Working Load to Break Load: Safety Factors in Composite Yacht Structures
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Chapter 6 Structural Reliability
MIL-HDBK-17-3E, Working Draft CHAPTER 6 STRUCTURAL RELIABILITY Page 6.1 INTRODUCTION ....................................................................................................................... 2 6.2 FACTORS AFFECTING STRUCTURAL RELIABILITY............................................................. 2 6.2.1 Static strength.................................................................................................................... 2 6.2.2 Environmental effects ........................................................................................................ 3 6.2.3 Fatigue............................................................................................................................... 3 6.2.4 Damage tolerance ............................................................................................................. 4 6.3 RELIABILITY ENGINEERING ................................................................................................... 4 6.4 RELIABILITY DESIGN CONSIDERATIONS ............................................................................. 5 6.5 RELIABILITY ASSESSMENT AND DESIGN............................................................................. 6 6.5.1 Background........................................................................................................................ 6 6.5.2 Deterministic vs. Probabilistic Design Approach ............................................................... 7 6.5.3 Probabilistic Design Methodology..................................................................................... -
Design for Cyclic Loading, Soderberg, Goodman and Modified Goodman's Equation
Design for Cyclic Loading 1. Completely reversing cyclic stress and endurance strength A purely reversing or cyclic stress means when the stress alternates between equal positive and Pure cyclic stress negative peak stresses sinusoidally during each 300 cycle of operation, as shown. In this diagram the stress varies with time between +250 MPa 200 to -250MPa. This kind of cyclic stress is 100 developed in many rotating machine parts that 0 are carrying a constant bending load. -100 When a part is subjected cyclic stress, Stress (MPa) also known as range or reversing stress (Sr), it -200 has been observed that the failure of the part -300 occurs after a number of stress reversals (N) time even it the magnitude of Sr is below the material’s yield strength. Generally, higher the value of Sr, lesser N is needed for failure. No. of Cyclic stress stress (Sr) reversals for failure (N) psi 1000 81000 2000 75465 4000 70307 8000 65501 16000 61024 32000 56853 64000 52967 96000 50818 144000 48757 216000 46779 324000 44881 486000 43060 729000 41313 1000000 40000 For a typical material, the table and the graph above (S-N curve) show the relationship between the magnitudes Sr and the number of stress reversals (N) before failure of the part. For example, if the part were subjected to Sr= 81,000 psi, then it would fail after N=1000 stress reversals. If the same part is subjected to Sr = 61,024 psi, then it can survive up to N=16,000 reversals, and so on. Sengupta MET 301: Design for Cyclic Loading 1 of 7 It has been observed that for most of engineering materials, the rate of reduction of Sr becomes negligible near the vicinity of N = 106 and the slope of the S-N curve becomes more or less horizontal. -
8 Safety Factors and Exposure Limits
8 Safety Factors and Exposure Limits Sven Ove Hansson 8.1 Numerical Decision Tools Numerical decision tools are abundantly employed in safety engineering. Two of the most commonly used tools are safety factors and exposure limits. A safety factor is the ratio of the maximal burden on a system not believed to cause damage to the highest allowed burden. An exposure limit is the highest allowed level of some potentially damaging exposure. 8.2 Safety Factors Humans have made use of safety reserves since prehistoric times. Builders and tool-makers have added extra strength to their constructions to be on the safe side. Nevertheless, the explicit use of safety factors in calculations seems to be of much later origin, probably the latter half of the nineteenth century. In the 1860s, the German railroad engineer A. Wohler recommended a factor of 2 for tension. In the early 1880s, the term “factor of safety” was in use, hence Rankine’s A Manual of Civil Engineering defined it as the ratio of the breaking load to the working load, and recommended different factors of safety for different materials (Randall, 1976). In structural engineering, the use of safety factors is now well established, and design criteria employing safety factors can be found in many engineering norms and standards. Most commonly, a safety factor is defined as the ratio of a measure of the maximum load not inducing failure to a corresponding measure of the load that is actually applied. In order to cover all the major integrity-threatening mechanisms that can occur, several safety factors may be needed. -
Energy-Based Design of Steel Structures According to the Predefined Interstory Drift Ratio†1
