot Gas” defrosting feature which automatically melts away frost buildup providing effective operation at low ambient temperatures • Rugged, epoxy powder-coated steel chassis and housing. • Hours run meter • Simplicity of installation and operation with a standard 115V plug • Extra long power cord.
    [Show full text]
  • How to Perform Mold Inspections
    ~ 1 ~ HOW TO PERFORM MOLD INSPECTIONS Mold inspection is a specialized type of inspection that goes beyond the scope of a general home inspection. The purpose of this publication is to provide accurate and useful information for performing mold inspections of residential buildings. This book covers the science, properties and causes of mold, as well as the potential hazards it presents to structures and to occupants’ health. Inspectors will learn how to inspect and test for mold both before and after remediation. This text is designed to augment the student’s knowledge in preparation for InterNACHI’s online Mold Inspection Course and Exam (www.nachi.org). This manual also provides a practical reference guide for use on-site at inspections. Authors: Benjamin Gromicko, Director of InterNACHI Online Education, and Executive Producer, NACHI.TV Nick Gromicko, Founder, International Association of Certified Home Inspectors, and Founder, International Association of Certified Indoor Air Consultants Edited by: Kate Tarasenko / Crimea River To order online, visit: www.nachi.org www.IAC2.org www.InspectorOutlet.com Copyright © 2009-2010 International Association of Certified Indoor Air Consultants, Inc. (IAC2) www.IAC2.org All rights reserved. ~ 2 ~ Mold Inspection: Table of Contents Overview…....................................................................................... 3 Section 1: Types of Mold Inspections.............................................. 5 Section 2: IAC2 Mold Inspection Standards…………………………… 9 Section 3: What is Mold? …………………………………………………
    [Show full text]
  • Condensate Pump
    Condensate Pump Installation and Safety Instructions CP-NL20 CP-NL20-230 CP-NL20 CP-NL20-230 Rated 120 Volts / 60 Hz 220 Volts / 60 Hz Voltage (208-230) Rated 1.9 Amps 1.0 Amps Current Draw Input USA 3-prong plug NEMA 6-15 plug Type Head 20 . maximum 20 . maximum Height Flow Rate 1.6 GPM 1.6 GPM at Zero Head Temperature • Continuous duty 140F° • Continuous duty 140F° Rating • Max inlet temperature 160F° • Max inlet temperature 160F° • Not suitable for contact with • Not suitable for contact with steam or gasses that steam or gasses that exceed 160F° exceed 160F° Product Dimensions 11.8” x 5.9“ x 6.7” 11.8” x 5.9“ x 6.7” (LxWxH) Product 5 lbs. 5 lbs. Weight Inlet Height 4.4” (1.75” low prole) 4.4” (1.75” low prole) from Base Included • Instruction Sheet • Instruction Sheet Accessories • Stainless Steel Hang Tabs • Stainless Steel Hang Tabs • Plug Protector • Plug Protector • 4’ Remote Shuto Leads • 4’ Remote Shuto Leads with Insulated Terminals with Insulated Terminals • Polyethelene Inlet Covers (3) • Polyethelene Inlet Covers (3) Wiring Color Black - Live/Hot Brown - Live/Hot References White - Neutral Blue - Live/Hot Green - Ground Green/Yellow - Ground All installations must conform All installations must conform to NEC requirements to NEC requirements SAFETY WARNING FOLLOW ALL SAFETY INFORMATION TO REDUCE POTENTIAL ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. PUMP MUST BE PROPERLY GROUNDED. NEVER USE THE PUMP TO MOVE FLAMMABLE LIQUIDS. NEVER USE THE PUMP IN AN EXPLOSIVE GAS ENVIRONMENT, OR WHERE GAS FUMES OR VAPOR MAY BE PRESENT.
    [Show full text]
  • Installation Instructions, Model 519: 60 Hz FM3081 155408
    NOTICE TO INSTALLER: Instructions must remain with installation. FM3081 0318 Supersedes New Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347 SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961 Visit our web site: TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624 zoellerpumps.com Register your Zoeller Pump Company Product on our website: INSTALLATION INSTRUCTIONS http://reg.zoellerpumps.com/ MODEL 519 Condensate Pump 1. Inspect all materials. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using. 2. Carefully read all the literature provided to familiarize yourself with specific details regarding installation and use before attempting the installation. These materials should be retained for future reference. SEE BELOW FOR LIST OF WARNINGS 1. To help reduce the risk of electrical shock, a properly grounded 4. TESTING FOR GROUND. As a safety measure, each electrical receptacle or control box of grounding type must be installed and outlet should be checked for ground using an Underwriters P/N 155408 protected by a ground fault circuit interrupter (GFCI) in accordance Laboratory Listed circuit analyzer which will indicate if the power, with the National Electrical Code and applicable local codes. If neutral and ground wires are correctly connected to your outlet. pump is wired direct, a GFCI must be installed in the control box. If they are not, call a qualified licensed electrician. (SEE WARNING BELOW) 5. Installation and checking of electrical circuits and hardware should 2.
