Table of Contents

Total Page:16

File Type:pdf, Size:1020Kb

Table of Contents Table of Contents Chapter 1 Bus Decode -------------------------------------------------------------- 1 Basic operation --------------------------------------------------------------------------------------------- 1 Add a Bus Decode ----------------------------------------------------------------------------------------------------- 1 Advance channel setting ---------------------------------------------------------------------------------------------- 2 Specially Bus Decode: ------------------------------------------------------------------------------------------------ 4 1-Wire ------------------------------------------------------------------------------------------------------------------- 7 3-Wire ------------------------------------------------------------------------------------------------------------------- 9 7-Segment -------------------------------------------------------------------------------------------------------------- 11 A/D Converter--------------------------------------------------------------------------------------------------------- 14 AcceleroMeter -------------------------------------------------------------------------------------------------------- 17 AD-Mux Flash -------------------------------------------------------------------------------------------------------- 19 Advanced Platform Management Link (APML) ---------------------------------------------------------------- 21 BiSS-C------------------------------------------------------------------------------------------------------------------ 23 BSD --------------------------------------------------------------------------------------------------------------------- 25 CAN 2.0B/ CAN FD ------------------------------------------------------------------------------------------------- 27 Closed Caption -------------------------------------------------------------------------------------------------------- 29 DALI -------------------------------------------------------------------------------------------------------------------- 31 DMX512 --------------------------------------------------------------------------------------------------------------- 33 Display Port Auxiliary Channel (DP Aux Ch) ------------------------------------------------------------------- 35 Enhanced Serial Peripheral Interface (eSPI) --------------------------------------------------------------------- 37 FlexRay----------------------------------------------------------------------------------------------------------------- 40 HD Audio -------------------------------------------------------------------------------------------------------------- 43 HDLC ------------------------------------------------------------------------------------------------------------------- 45 HDQ -------------------------------------------------------------------------------------------------------------------- 47 2 HID Over I C ---------------------------------------------------------------------------------------------------------- 49 Acute Technology Inc. i Copyright 2020 2 I C ----------------------------------------------------------------------------------------------------------------------- 51 I3C ---------------------------------------------------------------------------------------------------------------------- 53 2 I S ----------------------------------------------------------------------------------------------------------------------- 57 I80 ----------------------------------------------------------------------------------------------------------------------- 59 IDE ---------------------------------------------------------------------------------------------------------------------- 61 IrDA -------------------------------------------------------------------------------------------------------------------- 65 ITU656 (CCIR656)--------------------------------------------------------------------------------------------------- 67 JTAG ------------------------------------------------------------------------------------------------------------------- 69 LCD1602 --------------------------------------------------------------------------------------------------------------- 73 LED_Ctrl --------------------------------------------------------------------------------------------------------------- 75 LIN ---------------------------------------------------------------------------------------------------------------------- 77 Line Decoding--------------------------------------------------------------------------------------------------------- 79 Line Encoding --------------------------------------------------------------------------------------------------------- 83 Low Pin Count (LPC) ------------------------------------------------------------------------------------------------ 89 Line Printer Terminal Port (LPT) ---------------------------------------------------------------------------------- 91 M-Bus ------------------------------------------------------------------------------------------------------------------ 93 Math -------------------------------------------------------------------------------------------------------------------- 95 Mobile Display Digital Interface (MDDI)------------------------------------------------------------------------ 97 MDIO ------------------------------------------------------------------------------------------------------------------- 99 MHL-CBUS --------------------------------------------------------------------------------------------------------- 101 MII/RMII ------------------------------------------------------------------------------------------------------------ 103 Microwire ------------------------------------------------------------------------------------------------------------ 106 MIPI DSI ------------------------------------------------------------------------------------------------------------- 108 MIPI RFFE ---------------------------------------------------------------------------------------------------------- 110 MIPI SPMI ---------------------------------------------------------------------------------------------------------- 111 MMC ----------------------------------------------------------------------------------------------------------------- 113 Acute Technology Inc. ii Copyright 2020 ModBus -------------------------------------------------------------------------------------------------------------- 116 NAND Flash --------------------------------------------------------------------------------------------------------- 118 NEC IR --------------------------------------------------------------------------------------------------------------- 124 PECI ------------------------------------------------------------------------------------------------------------------ 126 PMBus ---------------------------------------------------------------------------------------------------------------- 128 ProfiBus -------------------------------------------------------------------------------------------------------------- 130 PS/2 ------------------------------------------------------------------------------------------------------------------- 132 PWM ------------------------------------------------------------------------------------------------------------------ 134 QI ---------------------------------------------------------------------------------------------------------------------- 138 RC-5 ------------------------------------------------------------------------------------------------------------------ 140 RC-6 ------------------------------------------------------------------------------------------------------------------ 142 RGB Interface ------------------------------------------------------------------------------------------------------- 144 S/PDIF ---------------------------------------------------------------------------------------------------------------- 146 SDIO ------------------------------------------------------------------------------------------------------------------ 149 Serial Flash ---------------------------------------------------------------------------------------------------------- 152 Serial IRQ ------------------------------------------------------------------------------------------------------------ 158 Serial General Purpose Input Output (SGPIO) ---------------------------------------------------------------- 162 Smart Card (ISO7816) --------------------------------------------------------------------------------------------- 164 System Management Bus (SMBus) ----------------------------------------------------------------------------- 166 Serial Microprocessor Interface (SMI) -------------------------------------------------------------------------- 169 Serial Peripheral Interface (SPI) --------------------------------------------------------------------------------- 171 Serial Peripheral Interface NAND (SPI NAND) -------------------------------------------------------------- 178 SSI--------------------------------------------------------------------------------------------------------------------- 180 ST7669 --------------------------------------------------------------------------------------------------------------- 182 Serial VID (SVID) (Upon Request) ----------------------------------------------------------------------------- 184 Serial Wire Debug (SWD) ---------------------------------------------------------------------------------------- 186 Acute Technology Inc. iii Copyright 2020 SWP -------------------------------------------------------------------------------------------------------------------
Recommended publications
  • Humidity & Temperature Sensor
    Humidity & Temperature Sensor AM2322 Product Manuals product Features Super Mini Size Easy Protable Ultra-Low Power State Ultra-low voltage work Excellent long-term stability StandardI2C And single bus output 一、 Product Overview AM2322 The digital temperature and humidity sensor is a kind of temperature and humidity composite sensor with the output of calibrated digitalsignal.The special temperature and humidity collection technology is adopted to ensure the high reliability and long-term stability of the product.The sensor includes a capacitive sensing element and a high-precision integrated temperature measurement element, which is connected to a high- performance microprocessor.The product has high quality, super fast response, strong anti-interference ability and high cost performance. AM2322 communication mode adopts single bus, standard I squared C communication mode.Standard single bus interface makes system integration easy and fast.The super small volume, extremely low power consumption, the signal transmission distance can reach up to 20 meters, making it the best choice for all kinds of Two kinds of communication mode is used directly output after applications and even the most demanding applications.The I temperature compensation, humidity, temperature and the CRC squared C communication mode adopts standard communication check and other digital information, users need to secondary timing, and the user can be directly attached to the I squared C calculation of digital output, also need not to compensate the communication bus, with no additional wiring and simple use. temperature humidity, accurate temperature and humidity information can be got.The two modes of communication are free to switch, users are free to choose, easy to use, and should be widely used.The product is 4 lead wire and convenient connection.
    [Show full text]
  • Modbus TCP Master (OPC) User's Manual
    Station Automation COM600 3.4 Modbus TCP Master (OPC) User's Manual 1MRS756445 Station Automation COM600 3.4 Issued: 21.12.2007 Version: D/06.11.2009 Modbus TCP Master (OPC) User's Manual Contents: 1. About this manual .................................................................................. 7 1.1. Copyrights ...................................................................................... 7 1.2. Trademarks .................................................................................... 7 1.3. General .......................................................................................... 7 1.4. Document conventions .................................................................. 8 1.5. Use of symbols .............................................................................. 9 1.6. Terminology .................................................................................... 9 1.7. Abbreviations ............................................................................... 11 1.8. Related documents ...................................................................... 12 1.9. Document revisions ..................................................................... 12 2. Introduction ........................................................................................... 13 2.1. Functional overview ..................................................................... 13 2.2. Modbus OPC Server features ...................................................... 14 3. Configuration .......................................................................................