Digest 2012, December 2012, 1573-1593 Energy-based Design of Steel Structures According to the Predefined Interstory Drift Ratio†1 Onur MERTER* Özgür BOZDAĞ** Mustafa DÜZGÜN*** ABSTRACT The methods which take place in current building codes and used in seismic design of structures are generally linear elastic. Inelastic behavior of the structures under the effect of earthquake is considered indirectly in seismic design codes. Recent studies enable inelastic behavior of structures to be taken into account properly in the structural design. In this study, a calculation method oriented towards the design of new structures which fulfill the predefined interstory drift ratio according to the usage function of the structures was offered by considering the inelastic behavior of the structural members and by using the energy balance of the structures. Interstory drift ratios when the steel structure displacements reach the target displacements were compared with the initial interstory drift ratios and the results were interpreted. Keywords: Inelastic behavior, energy-based design, target displacement, performance based design. 1. INTRODUCTION Structures generally behave inelastic under excessive seismic loading. When earthquake loads which exceed the working load limits approach the lateral load capacity of the structures, stresses produced in structural members exceed elastic limits and displacements in structural elements become too large. Therefore, yield mechanisms of structures have a great importance in nonlinear structural behavior. Earthquake-resistant structures are designed by using displacement-based and energy-based methods in addition to force-based methods. In the force-based design methods, it is aimed that the capacity of structural members to be higher than the internal forces of the members under external loads. -
Safe Design of Shipping Packages Against Brittle Fracture
IAEA-TECDOC-717 Guidelines lor safe design of shipping packages against brittle fracture August 1993 FOREWORD ininte n th 1992h . meetin e Standinth f go g Advisory e GrouSafth en pTransporo f o t Radioactive Materials recommende publicatioe dth f thino s TECDO efforn a Cn promoto i t t e the widest debat criterie brittle th th r n eeo a fo fracture safe desig f transporno t packagese Th . published I AHA advice on the influence of brittle fracture on material integrity is contained in Appendix IX of the Advisory Material for the IAEA Regulations for the Safe Transport of Radioactive Material (1985 Edition, as amended 1990). Safety Series No. 37. This guidance is limited in scope, dealing only with ferritic steels in general terms. It is becoming more common for designers to specify materials other than austenitic stainless steel for packaging components date ferritin Th ao . c steels canno assumee b t applo dt otheo yt r metals, hence the need for further guidance on the development of relationships describing material properties at low temperatures. methode Th s describe thin di s TECDOC wil consideree b l Revisioe th y db n Paner fo l inclusio e 1996th n ni Editio IAEe th f Ano Regulation Safe th er Transporsfo f Radioactivo t e Materiasupportine th d an l g documents f accepteI .Revisioe th y db n Panel, this advice will candidata e b upgradinr efo Safeta o gt y Practice interie th n I m. period, this TECDOC offers provisional advice on brittle fracture evaluation. -
Specification for the Design, Testing, and Utilization of Industrial Steel Storage Racks - 1997 Edition Published by Rack Manufacturers Institute
Missouri University of Science and Technology Scholars' Mine Wei-Wen Yu Center for Cold-Formed Steel Rack Manufacturers Institute Structures 01 Nov 1999 Specification for the Design, esting,T and Utilization of Industrial Steel Storage Racks Rack Manufacturers Institute Follow this and additional works at: https://scholarsmine.mst.edu/ccfss-rmi Part of the Structural Engineering Commons Recommended Citation Rack Manufacturers Institute, "Specification for the Design, esting,T and Utilization of Industrial Steel Storage Racks" (1999). Rack Manufacturers Institute. 1. https://scholarsmine.mst.edu/ccfss-rmi/1 This Technical Report is brought to you for free and open access by Scholars' Mine. It has been accepted for inclusion in Rack Manufacturers Institute by an authorized administrator of Scholars' Mine. This work is protected by U. S. Copyright Law. Unauthorized use including reproduction for redistribution requires the permission of the copyright holder. For more information, please contact [email protected]. Specification for the Design, Testing, and Utilization of Industrial Steel Storage Racks - 1997 Edition Published By Rack Manufacturers Institute Specification for the Design, Testing and Utilization of Industrial Steel Storage Racks The Alliance of Material Handling Equipment, Systems, and Service Providers © 1997 Rack Manufacturers Institute PREFACE RACK MANUFACTURERS INSTITUTE The Rack Manufacturers Institute (RMI) is an independent incorporated trade association affiliated with the Material Handling Industry. The membership of RMI is made up of companies which produce the preponderance of industrial storage racks. MATERIAL HANDLING INDUSTRY Material Handling Industry (Industry) provides RMI with certain services and, in connection with this Specification, arranges for its production and distribution. Neither Material Handling Industry, its officers, directors, nor employees have any other participation in the development and preparation of the information contained in the Specification. -