    [Show full text]
  • IW-25 Dehumidifier Installation & Operations Manual
    IW-25 Dehumidifier Installation and Operation Manual Installation & Operations InstallationIW and-25 Operation-1 Dehumidifier Manual Manual IW-25-1 Dehumidifier Please Read and Save These Instructions Please ReadPlease Readand and Save Save These These Instructions Instructions InnovativeInnov Dehumidifierative Dehumidifier Systems, LLC Systems, LLC Innovative6260 Dehumidifier Ocean6260 Highway Ocean 17 HighwaySystems, West 17 West LLC Ocean Isle Beach, NC 28469 6260 OceanOcean Highway Isle Beach, 17 West NC 28469 910-579-DEHU910-579-DEHU Ocean Isle910 Beach,-579-3348910 NC-579 28469-3348 www.innovativedehu.comwww.innovativedehu.com 910-579-DEHU 1 910-579-33481 www.innovativedehumidifer.com Table of Contents Safety Notes 2 Identification 3 Electrical Supply 3 Principle of Operation 3 Installation 4 Operating Instructions 4 Diagram 5 Maintenance 6 Troubleshooting 8 Warranty Information 9 1 Safety Notes • The IW-25 Dehumidifier must always be connected using a grounded electrical connec- tion (as required for all electrical appliances). If non-grounded wiring is used, all liability re- verts to owner and the warranty is voided. • The IW-25 Dehumidifier should only be installed and serviced by a qualified technician. • If there is a chance that water flooded the dehumidifier, it should be opened and allowed to dry thoroughly before reconnecting to electrical power and restarting. • To ensure proper operation, no obstruction should be located within 36” of the discharge of the unit. • Do not insert any objects or fingers into the inlet or discharge. If service is required, call a qualified technician. • All work on the dehumidifier should be done with the unit “off” and unplugged or the breaker turned off.
    [Show full text]
  • Gas Transmission
    Gas Transmission Our Performance: 2019/2020 National Grid Gas plc 30 September 2020 National Grid Gas Transmission Our Performance for 2019/20 Table of Contents I. Strategic Performance Overview (SPO) for 2019/20 ............................................... 2 II. Operational Context ................................................................................................. 17 III. Outputs ...................................................................................................................... 20 IV. Outputs – Safety ....................................................................................................... 21 V. Outputs – Reliability and Availability ..................................................................... 24 VI. Outputs – Environment ............................................................................................ 34 VII. Outputs – Customer Satisfaction ............................................................................ 40 VIII. Outputs – Customer Connections .......................................................................... 43 IX. Totex (TO and SO) .................................................................................................... 47 X. Load Related Capital Expenditure (TO) .................................................................. 51 XI. Non Load Related Capital Expenditure (TO) .......................................................... 54 XII. Non Operational Capital Expenditure (TO) .........................................................
    [Show full text]
  • Quick Start Guide
    The Watchdog900 Quick Start Guide Seaira Global • 14021 NC Highway 50 • Surf City, NC 28445 www.seairaglobal.com WatchDog 900 Quick Start Guide • Prepare Crawl Space for Installation • Tips for Dehumidifier Installation • Operating Instructions • Benefits of a Dehumidifier • Common Terms • Parts Diagram • Trouble Shooting • Submit Warranty • Additional Resources While you’re waiting for your new dehumidifier to arrive, here are a few topics to keep in mind. How to Prepare Your Crawl Space for Installation If you decide to install your dehumidifier in a crawl space, there are a few steps you need to take prior to installation. 1. First, you will need clean out any debris that may be cluttering up the crawl space. This will make sure that there are no hidden problems such as cracks in the foundation. It will also ensure that the vapor barrier can be installed properly. In addition, cleaning out any unnecessary items will make it much easier to move around in the crawl space. Being able to move around more easily is useful for a hassle free installation, as well as for future maintenance that may need to be done. 2. After the crawl space is clear, you will need to inspect it for any potential issues so they can be fixed prior to installation. For instance, you may notice signs of pests or rodents in the crawl space. The crawl space could also show signs of structural issues, such as damaged floor joists or girders. Most importantly, you need to ensure that all signs of excess moisture are taken care of.