    [Show full text]
  • Modbus Instruction Manual For
    Instruction manual Modbus slave interface for digital Mass Flow / Pressure instruments Doc. no.: 9.17.035AC Date: 28-07-2021 ATTENTION Please read this instruction manual carefully before installing and operating the instrument. Not following the guidelines could result in personal injury and/or damage to the equipment. BRONKHORST® Disclaimer The information in this manual has been reviewed and is believed to be wholly reliable. No responsibility, however, is assumed for inaccuracies. The material in this manual is for information purposes only. Copyright All rights reserved. This documentation is protected by copyright. Subject to technical and optical changes as well as printing errors. The information contained in this document is subject to change at any time without prior notification. Bronkhorst High-Tech B.V. reserves the right to modify or improve its products and modify the contents without being obliged to inform any particular persons or organizations. The device specifications and the contents of the package may deviate from what is stated in this document. Symbols Important information. Discarding this information could cause injuries to people or damage to the Instrument or installation. Helpful information. This information will facilitate the use of this instrument. Additional info available on the internet or from your local sales representative. Warranty Bronkhorst® products are warranted against defects in material and workmanship for a period of three years from the date of shipment, provided they are used in accordance with the ordering specifications and the instructions in this manual and that they are not subjected to abuse, physical damage or contamination. Products that do not operate properly during this period may be repaired or replaced at no charge.
    [Show full text]
  • Benefits of a Standardized Diagnostic Framework
    Benefits of a standardized diagnostic framework Hareesh Prakash Development Engineer The copying, distribution and utilization of this document as well as the communication of its contents to other without expressed authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or ornamental design registration. Agenda DiagnosticsDiagnostics withwith standardsstandards –– Motivation Motivation ODXODX –– ODXplorer ODXplorer MCD-3MCD-3 ServerServer –– samMCD3 samMCD3 serverserver MVCI-D-PDU-APIMVCI-D-PDU-API –– HSX HSX samtecsamtec DiagnosticDiagnostic FrameworkFramework The copying, distribution and utilization of this document as well as the communication of its contents to other without expressed authorization is prohibited. ffenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or ornamental design registration. Diagnostics with Standards Motivation 2000 - 2009 New ACC Stop & Go ALC + Navigation Strategies, Heading Control Night Vision Process, AFS I + II X-AGS 1990 - 1999 Internet Tools, … Telematics Navigation system Online Services CD-Changer Bluetooth Bus system Car Office ACC Adaptive Cruise Control Complexity Local Hazard Warning Complexity 1980 - 1989 Airbags Integrated Safety Systems DSC Dynamic Stability Control Electronic Transmission control Break-By-Wire Adaptive Transmission Control Electronic air conditioning control Steer-By-Wire Anti-roll ASR i-Drive Xenon Lights ABS Fuel cells 1970 - 1979 BMW Assist Telephone LH RDS/TMC 2 Electronic Fuel Injection Seat heating Lane change ssistant Emergency calls Electronic Ignition … Personalization Servotronic Check Control Software Update … Idle speed regulator Force Feedback Pedal Central lock … Costs Source: [2] Hudi; [4] Reichert The copying, distribution and utilization of this document as well as the communication of its contents to other without expressed authorization is prohibited.