Guide to Verifying Safety-Critical Structures for Reusable Launch and Reentry Vehicles
Guide to Verifying Safety-Critical Structures for Reusable Launch and Reentry Vehicles Version 1.0 November 2005 HQ-033805 Guide to Verifying Safety-Critical Structures for Reusable Launch and Reentry Vehicles Version 1.0 November 2005 Federal Aviation Administration Commercial Space Transportation 800 Independence Avenue, SW, Room 331 Washington, DC 2059 NOTICE Use of trade names or the names manufacturers or professional associations in this document does not constitute an official endorsement of such products, manufacturers, or associations, either expressed or implied, by the Federal Aviation Administration. TABLE OF CONTENTS 1.0 INTRODUCTION ...........................................................................................................1 1.1 Purpose ..........................................................................................................................1 1.2 Scope .............................................................................................................................1 1.3 Acronyms.......................................................................................................................1 1.4 Definitions .....................................................................................................................2 2.0 GENERAL RECOMMENDATIONS: STRUCTURAL AND MECHANICAL VERIFICATION.......................................................................................................................4 2.1 General Structural Systems Recommendations...............................................................4 -
ECSS-E-ST-32-10C Rev.1 6 March 2009
Downloaded from http://www.everyspec.com ECSS-E-ST-32-10C Rev.1 6 March 2009 Space engineering Structural factors of safety for spaceflight hardware ECSS Secretariat ESA-ESTEC Requirements & Standards Division Noordwijk, The Netherlands Downloaded from http://www.everyspec.com ECSSEST3210CRev.1 6March2009 Foreword This Standard is one of the series of ECSS Standards intended to be applied together for the management, engineering and product assurance in space projects and applications. ECSS is a cooperative effort of the European Space Agency, national space agencies and European industry associationsforthepurposeofdevelopingandmaintainingcommonstandards.Requirementsinthis Standardaredefinedintermsofwhatshallbeaccomplished,ratherthanintermsofhowtoorganize and perform the necessary work. This allows existing organizational structures and methods to be appliedwheretheyareeffective,andforthestructuresandmethodstoevolveasnecessarywithout rewritingthestandards. This Standard has been prepared by the ECSSEST3210C Working Group, reviewed by the ECSS ExecutiveSecretariatandapprovedbytheECSSTechnicalAuthority. Disclaimer ECSSdoesnotprovideanywarrantywhatsoever,whetherexpressed,implied,orstatutory,including, butnotlimitedto,anywarrantyofmerchantabilityorfitnessforaparticularpurposeoranywarranty that the contents of the item are errorfree. In no respect shall ECSS incur any liability for any damages,including,butnotlimitedto,direct,indirect,special,orconsequentialdamagesarisingout of,resultingfrom,orinanywayconnectedtotheuseofthisStandard,whetherornotbasedupon -
Introduction to Eurocodes Ec 0, 1, 2, 3 & 5
A&B Intro2Eurocode 2016 1 INTRODUCTION TO EUROCODES EC 0, 1, 2, 3 & 5 Dr Martin Cullen Associate Dean International You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) A&B Intro2Eurocode 2016 2 Objectives • What are Eurocodes? • Defining limit state design concept. • Structural design parameters • Design Loads or actions? • National annex • Factors of safety • Combination of loads. • Defining structural constraints (use, durability, environmental conditions, etc.) • Structural design examples of a simple elements. • Summary You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) A&B Intro2Eurocode 2016 3 What are EUROCODES? • Historically British Standards, German Standards, French Standards, etc. Not ideal for free trade within the European Union, so standardisation necessary. • Objectives • “The Eurocodes to establish a set of common technical rules for the design of buildings and civil engineering works which will ultimately replace the different rules in the various Member States.” • Special agreement (BC/CEN/03/89) • Council Directives on Public Procurement (71/305) • The Construction Products Directive (CPD) You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) A&B Intro2Eurocode 2016 4 What is the CPD? • The necessity to have commonality of structural materials irrespective of the source country or the destination country. • Six Essential Requirements -
Load and Resistance Factor Design
