bioRxiv preprint doi: https://doi.org/10.1101/2020.04.21.044982; this version posted April 23, 2020. The copyright holder for this preprint (which was not certified by peer review) is the author/funder. All rights reserved. No reuse allowed without permission. Determining the Depth Limit of Bioluminescent Sources in Scattering Media. Ankit Raghuram1,*, Fan Ye1, Jesse K. Adams1,2, Nathan Shaner3, Jacob T. Robinson1,2,4,5, Ashok Veeraraghavan1,2,6 1 Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, USA 2 Applied Physics Program, Rice University, Houston, TX 77005, USA 3 Department of Neurosciences, University of California San Diego, La Jolla, CA 92093, USA 4 Department of Neuroscience, Baylor College of Medicine, Houston, TX 77030, USA 5 Department of Bioengineering, Rice University, Houston, TX 77005, USA 6 Department of Computer Science, Rice University, Houston TX 77005, USA *
[email protected] Abstract Bioluminescence has several potential advantages compared to fluorescence microscopy for in vivo biological imaging. Because bioluminescence does not require excitation light, imaging can be performed for extended periods of time without phototoxicity or photobleaching, and optical systems can be smaller, simpler, and lighter. Eliminating the need for excitation light may also affect how deeply one can image in scattering biological tissue, but the imaging depth limits for bioluminescence have yet to be reported. Here, we perform a theoretical study of the depth limits of bioluminescence microscopy and find that cellular resolution imaging should be possible at a depth of 5-10 mean free paths (MFPs). This limit is deeper than the depth limit for confocal microscopy and slightly lower than the imaging limit expected for two-photon microscopy under similar conditions.