    [Show full text]
  • Smartwire-DT Gateways – Canopen and PROFIBUS-DP
    09/11 MN05013002Z-EN Manual replaces 06/09 AWB2723-1612en SmartWire-DT Gateways All brand and product names are trademarks or registered trademarks of the owner concerned. Emergency On Call Service Please call your local representative: http://www.eaton.com/moeller/aftersales or Hotline of the After Sales Service: +49 (0) 180 5 223822 (de, en) [email protected] Original Operating Instructions The German-language edition of this document is the original operating manual. Translation of the original operating manual ) All editions of this document other than those in German language are translations of 2 the original German manual. 1st edition 2009, edition date 02/09 2nd edition 2009, edition date 06/09 3rd edition 2010, edition date 03/10 4th edition 2010, edition date 06/10 5th edition 2011, edition date 03/11 6th edition 2011, edition date 09/11 See revision protocol in the “About this manual“ chapter © 2009 by Eaton Industries GmbH, 53105 Bonn Production: René Wiegand Translation: globaldocs GmbH All rights reserved, including those of the translation. Rückenbreite festlegen! (1 Blatt = 0,106 mm, gilt nur für XBS) g/m 80 bei Digitaldruck Eberwein für mm = 0,080 Blatt (1 No part of this manual may be reproduced in any form (printed, photocopy, microfilm or any other process) or processed, duplicated or distributed by means of electronic systems without written permission of Eaton Industries GmbH, Bonn. Subject to alteration without notice. Danger! Dangerous electrical voltage! Before commencing the installation • Disconnect the power supply of the • Suitable safety hardware and device. software measures should be • Ensure that devices cannot be implemented for the I/O interface accidentally restarted.
    [Show full text]
  • MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1B3
    MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1b3 CONTENTS 1 Introduction ...................................................................................................................... 2 1.1 Scope of this document ........................................................................................... 2 2 Abbreviations ................................................................................................................... 2 3 Context ............................................................................................................................. 3 4 General description .......................................................................................................... 3 4.1 Protocol description ................................................................................................. 3 4.2 Data Encoding ......................................................................................................... 5 4.3 MODBUS Data model .............................................................................................. 6 4.4 MODBUS Addressing model .................................................................................... 7 4.5 Define MODBUS Transaction .................................................................................. 8 5 Function Code Categories .............................................................................................. 10 5.1 Public Function Code Definition ............................................................................. 11
    [Show full text]
  • — PROFIBUS-Adapter
    — ABB MEASUREMENT & ANALYTICS | DATA SHEET PROFIBUS-Adapter — To find your local ABB contact visit: www.abb.com/contacts For more information visit: www.abb.com/measurement — We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB. © ABB 2019 3KXN631121R1001 10/63-6.31-EN Rev. G 05.2019 2 NDA121-NO PROFIBUS-ADAPTER | 10/63-6.31-EN REV. G NDA121-NO PROFIBUS-ADAPTER | 10/63-6.31-EN REV. G 7 — Measurement made easy — Profibus DP / PC Adapter • USB NDA121-NO PROFIBUS-ADAPTER | 10/63-6.31-EN REV. G 3 — NDA121-NO PROFIBUS DP / PC-USB adapter hange from one to two columns Adapter CommDTM Desktop PC’s as well as notebooks can be flexible connected The Device Type Manager CommDTM provides access to the in the field to a PROFIBUS® network via the adapter PROFIBUS® Master NDA121-NO. Within the FDT architecture, NDA121-NO. Thereby a parallel operation of up to 16 adapter the CommunicationDTM enables DeviceDTMs to connect to is possible. The adapter supports the Master functionality of their respective devices via PROFIBUS® DP/-V1. the PROFIBUS® Standards DP (class 1 and 2), DP-V1 (class 2).