Load and Resistance Factor Design THEODORE V. GALAMBOS Load and Resistance Factor Design, abbreviated as LRFD, ample, beam theory is more accurate than column theory is a scheme of designing steel structures and structural (e.g., in Ref. 1,0 = 0.85 for beams and 0 = 0.75 for col components which is different from the traditionally used umns), or that the uncertainties of the dead load are smaller allowable stress format, as can be seen by comparing the than those of the live load (e.g., in Ref. 2, yD = 1.2 and 7^ following two inequalities: = 1.6). LRFD thus has the potential of providing more consistency, simply because it uses more than one factor. Rn/F.S. > ±Qm (1) The purpose of this paper is to describe the development 1 of an LRFD specification for steel structures. 4>Rn > t yiQni (2) SIMPLIFIED PROBABILISTIC MODEL 1 The strength R of a structural member and the load effect The first of these inequalities represents the allowable stress Q are both random parameters, since their actual values case, while the second represents the LRFD design crite cannot be determined with certainty (Fig. 1). The strength rion. The left side in each case is the design strength, and of a structure, often referred to also as its resistance, is de the right is the required strength* The term R defines the n fined in a popular sense as the maximum force that it can normal strength as given by an equation in a specification, sustain before it fails. Since failure is a term tfrat is associ and Q i is the load effect (i.e., a computed stress or a force n ated with collapse, it is more useful, in the context of such as bending moment, shear force axial force, etc.) de structural behavior, to define strength as the force under termined by structural analysis for the loads acting on the which a clearly defined limit state is attained. -
Chapter 11. Serviceability State Design
CHAPTER 11 SERVICEABILITY LIMIT STATE DESIGN Article 49. Cracking Limit State 49.1 General considerations In the case of verifications relating to Cracking Limit State, the effects of actions comprise the tensions in the sections (σ) and the crack openings (w) that they cause, as applicable. Generally, both σ and w are calculated from the design actions and the combinations indicated in Chapter 3 for Limit Serviceability States. The stresses shall be obtained from the actions, as indicated in Chapter 5. The tensions, crack openings and other verifying criteria, shall be calculated in accordance with the requirements indicated in the following paragraphs. 49.2 Cracking due to perpendicular stresses 49.2.1 Appearance of compression cracks In all persistent situations and in temporary situations with the least favourable combination of actions corresponding to the phase considered, the compressive stresses in the concrete shall satisfy the following: σc ≤ 0.60 f ck,j in which: σc Compressive stress of the concrete in the verifying situation. f ck,j Assumed value in the design for characteristic strength at j days (age of the concrete and the phase considered). 49.2.2 Decompression Limit State The calculations for the Decompression Limit State comprise verifying that under the combination of actions corresponding to the phase being studied, decompression does not occur in the concrete in any fibre in the section. 49.2.3 Cracking due to tension. Verifying criteria The general verifying of the Cracking Limit State due to tension comprises satisfying the following inequality: w k ≤ w max in which: wk Characteristic crack opening. -
The Serviceability of Resilient Seismic Design in New Zealand
17th U.S.-Japan-New Zealand Workshop on the Improvement of Structural Engineering and Resilience THE SERVICEABILITY OF RESILIENT SEISMIC DESIGN IN NEW ZEALAND Didier Pettinga Holmes Consulting LP Christchurch, New Zealand Abstract As with many seismic design codes around the world, the application of New Zealand seismic provisions has developed a focus on designing to Life-Safety, otherwise known as Ultimate Limit State (ULS) design. Typical New Zealand design practice sees the ULS lateral design completed first, with drift checks under applied Serviceability Limit State (SLS1) demands following. Recent New Zealand experience following the February 22nd 2011 Christchurch has demonstrated that the primary lateral system ULS performance is satisfactorily met by modern design, yet other smaller earthquake events have left some uncertainty as whether we are achieving consistently appropriate serviceability performance. Japanese Building Standard Law and the California Performance-Based Seismic Design approaches dictate quite different applications of a two-tiered limit-state design, with serviceability design preceding Life-Safety or Collapse-Prevention checks respectively. Based on observations following recent earthquakes in Japan, there is evidence that this approach produces a more resilient building- stock that not only meets serviceability criteria, but also drives better performance under larger levels of ground motion. A revision of the New Zealand SLS1 hazard definition, or conversely more rigorous or stringent allowances for applying reductions to the ULS design spectrum, would arguably provide a more resilient building-stock. While this might appear to be a brute-force approach to improving seismic resilience, the comparatively good performance of buildings in recent Japan earthquakes centred near major urban areas suggests this is a very reliable and penetrative means to improving seismic performance of buildings.