    [Show full text]
  • Condensate Pumps
    ® Condensate Pumps Condensate pumps are found in a number of applications and are used Safety Switch – to collect and then move excess condensate to a suitable drain location. A safety switch is optional on some pumps and is connected to the float The majority of condensate pumps are installed in residential and in the pump reservoir. Should the pump fail or clog the higher than commercial properties or used in restaurant applications. (With Mini-Split normal condensate level in the pump reservoir will actuate the safety applications starting to gain acceptance in the North American market, switch. The safety switch is typically wired into the low voltage control look for a future MARS Tech to learn about condensate pumps for those system of a HVAC unit and will turn the system off until the issue with specialized applications.) the pump is corrected. This reduces the possibility of water damage for Some of the more common applications for condensate the property owner. pumps; Float – • Central Air-conditioning • Whole House Humidifiers The most reliable floats are made of solid plastic. Some floats that have • Condensing Gas Furnace • Mini-Split Units been used are a porous foam material which can degrade and collect • Ice Machines • Refrigeration organic matter. Once this happens the float is no longer a float. • Beverage Machines • Condensing Gas Boilers The best design for a solid plastic float is to have a stand-off molded • Drinking Fountains into the bottom of the housing so the float will not stick to any debris in The most common condensate pumps fall into the following the bottom of the reservoir.
    [Show full text]
  • BGS Report, Single Column Layout
    INDUSTRIAL CARBON DIOXIDE EMISSIONS AND CARBON DIOXIDE STORAGE POTENTIAL IN THE UK Report No. COAL R308 DTI/Pub URN 06/2027 October 2006 Contractor British Geological Survey Keyworth Nottingham NG12 5GG United Kingdom Tel: +44 (0)115 936 3100 By S. Holloway C.J. Vincent K.L. Kirk The work described in this report was carried out under contract as part of the DTI Carbon Abatement Technologies Programme. The DTI programme is managed by Future Energy Solutions. The views and judgements expressed in this report are those of the contractor and do not necessarily reflect those of the DTI or Future Energy Solutions First published 2006 © DTI 2006 Foreword This report is the product of a study by the British Geological Survey (BGS) undertaken for AEA Technology plc as part of agreement C/07/00384/00/00. It considers the UK emissions of carbon dioxide from large industrial point sources such as power stations and the potential geological storage capacity to safely and securely store these emissions. Acknowledgements The authors would like to thank the UK DTI for funding the work, and Dr Erik Lindeberg of Sintef Petroleum Research for provision of a programme to calculate the density of CO2. Contents Foreword.........................................................................................................................................i Acknowledgements.........................................................................................................................i Contents...........................................................................................................................................i
    [Show full text]
  • Boiler Pump Condensate Pump
    TECHNICAL DATA SHEET Boiler Pump Product BP-46 and BP-46-230 Condensate Pump Application High Temperature/High Performance Condensate Pump Purpose The DiversiTech Boiler Pump is designed to automatically remove the water produced by condensing furnace and boilers that produce high temperature condensate. Can also be used for air conditioning evaporation coils, especially when high li is required. These pumps can also be used for other types of fresh water removal from refrigeration equipment, dehumidiers, water dispensers, etc. where gravity drainage is impossible. Advantages With a 1 gallon tank, this pump is constructed from a heat resistant plastic and can handle water temperatures up to 212˚F. This pump incorporates thermal overload protection and a indepen- dent high level alarm switch / boiler interlock. The check valve to prevent condensate owing back into the pump and odours from drain pipes. Features • Suitable for condensate up to 212°F • Independent high-level safety switch • Maximum ow 204 gal/hr • Maximum head 46’ • Withstands acidic condensate down to 2.8ph Maximum Condensate • Suitable for condensate up to 212°F Temperature Rated Voltage • BP-46 : 115VAC 60Hz • BP-46-230 : 230VAC 60Hz Alarm Contact Ratings • 240VAC 3A Dry Contact Input Type • USA 3-Prong molded plug (120VAC) • NEMA 6-15 plug (230VAC) Maximum Li Height • 46’ Vertical Li Flow Rate @ Zero Head • BP-46 & BP-46-230 : 204 gal/hr Dimensions • BP-46: L:12.8” x W:6.3” x H:9.8” Discharge Line • 3/8” Tank Capacity • BP-46: 1 Gallon Included Accessories • Installed Independent High Level Safety Switch Warranty • 2 Years Height Inlet Height Inlet Size Length Width Weight Cable Length 9.8 in 4.5 in 1.2 in 12.8 in 6.3 in 6.8 lbs 5.9 Reserve Model Tank Drink On O Capacity Before Alarm Level Cycle Level Level Overow BP-46 1 gal 0.39 gal 2.24 in 0.75 in 0.18 gal 4.2 in BP-46 - 230 PRV Discharge should be routed through tundish before entering the pump.
    [Show full text]