    [Show full text]
  • Tms320f28004x Microcontrollers Datasheet (Rev. F)
    TMS320F280049, TMS320F280049C, TMS320F280048, TMS320F280048C, TMS320F280045, TMS320F280049, TMS320F280049C,TMS320F280041, TMS320F280041C, TMS320F280048, TMS320F280048C,TMS320F280040, TMS320F280040C TMS320F280045, www.ti.com TMS320F280041, TMS320F280041C,SPRS945F –TMS320F280040, JANUARY 2017 – REVISED TMS320F280040C FEBRUARY 2021 SPRS945F – JANUARY 2017 – REVISED FEBRUARY 2021 TMS320F28004x Microcontrollers 1 Features – Embedded Real-time Analysis and Diagnostic (ERAD) • TMS320C28x 32-bit CPU • Communications peripherals – 100 MHz – One Power-Management Bus (PMBus) – IEEE 754 single-precision Floating-Point Unit interface (FPU) – One Inter-integrated Circuit (I2C) interface – Trigonometric Math Unit (TMU) (pin-bootable) • 3×-cycle to 4×-cycle improvement for – Two Controller Area Network (CAN) bus ports common trigonometric functions versus (pin-bootable) software libraries – Two Serial Peripheral Interface (SPI) ports • 13-cycle Park transform (pin-bootable) – Viterbi/Complex Math Unit (VCU-I) – Two Serial Communication Interfaces (SCIs) – Ten hardware breakpoints (with ERAD) (pin-bootable) • Programmable Control Law Accelerator (CLA) – One Local Interconnect Network (LIN) – 100 MHz – One Fast Serial Interface (FSI) with a – IEEE 754 single-precision floating-point transmitter and receiver instructions • Analog system – Executes code independently of main CPU – Three 3.45-MSPS, 12-bit Analog-to-Digital • On-chip memory Converters (ADCs) – 256KB (128KW) of flash (ECC-protected) • Up to 21 external channels across two independent banks
    [Show full text]
  • CP2725AC54TE Compact Power Line High Efficiency Rectifier 100-120/200-277VAC Input; Default Outputs: ±54VDC @ 2725W, 5VDC @ 4W
    GE Data Sheet CP2725AC54TE Compact Power Line High Efficiency Rectifier 100-120/200-277VAC input; Default Outputs: ±54VDC @ 2725W, 5VDC @ 4W RoHS Compliant Features • Efficiency 96.2% • Compact 1RU form factor with 30 W/in3 density • Constant power from 52 – 58VDC • 2725W from nominal 200 – 277VAC • 1200W from nominal 100 – 120VAC • Output voltage programmable from 42V – 58VDC • PMBus compliant dual I2C and RS485 serial busses • Isolated +5V Aux, signals and I2C communications • Power factor correction (meets EN/IEC 61000-3-2 and EN 60555-2 requirements) Applications • Output overvoltage and overload protection • 48VDC distributed power architectures • AC Input overvoltage and undervoltage protection • Routers/Switches • Over-temperature warning and protection • VoIP/Soft Switches • Redundant, parallel operation with active load sharing • LAN/WAN/MAN applications • Remote ON/OFF • File servers • Internally controlled Variable-speed fan • Indoor wireless • Hot insertion/removal (hot plug) • Telecommunications equipment • Four front panel LED indicators • Enterprise Networks • UL* Recognized to UL60950-1, CAN/ CSA† C22.2 No. • SAN/NAS/iSCSI applications 60950-1, and VDE‡ 0805-1 Licensed to IEC60950-1 § • CE mark meets 2006/95/EC directive • RoHS Directive 2011/65/EU and amended Directive (EU) 2015/863 Description • Conformally coated option The CP2725AC54TE Rectifier provides significant efficiency improvements in the Compact Power Line platform of Rectifiers. High- density front-to-back airflow is designed for minimal space utilization and is highly expandable for future growth. The wide-input standard product is designed to be deployed internationally. It is configured with both RS485 and dual-redundant I2C communications busses that allow it to be used in a broad range of applications.
    [Show full text]
  • Master Simulators
    Master simulators By using master simulators from HMS, you can set up and test slaves/adapters on PROFIBUS, PROFINET, CANopen, EtherNet/IP and DeviceNet without having a PLC in place. Simply connect to your computer and you have a very cost-efficient alternative to a PLC or PC-card. CANopen interface — powered by USB USB port on the PC RS-232 CANopen cable 9-pin D-Sub connector PROFIBUS interface Device under test Device under test DeviceNet interface USB (24V power supply required to connect and test a DeviceNet adapter —not included). DeviceNet cable with data and power lines Pluggable screw connector Ethernet cable with termination Device under test Device under test Available for: Test your device without an expensive PLC Key features Master simulators are ideal for test-wiring of inputs and ouputs • Easy-to-use test and diagnostics and reading and writing analog values. They are useful during tool. setup of slave/adapters in a network as well as during final • No programming required. inspection tests at the device manufacturer. • Auto-detects slaves/adapters Industrial Ethernet versions are software-only, while fieldbus (even when GSD/EDS file is not versions also include a converter interface which is used to available). connect the fieldbus cable to the PC. • Auto detection of I/O data size. No GSD/EDS files needed (not for EtherNet/IP) During setup and maintenance, there may not be GSD/EDS available making master simulators especially useful for this scenario. HMS provides a full 3 year product guarantee TECHNICAL SPECIFICATIONS Description Consists of a Windows-based Software only.
    [Show full text]
  • Efficiently Triggering, Debugging and Decoding Low-Speed Serial Buses
    Efficiently Triggering, Debugging and Decoding Low-Speed Serial Buses Hello, my name is Jerry Mark, I am a Product Marketing Engineer at Tektronix. The following presentation discusses aspects of embedded design techniques for “Efficiently Triggering, Debugging, and Decoding Low-Speed Serial Buses”. 1 Agenda Introduction – Parallel Interconnects – Transition from Parallel to Serial Buses – High-Speed versus Low-Speed Serial Data Buses Low-Speed Serial Data Buses – Challenges – Technology Reviews – Measurement Solutions Summary 2 In this presentation we will begin by taking a glance at the transition from parallel-to-serial data and the challenges this presents to engineers. Then we will briefly review some of the most widely used low-speed serial buses in industry today and some of their key characteristics. We will turn our attention to the key measurements on these buses. Subsequently, we will present by example how the low-speed serial solution from Tektronix addresses these challenges. 2 Parallel Interconnects Traditional way to connect digital devices used parallel buses Advantages – Simple point-to-point connections – All signals are transmitted in parallel, simultaneously – Easy to capture state of bus (if you have enough channels!) – Decoding the bus is relatively easy Disadvantages – Occupies a lot of circuit board space – All high-speed connections must be the same length – Many connections limit reliability – Connectors may be very large 3 Parallel buses present all of the bits in parallel, as shown in the logic analyzer display. A parallel connection between two ICs can be as simple as point-to-point circuit board traces for each of the data lines. If you can physically probe these lines, it is easy to display the bus state on a logic analyzer or mixed signal oscilloscope.
    [Show full text]
  • Modbus Signal Output Adapter Quick Start Guide
    TM Modbus Signal Output Adapter Quick Start Guide Mini USB Connector Adapter Used to configure adapter settings, provide power to the adapter, and passthrough Overview: communication to the attached sonde. See page 4 for USB passthrough info. Supply Power, 12VDC Provided from external regulated power source (not included). Delivering quality data Modbus I/O Terminal Use either 485 (default) Status LED where and when you or RS-232 terminals. See page 2 for need it most. status indications. Introduction: The 599825 is a communication adapter Safety: for the EXO multiparameter sonde platform. It converts the proprietary Refer to EXO system signal from the water quality sonde into manual for complete safety a Modbus protocol over either RS-232 documentation associated with or RS-485 signals. The adapter simplifies the EXO system. (Available at integration into 3rd party SCADA systems, EXOwater.com) and also features a USB port that Follow all applicable code and supports passthrough communication Magnetic Read Switch directly to the connected sonde. This regulations subject to electrical Used to rediscover feature allows configuration, calibration, wiring and operation of attached sonde. and data transfer without having to the system. disconnect the field cabling. Specifications What’s Included: You’ll also need: Supply Voltage: 9 - 16 VDC or USB 5 VDC Your new 599825 EXO Communication • Flat blade screwdriver for Current Draw Adapter: Adapter comes with: terminal blocks ~20mA typical (@12VDC) • (1) Modbus Adapter • Phillip’s screwdriver
    [Show full text]